Search NASA⌕ Search

SEARCH · Search NASA

Results for “Calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

A GENERAL STUDY OF THE INFLUENCE OF CATASTROPHIC PHOTOMETRIC REDSHIFT ERRORS ON COSMOLOGY WITH COSMIC SHEAR TOMOGRAPHY

A goal of forthcoming imaging surveys is to use weak gravitational lensing shear measurements to constrain dark energy. A challenge to this program is that redshifts to the lensed, source galaxies must be determined using photometric, rather than spectroscopic, information. We quantify the importance of uncalibrated photometric redshift outliers to the dark energy goals of forthcoming imaging surveys in a manner that does not assume any particular photometric redshift technique or template. In so doing, we provide an approximate blueprint for computing the influence of specific outlier populations on dark energy constraints. We find that outlier populations whose photo-z distributions are tightly localized about a significantly biased redshift must be controlled to a per-galaxy rate of (1-3) x 10{sup -3} to insure that systematic errors on dark energy parameters are rendered negligible. In the complementary limit, a subset of imaged galaxies with uncalibrated photometric redshifts distributed over a broad range must be limited to fewer than a per-galaxy error rate of F {sub cat} {approx}< (2-4) x 10{sup -4}. Additionally, we explore the relative importance of calibrating the photo-z's of a core set of relatively well-understood galaxies as compared to the need to identify potential catastrophic photo-z outliers. We discuss the degradation of the statistical constraints on dark energy parameters induced by excising source galaxies at high- and low-photometric redshifts, concluding that removing galaxies with photometric redshifts z {sup ph} {approx}> 2.4 and z {sup ph} {approx}< 0.3 may mitigate damaging catastrophic redshift outliers at a relatively small ({approx}<20%) cost in statistical error. In an Appendix, we show that forecasts for the degradation in dark energy parameter constraints due to uncertain photometric redshifts depend sensitively on the treatment of the nonlinear matter power spectrum. In particular, previous work using Peacock and Dodds may have overestimated the photo-z calibration requirements of future surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Spectroscopic determination of thermal impulse in sub-second heating events using lanthanide-doped oxide precursors and phenomenological modeling

Using a mixture of crystalline-Ho:ZrO{sub 2}, precursor-Dy:Y{sub 2}O{sub 3}, and precursor-Eu:ZrO{sub 2} nanoparticles we develop thermal impulse sensors capable of measuring equivalent isothermal temperatures and durations during a heating event, with response times of <100 ms, and a temperature range of at least 673 K to 1173 K. In order to determine the temperature and duration from the sensors after the heating event we measure the sensors' fluorescence spectrum, which is then compared with lab based calibration data. By using two precursor materials with different reaction kinetics we are able to extract both temperature and duration. Based on blind sample testing we find that the sensors and calculation method are accurate for measuring temperature and duration, but currently suffer a lack of precision due to difficulties in producing homogeneously heated samples.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-677: Reproducibility of Production of Ionization Chambers

Purpose: To compare the reproducibility of the production of several cylindrical and plane-parallel chambers popular in Poland in terms of a calibration coefficient. Methods: The investigation was performed for PTW30013 (20 chambers), 30001 (10 chambers), FC65-G (17 chambers) cylindrical chambers and for PPC05 (14 chambers), Roos 34001 (8 chambers) plane parallel chambers. The calibration factors were measured at the same accredited secondary standard laboratory in terms of a dose to water. All the measurements were carried out at the same laboratory, by the same staff, in accordance with the same IAEA recommendations. All the chambers were calibrated in the Co60 beam. Reproducibility was described in terms of the mean value, its standard deviation and the ratio of the maximum and minimum value of calibration factors for each set of chambers separately. The combined uncertainty budged (1SD) calculated according to the IAEA-TECDOC-1585 of the calibration factor was of 0.25%. Results: The calibration coefficients for PTW30013, 30001, and FC65-G chambers were 5.36±0.03, 5.28±0.06, 4.79±0.015 nC/Gy respectively and for PPC05, and Roos chambers were 59±2, 8.3±0.1 nC/Gy respectively. The maximum/minimum ratio of calibration factors for PTW30013, 30001, FC65-G, and for PPC05, Roos chambers were 1.03, 1.03, 1.01, 1.14 and 1.03 respectively. Conclusion: The production of all ion chambers was very reproducible except the Markus type PPC05 for which the ratio of maximum/minimum calibration coefficients of 1.14 was obtained.

07 ISOTOPE AND RADIATION SOURCES↗

Self-calibrating the look-elsewhere effect: fast evaluation of the statistical significance using peak heights

In experiments where one searches a large parameter space for an anomaly, one often finds many spurious noise-induced peaks in the likelihood. This is known as the look-elsewhere effect, and must be corrected for when performing statistical analysis. Here, this paper introduces a method to calibrate the false alarm probability (FAP), or p-value, for a given dataset by considering the heights of the highest peaks in the likelihood. Specifically, we derive an equation relating the global p-value to the rank and height of local maxima. In the simplest form of self-calibration, the look-elsewhere-corrected $\chi^2$ of a physical peak is approximated by the $\chi^2$ of the peak minus the $\chi^2$ of the highest noise-induced peak, with accuracy improved by considering lower peaks. In contrast to alternative methods, this approach has negligible computational cost as peaks in the likelihood are a byproduct of every peak-search analysis. We apply to examples from astronomy, including planet detection, periodograms, and cosmology.

79 ASTRONOMY AND ASTROPHYSICS↗

Prime VI

SAND2025-03757O Prime VI is a distribution-of-disease outbreak model calibration code based on variational inference. It accompanies a publication for submission to Statistics in Medicine journal, and the code will be maintained for open-source use on Sandia's GitLab. The software provides methods for calibrating an epidemiological model to measured case-count data for a multitude of correlated spatial regions. The code solves a Bayesian inverse problem for model calibration where the posterior over-model parameters are approximated through a custom implementation of variational inference. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Safta, Cosmin↗

Let Each Quantum Bit Choose Its Basis Gates

Near-term quantum computers are primarily limited by errors in quantum operations (or gates) between two quantum bits (or qubits). A physical machine typically provides a set of basis gates that include primitive 2-qubit (2Q) and 1-qubit (1Q) gates that can be implemented in a given technology. 2Q entangling gates, coupled with some 1Q gates, allow for universal quantum computation. In superconducting technologies, the current state of the art is to implement the same 2Q gate between every pair of qubits (typically an XX-or XY-type gate). This strict hardware uniformity requirement for 2Q gates in a large quantum computer has made scaling up a time and resource-intensive endeavor in the lab. We propose a radical idea – allow the 2Q basis gate(s) to differ between every pair of qubits, selecting the best entangling gates that can be calibrated between given pairs of qubits. This work aims to give quantum scientists the ability to run meaningful algorithms with qubit systems that are not perfectly uniform. Scientists will also be able to use a much broader variety of novel 2Q gates for quantum computing. We develop a theoretical framework for identifying good 2Q basis gates on “nonstandard” Cartan trajectories that deviate from “standard” trajectories like XX. We then introduce practical methods for calibration and compilation with nonstandard 2Q gates, and discuss possible ways to improve the compilation. To demonstrate our methods in a case study, we simulated both standard XY-type trajectories and faster, nonstandard trajectories using an entangling gate architecture with far-detuned transmon qubits. We identify efficient 2Q basis gates on these nonstandard trajectories and use them to compile a number of standard benchmark circuits such as QFT and QAOA. Furthermore, our results demonstrate an 8x improvement over the baseline 2Q gates with respect to speed and coherence-limited gate fidelity.

quantum computing↗

Indications for Pelvic Nodal Treatment in Prostate Cancer Should Change. Validation of the Roach Formula in a Large Extended Nodal Dissection Series

Purpose: Previous studies have criticized the predicting ability of the Roach formula in assessing the risk of lymph node invasion (LNI) in contemporary patients with prostate cancer (PCa) due to a significant overestimation of LNI rates. However, all those studies included patients treated with limited pelvic lymph node dissection (PLND), which is associated with high rates of false negative findings. We hypothesized that the Roach formula is still an accurate tool for LNI predictions if an extended PLND (ePLND) is performed. Methods and Materials: We included 3,115 consecutive patients treated with radical prostatectomy and ePLND between 2000 and 2010 at a single tertiary referral center. Extended PLND consisted of removal of obturator, external iliac, and hypogastric lymph nodes. We externally validated the Roach formula by using the area under the receiver operating characteristics curve and calibration plot method. Moreover, we tested the performance characteristics of different formula-generated cutoff values ranging from 1% to 20%. Results: The accuracy of the Roach formula was 80.3%. The calibration showed only a minor underestimation of the LNI risk in high-risk patients (6.7%). According to the Roach formula, the use of 15% cut off would have allowed 74.2% (2,311/3,115) of patients to avoid nodal irradiation, while up to 32.7% (111/336) of all patients with LNI would have been missed. When the cut off was lowered to 6%, nodal treatment would have been spared in 1,541 (49.5%) patients while missing 41 LNI patients. The sensitivity, specificity, and negative predictive values associated with the 6% cut off were 87.9%, 54%, and 97.3%, respectively. Conclusions: The Roach formula is still accurate and does not overestimate the rate of LNI in contemporary prostate cancer patients if they are treated with ePLND. However, the recommended cut off of 15% would miss approximately one-third of patients with LNI. Based on our results, the cut off should be lowered to 6%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Calibrating Synchronous-Generator-Interfaced DG Models in Microgrids Using Multiple Event Data

Microgrids, consisting of distributed generators (DGs), loads, and energy storage systems, play an important role in future smart grids. In order to evaluate how microgrids operate and their dynamic response, it is necessary to develop accurate dynamic models of DGs in microgrids. This paper proposes a systematic method to calibrate synchronous-generator-interfaced DG models. Challenges associated with model validation in microgrids are analyzed. Underlying parameters are categorized into two groups, i.e., the steady-state parameters and time constants, which are estimated in two successive stages using multiple event data. This methodology ensures that the validated model with the estimated parameters are applicable for all events. A modified unscented Kalman filter (UKF) is proposed to deal with the cases in which measurement of power angle is unavailable. The effectiveness of the proposed method is validated using field test data of a 2.6 MVA diesel generator in a real microgrid.

Wang, Zhiwen↗

Framework for large-scale relativistic simulations in the characteristic approach

We present a new computational framework (LEO) that enables us to carry out the very first large-scale, high-resolution computations in the context of the characteristic approach in numerical relativity. At the analytic level, our approach is based on a new implementation of the eth formalism, using a nonstandard representation of the spin-raising and spin-lowering angular operators in terms of nonconformal coordinates on the sphere; we couple this formalism to a partially first-order reduction (in the angular variables) of the Einstein equations. The numerical implementation of our approach supplies the basic building blocks for a highly parallel, easily extensible numerical code. We demonstrate the adaptability and excellent scaling of our numerical code by solving, within our numerical framework, for a scalar field minimally coupled to gravity (the Einstein-Klein-Gordon problem) in 3 dimensions. The nonlinear code is globally second-order convergent, and has been extensively tested using as a reference a calibrated code with the same initial and boundary data and radial marching algorithm. In this context, we show how accurately we can follow quasinormal mode ringing. In the linear regime, we show energy conservation for a number of initial data sets with varying angular structure. A striking result that arises in this context is the saturation of the flow of energy through the Schwarzschild radius. As a final calibration check, we perform a large simulation with resolution never achieved before.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Clinical introduction of image lag correction for a cone beam CT system

Purpose: Image lag in the flat-panel detector used for Linac integrated cone beam computed tomography (CBCT) has a degrading effect on CBCT image quality. The most prominent visible artifact is the presence of bright semicircular structure in the transverse view of the scans, known also as radar artifact. Several correction strategies have been proposed, but until now the clinical introduction of such corrections remains unreported. In November 2013, the authors have clinically implemented a previously proposed image lag correction on all of their machines at their main site in Amsterdam. The purpose of this study was to retrospectively evaluate the effect of the correction on the quality of CBCT images and evaluate the required calibration frequency. Methods: Image lag was measured in five clinical CBCT systems (Elekta Synergy 4.6) using an in-house developed beam interrupting device that stops the x-ray beam midway through the data acquisition of an unattenuated beam for calibration. A triple exponential falling edge response was fitted to the measured data and used to correct image lag from projection images with an infinite response. This filter, including an extrapolation for saturated pixels, was incorporated in the authors’ in-house developed clinical CBCT reconstruction software. To investigate the short-term stability of the lag and associated parameters, a series of five image lag measurement over a period of three months was performed. For quantitative analysis, the authors have retrospectively selected ten patients treated in the pelvic region. The apparent contrast was quantified in polar coordinates for scans reconstructed using the parameters obtained from different dates with and without saturation handling. Results: Visually, the radar artifact was minimal in scans reconstructed using image lag correction especially when saturation handling was used. In patient imaging, there was a significant reduction of the apparent contrast from 43 ± 16.7 to 15.5 ± 11.9 HU without the saturation handling and to 9.6 ± 12.1 HU with the saturation handling, depending on the date of the calibration. The image lag correction parameters were stable over a period of 3 months. The computational load was increased by approximately 10%, not endangering the fast in-line reconstruction. Conclusions: The lag correction was successfully implemented clinically and removed most image lag artifacts thus improving the image quality. Image lag correction parameters were stable for 3 months indicating low frequency of calibration requirements.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Method for Producing Hierarchical and Statistically Calibrated Predictions of Nuclear Material Properties from Existing Models

Computer vision-based analysis of micrographs of nuclear materials is an emerging technique for property prediction, synthetic route identification, and other material analysis tasks. These analysis tasks play a pivotal role in many material characterization applications such as signature development for treaty verification, process optimization, etc. The backbone in many of the recent computer vision-based techniques is a deep learning model, which takes a fixed-size set of pixels and provides a class prediction for that set of pixels. For example, previous work developed a deep convolutional neural network (CNN) to predict the synthetic route from a 256 px x 256 px patch taken from a larger image of uranium ore concentrates. In this work, we present several methods for first calibrating these models in a manner that they can provide accurate probabilities of their predictions’ veracity, and several methods of combining these probabilities. Overall, the combination of these two steps into a pipeline allows for full-image and even full-sample (where a sample has many images) predictions with associated confidence values. Finally, we show that one can also use the patch predictions and confidence to produce a visualization to map predicted constituents through the image. Results and examples for predicting and mapping uranium ore concentrates’ synthetic process from imagery will be presented.

artificial intelligence↗

Calibration of higher eigenmodes of cantilevers

A method is presented for calibrating the higher eigenmodes (resonant modes) of atomic force microscopy cantilevers that can be performed prior to any tip-sample interaction. The method leverages recent efforts in accurately calibrating the first eigenmode by providing the higher-mode stiffness as a ratio to the first mode stiffness. A one-time calibration routine must be performed for every cantilever type to determine a power-law relationship between stiffness and frequency, which is then stored for future use on similar cantilevers. Then, future calibrations only require a measurement of the ratio of resonant frequencies and the stiffness of the first mode. This method is verified through stiffness measurements using three independent approaches: interferometric measurement, AC approach-curve calibration, and finite element analysis simulation. Power-law values for calibrating higher-mode stiffnesses are reported for several cantilever models. Once the higher-mode stiffnesses are known, the amplitude of each mode can also be calibrated from the thermal spectrum by application of the equipartition theorem.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of detection sensitivity for a Fiber Optic Intrusion Detection System (FOIDS) using design of experiments.

The Fiber Optic Intrusion Detection System (FOIDS)1 is a physical security sensor deployed on fence lines to detect climb or cut intrusions by adversaries. Calibration of detection sensitivity can be time consuming because, for example, the FiberSenSys FD-332 has 32 settings that can be adjusted independently to provide a balance between a high probability of detection and a low nuisance alarm rate. Therefore, an efficient method of calibrating the FOIDS in the field, other than by trial and error, was needed. This study was conducted to: x Identify the most significant settings for controlling detection x Develop a way of predicting detection sensitivity for given settings x Develop a set of optimal settings for validation The Design of Experiments (DoE) 2-4 methodology was used to generate small, planned test matrixes, which could be statistically analyzed to yield more information from the test data. Design of Experiments is a statistical methodology for quickly optimizing performance of systems with measurable input and output variables. DoE was used to design custom screening experiments based on 11 FOIDS settings believed to have the most affect on WKH types of fence perimeter intrusions were evaluated: simulated cut intrusions and actual climb intrusions. Two slightly different two-level randomized fractional factorial designed experiment matrixes consisting of 16 unique experiments were performed in the field for each type of intrusion. Three repetitions were conducted for every cut test; two repetitions were conducted for every climb test. Total number of cut tests analyzed was 51; the total number of climb tests was 38. This paper discusses the results and benefits of using Design of Experiments (DoE) to calibrate and optimize the settings for a FOIDS sensor

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Enhancing Camera Calibration for Traffic Surveillance with an Integrated Approach of Genetic Algorithm and Particle Swarm Optimization

Recent advancements in sensor technologies, coupled with signal processing and machine learning, have enabled real-time traffic control systems to effectively adapt to changing traffic conditions. Cameras, as sensors, offer a cost-effective means to determine the number, location, type, and speed of vehicles, aiding decision-making at traffic intersections. However, the effective use of cameras for traffic surveillance requires proper calibration. This paper proposes a new optimization-based method for camera calibration. In this approach, initial calibration parameters are established using the Direct Linear Transformation (DLT) method. Then, optimization algorithms are applied to further refine the calibration parameters for the correction of nonlinear lens distortions. A significant enhancement in the optimization process is achieved through the integration of the Genetic Algorithm (GA) and Particle Swarm Optimization (PSO) into a combined Integrated GA and PSO (IGAPSO) technique. The effectiveness of this method is demonstrated through the calibration of eleven roadside cameras at three different intersections. The experimental results show that when compared to the baseline DLT method, the vehicle localization error is reduced by 22.30% with GA, 22.31% with PSO, and 25.51% with IGAPSO.

47 OTHER INSTRUMENTATION↗

Physics-constrained fault diagnosis framework for monitoring a multi-component thermal hydraulic system

A method for diagnosing faults includes receiving a system description of a thermal hydraulic system, the system description indicating a plurality of components and sensors. The method also includes constructing, based on physical conservations laws and using the system description, a plurality of physics-based models for the plurality of components, each of the plurality of physics-based models including unknown parameters. The method further includes receiving historical measurements and calibrating the physics-based models by calculating the unknown parameters of each of the physics-based models using the historical measurements to produce calibrated models. The method also includes receiving sensor measurements of the sensors, and calculating residuals corresponding to differences between measurements predicted by the plurality of calibrated models and the sensor measurements. The method also includes determining, based on the calculated residuals, a fault of a component or a sensor, and generating an alert indicating the fault.

Nguyen, Tat Nghia↗

Significantly Improving Regional Seismic Amplitude Tomography at Higher Frequencies by Determining S -Wave Bandwidth

Characterizing regional seismic signals continues to be a difficult problem due to their variability. Calibration of these signals is very important to many aspects of monitoring underground nuclear explosions, including detecting seismic signals, discriminating explosions from earthquakes, and reliably estimating magnitude and yield. Amplitude tomography, which simultaneously inverts for source, propagation, and site effects, is a leading method of calibrating these signals. A major issue in amplitude tomography is the data quality of the input amplitude measurements. Pre-event and prephase signal-to-noise ratio (SNR) tests are typically used but can frequently include bad signals and exclude good signals. The deficiencies of SNR criteria, which are demonstrated here, lead to large calibration errors. To ameliorate these issues, we introduce a semi-automated approach to assess the bandwidth of a spectrum where it behaves physically. We determine the maximum frequency (denoted as F max ) where it deviates from this behavior due to inflections at which noise or spurious signals start to bias the spectra away from the expected decay. We compare two amplitude tomography runs using the SNR and new F max criteria and show significant improvements to the stability and accuracy of the tomography output for frequency bands higher than 2 Hz by using our assessments of valid S-wave bandwidth. We compare Q estimates, P/S residuals, and some detailed results to explain the improvements. Lastly, for frequency bands higher than 4 Hz, needed for effective P/S discrimination of explosions from earthquakes, the new bandwidth criteria sufficiently fix the instabilities and errors so that the residuals and calibration terms are useful for application.

58 GEOSCIENCES↗

Numerical Study of Vortex Core in Turbulent Swirling Flow

Swirling flow has attracted a great deal of research interest. An application of swirling flow can be found in many engineering areas; such as gas cyclone and heat transfer enhancement. In nuclear engineering, swirling flow is used as heat transfer enhancement in rod bundle by installing grid spacer and mixing vane. Because of its extensive applications, there has been a great number of experimental and numerical investigations of swirling flow. McClusky et al., experimentally studied mapping of the lateral velocity in rod bundle using Laser Doppler Velocimetry (LDV) and Conner et al. predicted the flow field in rod bundle by CFD. To understand the characteristics of swirling flow such as tangential velocity and vortex core swirling flow, some researchers investigated swirling flow in a pipe instead of in rod bundle. This is due to the similarity between swirling flow in a pipe and rod bundle. In recent study, flow mapping of 2D velocity field of single-phase swirling flow had been conducted experimentally by Particle Image Velocimetry (PIV). However, this method needs calibration and complicated. The new measurement technique for flow mapping in swirling flow was done by phased array Ultrasonic Velocity Profiler (PAUVP). Hamdani et al., successfully plotted velocity field and determined the swirling core region (vortex core). This technique is nonintrusive and no need calibration. However, there was a limitation of the measurement because phased array UVP cannot capture 360 deg. velocity field inside the pipe. In addition, tangential velocity in CFD results was not agree well with experiment data due asymmetric problem. To evaluate this limitation of experimental method, the numerical simulations using Computational Fluid Dynamics (CFD) needs to be performed. The objective of this study is to use the commercial CFD code Fluent to model the developing turbulent swirling flow induced by twisted tape inside a straight pipe, and to gain an understanding of such a flow and the turbulence models involved in the simulation. Straight pipe is used instead of rod bundle for a simplification. In this work, the Renormalized Group (RNG) k-{epsilon} turbulence model and Reynolds Stress Model (RSM) turbulence model, are performed to study the phenomena of vortex core in a pipe with twisted tape inserts. Effects of the Reynolds number and asymmetric of twisted tape (inclination, {alpha} = 5 deg. and {alpha} = 20 deg.) on swirling core position are examined using water as the testing fluid. Furthermore, the Navier-Stokes equations will be solved to obtain results that can be validated with the previous experimental results. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Auto calibration of a cone-beam-CT

Purpose: This paper introduces a novel autocalibration method for cone-beam-CTs (CBCT) or flat-panel CTs, assuming a perfect rotation. The method is based on ellipse-fitting. Autocalibration refers to accurate recovery of the geometric alignment of a CBCT device from projection images alone, without any manual measurements. Methods: The authors use test objects containing small arbitrarily positioned radio-opaque markers. No information regarding the relative positions of the markers is used. In practice, the authors use three to eight metal ball bearings (diameter of 1 mm), e.g., positioned roughly in a vertical line such that their projection image curves on the detector preferably form large ellipses over the circular orbit. From this ellipse-to-curve mapping and also from its inversion the authors derive an explicit formula. Nonlinear optimization based on this mapping enables them to determine the six relevant parameters of the system up to the device rotation angle, which is sufficient to define the geometry of a CBCT-machine assuming a perfect rotational movement. These parameters also include out-of-plane rotations. The authors evaluate their method by simulation based on data used in two similar approaches [L. Smekal, M. Kachelriess, S. E, and K. Wa, 'Geometric misalignment and calibration in cone-beam tomography,' Med. Phys. 31(12), 3242-3266 (2004); K. Yang, A. L. C. Kwan, D. F. Miller, and J. M. Boone, 'A geometric calibration method for cone beam CT systems,' Med. Phys. 33(6), 1695-1706 (2006)]. This allows a direct comparison of accuracy. Furthermore, the authors present real-world 3D reconstructions of a dry human spine segment and an electronic device. The reconstructions were computed from projections taken with a commercial dental CBCT device having two different focus-to-detector distances that were both calibrated with their method. The authors compare their reconstruction with a reconstruction computed by the manufacturer of the CBCT device to demonstrate the achievable spatial resolution of their calibration procedure. Results: Compared to the results published in the most closely related work [K. Yang, A. L. C. Kwan, D. F. Miller, and J. M. Boone, 'A geometric calibration method for cone beam CT systems,' Med. Phys. 33(6), 1695-1706 (2006)], the simulation proved the greater accuracy of their method, as well as a lower standard deviation of roughly 1 order of magnitude. When compared to another similar approach [L. Smekal, M. Kachelriess, S. E, and K. Wa, 'Geometric misalignment and calibration in cone-beam tomography,' Med. Phys. 31(12), 3242-3266 (2004)], their results were roughly of the same order of accuracy. Their analysis revealed that the method is capable of sufficiently calibrating out-of-plane angles in cases of larger cone angles when neglecting these angles negatively affects the reconstruction. Fine details in the 3D reconstruction of the spine segment and an electronic device indicate a high geometric calibration accuracy and the capability to produce state-of-the-art reconstructions. Conclusions: The method introduced here makes no requirements on the accuracy of the test object. In contrast to many previous autocalibration methods their approach also includes out-of-plane rotations of the detector. Although assuming a perfect rotation, the method seems to be sufficiently accurate for a commercial CBCT scanner. For devices which require higher dimensional geometry models, the method could be used as a initial calibration procedure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗