Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fire Protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Lightweight, Actively Cooled Ceramic Matrix Composite Thrustcells Successfully Tested in Rocket Combustion Lab

In a joint effort between the NASA Glenn Research Center and the NASA Marshall Space Flight Center, regeneratively cooled ceramic matrix composite (CMC) thrustcells were developed and successfully tested in Glenn's Rocket Combustion Lab. Cooled CMC's offer the potential for substantial weight savings over more traditional metallic parts. Two CMC concepts were investigated. In the first of these concepts, an innovative processing approach utilized by Hyper-Therm, Inc., allowed woven CMC coolant containment tubes to be incorporated into the complex thruster design. In this unique design, the coolant passages had varying cross-sectional shapes but maintained a constant cross-sectional area along the length of the thruster. These thrusters were silicon carbide matrix composites reinforced with silicon carbide fibers. The second concept, which was supplied by Ceramic Composites, Inc., utilized copper cooling coils surrounding a carbon-fiber-reinforced carbon matrix composite. In this design, a protective gradient coating was applied to the inner thruster wall. Ceramic Composites, Inc.'s, method of incorporating the coating into the fiber and matrix eliminated the spallation problem often observed with thermal barrier coatings during hotfire testing. The focus of the testing effort was on screening the CMC material's capabilities as well as evaluating the performance of the thermal barrier or fiber-matrix interfacial coatings. Both concepts were hot-fire tested in gaseous O2/H2 environments. The test matrix included oxygen-to-fuel ratios ranging from 1.5 to 7 with chamber pressures to 400 psi. Steady-state internal wall temperatures in excess of 4300 F were measured in situ for successful 30-sec test runs. Photograph of actively cooled composite thrustcell fabricated by Hyper-Therm is shown. The thrustcell is a silicon-carbide-fiber-reinforced silicon carbide matrix composite with woven cooling channels. The matrix is formed via chemical vapor infiltration. Photograph of hot-fire test of an actively cooled carbon-fiber-reinforced carbon matrix composite thrustcell is also shown. This composite thrustcell, which was fabricated by CCI, Inc., was wound with copper cooling coils to contain the water coolant. The tests were run with oxygen fuel ratios up to seven with chamber pressures of 200 psia.

Jaskowiak, Martha H.↗

Technoeconomic Optimization of Waste Heat Driven Forward Osmosis for Flue Gas Desulfurization Wastewater Treatment

With the Environmental Protection Agency’s recent Effluent Limitation Guidelines for Steam Electric Generators, power plants are having to install and operate new wastewater technologies. Many plants are evaluating desalination technologies as possible compliance options. However, the desalination technologies under review that can reduce wastewater volume or treat to a zero-liquid discharges standard have a significant energy penalty to the plant. Waste heat, available from the exhaust gas or cooling water from coal-fired power plants, offers an opportunity to drive wastewater treatment using thermal desalination technologies. One such technology is forward osmosis (FO). Forward osmosis utilizes an osmotic pressure gradient to passively pull water from a saline or wastewater stream across a semi-permeable membrane and into a more concentrated draw solution. This diluted draw solution is then fed into a distillation column, where the addition of low temperature waste heat can drive the separation to produce a reconcentrated draw solution and treated water for internal plant reuse. The use of low-temperature waste heat decouples water treatment from electricity production and eliminates the link between reducing water pollution and increasing air emissions from auxiliary electricity generation. In order to evaluate the feasibility of waste heat driven FO, we first build a model of an FO system for flue gas desulfurization (FGD) wastewater treatment at coal-fired power plants. This model includes the FO membrane module, the distillation column for draw solution recovery, and waste heat recovery from the exhaust gas. We then add a costing model to account for capital and operating costs of the forward osmosis system. We use this techno-economic model to optimize waste heat driven FO for the treatment of FGD wastewater. We apply this model to three case studies: the National Energy Technology Laboratory (NETL) 550 MW model coal fired power plant without carbon capture and sequestration, the NETL 550 MW model coal fired power plant with carbon capture and sequestration, and Plant Bowen in Eularhee, Georgia. For each case, we identify the design that minimizes the cost of wastewater treatment given the safely recoverable waste heat. We benchmark the cost minimum waste-heat forward osmosis solutions to two conventional options that rely on electricity, reverse osmosis and mechanical vapor recompression. Furthermore, we quantify the environmental damages from the emissions of carbon dioxide and criteria air pollutants for each treatment option. With this information we can assess the trade-offs between treatment costs, energy consumption, and air emissions between the treatment options.

20 FOSSIL-FUELED POWER PLANTS↗

Containment Chamber Systems Engineering Project

Lawrence Livermore National Laboratory (LLNL) is a leading research laboratory in material properties. The most notable facility at LLNL capable of determining equation of state data for hazardous materials is the National Ignition Facility (NIF). NIF is the most energetic laser in the world and is a very versatile system that allows for a variety of laser configurations and diagnostics. The flexibility that NIF offers makes it an attractive tool for high budget programs researching specific areas of interest. Some programs require many tests to be performed, and although NIF could be an option for performing these tests, the cost and time to perform the tests would not be feasible. Also, many of these tests would underutilize the full capacity of NIF’s lasers, and NIF does not have a dedicated light source suitable for the diagnostic requirement. The needs of these tests do not align with NIF’s capabilities. The physicists are the main stakeholders for the tests, and they require a third-generation light source to meet the desired diagnostic performance. The Dynamic Compression Sector (DCS) within the Advanced Photon Source (APS) at Argonne National Laboratory (ANL) is the facility that will meet necessary laser performance and the X-ray diagnostic performance in order to obtain the desired data. DCS does not have the capability to test hazardous material, and therefore DCS requires a method and hardware for ensuring that no hazardous material is exposed before, during, or after the test. After taking a system engineering evaluation of the need for a solution to perform laser shock experiments on hazardous materials with certain laser and X-ray characteristics, a solution is proposed that meets the requirements of each involved stakeholder. The proposed solution is to contain the targets within sealed vacuum chamber that will meet the protection requirements of each facility. The chamber would be assembled and pumped down at LLNL in facilities that can handle hazardous material. Then, the chamber would be shipped under vacuum to DCS, where the chamber will be inserted into the beam paths. DCS’s laser will enter the sealed chamber and impart a shock into the target of hazardous material while the X-ray will simultaneously image the material. Once each target has been fired, the chamber will be removed from the beam path and shipped to the proper disposal facility.

42 ENGINEERING↗

High-Temperature Oxidation Behavior of Wrought and Additive Manufactured Alloys in Direct-Fired Supercritical CO2 Power Cycle Environments

Materials selection is a key concern for corrosion resistance in elevated temperature and pressure direct-fired supercritical CO2 (sCO2) power cycles. The effect of elevated pressure on corrosion resistance can be critical, as impurities within the supercritical fluid such as H2O and O2 can have additional corrosion effects than found at ambient pressure conditions. Several wrought nickel-based commercial alloys (230, 263, 282, 617, 625, 740H) were exposed to direct-fired conditions (95CO2 – 4H2O – 1 O2) at 750 °C at both atmospheric pressure (0.1 MPa) and supercritical conditions (20 MPa) for over 2,000 h. Additionally, additive manufactured (AM) 282 produced by laser powder bed fusion (LPBF) were also included in the exposures. Supercritical conditions affected the oxidation behavior of several alloys. Most notably, water-vapor assisted Cr-oxide volatilization was observed at 750 °C supercritical conditions. Many alloys did not form sufficient protective Cr-oxide scales at supercritical conditions, leading to increased oxidation at elevated pressure. Differences in oxidation behavior were also observed for 282 AM samples compared to their wrought counterparts, with the differences also dependent on the LPBF build parameters and post-production treatments (heat treatment and surface finishing procedures). The AM samples formed Mo-rich carbides in the alloy beneath the oxide following sCO2 exposure, implying potentially higher levels of carbon uptake relative to the wrought

Carney, Casey↗

Comprehensive Air Monitoring Report for Measurements during the Las Conchas Fire at Los Alamos National Laboratory

During the Las Conchas Fire, ambient air was monitored for radionuclides and particulate matter at and around Los Alamos National Laboratory (the Laboratory). During the fire, a variety of samplers were deployed, including the radiological air sampling network, high-volume air samplers, Tapered Element Oscillating Microbalances (PM 2.5 and PM 10), and environmental continuous air monitors. These different types of samplers provided real time, more in-depth retrospective information on air quality. In total, roughly 220 air samples were collected, and the results were consistent with other regional fires. Laboratory officials and Los Alamos County used real-time data to make public health risk determinations according to the Air Quality Index. Particulate levels were elevated and exceeded the National Ambient Air Quality Standard during the fire because of smoke. Elevated levels of naturally occurring radon decay products, consistent with all forest fires, were detected. Gross-alpha measurements had an average of range of 400 aCi/m 3 to 13,400 aCi/m 3 . Measurements of gross beta during the fire had a range of 34,000 aCi/m 3 to 74,000 aCi/m 3 . These values are not statistically different from national or regional averages.

54 ENVIRONMENTAL SCIENCES↗

Prototype Ceramic HEPA Filter Testing and Filter Media Research and Development for Nuclear Facility Ventilation

This is a brief summary of recent and past Ceramic HEPA Filter research and development activities under an NNSA NSR&D funded project and describes on-going plans for FY19 work as presently planned. Prior work has evaluated concepts for a ceramic HEPA filter including ceramic support materials, filter media including electrospun filter media, and metal housing designs to accommodate the conservative temperature performance target of up to 500°C. This has been supported by modelling efforts discussed with nuclear facility system engineers and their management. The temperature and time-attemperature are based on conservative, bounding temperatures from fire analysis presented as an EFCOG best practice paper for nuclear facility safety analysis. The overall goal is to improve safety of DOE nuclear facilities during fire scenarios by developing improved filtration technology including increasing temperature performance while maintaining acceptable filter pressure drop. Ceramic filtration technology can provide robust, passive mitigation against radiological releases. The goal of the ceramic HEPA filter is to provide a HEPA filter that provides increased temperature performance in an equivalent form factor (size and shape) that is similar to existing conventional HEPA filters used in facilities. Once development is complete and qualified for use in facilities, ceramic HEPA filters could simplify and reduce safety and support system costs, as well as lower life-cycle costs. Installation, monitoring, and maintenance of active fire suppression systems, as well as other related systems, are a considerable on-going cost to nuclear facilities. Reducing the level of dependence on Safety Class and Safety Significant fire alarm and fire suppression systems could allow significant cost savings. At present we are continuing research and development efforts towards the goal of a ceramic filter design, including improved ceramic filter media, that could reduce total operation cost for facilities utilizing HEPA filters.

36 MATERIALS SCIENCE↗

Orion Exploration Flight Test Reaction Control System Jet Interaction Heating Environment from Flight Data

The Orion Multi-Purpose Crew Vehicle (MPCV) Reaction Control System (RCS) is critical to guide the vehicle along the desired trajectory during re-­‐entry. However, this system has a significant impact on the convective heating environment to the spacecraft. Heating augmentation from the jet interaction (JI) drives thermal protection system (TPS) material selection and thickness requirements for the spacecraft. This paper describes the heating environment from the RCS on the afterbody of the Orion MPCV during Orion's first flight test, Exploration Flight Test 1 (EFT-1). These jet plumes interact with the wake of the crew capsule and cause an increase in the convective heating environment. Not only is there widespread influence from the jet banks, there may also be very localized effects. The firing history during EFT-1 will be summarized to assess which jet bank interaction was measured during flight. Heating augmentation factors derived from the reconstructed flight data will be presented. Furthermore, flight instrumentation across the afterbody provides the highest spatial resolution of the region of influence of the individual jet banks of any spacecraft yet flown. This distribution of heating augmentation across the afterbody will be derived from the flight data. Additionally, trends with possible correlating parameters will be investigated to assist future designs and ground testing programs. Finally, the challenges of measuring JI, applying this data to future flights and lessons learned will be discussed.

White, Molly E.↗

Autonomous Strategies for Improved Performance and Reliability of Li‐Ion Batteries

Abstract The battery community has devoted significant effort to improve the performance and reliability of Li‐ion batteries through the development of new materials. The integration of autonomous function provides an alternative strategy to further extend performance. Autonomous material systems mimic the ability of biological systems to self‐protect, sense, regulate, and heal in response to damage and other environmental changes. When incorporated in batteries, these materials enable autonomic restoration of battery performance upon degradation, as well as autonomic shutdown or extinguishment in response to thermal runaway. Successful strategies for improving Li‐ion battery performance include controlled release of microencapsulated functional additives and the integration of self‐healing or adaptive interlayers and binders. These methods have been effective for stabilizing the solid electrolyte interface, preventing battery fires, restoring electrode conductivity, and suppressing Li dendrite growth. Challenges and opportunities exist in the further application of autonomous strategies in the battery environment. A greater variety of encapsulated additives with precise triggered‐release are needed to address specific battery degradation mechanisms. Incorporation of self‐healing polymers in solid‐state batteries facilitates improvement in interfacial and mechanical stability. The integration of autonomous strategies with battery management systems potentially enables enhanced control over multiple battery cycling parameters.

Zhao, Lihong↗

Fire- and Water-Resistant Prefilter

The goal of this project was to modify existing LLNL ceramic HEPA filter technology to create ceramic prefilters, which could first be implemented in nuclear facilities or hospitals and universities. The objectives were as follows: 1) Demonstrate sealing technology capable of withstand ≥ 400°C, 2) Design and fabricate a ceramic prefilter unit for flow rates ≥ 50 cfm, 3) Test prefilter prototype filtration efficiency and pressure drop before and after a relevant thermal exposure. Concurrently to prototype creation was a preliminary effort to develop a custom nuclear prefilter sealant, improving upon what is commercially available. An advantage to using prefilters that are not credited for HEPA filtration, but to protect HEPA filters in nuclear ventilation systems, is that absolute qualified performance to HEPA standards (e.g. pressure drop, filtration efficiency) is not required. This prefilter prototype aligns our technology with the more viable, lower risk market entry point which can be used to establish costs, performance and manufacturing principles necessary to overcome the primary market barrier.

36 MATERIALS SCIENCE↗

Review: The distribution, flow, and quality of Grand Canyon Springs, Arizona (USA)

An understanding of the hydrogeology of Grand Canyon National Park (GRCA) in northern Arizona, USA, is critical for future resource protection. The ~750 springs in GRCA provide both perennial and seasonal flow to numerous desert streams, drinking water to wildlife and visitors in an otherwise arid environment, and habitat for rare, endemic and threatened species. Spring behavior and flow patterns represent local and regional patterns in aquifer recharge, reflect the geologic structure and stratigraphy, and are indicators of the overall biotic health of the canyon. These springs, however, are subject to pressures from water supply development, changes in recharge from forest fires and other land management activities, and potential contamination. Roaring Springs is the sole water supply for residents and visitors (>6 million/year), and all springs support valuable riparian habitats with very high species diversity. Most springs flow from the karstic Redwall-Muav aquifer and show seasonal patterns in flow and water chemistry indicative of variable aquifer porosities, including conduit flow. They have Ca/Mg-HCO{sub 3} dominated chemistry and trace elements consistent with nearby deep wells drilled into the Redwall-Muav aquifer. Tracer techniques and water-age dating indicate a wide range of residence times for many springs, supporting the concept of multiple porosities. A perched aquifer produces small springs which issue from the contacts between sandstone and shale units, with variable groundwater residence times. Stable isotope data suggest both an elevational and seasonal difference in recharge between North and South Rim springs. This review highlights the complex nature of the groundwater system.

54 ENVIRONMENTAL SCIENCES↗

Environmental and Radiological Readiness of Fixatives, Foams, and Intumescent Coatings for D and D Applications - 18553

During D and D operations of legacy nuclear facilities, the ability to effectively stabilize contamination in large cavities is a significant challenge. For items that must be removed, such as gloveboxes and entry hoods, a method of simply filling the volume to stabilize any residual contamination after contamination efforts have concluded would be of great benefit, and further the As Low As Reasonably Achievable (ALARA) culture of the DOE complex. The development, testing, and characterization of commercial fixatives and foams for applicability towards fixating contamination provides a potential structural reinforcement and fire resiliency in legacy nuclear facility equipment. Much of the equipment, such as gloveboxes, shielded cells, and radiological hoods left over from nuclear processing leave large cavities. Filling these voids after decontamination efforts provides a means of shielding workers from excess radiation exposure while immobilizing residual contamination. As such, we look to continue the development of fixatives/intumescent coatings from the previous year and test commercially available polymer-based foam products for use in filling these cavities, providing a secondary level of protection and shielding during the D and D process This research is funded as part of the In-Situ Decommissioning and Technology Development and sponsored by DOE- Office of Environmental Management Technology Development. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Remaining Sites Verification Package for the 600-111, P-11 Critical Mass Laboratory Crib, and UPR-600-16, Fire and Contamination Spread Waste Sites, Waste Site Reclassification Form 2004-065

The 600-111, P-11 Critical Mass Laboratory Crib waste site, also referred to as the P-11 Facility, included the 120 Experimental Building, the 123 Control Building, and the P-11 Crib. The facility was constructed in 1949 and was used as a laboratory for plutonium criticality studies. In accordance with this evaluation, the confirmatory and verification sampling results support a reclassification of this site to Interim Closed Out. The results of confirmatory and verification sampling show that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Effect of Shot Peening on Steam Oxidation of 304H Stainless Steel

Shot peening is currently utilized in coal-fired power plant components to mitigate scale exfoliation issues from steamside oxidation of austenitic stainless steel superheater and reheater tubing. To focus on commercially available material, this study exposed quarter-ring specimens cut from two different commercially shot peened type 304H tubes and exposed to 1 bar steam for up to 15,000 h at 550°, 600°, 625°, and 650 °C. Specimens were removed at increments to characterize the oxide thickness and microstructure. The shot peened inner surface generally retained a thin, protective Cr-rich scale with occasional Fe-rich oxide nodules at 550–625 °C. The increased oxidation resistance from shot peening began to degrade at 650 °C after as little as 5,000 h. Cut and polished faces of these specimens formed thick, Fe-rich oxides similar to polished 304H coupons. Surprisingly, the mechanically machined outer surface of the tube specimens performed similarly to the shot peened inner diameter, suggesting it had sufficient cold work to achieve a similar benefit. As a result, electron backscatter diffraction and Vickers-hardness measurements were used to characterize post-exposure changes in underlying microstructure and mechanical properties, respectively, imparted by shot peening.

36 MATERIALS SCIENCE↗

Advanced Health Management System for the Space Shuttle Main Engine

Pratt & Whitney Rocketdyne, Inc., in cooperation with NASA-Marshall Space Flight Center (MSFC), has developed a new Advanced Health Management System (AHMS) controller for the Space Shuttle Main Engine (SSME) that will increase the probability of successfully placing the shuttle into the intended orbit and increase the safety of the Space Transportation System (STS) launches. The AHMS is an upgrade o the current Block II engine controller whose primary component is an improved vibration monitoring system called the Real-Time Vibration Monitoring System (RTVMS) that can effectively and reliably monitor the state of the high pressure turbomachinery and provide engine protection through a new synchronous vibration redline which enables engine shutdown if the vibration exceeds predetermined thresholds. The introduction of this system required improvements and modification to the Block II controller such as redesigning the Digital Computer Unit (DCU) memory and the Flight Accelerometer Safety Cut-Off System (FASCOS) circuitry, eliminating the existing memory retention batteries, installation of the Digital Signal Processor (DSP) technology, and installation of a High Speed Serial Interface (HSSI) with accompanying outside world connectors. Test stand hot-fire testing along with lab testing have verified successful implementation and is expected to reduce the probability of catastrophic engine failures during the shuttle ascent phase and improve safely by about 23% according to the Quantitative Risk Assessment System (QRAS), leading to a safer and more reliable SSME.

Davidson, Matt↗

Tank Side Cesium Removal IXC-150 Cask Detonation Report

A set of experiments were conducted at Los Alamos National Laboratory’s firing point 88 to determine the blast pressure and effects of a stoichiometric gas mixture of Hydrogen (H 2 ) and Nitrous Oxide (N 2 O) on the IXC-150 Storage Pad Vent Stack assemblies. The Lab was asked to design, build, and test the vent stack assemblies using a reaction gas volume of 340 in 3 that mimics the Tank Side Cesium Removal (TSCR) Ion Exchange Column (IXC) assembly. The experimental system with vent stack assembly was designed with input from the Washington River Protection Services (WRPS) to ensure an accurate test setup. The tests were conducted at LANL on the newly built filter/gas assembly at the end of April 2021 timeframe, using WRPS supplied vent stack assemblies and internal HEPA filters. The objective of these tests was to observe that the structural integrity of the vent stack assemblies was maintained and determine the resulting blast overpressures at a distance of 16 and 32 inches from the assembly. All work was performed under the LANL Quality Assurance Program (SD330), using a graded application of ASME NQA-1- 2008/NQA-1a-2009. To ensure that all client quality assurance (QA) expectations were addressed, evaluation of the end data needs was performed and the appropriate controls applied for this work.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Corrosion of novel reactive silver ink and commercial silver-based metallizations in diluted acetic acid

Silver-based metallizations in photovoltaic modules are susceptible to corrosion by acetic acid generated in ethylene vinyl acetate encapsulated modules, resulting in power losses over time. Here, three silver-based metallizations are exposed to diluted acetic acid, in concentrations representative of that found in field-exposed modules. Compositional, morphological, and structural changes of the metallizations are studied over 3000 h of exposure to diluted acetic acid using Raman spectroscopy mapping, X-ray diffraction, and scanning electron microscopy. The three metallizations studied are: 1) a commercial high-temperature fire-through Ag paste, commonly used for Si diffused junction solar cells; 2) a commercial low-temperature paste normally used for silicon heterojunction cells; and 3) a novel low-temperature reactive silver ink shown to be suitable for photovoltaic applications. We find distinct corrosion rates for the high-temperature silver paste and reactive silver ink in the presence of diluted acetic acid. However, the low-temperature silver paste appears to be more corrosion resistant, likely due to a polymer layer that protects the silver particles.

36 MATERIALS SCIENCE↗

2013 R&D 100 Award: 'SHIELD' protects NIF optics from harmful pulses

In the past, it took as long as 12 hours to manually screen 48 critical checkpoints at the National Ignition Facility (NIF) for harmful laser pulses. The screening equipment had to be moved from point to point throughout a facility the size of three football fields. Now with a new technology, called Laser SHIELD (Screening at High-throughput to Identify Energetic Laser Distortion), and with the push of a button, the screening can be done in less than one second. Proper screening of pulses is critical for the operation of high-energy lasers to ensure that the laser does not exceed safe operating conditions for optics. The energetic beams of light are so powerful that, when left uncontrolled, they can shatter the extremely valuable glass inside the laser. If a harmful pulse is found, immediate adjustments can be made in order to protect the optics for the facility. Laser SHIELD is a custom-designed high-throughput screening system built from low-cost and commercially available components found in the telecommunications industry. Its all-fiber design makes it amenable to the unique needs of high-energy laser facilities, including routing to intricate pick-off locations, immunity to electromagnetic interference and low-loss transport (up to several kilometers). The technology offers several important benefits for NIF. First, the facility is able to fire more shots in less time-an efficiency that saves the facility millions of dollars each year. Second, high-energy lasers are more flexible to wavelength changes requested by target physicists. Third, by identifying harmful pulses before they damage the laser's optics, the facility potentially saves hundreds of thousands of dollars in maintenance costs each year.

42 ENGINEERING↗

Development of a Nitrogen and Magnesium Oxide based Class A, B & D Suffocating Fire System (SFSS) for Gloveboxes

Testing related to the development and performance of a “Proof of Concept” Nitrogen/Magnesium Oxide Suffocating Fire System (SFSS) was conducted at Fire and Pump Service Group (FPSG) located in Rancho Dominguez, California. The SFSS Engineering Team (SFSSET), consisting of FPSG and Los Alamos National Laboratory (LANL) personnel researched, developed a prototype, and conducted testing to determine effective means to deliver magnesium oxide (MgO) sand into a glovebox (GB) in a class D fire event. The prototypes development also established the effective coverage area of a magnesium oxide suppression system as well as demonstrated that the GB inert atmosphere could be maintained during and after the release of the MgO sand to control Class A, B and D fires. Previous testing conducted on nitrogen based SFSS provided evidence that the nitrogen based SFSS controlled Class A and B fires (Ralph Clayton, Los Alamos National Laboratory, Brandon Troc and Frank Broidy, Fire and Pump Service Group 2020).Final testing was conducted within a mock GB capable of simulating an inert glovebox atmosphere. Testing demonstrated that the inert atmosphere can be maintained during and after discharge of the MgO sand over a coverage area.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗