Ultrahigh-spatial-resolution chemical and magnetic imaging by laser-based photoemission electron microscopy

We report the first experiments carried out on a new chemical and magnetic imaging system, which combines the high spatial resolution of a photoemission electron microscope (PEEM) with a continuous-wave deep-ultraviolet laser. Threshold photoemission is sensitive to the chemical and magnetic structures of the surface of materials. The spatial resolution of PEEM is limited by space charging when using pulsed photon sources as well as aberrations in the electron optics. We show that the use of a continuous-wave laser enabled us to overcome such a limit by suppressing the space-charge effect, allowing us to obtain a resolution of approximately 2.6 nm. With this system, we demonstrated the imaging of surface reconstruction domains on Si(001) by linear dichroism with normal incidence of the laser beam. We also succeeded in magnetic imaging of thin films with the use of magnetic circular dichroism near the Fermi level. The unique features of the ultraviolet laser will give us fast switching of the incident angles and polarizations of the photon source, which will be useful for the characterization of antiferromagnetic materials as well as ferromagnetic materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High resolution near-infrared imaging of the trapezium: A stellar census

We present high spatial resolution (0.35 and 0.65 arcsec full width at half maximum (FWHM)) near-infrared images of the central 0.2x0.2 pc of the Trapezium Cluster in the Orion Nebula, centered on the Trapezium OB stars. These images provide the most complete census of stars in this region, and we give accurate positions and near-infrared (2.1 microns) magnitudes for 123 stars. After accounting for line-of-sight projection, we estimate a stellar density for the cluster of approximately 4.7 X 10(exp 4) stars per cubic parsec in the approximately 0.1 pc diameter core. We identify stellar counterparts to virtually all the known dense knots of ionized gas seen at optical and radio wavelengths, strongly supporting the hypothesis that many are either intrinsic stellar radio emitters or circumstellar disks around stars, and not simply dense clumps of gas and dust. We derive approximate masses for the stars associated with the compact knots, finding that the majority are relatively low mass.

Mccaughrean, Mark J.↗

Optimized generation of high resolution breast anthropomorphic software phantoms

Purpose: The authors present an efficient method for generating anthropomorphic software breast phantoms with high spatial resolution. Employing the same region growing principles as in their previous algorithm for breast anatomy simulation, the present method has been optimized for computational complexity to allow for fast generation of the large number of phantoms required in virtual clinical trials of breast imaging. Methods: The new breast anatomy simulation method performs a direct calculation of the Cooper's ligaments (i.e., the borders between simulated adipose compartments). The calculation corresponds to quadratic decision boundaries of a maximum a posteriori classifier. The method is multiscale due to the use of octree-based recursive partitioning of the phantom volume. The method also provides user-control of the thickness of the simulated Cooper's ligaments and skin. Results: Using the proposed method, the authors have generated phantoms with voxel size in the range of (25-1000 {mu}m){sup 3}/voxel. The power regression of the simulation time as a function of the reciprocal voxel size yielded a log-log slope of 1.95 (compared to a slope of 4.53 of our previous region growing algorithm). Conclusions: A new algorithm for computer simulation of breast anatomy has been proposed that allows for fast generation of high resolution anthropomorphic software phantoms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gamma-Ray Focusing Optics for Small Animal Imaging

There is a well-established need for high-resolution radionuclide imaging techniques that provide non-invasive measurement of physiological function in small animals. We, therefore, have begun developing a small animal radionuclide imaging system using grazing incidence mirrors to focus low-energy gamma-rays emitted by I-125, and other radionuclides. Our initial prototype optic, fabricated from thermally-formed glass, demonstrated a resolution of 1500 microns, consistent with the performance predicted by detailed simulations. More recently, we have begun constructing mirrors using a replication technique that reduces low spatial frequency errors in the mirror surface, greatly improving the resolution. Each technique offers particular advantages: e.g., multilayer coatings are easily deposited on glass, while superior resolution is possible with replicated optics. Scaling the results from our prototype optics, which only have a few nested shells, to system where the lens has a full complement of several tens of nested shells, a sensitivity of approx. 1 cps/micro Ci is possible, with the exact number dependent on system magnification and radionuclide species. (Higher levels of efficiency can be obtained with multi-optic imaging systems.) The gamma-ray lens will achieve a resolution as good as 100 microns, independent of the final sensitivity. The combination of high spatial resolution and modest sensitivity will enable in vivo single photon emission imaging studies in small animals.

Pivovaroff, M. J.↗

Sensitivity of deep convection and cross-tropopause water transport to microphysical parameterizations in WRF

Deep convective storms can overshoot the tropopause, thus altering the composition of the stratosphere by vertically transporting tropospheric air. The transport of water vapor and ice particles into a sub-saturated environment can hydrate the stratosphere, with implications for radiative forcing and ozone chemistry. Cloud-resolved models, if employed at high spatial resolutions, are used to probe process-level questions about cross-tropopause deep convective hydration and its controls. There is considerable diversity in model representations of processes associated with water transport and transformation, and the choice of a microphysics scheme affects model skill in simulating deep convective events. This motivates our evaluation of state-of-the-art, as well as widely used standard schemes, in a high spatial- and temporal-resolution framework. Six bulk microphysics schemes were employed in a WRF-LES setup, initialized with a sounding profile representative of a tropopause-overshooting storm. Here, we used an idealized framework to isolate the effect of microphysics on the dominant processes that control the reach of deep convection and stratospheric hydration. All schemes produced the highest reaching updrafts 8-12 hours into the simulation but the strength and persistence of updrafts varied across the schemes; maximum storm heights ranged 9.1-12.6 km across the schemes. Varying microphysics produced large differences in the vertical extent and horizontal aggregation of convection, and an order of magnitude spread in above-tropopause water vapor concentrations.

54 ENVIRONMENTAL SCIENCES↗

A theoretical and experimental evaluation of the microangiographic fluoroscope: A high-resolution region-of-interest x-ray imager

Purpose: The increasing need for better image quality and high spatial resolution for successful endovascular image-guided interventions (EIGIs) and the inherent limitations of the state-of-the-art detectors provide motivation to develop a detector system tailored to the specific, demanding requirements of neurointerventional applications.Method: A microangiographic fluoroscope (MAF) was developed to serve as a high-resolution, region-of-interest (ROI) x-ray imaging detector in conjunction with large lower-resolution full field-of-view (FOV) state-of-the-art x-ray detectors. The newly developed MAF is an indirect x-ray imaging detector capable of providing real-time images (30 frames per second) with high-resolution, high sensitivity, no lag and low instrumentation noise. It consists of a CCD camera coupled to a Gen 2 dual-stage microchannel plate light image intensifier (LII) through a fiber-optic taper. A 300 {mu}m thick CsI(Tl) phosphor serving as the front end is coupled to the LII. The LII is the key component of the MAF and the large variable gain provided by it enables the MAF to operate as a quantum-noise-limited detector for both fluoroscopy and angiography. Results: The linear cascade model was used to predict the theoretical performance of the MAF, and the theoretical prediction showed close agreement with experimental findings. Linear system metrics such as MTF and DQE were used to gauge the detector performance up to 10 cycles/mm. The measured zero frequency DQE(0) was 0.55 for an RQA5 spectrum. A total of 21 stages were identified for the whole imaging chain and each stage was characterized individually. Conclusions: The linear cascade model analysis provides insight into the imaging chain and may be useful for further development of the MAF detector. The preclinical testing of the prototype detector in animal procedures is showing encouraging results and points to the potential for significant impact on EIGIs when used in conjunction with a state-of-art flat panel detector (FPD).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combining Spatial and Temporal Resolution in Cryo-TEM of Device Materials: Preprint

Cryogenic transmission electron microscopy (cryo-TEM) has been instrumental to reducing the effects of electron-beam sample interactions and enabling higher spatial resolution studies of beam sensitive materials. However, the process of thinning and freezing samples for cryo-TEM characterization is often complex and frequently involves removing materials from their environment or stimuli of interest for extended times. This can allow for structural relaxation, diffusion, and other dynamic processes to occur prior to characterization; for energy materials like battery electrodes, this makes it difficult to precisely correlate the imaged structure with native structures that evolve in-situ during device processing, operation, or aging. Here, we present methods to prepare cryo-TEM samples from energy materials during these critical processes in the relevant device lifetimes. This offers insights into improving the temporal resolution of cryo-TEM, while still exploiting its ability to achieve high spatial resolutions in characterizing beam sensitive materials.

BASIC BIOLOGICAL SCIENCES,MATERIALS SCIENCE↗

A finite difference informed random walker (FDiRW) solver for strongly inhomogeneous diffusion problems

In nature, many complex multi-physics coupling problems exhibit strong diffusivity inhomogeneity. For instance, in the context of radionuclide absorption by porous wasteform materials within a flowing waste stream, the difference of species’ diffusivity in solid and liquid phases spans by 3~8 orders of magnitude. To solve the diffusion equations with strongly inhomogeneous diffusivity, traditional discretization-based methods, such as the Finite Difference Method (FDM), require infinitesimally small time steps (<10 -10 ) as high spatial resolutions are employed in most microstructure evolution processes, leading to prohibitively high computational costs. Here, this work developed an integrated numerical approach (FDiRW: Finite Difference informed Random Walk) to tackle this challenge. The idea is that utilizing the Random Walk concept, the fast diffusion is modeled as a superposition of point source’s solution for a concentration distribution while FDM is used to obtain the point source’s solution at each node. A mesh-coarsening algorithm is developed to generate an exclusive coarse mesh for FDiRW approach to maximize its efficiency. The effectiveness of the coarse mesh-based FDiRW approach is validated by benchmarking Finite Difference solutions. Numerical results demonstrated that FDiRW achieves a remarkable 1000x computational efficiency improvement over FDM while preserving desired accuracy for a medium-sized model of 192 × 192 × 192 grids. Finally, as models scale up, a floating-point operations (PLOPs) analysis of the FDiRW algorithm reveals that its computational complexity grows quadratically in terms of the number of nodes employed in computation.

36 MATERIALS SCIENCE↗

A multi-criteria CCUS screening evaluation of the Gulf of Mexico, USA

Continued research into reservoir characterization along with offshore carbon dioxide (CO 2 ) transportation and infrastructure assets is needed to facilitate development of safe and successful carbon capture, utilization, and storage (CCUS) projects. This paper outlines a multi-criteria evaluation methodology that incorporates disparate sets of quantitative, spatially variable data into a decision-making framework for screening the Gulf of Mexico (GOM) outer continental shelf (OCS) for potentially viable CO 2 storage and enhanced oil recovery (EOR) sites. Criteria categories include favorable geologic characteristics, logistics, and potential risks. Data compiled for 14 criteria from several publicly available geographic information system (GIS) layers was aggregated over 2559 spatially balanced points across the study area using the National Energy Technology Laboratory (NETL)-developed Cumulative Spatial Impact Layers™ (CSIL) GIS tool. Criteria are weighted by qualitative expert opinion relative to their perceived importance to given scenarios— the output of combined criteria values and weights enables regional CO 2 storage suitability differentiation. The methodology considers both technical and non-technical factors impacting CCUS decision-making. The flexible methodology enables a systematic approach to regional ranking at high spatial resolution over a large study domain. Additionally, the framework enables high-grading of priority sites that warrant further characterization and follow-on analysis. Areas along the Louisiana coast and Mississippi River Delta consistently rank high for all scenarios largely a result of the favorable geology with the potential for stacked storage, as well as the density of existing pipelines and platforms, and proximity to several onshore CO 2 sources. High-graded regions for the CO 2 EOR-related scenarios are typically located further offshore towards the middle and edge of the OCS compared to higher priority regions for the geologic storage scenarios which fall closer to the Louisiana coastline.

54 ENVIRONMENTAL SCIENCES↗

Fast lithium growth and short circuit induced by localized-temperature hotspots in lithium batteries

Fast-charging and high-energy-density batteries pose significant safety concerns due to high rates of heat generation. Understanding how localized high temperatures affect the battery is critical but remains challenging, mainly due to the difficulty of probing battery internal temperature with high spatial resolution. Here we introduce a method to induce and sense localized high temperature inside a lithium battery using micro-Raman spectroscopy. We discover that temperature hotspots can induce significant lithium metal growth as compared to the surrounding lower temperature area due to the locally enhanced surface exchange current density. More importantly, localized high temperature can be one of the factors to cause battery internal shorting, which further elevates the temperature and increases the risk of thermal runaway. This work provides important insights on the effects of heterogeneous temperatures within batteries and aids the development of safer batteries, thermal management schemes, and diagnostic tools.

25 ENERGY STORAGE↗

The IRS 1 circumstellar disk, and the origin of the jet and CO outflow in B5

We report the discovery of the inner edge of the high velocity CO outflow associated with the bipolar jet originating from IRS 1 in Barnard 5 and the first ever resolution of its circumstellar disk in the 2.6 mm dust continuum and C18O. From high spatial resolution observations made with the Owens Valley Millimeter Array we are able to locate the origin of the outflow to within approximately 500 AU on either side of IRS 1 and apparently at the edge of, or possibly within, its circumstellar disk. The orientation of the continuum disk is perpendicular to the highly collimated jet outflow recently seen in optical emission at much farther distances. The disk has been detected in C18O giving a disk mass approximately 0.16 M (solar). Our HCO+ and HCN maps indicate significant chemical differentiation in the circumstellar region on small scales with HCO+ tracing an extended disk of material. The 12CO interferometer maps of the outflow show two conelike features originating at IRS 1, the blue one fanning open to the northeast and the red one to the southwest. The vertices of the cones are on either side of the circumstellar disk and have a projected opening angle of about 90 degrees. The intrinsic opening angle is in the range of 60 degrees-90 degrees which leads to significant interaction between outflow and infall.

NASA Center JPL↗

High-resolution magnetic microscopy applications using nitrogen-vacancy centers in diamond

Magnetic microscopy with high spatial resolution helps to solve a variety of technical problems in condensed-matter physics, electrical engineering, biomagnetism, and geomagnetism. In this work we used quantum diamond magnetic microscope (QDMM) setups, which use a dense uniform layer of magnetically-sensitive nitrogen-vacancy (NV) centers in diamond to image an external magnetic field using a fluorescence microscope. We used this technique for imaging few-micron ferromagnetic needles used as a physically unclonable function (PUF) and to passively interrogate electric current paths in a commercial 555 timer integrated circuit (IC). As part of the QDMM development, we also found a way to calculate ion implantation recipes to create diamond samples with dense uniform NV layers at the surface. This work opens the possibility for follow-up experiments with 2D magnetic materials, ion implantation, and electronics characterization and troubleshooting.

36 MATERIALS SCIENCE↗

High-Resolution 3D Acoustic Borehole Integrity Monitoring (Final Report)

Real-time, in-situ, high spatial resolution (sub-cm) imaging of the near-borehole environment would revolutionize wellbore diagnostics and integrity assessment by direct observation of defects. It is becoming increasingly apparent, that better understanding of the near-wellbore environment is required to meet the safety and operational needs in challenging environments such as those present in subsurface energy extraction (geothermal) and storage (CO2 sequestration) applications. Therefore, it is important to have a more robust ability to image the near-borehole and reliably detect defects. It was proposed to further develop and improve our advanced 3D imaging system to evaluate casing defects (e.g. corrosion) and cement quality in either open- or cased-borehole with the ultimate goal to develop a commercially deployable technology. The system consists of a unique acoustic source (LANL) and advanced inversion techniques for image processing (LANL, ORNL). This system will provide comprehensive borehole integrity monitoring with improved resolution over existing techniques. As an application of this imaging system, we will characterize the effectiveness of next-generation wellbore completion technology (NETL, SNL), and will demonstrate that, unlike current technology, the proposed approach can successfully characterize foamed cements.

42 ENGINEERING↗

Atmospheric correction of high resolution land surface images

Algorithms to correct for atmospheric-scattering effects in high-spatial resolution land-surface images require the ability to perform rapid and accurate computations of the top-of-atmosphere diffuse radiance field for arbitrarily general surface reflectance distributions (which may be both heterogeneous and non-Lambertian) and atmospheric models. Using three-dimensional radiative transfer (3DRT) theory algorithms are being developed. The methodology used to perform the 3DRT calculations is described. It is shown how these calculations are used to perform atmospheric corrections, and the sensitivity of the retrieved surface reflectances to atmospheric structural parameters is illustrated.

Diner, D. J.↗

Direct observation of unstained wet biological samples by scanning-electron generation X-ray microscopy

Analytical tools of nanometre-scale resolution are indispensable in the fields of biology, physics and chemistry. One suitable tool, the soft X-ray microscope, provides high spatial resolution of visible light for wet specimens. For biological specimens, X-rays of water-window wavelength between carbon (284 eV; 4.3 nm) and oxygen (540 eV; 2.3 nm) absorption edges provide high-contrast imaging of biological samples in water. Among types of X-ray microscope, the transmission X-ray microscope using a synchrotron radiation source with diffractive zone plates offers the highest spatial resolution, approaching 15-10 nm. However, even higher resolution is required to measure proteins and protein complexes in biological specimens; therefore, a new type of X-ray microscope with higher resolution that uses a simple light source is desirable. Here we report a novel scanning-electron generation X-ray microscope (SGXM) that demonstrates direct imaging of unstained wet biological specimens. We deposited wet yeasts in the space between two silicon nitride (Si{sub 3}N{sub 4}) films. A scanning electron beam of accelerating voltage 5 keV and current 1.6 nA irradiates the titanium (Ti)-coated Si{sub 3}N{sub 4} film, and the soft X-ray signal from it is detected by an X-ray photodiode (PD) placed below the sample. The SGXM can theoretically achieve better than 5 nm resolution. Our method can be utilized easily for various wet biological samples of bacteria, viruses, and protein complexes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiscale assessment of land surface phenology from harmonized Landsat 8 and Sentinel-2, PlanetScope, and PhenoCam imagery

As the spatial and temporal resolution of remotely sensed imagery has improved over the last four decades, algorithms for monitoring and mapping seasonal changes in surface properties have evolved rapidly. Most recently, the availability of daily PlanetScope imagery has created new opportunities for monitoring the land surface phenology (LSP) of terrestrial ecosystems at high spatial resolution. However, the quality and value of LSP information from PlanetScope imagery have not been systematically examined. In this paper, we evaluate the character and quality of LSP information derived from PlanetScope by comparing time series of vegetation indices and LSP metrics from PlanetScope to corresponding time series and LSP metrics derived from Harmonized Landsat 8 and Sentinel-2 (HLS) imagery and PhenoCams at six sites that span a diverse range of land cover types and climate. Results show that vegetation index time series from all three data sources show high temporal correlation, and LSP metrics derived from HLS, PlanetScope, and PhenoCam show high agreement with negligible bias. Semi-variograms for phenometrics estimated from PlanetScope imagery indicate that the majority of spatial variance captured in PlanetScope phenometrics occurs well below the spatial resolution HLS imagery. At the same time, LSP metrics from HLS are most strongly correlated with the 50–75% quantiles of 3 m LSP metrics from PlanetScope. This indicates that HLS captures the average phenology at sub-pixel scale captured in PlanetScope imagery. Here, our results represent the first comprehensive comparison of LSP metrics estimated from PlanetScope and publicly available moderate spatial resolution imagery, and provide insights regarding: (1) the quality and character of LSP metrics derived from HLS and PlanetScope; and (2) the relative merits and trade-offs associated with the use of each data source for LSP studies.

54 ENVIRONMENTAL SCIENCES↗