Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Supervisory genset control in range-extended electric vehicle

A controls system for a range-extended electric vehicle comprising an overall system control unit, an engine control module configured to control a range extender of the range-extended electric vehicle, power electronics configured to control a generator of the range-extended electric vehicle, and a supervisory control module coupled between the overall system control unit and the engine control module and the power electronics, the supervisory control module configured to receive information from the overall system control unit and provide commands to the engine control module and the power electronics.

Li, Ke↗

Resin transfer molding systems and control logic for manufacturing fiber-reinforced composite parts

Presented are manufacturing control systems for fabricating composite-material structures, methods for making/operating such systems, and resin transfer molding techniques for ameliorating race-tracking effects in fiber-reinforced polymer panels. A method for forming a composite-material construction includes confirming, via a system electronic control unit (ECU), that a fiber-based preform is placed in a mold cavity and that opposing mold segments of the molding apparatus are sealed together. A filler, such as a compressible bladder, a cluster of spring-biased pins, or a spray-chopped fiber bed, is introduced into a void between the fiber-based preform and a tool face of one mold segment to thereby eliminate an unwanted resin race track. The system ECU commands a resin pump to inject resin through a primary gate of the molding apparatus and into the mold cavity to thereby impregnate the fiber-based preform with the resin. One or more vents operate to evacuate air from the mold.

Rodgers, William R.↗

Sensitivity-Driven Experimental Design to Facilitate Control of Dynamical Systems

Control of nonlinear dynamical systems is a complex and multifaceted process. Essential elements of many engineering systems include high-fidelity physics-based modeling, offline trajectory planning, feedback control design, and data acquisition strategies to reduce uncertainties. Here this article proposes an optimization-centric perspective which couples these elements in a cohesive framework. We introduce a novel use of hyper-differential sensitivity analysis to understand the sensitivity of feedback controllers to parametric uncertainty in physics-based models used for trajectory planning. These sensitivities provide a foundation to define an optimal experimental design which seeks to acquire data most relevant in reducing demand on the feedback controller. Our proposed framework is illustrated on the Zermelo navigation problem and a hypersonic trajectory control problem using data from NASA’s X-43 hypersonic flight tests.

42 ENGINEERING↗

Apparatus and system for controlling power to an air conditioning compressor for a vehicle

A climate control system for vehicles includes an internal combustion engine that may be coupled to selectively power a first motor generator, and an air conditioning compressor that may be selectively powered by one or both of the first motor generator and a second motor generator, or by the internal combustion engine. The system may include a rechargeable battery, and a vehicle controller having a vehicle state circuit structured to determine a vehicle operating condition value and a state-of-charge value of the rechargeable battery, and a coupling determination circuit structured to provide an internal combustion engine-first motor generator coupling command in response to the vehicle operating condition value and the state-of-charge value. In response to the internal combustion engine-first motor generator coupling command being provided as coupled, the internal combustion engine may power the first motor generator.

Kumar, Mahesh Madurai↗

Systems and methods for the detection of low-level harmful substances in a large volume of fluid

A method and device for the detection of low-level harmful substances in a large volume of fluid comprising using a concentrator system to produce a retentate and analyzing the retentate for the presence of at least one harmful substance. The concentrator system performs a method comprising pumping at least 10 liters of fluid from a sample source through a filter. While pumping, the concentrator system diverts retentate from the filter into a container. The concentrator system also recirculates at least part of the retentate in the container again through the filter. The concentrator system controls the speed of the pump with a control system thereby maintaining a fluid pressure less than 25 psi during the pumping of the fluid; monitors the quantity of retentate within the container with a control system, and maintains a reduced volume level of retentate and a target volume of retentate.

47 OTHER INSTRUMENTATION↗

SiC Based Modular Transformer-less MW-Scale Power Conditioning System and Control for Flexible CHP System

This project aims at developing a SiC-based, modular, transformer-less (60-Hz-transformers-free), MW-scale, four-wire DC/AC power conditioning system (PCS) converter, and a corresponding control system for flexible-CHP (F-CHP) systems. With the help of an F-CHP controller and power electronics converters, different CHP sources, renewable sources, and batteries can be assembled to the DC grid, which is then connected to the medium voltage (MV) AC grid through the PCS converter. To meet grid support and performance requirements, the F-CHP controller design and PCS converter design follow IEEE 1547 and IEEE 2030.7 standards. Five main tasks, including PCS converter design, F-CHP controller development, PCS converter prototype building and testing, F-CHP controller testing, and PCS paralleling, have been carried out. In this project, the F-CHP controller testing has been completed in simulation, HIL and HTB, and the PCS converter prototypes have been successfully built and tested.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Neural Lyapunov Control for Power System Transient Stability: A Deep Learning-Based Approach

We report that power system control and transient stability analysis play essential roles in secure system operation. Control of power systems typically involves highly nonlinear and complex dynamics. Most of the existing works address such problems with additional assumptions in system dynamics, leading to a requirement for a complete and general solution. This paper, therefore, proposes a novel control framework for various power system control and stability problems leveraging a learning-based approach. The proposed framework includes a two-module structure that iteratively and jointly learns the candidate Lyapunov function and control law via deep neural networks in a learning module. Meanwhile, it guides the learning procedure towards valid results satisfying Lyapunov conditions in a falsification module. The introduced termination criteria ensure provable system stability. This control framework is verified through several studies handling different types of power system control problems. The results show that the proposed framework is generalizable and can simplify the control design for complex power systems with the stability guarantee and enlarged region of attraction.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of a neural network technique for KSTAR Thomson scattering diagnostics

Neural networks provide powerful approaches of dealing with nonlinear data and have been successfully applied to fusion plasma diagnostics and control systems. Controlling tokamak plasmas in real time is essential to measure the plasma parameters in situ. However, the χ{sup 2} method traditionally used in Thomson scattering diagnostics hampers real-time measurement due to the complexity of the calculations involved. In this study, we applied a neural network approach to Thomson scattering diagnostics in order to calculate the electron temperature, comparing the results to those obtained with the χ{sup 2} method. The best results were obtained for 10{sup 3} training cycles and eight nodes in the hidden layer. Our neural network approach shows good agreement with the χ{sup 2} method and performs the calculation twenty times faster.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of Globus-M Tokamak Poloidal System and Plasma Position Control

In order to provide efficient performance of tokamaks with vertically elongated plasma position, control systems for limited and diverted plasma configuration are required. The accuracy, stability, speed of response, and reliability of plasma position control as well as plasma shape and current control depend on the performance of the control system. Therefore, the problem of the development of such systems is an important and actual task in modern tokamaks. In this study, the measured signals from the magnetic loops and Rogowski coils are used to reconstruct the plasma equilibrium, for which linear models in small deviations are constructed. We apply methods of the H∞-optimization theory to the synthesize control system for vertical and horizontal position of plasma capable to working with structural uncertainty of the models of the plant. These systems are applied to the plasma-physical DINA code which is configured for the tokamak Globus-M plasma. The testing of the developed systems applied to the DINA code with Heaviside step functions have revealed the complex dynamics of plasma magnetic configurations. Being close to the bifurcation point in the parameter space of unstable plasma has made it possible to detect an abrupt change in the X-point position from the top to the bottom and vice versa. Development of the methods for reconstruction of plasma magnetic configurations and experience in designing plasma control systems with feedback for tokamaks provided an opportunity to synthesize new digital controllers for plasma vertical and horizontal position stabilization. It also allowed us to test the synthesized digital controllers in the closed loop of the control system with the DINA code as a nonlinear model of plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laboratory testing methods to evaluate the reliability of occupancy sensors for commercial building applications

The energy performance of commercial buildings is greatly influenced by occupants which are highly variable and among the most unpredictable components of a building's operation. While most building control systems use fixed, predetermined occupancy schedules, these fixed occupancy levels can be quite different from actual occupancy. This can cause unnecessary energy consumption, particularly from heating, ventilation, and air conditioning (HVAC) and lighting systems which are responsible for approximately 60% of commercial buildings' energy use. The use of occupancy counting sensor systems integrated with building management system controls is one method that can be used to improve the energy-consuming performance of buildings. However, there is no standardized universal methodology and metrics to evaluate their reliability. The aim of this research is to develop a uniform evaluation methodology to assess the reliability of occupancy counting sensor systems in a controlled laboratory environment. The developed testing methodology includes both “typical” scenarios representing the occupancy scenarios of a typical commercial building, and “failure” testing scenarios which represent a range of potential scenarios that may impact a sensor system's reliability. These methods were then implemented in a case study to evaluate the performance of two novel occupancy counting sensor systems (i.e., door-centric, and camera-based). Results suggest that typical testing results can be used to compare the overall performance of the occupancy counting sensor systems; however, failure testing is also important to understand the weaknesses of the sensor system in order to select the suitable one for the intended use of the commercial building. In addition, the proposed methodology includes a modified confusion matrix which enables the ability to identify if failures are caused by over or under counting occupants and to what extent this occurs over the testing period.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Intrinsic use control for system and use controlled component security

An Initialization Unit (IU) initiates an initial secure connection with an Intrinsic Use Control (IUC) Chip based on very large random numbers (VLRNs). The IUC Chip in turn initiates a secondary secure connection between it and one or more Use Controlled Components (UCCs). Polling by the IU allows confirmation of an ongoing secure connection, and also allows the IUC Chip to confirm the secondary secure connection to the UCCs. Removal or improper polling response from one of the UCCs results in a response from the IUC Chip that may include notification of tampering, or temporary or permanent discontinued operation of the offending UCC. Permanent discontinued operation may include destruction of the offending UCC, and cascaded discontinued operation of all other UCCs secured by the IUC Chip. A UCC may in turn be another nested layer of IUC Chips, controlling a corresponding layer of UCCs, ad infinitum.

97 MATHEMATICS AND COMPUTING↗

Intrinsic use control for system and use controlled component security

An Initialization Unit (IU) initiates an initial secure connection with an Intrinsic Use Control (IUC) Chip based on very large random numbers (VLRNs). The IUC Chip in turn initiates a secondary secure connection between it and one or more Use Controlled Components (UCCs). Polling by the IU allows confirmation of an ongoing secure connection, and also allows the IUC Chip to confirm the secondary secure connection to the UCCs. Removal or improper polling response from one of the UCCs results in a response from the IUC Chip that may include notification of tampering, or temporary or permanent discontinued operation of the offending UCC. Permanent discontinued operation may include destruction of the offending UCC, and cascaded discontinued operation of all other UCCs secured by the IUC Chip. A UCC may in turn be another nested layer of IUC Chips, controlling a corresponding layer of UCCs, ad infinitum.

97 MATHEMATICS AND COMPUTING↗