Fabrication of the Fermilab Pre-Series Cold Mass for the HL-LHC Accelerator Upgrade Project

Fermilab is fabricating ten full length cold masses for the high-luminosity Large Hadron Collider Accelerator Upgrade Project (HL-LHC AUP). One practice assembly and one pre-series assembly have been completed. Here this paper summarizes the construction details. Topics include incoming inspection, bus assembly, component machining, shell forming, beam tube insertion, bus expansion loop installation, instrumentation installation, electrical testing, heat exchanger installation and final assembly welding. In-process surveys, alignment measurements and testing are presented and explained. Problems encountered during construction and their solutions are discussed.

43 PARTICLE ACCELERATORS↗

Development of a Bi2212 Dipole Insert at Fermilab

A goal of the U.S. Magnet Development Program (US-MDP) is high-field magnets for accelerators with magnetic fields larger than 15 T, i.e., above the limits of Nb 3 Sn accelerator magnets. Composite round wires and Rutherford cables made of high temperature superconductor Bi2212 may achieve this goal. Bi2212 is sensitive to transverse stresses and strains, and this requires stress management in the coil design. A stress management approach was developed at Fermilab for high-field large-aperture Nb 3 Sn accelerator magnets. Now it is being applied to high-field dipole insert coils based on Bi2212 Rutherford cable. Here this paper describes the insert coil design and main parameters, including the superconducting wire and cable. The coil will be installed inside a 60-mm bore Nb 3 Sn dipole outsert coil and cold iron yoke. The Bi2212 coil will be tested individually and in series with the Nb 3 Sn outsert coil. The expected Bi2212 insert test parameters are reported and discussed.

43 PARTICLE ACCELERATORS↗

ORBUMP Pulsed Dipole Magnet Design for Fermilab Booster

Fermilab initiated the accelerator magnet system upgrade project PIP-II for future neutrino experiments. Old ORBUMP pulsed dipoles should be replaced with new stronger magnets occupying the same space as old ones. Four of these magnets connected in series form dogleg type of proton beam orbit. The magnet field and 19 kA current pulse length are close to 1 ms. Old magnet cores were based on a ferrite material. For new magnets, a magnet gap field is above 0.4 T, which completely saturates ferrite material. So, for the magnet core, 0.127 mm thick laminations of low carbon steel with inorganic coating, as the magnet were placed in a vacuum box. There were investigated transient magnet parameters including skin effect in the iron core and in the single-turn copper coil. The integrated field homogeneity was improved by the copper coil shimming. Simulated by OPERA3D power losses were used for the thermal analysis by ANSYS code. The magnet performance is strongly coupled with the power source. The dynamic magnet inductance and resistance were included in the pulsed power source design. Finally, the paper presented the ORBUMP magnet system design.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Status of the Top Plate and Anticryostat for High Field Cable Test Facility at Fermilab

Fermi National Accelerator Laboratory (Fermilab) is currently constructing a new High Field Vertical Magnet Test Facility (HFVMTF) designed for testing High Temperature Superconducting (HTS) cables under high magnetic fields. This facility is expected to offer capabilities similar to those of EDIPO at PSI and FRESCA2 at CERN. The background magnetic field of 15 T will be generated by a magnet supplied by Lawrence Berkeley National Laboratory. The primary function of HFVMTF will be to serve as a superconducting cable test facility, facilitating tests under high magnetic fields and a broad spectrum of cryogenic temperatures. Additionally, the facility will be utilized for testing high-field superconducting magnet models and demonstrators, including hybrid magnets, developed by the US Magnet Development Program (MDP). This paper provides a comprehensive description of the current status of two pivotal components of the facility: the Top/Lambda Plates Assembly and the Anticryostat for the Test Sample Holder. The latter will serve as a principal interface component connecting cable test samples with the facility's cryostat.

43 PARTICLE ACCELERATORS↗

Beam tests of beampipe coatings for electron cloud mitigation in Fermilab Main Injector

Electron cloud beam instabilities are an important consideration in virtually all high-energy particle accelerators and could pose a formidable challenge to forthcoming high-intensity accelerator upgrades. Dedicated tests have shown beampipe coatings dramatically reduce the density of electron cloud in particle accelerators. In this work, we evaluate the performance of titanium nitride, amorphous carbon, and diamond-like carbon as beampipe coatings for the mitigation of electron cloud in the Fermilab Main Injector. Altogether our tests represent 2700 ampere-hours of proton operation spanning five years. Three electron cloud detectors, retarding field analyzers, are installed in a straight section and allow a direct comparison between the electron flux in the coated and uncoated stainless steel beampipe. We characterize the electron flux as a function of intensity up to a maximum of 50 trillion protons per cycle. Each beampipe material conditions in response to electron bombardment from the electron cloud and we track the changes in these materials as a function of time and the number of absorbed electrons. Contamination from an unexpected vacuum leak revealed a potential vulnerability in the amorphous carbon beampipe coating. We measure the energy spectrum of electrons incident on the stainless steel, titanium nitride and amorphous carbon beampipes. We find the electron cloud signal is highly sensitive to stray magnetic fields and bunch-length over the Main Injector ramp cycle. In conclusion, we conduct a complete survey of the stray magnetic fields at the test station and compare the electron cloud signal to that in a field-free region.

43 PARTICLE ACCELERATORS↗

Semileptonic form factors for $$B\rightarrow D^*\ell \nu $$ at nonzero recoil from $$2+1$$-flavor lattice QCD: Fermilab Lattice and MILC Collaborations

Abstract We present the first unquenched lattice-QCD calculation of the form factors for the decay $$B\rightarrow D^*\ell \nu $$ B → D ∗ ℓ ν at nonzero recoil. Our analysis includes 15 MILC ensembles with $$N_f=2+1$$ N f = 2 + 1 flavors of asqtad sea quarks, with a strange quark mass close to its physical mass. The lattice spacings range from $$a\approx 0.15$$ a ≈ 0.15 fm down to 0.045 fm, while the ratio between the light- and the strange-quark masses ranges from 0.05 to 0.4. The valence b and c quarks are treated using the Wilson-clover action with the Fermilab interpretation, whereas the light sector employs asqtad staggered fermions. We extrapolate our results to the physical point in the continuum limit using rooted staggered heavy-light meson chiral perturbation theory. Then we apply a model-independent parametrization to extend the form factors to the full kinematic range. With this parametrization we perform a joint lattice-QCD/experiment fit using several experimental datasets to determine the CKM matrix element $$|V_{cb}|$$ | V cb | . We obtain $$\left| V_{cb}\right| = (38.40 \pm 0.68_{\text {th}} \pm 0.34_{\text {exp}} \pm 0.18_{\text {EM}})\times 10^{-3}$$ V cb = ( 38.40 ± 0 . 68 th ± 0 . 34 exp ± 0 . 18 EM ) × 10 - 3 . The first error is theoretical, the second comes from experiment and the last one includes electromagnetic and electroweak uncertainties, with an overall $$\chi ^2\text {/dof} = 126/84$$ χ 2 /dof = 126 / 84 , which illustrates the tensions between the experimental data sets, and between theory and experiment. This result is in agreement with previous exclusive determinations, but the tension with the inclusive determination remains. Finally, we integrate the differential decay rate obtained solely from lattice data to predict $$R(D^*) = 0.265 \pm 0.013$$ R ( D ∗ ) = 0.265 ± 0.013 , which confirms the current tension between theory and experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ICARUS at the Fermilab Short-Baseline Neutrino program: initial operation

The ICARUS collaboration employed the 760-ton T600 detector in a successful 3-year physics run at the underground LNGS laboratory, performing a sensitive search for LSND-like anomalous $\nu _e$ appearance in the CERN Neutrino to Gran Sasso beam, which contributed to the constraints on the allowed neutrino oscillation parameters to a narrow region around 1 eV$^2$. After a significant overhaul at CERN, the T600 detector has been installed at Fermilab. In 2020 the cryogenic commissioning began with detector cool down, liquid argon filling and recirculation. ICARUS then started its operations collecting the first neutrino events from the booster neutrino beam (BNB) and the Neutrinos at the Main Injector (NuMI) beam off-axis, which were used to test the ICARUS event selection, reconstruction and analysis algorithms. ICARUS successfully completed its commissioning phase in June 2022. The first goal of the ICARUS data taking will be a study to either confirm or refute the claim by Neutrino-4 short-baseline reactor experiment. ICARUS will also perform measurement of neutrino cross sections with the NuMI beam and several Beyond Standard Model searches. After the first year of operations, ICARUS will search for evidence of sterile neutrinos jointly with the Short-Baseline Near Detector, within the Short-Baseline Neutrino program. In this paper, the main activities carried out during the overhauling and installation phases are highlighted. Preliminary technical results from the ICARUS commissioning data with the BNB and NuMI beams are presented both in terms of performance of all ICARUS subsystems and of capability to select and reconstruct neutrino events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Muon loss rates from betatron resonances at the Muon g – 2 Storage Ring at Fermilab

The Muon g–2 Experiment at Fermilab (E989) is directed toward measuring the muon magnetic anomaly, a μ = (g–2)/2, with total statistical and systematic errors of 0.14 ppm. Here, this new measurement will serve as strong probe of effects of as yet undiscovered particles beyond the Standard Model (SM), and perhaps validate or disprove other theoretical models beyond the SM. Of special interest is the reduction of muon losses from the storage ring to achieve the precision needed at the Muon g–2 Experiment.

43 PARTICLE ACCELERATORS↗

Experience with crystals at Fermilab accelerators

Crystals were used at Fermilab accelerators for slow extraction and halo collimation in the Tevatron collider, and for channeling radiation generation experiments at the FAST electron linac facility. In this paper we overview past experience and major outcomes of these studies and discuss opportunities for new crystal acceleration R&D program.

43 PARTICLE ACCELERATORS↗

Fermilab Phoebus

The Fermilab Phoebus code contains FNAL site-specific code to customize the Control Systems Studio Phoebus application. Phoebus is a tool used to create and present graphical displays based on current real-time and historic values of sensors, gauges, alarms, and many other devices in accelerators and physics experiments here and at other laboratories around the world.

Velarde, Mariana González [Fermi National Accelera↗

An Energy-Integrated Analysis for Measuring the Anomalous Precession Frequenzc for the Muon g - 2 Experiment at Fermilab

In the search for physics beyond the Standard Model, the Muon g - 2 Experiment at Fermilab (E989) will make the most precise measurement of the anomalous magnetic moment of the muon, a μ . Improvements in precision come from both increased statistics and new techniques to significantly reduce previous systematic uncertainties. The muon a μ is determined by extracting both the anomalous spin precession frequency, ω a , and the average magnetic field sampled by the muons, B. Traditionally an energy threshold analysis method which requires reconstruction of decay positrons from the muon decay, μ + → e + ν e ν μ has been used to extract ω a . This thesis will describe a novel, energy-integrated analysis method for ωa extraction that does not require full reconstruction of positron hits and lowers the energy threshold therefore sampling more of the stored muons. This new technique has different sensitivities to effects like gain fluctuations and positron pulse pile-up. The analysis results will focus on data taken in 2019, the second year of running the experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Mu2e experiment at Fermilab: Design and status

The Mu2e experiment at Fermilab will search for coherent, neutrinoless conversion of negative muons into electrons in the field of an aluminum nucleus. The dynamics of such charged lepton flavour violating (CLFV) process is a twobody decay, resulting in a mono-energetic electron with an energy slightly below the muon rest mass. If no events are observed in three years of running, Mu2e will set an upper limit on the ratio between the conversion and the capture rates Rμe of ≤ 6 × 10 -17 (@90% C.L.). This will improve the current limit of four order of magnitudes with respect to the previous best experiment. Mu2e complements and extends the current search for μ → eγ decay at MEG as well as the direct searches for new physics at the LHC. Indeed, such a CLFV process probes new physics at a scale inaccessible to direct searches at either present or planned high energy colliders. Observation of a signal will be a clear evidence for new physics beyond the Standard Model. To search for the muon conversion process, a very intense pulsed beam of negative muons (~ 10 10 μ/s) is stopped on an aluminum target inside a very long solenoid where the detector is also located. The Mu2e detector is composed of a straw tube tracker and an electromagnetic calorimeter consisting of arrays of CsI crystals. An external veto for cosmic rays is surrounding the detector solenoid. In 2016, Mu2e has passed the final approval stage from DOE and has started its construction phase. Data collection is planned for the end of 2021. Lastly, an overview of the physics motivations for Mu2e, the current status of the experiment and design of the muon beam-line and the detector is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser calibration system for the Muon g-2 Experiment at Fermilab

Muon g-2 experiment at Fermilab is going to measure the anomalous magnetic moment of the muon with a precision of 0.14 ppm like never before. This fourfold precision goal compared to the previous g-2 experiment at BNL required improvements in all fronts, a big part of which will come from the gain correction of the SiPM-based calorimeters using a complex laser calibration system developed by INFN.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fermilab Muon $g - 2$ experiment: Current status

The Muon $g$ - 2 experiment at Fermilab (E989) is currently measuring the muon magnetic anomaly with a goal precision of 140 part per billion, which will be a fourfold precision improvement over the current best measurement by the previous Muon $g$ -2 experiment at the Brookhaven Laboratory (BNL). The BNL-measured value of the muon magnetic anomaly and the corresponding Standard Model (SM) best estimate differ by more than three standard deviation which inspired the current measurement as well as a theoretical drive for a significantly more precise calculation of the muon magnetic anomaly to rule out (or establish) statistical fluctuation as the origin of such a huge discrepancy. Stable central values along with 4-fold precision improvements in both theoretical (SM) and experimental fronts, would imply a ~ 7σ discrepancy and that will be a clear hint of the physics beyond the Standard Model. Such an unprecedented precision demands state-of-the-art technological improvements in all involved components to keep the systematic uncertainty below 70 ppb. This paper reports the current status of the E989 experiment after two years of data acquisition.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the anomalous spin precession frequency $\omega_a$ in the Muon g - 2 experiment at Fermilab

The muon magnetic anomaly aµ = (gµ - 2)/2 is a low-energy observable,which can be both measured and computed to high precision, making ita sensitive test of the Standard Model (SM). In April 2021, the E989 Collaborationat Fermilab National Accelerator Laboratory (FNAL) published the first resultbased on the first year of data taking (Run-1), and in August 2023 a new resultwas published based on two more years of data taking (Run-2 and Run-3). Thenew result was in agreement with the first one and with the previous experimentat Brookhaven National Laboratory (BNL), and the combination of these resultsbrought the uncertainty on the experimental measurement of aµ to the unprecedentedvalue of 0.19 parts per million (ppm). This paper will present details aboutthe improvements and upgrades since the 2021 result, and it will describe the finalstatistical and systematic sources of uncertainty on .a in the 2023 result.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modelling Curvilinear Beamline Effects on Beam- and Spin-Dynamics in the Fermilab Muon g-2 Storage Ring.

A model of the Fermilab Muon g-2 Experiment storage ring is developed with the BMAD simulation library for beam- and spin-dynamics studies. Particular focus is given to the electrostatic quadrupoles, the plates of which follow the curvature of the particle design trajectory of the magnetically uniform storage ring. To model these, standard electric multipoles and a novel method based on cylindrical harmonics are investigated and found to accurately match the electric field maps produced for the bulk and fringe regions of the curved quadrupoles respectively, despite these methods being specifically for straight beamlines. The toroidal multipole description is then developed, to include curvature and longitudinal field variations (to model the fringe field regions). Various combinations of the different descriptions (including use of the field maps) are used for the bulk and fringe fields of the quadrupoles, and the toroidal multipoles are found to provide the best agreement with the measured tunes of the storage ring. Two integrators are also developed, based on the method of Wu, Forest and Robin. The first of these describes motion in a uniform magnetic dipole field with arbitrary electric field, and produces results comparable to those of the adaptive-step fourth-order Runge–Kutta integrator implemented in BMAD, suitable for tracking over thousands of turns. The second is a generalisation of the first to arbitrary magnetic vector potentials superimposed on that of the uniform dipole, with arbitrary electric fields, and was also found to agree with the Runge–Kutta integrator. Simulations of antimuon storage for 2000 turns of the storage ring were performed, where losses were studied along with the evolution of beam polarisation. The storage losses, important for reducing the systematic error in the measurement of the muon g-2, were found to be largely due to collimator shape. The correlation between momentum and spin precession frequency reflect the effects expected from the electric field correction in the T-BMT equation, on the order of 10 -6 . Particle injection was also studied, for various injection angles, quadrupole strengths and strengths of injection kick, and in the cases where experimental data was provided, the model was found to be consistent with the experiment.

43 PARTICLE ACCELERATORS↗

Muon-neutrino disappearance with multiple liquid argon time projection chambers in the Fermilab Booster neutrino beam

The Short Baseline Neutrino (SBN) program consists of three liquid argon time projection chamber (LArTPC) experiments: SBND, MicroBooNE and ICARUS, with 110 m, 470 m and 600 m baselines respectively. The detectors are located in the Booster Neutrino Beam (BNB) at Fermilab which has a peak energy around 0.7 GeV and contains predominantly muon neutrinos. The baseline and energy range of the SBN program is conducive to measuring neutrino oscillation parameters under various sterile neutrino hypotheses. Sterile neutrinos have been proposed as a possible solution to the numerous short baseline anomalies. The proposed particles must be sterile in nature such that they do not interact via the weak force, however they may undergo oscillations with the active neutrino flavours. Their existence may consequently be confirmed through measurements of the appearance and disappearance of the active flavours. The analyses presented in this thesis aimed to calculate and understand the sensitivity of the SBN program to measuring the ?µ disappearance parameters under the (3+1) sterile neutrino oscillation hypothesis. The sensitivity of SBN to measuring the ?µ disappearance sterile oscillation parameters, sin2 2?µµ, ?m2 41, was calculated through semi-exclusive joint fits of the ?µ CC 0p and ?µ CC Other reconstructed neutrino energy spectra. The first iteration used truth-level Monte Carlo (MC) events, and determined that the 5s SBN sensitivity is comparable to the 90% MINOS/MINOS+ confidence level and supersedes the 90% MiniBooNE confidence level across entire phase space. Semi-exclusive joint fits of the aforementioned sample spectra were performed between the MC and multiple mock data sets in SBND. This analysis assessed the accuracy with which the near detector can disentangle systematic from physics effects in the oscillation analysis. The result was a 5.49% discrepancy between the ICARUS Monte Carlo and mock data event rates, when the systematic constraints from the near detector fit were extrapolated to the far detector. The second iteration of the SBN sensitivity analysis involved the application of an event selection procedure developed in SBND, following the full reconstruction chain. ?µ CC 0p events were selected from sample of neutrinos with 84.5% efficiency and 84.3% purity. The sterile neutrino sensitivity was determined once more at the near detector with these samples, and was shown to be consistent with the truth-level studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗