Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diffraction limited”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Study of Fluid Flow Control in Protein Crystallization using Strong Magnetic Fields

An important component in biotechnology, particularly in the area of protein engineering and rational drug design is the knowledge of the precise three-dimensional molecular structure of proteins. The quality of structural information obtained from X-ray diffraction methods is directly dependent on the degree of perfection of the protein crystals. As a consequence, the growth of high quality macromolecular crystals for diffraction analyses has been the central focus for biochemists, biologists, and bioengineers. Macromolecular crystals are obtained from solutions that contain the crystallizing species in equilibrium with higher aggregates, ions, precipitants, other possible phases of the protein, foreign particles, the walls of the container, and a likely host of other impurities. By changing transport modes in general, i.e., reduction of convection and sedimentation, as is achieved in "microgravity", researchers have been able to dramatically affect the movement and distribution of macromolecules in the fluid, and thus their transport, formation of crystal nuclei, and adsorption to the crystal surface. While a limited number of high quality crystals from space flights have been obtained, as the recent National Research Council (NRC) review of the NASA microgravity crystallization program pointed out, the scientific approach and research in crystallization of proteins has been mainly empirical yielding inconclusive results. We postulate that we can reduce convection in ground-based experiments and we can understand the different aspects of convection control through the use of strong magnetic fields and field gradients. Whether this limited convection in a magnetic field will provide the environment for the growth of high quality crystals is still a matter of conjecture that our research will address. The approach exploits the variation of fluid magnetic susceptibility with concentration for this purpose and the convective damping is realized by appropriately positioning the crystal growth cell so that the magnetic susceptibility force counteracts terrestrial gravity. The general objective is to test the hypothesis of convective control using a strong magnetic field and magnetic field gradient and to understand the nature of the various forces that come into play. Specifically we aim to delineate causative factors and to quantify them through experiments, analysis and numerical modeling. Once the basic understanding is obtained, the study will focus on testing the hypothesis on proteins of pyruvate dehydrogenase complex (PDC), proteins E1 and E3. Obtaining high crystal quality of these proteins is of great importance to structural biologists since their structures need to be determined. Specific goals for the investigation are: 1. To develop an understanding of convection control in diamagnetic fluids with concentration gradients through experimentation and numerical modeling. Specifically solutal buoyancy driven convection due to crystal growth will be considered. 2. To develop predictive measures for successful crystallization in a magnetic field using analyses and numerical modeling for use in future protein crystal growth experiments. This will establish criteria that can be used to estimate the efficacy of magnetic field flow damping on crystallization of candidate proteins. 3. To demonstrate the understanding of convection damping by high magnetic fields to a class of proteins that is of interest and whose structure is as yet not determined. 4. To compare quantitatively, the quality of the grown crystals with and without a magnetic field. X-ray diffraction techniques will be used for the comparative studies. In a preliminary set of experiments, we studied crystal dissolution effects in a 5 Tesla magnet available at NASA Marshall Space Flight Center (MSFC). Using a Schlieren setup, a 1mm crystal of Alum (Aluminum-Potassium Sulfate) was introduced in a 75% saturated solution and the resulting dissolution plume was observed. The experiment was conducted both in the presence and absence of a magnetic field gradient. The magnet produces a gradient field of approx. 1 Tesla2/cm. Image analysis of the recorded images indicated an enhanced plume velocity that was of the order of the measurement limit. For this experiment, both the gradient and gravity fields are in the same direction resulting in an enhanced effective gravity that tends to accelerate the observed plume velocity. While the results are not conclusive, pending further tests, it clearly points out the inadequacy of the MSFC magnet for conducting protein crystallization experiments and the need for a stronger magnet. In spacebased experiments, however, where the gravitational effects are small, only a weak magnetic field will be required to control or mitigate the effects of convective contamination.

Ramachandran, Narayanan↗

Preliminary results Skylab experiment TO27 optical contamination in space

Current results from the TO27 experiment which was performed on the first two Skylab missions are presented. The purpose of the experiment was to determine the change in optical properties of various transmissive windows, mirrors, and diffraction gratings caused by the deposition of contaminants found about the orbital assembly and to measure the sky brightness background caused by solar illumination of particulate contaminants. The sample array system containing 248 optical surfaces and exposed outside the orbital workshop did not collect any significant contaminants. Only trace amounts of surface deposited contaminants have been seen, in all cases the measurement was near the limiting sensitivity of the instrument. Unfortunate performance compromises and the relative cleanliness of the assembly on the anti-solar side appeared to place the amount of available surface contaminants near the limiting sensitivity of the sample array. Mass spectroscopy on the trace contaminants show the presence of high molecular weight species, up to 773 amu. The data suggests the presence of condensed aromatics.

Muscari, J. A.↗

Diffraction analysis of Doppler signal characteristics for a cross-beam laser Doppler velocimeter

Based on scalar diffraction theory, single particle scattering characteristics for a cross-beam laser Doppler velocimeter (LDV) have been computed for different particle sizes under varied instrumentation configurations. The modulating component of the scattered signal has been shown to depend upon particle size, shape, and collecting aperture for a given probe volume fringe spacing. Experimental verifications of some of the predictions are presented, and some of the limitations using an LDV as a particle sizing instrument are discussed.

Robinson, D. M.↗

Narrow bandgap semiconducting silicides: Intrinsic infrared detectors on a silicon chip

Work done during the final report period is presented. The main technical objective was to achieve epitaxial growth on silicon of two semiconducting silicides, ReSi2 and CrSi2. ReSi2 thin films were grown on (001) silicon wafers by vacuum evaporation of rhenium onto hot substrates in ultrahigh vacuum. The preferred epitaxial relationship was found to be ReSi2(100)/Si(001) with ReSi2(010) parallel to Si(110). The lattice matching consists of a common unit mesh of 120 A(sup 2) area, and a mismatch of 1.8 percent. Transmission electron microscopy revealed the existence of rotation twins corresponding to two distinct but equivalent azimuthal orientations of the common unit mesh. MeV He(+) backscattering spectrometry revealed a minimum channeling yield of 2 percent for an approximately 1,500 A thick film grown at 650 C. Although the lateral dimension of the twins is on the order of 100 A, there is a very high degree of alignment between the ReSi2(100) and the Si(001) planes. Highly oriented films of CrSi2 were grown on (111) silicon substrates, with the matching crystallographic faces being CrSi2(001)/Si(111). The reflection high-energy electron diffraction (RHEED) patterns of the films consist of sharp streaks, symmetrically arranged. The predominant azimuthal orientation of the films was determined to be CrSi2(210) parallel to Si(110). This highly desirable heteroepitaxial relationship has been obtained previously by others; it may be described with a common unit mesh of 51 A(sup 2) and mismatch of 0.3 percent. RHEED also revealed the presence of limited film regions of a competing azimuthal orientation, CrSi2(110) parallel to Si(110). A channeling effect for MeV He(+) ions was not found for this material. Potential commercial applications of this research may be found in silicon-integrated infrared detector arrays. Optical characterizations showed that semiconducting ReSi2 is a strong absorber of infrared radiation, with the adsorption constant increasing above 2 x 10(exp 4) cm(sup -1) for photon energies above 0.2 eV. CrSi2 is of potential utility for detection at photon energies above approximately 0.3 eV.

Mahan, John E.↗

Structured-groove phase gratings for control and optimization of the spectral efficiency

Phase gratings are used as dispersers in a variety of imaging spectroscopic instruments. However, conventional phase gratings provide limited spectral range and flexibility to fully optimize instrument performance for challenging applications. Presented here is a new design method that tailors and optimizes the spectral efficiency by introducing an arbitrary structure into the grating groove profile.

diffraction gratings↗

Arcus: The X-Ray Grating Spectrometer Explorer

Arcus will be proposed to the NASA Explorer program as a free-flying satellite mission that will enable high-resolution soft X-ray spectroscopy (8-50 Angstroms) with unprecedented sensitivity-effective areas of greater than 500 sq cm and spectral resolution greater than 2500. The Arcus key science goals are (1) to determine how baryons cycle in and out of galaxies by measuring the effects of structure formation imprinted upon the hot gas that is predicted to lie in extended halos around galaxies, groups, and clusters, (2) to determine how black holes influence their surroundings by tracing the propagation of out-flowing mass, energy and momentum from the vicinity of the black hole out to large scales and (3) to understand how accretion forms and evolves stars and circumstellar disks by observing hot infalling and outflowing gas in these systems. Arcus relies upon grazing incidence silicon pore X-ray optics with the same 12m focal length (achieved using an extendable optical bench) that will be used for the ESA Athena mission. The focused X-rays from these optics will then be diffracted by high-efficiency off-plane reflection gratings that have already been demonstrated on sub-orbital rocked flights, imaging the results with flight-proven CCD detectors and electronics. The power and telemetry requirements on the spacecraft are modest. The majority of mission operations will not be complex, as most observations will be long (~100 ksec), uninterrupted, and pre-planned, although there will be limited capabilities to observe targets of opportunity, such as tidal disruption events or supernovae with a 3-5 day turnaround. After the end of prime science, we plan to allow guest observations to maximize the science return of Arcus to the community.

Instrumentation↗

Size estimates of Titan's aerosols based on Voyager high-phase-angle images

Limits on the physical properties of the scattering haze near the top of Titan's atmosphere are derived from data obtained from seven high-phase-angle images from Voyager 1 and 2. From the ratio of the intensities observed at two different high phase angles, an estimate can be made of the forward-scattering lobe of the single-scattering phase function. Comparing the forward-scattering estimate with diffraction lobes from particles of different radii, it is concluded that the average radius of the particles found in the upper few tenths of an optical depth exceeds 0.19 micron. Judging from data observed at four different phase angles, the haze particles probably have a refractive index near 1.6 and a mean size of about 0.5 micron, if the widths of their diffraction peaks are close to those for equal-volume spheres. However, the highly polarizing nature of the particles over a broad wavelength-bandpass (Tomasko and Smith, 1982; West et al, 1983) combined with their forward-scattering behavior makes it very unlikely that the particles are spherical. The nonsphericity contributes to the uncertainty about the radii of the particles, but it is thought that the average radius is several tenths of a micron.

Rages, K.↗

Spectrometer Technology Development for Far-Infrared Line Surveys

The objective of this proposal was to build and demonstrate a new direct-detection diffraction grating concept and couple it to an array of bolometers. The spectrometer was to be built around a parallel-plate waveguide diffraction grating, WaFIRS: Waveguide Far-InfraRed Spectrometer. The grating is two dimensional in nature, which provides a compact configuration to suit NASA s needs for cryogenic spectrometers for future opportunities, such as infrared/submillimeter spectrometers for a suborbital balloon platform, for SOFIA, for SPICA (a Japanese satellite), and for SAFIR. Our goal was to build a spectrometer (Z-Spec) for 1.0 - 1.5 mm and demonstrate spectral resolution, throughput, and background-limited performance. This grant would partially cover the expenses and we were subsequently awarded a second grant, NAGS-12788, to complete the project. We have one-year received a no-cost extension on NAG.5-12788, to be completed in 3/31/06.

Glenn, Jason↗

Analysis of near-field Cassegrain reflector - Plane wave versus element-by-element approach

A near-field Cassegrain reflector (NFCR) is an effective way to magnify a small phased array into a much larger-aperture antenna for limited scan applications. Traditionally the pattern analysis of NFCR is based on a plane wave approach, which simplifies the computation tremendously, but fails to provide design information about the most critical component of the whole antenna system, the feed array. Currently available computers make it possible to calculate the pattern of an NFCR by a more exact element-by-element approach. Each element in the feed array is considered individually, and the diffraction pattern from the subreflector is calculated by the geometrical theory of diffraction (including uniform theories at the shadow boundaries). The field contributions from all elements are superimposed at the curved main reflector surface, and a physical-optics integration is performed to obtain the secondary pattern.

Houshmand, Bijan↗

X-Ray Diffraction on Mars: Scientific Discoveries Made by the CheMin Instrument

The Mars Science Laboratory Curiosity landed in Gale crater in August 2012 with the goal to identify and characterize habitable environments on Mars. Curiosity has been studying a series of sedimentary rocks primarily deposited in fluviolacustrine environments approximately 3.5 Ga. Minerals in the rocks and soils on Mars can help place further constraints on these ancient aqueous environments, including pH, salinity, and relative duration of liquid water. The Chemistry and Mineralogy (CheMin) X-ray diffraction and X-ray fluorescence instrument on Curiosity uses a Co X-ray source and charge-coupled device detector in transmission geometry to collect 2D Debye-Scherrer ring patterns of the less than 150 micron size fraction of drilled rock powders or scooped sediments. With an angular range of approximately 2.52deg 20 and a 20 resolution of approximately 0.3deg, mineral abundances can be quantified with a detection limit of approximately 1-2 wt. %. CheMin has returned quantitative mineral abundances from 16 mudstone, sandstone, and aeolian sand samples so far. The mineralogy of these samples is incredibly diverse, suggesting a variety of depositional and diagenetic environments and different source regions for the sediments. Results from CheMin have been essential for reconstructing the geologic history of Gale crater and addressing the question of habitability on ancient Mars.

Rampe, E. B.↗

Predesign of diamond turned refractive/diffractive elements for IR objectives

Diffractive lenses have arrived. Literally hundreds of papers have been published and technology impact reports have been written about the exciting addition of a new tool for the lens designer. Sophisticated computer programs have been developed to aid in the optimization of these diffractive phase profiles for a wide variety of applications. Now, several fabrication methods are being pursued to produce these diffractive elements economically. The best known process is the etching of a multi-level relief grating, known as binary optics. This process uses sets of computer generated lithographic masks. Another, more recently developed method is Dry Photopolymer Embossing (DPE). This replication process uses master holograms. And now, diamond turning is being applied for the machining of these elements. Diamond turning is especially well suited for infrared optics. As any process has advantages and limitations, so has diamond turning. These advantages and limitations are discussed and general guidelines are presented to aid the designer and systems engineer in the project predesign stage.

Riedl, Max J.↗

Investigation of Abnormal Grain Growth in a Friction Stir Welded and Spin-Formed Al-Li Alloy 2195 Crew Module

In order to improve manufacturing efficiency and reduce structural mass and costs in the production of launch vehicle structures, NASA is pursuing a wide-range of innovative, near-net shape manufacturing technologies. A technology that combines friction stir welding (FSW) and spin-forming has been applied to manufacture a single-piece crew module using Aluminum-Lithium (AL-Li) Alloy 2195. Plate size limitations for Al-Li alloy 2195 require that two plates be FSW together to produce a spin-forming blank of sufficient size to form the crew module. Subsequent forming of the FSW results in abnormal grain growth (AGG) within the weld region upon solution heat treatment (SHT), which detrimentally impacts strength, ductility, and fracture toughness. The current study seeks to identify microstructural factors that contribute to the development of AGG. Electron backscatter diffraction (EBSD) was used to correlate driving forces for AGG, such as stored energy, texture, and grain size distributions, with the propensity for AGG. Additionally, developmental annealing treatments prior to SHT are examined to reduce or eliminate the occurrence of AGG by promoting continuous, or uniform, grain growth

Tayon, Wesley A.↗

Telescope-optical system performance analysis for the Cryogenic Limb Array Etalon Spectrometer (CLAES) on the Upper Atmospheric Research Satellite

A first-order performance analysis of the CLAES telescope-optical system is presented. The experiment involves the passive measurement of earth-limb radiance over a 10-60 km tangent altitude range, and is based on a solid Fabry-Perot spectrometer which provides spectral resolution of 0.25/cm for atmospheric emission spectroscopy over the 3.5-12 micron IR range. The optical system is required to provide a high degree of off-axis rejection and stray-light control, primarily to suppress intense emission from the earth surface. The astigmatism and other geometric aberrations are corrected by a secondary mirror which produces an excellent image of the primary one, allowing for location of a diffraction control or Lyot stop. The off-axis scattering performance of the telescope is examined in terms of the mirror scatter coefficient and point source rejection ratio. A mirror bidirectional reflectance distribution function of 0.0001 at 1 deg with a 1/theta-squared roll-off between 1 and 0.2 deg is realizable based on recent measurements. This results in an off-axis radiance term that is generally small in comparison with the system-limiting NER.

Roche, A. E.↗

Holographic, particle imaging and data reduction at Spectron Development Laboratores

Spectron has been deeply involved in the development and use of a wide variety of particle and flow diagnostic, electro optical instruments. Holography and imaging systems have played an important role in this work, but the extraction of data from images and holograms have always presented a limit to their use. Systems and techniques were devised to speed up and automate the extraction of data from holographic and conventional interferograms, particle images and holograms, and other types of optical flow visualization techniques. An IBM/AI based image analyzer was developed that is capable of automatically analyzing many useful image types including interferograms. A key feature of this system is the low total cost of the required hardware. In the particle field work, a commercial diffraction field analyzer was adopted to the image reconstructed from a hologram. This could expand the use of holography in particle diagnostics greatly.

Trolinger, James D.↗

Rapid solidification of polymorphic transition metals induced by nanosecond laser pulses

An Nd-YAG laser giving 5 ns, 266 nm pulses was used to melt and subsequently quench thin, pure metallic films on a liquid Al/Al2O3 substrate at 10 to the 10th - 10 to the 12th K/s. Transmission electron microscopy together with electron diffraction was used to study the competitive nucleation and growth behavior of the crystals from the undercooled melt. In the case of Fe and Co, the high-temperature bcc and fcc structures were retained after laser quenching. Ti and Zr in spite of the structural similarities exhibit different preferences for nucleation from the undercooled melt. In all the metals the solid-state transformations were completely suppressed and the crystal growth was found to be limited by the collisional frequency of the atoms onto the growing interface.

Vitta, Satish↗

Design and Performance of A High Resolution Micro-Spec: An Integrated Sub-Millimeter Spectrometer

Micro-Spec is a compact sub-millimeter (approximately 100 GHz--1:1 THz) spectrometer which uses low loss superconducting microstrip transmission lines and a single-crystal silicon dielectric to integrate all of the components of a diffraction grating spectrometer onto a single chip. We have already successfully evaluated the performance of a prototype Micro-Spec, with spectral resolving power, R=64. Here we present our progress towards developing a higher resolution Micro-Spec, which would enable the first science returns in a balloon flight version of this instrument. We describe modifications to the design in scaling from a R=64 to a R=256 instrument, as well as the ultimate performance limits and design concerns when scaling this instrument to higher resolutions.

spectrometer↗

Chemical vapor deposition growth

A laboratory type CVD reactor system with a vertical deposition chamber and sample pedestal heated by an external RF coil has been extensively modified by installation of mass flow controllers, automatic process sequence timers, and special bellows-sealed air-operated valves for overall improved performance. Various film characterization procedures, including classical metallography, SEM analyses, X ray diffraction analyses, surface profilometry, and electrical measurements (resistivity, carrier concentration, mobility, spreading resistance profiles, and minority-carrier lifetime by the C-V-t method) area used to correlate Si sheet properties with CVD parameters and substrate properties. Evaluation procedures and measurements are given. Experimental solar cell structures were made both in epitaxial Si sheet (on sapphire substrates) and in polycrystalline material on alumina substrates, the former to provide an indication of what might be an upper limit on performance of the latter. Preliminary results are given, as obtained in cell structures not specially designed to allow for the unique properties of the sheet material, and fabricated in material known to be far from optimum for photovoltaic performance. Low power conversion efficiencies have been obtained in the epitaxial as well as the polycrystalline Si sheet.

Ruth, R. P.↗

Achromatic Focal Plane Mask for Exoplanet Imaging Coronagraphy

Recent advances in coronagraph technologies for exoplanet imaging have achieved contrasts close to 1e10 at 4 lambda/D and 1e-9 at 2 lambda/D in monochromatic light. A remaining technological challenge is to achieve high contrast in broadband light; a challenge that is largely limited by chromaticity of the focal plane mask. The size of a star image scales linearly with wavelength. Focal plane masks are typically the same size at all wavelengths, and must be sized for the longest wavelength in the observational band to avoid starlight leakage. However, this oversized mask blocks useful discovery space from the shorter wavelengths. We present here the design, development, and testing of an achromatic focal plane mask based on the concept of optical filtering by a diffractive optical element (DOE). The mask consists of an array of DOE cells, the combination of which functions as a wavelength filter with any desired amplitude and phase transmission. The effective size of the mask scales nearly linearly with wavelength, and allows significant improvement in the inner working angle of the coronagraph at shorter wavelengths. The design is applicable to almost any coronagraph configuration, and enables operation in a wider band of wavelengths than would otherwise be possible. We include initial results from a laboratory demonstration of the mask with the Phase Induced Amplitude Apodization coronagraph.

Achromatic↗