Search NASA⌕ Search

SEARCH · Search NASA

Results for “Capacity Loss”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Automating Detection and Diagnosis of Faults, Failures, and Underperformance in PV Plants

The project developed hybrid physics-based and machine-learning methods for near-real-time detection of balance-of-system faults (e.g., string, combiner, and tracker outages) in utility-scale Photovoltaic plants, achieving over 50% true positive rates with under 10% false positives and significantly reducing engineering setup time. In the extended phase, the scope expanded to plant-level underperformance analysis and industry benchmarking through the SUPER.epri.com platform. SUPER standardizes data processing and performance metrics across more than 9 GWac and 120+ plants, enabling robust comparisons and insights into loss rates, inverter downtime, and capacity degradation.

14 SOLAR ENERGY↗

Analysis of cryogenic propellant logistics.

Large launch vehicle cryogenic propellant logistics including storage and production capacity optimization, cost and heat loss analyses by computer simulation

PROPELLANT STORAGE↗

Secondary iron-air batteries

Self discharge, capacity maintenance, oxidation, and water loss problems in secondary iron-air batteries

Wagner, O. C.↗

Acceptance Testing of a Satellite SCADA Photovoltaic-Diesel Hybrid System

Satellite Supervisory Control and Data Acquisition (SCADA) of a Photovoltaic (PV)/diesel hybrid system was tested using NASA's Advanced Communication Technology Satellite (ACTS) and Ultra Small Aperture Terminal (USAT) ground stations. The setup consisted of a custom-designed PV/diesel hybrid system, located at the Florida Solar Energy Center (FSEC), which was controlled and monitored at a "remote" hub via Ka-band satellite link connecting two 1/4 Watt USATs in a SCADA arrangement. The robustness of the communications link was tested for remote monitoring of the health and performance of a PV/diesel hybrid system, and for investigating load control and battery charging strategies to maximize battery capacity and lifetime, and minimize loss of critical load probability. Baseline hardware performance test results demonstrated that continuous two-second data transfers can be accomplished under clear sky conditions with an error rate of less than 1%. The delay introduced by the satellite (1/4 sec) was transparent to synchronization of satellite modem as well as to the PV/diesel-hybrid computer. End-to-end communications link recovery times were less than 36 seconds for loss of power and less than one second for loss of link. The system recovered by resuming operation without any manual intervention, which is important since the 4 dB margin is not sufficient to prevent loss of the satellite link during moderate to heavy rain. Hybrid operations during loss of communications link continued seamlessly but real-time monitoring was interrupted. For this sub-tropical region, the estimated amount of time that the signal fade will exceed the 4 dB margin is about 10%. These results suggest that data rates of 4800 bps and a link margin of 4 dB with a 1/4 Watt transmitter are sufficient for end-to-end operation in this SCADA application.

Kalu, A.↗

Utilizing Strain Rate Jump Testing to Predict Flow Formability of Al Alloys Sensitive to Portevin-Le Chatelier Instabilities

Predicting the flow formability of Al alloys is challenging due to the incremental deformation, complex loading path, and wide range of strain rates characteristic of the process. State-of-the-art research efforts have primarily focused on formability metrics derived from ambient temperature, constant strain rate uniaxial tensile testing. However, Al alloys in formable tempers tend to exhibit serrated Portevin-Le Chatelier (PLC) flow. The appearance of PLC instabilities implies a negative strain rate sensitivity, loss of tensile area reduction capacity, and decreased formability. Elevated temperature and interrupted strain rate tensile tests of relevant Al alloys were conducted to investigate the effects of rapid changes in strain rate (analogous to a forming increment by a passing roller) on common formability metrics. Emphasis was placed on the character/extent of PLC instabilities using digital image correlation strain measurements. The outcome of this work highlights the possibility of predicting flow formability using strain rate jump testing.

flow forming↗

Gigawatt-year nuclear-geothermal energy storage for light-water and high-temperature reactors

Capital-intensive, low-operating cost nuclear plants are most economical when operated under base-load conditions. However, electricity demand varies on a daily, weekly, and seasonal basis. In deregulated utility markets this implies high prices for electricity at times of high electricity demand and low prices for electricity at times of low electricity demand. We examined coupling nuclear heat sources to geothermal heat storage systems to enable these power sources to meet hourly to seasonal variable electricity demand. At times of low electricity demand the reactor heats a fluid that is then injected a kilometer or more underground to heat rock to high temperatures. The fluid travels through the permeable-rock heat-storage zone, transfers heat to the rock, is returned to the surface to be reheated, and re-injected underground. At times of high electricity demand the cycle is reversed, heat is extracted, and the heat is used to power a geothermal power plant to produce intermediate or peak power. When coupling geothermal heat storage with light-water reactors (LWRs), pressurized water (<300 deg. C) is the preferred heat transfer fluid. When coupling geothermal heat storage with high temperature reactors at higher temperatures, supercritical carbon dioxide is the preferred heat transfer fluid. The non-ideal characteristics of supercritical carbon dioxide create the potential for efficient coupling with supercritical carbon dioxide power cycles. Underground rock cannot be insulated, thus small heat storage systems with high surface to volume ratios are not feasible because of excessive heat losses. The minimum heat storage capacity to enable seasonal storage is {approx}0.1 Gigawatt-year. Three technologies can create the required permeable rock: (1) hydro-fracture, (2) cave-block mining, and (3) selective rock dissolution. The economic assessments indicated a potentially competitive system for production of intermediate load electricity. The basis for a nuclear geothermal system with LWRs exists today; but, there is need for added research and development before deployment. There are significantly greater challenges for geothermal heat storage at higher temperatures. Such systems are strongly dependent upon the local geology. (authors)

15 GEOTHERMAL ENERGY↗

The Effects of Chronic Sleep Restriction on Multiple Object Tracking

The ability to simultaneously track numerous moving objects in the presence of irrelevant stimuli is essential for carrying out a variety of tasks. Sleep loss has been found to impair neurocognitive functioning and, as a result, attentional processing capacity is reduced. A common form of sleep loss is chronic sleep restriction (CSR), in which an inadequate amount of sleep is obtained over consecutive days. The objective of the current study was to determine if performance on the multiple object tracking (MOT) task was adversely impacted by a week of CSR. Twelve healthy participants (6 males, 6 females) kept a fixed sleep-wake schedule, with a constant waketime, at home for four weeks (activity monitors worn on the participant’s nondominant wrist were used to confirm compliance). Weeks one and three were deemed washout weeks, during which participants maintained a 9-hour sleep-wake schedule. Weeks two and four were deemed experimental weeks, during which participants were randomly assigned a 5-hour (CSR) and 9-hour (sleep satiation) sleep-wake schedule. Following night seven of each experimental week, participants completed a 13-hour laboratory visit under dim light (less than 15 lux) where they maintained a constant posture and were provided with hourly isocaloric snacks. MOT was presented at approximately 6 and 8 hours after waking. Participants were required to track four, five, or six moving targets in the presence of identical distractors (always 12 total objects). It was found that participants slept significantly less during the week of CSR compared to the week of sleep satiation. There was no difference in the overall proportion of correct MOT responses following the CSR and sleep satiation weeks. However, an additional analysis examining only the 6 target condition found that the proportion of correct responses was significantly lower following the week of CSR. These findings suggest that CSR has an adverse impact on tracking performance when the cognitive demand was higher. This has implications for individuals, such as air traffic controllers and truck drivers, who must visually track multiple moving objects under high workload situations, often while chronically sleep deprived.

sleep restriction↗

Capacity Valuation of Demand Response in the Presence of Variable Generation through Monte Carlo Analysis

While smart demand-side management technologies have significant potential to support the integration of variable renewable generation sources in the electricity system, rigorously quantifying the contribution of demand response to meeting peak demand remains a challenge due to the nontrivial intertemporal considerations involved in demand response operations. This paper contributes to the field of capacity value by studying the effect of customer participation in DR programs, investigating the contribution that shiftable loads can provide for capacity value in a smart, standalone system. This paper uses a Monte Carlo simulation to investigate the effect of DR on the loss of load probability in a sequential simulation framework. Also presented here is a load-shifting model for customer loads where time of use is based on need, priority, and the availability of generation. Results of this work present a quantitative value for the equivalent firm capacity of demand response programs for a specific test case that depends on the participation rate among consumers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mixed Polyanion Glass Cathodes: Mixed Alkali Effect

In lithium-ion batteries, mixed polyanion glass cathodes have demonstrated high capacities (200-500 mAh/g) by undergoing conversion and intercalation reactions. Mixed polyanion glasses typically have the same fundamental issues as other conversion cathodes, i.e.: large hysteresis, capacity fade, and 1st-cycle irreversible loss. A key advantage of glass cathodes is the ability to tailor their composition to optimize the desired physical properties and electrochemical performance. The strong dependence of glass physical properties (e.g., ionic diffusivity, electrical conductivity, and chemical durability) on the composition of alkali mixtures in a glass is well known and has been named the mixed alkali effect. The mixed alkali effect on battery electrochemical properties is reported here for the first time. Depending on glass composition, the mixed alkali effect is shown to improve capacity retention during cycling (from 39% to 50% after 50 cycle test), to reduce the 1st-cycle irreversible loss (from 41% to 22%), and improve the high power (500 mA/g) capacity (from 50% to 67% of slow discharge capacity).

Kercher, A. K.↗

Battery500 Consortium: Development of High-Capacity Cathodes and Robust Solid Electrolytes

The goal off this EERE-BMR-Battery 500 consortium project was to provide the supporting science and to lead the Keystone 1 project. Key findings include: identification of 1st cycle loss of high nickel NMC materials as a major opportunity to increase the capacity of these cathode materials. The selective use of substituents and surface coatings was identified as a potential way of decreasing the 1st cycle loss and in increasing capacity retention. Niobium at around the 1% level was found to be optimum. In addition, operando DSC was utilized to scope out the stability range of electrolytes developed by the Battery 500 team.

25 ENERGY STORAGE↗

Sound at Scale: Characterizing Impacts of Noise Ordinances on the Onshore Wind Energy Technical Potential for the United States

Recent surveys have documented the rapid rise of sound ordinances across state and county jurisdictions, which has become crucial for wind energy siting. However, the lack of information on ordinances and computational challenges in turbine sound modeling create uncertainties regarding how evolving policies may affect resource potential and clean energy objectives. Therefore, we develop an approach to evaluate wind turbine sound profiles at millions of locations across the U.S. and translate them into setback distances for every residential structure. Compared to a baseline reference scenario, we find a 7% reduction in the national wind energy capacity potential when accounting for counties with existing sound ordinances. Additionally, when expanding the surveyed sound ordinances nationwide, we observe a potential loss of 53% of the national wind capacity under the most stringent ordinances, with a disproportionate share of this lost capacity coming from high-quality and low-cost wind resource. This work reveals that neglecting sound ordinances results in a significant overestimation of wind resource potential and highlights the important trade-offs between increased wind energy deployment to meet target decarbonization goals and the social/environmental impacts of this deployment that must be considered.

aeroacoustics↗

Multi-Gigawatt Electric Highway

Ultra-Compact Electrical Transmission Lines are a new transmission line technology that uses large, hollow, aluminum beams to carry current instead of thin wires. Capacity is 4.5 times higher, power losses are 3 times lower, and cost per mile is a little lower than conventional lines. Resilience and reliability are higher. The beams are enclosed within concrete walls and out of the weather, protected from high winds, ice storms, fires, and lightning. The 230 kV version is 9 feet high x 11 feet wide and can use existing rights of way next to existing transmission lines or highways. With a little landscaping, these transmission lines are not an eyesore and will be much easier to permit on existing rights of way.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Superoxide Dismutase Protects Osteoprogenitors from Irradiation with Low-LET but Not High-LET Species

Ionizing radiation-induced bone loss appears to be a two-stage process: first an early increase in pro-resorption cytokines and increased bone resorption by osteoclasts, followed by a decrease in bone formation by osteoblasts. This results in a net loss of mass in mineralized bone tissue. The molecular mechanisms underlying the imbalance in bone remodeling caused by exposure to radiation are not fully understood. We hypothesized that the radiation-induced rise in reactive oxygen species (ROS) damages osteoblast progenitors, leading to a decrease in number and activity of differentiated progeny. We have shown that a diet high in antioxidant capacity prevents radiation-induced bone loss in adult mice (Schreurs et al. 2016) by reducing the early increase in pro-resotption cytokines. Here, we investigated the damaging effects of radiation exposure on cells in the osteoblast lineage, testing if addition of the exogenous antioxidant enzyme, superoxide dismutase (SOD) can mitigate radiation damage. Osteoprogenitors were grown in vitro from the marrow of 16wk old, male C57Bl/6 mice. Cells were irradiated 3 days after plating (day 0) with either gamma (Cs-137, 0.1-5Gy) or iron (Fe-56, 600 MeV/n, 0.5-2Gy), and then grown until day 10. SOD or vehicle was added 2 hours before irradiation (SOD at 200U/ml), twice a day and up to day 5, for a total of 2 days treatment. Cell behavior was assessed by: (a) colony number (counted on day 7), (b) DNA content (surrogate for cell number) to assess cell growth (percent change between day 3 and day 10) and (c) alkaline phosphatase activity (osteoblast differentiation marker). Results show that SOD protected cells from the adverse effects of low-LET ionizing radiation, but not high-LET radiation. These novel results provide an interesting platform to explore further diverse effects and damages caused by low-LET and high-LET, pointing toward different mechanisms and possible intervention strategies for radiation-induced bone loss.

superoxide dismutase↗

Superoxide Dismutase Protects Osteoprogenitors from Irradiation with Low-LET but Not High-LET Species

Ionizing radiation-induced bone loss appears to be a two-stage process: first an early increase in pro-resorption cytokines and increased bone resorption by osteoclasts, followed by a decrease in bone formation by osteoblasts. This results in a net loss of mass in mineralized bone tissue. The molecular mechanisms underlying the imbalance in bone remodeling caused by exposure to radiation are not fully understood. We hypothesized that the radiation-induced rise in reactive oxygen species (ROS) damages osteoblast progenitors, leading to a decrease in number and activity of differentiated progeny. We have shown that a diet high in antioxidant capacity prevents radiation-induced bone loss in adult mice (Schreurs et al. 2016) by reducing the early increase in pro-resotption cytokines. Here, we investigated the damaging effects of radiation exposure on cells in the osteoblast lineage, testing if addition of the exogenous antioxidant enzyme, superoxide dismutase (SOD) can mitigate radiation damage. Osteoprogenitors were grown in vitro from the marrow of 16-week-old, male C57Bl6 mice. Cells were irradiated 3 days after plating (day 0) with either gamma (137Cs, 0.1-5Gy) or iron (56Fe, 600 MeVn, 0.5-2Gy), and then grown until day 10. SOD or vehicle was added 2 hours before irradiation (SOD at 200Uml), twice a day and up to day 5, for a total of 2 days treatment. Cell behavior was assessed by: (a) colony number (counted on day 7), (b) DNA content (surrogate for cell number) to assess cell growth (percent change between day 3 and day 10) and (c) alkaline phosphatase activity (osteoblast differentiation marker). Results show that SOD protected cells from the adverse effects of low-LET(Linear Energy Transfer) ionizing radiation, but not high-LET radiation. These novel results provide an interesting platform to explore further diverse effects and damages caused by low-LET and high-LET, pointing toward different mechanisms and possible intervention strategies for radiation-induced bone loss.

osteoblasts↗

A Strategy for Constructing Pore‐Space‐Partitioned MOFs with High Uptake Capacity for C 2 Hydrocarbons and CO 2

Abstract Introduction of pore partition agents into hexagonal channels of MIL‐88 type (acs topology) endows materials with high tunability in gas sorption. Here, we report a strategy to partition acs framework into pacs (partitioned acs) crystalline porous materials (CPM). This strategy is based on insertion of in situ synthesized 4,4′‐dipyridylsulfide (dps) ligands. One third of open metal sites in the acs net are retained in pacs MOFs; two thirds are used for pore‐space partition. The Co 2 V‐pacs MOFs exhibit near or at record high uptake capacities for C 2 H 2 , C 2 H 4 , C 2 H 6 , and CO 2 among MOFs. The storage capacity of C 2 H 2 is 234 cm 3 g −1 (298 K) and 330 cm 3 g −1 (273 K) at 1 atm for CPM‐733‐dps (the Co 2 V‐BDC form, BDC=1,4‐benzenedicarboxylate). These high uptake capacities are accomplished with low heat of adsorption, a feature desirable for low‐energy‐cost adsorbent regeneration. CPM‐733‐dps is stable and shows no loss of C 2 H 2 adsorption capacity following multiple adsorption–desorption cycles.

Wang, Yong↗

A Strategy for Constructing Pore-Space-Partitioned MOFs with High Uptake Capacity for C 2 Hydrocarbons and CO 2

Introduction of pore partition agents into hexagonal channels of MIL-88 type (acs topology) endows materials with high tunability in gas sorption. Here, we report a strategy to partition acs framework into pacs (partitioned acs) crystalline porous materials (CPM). This strategy is based on insertion of in situ synthesized 4, 4'-dipyridylsulfide (dps) ligands. As a result, one third of open metal sites in the parent acs net are retained in pacs MOFs, while two thirds are used for pore space partition. The newly synthesized Co 2 V-pacs MOFs, with optimized pore space and open metal sites, exhibit near or at record high uptake capacities for C 2 H 2 , C 2 H 4 , C 2 H 6 , and CO 2 among MOFs. For example, the storage capacity of C 2 H 2 is 234 cm 3 /g -1 (298 K) and 330 cm 3 /g -1 (273K) at 1 atm for CPM-733-dps (the Co 2 V-BDC form, BDC=1,4-benzenedicarboxylate), higher than benchmark MOFs such as MOF-74 and all other pacs members. These high uptake capacities are accomplished with low heat of adsorption, a feature desirable for low-energy-cost adsorbent regeneration. CPM-733-dps is stable and shows no loss of C 2 H 2 adsorption capacity following multiple adsorption–desorption cycles.

25 ENERGY STORAGE↗

Simulation of the Effect of Contact Area Loss in All-Solid-State Li-Ion Batteries

Maintaining the physical contact between the solid electrolyte and the electrode is important to improve the performance of all-solid-state batteries. Imperfect contact can be formed during cell fabrication and will be worsened due to cycling, resulting in degradation of the battery performance. In this paper, the effect of imperfect contact area was incorporated into a 1-D Newman battery model by assuming the current and Li concentration will be localized at the contacted area. Constant current discharging processes at different rates and contact areas were simulated for a film-type Li|LiPON|LiCoO 2 all-solid-state Li-ion battery. The capacity drop was correlated with the contact area loss. It was found at lower cutoff voltage, the correlation is almost linear with a slope of 1; while at a higher cutoff voltage, the dropping rate is slower. To establish the relationship between the applied pressure and the contact area, Persson's contact mechanics theory was applied, as it uses self-affined surfaces to simplify the multi-length scale contacts in all-solid-state batteries. The contact area and pressure were computed for both film-type and bulk-type all-solid-state Li-ion batteries. The model is then used to suggest how much pressures should be applied to recover the capacity drop due to contact area loss.

25 ENERGY STORAGE↗

Evaluating temperature dependent degradation mechanisms of silicon-graphite electrodes and the effect of fluoroethylene carbonate electrolyte additive

Understanding and overcoming the relatively high rate of degradation observed with silicon (Si)-based anodes in lithium (Li)-ion batteries (LiBs) is crucial for developing cells with increased energy density. The capacity fade of Si-graphite (Gr) electrodes in electrolytes with and without 10 wt% fluoroethylene carbonate (FEC) is explored during cycling at temperatures of 25, 45, and 70 °C, focusing on the complex degradation modes arising from loss of active material, loss of Li inventory, and cell resistance growth. We first show the common half-cell testing cannot be used at elevated temperatures as the performance of Li metal overshadows the behavior of Si-Gr electrode. Symmetric cell configuration successfully eliminates the effect of foreign materials, and reveals that while the presence of FEC provides better passivation of Si, it also results in greater parasitic reactions at 70 °C and faster capacity fade. The electrolyte without FEC, on the other hand, shows higher capacity retention at 70 °C. Finally, we propose a multi-step test protocol which can successfully deconvolute the information on loss of Li inventory and of active material. By combining half-cell and symmetric cell test methods, we demonstrate that loss of active material is reduced at higher temperatures and the dominant mechanisms of capacity loss for Si-Gr electrodes at elevated temperatures is loss of Li inventory.

25 ENERGY STORAGE↗