Search NASA⌕ Search

SEARCH · Search NASA

Results for “High loading rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Anisotropic thermal-conductivity degradation in the phase-field method accounting for crack directionality

Dynamic loads applied to metals may lead to brittle or ductile fracture depending on the imposed strain rates, material properties, and specimen geometry. With an increase in the applied velocity, brittle to ductile failure mode transition may also be observed. Furthermore, at high strain rates, ductile fracture may be preceded by shear bands, which are narrow bands of intense plastic deformation, typically accompanied by a significant rise in temperature. Reliable models are needed to predict the response of metals subject to dynamic loads. In particular, capturing the interplay between heat conduction and crack propagation using the phase-field fracture method is still an open research field. To accurately capture the heat transfer physics across crack surfaces, damage models degrading thermal-conductivity are necessary. While isotropic thermal-conductivity degradation models were proposed, they may lead to errors as they are indifferent to crack directionality. In our current work, a new anisotropic approach is proposed in which thermal-conductivity, which depends on the phase-field gradient, is degraded solely across the crack. Here, it is shown that this approach improves the near-field approximation of temperature and heat flux compared with isotropic degradation, when taking the discontinuous crack solutions as reference. Additionally, the anisotropic degradation approach is implemented in a unified dynamic fracture model and a couple of examples demonstrate the viability of this approach.

42 ENGINEERING↗

SU-F-19A-05: Experimental and Monte Carlo Characterization of the 1 Cm CivaString 103Pd Brachytherapy Source

Purpose: To determine the in-air azimuthal anisotropy and in-water dose distribution for the 1 cm length of the CivaString {sup 103}Pd brachytherapy source through measurements and Monte Carlo (MC) simulations. American Association of Physicists in Medicine Task Group No. 43 (TG-43) dosimetry parameters were also determined for this source. Methods: The in-air azimuthal anisotropy of the source was measured with a NaI scintillation detector and simulated with the MCNP5 radiation transport code. Measured and simulated results were normalized to their respective mean values and compared. The TG-43 dose-rate constant, line-source radial dose function, and 2D anisotropy function for this source were determined from LiF:Mg,Ti thermoluminescent dosimeter (TLD) measurements and MC simulations. The impact of {sup 103}Pd well-loading variability on the in-water dose distribution was investigated using MC simulations by comparing the dose distribution for a source model with four wells of equal strength to that for a source model with strengths increased by 1% for two of the four wells. Results: NaI scintillation detector measurements and MC simulations of the in-air azimuthal anisotropy showed that ≥95% of the normalized data were within 1.2% of the mean value. TLD measurements and MC simulations of the TG-43 dose-rate constant, line-source radial dose function, and 2D anisotropy function agreed to within the experimental TLD uncertainties (k=2). MC simulations showed that a 1% variability in {sup 103}Pd well-loading resulted in changes of <0.1%, <0.1%, and <0.3% in the TG-43 dose-rate constant, radial dose distribution, and polar dose distribution, respectively. Conclusion: The CivaString source has a high degree of azimuthal symmetry as indicated by the NaI scintillation detector measurements and MC simulations of the in-air azimuthal anisotropy. TG-43 dosimetry parameters for this source were determined from TLD measurements and MC simulations. {sup 103}Pd well-loading variability results in minimal variations in the in-water dose distribution according to MC simulations. This work was partially supported by CivaTech Oncology, Inc. through an educational grant for Joshua Reed, John Micka, Wesley Culberson, and Larry DeWerd and through research support for Mark Rivard.

07 ISOTOPE AND RADIATION SOURCES↗

Experimental characterization and analysis of phase change material-based thermal energy storage system for refrigerated display case

Refrigerated display cases that are used to store and exhibit food products in supermarkets and retail spaces consume a significant portion of the buildings’ total electricity. Importantly, the refrigeration-related energy cost and demand charges are greatly affected by the time-of-use electricity pricing and demand rates, which are at their maximum during peak hours, typically when refrigeration energy consumption is also high. Using energy storage to shift the refrigeration load from peak to off-peak hours can greatly reduce the operational costs in the supermarket. This study demonstrates a phase change material-based thermal energy storage (TES) system, specifically designed in stackable units, that can be integrated with an open vertical refrigerated display case. We perform numerical and experimental characterization that includes finite-difference modeling for the TES, prototype fabrication, and laboratory evaluation, followed by a preliminary system-level analysis to predict the impact of TES on the refrigerated case performance, energy use, and energy cost. The results show that the dedicated latent TES for refrigerated cases can provide a specific energy of 50.4 Wh/kg and a specific power of 15.5 W/kg. The TES can be charged during 12 h of the off-peak period and discharged at various rates during 4 to 6 h of the peak period, thereby shifting the refrigeration load from the peak to the off-peak period. Consequently, annual cost savings up to 19% can be achieved, depending on the thermal load, the summer/winter peak electricity pricing, and the transition temperature of the phase change material used.

25 ENERGY STORAGE↗

Plastic flow modeling in glassy polymers

Glassy amorphous and semi-crystalline polymers exhibit strong rate, temperature, and pressure dependent polymeric yield. As a rule of thumb, in uniaxial compression experiments the yield stress increases with the loading rate and applied pressure, and decreases as the temperature increases. Moreover, by varying the loading state itself complex yield behavior can be observed. One example that illustrates this complexity is that most polymers in their glassy regimes (i.e., when the temperature is below their characteristic glass transition temperature) exhibit very pronounced yield in their uniaxial stress stress-strain response but very nebulous yield in their uniaxial strain response. In uniaxial compression, a prototypical glassy-polymer stress-strain curve has a stress plateau, often followed by softening, and upon further straining, a hardening response. Uniaxial compression experiments of this type are typically done from rates of 10{sup -5} s{sup -1} up to about 1 s{sup -1}. At still higher rates, say at several thousands per second as determined from Split Hopkinson Pressure Bar experiments, the yield can again be measured and is consistent with the above rule of thumb. One might expect that that these two sets of experiments should allow for a successful extrapolation to yet higher rates. A standard means to probe high rates (on the order of 105-107 S-I) is to use a uniaxial strain plate impact experiment. It is well known that in plate impact experiments on metals that the yield stress is manifested in a well-defined Hugoniot Elastic Limit (HEL). In contrast however, when plate impact experiments are done on glassy polymers, the HEL is arguably not observed, let alone observed at the stress estimated by extrapolating from the lower strain rate experiments. One might argue that polymer yield is still active but somehow masked by the experiment. After reviewing relevant experiments, we attempt to address this issue. We begin by first presenting our recently developed glassy polymer model. While polymers are well known for their non-equilibrium deviatoric behavior we have found the need for incorporating both equilibrium and non-equilibrium volumetric behavior into our theory. Experimental evidence supporting the notion of non-equilibrium volumetric behavior will be summarized. Our polymer yield model accurately captures the stress plateau, softening and hardening and its yield stress predictions agree well with measured values for several glassy polymers including PMMA, PC, and an epoxy resin. We then apply our theory to plate impact experiments in an attempt to address the questions associated with high rate polymer yield in uniaxial strain configurations.

36 MATERIALS SCIENCE↗

Cu Loading Dependence of Fast NH 3 -SCR on Cu/SSZ-13

The fast NH 3 -SCR kinetics are studied on Cu/SSZ-13 with different Cu loadings, under reaction conditions (temperature and space velocity) where both steady-state and differential NO x conversions are readily achieved. Cu loading is found to greatly influence low-temperature NOx turnover rates, however not to substantially affect apparent activation energies. The high reaction apparent activation energies (~160 kJ/mol) suggest that the rate-limiting kinetics for fast SCR involve the participation of NH 4 NO 3 , an intermediate that is of considerable stability in small pore zeolites. Furthermore, the energetically demanding NH 4 NO 3 + NO reactions make low-temperature fast SCR much slower than standard SCR over Cu-exchanged small pore zeolite catalysts, in drastic contrast to vanadium and medium/large pore based zeolite SCR catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hydrogen production from lignocellulosic hydrolysate in an up-scaled microbial electrolysis cell with stacked bio-electrodes

Hydrogen production from renewable resources via microbial electrolysis cells (MECs) is a promising approach for sustainable energy production. Yet high hydrogen yield from real feedstocks has not been demonstrated in up-scaled MECs. In this study, a 10-L single chamber MEC with a high electrode surface area to volume ratio (66 m 2 /m 3 ) was constructed and electroactive cathodic biofilms were enriched for hydrogen evolution reaction. A high hydrogen yield of 91% was achieved using lignocellulosic hydrolysate with a hydrogen production rate of 0.71 L/L/D at an organic loading rate of 0.4 g/D. The anodic and cathodic microbial communities, with Enterococcus spp. as the known electroactive bacteria, were capable of achieving current densities of 13.7 A/m 2 and 16.5 A/m 2 , respectively. Finally, a machine learning algorithm was used to investigate the correlation between community data and electrochemical performance, and the critical genera on determining current density were identified.

54 ENVIRONMENTAL SCIENCES↗

A three-dimensional carbon nano-network for high performance lithium ion batteries

Three-dimensional (3D) network structure has been envisioned as a superior architecture for lithium ion battery (LIB) electrodes, which enhances both ion and electron transport to significantly improve battery performance. Herein, a 3D carbon nano-network is fabricated through chemical vapor deposition of carbon on a scalably manufactured 3D porous anodic alumina (PAA) template. As a demonstration on the applicability of 3D carbon nano-network for LIB electrodes, the low conductivity active material, TiO 2 , is then uniformly coated on the 3D carbon nano-network using atomic layer deposition. High power performance is demonstrated in the 3D C/TiO 2 electrodes, where the parallel tubes and gaps in the 3D carbon nano-network facilitates fast Li ion transport. A large areal capacity of ~0.37 mAh·cm –2 is achieved due to the large TiO 2 mass loading in the 60 µm-thick 3D C/TiO 2 electrodes. At a test rate of C/5, the 3D C/TiO 2 electrode with 18 nm-thick TiO 2 delivers a high gravimetric capacity of ~240 mAh g –1 , calculated with the mass of the whole electrode. A long cycle life of over 1000 cycles with a capacity retention of 91% is demonstrated at 1C. In this study, the effects of the electrical conductivity of carbon nano-network, ion diffusion, and the electrolyte permeability on the rate performance of these 3D C/TiO 2 electrodes are systematically studied.

25 ENERGY STORAGE↗

Long-term anaerobic digestion of food waste stabilized by trace elements

Highlights: Black-Right-Pointing-Pointer Korean food waste was found to contain low level of trace elements. Black-Right-Pointing-Pointer Stable anaerobic digestion of food waste was achieved by adding trace elements. Black-Right-Pointing-Pointer Iron played an important role in anaerobic digestion of food waste. Black-Right-Pointing-Pointer Cobalt addition further enhanced the process performance in the presence of iron. - Abstract: The purpose of this study was to examine if long-term anaerobic digestion of food waste in a semi-continuous single-stage reactor could be stabilized by supplementing trace elements. Contrary to the failure of anaerobic digestion of food waste alone, stable anaerobic digestion of food waste was achieved for 368 days by supplementing trace elements. Under the conditions of OLR (organic loading rates) of 2.19-6.64 g VS (volatile solid)/L day and 20-30 days of HRT (hydraulic retention time), a high methane yield (352-450 mL CH{sub 4}/g VS{sub added}) was obtained, and no significant accumulation of volatile fatty acids was observed. The subsequent investigation on effects of individual trace elements (Co, Fe, Mo and Ni) showed that iron was essential for maintaining stable methane production. These results proved that the food waste used in this study was deficient in trace elements.

54 ENVIRONMENTAL SCIENCES↗

Harmonic Analysis of Electric Vehicle Loadings on Distribution System

With the increasing number of Electric Vehicles (EV) in this age, the power system is facing huge challenges of the high penetration rates of EVs charging stations. Therefore, a technical study of the impact of EVs charging on the distribution system is required. This paper is applied with PSCAD software and aimed to analyzing the Total Harmonic Distortion (THD) brought by Electric Vehicles charging stations in power systems. The paper starts with choosing IEEE34 node test feeder as the distribution system, building electric vehicle level two charging battery model and other four different testing scenarios: overhead transmission line and underground cable, industrial area, transformer and photovoltaic (PV) system. Then the statistic method is used to analyze different characteristics of THD in the plug-in transient, plug-out transient and steady-state charging conditions associated with these four scenarios are taken into the analysis. Finally, the factors influencing the THD in different scenarios are found. The analyzing results lead the conclusion of this paper to have constructive suggestions for both Electric Vehicle charging station construction and customers' charging habits.

Xu, Yijun A↗

Comparative evaluation of twenty pilot workload assessment measure using a psychomotor task in a moving base aircraft simulator

A comparison of the sensitivity and intrusion of twenty pilot workload assessment techniques was conducted using a psychomotor loading task in a three degree of freedom moving base aircraft simulator. The twenty techniques included opinion measures, spare mental capacity measures, physiological measures, eye behavior measures, and primary task performance measures. The primary task was an instrument landing system (ILS) approach and landing. All measures were recorded between the outer marker and the middle marker on the approach. Three levels (low, medium, and high) of psychomotor load were obtained by the combined manipulation of windgust disturbance level and simulated aircraft pitch stability. Six instrument rated pilots participated in four seasons lasting approximately three hours each.

Connor, S. A.↗

System analysis for the Huntsville Operational Support Center distributed computer system

The Huntsville Operations Support Center (HOSC) is a distributed computer system used to provide real time data acquisition, analysis and display during NASA space missions and to perform simulation and study activities during non-mission times. The primary purpose is to provide a HOSC system simulation model that is used to investigate the effects of various HOSC system configurations. Such a model would be valuable in planning the future growth of HOSC and in ascertaining the effects of data rate variations, update table broadcasting and smart display terminal data requirements on the HOSC HYPERchannel network system. A simulation model was developed in PASCAL and results of the simulation model for various system configuraions were obtained. A tutorial of the model is presented and the results of simulation runs are presented. Some very high data rate situations were simulated to observe the effects of the HYPERchannel switch over from contention to priority mode under high channel loading.

Ingels, F. M.↗

Mechanotransduction and the functional response of bone to mechanical strain

Mechanotransduction plays a crucial role in the physiology of many tissues including bone. Mechanical loading can inhibit bone resorption and increase bone formation in vivo. In bone, the process of mechanotransduction can be divided into four distinct steps: (1) mechanocoupling, (2) biochemical coupling, (3) transmission of signal, and (4) effector cell response. In mechanocoupling, mechanical loads in vivo cause deformations in bone that stretch bone cells within and lining the bone matrix and create fluid movement within the canaliculae of bone. Dynamic loading, which is associated with extracellular fluid flow and the creation of streaming potentials within bone, is most effective for stimulating new bone formation in vivo. Bone cells in vitro are stimulated to produce second messengers when exposed to fluid flow or mechanical stretch. In biochemical coupling, the possible mechanisms for the coupling of cell-level mechanical signals into intracellular biochemical signals include force transduction through the integrin-cytoskeleton-nuclear matrix structure, stretch-activated cation channels within the cell membrane, G protein-dependent pathways, and linkage between the cytoskeleton and the phospholipase C or phospholipase A pathways. The tight interaction of each of these pathways would suggest that the entire cell is a mechanosensor and there are many different pathways available for the transduction of a mechanical signal. In the transmission of signal, osteoblasts, osteocytes, and bone lining cells may act as sensors of mechanical signals and may communicate the signal through cell processes connected by gap junctions. These cells also produce paracrine factors that may signal osteoprogenitors to differentiate into osteoblasts and attach to the bone surface. Insulin-like growth factors and prostaglandins are possible candidates for intermediaries in signal transduction. In the effector cell response, the effects of mechanical loading are dependent upon the magnitude, duration, and rate of the applied load. Longer duration, lower amplitude loading has the same effect on bone formation as loads with short duration and high amplitude. Loading must be cyclic to stimulate new bone formation. Aging greatly reduces the osteogenic effects of mechanical loading in vivo. Also, some hormones may interact with local mechanical signals to change the sensitivity of the sensor or effector cells to mechanical load.

Non-NASA Center↗

An Optimized Input/Output-Constrained Control Design With Application to Microgrid Operation

In this paper, a nonlinear control design is presented for systems whose input and output vectors are saturated. The proposed synthesis includes an optimal tracker as the seed controller and explicitly imposes all the relevant constraints on system input, on the rate of change in the input, and on system output by using the tools of barrier functions, input-output feedback linearization, comparison argument, Lyapunov argument, and a real-time constrained optimization. The proposed design is applied to microgrid operation with high penetration of renewable generation, where net load and variable generation must be balanced and the microgrid should be operated at an optimal or near-optimal performance level. Since traditional generation has a limited ramping rate, battery storage devices and demand responses become necessary to effectively deal with variability of renewable generation and to maintain frequency stability, but their capacities are also limited. Finally,it is shown that the proposed design is effective for coordinated control of traditional generation, storage and demand response so that the power system frequency is guaranteed to be within the required operational limits and that renewable curtailment is eliminated or minimized.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multirate delivery of multiple therapeutic agents from metal-organic frameworks

The highly porous nature of metal-organic frameworks (MOFs) offers great potential for the delivery of therapeutic agents. Here, we show that highly porous metal-organic frameworks can be used to deliver multiple therapeutic agents—a biologically active gas, an antibiotic drug molecule, and an active metal ion—simultaneously but at different rates. The possibilities offered by delivery of multiple agents with different mechanisms of action and, in particular, variable timescales may allow new therapy approaches. Here, we show that the loaded MOFs are highly active against various strains of bacteria.

36 MATERIALS SCIENCE↗

Decomposition characteristics of C4F7N-based SF6-alternative gas mixtures

C4F7N [2,3,3,3-tetrafluoro-2-(trifluoromethyl)propanenitrile]/CO2 gas mixtures are being developed as an eco-friendly electrical insulator to replace SF6, the most potent greenhouse industrial gaseous dielectric. However, recent studies have reported complicated and often conflicting decomposition pathways for C4F7N/CO2 gas mixtures, which has raised concerns. In this work, the decomposition characteristics of C4F7N/CO2 gas mixtures were studied comprehensively by both designed computations and experiments. Computations were performed starting from fundamental propositions of C4F7N/CO2 decompositions, which were further experimentally verified by pyrolysis, long-term thermal aging with/without catalytic materials (industrial-grade molecular sieves 4A), and electrical decomposition by spark discharge. The results of both computations and experiments suggest that in an ideal thermal decomposition, C4F7N is likely to decompose into C2F6 and small fluoronitriles first at high temperatures. The generation of C3F6 and C2N2 from C4F7N thermal decomposition at lower temperatures appears because of the catalytic effect of incompatible materials, for example, the industrial-grade molecular sieves 4A that we tested. The electron impact dissociation of C4F7N plays an important role in C4F7N electrical decomposition, leading to additional formation of distinctive small molecules of CF4 and C2N2 of low concentrations. It was pointed out based on a real arcing test in a load disconnector that the decomposition of C4F7N gas mixtures in real applications will be at a much moderate and manageable rate than what was obtained from the highly accelerated laboratory tests presented in this work. The signatures of decomposition products extracted in this study provide invaluable guidance for developing decomposition-based diagnosis and fixation of decomposition byproducts toward SF6-free power grids.

Physics↗

Lubrication of high-speed, large bore tapered-roller bearings

The performance of 120.65-mm bore tapered-roller bearings was investigated at shaft speeds up to 15,000 rpm. Temperature distribution and bearing heat generation were determined as a function of shaft speed, radial and thrust loads, lubricant flow rate, and lubricant inlet temperature. Lubricant was supplied either by jets or by a combination of holes through the cone directly to the cone-rib contact and jets at the roller small-end side. Cone-rib lubrication significantly improved high-speed tapered-roller bearing performance, yielding lower cone-face temperatures and lower power loss and allowing lower lubricant flow rates for a given speed condition. Bearing temperatures increased with increased shaft speed and decreased with increased lubricant flow rate. Bearing power loss increased with increased shaft speed and increased lubricant flow rate.

Parker, R. J.↗

Jet formation in GRBs: a semi-analytic model of MHD flow in Kerr geometry with realistic plasma injection

We construct a semi-analytic model for magnetohydrodynamic (MHD) flows in Kerr geometry that incorporates energy loading via neutrino annihilation on magnetic field lines threading the horizon. We compute the structure of the double-flow established in the magnetisphere for a wide range of energy injection rates and identify the different operation regimes. At low injection rates, the outflow is powered by the spinning black hole via the Blandford-Znajek mechanism, whereas at high injection rates, it is driven by the pressure of the plasma deposited on magnetic field lines. In the intermediate regime, both processes contribute to the outflow formation. The parameter that quantifies the load is the ratio of the net power injected below the stagnation radius and the maximum power that can be extracted magnetically from the black hole.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance of a 100V Half-Bridge MOSFET Driver, Type MIC4103, Over a Wide Temperature Range

The operation of a high frequency, high voltage MOSFET (metal-oxide semiconductor field-effect transistors) driver was investigated over a wide temperature regime that extended beyond its specified range. The Micrel MIC4103 is a 100V, non-inverting, dual driver that is designed to independently drive both high-side and low-side N-channel MOSFETs. It features fast propagation delay times and can drive 1000 pF load with 10ns rise times and 6 ns fall times [1]. The device consumes very little power, has supply under-voltage protection, and is rated for a -40 C to +125 C junction temperature range. The floating high-side driver of the chip can sustain boost voltages up to 100 V. Table I shows some of the device manufacturer s specification.

Patterson, Richard L.↗