Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLEX”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

SO3/H2SO4 continuous real-time sensor demonstration at a power plant

We present results from field testing of a new, innovative sensor developed to measure SO3/H2SO4 continuously and in real time at a coal-fired power plant. The system utilizes the sensitivity, specificity, and real-time capabilities of mid-infrared (Mid-IR) laser-based sensor technology, along with a heated, close-coupled cell mounted directly to a power plant duct. Measurements were made by the laser sensor over a 2-day period and compared to results from the accepted method, EPA 8A, which requires a 30-minute collection, labor intensive processing, and off-site analysis at a lab. In contrast to the condensation method, the laser sensor continuously samples flue gas and reports measurements of the concentration of SO3/H2SO4, SO2 ever second with unattended operation. This initial demonstration proved the sensor concept and paves the way for its use for optimizing sorbent injection used to neutralize SO3/H2SO4. Optimized sorbent injection will enable significant cost savings associated with efforts to mitigate the presence and effects of SO3/H2SO4 such as “Blue Plume”, air heater fouling, and duct corrosion. In particular, the real-time, actionable information will enable better control of additive injection in flex conditions and variable fuels.

20 FOSSIL-FUELED POWER PLANTS↗

Flexible wave energy converter

Disclosed herein are flexible wave energy converters that actuate electrical generators with dynamic strain (e.g., flexing, stretching, twisting, distension) to convert wave energy to electrical energy. The flexible wave energy converter utilizes flexible electric generators embedded throughout the wave-energy converter's flexible body.

16 TIDAL AND WAVE POWER↗

The design and test results of A Giga-Bit Cable Receiver (GBCR) for the ATLAS Inner Tracker Pixel Detector

This paper presents the design and test results of a Gigabit Cable Receiver ASIC called GBCR for the HL-LHC upgrade of the ATLAS Inner Tracker (ITk) pixel detector. Three prototypes (GBCR1, GBCR2, and GBCR3) have been designed in the CERN-identified 65 nm CMOS technology. GBCR receives seven (GBCR2) or six (GBCR3) channels (RX) each at 1.28 Gbps from the front-end readout chip RD53B via flex cables up to 1 meter and Twinax cables up to 5 meters and sends the equalized and retimed signals to lpGBT. Both GBCR2 and GBCR3 ASICs have two transmitting channels (TX) that pre-emphasize the signals from lpGBT before sending them to RD53B through the same cables. No Single-Event Upset (SEU) is observed in any tested channels of GBCR2 in a 400 MeV proton beam. The extrapolated bit error rate for the future HL-LHC application is below 8*10^(-16), significantly below the specified BER criterion. GBCR3 is designed to improve the immunity to single-event-upset by applying the Triple Modular Redundancy (TMR) technology to all RX channels. The retimed signals from GBCR3 have less total jitter than those from GBCR2 (35 ps versus 79 ps). Each receiver channel of GBCR3 consumes 75% more power than that of GBCR2.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Risk-informed Physical Security Using Dynamic Force-on-Force Modelling Tools (ABSTRACT)

Physical security requirement of nuclear power plants (NPPs) in the US is regulated in a mainly prescriptive manner. This “one size fits all” approach may consequently overlook plant-specific characteristics which are beneficial for the inherent safety and security of the plant. Although a performance-based security measure has been promulgated in 10 CFR 73.55(r), current evaluation methods generally emphasize static and conservative assumptions on physical security uncertainties. This conservatism contributes to the overall operational and maintenance costs, which account to 70% of total operating expenditures for an NPP. This paper describes an ongoing work at the Idaho National Laboratory within the Light Water Reactor Sustainability pathway, which aims to optimize physical protection system with regards to system effectiveness and dollar costs. To achieve this goal, a risk-informed approach to physical security is proposed. This approach leverages the Event Modeling Risk Assessment using Linked Diagrams (EMRALD) tool to model facility infiltration and Force-on-Force (FoF) engagement in a dynamic manner. The dynamic FoF analysis was conducted by coupling human performance uncertainties modeled in EMRALD to existing commercial 3-dimensional FoF software, i.e. SCRIBE3D, AVERT and Simajin. Meanwhile, risk analysis was accomplished by coupling the attack outcomes to existing plant Probabilistic Risk Assessment (PRA) model with FLEX strategy. This approach reduces the conservatisms in security modeling and further acknowledges the possibility for plant operators to mitigate the attack outcomes. A sabotage attack on a hypothetical NPP facility was devised to demonstrate the proposed methodology. Dynamic FoF rules were implemented in EMRALD coupled to SCRIBE3D. This dynamic evaluation revealed an additional 21% system effectiveness in protecting the target set relative to the static modelling approach. Furthermore, the conditional core damage probability could be reduced by up to 46% by crediting operator actions in mitigating the sabotage outcomes. We evaluated the relative importance of each component of the physical security posture included in the model and assessed tradeoffs between components to identify potential opportunities for cost reduction while maintaining a specific level of system effectiveness. Results of the cost analysis will be presented in the conference. This study is expected to help NPP operators in allocating resources optimally to satisfy the security requirements.

97 MATHEMATICS AND COMPUTING↗

RF signature detection for waveguide deformation

A radio frequency (RF) based waveguide health monitoring system is disclosed. The system employs an RF transmitter for launching a probe RF waveform into a waveguide. Reflections, etc., from the interior of the waveguide of the probe RF waveform create a signature RF waveform, with a health RF receiver receiving this resultant signature RF waveform. A health processing system analyzes the signature RF waveform, and when it detects a change indicative of a deformation of the waveguide, generates a warning signal. This change may be due to bends, flexes, vibrations (or changes in vibrations), or separations of the waveguide. The system may have low frequency, high frequency, or high frequency imaging modes. The system may employ a high-power probe RF waveform, thereby enabling a wireless charging system with power RF receivers located along the length of the waveguide providing additional functionality.

Curtis, Shane Keawe↗

Heat exchanger

A heat exchanger includes a shell housing a plurality of tubes and defining an exhaust fluid flow path within a first volume enclosed by the shell. The outer surfaces of the plurality of tubes are in fluid communication with the exhaust fluid flow path. The heat exchanger includes a cap attached to a first end of the shell and defining a second volume. A header is configured to separate the first volume from the second volume, flex with thermal expansion, and define tube inlet and outlet positions. The tube inlets and outlets are in fluid communication with a source fluid flow path, and each tube is substantially U-shaped and defines a flow path of the source fluid within the exhaust fluid flow path. The heat exchanger includes at least one longitudinal flow baffle within the shell configured to reduce an amount of exhaust fluid that may bypass the tubes.

Borghese, Joseph↗

Construction of Flexible Subterranean Hydraulic Barriers in Soil and Rock

In the management of radioactive waste sites, there is sometimes a need to divert infiltration water; or contain or divert contaminated groundwater. This paper discusses several experimental techniques based on super permeating molten wax. Many of the methods are suited to form both vertical or horizontal barriers in-situ in the ground. The first method is based on thermally controlled permeation grouting between drilled holes that produces a very thick barrier in soil, rock, or even fractured rock up to 600 meters deep. The second method is a variation on jet grouting for producing a thin low cost barrier in soil. Also discussed is a technique for forming an infiltration barrier within the surface soil over an underground tank farm and a method for encapsulating a buried waste without excavation. These new methods can produce durable subterranean barriers of high integrity. These barriers are made with a special malleable wax that soaks into the soil or rock matrix. The wax is far more impermeable than clay or cement and can flex and stretch in response to soil movements. The wax contains no water and is not prone to damage from soil moisture changes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sensor Network Demonstration for In Situ Decommissioning - 13332

Florida International University's (FIU's) Applied Research Center is currently supporting the Department of Energy's (DOE) Environmental Management Office of D and D and Facility Engineering program. FIU is supporting DOE's initiative to improve safety, reduce technical risks, and limit uncertainty within D and D operations by identifying technologies suitable to meet specific facility D and D requirements, assessing the readiness of those technologies for field deployment, and conducting feasibility studies and large scale demonstrations of promising technologies. During FY11, FIU collaborated with Savannah River National Laboratory in the development of an experimental test site for the demonstration of multiple sensor systems for potential use in the in situ decommissioning process. In situ decommissioning is a process in which the above ground portion of a facility is dismantled and removed, and the underground portion is filled with a cementious material such as grout. In such a scenario, the question remains on how to effectively monitor the structural health of the grout (cracking, flexing, and sinking), as well as track possible migration of contaminants within and out of the grouted monolith. The right types of sensors can aid personnel in better understanding the conditions within the entombed structure. Without sensors embedded in and around the monolith, it will be very difficult to estimate structural integrity and contaminant transport. Yet, to fully utilize the appropriate sensors and the provided data, their performance and reliability must be evaluated outside a laboratory setting. To this end, a large scale experimental setup and demonstration was conducted at FIU. In order to evaluate a large suite of sensor systems, FIU personnel designed and purchased a pre-cast concrete open-top cube, which served as a mock-up of an in situ DOE decommissioned facility. The inside of the cube measures 10 ft x 10 ft x 8 ft. In order to ensure that the individual sensors would be immobilized during the grout pouring activities, a set of nine sensor racks were designed. The 270 sensors provided by Idaho National Laboratory (INL), Mississippi State University (MSU), University of Houston (UH), and University of South Carolina (USC) were secured to these racks based on predetermined locations. Once sensor racks were installed inside the test cube, connected and debugged, approximately 32 cubic yards of special grout material was used to entomb the sensors. MSU provided and demonstrated four types of fiber loop ring-down (FLR) sensors for detection of water, temperature, cracks, and movement of fluids. INL provided and demonstrated time differenced 3D electrical resistivity tomography (ERT), advanced tensiometers for moisture content, and thermocouples for temperature measurements. University of Houston provided smart aggregate (SA) sensors, which detect crack severity and water presence. An additional UH sensor system demonstrated was a Fiber Bragg Grating (FBG) fiber optic system measuring strain, presence of water, and temperature. USC provided a system which measured acoustic emissions during cracking, as well as temperature and pH sensors. All systems were connected to a Sensor Remote Access System (SRAS) data networking and collection system designed, developed and provided by FIU. The purpose of SRAS was to collect and allow download of the raw sensor data from all the sensor system, as well as allow upload of the processed data and any analysis reports and graphs. All this information was made available to the research teams via the Deactivation and Decommissioning Knowledge Management and Information Tool (D and D KM-IT). As a current research effort, FIU is performing an energy analysis, and transferring several sensor systems to a Photovoltaic (PV) System to continuously monitor energy consumption parameters and overall power demands. Also, One final component of this research is focusing on developing an integrated data network to capture, log and analyze sensor system data in near real time from a single interface. FIU personnel and DOE Fellows monitored the progress and condition of the sensors for a period of six months. During this time, the sensors recorded data pertaining to strain, compression, temperature, crack detection, moisture presence, fluid mobility, shock resistance, monolith movement, and electrical resistivity. In addition, FIU regularly observed the curing process of the grout and documented the cube condition via the nine racks of sensors. The sensors held up throughout the curing process, withstood the natural elements for six months, and monitored the integrity of the grout. The large scale experiment and demonstration conducted at FIU was the first of its kind to demonstrate the feasibility of state of the art sensors for in situ decommissioning applications. These efforts successfully measured the durability, performance, and precision of the sensors in question as well as monitored and recorded the curing process of the selected grout material under natural environmental conditions. The current energy analysis work is resulting in data on the constraints placed by some of the sensor systems on a power network that requires high reliability and low losses. In addition, a sensor system demonstration has determined that it is feasible to develop an integrated data network where data can be accessed in near real-time from all systems, thereby allowing for larger-scale integrated system testing to be performed. Information collected during the execution of this research project will aid decision makers in the identification of sensors to be used in nuclear facilities selected for in situ decommissioning. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Compact pulse transformer for 85 kV, 3.5 μs electron gun anode of compact X-ray cargo scanner

Design of compact and reliable 85kV HV pulse transformer for electron gun anode pulsing is a major concern, when size and space are constraints. This paper describes design procedures and optimization of various parameters like HV insulation, step up ratio, rise time and flat top of Pulse transformer, operating with input from a 10 stage PFN of 50 ohm impedance and charged at 14kV. The transformer should deliver rated output voltage of negative polarity 85kV, 3 to 4μs pulse width, less than 2μs rise time and flat top within 10% across an electron gun load, equivalent to a parallel combination of 10kΩ and 200pF load at a PRF of 250 Hz. Since the Cargo Scanner has to operate on movable carrier, this transformer is designed to operate even in the inclined positions. This transformer has given voltage step up, rise time and flat top of 13.75, 1.5 μs and 4.5% respectively for a 10kΩ and 200pF load at 250Hz PRF and also demonstrated operation in 90{sup °} tilted transformer positions. An effort has been put to achieve maintenance free Pulse transformer by providing effective sealing in the transformer tank to stop breathing action. Also, special flexing walls of transformer tank accommodate for small changes in volume of oil due to temperature variations. (author)

43 PARTICLE ACCELERATORS↗

Flexible wave energy converter

Disclosed herein are flexible wave energy converters that actuate electrical generators with dynamic strain (e.g., flexing, stretching, twisting, distension) to convert wave energy to electrical energy. The flexible wave energy converter utilizes flexible electric generators embedded throughout the wave-energy converter's flexible body.

30 DIRECT ENERGY CONVERSION↗

Moving Beyond Traditional Tornado Missile Impact Analysis

On March 11, 2011 a 9.0 magnitude earthquake occurred off the coast of Japan creating a tsunami, which together severely damaged northeastern Japan including the Fukushima Dai-ichi nuclear power plant site. In response to this event, the United States (U.S.) Nuclear Regulatory Commission (NRC) issued Order EA-12-049, 'Issuance of Order to Modify Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events'. In order to meet the guidance of the NRC Order EA-12- 049, the a central U.S. nuclear generating station (Plant) was required to demonstrate that the currently installed Borated Water Storage Tank (BWST), Refueling Water Tank (RWT), and Qualified Condensate Storage Tank (QCST) could provide the necessary capacity following a Beyond Design Basis External Event (BDBEE). These tanks were not originally designed to meet current site design basis requirements for tornado wind and missile impacts. To save the Plant from having to build costly new storage tanks off site, the existing tanks were credited as robust for tornado missile impact through advanced finite element impact analyses using the ANSYS Autodyn solver and fluid-structure interaction (FSI). This procedure is the first known NRC acceptance of advanced analysis and FSI for to satisfy the FLEX tornado missile impact criteria. Extensive verification and validation (V and V) was performed to verify perforation of steel plates which included FSI. These V and V analyses were confirmed against large databases of experimental and theoretical results to ensure accurate modeling and results. The use of this advanced analytical method benefitted the Plant in several ways. A new storage tank was not required to be built, saving not only initial construction costs but also ongoing maintenance costs and monitoring activities. By determining specific vulnerable components of each tank a set of modifications and protection schemes were developed. These modifications were much quicker to implement saving the Plant on downtime costs. (authors)

42 ENGINEERING↗

Characterizing The Mechanical Properties of Polyurethane Foams

The Department of Energy has many radioactive facilities that are on the path of deactivation and decommissioning (D and D). These facilities can sit cold and dark for many years before final disposition, and must be maintained to ensure no radiological release occurs in the interim. Improvements and additions to D and D tool sets can greatly: Save time and money, Reduce worker risk. Conventional fixatives widely used often take the form of paints or films that are not readily applicable to 3-dimensional void spaces. Foams are one promising platform that may offer solutions to a number of contaminated problem sets such as: Gloveboxes, Pipes, Tanks. SRNL is working to characterize various commercial foams that would encapsulate the interior volume of a given space and are capable of immobilizing any remaining contamination. One key performance metric of these foams is how well they will perform in an accident scenario. To this end, SRNL is researching the mechanical properties of these foams to ensure that the material can withstand the environment of application while maintaining structural integrity. ASTM standard E3191-18 served as a guiding document for this project, outlining the requirements that foaming fixatives used for the mitigation of radioactive contamination need to meet before being implemented. Objective: Quantification of the mechanical properties of 6 commercial polyurethane foams was performed using multiple ASTM standards to record measurements for: Compression testing: Flexible Foams, Force required to produce 50% compression, Rigid Foams, Compressive and apparent modulus, Point of 10% core deformation, The 'Zero Deformation' point, Compressive strength, Yield point. Tensile testing: Tensile strength, Tensile stress, Percent elongation. Experiment 1: An electromechanical compressive tester (MTS Criterion Series 43) was used to evaluate 6 foams (4 flexible, 2 rigid). Per ASTM D1621, each rigid foam was compressed at 10% of the measured thickness per minute until the sample was 13% of it's original thickness. Per ASTM D35/4, each flexible foam was pre-flexed twice to 80% original thickness at a rate of 250 mm/min, then compressed to 80% original thickness at a rate of 50 mm/min. Experiment 2: An electromechanical tensile tester (MTS Criterion Series 43) was used to evaluate 6 foams (4 flexible, 2 rigid). Per ASTM D1623, rigid foams were pulled apart at a rate of 1.27 mm/min until the sample broke. Per ASTM D35/4, flexible foams were pulled apart at a rate of 500 mm/min until the sample broke. The strongest material in both compression and tensile testing scenarios was found to be the rigid intumescent polyurethane Hilti foam. The experiments revealed that the Hilti foam in a tensile scenario had a peak stress value that was larger than the closest competitor by a factor of 2.3 and a compressive yield point that was larger than the closest competitor by a factor of 1.4, indicating that the Hilti foam is the best choice for implementation in mechanically harsh environments. The performance metrics measured can serve as a basis for future mechanical tests that would help set relevant ASTM standards (E3191) for intumescent polyurethane foams in fixating applications. Tests like surface adhesion, impact, and flame tests would serve as a better indicator as to how this material would perform in environmentally harsh scenarios often found in decommissioned nuclear facilities. Further tests of the foams' intumescent properties would also be important should these foams be implemented in environmentally harsh scenarios.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Packaging a 650V/400A GaN Half-bridge Power Module with Ultra-low Parasitics for Electric Vehicle Drive Applications

This paper proposes a compact and efficient half-bridge power module with three 650 V / 150 A GaN dies in parallel. The power module incorporates a main power printed circuit board (PCB), an interface PCB, and a flex PCB to achieve low parasitics in both power loop and gate-side connection, resolving the issue of high parasitics typically encountered with wire bonding in high-current applications. Additionally, the interface PCB decouples the design constraints between the power loop and the gate loops. The proposed design is optimized with a vertical loop configuration to reduce power loop inductance through magnetic flux cancellation. Finite element analysis indicates that the power loop inductance is 0.58 nH at 100 MHz, while the maximum die junction temperature reaches 131 °C under an ambient temperature of 65 °C and a load current of 385 A. The proposed multi-piece PCB structure reduces the inductance of the drive circuit to minimize EMI and to mitigate false triggering. At the same time, it reduces impedance mismatches across different driver circuits, thereby achieving dynamic current sharing in multi-chip parallel configurations. Under simulation conditions of 400 V / 385 A, the current imbalance among chips was limited to 5 A. A 400 V / 385 A double-pulse test was conducted to experimentally validate the performance of the proposed power module.

30 DIRECT ENERGY CONVERSION↗

Rewarding Grid-Friendly Behavior: Estimating the Potential Bill Reduction and Load Shifting Benefits of Dynamic Prices

Shifting electric load from times of peak demand can be a key strategy to slow price growth as reducing peak demand avoids the cost of upgrading generation, transmission and distribution infrastructure. Utilities are releasing time-varying prices, such as time of use rates or dynamic prices, to incentivize grid-friendly load shifting. New dynamic price programs provide insight into the true cost of operating electricity grids and the potential economic benefits of load shifting. Program developers and device manufacturers need to understand the economic opportunities in terms of 1) the variation in prices across hours, days, and seasons; 2) the change in utility bills for customers who don’t shift load; and 3) the potential load shifted and economic value of different technologies if manufacturers or aggregators deploy price-responsive controls. This paper estimates possible impacts of dynamic price adoption and load shifting controls if customers paid the dynamic rate from one pilot program. Statistical analysis of historical prices identified annual and seasonal metrics as well as representative price curves for each circuit in the pilot. Simulations for residential technologies with price-responsive controls including unitary heat pump water heaters, central multifamily heat pump water heaters, heating & cooling + storage systems, and pool pumps estimated the potential impacts of highly dynamic prices both with and without load shifting controls. Results showed the potential to reduce electricity costs on representative days by 42-94% and reduce consumption during times of high electricity prices by 63-100% compared to baseline operation for those flex-friendly devices.

Grant, Peter↗

A Model of an Electrical Discharge in the Flance Contacts With Omega Seals at High Currents in PEP-II

During PEP-II operation with high currents in the High Energy Ring (HER), elevated temperatures were found at many locations in the vacuum chamber where they have an RF seal for the flex flange. Most of these omega RF seals were badly damaged and had evidence of metal vaporization from sparks and electrical discharge. They suggest a physical model, which may explain this effect.

43 PARTICLE ACCELERATORS↗

High-Current Effects in The PEP-II Storage Rings

High beam currents in PEP-II have been a challenge for vacuum system and ring components. For the {approx} 1 cm long bunches peak currents exceed 100 A and modest impedance can give rise to voltage spikes and discharges. During the last two runs, difficulties arose from rf seals at the 'flex flanges' in the HER. High temperatures were seen and the seals turned out to be severely damaged by discharges. In the LER, the horizontal stripline kickers of the bunch-by-bunch feedback system experiences breakdown at high bunch current-Macor pins installed for mechanical stability turned out to be a weak spot causing discharges. Finally, in the HER an experiment to shorten the ion-clearing gap in the beam revealed signs of ion-induced instability indicating that the HER has been operating quite close to the stability limit. The effects shown here are relevant to future high-intensity electron and positron rings like SuperB and PEP-X.

43 PARTICLE ACCELERATORS↗

Simultaneous multi-headed imager geometry calibration method

A method for calibrating multi-headed high sensitivity and high spatial resolution dynamic imaging systems, especially those useful in the acquisition of tomographic images of small animals. The method of the present invention comprises: simultaneously calibrating two or more detectors to the same coordinate system; and functionally correcting for unwanted detector movement due to gantry flexing.

47 OTHER INSTRUMENTATION↗

Hydrothermal Barium Titanate Thin-Film Characteristics and their Suitability as Decoupling Capacitors

System integration and miniaturization demands are driving integrated thin film capacitor technologies towards ultrahigh capacitance densities for noise-free power supply, power conversion and efficient power management. Hydrothermal route can deposit crystalline ferroelectric films at low temperatures of less than 150 C. It is hence an attractive route for integrating high permittivity thin film capacitors on organic, silicon or flex substrates. However, hydrothermal films are not commercialized so far because of their inferior insulation characteristics. Embedded hydroxyl groups are attributed to be the cause for high leakage currents, temperature dependent properties and lower Breakdown Voltages (BDVs). This paper discusses the dielectric characteristics such as capacitance density, leakage currents and Temperature Coefficient of Capacitance (TCC) of hydrothermal barium titanate films and correlates them to the embedded water and OH groups, film morphology, stoichiometry and crystallinity. With thermal treatment, majority of the OH groups can be removed leading to improved insulation characteristics. The room temperature I-V characteristics agreed with ionic conduction models for films baked at 160 C while higher baking temperatures of above 300 C resulted in Poole-Frenkel type conduction. A brief perspective is provided on the suitability of hydrothermal thin film capacitors for power supply applications.

36 MATERIALS SCIENCE↗