Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fire Simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Cooperative carbon capture and steam regeneration with tetraamine-appended metal–organic frameworks

Natural gas has become the dominant source of electricity in the United States, and technologies capable of efficiently removing carbon dioxide (CO 2 ) from the flue emissions of natural gas–fired power plants could reduce their carbon intensity. However, given the low partial pressure of CO 2 in the flue stream, separation of CO 2 is particularly challenging. Taking inspiration from the crystal structures of diamine-appended metal–organic frameworks exhibiting two-step cooperative CO 2 adsorption, we report a family of robust tetraamine-functionalized frameworks that retain cooperativity, leading to the potential for exceptional efficiency in capturing CO 2 under the extreme conditions relevant to natural gas flue emissions. The ordered, multimetal coordination of the tetraamines imparts the materials with extraordinary stability to adsorption-desorption cycling with simulated humid flue gas and enables regeneration using low-temperature steam in lieu of costly pressure or temperature swings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Process for CO2 Capture Using Ionic Liquid That Exhibits Phase Change

A novel process for capturing carbon dioxide from the flue gas of a coal-fired power plant has been shown to reduce parasitic power consumption substantially. The process employs an ionic liquid created at the University of Notre Dame that has a high capacity for absorbing CO2 by chemical reaction. A distinguishing property of this ionic liquid is that it changes phase from solid to liquid upon reaction with CO2. The process uses heat generated by this phase transition to lower parasitic power consumption. The driving force for CO2 separation is a combination of temperature and pressure differences; the process could even work without the addition of heat. A realistic process was created to capture CO2 efficiently. Computer simulation of the process enabled calculation of viable process conditions and power usage. The main concepts of the process were shown to work using a lab-scale apparatus. Parasitic power consumes 23% of net power generation, 55% lower than that of the monoethanolamine (MEA) process. However, capital cost is higher. The cost of electricity (COE) is 28% lower than that of the MEA process.

Eisinger, RS↗

Reinventing Design Principles for Developing Low-Viscosity Carbon Dioxide-Binding Organic Liquids for Flue Gas Clean Up

Anthropogenic carbon dioxide (CO 2 ) emission from point sources, such as coal fired-power plants, account for the majority of the green houses gasses in the atmosphere. Capture, storage and utilization are required to mitigate adverse environmental effects. Aqueous amine-based CO 2 capture solvents are currently considered the industry standard, but deployment to market is limited by their high regeneration energy demand. In that context, energy efficient and less-viscous water-lean transformational solvent systems known as CO 2 Binding Organic Liquids (CO 2 BOLs) are being developed in our group to advance this technology to commercialization. Herein, we present a logical design approach based on fundamental concepts of organic chemistry and computer simulations aimed at lowering solvent viscosity. Conceptually, viscosity reduction would be achieved by systemmatic methods such as introduction of steric hindrance on the anion to minimize the intermolecular cation-anion interactions, fine tuning the electronics, hydrogen bonding orientation and strength, and charge solvation. Conventional standard trial-and-error approaches while effective, are time consuming and economically expensive. Herein, we rethink the metrics and design principles of low-viscosity CO 2 capture solvents using a combined synthesis and computational modeling approach. We critically study the impacts of modyfying factors such as as orientation of hydrogen bonding, introduction of higher degrees of freedom and cation or anion charge solvation and assess if or how each factor impacts viscosity of CO 2 BOL CO 2 capture solvents. Ultimately, we found that hydrogen bond orientation and strength is predominantly influencing the viscosity in CO 2 BOL solvents. With this knowledge, a new 1-MEIPADM-2-BOL CO 2 BOL variant was synthesized and tested, resulting in a solvent that is approximately 60% less viscous at 25 mol% CO 2 loading with respect to our base compound 1-IPADM-2-BOL. The insights gained from the current study redefines the fundamental concepts and understanding of what influences viscosity in concentrated organic CO 2 capture solvents.

54 ENVIRONMENTAL SCIENCES↗

Non-methane organic gas emissions from biomass burning: identification, quantification, and emission factors from PTR-ToF during the FIREX 2016 laboratory experiment

Volatile and intermediate-volatility non-methane organic gases (NMOGs) released from biomass burning were measured during laboratory-simulated wildfires by proton-transfer-reaction time-of-flight mass spectrometry (PTR-ToF). We identified NMOG contributors to more than 150 PTR ion masses using gas chromatography (GC) pre-separation with electron ionization, H 3 O + chemical ionization, and NO + chemical ionization, an extensive literature review, and time series correlation, providing higher certainty for ion identifications than has been previously available. Our interpretation of the PTR-ToF mass spectrum accounts for nearly 90 % of NMOG mass detected by PTR-ToF across all fuel types. The relative contributions of different NMOGs to individual exact ion masses are mostly similar across many fires and fuel types. The PTR-ToF measurements are compared to corresponding measurements from open-path Fourier transform infrared spectroscopy (OP-FTIR), broadband cavity-enhanced spectroscopy (ACES), and iodide ion chemical ionization mass spectrometry (I - CIMS) where possible. The majority of comparisons have slopes near 1 and values of the linear correlation coefficient, R 2 , of > 0.8, including compounds that are not frequently reported by PTR-MS such as ammonia, hydrogen cyanide (HCN), nitrous acid (HONO), and propene. The exceptions include methylglyoxal and compounds that are known to be difficult to measure with one or more of the deployed instruments. The fire-integrated emission ratios to CO and emission factors of NMOGs from 18 fuel types are provided. Finally, we provide an overview of the chemical characteristics of detected species. Non-aromatic oxygenated compounds are the most abundant. Furans and aromatics, while less abundant, comprise a large portion of the OH reactivity. The OH reactivity, its major contributors, and the volatility distribution of emissions can change considerably over the course of a fire.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanoscale calcium aluminate coated graphite for improved performance of alumina based monolithic refractory composite

Graphical abstract: - Highlights: • Sol–gel Ca-doped γ-Al{sub 2}O{sub 3} accomplished graphite retention. • Nanocoating considerably improved matrix-aggregate bonding. • Less porous simulated matrix upgraded slag resistance. - Abstract: The synthesis and properties of high alumina castable containing nanostructured calcium aluminate coated graphite were studied in terms of slag resistance and overall physical characteristics. Raman spectroscopy, BET surface area and field emission scanning electron microscopy (FESEM) were performed to exclusively understand the coating characteristics and its compatibility in refractory composite. The coating not only secured graphite in castable for prolonged period but also noticeably improved matrix to aggregate contact. The microstructural aspects of castables were investigated, with special emphasis on a representative matrix prepared and infiltrated with slag at elevated temperature. Scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS) of fired composite containing surface-treated graphite was quite prospective. It circumvented the problems of incorporating as-received graphite in castables and should be in the attention of refractory researchers and producers.

36 MATERIALS SCIENCE↗

A model combustor for studying a reacting jet in an oscillating crossflow

This paper discusses a novel model combustion experiment that was built for studying the structure and dynamics of a reacting jet in an unsteady crossflow. A natural-gas-fired dump combustor is used to generate and sustain an acoustically oscillating vitiated flow that serves as the crossflow for transverse jet injection. Unlike most other techniques that are limited in operating pressure or acoustic amplitude, this method of generating an unsteady flow field is demonstrated at a pressure of 10 atm with peak-to-peak oscillation amplitudes approaching 20% of the mean pressure. An optically accessible test section designed for these conditions provides access for advanced laser and optical diagnostic measurements. Detailed measurements provide insight into the complex acoustic-hydrodynamic-combustion coupling processes and offer high-quality, high-resolution validation data for numerical simulations. Careful instrumentation port design considerations for the higher amplitude acoustics are detailed. As a whole, this paper focuses on select representative segments of the experiment operational space that highlight our strategy of providing an oscillatory flowfield. This includes presenting the acoustic operational space such as acoustic amplitudes, frequencies, and mode shapes. Select imaging results are then reported to support our strategies capability to produce high-fidelity measurements.

47 OTHER INSTRUMENTATION↗

Data and scripts associated with “When do Riverine Systems 'Feel the Burn'? Simulating How Burn Extent and Severity Modulate Hydrologic Controls on Biogeochemical Export” (v2)

This data package is associated with the publication “When do Riverine Systems 'Feel the Burn'? Simulating How Burn Extent and Severity Modulate Hydrologic Controls on Biogeochemical Export” published in Water Resources Research (Wampler et al. 2025; preprint: https://doi.org/10.22541/essoar.174438106.63564767/v1). This study used the Soil and Water Assessment Tool (SWAT), a processed based model to explore the impacts of area burned and burn severity on streamflow, nitrate, and dissolved organic carbon (DOC) in two test basins: a semi-arid, mixed land use basin and a humid, primarily forested basin. We developed 1800 wildfire scenarios that we ran in each basin: 20 different burn extents (5 to 100% by 5%), 3 different burn severities (low, moderate, and high), and 30 different post-fire precipitation scenarios. We also ran an additional 30 scenarios associated with no wildfire for the 30 post-fire precipitation scenarios. For each scenario we were interested in the change in runoff ratio (streamflow) and average concentration and annual loads (nitrate and DOC) across the wildfire scenarios. This data package contains the data and scripts required to build SWAT models for the two test basins, create and run the wildfire scenarios, and generate the data summaries and figures used in the associated manuscript. This data package was originally published in March 2025. It was updated in January 2026 (v2; new and modified files) to include the final files after the manuscript went through reviews. See the change history section below for more details. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About.

54 ENVIRONMENTAL SCIENCES↗

Observed humidity trends in dry regions contradict climate models

Arid and semi-arid regions of the world are particularly vulnerable to greenhouse gas–driven hydroclimate change. Climate models are our primary tool for projecting the future hydroclimate that society in these regions must adapt to, but here, we present a concerning discrepancy between observed and model-based historical hydroclimate trends. Over the arid/semi-arid regions of the world, the predominant signal in all model simulations is an increase in atmospheric water vapor, on average, over the last four decades, in association with the increased water vapor–holding capacity of a warmer atmosphere. In observations, this increase in atmospheric water vapor has not happened, suggesting that the availability of moisture to satisfy the increased atmospheric demand is lower in reality than in models in arid/semi-arid regions. This discrepancy is most clear in locations that are arid/semi-arid year round, but it is also apparent in more humid regions during the most arid months of the year. Here, it indicates a major gap in our understanding and modeling capabilities which could have severe implications for hydroclimate projections, including fire hazard, moving forward.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

North Dakota Integrated Carbon Storage Complex Feasibility Study. Final report

In spring 2017, the Energy & Environmental Research Center (EERC) initiated an effort to determine the feasibility of developing a commercial-scale CO 2 geologic storage complex able to store 50+ million tonnes (Mt) of CO 2 in central North Dakota safely, permanently, and economically. The objective was to fulfill the goals of the U.S. Department of Energy (DOE) Carbon Storage Assurance Facility Enterprise (CarbonSAFE) Initiative and address technical and nontechnical challenges specific to commercial-scale deployment of a CO2 storage project. The findings clearly show that the concept of capturing CO 2 from a lignite-fired electrical generation facility in central North Dakota and safely and permanently storing the CO 2 in the deep subsurface is indeed technically, economically, and socially feasible. This project evaluated two study areas and their respective geologic storage complexes located adjacent to separate coal-fired facilities in North Dakota: the Basin Electric Power Cooperative (BEPC)-owned Great Plains Synfuels Plant (GPSP) and the Minnkota Power Cooperative (Minnkota)-owned Milton R. Young Station (MRYS). These locations, one with CO 2 capture in place and an existing CO 2 pipeline, are bolstered by progressive North Dakota pore space ownership and long-term liability laws. These elements and a motivated team created an ideal synergistic scenario for ensuring success of the CarbonSAFE Initiative and promoting North Dakota’s statewide vision for carbon management. The project included drilling two new geologic characterization wells, integrating an existing 3-D seismic survey, creating a geologic model subsequently used for injection simulation, a risk assessment, public outreach, and generating a site development plan based on results. In addition, the performance of select National Risk Assessment Partnership tools was evaluated. The geologic characterization wells were drilled ~5600 feet deep to the Broom Creek Formation; ~350 feet of core was retrieved from each well. The core included the Broom Creek (targeted injection zone) and a portion of the overlying Opeche Shale (seal). The Flemmer-1 well, west of Beulah, North Dakota, yielded 169 feet of sandstone. The BNI-1 well located south of Center, North Dakota, yielded 124 feet of sandstone. In each case, laboratory analysis of the sandstone showed permeability in the 300–1000-mD range, with porosity of 20%–30%. The Flemmer-1 well was sited within the boundaries of an existing 3-D seismic survey. Colocating the well with the seismic survey maximized the relationship between new and legacy data and developed a first-of-its-kind interpretation of the geologic fabric of the Broom Creek. Geologic characterization data were integrated into a 5544-mi 2 geocellular model that encompassed both new wells and stratigraphy from the surface to the Amsden Formation (underlying the Broom Creek). The model was later expanded vertically to include the deeper Black Island–Deadwood interval to examine its potential viability as a storage target. The geocellular model provided the foundation for dynamic simulation of CO 2 into the Broom Creek. Results of the simulation suggest that the Broom Creek could accept the DOE target rate of 2 Mt/yr of CO 2 into as few as two wells. To bracket the expected capture from MRYS, simulations were also investigated for a 4-Mt/yr rate near MRYS. Although more wells are needed (two additional), the Broom Creek still has the storage resource to accept the CO 2 at the increased rate. A risk assessment exercise was conducted to identify and assess technical and nontechnical risks that could prevent potential candidate storage complexes within the study area from serving as commercial storage sites. The assessment identified and evaluated six technical risk categories: 1) CO 2 injectivity, 2) storage capacity, 3) lateral migration of CO 2 , 4) lateral pressure propagation, 5) vertical migration of CO 2 or formation brine, and 6) induced seismicity. Following two rounds of analysis and scoring, no risks were determined to preclude continued efforts to develop carbon capture, utilization, and storage (CCUS) in central North Dakota. The risk assessment results will be used to guide future site characterization, modeling and simulation, and monitoring activities. A specific nontechnical strategic risk based on challenges that may be realized in amalgamation of pore space resulted in vertically expanding the geologic model to incorporate the potential for stacked storage in multiple saline reservoirs. By including the Black Island–Deadwood interval (the basal sedimentary reservoir in this region), the amalgamated areal extent could be reduced by as much as 45%. Working with a smaller geographic area reduces risks and costs associated with monitoring and pore space leasing. An economic evaluation incorporating capture; transport (<5 mi); Class VI wells; permitting; and monitoring, verification, and accounting suggests implementing commercial-scale CCUS is economically attractive if the federal tax benefits of 45Q are included. This is validated by Minnkota’s continued pursuit of CO 2 capture and geologic storage at MRYS through its Project Tundra initiative, indicating that there is a business case for CCUS in central North Dakota. Currently, North Dakota is the only state with underground injection control (UIC) Class VI primacy. Built into the North Dakota Century Code is a series of regulatory requirements that guide the process to obtain a Class VI CO 2 storage facility permit. As part of this project, a site development plan was compiled to assure compliance with North Dakota’s requirements to permit a commercial-scale CO 2 storage operation and includes a prospective time line encompassing a general breakdown of activities. In total, an estimated 30 months would be needed to execute the necessary steps to attain a North Dakota CO 2 storage facility permit. Outreach was an integral part of the project and encompassed any project-related activity that had contact or exposure beyond the project team. The goals of outreach were to foster an environment from which stakeholders could make informed decisions about the project and gauge community receptiveness to a CCUS project. A consistent set of messages and outreach products were developed in conjunction with an outreach advisory board that integrated project partners and team members. To gauge public acceptability of geologically storing CO 2 , 5611 households in the project area were invited to participate in an online survey. The survey results indicate that the public attitude regarding CCUS is neutral to positive, with strong sentiment that CO 2 capture and storage may be an approach to maintain the economic vitality of the region. To achieve project objectives, critical support in the form of financial backing, engineering evaluations, site access, outreach collaboration, operations data, risk assessment/evaluation, and software access was provided by BEPC, the North Dakota Industrial Commission Lignite Research Council, ALLETE Clean Energy, BNI Energy, North American Coal Corporation, Minnkota, Prairie Public Broadcasting, Computer Modelling Group Ltd., and Schlumberger.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Synchronization properties of coupled chaotic neurons: The role of random shared input

Spike-time correlations of neighbouring neurons depend on their intrinsic firing properties as well as on the inputs they share. Studies have shown that periodically firing neurons, when subjected to random shared input, exhibit asynchronicity. Here, we study the effect of random shared input on the synchronization of weakly coupled chaotic neurons. The cases of so-called electrical and chemical coupling are both considered, and we observe a wide range of synchronization behaviour. When subjected to identical shared random input, there is a decrease in the threshold coupling strength needed for chaotic neurons to synchronize in-phase. The system also supports lag–synchronous states, and for these, we find that shared input can cause desynchronization. We carry out a master stability function analysis for a network of such neurons and show agreement with the numerical simulations. The contrasting role of shared random input for complete and lag synchronized neurons is useful in understanding spike-time correlations observed in many areas of the brain.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Degradation and deforestation increase the sensitivity of the Amazon Forest to climate extremes

About 40% of the Brazilian Amazon has been deforested or suffered changes in forest structure through degradation (selective logging, fires, and fragmentation). The impact of forest degradation on the forest’s sensitivity to climate extremes has not been fully explored because of a lack of data and the complex interplay of forest structure and climate drivers. Here, we combined forest structure data from 545 airborne lidar transects (375 ha each) across the Brazilian Amazon with the Ecosystem Demography Model (ED2). We explore the forest’s functional response to near-present (1981–2019) climate extremes under observed forest structure from lidar ( Control ) and two forest structure change scenarios: (1) forest recovery by excluding all future deforestation and degradation ( Recovery ) and (2) expansion of selective logging and deforestation ( Degradation ). Using the Control simulation, we found a close and positive association between local forest aboveground biomass and the predicted gross primary productivity (GPP) and evapotranspiration (ET). Moreover, both GPP and ET respond negatively to extremes in vapor pressure deficit and downwelling shortwave irradiance in degraded forests in Eastern and Southern Amazon, indicating high sensitivity to droughts. Locally high-biomass forest patches showed little or no negative response of GPP and ET to extreme drought conditions whereas low-biomass forest patches in the same locations—typically degraded forest canopies—responded negatively to higher moisture stress. The results from the Recovery scenario showed similar results to simulations with observed structure; however, under the Degradation scenario, low-biomass forest patches became more abundant, resulting in more regions where GPP and ET are negatively impacted by hot drought conditions according to the ED2 model. Our results suggest that local forest structure is a critical determinant of an ecosystem’s response to climate variability, and that the loss of canopy trees in the Amazon through forest degradation could increase and expand forest vulnerability to droughts.

54 ENVIRONMENTAL SCIENCES↗

Development of Extended Period Pressure-Dependent Demand Water Distribution Models

Los Alamos National Laboratory (LANL) has used modeling and simulation of water distribution systems for N-1 contingency analyses to assess criticality of water system assets. Critical components considered in these analyses include pumps, tanks, and supply sources, in addition to critical pipes or aqueducts. A contingency represents the complete removal of the asset from system operation. For each contingency, an extended period simulation (EPS) is run using EPANET. An EPS simulates water system behavior over a time period, typically at least 24 hours. It assesses the ability of a system to respond and recover from asset disruption through distributed storage in tanks throughout the system. Contingencies of concern are identified as those in which some portion of the water system has unmet delivery requirements. A delivery requirement is defined as an aggregation of water demands within a service area, similar to an electric power demand. The metric used to identify areas of unmet delivery requirement in these studies is a pressure threshold of 15 pounds per square inch (psi). This pressure threshold is used because it is below the required pressure for fire protection. Any location in the model with pressure that drops below this threshold at any time during an EPS is considered to have unmet service requirements and is used to determine cascading consequences. The outage area for a contingency is the aggregation of all service areas with a pressure below the threshold at any time during the EPS.

42 ENGINEERING↗

Detecting Short Circuits: Post Accident Electric Vehicle Battery Safety Check

Fast and accurate detection of soft short circuits (SCs) in the battery packs of damaged electric vehicles is needed by first responders and mechanics to mitigate the potential risk from battery fires that may occur hours, days, or weeks after an accident. Here, this paper presents an SC-detection algorithm for potentially damaged lithium-ion batteries that works quickly and without a priori knowledge of the battery-pack chemistry, capacity, state of charge, or state of health. The proposed universal SC-detection algorithm is designed to be implemented on an inexpensive handheld device that can connect to and monitor the voltages of all cells in a pack. Transient filtering and linear-quadratic state observation provide estimates of normalized SC current for every cell in the pack. Cells with SC-current estimates outside a sigma-based threshold are detected. Simulations, experiments, and electric vehicle (EV) crash data are used to verify the speed, sensitivity, and accuracy of the method, demonstrating 96% accurate detection of 0.0027 C SCs in under 1 h for 5S cell groups in the lab and no false positives for crashed Volkswagen, Chevrolet, and Tesla vehicles without SCs.

25 - ENERGY STORAGE↗

Comparison of passivation properties of plasma-assisted ALD and APCVD deposited Al 2 O 3 with SiN x capping

In this paper, we report on the direct comparison of Al 2 O 3 films deposited by plasma-assisted atomic layer deposition (ALD) and atmospheric pressure chemical vapor deposition (APCVD) techniques on the passivation properties of both bare and boron diffused Si surfaces. It is found that ALD and APCVD deposited Al 2 O 3 layers with SiN x capping have very similar chemical composition, hydrogen concentration at the Al 2 O 3 /Si interface, and interface defect density (D it ), but the ALD film has slightly higher negative fixed charge (Q f ) after a high temperature (~750 °C) contact firing cycle typically used for solar cell fabrication. Both films showed excellent surface recombination velocities of <5 cm/s on planar and textured un-diffused Si wafers, but the ALD films gave 1 to 8 fA/cm 2 lower emitter saturation current densities (J 0e ) on implanted boron emitters with sheet resistance in the range of 90–180 Ω/. This is attributed to the observed slightly higher negative charge-induced field-effect passivation in the ALD films. However, SiN x /Al 2 O 3 /p + /n/n + passivated emitter rear totally diffused (PERT) cell structures fabricated with 110 and 150 Ω/ emitter in this study showed no appreciable difference in cell efficiency. Device analysis and simulations showed that even for >23% high-performance solar cells design, with very low bulk and rear contact recombination, the observed small difference in J 0e has negligible effect on cell efficiency. Furthermore, APCVD Al 2 O 3 passivation of B emitter can produce comparable efficiencies to their counterpart ALD Al 2 O 3 passivated n-type Si solar cells.

14 SOLAR ENERGY↗

Low cost back contact heterojunction solar cells on thin c-Si wafers. integrating laser and thin film processing for improved manufacturability

An interdigitated back contact (IBC) Si wafer solar cell with deposited a-Si heterojunction (HJ) emitter and contacts is considered the ultimate single junction Si solar cell design. This was confirmed in 2014 by both Panasonic and Sharp Solar producing IBC-HJ cells breaking the previous record Si solar cell efficiency of 25%. But manufacturability at low cost is a concern for the complex IBC-HJ device structure. In this research program, our goals were to addressed the broad industry need for a high-efficiency c-Si cell that overcomes the dominant module cost barriers by 1) developing thin Si wafers synthesized by innovative, kerfless techniques; 2) integrating laser-based processing into most aspects of solar cell fabrication, ensuring high speed and low thermal budgets ; 3) developing an all back contact cell structure compatible with thin wafers using a simplified, low-temperature fabrication process; and 4) designing the contact patterning to enable simplified module assembly. There were a number of significant achievements from this 3 year program. Regarding the front surface, we developed and applied new method to characterize critical interface recombination parameters including interface defect density Dit and hole and electron capture cross-section for use as input for 2D simulation of the IBC cell to guide design and loss analysis. We optimized the antireflection and passivation properties of the front surface texture and a-Si/a-SiN/a-SiC stack depositions to obtain a very low (< 6 mA/cm2) front surface optical losses (reflection and absorption) while maintaining excellent surface passivation (SRV<5 cm/s). We worked with kerfless wafer manufacturers to apply defect-engineering techniques to improve bulk minority-carrier lifetime of thin kerfless wafers by both reducing initial impurities during growth and developing post-growth gettering techniques. This led insights about the kinetics of nickel, chromium, and dislocations in PV-grade silicon and to achieving millisecond lifetimes in kerfless silicon materials. Laser fired contacts to n-Si were developed for the first time using a Al/Sb/Ti metal stack giving contact resistances < 5 mOhm-cm2 when fired through several different dielectric layers. A new 2 step laser+chemical etch isolation technique was developed using a sacrificial top coating which avoids laser damage to Si passivation. Regarding the heterojunction emitter, analysis of front FHJ (1D) and IBC (2D) cells with range of p-layer conditions found that a 2-stage high/low doped p-layer was optimum: the low doped region has lower defects giving higher Voc and the high doped region gave a better contact to the metal. A significant effort was spent studying the patterning process and its contribution to degradation of passivation and reproducibility. Several promising new cleaning, contact and deposition patterning and processing approaches were implemented leading to fabrication of several runs with cells having 19-20% efficiency which were stable over several months. This program resulted in the training and support of 12 graduate students, publication of 21 journal papers and 14 conference papers.

14 SOLAR ENERGY↗

Cybersecurity for Distance Relay Protection

This project is a DOE follow-up effort on the CREDC workshop held on September 13, 2018 in Cambridge, MA to discuss cybersecurity of distance relays, which considered the benefits, vulnerabilities and risk mitigations for the use of communication systems in power system protection. The objectives of this project are to define the taxonomy of relay protection and associated communications; define use cases describing approaches to reduce the cyber-attack surface on those protective relays; and evaluate the loss of operational functional capability from changes to communication coverage. Mitigating controls will also be evaluated to understand if there are other approaches to reduce attack surfaces while maintaining communications or partial communications. Distance relays are used to protect transmission lines of approximately 10 to 300 miles in length, by detecting short circuits (i.e., faults) on the lines and then tripping circuit breakers in the substation. Such protection systems are a subset of the power system and they incorporate sensing, logic and communication functions. Protection system exposure to cyberattack could be drastically limited by disconnecting relays from all vulnerable communication systems, but this may adversely impact overall power system performance in the absence of cyberattack. This project began with a use case analysis of protection systems with communications, as summarized in this report. It continued with modeling, testing and evaluation in a miniature power system (MPS), located in the Western Area Power Administration (WAPA) Electric Power Training Center (EPTC). The project also incorporated feedback from two industry meetings held in February and September 2019. The suggested next steps account for and complement the work already underway with DOE/CESER funding: 1. Study the performance of LCD and PC vs. PUTT, which is less reliant on communication system performance and GPS timing references. The PUTT scheme could prove to be more resilient to cyberattack or communications-related disruption. It could also be more tolerant of message re-routing with SDN/SDR communication systems. On the other hand, it will be more vulnerable to false tripping during dynamic events or to loss of the voltage signal. The optimum choice of scheme may depend on the specific power system and risk assessment. This study could provide a new template for evaluation based on business functions. 2. Research and develop new methods to detect and monitor distributed physical attacks, possibly using drones, video sensors, thermal sensors, machine learning and other advanced techniques. This will help mitigate the impact of cyberattack on the protection system, and will also help mitigate the impact of wild fires. 3. Implement a scalable PKI for use in electric utility protection systems. This will encourage widespread adoption of secure authentication methods that are already available, but not widely used at present. This will help secure engineering access to the relays. 4. Investigate the use of SDN in combination with SDR to achieve better cybersecurity and electromagnetic security of the network, incorporating path variability. This would help secure both engineering access and peer-to-peer GOOSE messaging. 5. Perform additional testing, with operator evaluation of “red button” scenarios, PUTT vs. LCD, relay mis-operations, and other cyberattacks in the EPTC. This is an important advantage of testing in the EPTC rather than by computer simulation or even hardware-in-the-loop simulation; the EPTC is already dedicated to managing the situational awareness, operator response times and other human impacts. One of the project objectives was to settle on a common nomenclature for this problem space. We have concluded that the OSI layer model, supplemented by ANSI device numbers and other IEEE standards, is already well-accepted by the industry. The IEEE PSRC knowledge base provides a great deal of public information

24 POWER TRANSMISSION AND DISTRIBUTION↗

Molecular characterization of free tropospheric aerosol collected at the Pico Mountain Observatory: a case study with a long-range transported biomass burning plume

Free tropospheric aerosol was sampled at the Pico Mountain Observatory located at 2225 m above mean sea level on Pico Island of the Azores archipelago in the North Atlantic. The observatory is located ~ 3900 km east and downwind of North America, which enables studies of free tropospheric air transported over long distances. Aerosol samples collected on filters from June to October 2012 were analyzed to characterize organic carbon, elemental carbon, and inorganic ions. The average ambient concentration of aerosol was 0.9 ± 0.7 μg m -3 . On average, organic aerosol components represent the largest mass fraction of the total measured aerosol (60 ± 51%), followed by sulfate (23 ± 28%), nitrate (13 ± 10%), chloride (2 ± 3%), and elemental carbon (2 ± 2%). Water-soluble organic matter (WSOM) extracted from two aerosol samples (9/24 and 9/25) collected consecutively during a pollution event were analyzed using ultrahigh-resolution electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry. Approximately 4000 molecular formulas were assigned to each of the mass spectra in the range of m/z 100–1000. The majority of the assigned molecular formulas had unsaturated structures with CHO and CHNO elemental compositions. FLEXPART retroplume analyses showed the sampled air masses were very aged (average plume age > 12 days). These aged aerosol WSOM compounds had an average O/C ratio of ~ 0.45, which is relatively low compared to O/C ratios of other aged aerosol. The increase in aerosol loading during the measurement period of 9/24 was linked to biomass burning emissions from North America by FLEXPART retroplume analysis and Moderate Resolution Imaging Spectroradiometer (MODIS) fire counts. This was confirmed with biomass burning markers detected in the WSOM and with the morphology and mixing state of particles as determined by scanning electron microscopy. The presence of markers characteristic of aqueous-phase reactions of phenolic species suggests that the aerosol collected at the Pico Mountain Observatory had undergone cloud processing before reaching the site. Finally, the air masses of 9/25 were more aged and influenced by marine emissions, as indicated by the presence of organosulfates and other species characteristic of marine aerosol. The change in the air masses for the two samples was corroborated by the changes in ethane, propane, and ozone, morphology of particles, as well as by the FLEXPART retroplume simulations. This paper presents the first detailed molecular characterization of free tropospheric aged aerosol intercepted at a lower free troposphere remote location and provides evidence of low oxygenation after long-range transport. We hypothesize this is a result of the selective removal of highly aged and polar species during long-range transport, because the aerosol underwent a combination of atmospheric processes during transport facilitating aqueous-phase removal (e.g., clouds processing) and fragmentation (e.g., photolysis) of components.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗