Search NASA⌕ Search

SEARCH · Search NASA

Results for “LED Lighting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

SU-D-213-05: Design, Evaluation and First Applications of a Off-Site State-Of-The-Art 3D Dosimetry System

Purpose: To design, construct and commission a prototype in-house three dimensional (3D) dose verification system for stereotatic body radiotherapy (SBRT) verification at an off-site partner institution. To investigate the potential of this system to achieve sufficient performance (1mm resolution, 3% noise, within 3% of true dose reading) for SBRT verification. Methods: The system was designed utilizing a parallel ray geometry instigated by precision telecentric lenses and an LED 630nm light source. Using a radiochromic dosimeter, a 3D dosimetric comparison with our gold-standard system and treatment planning software (Eclipse) was done for a four-field box treatment, under gamma passing criteria of 3%/3mm/10% dose threshold. Post off-site installation, deviations in the system’s dose readout performance was assessed by rescanning the four-field box irradiated dosimeter and using line-profiles to compare on-site and off-site mean and noise levels in four distinct dose regions. As a final step, an end-to-end test of the system was completed at the off-site location, including CT-simulation, irradiation of the dosimeter and a 3D dosimetric comparison of the planned (Pinnacle{sup 3}) to delivered dose for a spinal SBRT treatment(12 Gy per fraction). Results: The noise level in the high and medium dose regions of the four field box treatment was relatively 5% pre and post installation. This reflects the reduction in positional uncertainty through the new design. This At 1mm dose voxels, the gamma pass rates(3%,3mm) for our in-house gold standard system and the off-site system were comparable at 95.8% and 93.2% respectively. Conclusion: This work will describe the end-to-end process and results of designing, installing, and commissioning a state-of-the-art 3D dosimetry system created for verification of advanced radiation treatments including spinal radiosurgery.

60 APPLIED LIFE SCIENCES↗

InGaN nanoinclusions in an AlGaN matrix

GaN-based structures with InGaN quantum dots in the active region emitting in the near-ultraviolet region are studied. In this study, two types of structures, namely, with InGaN quantum dots in a GaN or AlGaN matrix, are compared. Photoluminescence spectra are obtained for both types of structures in a temperature range of 80-300 K and at various pumping densities, and electroluminescence spectra are obtained for light-emitting (LED) structures with various types of active region. It is shown that the structures with quantum dots in the AlGaN matrix are more stable thermally due to the larger localization energy compared with quantum dots in the GaN matrix. Due to this, the LED structures with quantum dots in an AlGaN matrix are more effective.

36 MATERIALS SCIENCE↗

Diversity of Properties of Device Structures Based on Group-III Nitrides, Related to Modification of the Fractal-Percolation System

A fractal-percolation system that includes extended defects and random fluctuations in the alloy composition is formed during the growth of device structures based on Group-III nitrides. It is established that the specific features of this system are determined not only by the growth conditions. It is shown that the diversity of the electrical and optical properties of InGaN/GaN LEDs (light-emitting diodes) emitting at wavelengths of 450–460 and 519–530 nm, as well as that of the electrical properties of AlGaN/GaN HEMT (high-electron-mobility transistor) structures, is due to modification of the properties of the fractal-percolation system both during the growth process and under the action of the injection current and irradiation. The influence exerted by these specific features on the service life of light-emitting devices and on the reliability of AlGaN/GaN HEMT structures is discussed.

36 MATERIALS SCIENCE↗

Investigation into the Distribution of Built-in Electric Fields in LED Heterostructures with Multiple GaN/InGaN Quantum Wells by Electroreflectance Spectroscopy

Electric-field nonuniformity in the active region of a LED (light-emitting diode) heterostructure based on five identical GaN/InGaN quantum wells is investigated by the electroreflectance method. The energies of band-to-band transitions in the quantum wells and barriers are determined from the analysis of electroreflectance spectra using the Kramers–Kronig transforms. The procedure for estimating the electric-field strength in separate quantum wells of the active region by the position of spectral lines is proposed. It is found that the energies of the main transition in quantum wells of the active region with zero bias of the p–n junction differ by a magnitude on the order of 140 meV, which corresponds to a difference in the electric-field strengths of 0.78 MV/cm. It is shown that the nonuniformity of the electric field in the active region depends on the p–n junction bias.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Facility Energy Decision System (FEDS) version 7.0

Designed for building energy managers, utilities and firms providing energy services, FEDS provides a comprehensive and user-friendly method for users to quickly and accurately identifying energy conversion and end-use technology improvements that offer maximum savings in energy usage and cost. FEDS enables the user to assess energy efficiency and consumption, identify retrofit opportunities, select minimum life cycle costs, determine payback, and prioritize investments in energy efficiency retrofit projects for multiple or single buildings across a particular site. As part of the life-cycle cost optimization it also considers several options for partial or complete abandonment of central energy plants including: individual technologies dropping off a thermal loop, a loop and all technologies dropping off a central plant, and all technologies and loops dropping off a central plant resulting in its complete abandonment. Improvements in release 7.0 include: FEDS 7.0 is now a full hourly simulation model (runs every hour of the year as opposed to the previous simplified hourly approach which ran 9 24-hour periods to represent each month). Enhanced building operation and occupancy modeling; New HVAC technology options (VAV, Economizers, Demand Controlled Ventilation, Terminal Reheat, Subcool Dehumidification); Additional chiller types; New lighting technologies (LED, Halogen, Induction, additional fluorescent options); Completely updated retrofit cost and performance data; Regional cost data tied to zip code (previously applied state level averages); Updated and enhanced reporting capabilities; and New pier floor model

Dirks, James↗

Toward white light emission from plasmonic-luminescent hybrid nanostructures

We study the light emission of plasmonic-luminescent hybrid nanostructures consisting of Ag nanoparticles (NPs) embedded in europium oxide (EuO X ). The Ag NPs present a bidimensional organization in the nanostructures and they optically behave as oblate spheroids. The photoluminescence (PL) spectral response of the nanostructures evolves from a narrow red emission characteristic of Eu 3+ ions in absence of Ag NPs to a broad blue-green emission band associated with Eu 2+ ions when the layer of Ag NPs is present. This behavior is not related to a change in the Eu 2+ /Eu 3+ ratio, which is verified by compositional analysis. Instead, a detailed investigation of the PL emission of the nanostructures suggests that the coupling of the Ag NPs to the Eu 2+ ions present in the EuO X layer, which manifests itself in an efficient sensitization of these ions, enhances their broad visible emission. In particular, the longitudinal mode of the Ag NPs surface plasmon is considered to be responsible for the efficient energy transfer for the non-normal incidence excitation PL configuration used. Finally, the use of a capping amorphous Al 2 O 3 layer allows improving the robustness of hybrid nanostructures and further enhances their PL emission. These findings provide a new path to actively control the selective excitation of Eu 2+ and Eu 3+ ions via a controlled coupling with the surface plasmon resonance modes of the Ag NPs and points to these nanostructures as promising building blocks for the development of integrable white light sources.

36 MATERIALS SCIENCE↗

Modeling City Building Stock for Large-Scale Energy Efficiency Improvements using CityBES

Buildings in San Francisco consumed 52% of total primary energy. Improving building energy efficiency is one of the key strategies cities are adopting towards their energy and climate goals. Urban building energy models (UBEM) can support city managers to evaluate and prioritize energy conservation measures for investment and to design effective incentive and rebate programs. This paper introduces methods to develop a standardized dataset of city building stock, and it demonstrates the use of a UBEM tool, City Building Energy Saver (CityBES), for an urban-scale energy retrofit analysis of building stock in the city of San Francisco. CityBES is an open web-based data and computing platform providing city-scale building energy modeling and performance visualization and benchmarking. CityBES utilizes an international standard CityGML to represent the three-dimensional building stock in cities. As an application example, 940 office and retail buildings in six districts of northeast San Francisco were modeled and analyzed with CityBES to evaluate energy savings for five selected measures. The analysis found that replacing existing lighting with LED and adding an air economizer to HVAC systems are cost-effective measures with combined savings per building between 17% to 31%. The CityBES retrofit analysis feature does not require users to have deep knowledge of building systems or building energy models, which helps overcome barriers for city managers and their consultants to adopt UBEM.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance House -- A Cold Climate Challenge Home

Working with builder partners on a test homes allows for vetting of whole-house building strategies to eliminate any potential unintended consequences prior to implementing these solution packages on a production scale. To support this research, CARB partnered with Preferred Builders Inc. on a high-performance test home in Old Greenwich, CT. The philosophy and science behind the 2,700 ft2 'Performance House' was based on the premise that homes should be safe, healthy, comfortable, durable, efficient, and adapt with the homeowners. The technologies and strategies used in the 'Performance House' were not cutting-edge, but simply 'best practices practiced'. The focus was on simplicity in construction, maintenance, and operation. When seeking a 30% source energy savings targets over a comparable 2009 IECC code-built home in the cold climate zone, nearly all components of a home must be optimized. Careful planning and design are critical. To help builders and architects seeking to match the performance of this home, a step-by-step guide through the building shell components of DOE's Challenge Home are provided in a pictorial story book. The end result was a DOE Challenge Home that achieved a HERS Index Score of 20 (43 without PV, the minimum target was 55 for compliance). This home was also awarded the 2012 HOBI for Best Green Energy Efficient Home from the Home Builders & Remodelers Association of Connecticut.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance House: A Cold Climate Challenge Home, Old Greenwich, Connecticut (Fact Sheet)

By working with builder partners on test homes, researchers from the U.S. Department of Energy's Building America program can vet whole-house building strategies and avoid potential unintended consequences of implementing untested solution packages on a production scale. To support this research, Building America team Consortium for Advanced Residential Buildings (CARB) partnered with Preferred Builders Inc. on a high-performance test home in Old Greenwich, Connecticut. The philosophy and science behind the 2,700 ft2 "Performance House" was based on the premise that homes should be safe, healthy, comfortable, durable, efficient, and adaptable to the needs of homeowners. The technologies and strategies used in the "Performance House" were best practices rather than cutting edge, with a focus on simplicity in construction, maintenance, and operation. Achieving 30% source energy savings compared with a home built to the 2009 International Energy Conservation Code in the cold climate zone requires that nearly all components and systems be optimized. Careful planning and design are critical. The end result was a DOE Challenge Home that achieved a Home Energy Rating System (HERS) Index Score of 20 (43 without photovoltaics [PV]).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CALiPER Application Summary Report 17. LED AR111 and PAR36 Lamps

Report 17 analyzes the performance of a group of six LED products labeled as AR111 lamps. Results indicate that this product category lags behind other types of directional LED lamps but may perform acceptably in some applications and provide some energy savings.

caliper↗

CALiPER Application Summary Report 15: LED Floodlights

This report analyzes the independently tested performance of 10 LED floodlights purchased between August and December 2011. The group included a wide range of products, both physically and in performance characteristics, which mirrors the nearly indefinite range of conventional luminaires designated as floodlights.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CALiPER Application Summary Report 14: LED Downlight Retrofit Units

This CALiPER report analyzes the independently tested performance of 11 anonymously purchased LED downlight retrofit units—referred to as the Series 14 products. All the units were tested in a 6-inch insulation contact (IC) rated downlight housing mounted in a 24-inch by 24-inch insulated enclosure.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Performance House—A Cold Climate Challenge Home

Working with builder partners on test homes allows for vetting of whole-house building strategies to eliminate any potential unintended consequences prior to implementing these solution packages on a production scale. To support this research, CARB partnered with Preferred Builders Inc. on a high-performance test home in Old Greenwich, CT. The philosophy and science behind the 2,700 ft 2 "Performance House" was based on the premise that homes should be safe, healthy, comfortable, durable, efficient, and adapt with the homeowners. The technologies and strategies used in the "Performance House" were not cutting-edge, but simply "best practices practiced". The focus was on simplicity in construction, maintenance, and operation. When seeking a 30% source energy savings targets over a comparable 2009 IECC code-built home in the cold climate zone, nearly all components of a home must be optimized. Careful planning and design are critical. To help builders and architects seeking to match the performance of this home, a step-by-step guide through the building shell components of DOE's Challenge Home are provided in a pictorial story book. The end result was a DOE Challenge Home that achieved a HERS Index Score of 20 (43 without PV, the minimum target was 55 for compliance). This home was also awarded the 2012 HOBI for Best Green Energy Efficient Home from the Home Builders & Remodelers Association of Connecticut.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2015 Project Portfolio: Solid-State Lighting

Overview of SSL projects currently funded by DOE, and those previously funded but since completed. Each profile includes a brief technical description, as well as information about project partners, funding, and the research period. This report is updated annually.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CALiPER Report 20.3: Robustness of LED PAR38 Lamps

A small sample of each of the CALiPER Application Summary Report 20 PAR38 lamp types underwent stress testing that included substantial temperature and humidity changes, electrical variation, and vibration. The results do not directly address expected lifetime, but can be compared with one another, as well as with benchmark conventional products, to assess the relative robustness of the product designs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗