Search NASA⌕ Search

SEARCH · Search NASA

Results for “Calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Phase Calibration of Antenna Arrays Aimed at Spacecraft

A document describes a method of calibrating phase differences among ground antennas in an array so that the maximum-intensity direction of the far-field interference pattern of the array coincides with the direction for aiming the antennas to enable radio communication with a distant spacecraft. The method pertains to an array typically comprising between two and four 34-m (or similar size) antennas. The antennas are first calibrated pair-wise to maximize the uplink power received at a different spacecraft that is close enough for communication via a single ground antenna. In the calibration procedure, the phase of the signal transmitted by one of the antennas is ramped through a complete cycle, thereby causing the interference pattern to sweep over this closer spacecraft and guaranteeing that, at some point during the sweep, this spacecraft is illuminated at maximum intensity. The varying received uplink power is measured by a receiver in the closer spacecraft and the measurement data are transmitted to a ground station to enable determination of the optimum phase adjustment for the direction to the closer spacecraft. This adjustment is then translated to the look direction of the distant spacecraft, which could not be reached effectively using only one antenna.

Vilnrotter, Victor↗

A direct detection method of galaxy intrinsic ellipticity-gravitational shear correlation in non-linear regimes using self-calibration

Intrinsic alignment (IA) of galaxies is a challenging source of contamination in the Cosmic shear (GG) signals. The galaxy intrinsic ellipticity-gravitational shear (IG) correlation is generally the most dominant component of such contamination for cross-correlating redshift bins. One of the most effective techniques to mitigate such contamination is the self-calibration (SC) method which extracts the IG correlation and allows for its removal from the GG signal. In a photometric survey, the SC method first extracts the galaxy number density-galaxy intrinsic ellipticity (gI) correlation from the observed galaxy-galaxy lensing correlation using the redshift dependence of lens-source pairs. The IG correlation is computed through a scaling relation using the gI correlation and other lensing observables. The applicability of the SC method has so far been focused on the linear IA scales and the linear galaxy bias. We extend the SC method beyond the linear regime by modifying its scaling relation which can account for the non-linear galaxy bias model and various IA models. In this study, we provide a framework to detect the IG correlation for the redshift bins for source galaxies for the proposed year 1 survey of the Rubin Legacy Survey of Space and Time (LSST Y1). We tested the method for the tidal alignment and tidal torquing (TATT) model of IA and we found that the scaling relation is accurate within 10% and 20% for cross-correlating and auto-correlating redshift bins, respectively. Hence the suppression of IG contamination in observed GG correlation can be accomplished with a factor of 10 and 5, for cross-correlating and auto-correlating redshift bins, respectively. We tested the method's robustness and found that the suppression of IG contamination by a factor of 5 is still achievable for all combinations of cross-correlating bins even with the inclusion of a moderate amount of uncertainties on IA and bias parameters, respectively. We also make available, a branch of the code FAST-PT to provide gI correlations up to 1-loop order term used by the new SC method.

gravitational lensing↗

AI-assisted detector design for the EIC (AID(2)E)

Artificial Intelligence is poised to transform the design of complex, large-scale detectors like ePIC at the future Electron Ion Collider. Featuring a central detector with additional detecting systems in the far forward and far backward regions, the ePIC experiment incorporates numerous design parameters and objectives, including performance, physics reach, and cost, constrained by mechanical and geometric limits. This project aims to develop a scalable, distributed AI-assisted detector design for the EIC (AID(2)E), employing state-of-the-art multiobjective optimization to tackle complex designs. Supported by the ePIC software stack and using G EANT 4 simulations, our approach benefits from transparent parameterization and advanced AI features. The workflow leverages the PanDA and iDDS systems, used in major experiments such as ATLAS at CERN LHC, the Rubin Observatory, and sPHENIX at RHIC, to manage the compute intensive demands of ePIC detector simulations. Tailored enhancements to the PanDA system focus on usability, scalability, automation, and monitoring. Ultimately, this project aims to establish a robust design capability, apply a distributed AI-assisted workflow to the ePIC detector, and extend its applications to the design of the second detector (Detector-2) in the EIC, as well as to calibration and alignment tasks. Additionally, we are developing advanced data science tools to efficiently navigate the complex, multidimensional trade-offs identified through this optimization process.

97 MATHEMATICS AND COMPUTING↗

A radiation quality correction factor k{sub Q} for well-type ionization chambers for the measurement of the reference air kerma rate of {sup 60}Co HDR brachytherapy sources

Purpose: The aim of this study was to investigate whether a chamber-type-specific radiation quality correction factor k{sub Q} can be determined in order to measure the reference air kerma rate of {sup 60}Co high-dose-rate (HDR) brachytherapy sources with acceptable uncertainty by means of a well-type ionization chamber calibrated for {sup 192}Ir HDR sources. Methods: The calibration coefficients of 35 well-type ionization chambers of two different chamber types for radiation fields of {sup 60}Co and {sup 192}Ir HDR brachytherapy sources were determined experimentally. A radiation quality correction factor k{sub Q} was determined as the ratio of the calibration coefficients for {sup 60}Co and {sup 192}Ir. The dependence on chamber-to-chamber variations, source-to-source variations, and source strength was investigated. Results: For the PTW Tx33004 (Nucletron source dosimetry system (SDS)) well-type chamber, the type-specific radiation quality correction factor k{sub Q} is 1.19. Note that this value is valid for chambers with the serial number, SN ≥ 315 (Nucletron SDS SN ≥ 548) onward only. For the Standard Imaging HDR 1000 Plus well-type chambers, the type-specific correction factor k{sub Q} is 1.05. Both k{sub Q} values are independent of the source strengths in the complete clinically relevant range. The relative expanded uncertainty (k = 2) of k{sub Q} is U{sub k{sub Q}} = 2.1% for both chamber types. Conclusions: The calibration coefficient of a well-type chamber for radiation fields of {sup 60}Co HDR brachytherapy sources can be calculated from a given calibration coefficient for {sup 192}Ir radiation by using a chamber-type-specific radiation quality correction factor k{sub Q}. However, the uncertainty of a {sup 60}Co calibration coefficient calculated via k{sub Q} is at least twice as large as that for a direct calibration with a {sup 60}Co source.

60 APPLIED LIFE SCIENCES↗

AERONET-OC: Strengths and Weaknesses of a Network for the Validation of Satellite Coastal Radiometric Products

The Ocean Color component of the Aerosol Robotic Network (AERONET-OC) has been implemented to support long-term satellite ocean color investigations through cross-site consistent and accurate measurements collected by autonomous radiometer systems deployed on offshore fixed platforms. The ultimate purpose of AERONET-OC is the production of standardized measurements performed at different sites with identical measuring systems and protocols, calibrated using a single reference source and method, and processed with the same code. The AERONET-OC primary data product is the normalized water leaving radiance determined at center-wavelengths of interest for satellite ocean color applications, with an uncertainty lower than 5% in the blue-green spectral regions and higher than 8% in the red. Measurements collected at 6 sites counting the northern Adriatic Sea, the Baltic Proper, the Gulf of Finland, the Persian Gulf, and, the northern and southern margins of the Middle Atlantic Bay, have shown the capability of producing quality assured data over a wide range of bio-optical conditions including Case-2 yellow substance- and sedimentdominated waters. This work briefly introduces network elements like: deployment sites, measurement method, instrument calibration, processing scheme, quality-assurance, uncertainties, data archive and products accessibility. Emphases is given to those elements which underline the network strengths (i.e., mostly standardization of any network element) and its weaknesses (i.e., the use of consolidated, but old-fashioned technology). The work also addresses the application of AERONET-OC data to the validation of primary satellite radiometric products over a variety of complex coastal waters and finally provides elements for the identification of new deployment sites most suitable to support satellite ocean color missions.

Zibordi, Giuseppe↗

Technique for Radiometer and Antenna Array Calibration with a Radiated Noise Diode

This paper presents a new technique to calibrate a microwave radiometer and antenna array system. This calibration technique uses a radiated noise source in addition to two calibration sources internal to the radiometer. The method accurately calibrates antenna arrays with embedded active devices (such as amplifiers) which are used extensively in active phased array antennas.

Srinivasan, Karthik↗

The CMS Phase-1 Pixel Detector Upgrade

The CMS detector at the CERN LHC features a silicon pixel detector as its innermost subdetector. The original CMS pixel detector has been replaced with an upgraded pixel system (CMS Phase-1 pixel detector) in the extended year-end technical stop of the LHC in 2016/2017. The upgraded CMS pixel detector is designed to cope with the higher instantaneous luminosities that have been achieved by the LHC after the upgrades to the accelerator during the first long shutdown in 2013–2014. Compared to the original pixel detector, the upgraded detector has a better tracking performance and lower mass with four barrel layers and three endcap disks on each side to provide hit coverage up to an absolute value of pseudorapidity of 2.5. This paper describes the design and construction of the CMS Phase-1 pixel detector as well as its performance from commissioning to early operation in collision data-taking.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation and Optimizing Groundwater Investigations, Conceptual Design Analysis, Model Calibration and Remedial Design Using Parallel Numerical Methods: Theory and Application - 16578

Optimization of environmental restoration efforts at complex groundwater sites involves the development of a conceptual and often numerical flow and transport models. Typically, a limited number of simulations are done to assess the impact of parameter uncertainty, to evaluate remedial alternatives and develop a remedy, or to modify an existing remedy. A limited number of simulations are performed because each simulation can take upwards of several hours per simulation and until now the ability to conduct the 100's to 1000's of simulations needed to derive an optimal remedy was beyond the reach of the everyday practitioner. HGL has developed and implemented new parallel simulation and optimization methods in their software and has successfully deployed applications on high performance Cloud-based computing platforms. This advancement removes the impediment of burdensome and unpredictable runtime requirements these types of projects have typically exhibited using heuristic trial-and-error or even automated serial computation approaches. A parallel numerical solver has been added to the subsurface flow and transport simulator MODFLOW-SURFACT{sup TM} and has demonstrated reductions in solution time by as much as a factor of 9.8. This is accomplished by distributing the numerical computations of every time step over multiple processors. The integrated parallel simulation and optimization method uses the breadth and depth search approach; iteratively producing sets of tens or 100's of candidate solutions that are evaluated concurrently instead sequentially (i.e. one model evaluation at a time). Solutions within 80-100% of the globally optimal solution are regularly found expending only 5-10% of the usual computational effort using this new parallel optimization method (reducing computation effort by 10 to 20 times). Distributing optimal search runs across multiple processors additionally reduces calendar time to solutions. Practitioners evaluating multiple conceptual site models, model calibration by auto-calibration methods and remedial design by heuristics can enjoy significant reductions in model solution time by using the parallel numerical matrix solver in the physics-based simulator. Combining investigation and design analysis with breadth and depth parallel optimization methods, projects at the fringe of practical optimization, along with projects that were beyond the reach of formal optimization methods are now wholly feasible and tractable optimization problems. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Clumped 13 CH 2 D and 12 CHD 2 compositions of methyl groups from wood and synthetic monomers: Methods, experimental and theoretical calibrations, and initial results

Methyl groups are found in numerous biogenic and synthetic materials including geologically preserved materials such as wood. The carbon and hydrogen isotope compositions of methyl groups are used as tracers in biogeochemical cycles, as paleothermometers, and to determine the hydrogen isotopic composition of ancient rain. Here we present analyses of resolved 13 C–D ( 13 CH 2 D) and D–D ( 12 CHD 2 ) clumped isotope compositions of methyl groups as new variables for the study of methyl groups in the present and past. We first present chemical methods to extract, purify, and derivatize methyl groups from methoxyl (R–O–CH 3 ) groups as CH 3 F and CH 3 Cl, and high-resolution mass spectrometric techniques to determine the clumped isotope compositions of these species. We achieve precisions for 13 C–D clumping of ±0.25‰ and D–D clumping of ±2.5‰. We anchor our clumped isotopic measurements to a thermodynamic reference frame by first calculating the theoretical temperature dependences of 13 C–D and D–D clumping in CH 3 Cl, then placing our measurements onto this reference frame through experimental internal isotopic equilibration of CH 3 Cl at 200 °C. Finally, we provide and analyze an initial dataset of clumped 13 C–D and D–D compositions of methyl groups from various commercial/synthetic monomers and environmental woods. We observe ranges in clumped isotope compositions of ~11‰ in 13 C–D and ~48‰ in D–D, and systematic differences within these ranges between methyl groups from commercial monomers and wood. Specifically, commercial clumped 13 C–D compositions are between 0 and 3‰, which correspond to apparent equilibrium temperatures between 170 °C and the infinite temperature limit. In contrast, the clumped 13 C–D compositions of wood methoxyl groups are distinctively high (9.50–11.25‰) and 3–6‰ higher than would be expected if formed in internal isotopic equilibrium at Earth-surface temperatures. Commercial/synthetic methyl and wood methoxyl clumped D–D compositions are also distinct: -5 to +13‰ in commercial monomers vs. -35 to -8‰ in wood—such negative values cannot result from formation in isotopic equilibrium and require kinetic processes to have occurred. Overall, these results indicate that wood methoxyl groups are formed out of isotopic equilibrium and that clumped isotope compositions of methyl groups may be useful tracers of methyl group sources and sinks in the environment. For instance, isotopic clumping in methyl groups may be useful for understanding controls on isotopic clumping in methane produced by methylotrophic methanogens.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-D-204-01: Dual-Energy Calibration for Breast Density Measurement Using Spectral Mammography

Purpose: To investigate the feasibility of minimizing the systematic errors in dual-energy breast density quantification induced by the use of tissue-equivalent plastic phantoms as the calibration basis materials. Methods: Dual-energy calibration using tissue-equivalent plastic phantoms was performed on a spectral mammography system based on scanning multi-slit Si strip photon-counting detectors. The plastic phantom calibration used plastic water and adipose-equivalent phantoms as the basis materials, which have different x-ray attenuation properties compared to water and lipid in actual breast tissue. Two methods were used to convert the dual-energy decomposition measurements in plastic phantom thicknesses into true water and lipid basis. The first method was based entirely on the theoretical x-ray attenuation coefficients of the investigated materials in the mammographic energy range. The conversion matrix was determined from least-squares fitting of the target material using the reported attenuation coefficients of water and lipid. The second method was developed based on experimental calibrations, which measured the low-and high-energy signals of pure water and lipid of known thicknesses. A non-linear rational function was used to correlate the decomposed thicknesses to the known values, so that the conversion coefficients can be determined. Both methods were validated using independent measurements of water and lipid mixture phantoms. The correlation of the dual-energy decomposition measurements and the known values were studied with linear regression analysis. Results: There was an excellent linear correlation between the converted water thicknesses and the known values. The slopes of the linear fits were determined to be 0.63 and 1.03 for the simulation and experimental results, respectively. The non-linear fitting in the experimental approach reduced the root-mean-square (RMS) errors from approximately 3.4 mm to 1.5 mm. Conclusion: The results suggested that conversion of the dual-energy measurements into water and lipid thicknesses minimized the systematic errors in tissue decomposition studies.

60 APPLIED LIFE SCIENCES↗

Photometric Calibration of Consumer Video Cameras

Equipment and techniques have been developed to implement a method of photometric calibration of consumer video cameras for imaging of objects that are sufficiently narrow or sufficiently distant to be optically equivalent to point or line sources. Heretofore, it has been difficult to calibrate consumer video cameras, especially in cases of image saturation, because they exhibit nonlinear responses with dynamic ranges much smaller than those of scientific-grade video cameras. The present method not only takes this difficulty in stride but also makes it possible to extend effective dynamic ranges to several powers of ten beyond saturation levels. The method will likely be primarily useful in astronomical photometry. There are also potential commercial applications in medical and industrial imaging of point or line sources in the presence of saturation.This development was prompted by the need to measure brightnesses of debris in amateur video images of the breakup of the Space Shuttle Columbia. The purpose of these measurements is to use the brightness values to estimate relative masses of debris objects. In most of the images, the brightness of the main body of Columbia was found to exceed the dynamic ranges of the cameras. A similar problem arose a few years ago in the analysis of video images of Leonid meteors. The present method is a refined version of the calibration method developed to solve the Leonid calibration problem. In this method, one performs an endto- end calibration of the entire imaging system, including not only the imaging optics and imaging photodetector array but also analog tape recording and playback equipment (if used) and any frame grabber or other analog-to-digital converter (if used). To automatically incorporate the effects of nonlinearity and any other distortions into the calibration, the calibration images are processed in precisely the same manner as are the images of meteors, space-shuttle debris, or other objects that one seeks to analyze. The light source used to generate the calibration images is an artificial variable star comprising a Newtonian collimator illuminated by a light source modulated by a rotating variable neutral- density filter. This source acts as a point source, the brightness of which varies at a known rate. A video camera to be calibrated is aimed at this source. Fixed neutral-density filters are inserted in or removed from the light path as needed to make the video image of the source appear to fluctuate between dark and saturated bright. The resulting video-image data are analyzed by use of custom software that determines the integrated signal in each video frame and determines the system response curve (measured output signal versus input brightness). These determinations constitute the calibration, which is thereafter used in automatic, frame-by-frame processing of the data from the video images to be analyzed.

Suggs, Robert↗

Self-Calibrating and Remote Programmable Signal Conditioning Amplifier System and Method

A self-calibrating, remote programmable signal conditioning amplifier system employs information read from a memory attached to a measurement transducer for automatic calibration. The signal conditioning amplifier is self-calibrated on a continuous basis through use of a dual input path arrangement, with each path containing a multiplexer and a programmable amplifier. A digital signal processor controls operation of the system such that a transducer signal is applied to one of the input paths, while one or more calibration signals are applied to the second input path. Once the second path is calibrated, the digital signal processor switches the transducer signal to the second path. and then calibrates the first path. This process is continually repeated so that each path is calibrated on an essentially continuous basis. Dual output paths are also employed which are calibrated in the same manner. The digital signal processor also allows the implementation of a variety of digital filters which are either programmed into the system or downloaded by an operator, and performs up to eighth order linearization.

Medelius, Pedro J.↗

Highly accurate thickness measurement of multi-layered automotive paints using terahertz technology

In this contribution, we present a highly accurate approach for thickness measurements of multi-layered automotive paints using terahertz time domain spectroscopy in reflection geometry. The proposed method combines the benefits of a model-based material parameters extraction method to calibrate the paint coatings, a generalized Rouard's method to simulate the terahertz radiation behavior within arbitrary thin films, and the robustness of a powerful evolutionary optimization algorithm to increase the sensitivity of the minimum thickness measurement limit. Within the framework of this work, a self-calibration model is introduced, which takes into consideration the real industrial challenges such as the effect of wet-on-wet spray in the painting process.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Physics-constrained fault diagnosis framework for monitoring a standalone component of a thermal hydraulic system

A method for diagnosing faults includes receiving a description of a component of a thermal hydraulic system, where the description also indicates one or more sensors of the component. The method also includes constructing, based on a physical conservation law and using the description, a physics-based model describing operation of the component, the physics-based model including one or more unknown parameters. The method further includes calibrating the physics-based model by calculating the one or more unknown parameters using historical measurements to produce a calibrated model. Further, the method includes receiving sensor measurements captured by the one or more sensors, and calculating residuals corresponding to differences between measurements predicted by the calibrated model and the sensor measurements. The method also includes determining, based on the calculated residuals, a fault of the component or of a sensor of the one or more sensors, and generating an alert indicating the fault.

Nguyen, Tat Nghia↗

Dispersion calibration for the National Ignition Facility electron–positron–proton spectrometers for intense laser matter interactions

Electron–positron pairs, produced in intense laser–solid interactions, are diagnosed using magnetic spectrometers with image plates, such as the National Ignition Facility Electron–Positron–Proton Spectrometers (EPPSs). Although modeling can help infer the quantitative value, the accuracy of the models needs to be verified to ensure measurement quality. The dispersion of low-energy electrons and positrons may be affected by fringe magnetic fields near the entrance of the EPPS. We have calibrated the EPPS with six electron beams from a Siemens Oncor linear accelerator (linac) ranging in energy from 2.7 MeV to 15.2 MeV as they enter the spectrometer. A Geant4 Tool for Particle Simulation Monte Carlo simulation was set up to match depth dose curves and lateral profiles measured in water at 100 cm source–surface distance. An accurate relationship was established between the bending magnet current setting and the energy of the electron beam at the exit window. The simulations and measurements were used to determine the energy distributions of the six electron beams at the EPPS slit. Furthermore, analysis of the scanned image plates together with the determined energy distribution arriving in the spectrometer provides improved dispersion curves for the EPPS.

47 OTHER INSTRUMENTATION↗

Comparison of Spectral Radiance Calibration Techniques Used for Backscatter Ultraviolet Satellite Instruments

Methods for determining the absolute radiometric calibration sensitivities of backscatter ultraviolet (BUV) satellite instruments are compared as part of an effort to minimize pre-launch calibration errors. An internally illuminated integrating sphere source has been used for the Shuttle Solar BUV (SSBUV), Total Ozone Mapping Spectrometer (TOMS), Ozone Mapping Instrument (OMI), and Global Ozone Monitoring Experiment 2 (GOME-2) using standardized procedures traceable to national standards. These sphere-based sensitivities agree to within three percent [k equals 2] relative to calibrations performed using an external diffuser illuminated by standard irradiance sources, the customary radiance calibration method for BUV instruments. The uncertainty for these calibration techniques as implemented at the NASA Goddard Space Flight Centers Radiometric Calibration and Development Laboratory is shown to be 4 percent at 250nm [k equals 2] when using a single traceable calibration standard. Significant reduction in the uncertainty of nearly 1 percent is demonstrated when multiple calibration standards are used.

residual errors↗

Uncertainty Quantification for a Multi-phase Carbon Equation of State Model

Many physics models have tunable parameters that are calibrated by matching the model output to experimental or calculated data. However, given that calibration data often contain uncertainty and that different model parameter sets might result in a very similar simulated output for a finite calibration data set, it is advantageous to provide an ensemble of parameter sets that are consistent with the calibration data. Uncertainty quantification (UQ) provides a means to generate such an ensemble in a statistically rigorous fashion. In this work, we perform UQ for a multi-phase equation of state (EOS) model for carbon containing the diamond, graphite, and liquid phases. We use a Bayesian framework for the UQ and introduce a novel strategy for including phase diagram information in the calibration. The method is highly general and accurately reproduces the calibration data without any material-specific prior knowledge of the EOS model parameters.

36 MATERIALS SCIENCE↗