Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

High-resolution and site-specific scanning spreading resistance microscopy and its applications to silicon devices

Due to the continuous reduction of the critical dimensions of semiconductor devices, it becomes very important to know the two dimensional (2D) doping profile for improving device performance. Scanning spreading resistance microscopy (SSRM) performed in high vacuum is a powerful technique for quantitative 2D-doping profiling, with high spatial resolution and wide dynamic range of carrier concentration, as well as capability of site-specific analysis for accurate position. In this paper, we review SSRM applications to source/drain engineering in Si devices and their correlation with device characteristics by demonstrating several case studies. Direct observation of (110)/(100) CMOSFETs clarified significant differences between both pFETs and nFETs on (110) and (100) silicon substrates, revealing 2D channeling effect of boron ion implantation in pFETs; as well as silicidation impact on junction leakage-current characteristics in nFETs. Furthermore, our sample-preparation breakthrough enables site-specific SSRM characterization within 60 nm ultra thin samples and therefore failure analysis of real SRAM devices, demonstrating the high potential of SSRM technology for further device scaling and for failure analysis.

36 MATERIALS SCIENCE↗

K-shell spectroscopy of silicon ions as diagnostic for high electric fields

We developed a detection scheme, capable of measuring X-ray line shape of tracer ions in {mu}m thick layers at the rear side of a target foil irradiated by ultra intense laser pulses. We performed simulations of the effect of strong electric fields on the K-shell emission of silicon and developed a spectrometer dedicated to record this emission. The combination of a cylindrically bent crystal in von Hamos geometry and a CCD camera with its single photon counting capability allows for a high dynamic range of the instrument and background free spectra. This approach will be used in future experiments to study electric fields of the order of TV/m at high density plasmas close to solid density.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correlated evolution of barrier capacitance charging, generation, and drift currents and of carrier lifetime in Si structures during 25 MeV neutrons irradiation

The in situ examination of barrier capacitance charging, of generation and drift currents, and of carrier lifetime in Si structures during 25 MeV neutrons irradiation has been implemented to correlate radiation induced changes in carrier recombination, thermal release, and drift characteristics and to clarify their impact on detector performance. It has been shown that microwave probed photo-conductivity technique implemented in contact-less and distant manner can be a powerful tool for examination in wide dynamic range of carrier lifetime modified by radiation defects and for rather precise prediction of detector performance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SuperADAM: Upgraded polarized neutron reflectometer at the Institut Laue-Langevin

A new neutron reflectometer SuperADAM has recently been built and commissioned at the Institut Laue-Langevin, Grenoble, France. It replaces the previous neutron reflectometer ADAM. The new instrument uses a solid state polarizer/wavelength filter providing a highly polarized (up to 98.6%) monochromatic neutron flux of 8 Multiplication-Sign 10{sup 4} n cm{sup -2} s{sup -1} with monochromatization {Delta}{lambda}/{lambda}= 0.7% and angular divergence {Delta}{alpha}= 0.2 mrad. The instrument includes both single and position sensitive detectors. The position sensitive detector allows simultaneous measurement of specular reflection and off-specular scattering. Polarization analysis for both specular reflection and off-specular scattering is achieved using either mirror analyzers or a {sup 3}He spin filter cell. High efficiency detectors, low background, and high flux provides a dynamic range of up to seven decades in reflectivity. Detailed specifications and the instrument capabilities are illustrated with examples of recently collected data in the fields of thin film magnetism and thin polymer films.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of a DSSSD detector with radioactive sources

The energy calibration of a DSSSD is carried out with the spectra produced by a {sup 207}Bi conversion electron source, a {sup 137}Cs gamma source and a {sup 239}Pu/{sup 241}Am/{sup 244}Cm triple alpha source, as well as employing a precision pulse generator in the whole dynamic range. Multiplicity and coincidence of signals in different strips for the same event are also studied.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anomalous optical switching and thermal hysteresis during semiconductor-metal phase transition of VO{sub 2} films on Si substrate

We present a detailed infrared study of the semiconductor-to-metal transition (SMT) in a vanadium dioxide (VO{sub 2}) film deposited on silicon wafer. The VO{sub 2} phase transition is studied in the mid-infrared region by analyzing the transmittance and the reflectance measurements, and the calculated emissivity. The reflectance has been measured in two configurations: from the side of the VO{sub 2} film and from that of Si wafer. The results show a strong asymmetry between the emissivity in the two configurations, and the fact that the emissivity dynamic range from the silicon side is twice as large than that from the VO{sub 2} side. The temperature behaviour of the emissivity during the SMT put into evidence the phenomenon of the anomalous absorption in VO{sub 2}, which has been explained by applying the Maxwell Garnett effective medium approximation theory.

36 MATERIALS SCIENCE↗

A novel self-sensing technique for tapping-mode atomic force microscopy

This work proposes a novel self-sensing tapping-mode atomic force microscopy operation utilizing charge measurement. A microcantilever coated with a single piezoelectric layer is simultaneously used for actuation and deflection sensing. The cantilever can be batch fabricated with existing micro electro mechanical system processes. The setup enables the omission of the optical beam deflection technique which is commonly used to measure the cantilever oscillation amplitude. Due to the high amount of capacitive feedthrough in the measured charge signal, a feedforward control technique is employed to increase the dynamic range from less than 1 dB to approximately 35 dB. Experiments show that the conditioned charge signal achieves excellent signal-to-noise ratio and can therefore be used as a feedback signal for atomic force microscopy imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A bootstrapped, low-noise, and high-gain photodetector for shot noise measurement

We presented a low-noise, high-gain photodetector based on the bootstrap structure and the L-C (inductance and capacitance) combination. Electronic characteristics of the photodetector, including electronic noise, gain and frequency response, and dynamic range, were verified through a single-frequency Nd:YVO{sub 4} laser at 1064 nm with coherent output. The measured shot noise of 50 μW laser was 13 dB above the electronic noise at the analysis frequency of 2 MHz, and 10 dB at 3 MHz. And a maximum clearance of 28 dB at 2 MHz was achieved when 1.52 mW laser was illuminated. In addition, the photodetector showed excellent linearities for both DC and AC amplifications in the laser power range between 12.5 μW and 1.52 mW.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Color-based tracking of plasma dust particles

Color-based tracking to observe agglomeration of deposited particles inside a compact planar magnetron during plasma discharge was done by creating high dynamic range (HDR) images of photos captured by a Pentax K10D digital camera. Carbon erosion and redeposition was also monitored using the technique. The HDR images were subjected to a chromaticity-based constraint discoloration inside the plasma chamber indicating film formation or carbon redeposition. Results show that dust deposition occurs first near the evacuation pumps due to the pressure gradient and then accumulates at the positively charged walls of the chamber. This method can be applied to monitor dust formation during dusty plasma experiments without major modification of plasma devices, useful especially for large fusion reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effective terahertz-to-near-infrared photon conversion in slant-stripe-type periodically poled LiNbO{sub 3}

We propose a slant-stripe-type periodically poled LiNbO{sub 3} crystal for the construction of a practical quasi-phase-matched (QPM) device for terahertz (THz) detection. A minimum detectable THz-wave energy of 25 fJ/pulse is demonstrated, and a linear input-output property with a dynamic range of 60 dB is achieved. The working frequency range of 0.15 THz for THz detection is obtained, and the central frequency of the sensitivity can be controlled by the design of the periodically poled structure. THz detection using this QPM device is a promising technique that may allow the detection of a coherent THz photon.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A direct measurement of the electronic structure of Si nanocrystals and its effect on optoelectronic properties

Since reports that silicon nanocrystals (Si-NCs) can exhibit direct transition emission, the silicon laser field is at a juncture where the importance of this discovery needs to be evaluated. Most theoretical models predicted a monotonic increase in the bandgap and experimental information currently available on the electronic structure at the Γ valley of these promising materials is circumstantial as it is obtained from emission measurements where competing non-radiative relaxation and recombination processes only provide an incomplete picture of the electronic structure of Si-NCs. Optical absorption, the most immediate probe of the electronic structure beyond the band-edges, showing the evolution of the Γ valley states with nanocrystal size has not been measured. Here, we show such measurements, performed with high dynamic range, allowing us to observe directly the effect of crystal size on the Γ valley splitting far above the band-edges. We show that the splitting is 100 s of meV more pronounced than predicted by pseudo potential calculations and Luttinger-Kohn model. We also show that ultrafast red-shifting emission can be observed in plasma enhanced chemical vapor deposition prepared Si-NCs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High fidelity qubit readout with the superconducting low-inductance undulatory galvanometer microwave amplifier

We describe the high fidelity dispersive measurement of a superconducting qubit using a microwave amplifier based on the Superconducting Low-inductance Undulatory Galvanometer (SLUG). The SLUG preamplifier achieves gain of 19 dB and yields a signal-to-noise ratio improvement of 9 dB over a state-of-the-art HEMT amplifier. We demonstrate a separation fidelity of 99% at 700 ns compared to 59% with the HEMT alone. The SLUG displays a large dynamic range, with an input saturation power corresponding to 700 photons in the readout cavity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Non-Geiger mode single photon detector with multiple amplification and gain control mechanisms

A new type of single photon detector, Multiple Amplification Gain with Internal Control (MAGIC), is proposed and analyzed using Monte Carlo simulations based on a physical model of the device. The MAGIC detector has two coupled amplification mechanisms, avalanche multiplication and bipolar gain, and the net gain is regulated by a built-in feedback mechanism. Compared to conventional Geiger mode single photon avalanche detectors (SPADs), the MAGIC detector produces a much greater single photon detection efficiency of nearly 100%, low bit-error-ratio for single photon signals, and a large dynamic range. All these properties are highly desirable for applications that require single photon sensitivity and are absent for conventional Geiger-mode SPADs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Strong environmental coupling in a Josephson parametric amplifier

We present a lumped-element Josephson parametric amplifier designed to operate with strong coupling to the environment. In this regime, we observe broadband frequency dependent amplification with multi-peaked gain profiles. We account for this behavior using the “pumpistor” model which allows for frequency dependent variation of the external impedance. Using this understanding, we demonstrate control over the complexity of gain profiles through added variation in the environment impedance at a given frequency. With strong coupling to a suitable external impedance, we observe a significant increase in dynamic range, and large amplification bandwidth up to 700 MHz giving near quantum-limited performance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Displacement damage effects on CMOS APS image sensors induced by neutron irradiation from a nuclear reactor

The experiments of displacement damage effects on CMOS APS image sensors induced by neutron irradiation from a nuclear reactor are presented. The CMOS APS image sensors are manufactured in the standard 0.35 μm CMOS technology. The flux of neutron beams was about 1.33 × 10{sup 8} n/cm{sup 2}s. The three samples were exposed by 1 MeV neutron equivalent-fluence of 1 × 10{sup 11}, 5 × 10{sup 11}, and 1 × 10{sup 12} n/cm{sup 2}, respectively. The mean dark signal (K{sub D}), dark signal spike, dark signal non-uniformity (DSNU), noise (V{sub N}), saturation output signal voltage (V{sub S}), and dynamic range (DR) versus neutron fluence are investigated. The degradation mechanisms of CMOS APS image sensors are analyzed. The mean dark signal increase due to neutron displacement damage appears to be proportional to displacement damage dose. The dark images from CMOS APS image sensors irradiated by neutrons are presented to investigate the generation of dark signal spike.

36 MATERIALS SCIENCE↗

Methodological demonstration of laser beam pointing control for space gravitational wave detection missions

In space laser interferometer gravitational wave (G.W.) detection missions, the stability of the laser beam pointing direction has to be kept at 10 nrad/√Hz. Otherwise, the beam pointing jitter noise will dominate the noise budget and make the detection of G.W. impossible. Disturbed by the residue non-conservative forces, the fluctuation of the laser beam pointing direction could be a few μrad/√Hz at frequencies from 0.1 mHz to 10 Hz. Therefore, the laser beam pointing control system is an essential requirement for those space G.W. detection missions. An on-ground test of such beam pointing control system is performed, where the Differential Wave-front Sensing technique is used to sense the beams pointing jitter. An active controlled steering mirror is employed to adjust the beam pointing direction to compensate the jitter. The experimental result shows that the pointing control system can be used for very large dynamic range up to 5 μrad. At the interested frequencies of space G.W. detection missions, between 1 mHz and 1 Hz, beam pointing stability of 6 nrad/√Hz is achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of the hard x-ray background in backlit pinhole imagers

Hard x-rays from laser-produced hot electrons (>10 keV) in backlit pinhole imagers can give rise to a background signal that decreases signal dynamic range in radiographs. Consequently, significant uncertainties are introduced to the measured optical depth of imaged plasmas. Past experiments have demonstrated that hard x-rays are produced when hot electrons interact with the high-Z pinhole substrate used to collimate the softer He-α x-ray source. Results are presented from recent experiments performed on the OMEGA-60 laser to further study the production of hard x-rays in the pinhole substrate and how these x-rays contribute to the background signal in radiographs. Radiographic image plates measured hard x-rays from pinhole imagers with Mo, Sn, and Ta pinhole substrates. The variation in background signal between pinhole substrates provides evidence that much of this background comes from x-rays produced in the pinhole substrate itself. A Monte Carlo electron transport code was used to model x-ray production from hot electrons interacting in the pinhole substrate, as well as to model measurements of x-rays from the irradiated side of the targets, recorded by a bremsstrahlung x-ray spectrometer. Inconsistencies in inferred hot electron distributions between the different pinhole substrate materials demonstrate that additional sources of hot electrons beyond those modeled may produce hard x-rays in the pinhole substrate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-gated single-photon detection module with 110 ps transition time and up to 80 MHz repetition rate

We present the design and characterization of a complete single-photon counting module capable of time-gating a silicon single-photon avalanche diode with ON and OFF transition times down to 110 ps, at repetition rates up to 80 MHz. Thanks to this sharp temporal filtering of incoming photons, it is possible to reject undesired strong light pulses preceding (or following) the signal of interest, allowing to increase the dynamic range of optical acquisitions up to 7 decades. A complete experimental characterization of the module highlights its very flat temporal response, with a time resolution of the order of 30 ps. The instrument is fully user-configurable via a PC interface and can be easily integrated in any optical setup, thanks to its small and compact form factor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗