The Road to Los Alamos [Slides]
This report gives details about the author's academic journey and projects, including highlights from work at NASA.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
This report gives details about the author's academic journey and projects, including highlights from work at NASA.
To improve the realism of Fire PRA associated with fire progression and damage modeling or manual suppression, previous research by the Socio-Technical Risk Analysis (SoTeRiA) Research Laboratory at the University of Illinois at Urbana-Champaign focused on the development of an Integrated PRA (I-PRA) methodological framework for fire risk analysis in NPPs.
The geometric flexibility of additively manufactured metals and ceramics generates a very large and open design space that requires advanced modeling and simulation tools for physics simulations and the rigorous definition of design problems. This effort deploys artificial intelligence (AI) and machine learning (ML) algorithms to understand the design space, evaluate potential designs, and more efficiently generate optimized results. The Transformational Challenge Reactor (TCR) program is leveraging advances in several scientific areas—including materials, manufacturing, sensors and control systems, data analytics, and high-fidelity modeling and simulation—to accelerate the design, manufacturing, qualification, and deployment of advanced nuclear energy systems. Through a manufacturing-informed design approach, the TCR program seeks to integrate digital data for rapid nuclear innovation; accelerate the adoption of advances in manufacturing, materials, and computational sciences for nuclear applications; and dramatically reduce deployment costs and timelines for new nuclear reactor technologies. This report documents efforts under the TCR program to leverage advanced modeling and simulation techniques driven by AI/ML algorithms on high-performance computing (HPC) systems to yield more optimized TCR core designs. A multiphysics ML surrogate model was developed to run on the HPC architectures. The surrogate model is trained on high-fidelity simulation data of coupled neutronics and thermofluidics and is used to quickly evaluate thousands of candidate core designs in parallel, which drives the evolution of the cooling channel shapes to minimize temperature peaking and material stress. Outcomes from these activities provide design information and feedback into the core design efforts.
A preliminary analysis on a novel accident response system to diminish the severity of supercritical transients was conducted. The novel accident response system, called the instant shock arrest system, involves using electricity to heat the nuclear fuel at the onset of a large accidental reactivity insertion. This system is specifically designed for reactors with metallic fuel, such that the fuel is capable of conducting electricity, and being resistively heated. A reactor dynamics model of the advanced test reactor was created using the point kinetics equations and a linear reactivity feedback model to simulate how the system would effect the maximum fuel temperatures experienced during the transient. Transients with the instant shock arrest system were compare to those without it. It was found that the instant shock arrest system initially heated the fuel more than the unaffected transient but the negative reactivity inserted from such heating was enough to lower the maximum fuel temperature experienced during the transient. After simulating six different accident scenarios with reactivity insertions ranging from 0.5 \$ to 1.3 \$, it was found that the an optimal system response could reduce peak fuel temperatures during the transient by 3.5\% to 5\%. Furthermore, discussion was given on how the optimal system response could be obtained using relatively simple numerical optimization algorithms due to the smoothness of the optimization problem.
Over the past few years, the CTH multiphysics hydrocode has overhauled its software quality and testing processes, implementing current best practices in software quality and building a robust V&V test suite comprised of traditional hydrocode verification problems, including ASC Tri-Lab Test Suite and Enhanced Tri-Lab Test Suite problems, as well as validation problems for some of CTH’s most frequently used equations of state, materials models, and other key capabilities. Substantial progress towards building this new test suite was made in FY19 and FY20. In FY21, the test suite has been expanded to include verification and validation tests of the Steinberg-Guinan-Lund (ST) viscoplastic model and the Johnson Cook (JFRAC) fracture model. Additionally, two new verification tests were added, covering hydrodynamics and high explosive (HE) modeling capabilities: the Kidder Gaussian density problem and the Escape of HE Products (EHEP) problem from the Tri-Lab Test Suite. This report discusses each of these test problems in detail. Verification test results are compared to analytic solutions. Validation test results are compared to experimental data. Wherever possible, convergence or mesh refinement studies are included. Additionally, while implementing the Kidder verification problem, a bug was identified that affects the use of tables to initialize pressure or density in 1D or 2D calculations. A brief discussion of the bug and its fix is included. CTH demonstrates good performance overall on the new test suite problems. Simulation results showed good agreement with analytic solutions for the Kidder problem, with convergence rates ranging between 1.8 and sub-linear, and relatively good agreement for the EHEP problem, though convergence rates for pressure and density were nearly 0. The ST and JFRAC strain rate loading verification tests show good agreement with analytic solutions. Likewise, CTH simulation results show good agreement with experimental validation data, including Taylor rod impact testing, for the materials tested. Future V&V work will focus on adding 2D and 3D versions of existing verification tests as well as adding validation tests of other frequently used capabilities such as other fracture models.
The principal objective of this project was to synthesize core-shell heterostructures for solid oxide fuel cell cathodes using a molten salt solvent. In doing so, the main goals were split into a) to elucidate and understand the influence of molten salt chemistries to expeditiously synthesize perovskite type oxides for solid oxide fuel cells, b) provide a chemical framework for future molten salt syntheses of energy relevant ceramic materials, c) demonstrate and investigate the required parameters for the optimal core-shell synthesis and yield of La 0.6 Sr 0.4 Co 0.2 Fe 0.8 O 3 (LSCF) – La 0.8 Sr 0.2 MnO 3 (shell), and d) demonstrate improved cathode performance of core-shell LSCF-LSM compared to an LSCF cathode on symmetric cells. The results clearly show that a) the influence of the molten salt cation outweighs the anion in regards to product stoichiometry, b) molten salts should be tailored to balance cationic and anionic acidity for high product yield, c) high yield of core-shell nanoparticles can be achieved by optimal mass ratio between core to shell, dwell time in the salt, size ratio between core to shell, and mass ratio between overall powder to salt, and d) the core-shell LSCF-LSM cathodes have lower polarization resistances than LSCF at higher temperatures. More work is required to optimize core-shell cathode performance at lower temperatures. However, this work thus provided justification for using the molten salt synthesis for SOFC cathodes and provided insights into future material modifications for improved performance.
This is an addendum to the Sierra/SolidMechanics 5.8 User’s Guide that documents additional capabilities available only in alternate versions of the Sierra/SolidMechanics (Sierra/SM) code. These alternate versions are enhanced to provide capabilities that are regulated under the U.S. Department of State’s International Traffic in Arms Regulations (ITAR) export control rules. The ITAR regulated codes are only distributed to entities that comply with the ITAR export control requirements. The ITAR enhancements to Sierra/SM include material models with an energy-dependent pressure response (appropriate for very large deformations and strain rates) and capabilities for blast modeling. This document is an addendum only; the standard Sierra/SolidMechanics 5.8 User’s Guide should be referenced for most general descriptions of code capability and use.
The long-term operation (LTO) of nuclear power plants (NPP) beyond their original design life of 40 years can lead to more material damage associated with cyclic fatigue under thermal-mechanical loading cycles and associated long-term exposure of reactor material to the deleterious reactor-coolant environments. However, under this LTO condition, the reactor components can still safely operate but may require more frequent Nondestructive Evaluation (NDE) of reactor components. Requiring frequent NDE inspections may lead to frequent NPP shutdowns which can lead to power outages and additional NDE inspection cost-related economic loss. The economic loss can be minimized by reducing uncertainty in life estimation of safety-critical pressure boundary components and by implementing a more digital approach such as using upcoming digital-twin (DT) technology for predicting the structural states (e.g., time and location dependent inside/outside thickness temperature, stress, strain, plastic deformation, etc.) and associated fatigue life of a component in real time. The DT framework is based on limited experimental data, Artificial-intelligence (AI)-Machine-Learning (ML) and multiphysics-computationalmechanics such as finite element- (FE) based models. Given the real-time thermal-hydraulic process measurements from several existing plant sensors, the overall goal of the DT framework is to predict the cumulative usages factors or equivalent fatigue lives in real time and at any random 3D location of the components. This includes inaccessible locations such as inside the thickness or location of a component. This prediction can be at thousands to millions of 3D point clouds or locations like conventional FE-based models, but without running an FE model in real time.
This report presents the load following analysis of the “Holos-Quad” 10MWe micro-reactor design developed by HolosGen LLC. This analysis is focused on the Holos-Quad micro-reactor ability to match the changing grid demand at 10%/min rate. The control mechanisms for the plant are identified, simulated, and compared. Based on the comparison results, control strategy for load following of the Holos-Quad micro-reactor is developed. The control strategy and load following capabilities are demonstrated in a full-range down-and-up reactor power transient from 100% to 0% and back to 100% load at 10%/min rate. All calculations are carried out with Argonne’s Plant Dynamics Code.
This is an addendum to the Sierra/SolidMechanics 5.10 User’s Guide that documents additional capabilities available only in alternate versions of the Sierra/SolidMechanics (Sierra/SM) code. These alternate versions are enhanced to provide capabilities that are regulated under the U.S. Department of State’s International Traffic in Arms Regulations (ITAR) export control rules. The ITAR regulated codes are only distributed to entities that comply with the ITAR export control requirements. The ITAR enhancements to Sierra/SM include material models with an energy-dependent pressure response (appropriate for very large deformations and strain rates) and capabilities for blast modeling. This document is an addendum only; the standard Sierra/SolidMechanics 5.10 User’s Guide should be referenced for most general descriptions of code capability and use.
Abstract not provided.
To support design efforts for the Versatile Test Reactor (VTR) core assemblies, an experimental facility has been designed and constructed at Argonne National Laboratory to match the hydraulic flow conditions within the VTR’s primary heat transport system (PHTS). This facility, the Pressure drop Experimental Loop for Investigations of Core Assemblies in advanced Nuclear reactors, PELICAN, provides the ability to measure pressure drop across a full-scale fuel assembly containing prototypic axial reflectors, fuel, and plena components. The PELICAN facility was designed and built to offer maximum flexibility, allowing testing from short sub-sections all the way to the full-length core fuel assemblies. The report presents the high-level program objectives, a summary of the facility design, instrumentation, and control systems, and the testing procedure. The outcomes from facility characterization efforts and first test matrix results are then presented and then, finally, the conclusion contains a summary of the future work to be performed. This test facility was designed to match the hydraulic conditions of the flowing sodium in the VTR using water as a surrogate fluid. To do so, the water is elevated to a temperature of 110°C where its viscosity matches that of sodium, and with a 50-HP centrifugal pump, is capable of generating full scale flow rates to achieve prototypic Reynolds and Euler number flow conditions. To prevent boiling, the system is maintained at elevated pressure of at least 2.7-3.0 bar (40-44 psig). A set of 15 tests have been used to perform checkout activities in order to commission the device, survey the capabilities of PELICAN, and generate experimental data at isothermal conditions and over a range of flow rates up to 44 kg/s (700 GPM) to produce datasets used in the verification and validation of VTR design and modeling efforts. Initial testing focused on facility characterization, which assessed the operational capabilities of various control systems. The thermal control system was qualified, including the thermal response of the loop to the heat added by self- and auxiliary heaters, the chiller and heat exchanger systems for removing excess heat, and their coupled ability to maintain steady-state isothermal conditions as desired. Additionally, the pressure control system was verified to ensure necessary operating environments that promote pump health and prevent boiling of loop inventory at high temperatures could be met. With these systems in place, the first set of matrix tests have been carried out using orifice plates with inner diameters of 2.25-inches and 2.5-inches. Orifice plate flow behavior is well covered in scientific literature, and the results find good agreement with the measured pressure drop vs flow rate and those of theoretical predictions. This initial testing not only helps to validate the experiment, but it also produces a high quality data set for a geometry that is easily reproducible for simulations. Finally, the report is concluded with a discussion of the work to come and provides a snapshot of the test articles in the experimental pipeline whose designs are being inspired by the current designs from the VTR.
The Thermal Hydraulic Experimental Test Article (THETA) is a METL vessel experiment designed for testing and validating sodium fast reactor components and phenomena. THETA has been scaled using a non-dimensional Richardson number approach to represent temperature distributions during nominal and loss of flow conditions in a sodium fast reactor (SFR), this analysis was detailed in the THETA FY19 report. The facility is being constructed with versatility in mind, allowing for the installation of various immersion heaters, heat pipes, and heat exchangers without significant facility modification. THETA was designed in collaboration with systems code experts to inform the geometry and sensor placement to acquire the highest value code validation data.
The Pressure Drop Experimental Loop for Investigations of Core Assemblies in Advanced Nuclear Reactors, PELICAN, is a novel experimental facility designed and constructed to recreate the prototypic full scale hydraulic flow conditions for the Versatile Test Reactor (VTR) currently under development by the U.S. Department of Energy. To support VTR design efforts, PELICAN is used to replicate VTR’s primary heat transport system (PHTS) in the core assembly region. The measurement objectives for data generated from this test facility are to mimic the prototypic VTR assembly and to meet the validation needs for code calculations and simulations of the reference design for the VTR core. These objectives focus on the need to validate pressure drop results across the various segments of the fuel assembly, including the axial reflectors, fuel, and transition regions, as they relate directly to the pumping power and safety behavior of the reactor. In the following sections, the major milestones for the experimental work performed on PELICAN over the calendar year (CY) 2021 are presented. In the next section, we discuss the assembly and shakedown testing of the facility. In Section 3, an analysis of the errors in the major measurements is performed. In Section 4 and 5 we present the results from the first set of test articles placed inside the loop. The design of the remaining test articles as part of the full assembly are shown in Section 6 and the conclusion and path forward for the following year, CY22 is given in the final section.
The report is delivered as DOE-NE Cybersecurity Program Milestone M2CT-22IN1104014-Industry cybersecurity guidance adoption status. The milestone is specifically to document the process and the status of the efforts towards developing guidance in support of industry’s adoption of wireless communication technologies. To transform the operation of nuclear power plants, including domestic light-water reactors, advanced reactors, microreactors, and fission battery, for grid and non-grid applications, secure and resilient wireless capabilities are required. In addition, to realize new operational concepts such as autonomous operation and remote monitoring, advanced sensor, and instrumentation, wireless technology is essential. However, industry implementation is low, and there is no technical basis for how to understand and address potential risks for wireless communications for critical plant functions. A methodology with a technical basis for implementing secure wireless communication is crucial. This wireless adoption methodology is intended to assist a licensee in identifying an appropriate technological approach for securing wireless communications in nuclear power plant. However, this methodology does not provide guidance for addressing wireless design criteria or for addressing all the cybersecurity commitments in licensees’ cybersecurity plans (CSPs) including addressing security impact analysis that a licensee must perform before an update to a Critical Digital Asset (CDA). This methodology guides a licensee through a process of evaluating a proposed wireless implementation and drafting a plant change notification for an example use case. The example is a generic/nonproprietary version of the first test case of the methodology, which, if successfully implemented, is part of the consideration for protecting other functions’ use of wireless in a cybersecure manner.
We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with the flat wall of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the resonant frequency, which can be detected with a spectrum analyzer. Because the transducer is intended for immersion in a high temperature corrosive fluid, understanding of material degradation is crucial for estimation of transducer performance lifetime, and development of measurement interpretation algorithms. We conducted a preliminary computational investigation of relevant damage mechanisms of a stainless steel 316 cylindrical resonator in FLiBe salt. The two main damage mechanisms, creep and corrosion, were modeled using multiphysics COMSOL software. Degradation was modeled for a temperature range 500°C to 700°C. Coupling of the damage mechanisms was not considered. These models predict significant inelastic deformation at most temperatures due to creep, and qualitatively predict chromium depletion both along the liquid/solid interface and along the grain boundaries. An algorithmic approach for compensation of these degradation effects during fluid flow measurements will be developed in the future work. To validate sensor physics, we have performed proof-of-principle test of flow sensing in water. For this test, we have developed a cylindrical resonator for K-band, which was machined from brass. The cavity was excited through WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder. To increase the spectral signal visibility, we developed a signal processing method for baseline subtraction. A flow loop for proof-of-principle test of transducer performance in water was assembled. A commercial flow meter was installed in the loop for reference measurements. Cylindrical cavity was excited in the TE 011 mode with resonant frequency f ≈ 17.8GHz. Frequency shift of cavity spectral response was obtained by gradually increasing water flow rate from 0 to 60gpm. Corresponding monotonic increase of resonant frequency shift by several MHz was observed. Approximate figure of merit of sensitivity to flow rate is 100KHz/GPM. In addition, we have identified an existing liquid sodium experimental setup for demonstration of flow sensing in environment similar to that of an advanced reactor. The setup consists of a cylindrical vessel and center feed line, where transducer inserted through the lid will measure velocity of the impinging liquid jet. As a calibration experiment, we have assembled a water vessel with center feed with the same dimensions as those of the liquid sodium setup. We have also developed and insertion probe consisting of a 50cm brass waveguide enclosed in protective SS316 tube. Using the water loop, we have demonstrated feasibility of sensing the impinging liquid jet in the vessel.
Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report serves as a summary of maintenance and experimental activities during the program’s fourth year of water-based operation. A planned six-month maintenance period began in August 2021, during which major inspections, repairs, cleaning, and installation of new instrumentation and data acquisition hardware were conducted. Most significantly, two heaters that faulted during Year-3 were repaired, allowing the facility to resume use of the full heated section area and full range of available electric power. The remainder of the year consisted of eight months of test operations, during which the facility logged 211 hours of active heating across one bake-out (following the maintenance period) and seven matrix tests; five classifieds as Accepted per NQA-1, one as Trending, and one as Failed. Testing began by performing two repeat cases to confirm expected facility response and behavior during both single- and two-phase flow conditions, ensuring no changes were introduced during the maintenance period that might have altered the thermal-hydraulic characteristics of the facility. In continuation of the power parametric series initiated in previous years, a high-power test case was then performed examining heat removal performance at a decay heat load equivalent to 2.4 MWt, full-scale, a level exceeding maximum design targets. Additional testing then introduced various blockage scenarios along the network piping, examining the effects of partial and complete blockages of the flow paths on the system behavior and heat removal performance. A study of static boiling tests directed at understanding the geysering two-phase instability was also conducted. The loop was filled only to the bottom of the tank outlet, creating an open loop configuration that prevents any natural circulation flow from occurring, and the heaters were powered on until the facility reached saturation conditions. Following, a series of quasi-steady-state conditions were introduced by adjusting the inventory level in the adiabatic chimney piping at decreasingly lower elevations above the heated region. A strong correlation of geysering characteristics and loop level was observed, with flow and temperature excursions decreasing in intensity, but increasing in frequency, as the fill were reduced to lower elevations along the chimney piping. Once the level fell very low in the chimney, at points near the top of the heated section, the system reached a stable state of continuous boiling without any occurrence of geysering eruptions. A final significant testing accomplishment this year was successful completion of an “accident scenario” test, whose operating conditions were based on a prototypic decay heat curve provided by Framatome and scaled for the NSTF. This test began by establishing steady-state, single-phase “normal operation” conditions, before simulating an accident trip where the availability of active cooling systems was lost. Loop temperatures gradually increased until reaching saturation and subsequent two-phase boiling flow. Over the course of an extended operational period along the defined decay heat curve, steam boil-off caused gradual but continued depletion of liquid inventory until reaching a critically low level causing flow stagnation and cessation of natural circulation heat removal. At this point, after nearly 72 hours of continuous operation, a cold refill was performed to replenish the system inventory and allow the facility to re-establish closed loop natural circulation flow and return to a safe operational state.
I started my internship in January 2022 but the research on measuring dispersion and loss of 355nm light from a silicon oxide waveguide began in August 2022 which will be the focus of this paper. The motivation of this project is to determine whether it is possible to use pulsed 355nm light in an integrated waveguide within an ion trap chip. To begin this project, light from the 355nm Coherent Paladin laser was coupled into a fiber which will be referred to as the “source fiber.” After coupling into a fiber, loss and dispersion measurements could be performed as this fiber was used to deliver light to each of the experiments which will be covered in detail in the following paragraphs.