SU-F-T-310: Does a Head-Mounted Ionization Chamber Detect IMRT Errors?

Purpose: The conventional plan verification strategy is delivering a plan to a QA-phantom before the first treatment. Monitoring each fraction of the patient treatment in real-time would improve patient safety. We evaluated how well a new detector, the IQM (iRT Systems, Germany), is capable of detecting errors we induced into IMRT plans of three different treatment regions. Results were compared to an established phantom. Methods: Clinical plans of a brain, prostate and head-and-neck patient were modified in the Pinnacle planning system, such that they resulted in either several percent lower prescribed doses to the target volume or several percent higher doses to relevant organs at risk. Unaltered plans were measured on three days, modified plans once, each with the IQM at an Elekta Synergy with an Agility MLC. All plans were also measured with the ArcCHECK with the cavity plug and a PTW semiflex 31010 ionization chamber inserted. Measurements were evaluated with SNC patient software. Results: Repeated IQM measurements of the original plans were reproducible, such that a 1% deviation from the mean as warning and 3% as action level as suggested by the manufacturer seemed reasonable. The IQM detected most of the simulated errors including wrong energy, a faulty leaf, wrong trial exported and a 2 mm shift of one leaf bank. Detection limits were reached for two plans - a 2 mm field position error and a leaf bank offset combined with an MU change. ArcCHECK evaluation according to our current standards also left undetected errors. Ionization chamber evaluation alone would leave most errors undetected. Conclusion: The IQM detected most errors and performed as well as currently established phantoms with the advantage that it can be used throughout the whole treatment. Drawback is that it does not indicate the source of the error.

60 APPLIED LIFE SCIENCES↗

A Fast, Accurate and Sensitive GC-FID Method for the Analyses of Glycols in Water and Urine

Glycols, specifically ethylene glycol and 1,2-propanediol, are some of the major organic compounds found in the humidity condensate samples collected on the International Space Station. The current analytical method for glycols is a GC/MS method with direct sample injection. This method is simple and fast, but it is not very sensitive. Reporting limits for ethylene glycol and 1,2-propanediol are only 1 ppm. A much more sensitive GC/FID method was developed, in which glycols were derivatized with benzoyl chloride for 10 minutes before being extracted with hexane. Using 1,3-propanediol as an internal standard, the detection limits for the GC/FID method was determined to be 50 ppb and the analysis only takes 7 minutes. Data from the GC/MS and the new GC/FID methods shows excellent agreement with each other. Factors affecting the sensitivity, including sample volume, NaOH concentration and volume, volume of benzoyl chloride, reaction time and temperature, were investigated. Interferences during derivatization and possible method to reduce interferences were also investigated.

Kuo, C. Mike↗

Final Report – Cooperative Research and Development Agreement between National Energy Technology Laboratory and Oxergy, Inc.

The NETL Raman Gas Analyzer (RGA) has been demonstrated to have an extremely fast response (<1 second) multi-gas analysis capability. All but the noble gases are Raman active, although the Raman interaction is weak. The RGA uses a reflectively lined capillary as the optical cell, providing both a small sample volume for fast gas exchange, and a much greater Raman signal collection than traditional instrument configurations. This allows very fast measurement of fuel gases (hydrogen, methane, ethane, propane) as well as other common industrial gases (carbon monoxide, carbon dioxide, nitrogen, oxygen, and water). This provides a new enabling technology for faster, smarter process control based on the chemical composition of the gases in the process – including improved fuel flexibility and efficiency for power generation systems. Research and development up to 2016 resulted in the construction of two field prototypes of the NETL RGA, which has been in applied to various laboratory applications for testing. The results of the testing have been used to improve the RGA design, with the intent to support technology transfer. The quality of the optical capillary used in the RGA is critical to its performance, and prior work at NETL produced a few optical capillaries superior to those commercially available. The production of high optical quality capillaries, however, was inconsistent in its results. With the support of the DOE Office of Technology Transitions, through the Technology Commercialization Fund program, this project was undertaken to address this commercialization barrier and to also evaluate the possible application of Raman gas analysis to a supercritical water gasification process being developed by Oxergy Inc. Oxergy, a small business located in Fairbanks, Alaska, is developing ultra-compact thermochemical reaction devices built with advanced manufacturing processes. Chief Technology Officer Jonathan Kamler holds the (pending) patent to Oxergy’s core reactor technology. Oxergy maintains wet-lab and combustion-lab space at the University of Alaska Fairbanks Center for Sustainable Living in Palmer, Alaska, where Mr. Kamler operates a pilot-scale, supercritical water gasification system designed and built by Oxergy. Mr. Kamler also operates an All Powers Labs Power Pallet gasifier coupled to a 10KW electrical generator as a dry biomass test platform at the Palmer facility. Both systems are suitable for real-world, collaborative testing of Raman gas analysis applications. The objectives of the CRADA include making the production of high-quality optical capillaries consistent and high yield, investigating other options for optical waveguides, and testing the capillaries for measurements in supercritical water gasification. Success on these objectives will support commercialization of both the RGA and supercritical water gasification technologies. Through the work performed on this project, a new apparatus was constructed and optimized to provide consistent production of high-quality optical capillaries. Several thick-walled capillaries were coated using this apparatus and shipped to Oxergy in September 2018 for testing in both dry gasification and supercritical water gasification process monitoring applications at University of Alaska Fairbanks facilities in Palmer. The strong earthquake near Anchorage and Palmer in November 2018 caused extensive damage and closure of the facilities used by Oxergy, preventing Oxergy from proceeding with experimental testing before the end of the project; the facility has been closed indefinitely. Earthquake damage prohibited the completion of all the project objectives prior to the end of the project. However, significant progress was made toward addressing a core technology commercialization barrier. The largest and most mature potential market for Raman gas analysis is its use in analytical instruments, which require sensitivity and low detection limits, and Oxergy’s market research found that market inertia is a barrier to commercial success in this market. Although NETL’s innovations in capillary coating have substantially improved Raman gas analysis capability, the likely market is expected to be niche applications that value the fast detection of real-time changes in gas composition.

Chorpening, Benjamin↗

Reflectance spectra of 'featureless' materials and the surface mineralogies of M- and E-class asteroids

In a search for diagnostic spectral parameters which can be used to distinguish different materials on the surface of asteroids and to provide information on the detection limits for mafic silicates, the 0.3- to 2.6-micron reflectance spectra of meteoritic enstatite (nearly pure MgSiO3), iron meteorite metal, magnetite, and amorphous carbon as well as various mixtures of these materials with mafic silicates were examined. Results are presented on the dependence of the spectral detectability of mafic silicates associated with metal, carbon, and magnetite on the particle sizes of the phases, their chemistries, crystal structures, and abundances. It is shown that the observational data for a representative M-class asteroid, (16) Psyche, are largely consistent with a fine-grained metal-rich surface assemblage, whereas data for the E-class asteroid (44) Nysa indicate that its surface is composed of fine-grained material similar to enstatite achondrites, with a small amount of material comparable to the chondritic inclusions found in the Cumberland Falls aubrite.

Cloutis, Edward A.↗

PCR-Induced Transitions Are the Major Source of Error in Cleaned Ultra-Deep Pyrosequencing Data

Ultra-deep pyrosequencing (UDPS) is used to identify rare sequence variants. The sequence depth is influenced by several factors including the error frequency of PCR and UDPS. This study investigated the characteristics and source of errors in raw and cleaned UDPS data. UDPS of a 167-nucleotide fragment of the HIV-1 SG3Δenv plasmid was performed on the Roche/454 platform. The plasmid was diluted to one copy, PCR amplified and subjected to bidirectional UDPS on three occasions. The dataset consisted of 47,693 UDPS reads. Raw UDPS data had an average error frequency of 0.30% per nucleotide site. Most errors were insertions and deletions in homopolymeric regions. We used a cleaning strategy that removed almost all indel errors, but had little effect on substitution errors, which reduced the error frequency to 0.056% per nucleotide. In cleaned data the error frequency was similar in homopolymeric and non-homopolymeric regions, but varied considerably across sites. These site-specific error frequencies were moderately, but still significantly, correlated between runs (r = 0.15–0.65) and between forward and reverse sequencing directions within runs (r = 0.33–0.65). Furthermore, transition errors were 48-times more common than transversion errors (0.052% vs. 0.001%; p<0.0001). Collectively the results indicate that a considerable proportion of the sequencing errors that remained after data cleaning were generated during the PCR that preceded UDPS. A majority of the sequencing errors that remained after data cleaning were introduced by PCR prior to sequencing, which means that they will be independent of platform used for next-generation sequencing. The transition vs. transversion error bias in cleaned UDPS data will influence the detection limits of rare mutations and sequence variants.

59 BASIC BIOLOGICAL SCIENCES↗

New active asteroid 313P/Gibbs

We present initial observations of the newly discovered active asteroid 313P/Gibbs (formerly P/2014 S4), taken to characterize its nucleus and comet-like activity. The central object has a radius ∼0.5 km (geometric albedo 0.05 assumed). We find no evidence for secondary nuclei and set (with qualifications) an upper limit to the radii of such objects near 20 m, assuming the same albedo. Both aperture photometry and a morphological analysis of the ejected dust show that mass-loss is continuous at rates ∼0.2–0.4 kg s{sup −1}, inconsistent with an impact origin. Large dust particles, with radii ∼50–100 μm, dominate the optical appearance. At 2.4 AU from the Sun, the surface equilibrium temperatures are too low for thermal or desiccation stresses to be responsible for the ejection of dust. No gas is spectroscopically detected (limiting the gas mass-loss rate to <1.8 kg s{sup −1}). However, the protracted emission of dust seen in our data and the detection of another episode of dust release near perihelion, in archival observations from 2003, are highly suggestive of an origin by the sublimation of ice. Coincidentally, the orbit of 313P/Gibbs is similar to those of several active asteroids independently suspected to be ice sublimators, including P/2012 T1, 238P/Read, and 133P/Elst–Pizarro, suggesting that ice is abundant in the outer asteroid belt.

79 ASTRONOMY AND ASTROPHYSICS↗

Strategies and limitations for fluorescence detection of XAFS at high flux beamlines

The issue of detecting the XAFS signal from dilute samples is discussed in detail with the aim of making best use of high flux beamlines that provide up to 10 13 photons -1 . Various detection methods are compared, including filters with slits, solid state detectors, crystal analyzers and combinations of these. These comparisons rely on simulations that use experimentally determined parameters. It is found that inelastic scattering places a fundamental limit on detection, and that it is important to take proper account of the polarization dependence of the signals. The combination of a filter–slit system with a solid state detector is a promising approach. With an optimized system good performance can be obtained even if the total count rate is limited to 10 7 Hz. Detection schemes with better energy resolution can help at the largest dilutions if their collection efficiency and count rate limits can be improved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE FREQUENCY OF LOW-MASS EXOPLANETS. II. THE 'PERIOD VALLEY'

Radial-velocity planet search campaigns are now beginning to detect low-mass 'Super-Earth' planets, with minimum masses M sin i{approx}< 10 M{sub +}. Using two independently developed methods, we have derived detection limits from nearly four years of the highest-precision data on 24 bright, stable stars from the Anglo-Australian Planet Search. Both methods are more conservative than a human analyzing an individual observed data set, as is demonstrated by the fact that both techniques would detect the radial-velocity signals announced as exoplanets for the 61 Vir system in 50% of trials. There are modest differences between the methods which can be recognized as arising from particular criteria that they adopt. What both processes deliver is a quantitative selection process such that one can use them to draw quantitative conclusions about planetary frequency and orbital parameter distribution from a given data set. Averaging over all 24 stars, in the period range P< 300 days and the eccentricity range 0.0 < e < 0.6, we could detect 99% of planets with velocity amplitudes K{approx}> 7.1 m s{sup -1}. For the best stars in the sample, we are able to detect or exclude planets with K{approx}> 3 m s{sup -1}, corresponding to minimum masses of 8 M{sub +} (P = 5 days) or 17 M{sub +} (P = 50 days). Our results indicate that the observed 'period valley', a lack of giant planets (M > 100 M{sub +}) with periods between 10 and 100 days, is indeed real. However, for planets in the mass range 10-100 M{sub +}, our results suggest that the deficit of such planets may be a result of selection effects.

79 ASTRONOMY AND ASTROPHYSICS↗

Atomically sharp domain walls in an antiferromagnet

The interest in understanding scaling limits of magnetic textures such as domain walls spans the entire field of magnetism from its physical fundamentals to applications in information technologies. Here, we explore antiferromagnetic CuMnAs in which imaging by x-ray photoemission reveals the presence of magnetic textures down to nanoscale, reaching the detection limit of this established microscopy in antiferromagnets. We achieve atomic resolution by using differential phase-contrast imaging within aberration-corrected scanning transmission electron microscopy. We identify abrupt domain walls in the antiferromagnetic film corresponding to the Néel order reversal between two neighboring atomic planes. Our work stimulates research of magnetic textures at the ultimate atomic scale and sheds light on electrical and ultrafast optical antiferromagnetic devices with magnetic field–insensitive neuromorphic functionalities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High level tritiated water monitoring by Bremsstrahlung counting using a silicon drift detector

The β-ray induced X-ray spectrometry (BIXS) is a promising technique to monitor the tritium concentration in a fuel cycle of a fusion reactor. For in-situ measurements of high level tritiated water by Bremsstrahlung counting, the characteristics of a low-noise silicon drift detector (SDD) have been examined at the Tritium Laboratory Karlsruhe (TLK). In static measurements with constant sample volume and tritium concentration, the Bremsstrahlung spectra of tritiated water samples in a concentration range of 0.02 to 15 MBq/ml have been obtained. The volume has been kept constant at 5 cm{sup 3}. The observed spectra are well above the noise threshold. In addition to X-rays induced by β-rays, the spectra feature X-ray fluorescence peaks of the surrounding materials. No indications of memory effects have been observed. A linear relation between the X-ray intensity and the tritium concentration was obtained and the lower detection limit of the setup has been determined to 1 MBq ml{sup -1}, assessed by the Curie criterion. In addition, the spectra obtained experimentally could be reproduced with high agreement by Monte-Carlo simulations using the GEANT4-tool-kit. It was found that the present detection system is applicable to non-invasive measurements of high-level tritiated water and the SDD is a convenient tool to detect the low energy Bremsstrahlung X-rays. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Detection of Optically Faint GEO Debris

There have been extensive optical surveys for debris at geosynchronous orbit (GEO) conducted with meter-class telescopes, such as those conducted with MODEST (the Michigan Orbital DEbris Survey Telescope, a 0.6-m telescope located at Cerro Tololo in Chile), and the European Space Agency's 1.0-m space debris telescope (SDT) in the Canary Islands. These surveys have detection limits in the range of 18th or 19th magnitude, which corresponds to sizes larger than 10 cm assuming an albedo of 0.175. All of these surveys reveal a substantial population of objects fainter than R = 15th magnitude that are not in the public U.S. Satellite Catalog. To detect objects fainter than 20th magnitude (and presumably smaller than 10 cm) in the visible requires a larger telescope and excellent imaging conditions. This combination is available in Chile. NASA's Orbital Debris Program Office has begun collecting orbital debris observations with the 6.5-m (21.3-ft diameter) "Walter Baade" Magellan telescope at Las Campanas Observatory. The goal is to detect objects as faint as possible from a ground-based observatory and begin to understand the brightness distribution of GEO debris fainter than R = 20th magnitude.

Seitzer, P.↗

Sensitive detection of formaldehyde using an interband cascade laser near 3.6 μm

Here, we report the development of a formaldehyde (H 2 CO) trace gas sensor using a continuous wave (CW), thermoelectrically-cooled (TEC), distributed-feedback interband cascade laser (DFB-ICL) at 3.6 μm. Wavelength modulation spectroscopy was used to detect the second harmonic spectra of a strong H 2 CO absorption feature centered at 2778.5 cm -1 (3599 nm) in its ν 1 fundamental vibrational band. A compact and novel multipass cell (7.6-cm physical length and 32-ml sampling volume) was implemented to achieve an effective optical path length of 3.75 m. A minimum detection limit of 6 parts per billion (ppb) at an optimum gas pressure of 200 Torr was achieved with a 1-s data acquisition time. An Allan-Werle deviation analysis was performed to investigate the long-term stability of the sensor system and a 1.5 ppb minimum detectable concentration could be achieved by averaging up to 140 s. Absorption interference eeffects from atmospheric H 2 O (2%) and CH 4 (5 ppm) were also analyzed in this work and proved to be insignificant for the current sensor configuration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

pH-Mediated Colorimetric and Luminescent Sensing of Aqueous Nitrate Anions by a Platinum(II) Luminophore@Mesoporous Silica Composite

Increased levels of nitrate (NO 3 – ) in the environment can be detrimental to human health. Herein, we report a robust, cost-effective, and scalable, hybrid material-based colorimetric/luminescent sensor technology for rapid, selective, sensitive, and interference-free in situ NO 3 – detection. These hybrid materials are based on a square-planar platinum(II) salt [Pt(tpy)Cl]PF6 (tpy = 2,2';6',2''-terpyridine) supported on mesoporous silica. The platinum salt undergoes a vivid change in color and luminescence upon exposure to aqueous NO 3 – anions at pH ≤ 0 caused by substitution of the PF6– anions by aqueous NO 3 – . This change in photophysics of the platinum salt is induced by a rearrangement of its crystal lattice that leads to an extended Pt···Pt···Pt interaction, along with a concomitant change in its electronic structure. Furthermore, incorporating the material into mesoporous silica enhances the surface area and increases the detection sensitivity. A NO 3 – detection limit of 0.05 mM (3.1 ppm) is achieved, which is sufficiently lower than the ambient water quality limit of 0.16 mM (10 ppm) set by the United States Environmental Protection Agency. The colorimetric/luminescence of the hybrid material is highly selective to aqueous NO 3 – anions in the presence of other interfering anions, suggesting that this material is a promising candidate for the rapid NO 3 – detection and quantification in practical samples without separation, concentration, or other pretreatment steps.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detection of small atom numbers through image processing

We demonstrate improved detection of small trapped atomic ensembles through advanced postprocessing and optimal analysis of absorption images. A fringe-removal algorithm reduces imaging noise to the fundamental photon-shot-noise level and proves beneficial even in the absence of fringes. A maximum-likelihood estimator is then derived for optimal atom-number estimation in well-localized ensembles and is applied to real experimental data to measure the population differences and intrinsic atom shot noise between spatially separated ensembles each comprising between 10 and 2000 atoms. The combined techniques improve our signal-to-noise ratio by a factor of 3, to a minimum resolvable population difference of 17 atoms, close to our ultimate detection limit.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cl atom recombination on silicon oxy-chloride layers deposited on chamber walls in chlorine-oxygen plasmas

Chlorine atom recombination coefficients were measured on silicon oxy-chloride surfaces deposited in a chlorine inductively coupled plasma (ICP) with varying oxygen concentrations, using the spinning wall technique. A small cylinder embedded in the walls of the plasma reactor chamber was rapidly rotated, repetitively exposing its surface to the plasma chamber and a differentially pumped analysis chamber housing a quadruple mass spectrometer for line-of-sight desorbing species detection, or an Auger electron spectrometer for in situ surface analysis. The spinning wall frequency was varied from 800 to 30 000 rpm resulting in a detection time, t (the time a point on the surface takes to rotate from plasma chamber to the position facing the mass or Auger spectrometer), of {approx}1-40 ms. Desorbing Cl{sub 2}, due to Langmuir-Hinshelwood (LH) Cl atom recombination on the reactor wall surfaces, was detected by the mass spectrometer and also by a pressure rise in one of the differentially pumped chambers. LH Cl recombination coefficients were calculated by extrapolating time-resolved desorption decay curves to t = 0. A silicon-covered electrode immersed in the plasma was either powered at 13 MHz, creating a dc bias of -119 V, or allowed to electrically float with no bias power. After long exposure to a Cl{sub 2} ICP without substrate bias, slow etching of the Si wafer coats the chamber and spinning wall surfaces with an Si-chloride layer with a relatively small amount of oxygen (due to a slow erosion of the quartz discharge tube) with a stoichiometry of Si:O:Cl = 1:0.38:0.38. On this low-oxygen-coverage surface, any Cl{sub 2} desorption after LH recombination of Cl was below the detection limit. Adding 5% O{sub 2} to the Cl{sub 2} feed gas stopped etching of the Si wafer (with no rf bias) and increased the oxygen content of the wall deposits, while decreasing the Cl content (Si:O:Cl = 1:1.09:0.08). Cl{sub 2} desorption was detectable for Cl recombination on the spinning wall surface coated with this layer, and a recombination probability of {gamma}{sub Cl} = 0.03 was obtained. After this surface was conditioned with a pure oxygen plasma for {approx}60 min, {gamma}{sub Cl} increased to 0.044 and the surface layer was slightly enriched in oxygen fraction (Si:O:Cl = 1:1.09:0.04). This behavior is attributed to a mechanism whereby Cl LH recombination occurs mainly on chlorinated oxygen sites on the silicon oxy-chloride surface, because of the weak Cl-O bond compared to the Cl-Si bond.

36 MATERIALS SCIENCE↗

A Sensitive VLA Search for Small-Scale Glycine Emission Toward OMC-1

We have conducted a deep Q-band (lambda-7 mm) search with the Very Large Array (VLA) toward OMC-1 for the lowest energy conformation (conformer I) of glycine (NH2CH2COOH) in four rotational transitions: the 6(sub 15)- 5(sub 14), 6(sub 24)-5(sub 23), 7(sub 17- 6(sub 16), and 7(sub 07)-6(sub 06). Our VLA observations sample the smallest-scale structures to date in the search for glycine toward OMC-1. No glycine emission features were detected. Thus if glycine exists in OMC-1, either it is below our detection limit, or it is more spatially extended than other large molecules in this source, or it is primarily in its high energy form (conformer II). Our VLA glycine fractional abundance limits in OMC-1 are comparable to those determined from previous IRAM 30m measurements -- somewhat better or worse depending on the specific source model -- and the entire approximately 1 foot primary beam of the VLA was searched while sensitive to an areal spatial scale approximately 150 times smaller than the 24 inch beam of the IRAM single-element telescope. In the course of this work, we detected and imaged the 4(sub 14)-3(sub 13) A and E transitions of methyl formate (HCOOCH3) and also the 2(sub 02) - 1(sub 01) transition of formic acid (HCOOH). Since formic acid is a possible precursor to glycine, our glycine limits and formic acid results provide a constraint on this potential formation chemistry route for glycine in OMC-1.

Hollis, J. M.↗

Chemical Sensor Development and Antibacterial Activities Based on Polyaniline/Gemini Surfactants for Environmental Safety

The polyaniline doped novel anionic gemini surfactant (PANI/GS) was chemically synthesized by a micellar polymerization process and then characterized in details by X-ray powder diffractometry, scanning electron microscopy, and FTIR spectroscopy. The results show the presence of polyaniline in the emeraldine base was formed by doping with gemini surfactant. The thermal properties of the composites were studied by carrying out thermal gravimetric analysis. The PANI/GS were found to be soluble in common organic solvents such as chloroform as well as DMSO. The antibacterial activity of the obtained PANI/GS was also evaluated against Gram positive bacteria Bacillus subtilis, Gram negative bacteria Escherichia coli and antibiotics (Amoxicillin) using the agar plate. The antibacterial study showed that the PANI/GS was found to be most effective against both B. subtilis and E. coli respectively which was significant compared to the amoxicillin. Beside that thin-layer of PANI/GS onto glassy carbon electrode (GCE) was fabricated with conducting 5% nafion coating agents to fabricate a sensitive and selective Cd{sup 2+} ionsic sensor in short response time into the phosphate buffer phase. The fabricated cationic-sensor was exhibited higher sensitivity, large-dynamic concentration ranges, long-term stability, and improved electrochemical performances towards Cd{sup 2+} ions. The calibration plot is linear (r{sup 2}, 0.9799) over the large Cd{sup 2+} concentration ranges (10.0 nM–1.0 mM). The sensitivity and detection limit is calculated as 2.324 µA µM{sup −1}cm{sup −2} and 6.85 nM (signal-to-noise ratio, at a SNR of 3) respectively. These novel efforts are intiated a well-known method for significant cationic sensor development with directly fabricated nanocomposite onto GCE for the detection of hazardous toxins in ecological and environmental fields in huge scales. Graphical Abstract: .

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Hidden photons in connection to dark matter

Light extra U(1) gauge bosons, so called hidden photons, which reside in a hidden sector have attracted much attention since they are a well motivated feature of many scenarios beyond the Standard Model and furthermore could mediate the interaction with hidden sector dark matter. We review limits on hidden photons from past electron beam dump experiments including two new limits from such experiments at KEK and Orsay. In addition, we study the possibility of having dark matter in the hidden sector. A simple toy model and different supersymmetric realisations are shown to provide viable dark matter candidates in the hidden sector that are in agreement with recent direct detection limits.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗