Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Performance Storage Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Probabilistic Resource Adequacy Suite (PRAS)

The Probabilistic Resource Adequacy Suite (PRAS) provides an open-source, research-oriented collection of tools for analysing the resource adequacy of a bulk power system. The simulation methods offered support everything from classical convolution-based analytical techniques through to high-performance sequential Monte Carlo methods supporting multi-region composite reliability assessment, including simulation of energy-limited resources such as storage.

Stephen, Gord↗

Radiolysis Model Formulation for Integration with the Mixed Potential Model

The U.S. Department of Energy Office of Nuclear Energy (DOE-NE), Office of Fuel Cycle Technology has established the Used Fuel Disposition Campaign (UFDC) to conduct the research and development activities related to storage, transportation, and disposal of used nuclear fuel (UNF) and high-level radioactive waste. Within the UFDC, the components for a general system model of the degradation and subsequent transport of UNF is being developed to analyze the performance of disposal options [Sassani et al., 2012]. Two model components of the near-field part of the problem are the ANL Mixed Potential Model and the PNNL Radiolysis Model. This report is in response to the desire to integrate the two models as outlined in [Buck, E.C, J.L. Jerden, W.L. Ebert, R.S. Wittman, (2013) “Coupling the Mixed Potential and Radiolysis Models for Used Fuel Degradation,” FCRD-UFD-2013-000290, M3FT-PN0806058]

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

H2Fills™ [SWR-19-67]

H2FillS: Hydrogen Filling Simulation The Hydrogen Filling Simulation (H2FillS) software is a thermodynamic model designed to track and report on the transient change in hydrogen temperature, pressure, and mass flow when filling a fuel cell electric vehicle (FCEV). H2FillS simulates gas flow from the hydrogen station to the FCEV storage system. Using empirical fueling data sets, the model has been validated over a range of fueling conditions to match common light-duty FCEV fill profiles. Overall, it provides significant benefits to the light-duty fueling market and fill knowledge gaps of the interaction between a hydrogen station and an FCEV. Capabilities Use the comprehensive H2FillS model to: Safely design and operate a hydrogen fueling station Support code refinement with readily available data Develop system and operational improvements to reduce capital or operating costs at hydrogen stations or on-board FCEVs. How It Works H2FillS uses a "drag-and-drop" graphical user interface to simulate station and vehicle systems with preset parameters for common hydrogen station components as default values. When needed, users can define their own parameters to create their own station or vehicle components. Download H2FillS in Two Steps Read the terms of the end user software license agreement. Register to download the software. There are two versions of the model: A full-station model starts the simulation at high-pressure ground storage, runs through a dispenser, and ends at a vehicle storage system. A partial-station model starts at the dispenser breakaway and consists solely of the dispenser components and the vehicle storage system. H2FillS will automatically output fill performance data from the vehicle by tracking pressure and temperature throughout the fill. Users can input their own fill profiles into the model to run a variety of simulations.

Peters, Michael↗

Catalytic Removal of Oxygen Impurities from Pressurized Oxy-Combustion Flue Gas for the Production of High-Purity Carbon Dioxide

Flue gas purification is important for pressurized oxy-combustion systems to produce pure carbon dioxide (CO 2 ) streams ready for storage or utilization. A catalytic approach to removing oxygen (O 2 ) impurities from pressurized oxy-combustion flue gas via reduction with methane (CH 4 ) was investigated in this work. Two types of catalysts were studied: palladium (Pd)-based catalysts supported on titania (TiO 2 ) prepared by incipient wetness impregnation and cobalt–manganese (CoMn) composite catalysts prepared by coprecipitation. The performance of the catalysts was evaluated in a high-pressure–high-temperature, fixed-bed reactor at a pressure of 15 bar and a gas hourly space velocity of 30 000 h –1 (standard conditions), with a simulated feeding gas composed of 3 vol % O 2 , 1.5 vol % CH 4 , and CO 2 as the balance gas. Among the Pd catalysts, 5% Pd/TiO 2 achieved the maximum 86% O 2 removal at ≥350 °C. The CoMn oxide catalysts displayed comparable or better activities for O 2 reduction compared with the Pd catalysts. Among them, the Co 40 Mn 1 catalyst exhibited the best performance, able to reduce 99.9% of O 2 impurities at ~370 °C with negligible carbon monoxide (CO) formation (<10 ppmv). Both trivalent and divalent Co and Mn were detected on the catalyst surface, and the superior activity of Co 40 Mn 1 might be associated with the resultant disordered structure. Furthermore, the activity of the catalyst was not affected by the presence of a trace amount of nitric oxide (NO) gas contaminant. Results of this study provide the basis for scale-up studies in both the synthesis and performance of non-noble metal catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrical Energy Storage Data Submission Guidelines, Version 2

Energy storage technologies are positioned to play a substantial role in power delivery systems. They have the potential to serve as an effective new resource to maintain reliability and allow for increased penetration of renewable energy. However, because of their relative infancy, there is a lack of knowledge about how these resources truly operate over time. A data analysis can help ascertain the operational and performance characteristics of these emerging technologies. Rigorous testing and a data analysis are important for all stakeholders to ensure a safe, reliable system that performs predictably on a macro level. Standardizing testing and analysis approaches to verify the performance of energy storage devices, equipment, and systems when integrating them into the grid will improve the understanding and benefit of energy storage over time from technical and economic vantage points. Demonstrating the life-cycle value and capabilities of energy storage systems begins with the data that the provider supplies for the analysis. After a review of energy storage data received from several providers, some of these data have clearly shown to be inconsistent and incomplete, raising the question of their efficacy for a robust analysis. This report reviews and proposes general guidelines, such as sampling rates and data points, that providers must supply for a robust data analysis to take place. Consistent guidelines are the basis of a proper protocol and ensuing standards to (1) reduce the time that it takes for data to reach those who are providing the analysis; (2) allow them to better understand the energy storage installations; and (3) enable them to provide a high-quality analysis of the installations. The report is intended to serve as a starting point for what data points should be provided when monitoring. Readers are encouraged to use the guidance in the report to develop specifications for new systems, as well as enhance current efforts to ensure optimal storage performance. As battery technologies continue to advance and the industry expands, the report will be updated to remain current.

25 ENERGY STORAGE↗

OPALCO - Decatur Island Solar and Energy Storage Project: An Assessment of Battery Technical Performance

Orcas Power & Light Cooperative (OPALCO) is a member-owned, nonprofit cooperative utility that provides energy services to approximately 11,200 customers across 20 islands in San Juan County, Washington. OPALCO’s mostly hydroelectric power is generated by Bonneville Power Administration and delivered to the islands by submarine cables. In 2016, as part of the second round of funding from the Washington state Clean Energy Fund, OPALCO received a $1 million matching grant to support a project that deployed a 504-kW LG community photovoltaic (PV) system in combination with a 1 MW/2 MWh lithium-iron-phosphate battery energy storage system (BESS) on Decatur Island, Washington. The Decatur Island Substation is essential to ensuring reliable energy for the residents of the San Juan Islands as it is the point of interconnection with the mainland transmission system. The BESS, in combination with the community solar array, will deliver an innovative method to both defer the costly upgrade of the transmission system and allow for other high-value applications intended to benefit the utility and its customers. In 2018, Pacific Northwest National Laboratory (PNNL) completed a preliminary economic assessment for several identified use cases in collaboration with OPALCO. Between August 2021 and May 2022, extensive testing was conducted, and the results were used to assess the technical performance of the BESS subjected to actual field operations. Both reference performance and use case tests were performed: (a) Reference performance tests assess the general technical capabilities of the BESS, such as energy capacity, round-trip efficiency (RTE), ramp rate, and signal tracking capability. These are the first tests performed (baseline) and are repeated after use case tests (post cycle). A standardized U.S. Department of Energy (DOE) energy storage performance protocol was used to characterize the BESS, including representative duty cycle profiles, test procedure guidance, and calculation guidance for determining key characteristics. (b) Use case tests examine the performance of the BESS for specific use cases using duty cycles developed by PNNL in collaboration with OPALCO. Four use cases were selected for testing: 1) demand charge reduction, 2) load shaping, 3) outage mitigation, and 4) transmission deferral. The use case duty cycles were developed based on utility and site-specific characteristics in addition to the technical characteristics and physical capabilities of the BESS. Use case tests were performed between the baseline and post cycle tests. This report describes the BESS and its components, presents testing and performance analysis results, and shares key insights and lessons learned from this project. Outcomes of the tests and analyses will help OPALCO understand the performance of the Decatur Island BESS in its current state and design appropriate operational strategies for this and other BESSs over the long term.

14 SOLAR ENERGY↗

Spatiotemporal Adaptive Passive Direct Air Capture

Carbon Collect Inc., along with Arizona State University, the Electric Power Research Institute (EPRI), PM Group, and Trimeric Corporation, completed an initial design of a commercial-scale, passive direct air capture (DAC) system termed “carbon trees” that will capture, separate, and store at least 100,000 tonnes/year of carbon dioxide (CO2) from air (net basis). Passive DAC is unique among DAC technologies in that passive air delivery by wind avoids the energy penalty of forced convection. Carbon Collect Inc.’s sorbent-agnostic approach offers the flexibility to choose sorbents for a wide range of climates. A combination of steam, low-grade heat, and vacuum releases the CO2 from the sorbent, which is extracted from the chamber and purified and compressed for geological storage. A commercial carbon tree forest combines the output of several thousand trees for compression and purification with high heat and energy integration. The project team prepared an initial engineering design package for each of three geographically diverse host sites throughout the United States to better understand the effect of local/regional ambient conditions on DAC system performance and project costs. A techno-economic analysis, life cycle analysis, business case analysis, and an environmental, health, and safety risks assessment were also completed for each of the three geographically diverse host sites.

14 SOLAR ENERGY↗

Thermo-Hydrological Modeling of Thermal Energy Storage in a Depleted Oil Reservoir

Thermal energy storage in oil and gas reservoirs leverages the existing surface and subsurface infrastructure, which can pave the way for economic production of geothermal energy. Existing studies on geothermal energy storage are focused mostly on the use of aquifers with more homogeneous rock and fluid properties. Coupling of heat and fluid flow in a multiphase-multicomponent system, such as an oil reservoir, is imperative especially if existing oil field assets need to be repurposed as required for a sustainable energy transition. The objective is to model the subsurface thermo-hydrological processes associated with reservoir performance and operational sustainability. The model evaluates formation pressure and temperature within the reservoir and at the injection/production wells during multiple charge and discharge cycles. Hot water (approximately 200 degrees C) heated by Concentrating Solar Power (CSP) at high pressure is injected into the existing oil reservoir for storage and produced as thermal energy for power generation, which will be accompanied by enhanced oil recovery. To demonstrate the coupled fluid and heat flow during the injection/production cycle in the subsurface reservoir, TOUGH3 (developed by Berkeley Lab) is used to simulate the thermo-hydrological (TH) processes in a multiphase, multicomponent system. Two well geometries are considered within the reservoir grid: 1) a single-well huff-n-puff system (same well is used for injection and production), and 2) an isolated injection-production well doublet. Seasonal charge and discharge cycling are implemented based on the scheduling specified in the model input file. The model reports pressure, temperature, enthalpy, liquid fluxes, heat fluxes, pore velocities, and changes in porosity & permeability due to temperature and pressure variations during the cyclic Reservoir Thermal Energy Storage (RTES) operations. The results from the simulations can be used to optimize the operational parameters (such as well spacing and injection/production rates) and round-trip efficiency for surface power-plants coupled with thermal energy storage over time. They can also serve as important inputs for levelized cost of storage estimations. The research will help to design and integrate surface renewable energy sources, such as concentrating solar power (CSP), with RTES to help balance out power supply and demand on the grid.

CSP↗

Implementing efficient data compression and encryption in a persistent key-value store for HPC

Recently, persistent data structures, like key-value stores (KVSs), which are stored in a high-performance computing (HPC) system’s nonvolatile memory, provide an attractive solution for a number of emerging challenges like limited I/O performance. Data compression and encryption are two well-known techniques for improving several properties of such data-oriented systems. This article investigates how to efficiently integrate data compression and encryption into persistent KVSs for HPC with the ultimate goal of hiding their costs and complexity in terms of performance and ease of use. Our compression technique exploits deep memory hierarchy in an HPC system to achieve both storage reduction and performance improvement. Our encryption technique provides a practical level of security and enables sharing of sensitive data securely in complex scientific workflows with nearly imperceptible cost. We implement the proposed techniques on top of a distributed embedded KVS to evaluate the benefits and costs of incorporating these capabilities along different points in the dataflow path, illustrating differences in effective bandwidth, latency, and additional computational expense on Swiss National Supercomputing Centre’s Grand Tavé and National Energy Research Scientific Computing Center’s Cori.

97 MATHEMATICS AND COMPUTING↗

THE Low-level Radio Frequency System for the superconducting cavities of National Synchrotron Light Source II

A digital low-level radio frequency (LLRF) field controller has been developed for the storage ring of The National Synchrotron Light Source-II (NSLS-II). The primary performance goal for the LLRF is to support the required RF operation of the superconducting cavities with a beam current of 500mA and a 0.14 degree or better RF phase stability. The digital field controller is FPGA-based, in a standard format 19-inch/I-U chassis. It has an option of high-level control support with MATLAB running on a local host computer through a USB2.0 port. The field controller has been field tested with the high-power superconducting RF (SRF) at Canadian light Source, and successfully stored a high beam current of 250 mA. The test results show that required specifications for the cavity RF field stability are met. This digital field controller is also currently being used as a development platform for other functional modules in the NSLS-II RF systems.

43 PARTICLE ACCELERATORS↗

The 1996 Mid-Atlantic Winter Flood: Exploring Climate Risk through a Storyline Approach

Abstract This article explores the application of thermodynamic perturbations to a historical midlatitude, wintertime, rain-on-snow flood event to evaluate how similar events may evolve under different climate forcings. In particular, we generate a hindcast of the 1996 Mid-Atlantic flood using an ensemble of 14-km variable-resolution simulations completed with the U.S. Department of Energy’s global Energy Exascale Earth System Model (E3SM). We show that the event is skillfully reproduced over the Susquehanna River Basin (SRB) by E3SM when benchmarked against in situ observational data and high-resolution reanalyses. In addition, we perform five counterfactual experiments to simulate the flood under preindustrial conditions and four different levels of warming as projected by the Community Earth System Model Large Ensemble. We find a nonlinear response in simulated surface runoff and streamflow as a function of atmospheric warming. This is attributed to changing contributions of liquid water input from a shallower initial snowpack (decreased snowmelt), increased surface temperatures and rainfall rates, and increased soil water storage. Flooding associated with this event peaks from around +1 to +2 K of global average surface warming and decreases with additional warming beyond this. There are noticeable timing shifts in peak runoff and streamflow associated with changes in the flashiness of the event. This work highlights the utility of using storyline approaches for communicating climate risk and demonstrates the potential nonlinearities associated with hydrologic extremes in areas that experience ephemeral snowpack, such as the SRB.

Meteorology & Atmospheric Sciences↗

Advanced Compressors for CO2-Based Power Cycles and Energy

Pumped thermal energy storage (PTES) is a cost-effective method for grid-scale, long-duration electrical energy storage (LDES). PTES uses a heat pump cycle to transfer thermal energy from a low temperature reservoir (LTR) to a high temperature reservoir (HTR), later using a heat engine cycle to reverse the process. A key component of the PTES system, the heat pump compressor, represents a significant driver to the cost, performance and operating characteristics of the PTES system. For grid-scale charging (>100 MW), traditional compressor scaling charts indicate that the operating conditions needed would be best served by a multistage axial compressor. While frame gas turbine compressors at these power ratings exist and operate at higher pressure ratios than needed for the CO2 PTES system, the inlet pressure and fluid density of this application exceed experience values. A conceptual design of a large-scale CO2 axial compressor was completed, including mean-line estimates of the compressor performance at full power conditions. The results of the conceptual design were used to refine the PTES cycle design, and updated operating conditions provided for further aero design optimization. A roughly one third scale of the first three stages of the 100 MW compressor was designed, built, and tested at relevant PTES charging conditions. Results of this test program are compared against high-resolution computational fluid dynamics models.

Compressor Heat↗

Parallel, Multigrid Finite Element Simulator for Fractured/Faulted and Other Complex Reservoirs based on Common Component Architecture (CCA)

Black-oil, compositional and thermal simulators have been developed to address different physical processes in reservoir simulation. A number of different types of discretization methods have also been proposed to address issues related to representing the complex reservoir geometry. These methods are more significant for fractured reservoirs where the geometry can be particularly challenging. In this project, a general modular framework for reservoir simulation was developed, wherein the physical models were efficiently decoupled from the discretization methods. This made it possible to couple any discretization method with different physical models. Oil characterization methods are becoming increasingly sophisticated, and it is possible to construct geologically constrained models of faulted/fractured reservoirs. Discrete Fracture Network (DFN) simulation provides the option of performing multiphase calculations on spatially explicit, geologically feasible fracture sets. Multiphase DFN simulations of and sensitivity studies on a wide variety of fracture networks created using fracture creation/simulation programs was undertaken in the first part of this project. This involved creating interfaces to seamlessly convert the fracture characterization information into simulator input, grid the complex geometry, perform the simulations, and analyze and visualize results. Benchmarking and comparison with conventional simulators was also a component of this work. After demonstration of the fact that multiphase simulations can be carried out on complex fracture networks, quantitative effects of the heterogeneity of fracture properties were evaluated. Reservoirs are populated with fractures of several different scales and properties. A multiscale fracture modeling study was undertaken and the effects of heterogeneity and storage on water displacement dynamics in fractured basements were investigated. In gravity-dominated systems, more oil could be recovered at a given pore volume of injection at lower rates. However, if oil production can be continued at high water cuts, the discounted cumulative production usually favors higher production rates. The workflow developed during the project was also used to perform multiphase simulations in heterogeneous, fracture-matrix systems. Compositional and thermal-compositional simulators were developed for fractured reservoirs using the generalized framework. The thermal-compositional simulator was based on a novel 'equation-alignment' approach that helped choose the correct variables to solve depending on the number of phases present and the prescribed component partitioning. The simulators were used in steamflooding and in insitu combustion applications. The framework was constructed to be inherently parallel. The partitioning routines employed in the framework allowed generalized partitioning on highly complex fractured reservoirs and in instances when wells (incorporated in these models as line sources) were divided between two or more processors.

02 PETROLEUM↗

Fabrication, Modeling, and Testing of a Prototype Thermal Energy Storage Containment

Increasing penetration of variable renewable energy resources requires the deployment of energy storage at a range of durations. Long-duration energy storage (LDES) technologies will fulfill the need to firm variable renewable energy resource output year round; lithium-ion batteries are uneconomical at these durations. Thermal energy storage (TES) is one promising technology for LDES applications because of its siting flexibility and ease of scaling. Particle-based TES systems use low-cost solid particles that have higher temperature limits than the molten salts used in traditional concentrated solar power systems. A key component in particle-based TES systems is the containment silo for the high-temperature (>1100 degrees C) particles. This study combined experimental testing and computational modeling methods to design and characterize the performance of a particle containment silo for LDES applications. A laboratory-scale silo prototype was built and validated the congruent transient finite element analysis (FEA) model. The performance of a commercial-scale silo was then characterized using the validated model. The commercial-scale model predicted a storage efficiency above 95% after 5 days of storage with a design storage temperature of 1200 degrees C. Insulation material and concrete temperature limits were considered as well. The validation of the methodology means the FEA model can simulate a range of scenarios for future applications. This work supports the development of a promising LDES technology with implications for grid-scale electrical energy storage, but also for thermal energy storage for industrial process heating applications.

clean energy↗

Development of an Advanced Hydrogen Energy Storage System using Aerogel in a Cryogenic Flux Capacitor

The Cryogenic Flux Capacitor (CFC) is a cold, dense fluid storage core with integrated design features that afford the designer flexibility and provide new possibilities for the storage and discharge of energy. The stored energy, in this case, is represented by hydrogen physically bonded within the nanoscale pores within the aerogel composite blanket material, and the process of bonding or debonding is governed by the principles of physical adsorption (physisorption) and thermodynamics. The large surface area afforded by the nanoporous aerogel (~1,000 m 2 /g) allows for storage densities close to, or in some cases exceeding, that of normal boiling point liquids. Its performance easily exceeds what can be achieved via ambient temperature and high-pressure gas storage for an equivalent volume. CFC storage is predicted to be easily scalable, constructed from readily available commercial materials, and lends itself to a range of pressure applications. The project team designed and manufactured the CFC, integrating it into a set of temperature-controlled flow loops. The CFC test setup was validated against existing data from previous NASA work. Tests used bottled hydrogen gas for test validation. A cryogenic fluid, nitrogen, flowed through a metered control system. Hydrogen temperature, pressure, and flow rates, as well as the temperature control targets, provided all necessary control targets. The team analyzed the recorded data and updated the Technology Maturation Plan based on the results of the test, making recommendations for a follow-up test, scale-up, and maturation pathway. For the engineering development and maturation of CFC hydrogen storage technology, a Techno-Economic Assessment (TEA) and Commercialization Plan for the integration of this technology with various power generation assets were produced. A companion analytical model was developed, experimentally validated, compared against performance metric, and used to tune the model and scale up the technology.

08 HYDROGEN↗

Solar multiple optimization for a solar-only thermal power plant, using oil as heat transfer fluid in the parabolic trough collectors

Usual size of parabolic trough solar thermal plants being built at present is approximately 50 MW{sub e}. Most of these plants do not have a thermal storage system for maintaining the power block performance at nominal conditions during long non-insolation periods. Because of that, a proper solar field size, with respect to the electric nominal power, is a fundamental choice. A too large field will be partially useless under high solar irradiance values whereas a small field will mainly make the power block to work at part-load conditions. This paper presents an economic optimization of the solar multiple for a solar-only parabolic trough plant, using neither hybridization nor thermal storage. Five parabolic trough plants have been considered, with the same parameters in the power block but different solar field sizes. Thermal performance for each solar power plant has been featured, both at nominal and part-load conditions. This characterization has been applied to perform a simulation in order to calculate the annual electricity produced by each of these plants. Once annual electric energy generation is known, levelized cost of energy (LCOE) for each plant is calculated, yielding a minimum LCOE value for a certain solar multiple value within the range considered. (author)

14 SOLAR ENERGY↗

Fabrication of ultrathin solid electrolyte membranes of β-Li 3 PS 4 nanoflakes by evaporation-induced self-assembly for all-solid-state batteries

All-solid-state lithium batteries are attractive candidates for next-generation energy storage devices because of their anticipated high energy density and intrinsic safety. Owing to their excellent ionic conductivity and stability with metallic lithium anodes, nanostructured lithium thiophosphate solid electrolytes such as β-Li 3 PS 4 have found use in the fabrication of all-solid lithium batteries for large-scale energy storage systems. However, current methods for preparing air-sensitive solid electrolyte membranes of lithium thiophosphates can only generate thick membranes that compromise the battery's gravimetric/volumetric energy density and thus its rate performance. To overcome this limitation, the solid electrolyte's thickness needs to be effectively decreased to achieve ideal energy density and enhanced rate performance. In this paper, we show that the evaporation-induced self-assembly (EISA) technique produces ultrathin membranes of a lithium thiophosphate solid electrolyte with controllable thicknesses between 8 and 50 μm while maintaining the high ionic conductivity of β-Li 3 PS 4 and stability with metallic lithium anodes up to 5 V. Finally, it is clearly demonstrated that this facile EISA approach allows for the preparation of ultrathin lithium thiophosphate solid electrolyte membranes for all-solid-state batteries.

25 ENERGY STORAGE↗

Influence of Metal Identity on Light-Induced Switchable Adsorption in Azobenzene-Based Metal–Organic Frameworks

Energy-efficient capture and release of small gas molecules, particularly carbon dioxide (CO 2 ) and methane (CH 4 ), are of significant interest in academia and industry. Porous materials such as metal–organic frameworks (MOFs) have been extensively studied, as their ultrahigh porosities and tunability enable significant amounts of gas to be adsorbed while also allowing specific applications to be targeted. However, because of the microporous nature of MOFs, the gas adsorption performance is dominated by high uptake capacity at low pressures, limiting their application. Hence, methods involving stimuli-responsive materials, particularly light-induced switchable adsorption (LISA), offer a unique alternative to thermal methods. Here, we report the mechanism of a well-known LISA system, the azobenzene-based material PCN-250, for CO 2 and CH 4 adsorption. There is a noticeable difference in the LISA effect dependent on the metal cluster involved, with the most significant being PCN-250-Al, where the adsorption can change by 83.1% CH 4 and 56.1% CO 2 at 298 K and 1 bar and inducing volumetric storage changes of 36.2 and 33.9 cm 3 /cm 3 at 298 K between 5 and 85 bar (CH 4 ) and 2 and 9 bar (CO 2 ), respectively. Using UV light in both single-crystal X-ray diffraction and gas adsorption testing, we show that upon photoirradiation, the framework undergoes a “localized heating” phenomenon comparable to an increase of 130 K for PCN-250-Fe and improves the working capacity. Furthermore, this process functions because of the constrained nature of the ligand, preventing the typical trans-to-cis isomerization observed in free azobenzene. In addition, we observed that the degree of localized heating is highly dependent on the metal cluster involved, with the series of isostructural PCN-250 systems showing variable performance based upon the degree of interaction between the ligand and the metal center.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗