Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flammability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Mechanistic study of chemical looping reactions between solid carbon fuels and CuO

Copper (Cu) based chemical-looping combustion (CLC) is a promising process that utilizes solid carbon fuel such as coal and biomass. Understanding the reaction kinetics in this process can facilitate the industrial design of CLC units. Here, in this work, molecular dynamics (MD) simulations were performed to investigate the reaction kinetics of n-butane and two simplified solid carbon fuels (lignite and anthracite) with/without copper oxide (CuO) nanoparticle. In addition, experiments were conducted on the thermal characteristics, flammability, and flame speeds of CuO and solid carbon mixtures. For n-butane, oxidation on the CuO surface is the primary reaction since the activation energy of the surface reaction is much lower than that of oxygen (O 2 ) combustion (9.2 vs. 53.3 kcal/mol). On the other hand, for lignite, there is a smaller difference in the activation energy of O 2 combustion and surface reaction (23.04 vs. 6.34 kcal/mol). We hypothesize that some solid carbon fuels can have different reaction kinetics dependent upon temperature. This is proven by the case of a simplified anthracite coal: an Arrhenius plot shows that this solid carbon fuel has two different reaction kinetic regimes and the critical temperature for the change in kinetics is related to the oxygen uncoupling of the CuO nanoparticle. Like the modeling simulations, a change in activation energy is observed in the experimental results, where desorption of molecular oxygen from CuO becomes important.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simulations of flaming combustion and flaming-to-smoldering transition in wildland fire spread at flame scale

Our objective in the present study is to provide basic insights into the coupling between external-gas and solid biomass vegetation processes that control the dynamics of flame spread in wildland fire problems. Here we focus on a modeling approach that resolves processes occurring at vegetation and flame scales, i.e., the formation of flammable vapors due to the thermal degradation of the solid biomass, the subsequent combustion in ambient air, the thermal feedback to the biomass through radiative and convective heat transfer, and the possible transition from flaming combustion (taking place outside of the solid biomass) to smoldering combustion (taking place inside the solid biomass). The capability uses a multiphase combustion framework and treats external-gas processes through a Large Eddy Simulation solver and solid biomass processes through a discrete particle model. The discrete particle model adopts a one-dimensional porous medium formulation, includes descriptions of drying, thermal pyrolysis, oxidative pyrolysis, and char oxidation, as well as a description of the external-gas-to-solid-biomass diffusion of oxygen mass; the discrete particle model thereby provides a treatment of in-depth oxidative processes and allows the simulation of smoldering combustion. The modeling capability is applied to the simulation of fire spread across a surrogate biomass vegetation bed corresponding to a discrete array of cylindrical-shaped, vertically-oriented, pine wood sticks, characterized by a monomodal size distribution, in horizontal flat terrain and under wind-aided conditions. The numerical results demonstrate that the model can simulate successful flaming-to-smoldering transition followed by complete biomass consumption.

01 COAL, LIGNITE, AND PEAT↗

Garnet-rich composite solid electrolytes for dendrite-free, high-rate, solid-state lithium-metal batteries

Composite solid electrolytes (CSEs), which are composed of inorganic fillers and organic polymers, show improved safety and suppressed lithium dendrite growth in Li-metal batteries, as compared to flammable liquid electrolytes. However, the performance of current CSEs is limited by the agglomeration effect, with low content of inorganic Li + -conducting fillers and ineffective Li + transport between the inorganic fillers and the polymer matrix. To address these challenges, a new type of CSE composed of silane-modified Li 6.28 La 3 Al 0.24 Zr 2 O 12 (s@LLAZO) nanofibers and poly(ethylene glycol) diacrylate (PEGDA) is developed. Employment of the silane coupling agent, 3-(trimethoxysilyl)propyl methacrylate, enables the incorporation of a high content of LLAZO nanofibers (up to 70 wt%) with the polymer matrix and results in a well-percolated, three-dimensional LLAZO network fully embedded in the PEGDA matrix. Consequently, the silane coupling agent successfully eliminates the agglomeration effect, which ensures higher ionic conductivity, larger lithium transference number, wider electrochemical stability window, and better cycling stability for s@LLZAO-PEGDA CSEs. Excellent cycling stability and extraordinarily high rate capability (up to 10C) are demonstrated in the all-solid-state Li-metal batteries with LiFePO 4 and high-voltage Li[Ni 1/3 Mn 1/3 Co 1/3 ]O 2 cathodes at ambient temperature. This novel design of CSEs with s@LLAZO nanofibers paves the way for a new generation of improved functioning all-solid-state Li-metal batteries.

25 ENERGY STORAGE↗

The role of ionic liquids in resolving the interfacial chemistry for (quasi-) solid-state batteries

Interfacial issues impede the advancement of current solid state battery technology; thus, interface engineering approaches are necessary to enable solid-state configuration. The advantage of solid-state cells stems from their low flammability and high electrochemical stability. Ionic liquids are viscous and nonflammable compounds that possess the requisite physical properties while optimizing the interface between solid electrodes and solid electrolytes, accelerating interfacial ion transport and enabling the fabrication of engineered interphases via the supply of robust chemical building blocks. In conclusion, this review summarizes the roles of ionic liquids in solid-state batteries focusing on the interface, with insights into their functionality as well as highlighting their applicability in the next generation battery systems.

25 ENERGY STORAGE↗

Characterizing Hazardous Gases from NMC811 Materials and Coin Cells with TGA and Tube-Furnace FTIR-MS Evolved-Gas-Analysis

Abuse testing is useful for informing the risks of different battery chemistries but has been limited to larger formats. This paper conducted thermal abuse tests at the smaller coin cell level to determine its relevance in specifying vent gas flammability and toxicity. A nitrogen purge carried the evolved gases into a parallel Fourier-transform infrared spectrometer (FTIR) and a mass spectrometer (MS) downstream of the tube furnace. The experimental system was validated by comparing evolved gas data for single components between the tube furnace system and a thermogravimetric analysis (TGA) instrument. Multiple samples were tested during validation, including CaCO3, electrolyte, delithiated NMC 811 cathode, and lithiated graphite anode. Temperature-resolved gas evolution of HF, CO2, CO, H2, and hydrocarbons from isolated components helped to characterize the emission sources. A previously unreported H2 generation mechanism was found. It was shown that the reduced NMC cathode acts as a catalyst to crack polypropylene-decomposed hydrocarbons into H2 at around 450 degrees C. It was also shown, while studying LiPF6 thermal decomposition, that using the tube furnace with a coin cell casing as the sample holder has some advantages for evolved-gas analysis of environmentally sensitive samples relative to testing in TGA instruments. After validation with single components, a fully charged NMC 811 coin cell was failed in the tube furnace. The measured evolved gases were found to be a combination of the species measured from the single component tests. H2 formation related to the reduced cathode was found to have greater abundance than H2 formed from the anode. Hydrogen fluoride emission factors and diethyl carbonate conversion emission factors assist in understanding the gaseous hazards for larger format cells.

25 ENERGY STORAGE↗

Safety perceptions of solid-state lithium metal batteries

Safety concerns hamper the wide application of lithium-ion batteries (LIBs) in the fields of electric vehicles and stationary energy storage. As the blame of the battery thermal runway was widely cast on the flowable, volatile, and flammable nature of liquid organic electrolytes, solid-state lithium batteries with solid and nonflammable electrolytes are highly praised for potentially better safety characteristics. Furthermore, solid-state lithium metal batteries (SS-LMBs) may become an ultimate solution for safe, high-energy density batteries. Whether SS-LMBs are safe enough to meet emerging demands remains unclear, as recent publications have presented serious safety concerns at both the material and device levels. In conclusion, this review summarizes recent investigations into SS-LMB safety, and systematic analysis and discussion are provided in this discussion of the safety concerns of SS-LMBs.

25 ENERGY STORAGE↗

Evaluating fuel complexes for fire hazard mitigation planning in the southeastern United States.

Fire hazard mitigation planning requires an accurate accounting of fuel complexes to predict potential fire behavior and effects of treatment alternatives. In the southeastern United States, rapid vegetation growth coupled with complex land use history and forest management options requires a dynamic approach to fuel characterization. In this study we assessed potential surface fire behavior with the Fuel Characteristic Classification System (FCCS), a tool which uses inventoried fuelbed inputs to predict fire behavior. Using inventory data from 629 plots established in the upper Atlantic Coastal Plain, South Carolina, we constructed FCCS fuelbeds representing median fuel characteristics by major forest type and age class. With a dry fuel moisture scenario and 6.4 km h{sub 1} midflame wind speed, the FCCS predicted moderate to high potential fire hazard for the majority of the fuelbeds under study. To explore fire hazard under potential future fuel conditions, we developed fuelbeds representing the range of quantitative inventorydata for fuelbed components that drive surface fire behavior algorithms and adjusted shrub species composition to represent 30% and 60% relative cover of highly flammable shrub species. Results indicate that the primary drivers of surface fire behavior vary by forest type, age and surface fire behavior rating. Litter tends to be a primary or secondary driver in most forest types. In comparison to other surface fire contributors, reducing shrub loading results in reduced flame lengths most consistently across forest types. FCCS fuelbeds and the results from this project can be used for fire hazard mitigation planning throughout the southern Atlantic Coastal Plain where similar forest types occur. The approach of building simulated fuelbeds across the range of available surface fuel data produces sets of incrementally different fuel characteristics that can be applied to any dynamic forest types in which surface fuel conditions change rapidly.

54 ENVIRONMENTAL SCIENCES↗

Neutronics and activation analysis of lithium-based ternary alloys in IFE blankets

Here we report that an attractive feature of using liquid lithium as the breeder and coolant in fusion blankets is that it has very high tritium solubility and results in very low levels of tritium permeation throughout the facility infrastructure. However, lithium metal vigorously reacts with air and water and presents plant safety concerns. The Lawrence Livermore National Laboratory is carrying an effort to develop a lithium-based alloy that maintains the beneficial properties of lithium (e.g. high tritium breeding and solubility) and at the same time reduces overall flammability concerns. This study evaluates the neutronics performance of lithium-based alloys in the blanket of an inertial fusion energy chamber in order to inform such development. 3-D Monte Carlo calculations were performed to evaluate two main neutronics performance parameters for the blanket: tritium breeding ratio (TBR), and the fusion energy multiplication factor (EMF). It was found that elements that exhibit low absorption cross sections and higher q-values such as lead, tin, and strontium, perform well with those that have high neutron multiplication such as lead and bismuth. These elements meet TBR constrains ranging from 1.02 to 1.1. However, most alloys do not reach EMFs greater than 1.15. Additionally, it was found that enriching lithium significantly increases the TBR and decreases the minimum lithium concentration by more than 60%. The amount of enrichment depends on how much total lithium is in the alloy to begin with. Alloys that performed well in the TBR and EMF calculations were considered for activation analysis. Activation simulations were executed with 50 years of irradiation and 300 years of cooling. It was discovered that bismuth is a poor choice due to achieving the highest decay heat, contact dose rates, and accident doses. In addition, it does not meet the waste disposal ratings (WDR). Some of the activation results for alloys with tin, zinc, and gallium were in the higher end and should be considered secondary to elements such as strontium and barium that had overall better results. The results of this study along with other considerations such as thermodynamics, and chemical reactivity will help down select a preferred lithium ternary alloy.

36 MATERIALS SCIENCE↗

Designing slippery rough surfaces to enhance dropwise condensation of low surface tension fluid

Enhancing low surface tension liquid condensation is critical for achieving high energy efficiency and reducing the size of thermal energy systems. Extensive research has focused on promoting dropwise condensation of these liquids using state-of-the-art coatings on plain surfaces. However, maintaining dropwise condensation with low surface tension fluids is challenging due to rivulet formation, resulting in wetted tails that transition to filmwise condensation at elevated heat fluxes. Here, to address this issue, we uncover the role of surface structures and surface chemistry in the dropwise condensation of low surface tension ethanol on slippery rough surfaces (SRS). High-performance dropwise condensation has been achieved on slippery microchannels grafted with perfluoropolyether. The SRS uniquely facilitates rapid lateral droplet removal, enabling faster directional droplet shedding without rivulet formation. The resulting higher droplet removal frequency on SRS leads to heat transfer coefficients 100 % and 500 % higher than conventional dropwise and filmwise condensation on plain surfaces, respectively. Our findings uncover the pivotal role of rapid droplet removal through slippery microchannels in sustaining dropwise condensation of low surface tension liquids. This study introduces a new paradigm for promoting dropwise condensation using engineered SRS that incorporates surface structure and surface chemistry. The work will provide fundamental design guidelines to design efficient and compact condensers that use costly or flammable low global warming potential refrigerants in future refrigeration systems.

Dropwise condensation↗

Comparison of the safety-related physical and combustion properties of liquid hydrogen and liquid natural gas in the context of the SF-BREEZE high-speed fuel-cell ferry

Here, we review liquid hydrogen (LH 2 ) as a maritime vessel fuel, from descriptions of its fundamental properties to its practical application and safety aspects, in the context of the San Francisco Bay Renewable Energy Electric Vessel with Zero Emissions (SF-BREEZE) high-speed fuel-cell ferry. Since marine regulations have been formulated to cover liquid natural gas (LNG) as a primary propulsion fuel, we frame our examination of LH 2 as a comparison to LNG, for both maritime use in general, and the SF-BREEZE in particular. Due to weaker attractions between molecules, LH 2 is colder than LNG, and evaporates more easily. We describe the consequences of these physical differences for the size and duration of spills of the two cryogenic fuels. The classical flammability ranges are reviewed, with a focus on how fuel buoyancy modifies these combustion limits. We examine the conditions for direct fuel explosion (detonation) and contrast them with initiation of normal (laminar) combustion. Direct fuel detonation is not a credible accident scenario for the SF-BREEZE. For both fuels, we review experiments and theory elucidating the deflagration to detonation transition (DDT). LH 2 fires have a shorter duration than energy-equivalent LNG fires, and produce significantly less thermal radiation. The thermal (infrared) radiation from hydrogen fires is also strongly absorbed by humidity in the air. Hydrogen permeability is not a leak issue for practical hydrogen plumbing. We describe the chemistry of hydrogen and methane at iron surfaces, clarifying their impact on steel-based hydrogen storage and transport materials. These physical, chemical and combustion properties are pulled together in a comparison of how a LH 2 or LNG pool fire on the Top Deck of the SF-BREEZE might influence the structural integrity of the aluminum deck. Neither pool fire scenario leads to net heating of the aluminum decking. Overall, LH 2 and LNG are very similar in their physical and combustion properties, thereby posing similar safety risks. For ships utilizing LH 2 or LNG, precautions are needed to avoid fuel leaks, minimize ignition sources, minimize confined spaces, provide ample ventilation for required confined spaces, and to monitor the enclosed spaces to ensure any fuel accumulation is detected far below the fuel/air mix threshold for any type of combustion.

08 HYDROGEN↗

Empirical profiling of cold hydrogen plumes formed from venting of LH 2 storage vessels

Liquid hydrogen (LH 2 ) storage is viewed as a viable approach to assure sufficient hydrogen capacity at commercial fuelling stations. Presently, LH 2 is produced at remote facilities and then transported to the end-use site by road vehicles (i.e., LH 2 tanker trucks). Venting of hydrogen to depressurize the transport storage tank is a routine part of the LH 2 delivery and site transfer process. The behavior of cold hydrogen plumes has not been well characterized because of the sparsity of empirical field data, which can lead to overly conservative safety requirements. Committee members of the National Fire Protection Association (NFPA) Standard 2 [1] formed the Hydrogen Storage Safety Task Group, which consists of hydrogen producers, safety experts, and computational fluid dynamics modellers, has identified the lack of understanding of hydrogen dispersion during LH 2 venting of storage vessels as a critical gap for establishing safety distances at LH 2 facilities, especially commercial hydrogen fuelling stations. To address this need, the National Renewable Energy Laboratory Sensor Laboratory, in collaboration with the NFPA Hydrogen Storage Task Group, developed a prototype Cold Hydrogen Plume Analyzer to empirically characterize the hydrogen plume formed during LH 2 storage tank venting. The prototype analyzer was field deployed during an actual LH 2 venting process. Critical findings included: hydrogen above the lower flammable limit (LFL) was detected as much as 2 m lower than the release point, which is not predicted by existing models; personal monitors detected hydrogen at ground level, although at levels below the LFL; a small but inconsistent correlation was found between oxygen depletion and the hydrogen concentration; a negligible to non-existent correlation was found between in-situ temperature measurements and the hydrogen concentration. The prototype analyzer is being upgraded for enhanced metrological capabilities, including improved real-time spatial and temporal profiling of hydrogen plumes and tracking of prevailing weather conditions. Additional deployments are planned to monitor plume behavior under different wind, humidity, and temperature conditions. The data will be shared with the Hydrogen Storage Task Group and ultimately will be used support theoretical models and code requirements prescribed in NFPA 2.

08 HYDROGEN↗

Dispersion of cryogenic hydrogen through high-aspect ratio nozzles

Liquid hydrogen is increasingly being used as a delivery and storage medium for stations that provide compressed gaseous hydrogen for fuel cell electric vehicles. In efforts to provide scientific justification for separation distances for liquid hydrogen infrastructure in fire codes, the dispersion characteristics of cryogenic hydrogen jets (50–64 K) from high aspect ratio nozzles have been measured at 3 and 5 bar abs stagnation pressures. These nozzles are more characteristic of unintended leaks, which would be expected to be cracks, rather than conventional round nozzles. Spontaneous Raman scattering was used to measure the concentration and temperature field along the major and minor axes. Within the field of interrogation, the axis-switching phenomena was not observed, but rather a self-similar Gaussian-profile flow regime similar to room temperature or cryogenic hydrogen releases through round nozzles. The concentration decay rate and half-widths for the planar cryogenic jets were found to be nominally equivalent to that of round nozzle cryogenic hydrogen jets indicating a similar flammable envelope. The results from these experiments will be used to validate models for cryogenic hydrogen dispersion that will be used for simulations of alternative scenarios and quantitative risk assessment.

08 HYDROGEN↗

Risk assessment and ventilation modeling for hydrogen releases in vehicle repair garages

The availability of repair garage infrastructure for hydrogen fuel cell vehicles is becoming increasingly important for future industry growth. Ventilation requirements for hydrogen fuel cell vehicles can affect both retrofitted and purpose-built repair garages and the costs associated with these requirements can be significant. A hazard and operability (HAZOP) study was performed to identify risk-significant scenarios related to light-duty hydrogen vehicles in a repair garage. Detailed simulations and modeling were performed using appropriate computational tools to estimate the location, behavior, and severity of hydrogen release based on key HAZOP scenarios. Here, this work compares current fire code requirements to an alternate ventilation strategy to further reduce potential hazardous conditions. Modeling shows that position, direction, and velocity of ventilation have a significant impact on the amount of instantaneous flammable mass in the domain.

08 HYDROGEN↗

Estimating the energy requirement for hydrogen production in proton exchange membrane electrolysis cells using rapid operando hydrogen crossover analysis

Hydrogen (H 2 ) crossover in proton exchange membrane water electrolyzers refers to the process by which hydrogen produced at the cathode traverses the membrane and mixes with the oxygen produced at the anode. This phenomenon reduces efficiency and may pose flammability hazards. In this work we present a method for quantifying the H 2 content of the anode exhaust gas using a gas chromatograph that is capable of sampling data every 2 min. Subsequent theory is presented to calculate the crossover flux, overall H 2 efficiency, and H 2 energy requirements. Results the effects of membrane thickness using Nafion TM N117 (178 um) and Nafion TM NR212 (51 um) membranes. Furthermore, it was found that thinner membranes lead to improved VI performance but exhibit higher crossover rates. Despite their increased crossover, leading to decreased hydrogen efficiency, the calculated required energy for NR212 membrane-electrode assemblies (MEAs) was significantly lower than that of N117 MEAs.

08 HYDROGEN↗

Water-Based Electrode Manufacturing and Direct Recycling of Lithium-Ion Battery Electrodes—A Green and Sustainable Manufacturing System

It is critical to develop a low-cost and environmentally friendly system to manufacture and recycle lithium-ion batteries (LIBs) as the demand on LIBs keeps increasing dramatically. Conventional LIB cathodes are manufactured using N-methyl-2-pyrrolidone as the solvent, which is expensive, highly toxic, flammable, and energy intensive to produce and recover. Ideally, a close-loop industrial supply chain should be built, in which the batteries are manufactured, market harvested, and recycled with minimal external toxic solvent through the whole system. This work demonstrates a green and more sustainable manufacturing method for LIBs where no hazardous organic solvent is used during electrode manufacturing and recycling. The electrodes fabricated via water-based processing demonstrate comparable rate performance and cycle life to the ones from conventional solvent-based processing. Utilization of a water-soluble binder enables recovering the cathode compound from spent electrodes using water, which is successfully regenerated to deliver comparable electrochemical performance to the pristine one.

25 ENERGY STORAGE↗

Rheology characterization of ionic liquids under high pressure and high temperature

Ionic liquids (ILs) are liquid salts that exist at or below ambient temperatures and are composed of ion pairs. They offer promising alternatives to toxic, hazardous, highly flammable, and volatile solvents in various applications such as solution preparation, dispersion, gel formation, composites, and polymer melts. ILs possess unique and interesting characteristics, including excellent chemical and thermal stability and low vapor pressures. Understanding the rheological properties of ILs is essential to optimizing IL performance. This paper presents a comparative analysis of the rheological properties of two ionic liquids, Nsingle bondHexylpyridinium tetrafluoroborate (HPyBF4) and Nsingle bondHexylpyridinium bromide (HPyBr), under different shear rates, temperatures, and pressures. Rheological measurements were performed under varying controlled pressure and temperature conditions. The experimental investigation covered a pressure range of 689–12,411 kPa [100–1800 psi] and a temperature range from room temperature up to 522 kelvin (K) [480°F]. The primary objective is to explore and compare the flow behavior and viscoelastic characteristics of HPyBF4 and HPyBr under high-pressure and high-temperature conditions. The experimental data showed that HPyBF4 and HPyBr exhibited shear-thinning behavior, and pressure had an insignificant effect on rheology compared to the temperature effect. Under the same testing conditions, HPyBr showed higher shear stress and viscosity than HPyBF4. This research significantly contributes to the improved understanding of the rheological behavior of these specific ionic liquids and their suitability for diverse industrial and scientific applications, particularly in high-pressure and high-temperature environments.

15 GEOTHERMAL ENERGY↗

Effects of cathode electrolyte interfacial (CEI) layer on long term cycling of all-solid-state thin-film batteries

All-solid-state lithium-ion batteries have the potential to not only push the current limits of energy density by utilizing Li metal, but also improve safety by avoiding flammable organic electrolyte. However, understanding the role of solid electrolyte – electrode interfaces will be critical to improve performance. In this paper, we conducted long term cycling on commercially available lithium cobalt oxide (LCO)/lithium phosphorus oxynitride (LiPON)/lithium (Li) cells at elevated temperature to investigate the interfacial phenomena that lead to capacity decay. STEM-EELS analysis of samples revealed a previously unreported disordered layer between the LCO cathode and LiPON electrolyte. This electrochemically inactive layer grew in thickness leading to loss of capacity and increase of interfacial resistance when cycled at 80 °C. Finally, the stabilization of this layer through interfacial engineering is crucial to improve the long term performance of thin-film batteries especially under thermal stress.

25 ENERGY STORAGE↗