Search NASA⌕ Search

SEARCH · Search NASA

Results for “IRRADIATION DEVICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Research on radiation detectors, boiling transients, and organic lubricants

The accomplishments of a space projects research facility are presented. The subjects discussed are: (1) a study of radiation resistant semiconductor devices, (2) synthesis of high temperature organic lubricants, (3) departure from phase equilibrium during boiling transients, (4) effects of neutron irradiation on defect state in tungsten, and (5) determination of photon response function of NE-213 liquid scintillation detectors.

Source record↗

Tissue oxygen measurement system

A device and method in accordance with the invention for determining the oxygen partial pressure (PO.sub.2) of a tissue by irradiating the tissue with optical radiation such that the light is emitted from the tissue, and by collecting the reflected or transmitted light from the tissue to form an optical spectrum. A spectral processor determines the PO.sub.2 level in tissue by processing this spectrum with a previously-constructed spectral calibration model. The tissue may, for example, be disposed underneath a covering tissue, such as skin, of a patient, and the tissue illuminated and light collected through the skin. Alternatively, direct tissue illumination and collection may be effected with a hand-held or endoscopic probe. A preferred system also determines pH from the same spectrum, and the processor may determine critical conditions and issue warnings based on parameter values.

Soller, Babs R.↗

Single-Event Testing of the Texas Instruments SNV54LVC00AW Quadruple 2-Input Positive-NAND Gates

The purpose of this testing was to characterize the Texas Instruments SNV54LVC00AW for single-event latchup (SEL) in support of a NASA GSFC flight program. The SNV54LVC00A quadruple 2-input positive-NAND gate. These devices were tested at the Berkeley Accelerator Space Effects (BASE) Facility at Lawrence Berkeley National Laboratory (LBNL) where they were irradiated with the 10 MeV/amu heavy ion cocktail.

Campola, Michael↗

Neutron, gamma ray and post-irradiation thermal annealing effects on power semiconductor switches

The effects of neutron and gamma rays on the electrical and switching characteristics of power semiconductor switches must be known and understood by the designer of the power conditioning, control, and transmission subsystem of space nuclear power systems. The SP-100 radiation requirements at 25 m from the nuclear source are a neutron fluence of 10(exp 13) n/sq cm and a gamma dose of 0.5 Mrads. Experimental data showing the effects of neutrons and gamma rays on the performance characteristics of power-type NPN Bipolar Junction Transistors (BJTs), Metal-Oxide-Semiconductor Field Effect Transistors (MOSFETs), and Static Induction Transistors (SITs) are presented. These three types of devices were tested at radiation levels which met or exceeded the SP-100 requirements. For the SP-100 radiation requirements, the BJTs were found to be most sensitive to neutrons, the MOSFETs were most sensitive to gamma rays, and the SITs were only slightly sensitive to neutrons. Post-irradiation thermal anneals at 300 K and up to 425 K were done on these devices and the effectiveness of these anneals are also discussed.

Schwarze, G. E.↗

The Determination of Radiation Hardness of Semiconductor Materials and Devices with Ion Beams

lon accelerator based techniques provide unique tools to gain insight into the phenomena underlying the formation of defects induced by energetic particles in semiconductor materials and their effects on the electronic features of the device. In recognition of the potential of these techniques, with the aim of enhancing the understanding of the mechanisms underlying the degradation of the performances of semiconductor devices induced by ionizing radiation, the IAEA established a Research Project, coordinated by the Physics Section (CRP F11016) entitled "Utilization of ion accelerators for studying and modelling of radiation induced defects in semiconductors and insulators" at the end of 2011. The objective of this IAEA Coordinated Research Project (CRP) was to enhance the capabilities of the interested Member States by facilitating their collective efforts to use accelerator-based ion irradiation of electronic materials in conjunction with available advanced characterization techniques to gain a deeper understanding of how different types of radiation influences the electronic properties of materials and devices, leading to an improved radiation hardness. A dynamic and productive research was stimulated by this CRP among collaborating partners, resulting in publications in scientific journals [CRP2016], educational and scientific software packages [W8, Forneris2014], and a number of collaborations among the participating research groups. Two of the most significant outcomes of this project are i) the experimental protocol, which rationalizes the use of the many existing characterization techniques adopted to investigate radiation effects in semiconductor devices and ii) the relevant theoretical approach to interpret the experimental data [Vittone2016 and references therein]. This publication integrates output of research articles published by the partners of the CRP and is aimed to provide an exhaustive description of the experimental protocol, the theoretical model with the relevant limits of application, the data analysis procedure, and the physical observables which can be effectively measured and which can be used for assessment of the radiation hardness of semiconductor devices. The intended audience of this report includes all those professionals and technologists working in ion beam functional analysis of semiconductor materials, solid-state physicists and engineers involved in the design of electronic devices working in radiation harsh environments.

36 MATERIALS SCIENCE↗

Variation in the electrical properties of ion beam irradiated cadmium selenate nanowires

The key feature of nanowires consists in the pronounced change in properties induced by the low dimensionality and high surface to volume ratio. The study of electrical transport properties of nanowires is important for electronic device applications. Energetic ions create changes, which may be structural or chemical, in a material along their track and these changes might alter the material’s properties. The demand of the modern technology is to understand the effect of radiation on the different properties of the material for its further applications. The present study is on the high-energy Nickel ion beam (160 MeV Ni{sup +12}) induced modifications in the electrical and structural properties of the cadmium selenate nanowires. An enhancement in the electrical conductivity of irradiated wires was observed as the ion fluence was increased especially in the forward I–V characteristics. The creation of defects by ion irradiation and the synergy of the ions during their passage in the sample with the intrinsic charge carriers may be responsible for the variation in the transport properties of the irradiated nanowires.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Thermal conductivity measurement of the interaction layer between UMo and Al produced by high-energy heavy ion irradiation

In this work, we report the first direct thermal conductivity measurement results for Al-UMo interaction layer (IL), which is typically observed in UMo/Al dispersion fuel plates under irradiation. The investigated IL was formed by irradiating Al coated UMo substrate using 80 MeV iodine ions at 180 degrees C up to 3.03 x 10 17 ions/cm 2 fluence. Microstructural characterization indicated that the induced IL is amorphous with an approximately (U 0.8 ,Mo 0.2 )Al 5.3 stoichiometry, which is similar to that formed under in-pile irradiation. Focused ion beam (FIB) was used to prepare nine specimens of various lengths from the IL that could be suspended across a microfabricated device for thermal conductivity measurement. The measured thermal conductivity values of the IL were significantly lower than the values for both the original UMo fuel and the Al. The successful measurement of the Al-UMo IL provides valuable information for the development and qualification of UMo/Al dispersion fuels for research and test reactor conversion applications, and further demonstrates the promising capabilities of utilizing the suspended bridge method in nuclear fuel research.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Latest Results from Proto-MPEX and the Future Plans for MPEX

The Prototype Material Plasma Exposure eXperiment (Proto-MPEX) is being used to qualify the plasma source and heating systems for the Material Plasma Exposure eXperiment (MPEX). The MPEX will address important and urgent research needs on plasma material interactions for future fusion reactors. In MPEX, plasma-facing components (nonirradiated and a priori neutron irradiated) will be exposed to plasma conditions as they are expected in future fusion reactors. The MPEX, a steady-state device enabled by superconducting magnets, will be able to break into new ground by assessing plasma-facing materials and components at an ion fluence level in the range of 10 30 to 10 31 m -2 . To achieve the relevant plasma conditions, high-density plasmas (>4 × 10 19 m -3 ) are produced with a high-power helicon source. The so-produced low-temperature helicon plasma is then additionally heated with waves in the ion cyclotron resonance frequency and electron cyclotron resonance frequency domains. Proto-MPEX has achieved all key parameters (source n e , source T e , source T i , target T e , target T i , target ion flux, and target heat flux) within a factor of 2 of the design requirements of MPEX, albeit not simultaneously. These parameters were achieved with a total installed heating power of 330 kW, which is less than half of the planned heating power in the MPEX (800 kW). An overview of the latest results from Proto-MPEX is given. These results are shown in relationship to the MPEX system goals. Remaining necessary research and development tasks are discussed. The MPEX is currently in the conceptual design phase. Lastly, the status of the design and an overview of the system requirements are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microbial Ecology on Solar Panels in Berkeley, CA, United States

Solar panels can be found practically all over the world and represent a standard surface that can be colonized by microbial communities that are resistant to harsh environmental conditions, including high irradiation, temperature fluctuations and desiccation. These properties make them not only ideal sources of stress-resistant bacteria, but also standard devices to study the microbial communities and their colonization process from different areas of Earth. We report here a comprehensive description of the microbial communities associated with solar panels in Berkeley, CA, United States. Cultivable bacteria were isolated to characterize their adhesive capabilities, and UV- and desiccation-resistance properties. Furthermore, a parallel culture-independent metagenomic and metabolomic approach has allowed us to gain insight on the taxonomic and functional nature of these communities. Metagenomic analysis was performed using the Illumina HiSeq2500 sequencing platform, revealing that the bacterial population of the Berkeley solar panels is composed mainly of Actinobacteria, Bacteroidetes and Proteobacteria, as well as lower amounts of Deinococcus-Thermus and Firmicutes. Furthermore, a clear predominance of Hymenobacter sp. was also observed. A functional analysis revealed that pathways involved in the persistence of microbes on solar panels (i.e., stress response, capsule development, and metabolite repair) and genes assigned to carotenoid biosynthesis were common to all metagenomes. On the other hand, genes involved in photosynthetic pathways and general autotrophic subsystems were rare, suggesting that these pathways are not critical for persistence on solar panels. Metabolomics was performed using a liquid chromatography tandem mass spectrometry (LC-MS/MS) approach. When comparing the metabolome of the solar panels from Berkeley and from Valencia (Spain), a very similar composition in polar metabolites could be observed, although some metabolites appeared to be differentially represented (for example, trigonelline, pantolactone and 5-valerolactone were more abundant in the samples from Valencia than in the ones from Berkeley). Furthermore, triglyceride metabolites were highly abundant in all the solar panel samples, and both locations displayed similar profiles. The comparison of the taxonomic profile of the Californian solar panels with those previously described in Spain revealed striking similarities, highlighting the central role of both selective pressures and the ubiquity of microbial populations in the colonization and establishment of microbial communities.

59 BASIC BIOLOGICAL SCIENCES↗

High field CdS detector for infrared radiation

New and highly sensitive method of detecting infrared irradiation makes possible solid state infrared detector which is more sensitive near room temperature than usual photoconductive low band gap semiconductor devices. Reconfiguration of high field domains in cadmium sulphide crystals provides basis for discovery.

Tyagi, R. C.↗

A Radial Heat Flow Apparatus for Thermal Conductivity Characterisation of Cylindrical Samples

During the last two decades, silicon carbide based ceramic composites (SiC/SiC) have become a candidate material for nuclear fuel cladding, first for advanced nuclear systems, such as the GFR, and recently also as potential replacement material for nuclear fuel cladding in light water reactors. This work is contributing to the General Atomics/Westinghouse led CARAT project. In this frame, the thermal conductivity (TC) of cladding prototype sections are measured both before and after neutron irradiation with the purpose of better understanding the effects of neutron irradiation on the pyrolytic carbon interphase linking the SiC fibres to the SiC matrix. To this end, an apparatus has been designed and built to measure the TC of short cylindrical samples, whose lengths range from 5 to 20 cm, by the radial heat flow method. To avoid oxidation issues, the experiments are carried out in vacuum. Today the most common measurement method used to characterise the TC of materials is the so-called laser-flash technique, whereby a short high intensity laser pulse is shot on one surface of a thin flat sample and the energy transfer through the sample is analysed on the other side. Though much faster and easier to implement than the apparatus presented in this work, laser-flash equipment does have issues when dealing with highly anisotropic materials or capturing shape effects such as those present in large aspect ratio samples such as cladding tube sections. The two aforementioned effects are exactly what the developed equipment has been built to capture. The radial heat flow method is based on the principle of measuring the temperature difference building up through a piece of material as this material acts as a thermal resistance against a known heat flow crossing it. This paper presents a new implementation of one of the classical thermal conductivity measurement techniques. Since the development of the laser-flash method in the sixties, steady-state measurements such as the radial heat flow have fallen in disuse. In this discussion, it is shown that a direct measurement method can be used and even be preferable in the case of highly anisotropic materials such as SiC/SiC composites. The advantage of this experimental setup is that the actual transverse conductivity is obtained, whereas laser-flash measurements yield a response in which both the transverse and axial conductivities are mixed. Further steps of this study will include the measurements of samples irradiated with neutrons in the MITR test-reactor. The aim will be to evidence the role played by the pyrolytic carbon interphase by linking the TC measurements with energy filtered electron microscopy. We would like to acknowledge General Atomics and Westinghouse for their support in the frame of the CARAT research program. Providing us with actual prototype clad sections is a unique opportunity. Furthermore the Swiss CCEM.ch project MeAWaT is acknowledged for partially financing the development of the measurement device. (authors)

36 MATERIALS SCIENCE↗

X-ray Computed Tomography of Irradiated and Unirradiated AGR-3/4 Compacts

X-ray Computed Tomography (XCT) has been utilized to image and characterize compacts from the combined third and fourth irradiation of the Advanced Gas Reactor (AGR) Program, AGR-3/4, fuel. The experiment contained tristructural isotropic (TRISO)-coated fuel particles as well as designed-to-fail (DTF) fuel particles. Two irradiated compacts, representing the lower and higher range of AGR-3/4 burnup (4.85% and 14.92% fissions per initial heavy metal atom FIMA) were examined. These represent the first known highly irradiated TRISO fuel compacts to be examined via X-ray CT. Additionally, two unirradiated compacts from the same production batch as the examined irradiation compacts were also imaged for a baseline comparison. As XCT of irradiated TRISO compacts is not a commonly implemented characterization technique, a significant portion of the report focuses on developed methodology and imaging conditions. A specialized sample shielding device was developed and fabricated specifically to limit received dose to staff during sample preparation for XCT and to minimize excess gamma radiation dose to sensitive electronic components with the utilized X-ray system. Significant penetration through the uranium oxycarbide fuel kernels by significantly hardening the X-ray beam with specialized proprietary filters acquired from Carl Zeiss NTS Ltd. The filter utilized resulted in an average X ray photon energy of ~110 keV which approaches uranium’s K-edge (~115 keV), maximizing penetration for a microfocus X-ray source. The gamma-radiation emitted from the irradiated AGR-3/4 TRISO compacts, has the same properties and mechanisms for interaction with matter as X-rays, thus the detection of gamma-radiation by the utilized X-ray detectors was initially a concern. However, although ?-rays did produce an observable signal on the X-ray detector, its contribution to the overall imaging results appeared negligible upon 3D reconstruction. The neglibile impact on the resulting 3D reconstructed volumes were likely the result of: (1) a significantly lower detection efficiency for ?-rays relative to X-rays; (2) An X-ray flux at the detector several orders of magnitude higher than that of the impinging ?-rays from the irradiated compacts. These results suggest that irradiated compacts with significantly higher radiation fields can be examined in the future if an acceptable route for sample handling and preparation can be determined. Additionally, the 3D imaging results of XCT can provide a valuable means of assessing compacts. While in many ways complimentary to traditional post irradiation examination techniques such as optical ceramography, XCT can provide additional insight into compact features traditionally difficult to discern directly from cross-sectional imaging alone. Preliminary analyses on kernel size, morphology (aspect ratio and sphericity), and kernel orientation were presented. Sphericity, a simple morphological shape descriptor, was utilized to screen for kernel extrusions within the high burnup compact. The number of kernel extrusions identified via XCT represented an approximate two-fold increase from the quantity of extruded particles observed (via optical ceramography) in adjacent compacts from the same irradiation capsule. While numerical analysis of the compact datasets was highly preliminary, initial results show promise for providing complimentary metrics to current AGR-3/4 PIE and potentially additional insight into the processes driving TRISO fuel degradation during reactor operation. Additional analyses to be performed at a later date include a more detailed examination of kernel size, kernel sphericity (and observed kernel extrusions), and sphericity. Given all particles can be observed in a single data volume possible correlation of spatial position with observed kernel features will also be made at a later date.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of TiO{sub 2} and TiO{sub 2}/Au nanoparticles as a Potential Radiosensitizers by Decomposition of Methylene Blue

Nanomaterials are constantly used in several applications of science and engineering. Nanoparticles are currently utilized in computer circuits, clothes, luminescent devices, catalysis, medicine, among many others uses. In the clinical field nanomaterials have become an innovative alternative for early diagnosis and treatment of a significant number of medical conditions. Nanoparticles can be utilized in applications ranging from contrast agents for imaging purposes to carriers for drug delivery in cancerous tumors. The use of nanoparticles made of high atomic number elements as noble metals, is becoming an attractive approach for enhancing the radiation dose delivered to a tissue during radiation therapy. The enhancement effect that makes the cells more sensitive to radiation is known as radiosensitization. Materials such as gold (Au) and titanium dioxide (TiO{sub 2}) at the nanoscale have become promising radiosensitizers. When TiO{sub 2} is irradiated with high energy photons, electron-holes are created within the material. This species interacts with surrounding medium generating reactive oxygen species (ROS). ROS create a toxic environment for cancerous cells, ultimately causing their death. On the other hand gold has a different interaction with ionizing radiation. Upon radiation, gold releases a spray of secondary products such as photoelectrons, auger electrons, and characteristic X-rays. The energy created by the escaping electrons leads to DNA strands breaks in the cells causing their death. Therefore, if these nanoparticles are initially accumulated in the tissue to be treated, the dose delivered during radiation therapy is amplified. This represents a synergistic approach to enhance radiation therapy while substantially reducing side effects. Radiosensitization by nanoparticles often depends on their particle size, morphology and synthesis route. The most commonly used methods to synthesize metallic nanoparticles such as gold involves chemical reduction of a metal precursor. In this case, reducing agents are used in order to transform the metallic ions to metal atoms that will subsequently coalesce and grow to form the nanoparticles . Nevertheless there are alternative methods that do not require a chemical reducing agent. Radiation synthesis is one of those processes. The interaction of ionizing radiation with an aqueous solution containing a metal precursor, leads to a phenomena known as radiolysis of water. Radiolysis of water produces chemical species such as solvated electrons (e{sup -}{sub aq}), and hydrogen atoms (H{sup +}). These species are strong reducing agents that bring the metal ions existing in solution into stable metal atoms that will form nanoparticles. Radiation synthesis is a novel method that offers significant advantages over conventional approaches such as wet chemistry routes. In this approach, no further chemical reducing agents are needed, thus it does not generate byproducts that may affect the nanoparticles properties. This is particularly important in medical applications. Furthermore, this technique is designed to work at room temperature and under atmospheric pressures. Nonetheless the most outstanding feature of radiation synthesis is the possibility to control the particle size and size distribution. This route allows for narrow particle size distributions with size ranging from 2 to 30 nm. Furthermore, the availability of different ionizing radiation producing devices such as synchrotrons, X-ray irradiators, and gamma irradiators enables the possibility of manufacturing nanomaterials under various conditions. In this work, Au nanoparticles were deposited onto TiO{sub 2} using the radiation synthesis method. In addition, the radiosensitization characteristics of TiO{sub 2} and TiO{sub 2}/Au nanoparticles were evaluated through the decomposition of the organic dye Methylene Blue (MB). In order to analyze the degradation of the dye the TiO{sub 2} and TiO{sub 2}/Au nanoparticles were placed in an aqueous solution along with MB and subjected to X-ray irradiation. The samples were irradiated for 30 and 60 minutes. The degradation of the MB after irradiation in the presence and absence of the nanomaterials was measured by UV-Vis spectroscopy following the decrease in the absorbance of the dye at 664 nm. (authors)

36 MATERIALS SCIENCE↗

Radiation Hardened Electronics Destined For Severe Nuclear Reactor Environments

Post nuclear accident conditions represent a harsh environment for electronics. The full station blackout experience at Fukushima shows the necessity for emergency sensing capabilities in a radiation-enhanced environment. This NEET (Nuclear Energy Enabling Technologies) research project developed radiation hardened by design (RHBD) electronics using commercially available technology that employs commercial off-the-shelf (COTS) devices and present generation circuit fabrication techniques to improve the total ionizing dose (TID) hardness of electronics. Such technology not only has applicability to severe accident conditions but also to facilities throughout the nuclear fuel cycle in which radiation tolerance is required. For example, with TID tolerance to megarads of dose, electronics could be deployed for long-term monitoring, inspection and decontamination missions. The present work has taken a two-pronged approach, specifically, development of both board and application-specific integrated circuit (ASIC) level RHBD techniques. The former path has focused on TID testing of representative microcontroller ICs with embedded flash (eFlash) memory, as well as standalone flash devices that utilize the same fabrication technologies. The standalone flash devices are less complicated, allowing better understanding of the TID response of the crucial circuits. Our TID experiments utilize biased components that are in-situ tested, and in full operation during irradiation. A potential pitfall in the qualification of memory circuits is the lack of rigorous testing of the possible memory states. For this reason, we employ test patterns that include all ones, all zeros, a checkerboard of zeros and ones, an inverse checkerboard, and random data. With experimental evidence of improved radiation response for unbiased versus biased conditions, a demonstration-level board using the COTS devices was constructed. Through a combination of redundancy and power gating, the demonstration board exhibits radiation resilience to over 200 krad. Furthermore, our ASIC microprocessor using RHBD techniques was shown to be fully functional after an exposure of 2.5 Mrad whereas the COTS microcontroller units failed catastrophically at <100 krad. The methods developed in this work can facilitate the long-term viability of radiation-hard robotic systems, thereby avoiding obsolescence issues. As a case in point, the nuclear industry with its low purchasing power does not drive the semiconductor industry strategic plans, and the rapid advancements in electronics technology can leave legacy systems stranded.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high-resolving-power x-ray spectrometer for the OMEGA EP Laser (invited)

A high-resolving-power x-ray spectrometer has been developed for the OMEGA EP Laser System based on a spherically bent Si [220] crystal with a radius of curvature of 330 mm and a Spectral Instruments (SI) 800 Series charge-coupled device. The instrument measures time-integrated x-ray emission spectra in the 7.97- to 8.11-keV range, centered on the Cu K{sub α1} line. To demonstrate the performance of the spectrometer under high-power conditions, K{sub α1,2} emission spectra were measured from Cu foils irradiated by the OMEGA EP laser with 100-J, 1-ps pulses at focused intensities above 10{sup 18} W/cm{sup 2}. The ultimate goal is to couple the spectrometer to a picosecond x-ray streak camera and measure temperature-equilibration dynamics inside rapidly heated materials. The plan for these ultrafast streaked x-ray spectroscopy studies is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Failures Of CMOS Devices At Low Radiation-Dose Rates

Method for obtaining approximate failure-versus-dose-rate curves derived from experiments on failures of SGS 4007 complementary metal oxide/semiconductor (CMOS) integrated circuits irradiated by Co60 and Cs137 radioactive sources.

Goben, Charles A.↗