Search NASA⌕ Search

SEARCH · Search NASA

Results for “DIODE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Direct diode pumped Ti:sapphire lasers and amplifiers

Direct diode-pumped Ti:sapphire laser amplifiers use fiber-coupled laser diodes as pump beam sources. The pump beam may be polarized or non-polarized. Light at wavelengths below 527 nm may be used in cryogenic configurations. Multiple diode outputs may be polarization or spectrally combined.

Kirchner, Matthew S.↗

Tunable diode laser absorption spectroscopy with corrected laser ramping nonlinearities

A tunable diode laser absorption spectroscopy device includes a tunable diode laser. A laser driver is configured to drive the diode laser and ramp it within a particular frequency range. An analyte gas container, a reference gas container, and a fringe generating device are configured to receive the laser therethrough. An optical detector is configured to detect the laser after it has passed through the analyte gas container and/or the reference gas container, and the in-line fringe generating device. An acquisition card is configured to sample an output of the optical detector. A spectral analyzer is configured to receive output data from the acquisition card, determine a spectrum of the output data, decouple the fringe spectrum from the measured spectrum, calibrate the spectrum based on an expected ideal spectrum of both the fringe and reference gas, and determine a composition of the analyte based on the calibrated spectrum.

42 ENGINEERING↗

Current generation from radiation with diamond diode-based devices for detection or power generation

Diamond diode-based devices are configured to convert radiation energy into electrical current, useable for sensing (i.e., detection) or delivery to a load (i.e., energy harvesting). A diode-based detector includes an intrinsic diamond layer arranged between p-type diamond and n-type diamond layers, with the detector further including at least one of (i) a boron containing layer arranged proximate to the n-type and/or the intrinsic diamond layers, or (ii) an intrinsic diamond layer thickness in a range of 10 nm to 300 microns. A diode-based detector may be operated in a non-forward biased state, with a circuit used to transmit a current pulse in a forward bias direction to reset a detection state of the detector. An energy harvesting device may include at least one p-i-n stack (including an intrinsic diamond layer between p-type diamond and n-type diamond layers), with a radioisotope source arranged proximate to the at least one p-i-n stack.

Holmes, Jason M.↗

Evaluation of a 3D Diode Array Dosimeter for Helical Tomotherapy Delivery QA

The Delta4 biplanar diode array dosimeter was validated for helical tomotherapy delivery QA. The basic detector characteristics were found to be satisfactory in terms of short-term reproducibility (0.1%), linearity (<0.1%), dose rate dependence (0.4%), and absolute calibration accuracy (0.4% in the center of the phantom compared with the independently calibrated diode). Relative calibration of the arrays was verified by comparison with film and by rotating the detector 180{sup o}. The dosimeter response to rotational irradiation changed by no more than 0.2% when one of the detector boards was replaced by the homogeneous phantom material. The daily output correction factor can be derived from a Delta4 measurement in a uniform cylindrical field. The {gamma}(3%, 3 mm) passing rate (absolute dose) was above 90% for all 9 evaluated clinical plans, and above 96% for all but one. The mean passing rate was 97 {+-} 2.7%. The plans varied in modulation factor, pitch, and calculation grid size. For best results, the phantom needs to be aligned carefully, preferably by megavoltage computed tomography imaging.

07 ISOTOPE AND RADIATION SOURCES↗

Midline Dose Verification with Diode In Vivo Dosimetry for External Photon Therapy of Head and Neck and Pelvis Cancers During Initial Large-Field Treatments

During radiotherapy treatments, quality assurance/control is essential, particularly dose delivery to patients. This study was designed to verify midline doses with diode in vivo dosimetry. Dosimetry was studied for 6-MV bilateral fields in head and neck cancer treatments and 10-MV bilateral and anteroposterior/posteroanterior (AP/PA) fields in pelvic cancer treatments. Calibrations with corrections of diodes were performed using plastic water phantoms; 190 and 100 portals were studied for head and neck and pelvis treatments, respectively. Calculations of midline doses were made using the midline transmission, arithmetic mean, and geometric mean algorithms. These midline doses were compared with the treatment planning system target doses for lateral or AP (PA) portals and paired opposed portals. For head and neck treatments, all 3 algorithms were satisfactory, although the geometric mean algorithm was less accurate and more uncertain. For pelvis treatments, the arithmetic mean algorithm seemed unacceptable, whereas the other algorithms were satisfactory. The random error was reduced by using averaged midline doses of paired opposed portals because the asymmetric effect was averaged out. Considering the simplicity of in vivo dosimetry, the arithmetic mean and geometric mean algorithm should be adopted for head/neck and pelvis treatments, respectively.

61 RADIATION PROTECTION AND DOSIMETRY↗

Spectroscopic performance of Low-Gain Avalanche Diodes for different types of radiation

LGADs (Low-Gain Avalanche Diodes or Detectors) are a type of silicon Avalanche Photo-Diodes originally developed for the fast detection of minimum ionizing particles in high-energy physics experiments. Thanks to their fast timing performance, the LGAD paradigm enables detectors to accurately measure minimum ionizing particles with a timing resolution of a few tens of picoseconds. Such a performance is due to a thin substrate and the presence of a moderate signal gain. This internal gain of a few tens is enough to compensate for the reduced charge deposition in the thinner substrate and the noise of fast read-out systems. While LGADs are optimized for the detection of minimum ionizing particles for high-energy particle detectors, it is critical to study their performance for the detection of different types of particle, such as X-rays, gamma-rays, or alphas. In this paper, we evaluate the gain of three types of LGADs: two devices with different geometries and doping profiles fabricated by Brookhaven National Laboratory, and one fabricated by Hamamatsu Photonics with a different process. Since the gain in LGADs depends on the bias voltage applied to the sensor, pulse-height spectra have been acquired for bias voltages spanning from the depletion voltage up to the breakdown voltage. Finally, the signal-to-noise ratio of the generated signals and the shape of their spectra allow us to probe the underlying physics of the multiplication process.

47 OTHER INSTRUMENTATION↗

Self-Field-Induced Josephson Diode Effect

Josephson diodes are of interest for nonlinear superconducting circuit elements, which have many applications such as in solid-state qubit readout and coupling. Many different mechanisms can give rise to Josephson diode effects (JDEs). In this work, we investigate JDEs generated by the self-field of the supercurrent in the junction. To this end, we experimentally investigate JDEs in the supercurrent quantum interference patterns of planar hybrid Josephson junctions, composed of a cadmium arsenide thin film interfaced with a conventional superconductor. A model that includes the supercurrent self-field accurately describes the experimental observations. We show that self-field-induced JDEs are generally expected in planar junctions in perpendicular magnetic fields, even in cases of symmetric and uniform junctions, as long as they exhibit sufficiently large critical currents. Here, we discuss the tunability of self-field-induced JDEs via the supercurrent density and other parameters.

Josephson diode↗

Low-leakage p-type diamond Schottky diodes prepared using vacuum ultraviolet light/ozone treatment

Room-temperature fabrication of Schottky diodes was demonstrated for p-type boron-doped diamond. This fabrication method's key technique is selective modification of surface termination from monohydride into oxygen groups using vacuum ultraviolet light irradiation in oxygen. The Au contacts, formed on the hydrogen-terminated surface, maintained Ohmic properties after this selective surface oxidation. The Au contacts then deposited on the oxidized surface, imparting Schottky properties. The lateral-type diodes comprising Au Schottky contacts and Au Ohmic contacts showed blocking voltage higher than 1 kV without electrode guarding. The leakage current at 1 kV was as low as 30 pA.

36 MATERIALS SCIENCE↗

Alpha particle detection with GaN Schottky diodes

Ni/GaN Schottky diode radiation detectors were fabricated on 3-mum-thick unintentionally doped n-GaN films grown by molecular beam epitaxy (MBE) and metal organic chemical vapor deposition (MOCVD) and on 12-mum-thick undoped n-GaN layers prepared by epitaxial lateral overgrowth (ELOG). The reverse current of all detector structures was <10{sup -9} A for bias voltages necessary for detector operation, with the level of background donor doping of <10{sup 15} cm{sup -3}. With this doping level the space charge region of the Schottky diode could be extended to the entire thickness of the films. The charge collection efficiency of the detectors was close to 100% for MOCVD and ELOG detectors for alpha-particles with range comparable to the thickness of the layer. Electrical properties and deep trap spectra were also studied. The collection efficiency decreased when the concentra-tion of deep electron traps, particularly E{sub c}-0.6 eV traps, increased in MBE grown films.

36 MATERIALS SCIENCE↗

Operational Characteristics of SiC Diodes as Ionizing Radiation Detectors

In order to explore the possibility of using SiC detectors in nuclear physics applications in extreme environments, the operational characteristics of 4H-SiC Schottky diodes with different dopant concentrations have been studied with {sup 12}C and {sup 16}O ions at various incident energies. The detector response has been investigated in term of linearity, energy resolution, signal rise-time and Charge Collection Efficiency as a function of the applied reverse bias and of the dopant concentration. Moreover, since one of the most promising properties of SiC detectors is their radiation hardness, the radiation damage, produced by irradiating SiC diodes with {sup 16}O ions at 35.2 MeV, has been evaluated by measuring the degradation of both the signal pulse-height and the energy resolution as a function of the {sup 16}O fluence.

36 MATERIALS SCIENCE↗

High-current diode with ferroelectric plasma source-assisted hollow anode

The operation of a ferroelectric plasma source-assisted hollow anode (HA) electron source in a vacuum diode powered by an {approx}200 kV and {approx}400 ns pulsed generator was studied using time- and space-resolved laser induced fluorescence diagnostics. It was found that the plasma ion ''temperature'' in the vicinity of the HA output grid increases up to {approx}15 eV during the accelerating pulse, which is consistent with a model of the potential screening of the grid by the randomly moving ions [Phys. Plasmas 13, 073506 (2006)]. Also it was shown that the increase in the HA plasma potential up to several kilovolts because of the appearance of a noncompensated ion charge in the HA bulk plasma due to electrons fast extraction, leads to explosive emission centers being generated at the HA grid and to nonuniformity in the cross-sectional electron beam current density. Finally, the plasma prefilled mode of diode operation was studied using a simple one-dimensional model of the plasma erosion and the HA plasma electron heating by energetic ions was considered.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray detectors based on GaN Schottky diodes

GaN Schottky diodes have been fabricated and tested as x-ray detectors in the range from 6 to 21 keV. The spectral response has been measured and is compared to its theoretical value. The study of the response and its temporal dynamics as a function of the bias allows to identify a photovoltaic behavior at low bias and a photoconductive one at larger reverse biases. The GaN diode turned out to be linear as a function of the incident power. The noise and detectivity are given and discussed.

36 MATERIALS SCIENCE↗

Polarization-engineered GaN/InGaN/GaN tunnel diodes

We report on the design and demonstration of polarization-engineered GaN/InGaN/GaN tunnel junction diodes with high current density and low tunneling turn-on voltage. Wentzel-Kramers-Brillouin calculations were used to model and design tunnel junctions with narrow band gap InGaN-based barrier layers. N-polar p-GaN/In{sub 0.33}Ga{sub 0.67}N/n-GaN heterostructure tunnel diodes were grown using molecular beam epitaxy. Efficient interband tunneling was achieved close to zero bias with a high current density of 118 A/cm{sup 2} at a reverse bias of 1 V, reaching a maximum current density up to 9.2 kA/cm{sup 2}. These results represent the highest current density reported in III-nitride tunnel junctions and demonstrate the potential of III-nitride tunnel devices for a broad range of optoelectronic and electronic applications.

36 MATERIALS SCIENCE↗

Temperature dependent electrical transport behavior of InN/GaN heterostructure based Schottky diodes

InN/GaN heterostructure based Schottky diodes were fabricated by plasma-assisted molecular beam epitaxy. The temperature dependent electrical transport properties were carried out for InN/GaN heterostructure. The barrier height and the ideality factor of the Schottky diodes were found to be temperature dependent. The temperature dependence of the barrier height indicates that the Schottky barrier height is inhomogeneous in nature at the heterostructure interface. The higher value of the ideality factor and its temperature dependence suggest that the current transport is primarily dominated by thermionic field emission (TFE) other than thermionic emission (TE). The room temperature barrier height obtained by using TE and TFE models were 1.08 and 1.43 eV, respectively.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

On the ideality factor of the radiative recombination current in semiconductor light-emitting diodes

While there have been many discussions on the standard Si pn-diodes, little attention has been paid and confusion still arises on the ideality factor of the radiative recombination current in semiconductor light-emitting diodes (LEDs). In this letter, we theoretically demonstrate and experimentally confirm by using blue and infrared semiconductor LEDs that the ideality factor of the radiative recombination current is unity especially for low-current-density ranges. We utilize the data of internal quantum efficiency measured by the temperature-dependent electroluminescence to separate the radiative current component from the total current.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of a synthetic single crystal diamond Schottky diode for radiotherapy electron beam dosimetry

Purpose: To investigate the dosimetric properties of synthetic single crystal diamond based Schottky diodes under irradiation with therapeutic electron beams from linear accelerators. Methods: A single crystal diamond detector was fabricated and tested under 6, 8, 10, 12, and 15 MeV electron beams. The detector performances were evaluated using three types of commercial detectors as reference dosimeters: an Advanced Markus plane parallel ionization chamber, a Semiflex cylindrical ionization chamber, and a p-type silicon detector. Preirradiation, linearity with dose, dose rate dependence, output factors, lateral field profiles, and percentage depth dose profiles were investigated and discussed. Results: During preirradiation the diamond detector signal shows a weak decrease within 0.7% with respect to the plateau value and a final signal stability of 0.1% (1{sigma}) is observed after about 5 Gy. A good linear behavior of the detector response as a function of the delivered dose is observed with deviations below {+-}0.3% in the dose range from 0.02 to 10 Gy. In addition, the detector response is dose rate independent, with deviations below 0.3% in the investigated dose rate range from 0.17 to 5.45 Gy/min. Percentage depth dose curves obtained from the diamond detector are in good agreement with the ones from the reference dosimeters. Lateral beam profile measurements show an overall good agreement among detectors, taking into account their respective geometrical features. The spatial resolution of solid state detectors is confirmed to be better than that of ionization chambers, being the one from the diamond detector comparable to that of the silicon diode. A good agreement within experimental uncertainties was also found in terms of output factor measurements between the diamond detector and reference dosimeters. Conclusions: The observed dosimetric properties indicate that the tested diamond detector is a suitable candidate for clinical electron beam dosimetry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Influence of radiation defects on electrical losses in silicon diodes irradiated with electrons

Silicon diodes with a p{sup +}-n junction irradiated with 3.5-MeV electrons (the fluence ranged from 10{sup 15} to 4 x 10{sup 16} cm{sup -2}) have been studied. It is established that the dependence of the tangent of the angle of electrical losses tan{delta} on the frequency f of alternating current in the range f = 10{sup 2}-10{sup 6} Hz is a nonmonotonic function with two extrema: a minimum and a maximum. Transformation of the dependences tan{delta}(f) as the electron fluence and annealing temperature are increased is caused by a variation in the resistance of n-Si (the base region of the diodes) as a result of accumulation (as the fluence is increased) or disappearance and reconfiguration (in the course of annealing) of radiation defects. The role of time lag of the defect recharging in the formation of tan{delta}(f) is insignificant.

36 MATERIALS SCIENCE↗

Effect of spacer layers on current-voltage characteristics of resonant-tunneling diode

Using the numerical solution to the Schroedinger equation, current-voltage characteristics of the resonant-tunneling diode with spacer layers were obtained. The dependences of the peak current of the resonant-tunneling diode on the emitter spacer width were plotted. It was shown that the peak current depends periodically on the emitter spacer width. The constructed electron density diagrams showed that the increase in the peak current is associated with the resonant level in the emitter spacer region.

36 MATERIALS SCIENCE↗