Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy Utilization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Deconstructing Biomass [part of The frontiers of energy]

Great strides have been made over the past century in our ability to harness energy sources, leading to profound transformations — both good and bad — in society. Looking at the energy system of today, it is clear that meeting the energy needs of the world now and in the years to come requires the concerted efforts of many different actors across a range of technologies and approaches. In this Feature, ten leading experts in energy research share their vision of what challenges their respective fields need to address in the coming decades. The issues being faced are diverse and multifaceted, from the search for better materials for fuels, to the design of energy policy and markets for the developing world. However, a common theme emerges: changes to adapt and improve our energy system are greatly needed. As a result, by improving our mutual understanding of the issues faced by each area of energy research, these changes can happen more smoothly, efficiently and rapidly.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Potential of artificial intelligence in reducing energy and carbon emissions of commercial buildings at scale

Artificial intelligence has emerged as a technology to enhance productivity and improve life quality. However, its role in building energy efficiency and carbon emission reduction has not been systematically studied. This study evaluated artificial intelligence’s potential in the building sector, focusing on medium office buildings in the United States. A methodology was developed to assess and quantify potential emissions reductions. Key areas identified were equipment, occupancy influence, control and operation, and design and construction. Six scenarios were used to estimate energy and emissions savings across representative climate zones. Here we show that artificial intelligence could reduce cost premiums, enhancing high energy efficiency and net zero building penetration. Adopting artificial intelligence could reduce energy consumption and carbon emissions by approximately 8% to 19% in 2050. Combining with energy policy and low-carbon power generation could approximately reduce energy consumption by 40% and carbon emissions by 90% compared to business-as-usual scenarios in 2050.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dataset of low global warming potential refrigerant refrigeration system for fault detection and diagnostics

Abstract HVAC and refrigeration system fault detection and diagnostics (FDD) has attracted extensive studies for decades; however, FDD of supermarket refrigeration systems has not gained significant attention. Supermarkets consume around 50 kWh/ft 2 of electricity annually. The biggest consumer of energy in a supermarket is its refrigeration system, which accounts for 40%–60% of its total electricity usage and is equivalent to about 2%–3% of the total energy consumed by commercial buildings in the United States. Also, the supermarket refrigeration system is one of the biggest consumers of refrigerants. Reducing refrigerant usage or using environmentally friendly alternatives can result in significant climate benefits. A challenge is the lack of publicly available data sets to benchmark the system performance and record the faulted performance. This paper identifies common faults of supermarket refrigeration systems and conducts an experimental study to collect the faulted performance data and analyze these faults. This work provides a foundation for future research on the development of FDD methods and field automated FDD implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Global Building Occupant Behavior Database

This paper introduces a database of 34 field-measured building occupant behavior datasets collected from 15 countries and 39 institutions across 10 climatic zones covering various building types in both commercial and residential sectors. This is a comprehensive global database about building occupant behavior. The database includes occupancy patterns (i.e., presence and people count) and occupant behaviors (i.e., interactions with devices, equipment, and technical systems in buildings). Brick schema models were developed to represent sensor and room metadata information. The database is publicly available, and a website was created for the public to access, query, and download specific datasets or the whole database interactively. The database can help to advance the knowledge and understanding of realistic occupancy patterns and human-building interactions with building systems (e.g., light switching, set-point changes on thermostats, fans on/off, etc.) and envelopes (e.g., window opening/closing). With these more realistic inputs of occupants’ schedules and their interactions with buildings and systems, building designers, energy modelers, and consultants can improve the accuracy of building energy simulation and building load forecasting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Datasets of a Multizone Office Building under Different HVAC System Operation Scenarios

Abstract This study provides an open-source dataset of the measured weather data, building indoor data, and system data under the different test settings. The test building is the two-story Flexible Research Platform building at the US Department of Energy’s Oak Ridge National Laboratory, in Oak Ridge, Tennessee. Four heating tests and three cooling tests were conducted. The 1-min interval of weather, building indoor data, and system data from each test setting are provided. Actual weather data were collected from a weather station installed on the roof. This paper describes information on the test building and installed sensors, data collection method, and data validation. The provided dataset can be employed to understand HVAC system conditions and building indoor conditions under different HVAC system operations and the performance of building envelope without HVAC system operation using free-floating test data. Additionally, it can be used for empirical validation of the building energy modelling engine.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Plasma characteristics of single- and dual-electrode ion source systems utilized in low-energy ion extraction

Discharge characteristics in the upstream as well as in the downstream regions of a 50-eV positive ion beam were measured along the beam axis. Single- and dual-electrode configurations made of 0.1-mm diameter tungsten wires were tested. By varying the upstream discharge parameters, the shape of the sheath edge around the extractors, which can either be “planar” or “cylindrical,” can be controlled. The sheath eventually affected the simultaneous extraction of ions and neutralizing electrons. The dual-electrode configuration at the lower discharge current, revealed a homogeneous discharge downstream. At this condition, the edge of the sheath can be inferred to be “planar” which allowed the uniform extraction and propagation of low-energy ions at longer distances. The dual-electrode configuration was capable of transmitting low-energy ions up to 70 mm downstream.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of One- and Two-Variable Linear Regression Models and Classic Energy Intensity for Energy Performance Tracking of Two Manufacturing Sectors

We report manufacturing facilities consumed about 32% of total domestic energy in the United States in 2016. To evaluate the energy savings achieved through the implementation of energy conservation projects and to establish powerful arguments for future projects, accurate energy performance tracking methods are necessary. The classic energy intensity method (i.e., the ratio of annual total energy over annual total production) is the means most widely used to measure savings because it can be understood and calculated easily. This method considers the variation in production rates to some extent; however, it fundamentally assumes facilities' base energy consumption (energy consumption at zero production) to be zero, which rarely holds true. Furthermore, this method does not consider variations in other relevant parameters, such as weather conditions. Therefore, the regression models approach is commonly recommended to track energy performance improvements. However, because it requires more data and statistical expertise, the regression models approach has been adopted by only a few facilities, and many others suspect it is not worth the effort for their specific cases. For this reason, the improved accuracy this approach offers needs to be demonstrated. By analyzing 477 monthly energy (electricity and natural gas) data sets, this study quantitatively compared the accuracy of classic energy intensity, one-variable (production only) linear regression models, and two-variable (i.e., production and weather) linear regression models for two manufacturing sectors (primary metal and transportation equipment manufacturing). Results showed that significant improvements in accuracy were achieved with one-variable regression models when compared with the classic energy intensity method and with two-variable regression models when compared with one-variable regression models. These improvements were demonstrated using the p values of intercept, cooling degree days, and heating degree days. Based on these results, to achieve a good balance between accuracy improvements and resources requirements, one-variable (production only) linear regression models for electricity consumption and two-variable (production and heating degree days) linear regression models for natural gas consumption are recommended for both sectors in the case of limited resources. Lastly, facilities can also use the results to decide which approaches fit better in their cases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Harvesting from Ambient Energy: Designing Enabling Technologies for Sustainable Buildings

Electricity consumption in the commercial sector is forecasted to increase by 0.5% on an annual bases between 2017 to 2050. This is despite best design practices and adoption of more energy efficient resources for buildings. This increase is prevalent in miscellaneous electrical loads that studies have shown if their usage is tracked and conveyed to the occupant will result in up 34% consumption reduction. Diverse tools and research methodologies are being developed to track their location. This paper addresses one such method to identify the location of energy at the point of use using energy harvesting. The paper proposes a design process for magnetic flux harvesting around current carrying conductors of the electrical system in buildings for the purpose of powering sensors and/or for use as a triggering signal for energy consumption location in the built environment. Building on the electromagnetic induction theory, a relationship is developed between the size of the harvesting device and the total energy output. A prototype energy harvesting device based on the proposed data is built and tested through laboratory experiments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Budget-Constrained Sizing of Renewable and Energy Storage Systems for Farm-Scale Ammonia Production Within the Food-Energy-Water Nexus

In the transition toward sustainable agriculture, farms have emerged as eco-friendly pioneers, harnessing clean hybrid wind and solar systems to improve farm performance. A concern in this paradigm is the effective sizing of renewable energy systems to ensure optimal energy use within budget considerations. This research focuses on optimizing renewable energy sizing in small-scale ammonia production to meet specific farm demands and enhance local resilience, emphasizing the interplay between environmental and economic factors. These findings promise increased energy efficiency and sustainability in this innovative agricultural sector. Additionally, our approach considers small-scale ammonia plant needs and the dynamic relationships between ammonia, water, and farm demands. Simulations demonstrate substantial cost savings in farm electricity consumption. Specifically, scenarios with renewable energy integration in the farm can reduce at least 13% electricity cost compared to a grid-dependent system in the 15-year simulation.

ammonia↗

Instrumentation for Assessing DC Electrical Distribution Systems in Buildings

Direct current (DC) distribution systems is emerging as a favorable option over alternating current in buildings due to its energy and non-energy benefits (e.g., efficiency, resilience, safety). However, limited guidelines exist to evaluate the DC electrical distribution infrastructure. This paper aims to fill that gap by detailing our experience with metering a building-level electrical DC distribution system. Our case study is a DC microgrid at the Direct Energy Partners Research & Development facility located in Charlotte, North Carolina. This paper presents our approach, technical challenges, and lessons learned with DC metering and instrumentation.

buildings↗

Development of a Hybrid Single/Two-Phase Capillary-Based Micro-Cooler using Copper Inverse Opals Wick with Silicon 3D Manifold for High-Heat-Flux Cooling Application

Previously, we reported two-phase capillary-based cooling using narrow (200 to 1000 ..mu..m) heater bridge copper inverse opal (CIO) wicks with heat flux level of 1400 Wcm -2 and superheat ~ 10 degrees C. Here, we demonstrate the area scaling of the proposed technology to a large-area micro-cooler for high-heat-flux cooling of microprocessors and power electronics. We developed a hybrid single/two-phase micro-cooler that relies on capillary-wicking in a 25-..mu..m-thick CIO with an open silicon microchannel 3D-manifold for liquid delivery and vapor extraction, achieving a high heat flux ~ 400 Wcm -2 over a heated area of 10 x 10 mm 2 . For a range of inlet water flowrates from 5 to 60 g(min) -1 , we achieved total thermal resistances and vapor qualities of 0.68 cm 2 degrees CW -1 to 0.2 cm 2 degrees CW -1 and 0.55 to 0.12, respectively. The flowrates are 10x smaller than those of conventional single- or two-phase microchannel cooling technology. The corresponding two-phase thermal resistances ranges from 0.05 to 0.02 cm 2 degrees CW -1 with temperature superheat of 8 to 6 degrees C, respectively. While the overall performance of the large-area (10 x 10 mm 2 ) capillary-based micro-cooler degraded compared to the previous demonstration of the technology for a heated area of 5 x 5 mm 2 , however, preliminary CFD modeling indicates that an improved manifold design will be able to achieve comparable performance.

capillary flow↗