Search NASA⌕ Search

SEARCH · Search NASA

Results for “FOULING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Filtration device for rapid separation of biological particles from complex matrices

Methods and systems for filtering of biological particles are disclosed. Filtering membranes separate adjacent chambers. Through osmotic or electrokinetic processes, flow of particles is carried out through the filtering membranes. Cells, viruses and cell waste can be filtered depending on the size of the pores of the membrane. A polymer brush can be applied to a surface of the membrane to enhance filtering and prevent fouling.

47 OTHER INSTRUMENTATION↗

LiF dissolution by anion-binding-agent in LiCF x battery systems: Lower ohmic and interfacial resistance.

In this paper we will discuss our preliminary thermal and electrochemical data aimed at developing a robust nonflammable Li-CFx cell capable of wide temperature operation. To accomplish this goal, we are evaluating a thermally stable solvent comprised of an anion binding agent (ABA) and lithium fluoride (LiF), typically at a 1:1 molar ratio. In conventional carbonate based electrolytes, ABA is soluble while LiF remains insoluble. However, the neutral ABA solubilizes LiF and forms a salt complex represented as Li+(ABAF-). We are exploiting this unique feature and apply this strategy to CFx chemistry to improve cell performance, due to the CFx cell chemistry generating LiF as discharge product. Continuous solvation of the salt mixture during discharge allows for utilization of electrolytes initially containing sub stoichiometric amount of LiF. The practical benefits are reduced cell weight, mitigation of electrode fouling, and consequently better low temperature performance. Electrolytes containing dimethyl methyl phosphonate (DMMP), 1M tris(pentafluorophenyl) borane (TPFB) and varying concentrations of LiF (1M; 0.5M and 0.1M) were prepared and characterized for ionic conductivity and voltage stability. In general, ionic conductivity decreases with decreasing LiF concentration. The room temperature conductivity for the DMMP 1M TPFB:1M LiF is ~ 9mS/cm and ~3mS/cm for the 1M TPFB:0.1M LiF. Unlike the conductivity, the electrochemical voltage stability did not vary substantially with LiF concentration and the electrolytes showed a stable voltage window in the range 0-3.5V vs. Li + /Li, which is substantially wider than the Li-CFx cell voltage. Flammability measurement performed at our thermal abuse facility demonstrated that the electrolyte was nonflammable. Discharge performance of CFx materials obtained from several vendors was evaluated in 2032 coin cells at room temperature. Experimental results demonstrate a reduction in ohmic resistance and interfacial resistance during discharge for a cell containing lower concentrations of added LiF compared to ABA. These observations are a direct demonstration that the unbound ABA in the electrolyte dissolves the LiF generated in the discharge reaction.

25 ENERGY STORAGE↗

Slippery self-lubricating polymer surfaces

The present disclosure describes a strategy to create self-healing, slippery self-lubricating polymers. Lubricating liquids with affinities to polymers can be utilized to get absorbed within the polymer and form a lubricant layer (of the lubricating liquid) on the polymer. The lubricant layer can repel a wide range of materials, including simple and complex fluids (water, hydrocarbons, crude oil and bodily fluids), restore liquid-repellency after physical damage, and resist ice, microorganisms and insects adhesion. Some exemplary applications where self-lubricating polymers will be useful include energy-efficient, friction-reduction fluid handling and transportation, medical devices, anti-icing, optical sensing, and as self-cleaning, and anti-fouling materials operating in extreme environments.

36 MATERIALS SCIENCE↗

Common Faults and Their Prioritization in Small Commercial Buildings

This study documents faults that are commonly found in small commercial buildings based on a literature review and discussions with building commissioning experts. It also provides a list of prioritized faults based on an estimation of the prevalence, energy impact, and financial impact of each fault. A total of 39 faults were analyzed for this paper and classified by location, stage, and type. The technical complexity of detecting each type of fault based on typically available information was evaluated for each fault. The annual energy impact (AEI) and annual financial impact (AFI) of each fault were estimated based on available information. Based on these estimates, 20 top priority faults were identified. Seven out of the 20 top priority faults occur in vapor compression systems such as air-conditioning, heat pump, and refrigeration equipment. Nonstandard charging, condenser, and evaporator fouling are the most important faults for this type of equipment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SUBTASK 2.3 – SUPPORT OF DOE CARBON CAPTURE SYSTEMS DEVELOPMENT AND MODELING

The ultimate goal of this project is to reduce uncertainty in the deployment of carbon capture and storage (CCS) technologies by overcoming key challenges through a combination of experimentation and modeling studies. The studies focused on key areas of concern for CCS systems and worked to increase overall confidence in the technology. To achieve project goals, the Energy & Environmental Research Center (EERC) identified the following objectives: Determine the potential impacts of coal combustion-derived aerosols on solvent emissions, solvent degradation, and fouling of postcombustion CO2 capture systems. Identify methods to control the formation of aerosols. Evaluate, quantify, and document the regional impacts that could result from implementation of CO2 capture technologies and enhanced oil recovery. Support U.S. Department of Energy (DOE) modeling efforts by providing key information to help reduce the uncertainty of future CCS projects and increase investor and public confidence in the technologies. Four activities were executed to support this effort, and the detailed results of these activities are presented herein. This project was cofunded through the EERC–DOE Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission, Mitsubishi Heavy Industries America, Minnkota Power Cooperative, ALLETE, and the Lignite Energy Council.

01 COAL, LIGNITE, AND PEAT↗

Multi-stage circulating fluidized bed syngas cooling

A method and apparatus for cooling hot gas streams in the temperature range 800° C. to 1600° C. using multi-stage circulating fluid bed (CFB) coolers is disclosed. The invention relates to cooling the hot syngas from coal gasifiers in which the hot syngas entrains substances that foul, erode and corrode heat transfer surfaces upon contact in conventional coolers. The hot syngas is cooled by extracting and indirectly transferring heat to heat transfer surfaces with circulating inert solid particles in CFB syngas coolers. The CFB syngas coolers are staged to facilitate generation of steam at multiple conditions and hot boiler feed water that are necessary for power generation in an IGCC process. The multi-stage syngas cooler can include internally circulating fluid bed coolers, externally circulating fluid bed coolers and hybrid coolers that incorporate features of both internally and externally circulating fluid bed coolers.

Liu, Guohai↗

Fluid-based gating mechanism with tunable multiphase selectivity and antifouling behavior

A gating mechanism that uses a capillary stabilized liquid as a reversible, reconfigurable gate that fills and seals pores in the closed state, and creates a non-fouling, liquid-lined pore in the open state is disclosed. Theoretical modeling and experiments demonstrate that for each transport substance, the gating threshold—the pressure needed to open the pores—can be rationally tuned over a wide pressure range. This enables realizing in one system differential response profiles for a variety of liquids and gases, even letting liquids flow through the pore while preventing gas from escaping. These capabilities allow dynamic modulation of gas-liquid sorting and to separate multi-phase mixtures, with the liquid lining ensuring sustained antifouling behavior. Because the liquid gating strategy enables efficient short-term and long-term operation and can be applied to a variety of pore structures and membrane materials, and to nano, micro as well as macroscale fluid systems, the gating systems is useful in a wide range of applications.

36 MATERIALS SCIENCE↗

Atomic Layer Deposition (ALD) to Extend Catalyst Lifetime for Biobased Adipic Acid Production

Robust heterogeneous catalysts are essential for enabling biomass conversion; however, harsh reaction environments introduce durability challenges for many conventional catalyst materials [1]. The hydrogenation of biobased muconic acid to adipic acid is one such emerging chemistry that faces PGM catalyst stability challenges [2]. Muconic acid is a heavily-investigated biobased platform chemical that can be converted into an array of large-market commodity chemicals [2]. PGM catalysts are exceptionally effective for muconic acid hydrogenation to adipic acid, with Pd the most active to date. [2] However, Pd leaches in an acidic environment and this chemistry has a high propensity for fouling. Atomic layer deposition (ALD) is one such material design strategy that has emerged to stabilize supported metal catalysts [3]. ALD coatings are theorized to stabilize supported metal active sites by i) covering high-energy facets most susceptible to degradation, ii) disrupting the physical mobility of active sites, and iii) reinforcing the structure of the underlying catalyst support [3]. However, ALD coatings for catalyst durability with carboxylic acids remains an underdeveloped area of research and literature reports have yet to consider the techno-economic tradeoffs between the ALD manufacturing cost and catalyst lifetime productivity. This study examines low-cycle Al2O3 ALD coatings to stabilize Pd/TiO2 against deactivation during muconic acid hydrogenation. The unique harshness of muconic acid for Pd leaching was evaluated by both experiment and computation. Based on batch reactor screening results, uncoated and ALD coated catalysts were evaluated in a continuous flow reactor for their productivity, stability, and post-reaction regenerability at 700 degrees C. Characterization was performed to assess the impact of ALD coatings on catalyst morphology, as well as following regeneration. Finally, techno-economic analysis models evaluated the value proposition for ALD-coated catalysts within an nth-generation adipic acid biorefinery.

09 BIOMASS FUELS↗

Hydrophilic, light active coating for membranes

A porous membrane provides enhanced filtration of pollutants and particles by coating the membrane with conformal thin films of doped titanium dioxide via atomic layer deposition or, alternatively, sequential infiltration synthesis. The membrane can either be organic or inorganic, and the doping of the membrane, usually with nitrogen, is an important feature that shifts the optical absorption of the TiO2 from the UV range into the visible-light range. This enables the use of lower energy light, including sunlight, to activate the photocatalytic function of the film. The coating described in the present invention is compatible with virtually any porous membrane and allows for precise tuning of the pore size with molecular precision. The present invention presents a new coating process and chemical structure that provides catalytic activity, strongly enhanced by light, to both mitigate fouling and break down various organic pollutants in the process stream.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Railroad block/grade crossing warning system

A train safety system comprises a cable connected to at least two conducting contacts, an electrical load between said two conducting magnetic contacts, and a DC track circuit associated with railroad tracks wherein the at least two conducting plates can be connected to each of the railroad rails in order to shunt the DC track circuit and alert oncoming trains of fouling of the tracks or crossing ahead.

42 ENGINEERING↗

A Numerical Study on the Energy Performance of a Novel Furnace With Acidic Gas Trap Absorbers

Natural gas furnaces are widely used in US residential and commercial building markets. An important issue for natural gas furnaces is serious corrosion and fouling problems caused by acidic gas, such as SOx. An advanced adsorption technology based on acidic gas trap (AGT) absorbers offers the possibility to remove SOx acidic gas from natural gas furnaces with high efficiency and low cost, thereby enabling the development of condensing furnaces without the use of expensive corrosion resistant materials in the heat exchanger. A three-dimensional (3D) computational fluid dynamics (CFD) model has been developed to evaluate the heat transfer performance of a furnace with AGT absorbers and to compare it with a baseline conventional furnace without the AGT. Moreover, an axisymmetric model has been built focusing on the absorbing process in the AGT. The baseline conventional furnace used for the study is a commercial condensing furnace (Rheem 92% AFUE 84,000 BTU Multi-Position Gas Furnace). This furnace was completely disassembled, and the dimensions of each part were carefully measured and used to build a detailed CFD model. A model representing the new furnace, incorporating the AGT absorbers, was developed by adding the AGT system to the conventional furnace model. For the CFD analysis, a mixture model was employed to characterize the heat and mass transfer during the condensing process in the furnace while considering three components—air, water vapor and liquid water. Condensation takes place in the condensing heat exchanger, where water vapor changes phase to liquid water, and the latent heat is thus used in the furnace for useful heating. The simulation results characterize the energy performance of both the conventional furnace and the novel furnace with AGT absorbers, as well as the reactive processing in the AGT. These results provide insightful guidance for the development of the AGT absorber-based furnace from the perspective of its energy performance and will be used to further optimize this novel furnace design.

Laclair, Tim↗

System with a direct contact desublimating heat exchanger and temperature regulation

A process to prevent fouling using a desublimating heat exchanger is disclosed. An outlet stream from the desublimating heat exchanger may be split into a plurality of parallel streams. The parallel streams may be sent through a plurality of discrete unit operations, and the unit operations may change the temperature of at least one of the parallel streams. Parallel streams of differing temperature may emerge from the unit operations. The parallel streams which are of a similar temperature may be mixed to form a warm stream and a cool stream. The warm stream and the cool stream may be sent to a mixing chamber. A mixed stream of substantially uniform temperature may emerge from the mixing chamber, and the mixed stream may be recycled back to the desublimating heat exchanger. The mixing chamber may be separate from the desublimating heat exchanger, or the parallel streams of differing temperature may be mixed in the desublimating heat exchanger.

42 ENGINEERING↗

Process for generating high purity synthesis gas hydrogen from heavy oil or hydrocarbons

The present invention provides a steam reforming process for heavy oil or hydrocarbons using a circulating fluidized bed reactor, the process having a reforming step and a regeneration step, wherein the reforming step and the regeneration step comprise a fluidized reactor containing a fluidizable nickel-containing reforming catalyst and produce hydrogen as a product of the reforming bed. The invention produces high purity hydrogen in the synthesis gas product stream and avoids irreversible fouling on the catalyst.

Srinivas, Girish↗

Clean and High-Efficiency Natural Gas Furnace with Advanced Acidic Gas Trap Technology

Ccurrent natural gas condensing furnaces generate substantial acidic condensate and SOx/NOx/CO/HC/methane emissions, causing long-term environment issues related to air, water and soil. Acidic condensate occurs when flue gases within the furnaces cool down below the dew points of acidic gases, which upon condensation, combine with water vapor to produce acidic solutions. The acidic condensate causes serious corrosion and fouling problems in natural gas condensing furnaces. This paper presents a novel solution to use an advanced adsorption technology based on monolithic acidic gas trap (AGT) adsorbers for SOx trapping, NOx redox, and formic acid/CO/HC/methane oxidation, enabling a new natural gas furnace with utra-clean flue gas and neutral condensate. When the AGT adsorber is appropriately integrated with natural gas furnaces, the acidic gases of SOx, NOx and formic gas/CO/HC will be continuously adsorbed, redoxed or oxidized, respectively, from the flue gas during a regular heating season, except for occasional regeneration activities for SOx trapping. In the paper, we present results from a prototype furnace employing the novel AGT component, which enables a pH of the condensate =7, NOx emissions of 1-2 nanograms/joule and an annual fuel utilization efficiency (AFUE) of 96%, providing a cost-effective technology for condensing furnaces that is eco-friendly to the environment.

Gao, Zhiming↗

Methods, apparatus and systems for generating and superheating vapor under sunlight

A solar vapor generator includes an absorber to absorb sunlight and an emitter, in thermal communication with the absorber, to radiatively evaporate a liquid under less than 1 sun illumination and without pressurization. The emitter is physically separated from the liquid, substantially reducing fouling of the emitter. The absorber and the emitter may also be heated to temperatures higher than the boiling point of the liquid and may thus may be used to further superheat the vapor. Solar vapor generation can provide the basis for many sustainable desalination, sanitization, and process heating technologies.

Chen, Gang↗

Topical Report – Findings on Subtask 2.7 – Wet ESP and Aerosol Testing at Coal Creek Station

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion carbon capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery. The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the unique components present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants by contributing to aerosol formation. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and flue gas particulate provides nucleation sites where amine vapors can condense as aerosols. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, particulate components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to fully characterize aerosol behavior with various control technologies installed to better optimize aerosol mitigation technology for CO 2 capture. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on mitigating formation of problematic aerosols at Great River Energy’s Coal Creek Station, upstream of the PCCC system. Determine the effectiveness of the Mitsubishi Heavy Industries (MHI) proprietary amine emission reduction unit (AERU) as a postcapture solvent recovery system for reducing aerosol emissions and extending solvent life downstream of the PCCC system. Determine the impact of aerosols on the efficiency and degradation products of both commercial and advanced solvents within the PCCC system. Work was conducted at Coal Creek Station Unit 1 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then optionally routed through a WESP before passing to the CO 2 absorber columns. The MHI solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . Flue gas exiting the absorber column was routed to MHI’s proprietary AERU to recover entrained solvent. The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Particulate was measured, collected, and analyzed from multiple locations throughout the pilot-scale system. Unlike the performance observed in prior work, the inlet FGD and DCC did not remove significant particulate matter from the flue gas. This appears to be due to a difference in the nature of the particulate. The DCC seemed to increase particulate size and count, most likely owing to water condensing onto the surfaces of fly ash particles. When the WESP was operated, it achieved >95% particulate capture. Very little particulate matter or indications of solvent were detected at the AERU outlet. When operating with advanced KS 21 solvent, the particulate material at the AERU outlet was even further decreased. Solvent analysis showed that some species derived from flue gas and ash were slowly concentrating in the solvent over the duration of the test. The levels observed were reported to be within expected ranges and were not of concern to MHI. A high-level techno-economic assessment of installing CO 2 capture at Coal Creek Station suggested that, when using a standard monoethanolamine (MEA)-based solution with simple heat integration, the energy penalty to net generation would be 34%. The bulk of this was due to steam losses for regenerating solvent, followed by parasitic electrical demand for CO 2 compression and then by increased parasitic load for pushing flue gas through the absorber column. These demands could be decreased with a more advanced solvent that exhibits lower heat of regeneration and lower pressure drop than does a simple MEA solution. Further energy could be saved with more thorough heat integration to recover useful energy from the steam used for solvent regeneration. Installing a WESP was predicted to increase the cost of electricity by nearly $5/MWh. This would become cost-effective if solvent losses were roughly 10 times the baseline estimate when not using a WESP but could be returned to baseline by installing the WESP. Piping CO 2 for storage in more favorable geology could help with carbon capture and storage economics. Although storing off-site would necessitate construction of a CO 2 transport pipeline, the cost of this pipeline might be more than offset by reducing the number of wells required, the depths of the wells required, and the electrical demand for the CO 2 compressor. Additional factors that favor off-site storage costs include smaller expected CO 2 plume sizes, which translates to less monitoring and fewer landowner agreements. More detailed assessment of the specific geology in the region under and around Coal Creek Station would be needed to accurately assess the costs and benefits of different storage site options. This subtask was cofunded through the Energy & Environmental Research Center–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission.

Strege, Joshua↗

SO3/H2SO4 continuous real-time sensor demonstration at a power plant

We present results from field testing of a new, innovative sensor developed to measure SO3/H2SO4 continuously and in real time at a coal-fired power plant. The system utilizes the sensitivity, specificity, and real-time capabilities of mid-infrared (Mid-IR) laser-based sensor technology, along with a heated, close-coupled cell mounted directly to a power plant duct. Measurements were made by the laser sensor over a 2-day period and compared to results from the accepted method, EPA 8A, which requires a 30-minute collection, labor intensive processing, and off-site analysis at a lab. In contrast to the condensation method, the laser sensor continuously samples flue gas and reports measurements of the concentration of SO3/H2SO4, SO2 ever second with unattended operation. This initial demonstration proved the sensor concept and paves the way for its use for optimizing sorbent injection used to neutralize SO3/H2SO4. Optimized sorbent injection will enable significant cost savings associated with efforts to mitigate the presence and effects of SO3/H2SO4 such as “Blue Plume”, air heater fouling, and duct corrosion. In particular, the real-time, actionable information will enable better control of additive injection in flex conditions and variable fuels.

20 FOSSIL-FUELED POWER PLANTS↗