Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electrical System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Preparation for Hollow Cathode Testing for the Advanced Electric Propulsion System at NASA Glenn Research Center

NASA Glenn Research Center is performing activities to support the unique needs of hollow cathode development and testing for the Advanced Electric Propulsion System (AEPS). Three existing vacuum facilities have been outfitted as cathode test facilities, and each will serve a different role in upcoming testing. Vacuum Facility 67 is being developed to serve as a long-duration test facility for the Engineering Development Unit cathode, which is to be delivered by the AEPS contractor. It will feature a thruster-like magnetic field simulator and cold-cycle capability via a liquid nitrogen-cooled cold plate. Vacuum Facility 17 is being developed as a test facility for short- to medium-duration experiments in order to provide auxiliary support for the long-duration testing. It will feature a magnetic field simulator but not cold-cycling. Finally, Vacuum Facility 1 will be a high-pumping speed cathode development environment, and will feature an array of plasma and temperature diagnostics. In addition to the facility preparation work, a new cathode, referred to as the Mark II, has been designed. The Mark II is an evolution of the Technology Demonstration Unit cathodes that better evokes the geometry, fabrication, and construction of the forthcoming Engineering Development Unit. This cathode serves as a transition between the Technology Demonstration Unit cathodes used during early thruster development and the forthcoming Engineering Development Unit cathodes. It will be used as a means of verifying the new test facilities prior to arrival of Engineering Development Unit hardware. Details of the Mark II design and key features are presented, as well as details of future work to be performed.

Advanced Electric Propulsion System (AEPS)↗

A modular electric power system test bed for small spacecraft

In the new climate of smaller, faster, and cheaper space science satellites, a new power system topology has been developed at the NASA Lewis Research Center. This new topology is based on a series connected boost converter (SCBC) and can greatly affect the size, weight, fault tolerance, and cost of any small spacecraft using photovoltaic solar arrays. The paper presents electric power system design factors and requirements as background information. The series connected boost converter topology is discussed and several advantages over existing technologies are illustrated. Besides being small, lightweight, and efficient, this topology has the added benefit of inherent fault tolerance. A positive ground power system test bed has been developed for the TROPIX spacecraft program. Performance of the SCBC in the test bed is described in detail. SCBC efficiencies of 95 percent to 98 percent have been measured. Finally, a modular, photovoltaic regulator 'kit' concept is presented. Two SCBC's are used to regulate solar array charging of batteries and to provide 'utilitytype' power to the user loads. The kit's modularity will allow a spacecraft electric power system to be built from off-the-shelf hardware; resulting in smaller, faster, and cheaper spacecraft.

Button, Robert M.↗

Communications for the Future Electric Grid: Systems and Implications

As the operation of the electric grid continues to become more automated, the associated increase in sensors and systems places increasing demands for fast response, cybersecure communications. This paper presents a review of advances underway in communications and networking technologies that may be implemented to meet these future electric grid requirements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Soft-Fault Detection Technologies Developed for Electrical Power Systems

The NASA Glenn Research Center, partner universities, and defense contractors are working to develop intelligent power management and distribution (PMAD) technologies for future spacecraft and launch vehicles. The goals are to provide higher performance (efficiency, transient response, and stability), higher fault tolerance, and higher reliability through the application of digital control and communication technologies. It is also expected that these technologies will eventually reduce the design, development, manufacturing, and integration costs for large, electrical power systems for space vehicles. The main focus of this research has been to incorporate digital control, communications, and intelligent algorithms into power electronic devices such as direct-current to direct-current (dc-dc) converters and protective switchgear. These technologies, in turn, will enable revolutionary changes in the way electrical power systems are designed, developed, configured, and integrated in aerospace vehicles and satellites. Initial successes in integrating modern, digital controllers have proven that transient response performance can be improved using advanced nonlinear control algorithms. One technology being developed includes the detection of "soft faults," those not typically covered by current systems in use today. Soft faults include arcing faults, corona discharge faults, and undetected leakage currents. Using digital control and advanced signal analysis algorithms, we have shown that it is possible to reliably detect arcing faults in high-voltage dc power distribution systems (see the preceding photograph). Another research effort has shown that low-level leakage faults and cable degradation can be detected by analyzing power system parameters over time. This additional fault detection capability will result in higher reliability for long-lived power systems such as reusable launch vehicles and space exploration missions.

Button, Robert M.↗

Edge Wear of the Advanced Electric Propulsion System Pole Covers

This work presents a summary of the first wear test of the 12 kW Advanced Electric Propulsion System (AEPS) focused on characterizing the erosion of the edges and side walls of the thruster pole covers. Testing was performed with the AEPS Engineering Test Unit 2 (ETU-2) thruster and accumulated approximately 325 hours of operation at the 600 V/12 kW condition with the magnetic field strength set to 75% of its nominal value. Thruster performance was invariant throughout the wear test for all thruster throttle conditions and was found to be equal to previous measurements. Contrary to past results, inner front pole cover erosion rates were invariant to magnetic field strength at the 600 V/12 kW condition and no erosion was measured on the outer front pole cover. The erosion profile of the downstream inner front pole cover faces was continuous across the cover indicating no significant change in erosion process at the pole cover edges. Side wall erosion was only detected on the cathode-facing surfaces of the inner front pole cover and was equal in magnitude to the rates measured on the adjacent downstream edges. Taken together, these results suggest that erosion of the pole cover edges and sidewalls is driven by cathode-borne ions and will ultimately not impact AEPS life estimates.

Hall thrusters↗

Development of an 8-cm engineering model thruster system

Electric propulsion has been shown to offer major advantages over the techniques currently employed for the control of earth satellites. For a user to realize these advantages, however, requires the availability of a proven, operationally flight-ready propulsion system. Currently an Engineering Model of an 8-cm ion thruster propulsion system is under development. The system includes the thruster unit with its associated reservoir, thruster gimbaling subsystem, and power processing unit. This paper describes the EM System with special emphasis on hardware design and system performance.

Herron, B. G.↗

Renewable Electricity Futures Study - Volume 4: Bulk Electric Power Systems. Operations and Transmission Planning

The Renewable Electricity Futures (RE Futures) Study investigated the challenges and impacts of achieving very high renewable electricity generation levels in the contiguous United States by 2050. The analysis focused on the sufficiency of the geographically diverse U.S. renewable resources to meet electricity demand over future decades, the hourly operational characteristics of the U.S. grid with high levels of variable wind and solar generation, and the potential implications of deploying high levels of renewables in the future. RE Futures focused on technical aspects of high penetration of renewable electricity; it did not focus on how to achieve such a future through policy or other measures. Given the inherent uncertainties involved with analyzing alternative long-term energy futures as well as the multiple pathways that might be taken to achieve higher levels of renewable electricity supply, RE Futures explored a range of scenarios to investigate and compare the impacts of renewable electricity penetration levels (30%–90%), future technology performance improvements, potential constraints to renewable electricity development, and future electricity demand growth assumptions. RE Futures was led by the National Renewable Energy Laboratory (NREL) and the Massachusetts Institute of Technology (MIT). Learn more at the RE Futures website. http://www.nrel.gov/analysis/re_futures/

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electric Power System for High Altitude UAV Technology Survey

Electric powertrain technologies with application to high altitude Unmanned Aerial Vehicles (UAV) are assessed. One hundred twenty five solar electric UAV configurations and missions were simulated. Synergistic design opportunities were investigated with the premise that specific benefits may be realized, for example, if a single component can serve multiple functions, such as a battery being used for energy storage as well as for a structural component of the aircraft. For each UAV mission simulation, the airframe structure, powertrain configuration (type of solar cells, energy storage options) and performance baseline (1997 or 2001) were specified. It has been found that the use of the high efficiency (multijunction) solar cells or the use of the synergistic amorphous silicon solar cell configuration yields aircraft that can accomplish the majority of the missions of interest for any latitude between 0 deg and 55 deg, hence, a single versatile aircraft can be constructed and implemented to accomplish these missions.

Source record↗

A New Design Approach to Mitigating the Effect of Parasitics in Capacitive Wireless Power Transfer Systems for Electric Vehicle Charging

This paper introduces a new design approach to mitigate the effect of parasitic capacitances and achieve high performance in large air-gap capacitive wireless power transfer (WPT) systems for electric vehicle (EV) charging. In a capacitive WPT system for EVs, the vehicle chassis and roadway introduce multiple parasitic capacitances that can overwhelm the coupling capacitance and severely degrade power transfer and efficiency. The proposed approach addresses this challenge by employing split-inductor matching networks, which allow the complex network of parasitic capacitances to be simplified into an equivalent four-capacitance model. The shunt capacitances of this model are directly utilized as the matching network capacitors, hence, absorbing the parasitic capacitances and eliminating the need for discrete high-voltage capacitors. A systematic procedure is developed to accurately measure the equivalent capacitances of the model, enabling the system's performance to be reliably predicted. The proposed approach is used to design two 6.78-MHz 12-cm air-gap prototype capacitive WPT systems with capacitor-free matching networks. The first system transfers up to 590 W using 150-cm 2 square coupling plates and achieves an efficiency of 88.4%. The second prototype system transfers up to 1217 W using 118-cm 2 circular coupling plates, achieving a power transfer density of 51.6 kW/m 2 . The measured output power profiles of the two systems match well with their predicted counterparts, validating the proposed design approach.

33 ADVANCED PROPULSION SYSTEMS↗

Qualitative Description of Electric Power System Future States

This work proposes a common basis for the simulation and evaluation of transactive systems. Using existing literature, a qualitative survey of the future states of the electric power system was conducted. Forces exerting influence on the state of the power system, called “drivers,” were identified. Specific future states in the literature were identified and classified into five general groups, and the effects of twelve previously identified drivers were assessed for each individual future state in the literature. Relationships between the five general future states were defined through a Venn diagram and system evolutions were demonstrated through notional narratives and corresponding paths through the diagram. A relational measure of the complexity and extent of the change implied by each future state was also created.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Systematic Benchmarking of Diagnostic Technologies for an Electrical Power System

Automated health management is a critical functionality for complex aerospace systems. A wide variety of diagnostic algorithms have been developed to address this technical challenge. Unfortunately, the lack of support to perform large-scale V&V (verification and validation) of diagnostic technologies continues to create barriers to effective development and deployment of such algorithms for aerospace vehicles. In this paper, we describe a formal framework developed for benchmarking of diagnostic technologies. The diagnosed system is the Advanced Diagnostics and Prognostics Testbed (ADAPT), a real-world electrical power system (EPS), developed and maintained at the NASA Ames Research Center. The benchmarking approach provides a systematic, empirical basis to the testing of diagnostic software and is used to provide performance assessment for different diagnostic algorithms.

Kurtoglu, Tolga↗

DOE 10658 Project Sensitivity-Driven Wide Area Protection (SWAP) Coordination Tools for IBRs

Utilities have seen a rapid increase in solar, wind, and battery energy storage systems that interconnect to their electric system through inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well-known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protects the inverter’s sensitive power electronics devices from damage from conditions such as overcurrent. This results in a low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufacturers and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of focusing on one issue, this report looks broadly at all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspectives from different utility SMEs via questionnaire, the report summarizes the gathered data and internal experiences.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermionic reactor electric propulsion system requirements.

Results of mission analysis, system analysis and mission engineering studies to find a single nuclear electric propulsion (NEP) system which would be applicable for a broad range of unmanned outer planet missions. The NEP system studied uses an in-core nuclear thermionic reactor as the electric power source and mercury bombardment ion engines for propulsion. Many requirements, which are imposed on the NEP system by the mission, were determined from the studies in the process of trying to find a single NEP system for many missions. It is concluded that a single thermionic reactor NEP system could be useful for a broad range of unmanned outer planet missions. The thermionic reactor NEP system should have a power level in the range from 70 to 120 kWe, a system specific weight of approximately 30 kg/kWe, and a full power output capability of 20,000 hr.

Mondt, J. F.↗

Space Station Freedom electric power system availability study

The results are detailed of follow-on availability analyses performed on the Space Station Freedom electric power system (EPS). The scope includes analyses of several EPS design variations, these are: the 4-photovoltaic (PV) module baseline EPS design, a 6-PV module EPS design, and a 3-solar dynamic module EPS design which included a 10 kW PV module. The analyses performed included: determining the discrete power levels that the EPS will operate at upon various component failures and the availability of each of these operating states; ranking EPS components by the relative contribution each component type gives to the power availability of the EPS; determining the availability impacts of including structural and long-life EPS components in the availability models used in the analyses; determining optimum sparing strategies, for storing space EPS components on-orbit, to maintain high average-power-capability with low lift-mass requirements; and analyses to determine the sensitivity of EPS-availability to uncertainties in the component reliability and maintainability data used.

Turnquist, Scott R.↗

Methods for Probabilistic Fault Diagnosis: An Electrical Power System Case Study

Health management systems that more accurately and quickly diagnose faults that may occur in different technical systems on-board a vehicle will play a key role in the success of future NASA missions. We discuss in this paper the diagnosis of abrupt continuous (or parametric) faults within the context of probabilistic graphical models, more specifically Bayesian networks that are compiled to arithmetic circuits. This paper extends our previous research, within the same probabilistic setting, on diagnosis of abrupt discrete faults. Our approach and diagnostic algorithm ProDiagnose are domain-independent; however we use an electrical power system testbed called ADAPT as a case study. In one set of ADAPT experiments, performed as part of the 2009 Diagnostic Challenge, our system turned out to have the best performance among all competitors. In a second set of experiments, we show how we have recently further significantly improved the performance of the probabilistic model of ADAPT. While these experiments are obtained for an electrical power system testbed, we believe they can easily be transitioned to real-world systems, thus promising to increase the success of future NASA missions.

Ricks, Brian W.↗

Architecture for Co-Simulation of Transportation and Distribution Systems with Electric Vehicle Charging at Scale in the San Francisco Bay Area

This work describes the Grid-Enhanced, Mobility-Integrated Network Infrastructures for Extreme Fast Charging (GEMINI) architecture for the co-simulation of distribution and transportation systems to evaluate EV charging impacts on electric distribution systems of a large metropolitan area and the surrounding rural regions with high fidelity. The current co-simulation is applied to Oakland and Alameda, California, and in future work will be extended to the full San Francisco Bay Area. It uses the HELICS co-simulation framework to enable parallel instances of vetted grid and transportation software programs to interact at every model timestep, allowing high-fidelity simulations at a large scale. This enables not only the impacts of electrified transportation systems across a larger interconnected collection of distribution feeders to be evaluated, but also the feedbacks between the two systems, such as through control systems, to be captured and compared. The findings are that with moderate passenger EV adoption rates, inverter controls combined with some distribution system hardware upgrades can maintain grid voltages within ANSI C.84 range A limits of 0.95 to 1.05 p.u. without smart charging. However, EV charging control may be required for higher levels of charging or to reduce grid upgrades, and this will be explored in future work.

24 POWER TRANSMISSION AND DISTRIBUTION↗