Search NASA⌕ Search

SEARCH · Search NASA

Results for “LAWRENCE LIVERMORE LABORATORY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Integral Experiment Validation of Hafnium with TEX-HEU and TEX-Hf [Slides]

Lead by Lawrence Livermore National Laboratory under the U.S. Department of Energy's Nuclear Criticality Safety Program. The goal of TEX is to provide integral benchmark experiments than span the entire neutron energy spectrum and incorporate high-priority materials. TEX includes two test bed configurations providing a baseline for comparison to better understand the contribution of additional materials

Highly Enriched Uranium↗

AI-Driven Accelerated Inclusion Analysis for Energy Efficient Steelmaking (Final CRADA Report)

This was a collaborative effort between Lawrence Livermore National Security, LLC (LLNS) as manager and operator of Lawrence Livermore National Laboratory (LLNL) and ArcelorMittal USA Research LLC (“ArcelorMittal” as the Participant), to use scanning electron microscopy (SEM) images, computer vision and machine learning methods, and high-performance computing to accelerate the inclusion analysis process of liquid steel so that new methods can be used for near-real time process control on the shop floor.

36 MATERIALS SCIENCE↗

Preparing California’s Cap-and-Trade Program for 2045: Integrating Carbon Dioxide Removal

To meet California’s legislatively mandated 2045 carbon neutrality target (AB 1279, Muratsuchi), analyses from the California Air Resources Board (CARB) and Lawrence Livermore National Laboratory (LLNL) have shown that carbon dioxide removal—activities that permanently remove carbon dioxide (CO 2 ) from the atmosphere—will be necessary to remove greenhouse gas emissions that are otherwise too costly or difficult to reduce. This policy brief explores the policy, legal, and technical considerations for integrating carbon dioxide removal into the Cap-and-Trade Program.

54 ENVIRONMENTAL SCIENCES↗

Efficient screening of rare large pit anomalies on polished surfaces using a minimalist sampling scheme

Lawrence Livermore National Laboratory (LLNL) has made significant strides in generating clean energy through its inertial confinement fusion (ICF) experiments. These experiments rely on high-density carbon (HDC) coated shells to encapsulate the fusion fuel. The success of these experiments is heavily dependent on the surface quality of these shells, as even minor imperfections, such as deep pits, can negatively impact fusion yield. Ensuring the required smoothness involves an extensive surface-finishing process that spans approximately 20 stages, making it both time-intensive and resource-demanding. A critical challenge in this process is the need for high-resolution scans to detect rare deep pits, which can be costly and impractical if performed on every shell. This highlights the necessity of developing more efficient scanning methods to optimize time and cost without compromising accuracy. To address these challenges, we introduce a novel approach that employs the multivariate Dvoretzky–Kiefer–Wolfowitz (DKW) inequality to provide a probabilistic upper bound on the error in estimating pit distribution characteristics via a Kernel Density Estimator (KDE). This error bound enables efficient and reliable estimation of pit distribution characteristics at a specified statistical confidence level using a minimal number of surface scans. The integrated DKW-KDE approach was validated through surface-finishing experiments across two batches of HDC-coated shells, demonstrating consistent and robust performance across multiple stages of the surface-finishing experiments. The validation studies suggest that the integrated DKW-KDE approach achieves comparable accuracy in estimating the risk of deleterious large pits with six scans, thus conserving time and resources. Further evaluations show that performance remains consistent across batches and over multiple polishing stages. In conclusion, based on these findings, one can leverage the minimal-scan insights to strategically improve the bottleneck inspection process, thus enhancing the productivity and quality of shell polishing and similar challenging manufacturing processes.

Inertial confinement fusion↗

Rapid, absolute calibration of x-ray filters employed by laser-produced plasma diagnostics

The Electron Beam Ion Trap (EBIT) facility at the Lawrence Livermore National Laboratory is being used to absolutely calibrate the transmission efficiency of x-ray filters employed by diodes and spectrometers used to diagnose laser-produced plasmas. EBIT emits strong, discrete monoenergetic lines at appropriately chosen x-ray energies. X rays are detected using the high resolution EBIT Calorimeter Spectrometer (ECS), developed for LLNL at the NASA/Goddard Space Flight Center. X-ray filter transmission efficiency is determined by dividing the x-ray counts detected when the filter is in the line of sight by those detected when out of the line of sight. Verification of filter thickness can be completed in only a few hours, and absolute efficiencies can be calibrated in a single day over a broad range from about 0.1 to 15 keV. The EBIT calibration lab has been used to field diagnostics (e.g., the OZSPEC instrument) with fully calibrated x-ray filters at the OMEGA laser. Extensions to use the capability for calibrating filter transmission for the DANTE instrument on the National Ignition Facility are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NDCX-II PULSED POWER SYSTEM AND INDUCTION CELLS

The Heavy Ion Fusion Science Virtual National Laboratory (HIFS-VNL) is currently finalizing the design of NDCX-II, the second phase of the Neutralized Drift Compression Experiment, which will use an ion beam to explore Warm Dense Matter (WDM) and Inertial Fusion Energy (IFE) target hydrodynamics. The ion induction accelerator will include induction cells and Blumleins from the decommissioned Advanced Test Accelerator (ATA) at Lawrence Livermore National Laboratory (LLNL). A test stand has been built at Lawrence Berkeley National Laboratory (LBNL) to test refurbished ATA induction cells and pulsed power hardware for voltage holding and ability to produce various compression and acceleration waveforms. The performance requirements, design modifications, and test results will be presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of the Lawrence Livermore Microbal Detection Array at the Statens Serum Institut CRADA No. TC02189

This was a collaborative effort between Lawrence Livermore National Security, LLC as manager and operator of Lawrence Livermore National Laboratory (LLNL) and Statens Serum Institut to evaluate and transition the Lawrence Livermore Microarray Detection Array (LLMDA) analysis software package, the Composite Likelihood Maximization method (CLiMax) to the SSI. The SSI is a public enterprise under the Danish Ministry of Health that operates a microbiology reference laboratory for the Danish population and analyzes tens to thousands of human clinical samples annually. SSI has been collaborating with the LLNL team for several years to use the LLMDA to analyze viral and bacterial infections from human clinical samples. The collaboration has resulted in two joint publications thus far, describing improvements to LLMDA sample preparation, and the utility of the LLMDA for detecting emerging viruses in clinical samples. Under our previous collaboration, SSI has performed LLMDA experiments at their facility and then transferred the raw LLMDA data to LLNL for analysis. SSI had purchased LLMDA microarrays directly from the manufacturer, Roche NimbleGen. The main purpose of the current collaboration was to adapt the CLiMax analysis software so that it could run on a computer located at SSI. Additional effort was budgeted for LLNL staff to assist SSI with the transition and the operation of the software. The primary deliverable is the CLiMax software, installed on a computer at SSI.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation of the Lawrence Livermore Microbal Detection Array at the Statens Serum Institut

This was a collaborative effort between Lawrence Livermore National Security, LLC as manager and operator of Lawrence Livermore National Laboratory (LLNL) and Statens Serum Institut to evaluate and transition the Lawrence Livermore Microarray Detection Array (LLMDA) analysis software package, the Composite Likelihood Maximization method (CLiMax) to the SSI. The SSI is a public enterprise under the Danish Ministry of Health that operates a microbiology reference laboratory for the Danish population and analyzes tens to thousands of human clinical samples annually. SSI has been collaborating with the LLNL team for several years to use the LLMDA to analyze viral and bacterial infections from human clinical samples. The collaboration has resulted in two joint publications thus far, describing improvements to LLMDA sample preparation, and the utility of the LLMDA for detecting emerging viruses in clinical samples.

59 BASIC BIOLOGICAL SCIENCES↗

High-resolution x-ray spectroscopy with the EBIT Calorimeter Spectrometer

The EBIT Calorimeter Spectrometer (ECS) is a production-class 36 pixel x-ray calorimeter spectrometer that has been continuously operating at the Electron Beam Ion Trap (EBIT) facility at Lawrence Livermore National Laboratory for almost 2 years. The ECS was designed to be a long-lifetime, turn-key spectrometer that couples high performance with ease of operation and minimal operator intervention. To this end, a variant of the Suzaku/XRS spaceflight detector system has been coupled to a low-maintenance cryogenic system consisting of a long-lifetime liquid He cryostat, and a closed cycle, {sup 3}He pre-cooled adiabatic demagnetization refrigerator. The ECS operates for almost 3 weeks between cryogenic servicing and the ADR operates at 0.05 K for more than 60 hours between automatic recycles under software control. Half of the ECS semiconductor detector array is populated with mid-band pixels that have a resolution of 4.5 eV FWHM, a bandpass from 0.05-12 keV, and a quantum efficiency of 95% at 6 keV. The other half of the array has thick HgTe absorbers that have a bandpass from 0.3 to over 100 keV, an energy resolution of 33 eV FWHM, and a quantum efficiency of 32% at 60 keV. In addition, the ECS uses a real-time, autonomous, data collection and analysis system developed for the Suzaku/XRS instrument and implemented in off-the-shelf hardware for the ECS. Here we will discuss the performance of the ECS instrument and its implementation as a turnkey cryogenic detector system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗