Search NASA⌕ Search

SEARCH · Search NASA

Results for “Liquid sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Status of SRNL radiological field lysimeter experiment-Year 1

The Savannah River National Laboratory (SRNL) Radiological Field Lysimeter Experiment is a one-of-a-kind field facility designed to study radionuclide geochemical processes at a larger spatial scale (from grams to tens of kilograms sediment) and temporal scale (from months to 10 years) than is readily afforded through laboratory studies. The lysimeter facility is intended to capture the natural heterogeneity of moisture and temperature regimes in the vadose zone, the unsaturated subsurface region between the surface soil and the underlying aquifer. The 48 lysimeter columns, which contain various radionuclides (and stable iodine), were opened to rainfall infiltration on July 5, 2012. The objective of this report is to provide a status of the lysimeter facility operations and to compile data collected during FY13, including leachate volume, rainfall, and soil moisture and temperature in situ probe data. Radiological leachate data are not presented in this document but will be the subject of a separate document.1 Leachate samples were collected quarterly and shipped to Clemson University for radiological analyses. Rainfall, leachate volume, moisture and temperature probe data were collected continuously. During operations of the facility this year, there were four safety or technical concerns that required additional maintenance: 1) radioactivity was detected in one of the overflow bottles (captured water collected from the secondary containment that does not come in contact with the radiological source material); 2) rainwater accumulated within the sample-bottle storage sheds; 3) overflow containers collected more liquid than anticipated; and 4) significant spider infestation occurred in the sample-bottle storage sheds. To address the first three concerns, each of the lysimeter columns was re-plumbed to improve and to minimize the number of joint unions. To address the fourth concern regarding spiders, new sample-bottle water sheds were purchased and a pest control program was established. During this retrofit, the lysimeters were temporarily capped (covered to preclude additional water from entering lysimeter columns) for about two months (except the four Tc-cementitious containing lysimeters, which remain capped). At a later date, data summarized in this report will be combined with the leachate radionuclide concentration data that are presently being analyzed. Together, these data can be numerically modeled to provide bench-marking information, to test hypotheses regarding hydrogeochemical conceptual models, and to estimate effective transport parameters under field conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Partitioning of oxygen isotopes during the aqueous solvation of nitric acid

Mixtures of water and inorganic acids show differences in isotopic composition between the vapor and liquid phases, reportedly even at an azeotrope. A recent reactive azeotropy analysis rationalized this by allowing for differences in stable isotope composition between bound solvation complexes and the bulk liquid. In this study, a mixture of water and nitric acid was examined experimentally to determine whether or not significant differences in stable isotope composition exist between bound solvation complexes and the bulk solution. A Rayleigh distillation was conducted using a solution of nitric acid and water. During the distillation, it was expected that bulk water would be vaporized first while (bound) water involved with hydrating the acid would be vaporized at later times along with the acid. Samples of both distillate and residual liquid were collected over time intervals and analyzed to determine oxygen and nitrogen stable isotope composition using isotope ratio mass spectrometry. Comparative samples were collected from the distillation of water alone. The measured oxygen fractionation factors suggest that the acid is preferentially hydrated with 18 O-enriched water, compared to the unbound, or bulk, water. Preferential coordination of 18 O-enriched water with the dissolved acid is consistent with heavier water forming stronger bonds relative to light water. Here, the results imply that isotope-dependent partitioning between bulk solvent and dissolved complexes may prove necessary in developing accurate descriptions of isotope fractionation during vapor-liquid equilibrium.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Type A Verification Report for the High Flux Beam Reactor Stack and Grounds, Brookhaven National Laboratory, Upton, New York

The U.S. Department of Energy (DOE) Order 458.1 requires independent verification (IV) of DOE cleanup projects (DOE 2011). The Oak Ridge Institute for Science and Education (ORISE) has been designated as the responsible organization for IV of the High Flux Beam Reactor (HFBR) Stack and Grounds area at Brookhaven National Laboratory (BNL) in Upton, New York. The IV evaluation may consist of an in-process inspection with document and data reviews (Type A Verification) or a confirmatory survey of the site (Type B Verification). DOE and ORISE determined that a Type A verification of the documents and data for the HFBR Stack and Grounds: Survey Units (SU) 6, 7, and 8 was appropriate based on the initial survey unit classification, the walkover surveys, and the final analytical results provided by the Brookhaven Science Associates (BSA). The HFBR Stack and Grounds surveys began in June 2011 and were completed in September 2011. Survey activities by BSA included gamma walkover scans and sampling of the as-left soils in accordance with the BSA Work Procedure (BNL 2010a). The Field Sampling Plan - Stack and Remaining HFBR Outside Areas (FSP) stated that gamma walk-over surveys would be conducted with a bare sodium iodide (NaI) detector, and a collimated detector would be used to check areas with elevated count rates to locate the source of the high readings (BNL 2010b). BSA used the Mult- Agency Radiation Survey and Site Investigation Manual (MARSSIM) principles for determining the classifications of each survey unit. Therefore, SUs 6 and 7 were identified as Class 1 and SU 8 was deemed Class 2 (BNL 2010b). Gamma walkover surveys of SUs 6, 7, and 8 were completed using a 2X2 NaI detector coupled to a data-logger with a global positioning system (GPS). The 100% scan surveys conducted prior to the final status survey (FSS) sampling identified two general soil areas and two isolated soil locations with elevated radioactivity. The general areas of elevated activity identified were investigated further with a collimated NaI detector. The uncollimated average gamma count rate was less than 15,000 counts per minute (cpm) for the SU 6, 7, and 8 composite area (BNL 2011a). Elevated count rates were observed in portions of each survey unit. The general areas of elevated counts near the Building 801 ventilation and operations and the entry to the Stack were determined to be directly related to the radioactive processes in those structures. To compensate for this radioactive shine, a collimated or shielded detector was used to lower the background count rate (BNL 2011b and c). This allowed the surveyor(s) to distinguish between background and actual radioactive contamination. Collimated gamma survey count rates in these shine affected areas were below 9,000 cpm (BNL 2011a). The average background count rate of 7,500 cpm was reported by BSA for uncollimated NaI detectors (BNL 2011d). The average collimated background ranged from 4,500-6,500 cpm in the westernmost part of SU 8 and from 2,000-3,500 cpm in all other areas (BNL 2011e). Based on these data, no further investigations were necessary for these general areas. SU 8 was the only survey unit that exhibited verified elevated radioactivity levels. The first of two isolated locations of elevated radioactivity had an uncollimated direct measurement of 50,000 cpm with an area background of 7,500 cpm (BNL 2011f). The second small area exhibiting elevated radiation levels was identified at a depth of 6 inches from the surface. The maximum reported count rate of 28,000 cpm was observed during scanning (BNL 2011g). The affected areas were remediated, and the contaminated soils were placed in an intermodal container for disposal. BSA's post-remediation walkover surveys were expanded to include a 10-foot radius around the excavated locations, and it was determined that further investigation was not required for these areas (BNL 2011 f and g). The post-remediation soil samples were collected and analyzed with onsite gamma spectroscopy equipment. These samples were also included with the FSS samples that were analyzed at an offsite facility for the primary radionuclides of concern (ROCs) (i.e., cesium-137, strontium-90, and radium-226). Analysis included full spectrum gamma spectroscopy for all samples. Sr-90 analysis was completed on all samples from SUs 6 and 7. However Sr-90 was only completed on the cores, composites, field blank and duplicate samples in SU 8. Alpha spectroscopy as well as liquid scintillation performed for tritium, carbon-14, and nickel-63 concentrations were completed on the composite samples from SUs 6 and 7. Various cores, composites, and samples from the remediated areas of SU 8 received alpha spectroscopy as well as liquid scintillation analyses for tritium, carbon-14, and nickel-63 to determine respective ROC concentrations (BNL 2011 h, i, and j). BSA submitted the FSS data and analytical results to demonstrate that remediation efforts complied with the specified cleanup goal of less than or equal to 15 millirem per year (mrem/yr) above background to a resident in 50 years (BNL 2011a through j). ORISE has reviewed the project documentation and FSS data for the HFBR Stack and Grounds: SUs 6, 7, and 8. The highest concentrations of the primary ROCs reported were 5.92 picocuries per gram (pCi/g) for Cs-137 and 2.03 pCi/g for Sr-90, with both ROCs having the qualifier for the sample result as less than the minimum detectable activity (MDA). For Ra-226, the highest detected concentration from the FSS data provided was 0.682 pCi/g. Other potential secondary contaminants were below their respective MDAs. Therefore, ORISE is of the opinion that BSA has provided sufficient evidence to demonstrate compliance with the 15 mrem/yr cleanup objectives for the final status survey data provided.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Integrity Assessment of Hanford 242-A Evaporator Facility E-A-1 Re-boiler Vessel via Fluorescein Liquid Tracer Test Methods - 17357

The 242-A Evaporator Facility is critical to the United States Department of Energy's (DOE) Hanford Site clean-up mission due to limited space within the existing Double-Shell Tanks (DSTs) used to store nuclear and chemical waste until future processing. The 242-A Evaporator Facility is currently the sole waste volume reduction process used at Hanford, and the E-A-1 Re-boiler is essential to the Evaporator process. Due to the potential for cross-contamination between the Re-boiler tubes through which waste passes and the tube sheets of uncontaminated steam, an assessment of the Re-boiler vessel's integrity is required for continuing operations of the facility. In order to meet these requirements, an independent integrity assessment was designed to use fluorescein liquid tracer (LT) to verify the leak-tightness of the Re-boiler vessel in accordance with Washington River Protection Solutions, LLC (WRPS) tightness test standards, as well as, the ASME Boiler and Pressure Vessel (B and PV) Code, Section III, Division 1, NB-6300. LT test methodologies were evaluated and determined to be appropriate for a vessel with restricted access, such as the E-A-1 Re-boiler, as it provided the needed sensitivity, reliability, and cost; as well as, exceeded the leak-tightness specifications required by both WRPS and ASME B and PV Code standards. The integrity test requires water laced with fluorescein be circulated through the waste processing loop of the 242-A Evaporator and samples of steam condensate be collected and analyzed for traces of fluorescein to determine leak-tightness. Liquid condensate sampling was conducted prior to and during testing and the samples were analyzed for fluorescein tracer to determine the amount of fluorescein that flowed out of the tubes of the Re-boiler into the steam side of the vessel. Given the established criteria for 'leak-tight,' test results determined that the Re-boiler passed the integrity assessment. After further scrutiny of the 2014 test and data results, it was determined that although the Re-boiler was 'leak-tight,' as established by the test criteria, there was concern of future leakage. The DOE and the DOE Office of River Protection (ORP) requested that WRPS repeat the integrity assessment in two and a half years to determine if the potential leak was growing, which could threaten continuing operations of the 242-A Evaporator. The 2017 test has been redesigned using lessons learned from the 2014 test and was modified to account for ergonomic and safety considerations, ease of repeatability, and accuracy of results. The liquid tracer methodology and test plan developed for the Re-boiler will continue to be implemented in 5 year increments to monitor current and future integrity. The method may also prove useful for other aging components across the Hanford Site, where appropriate. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Online, Absolute Quantitation of Propranolol from Spatially Distinct 20- and 40-μm Dissections of Brain, Liver, and Kidney Thin Tissue Sections by Laser Microdissection–Liquid Vortex Capture–Mass Spectrometry

Here, spatial resolved quantitation of chemical species in thin tissue sections by mass spectrometric methods has been constrained by the need for matrix-matched standards or other arduous calibration protocols and procedures to mitigate matrix effects (e.g., spatially varying ionization suppression). Reported here is the use of laser cut and drop sampling with a laser microdissection-liquid vortex capture electrospray ionization tandem mass spectrometry (LMD-LVC/ESI-MS/MS) system for online and absolute quantitation of propranolol in mouse brain, kidney, and liver thin tissue sections of mice administered with the drug at a 7.5 mg/kg dose, intravenously. In this procedure either 20 μm x 20 μm or 40 μm x 40 μm tissue microdissections were cut and dropped into the flowing solvent of the capture probe. During transport to the ESI source drug related material was completely extracted from the tissue into the solvent, which contained a known concentration of propranolol-d 7 as an internal standard. This allowed absolute quantitation to be achieved with an external calibration curve generated from standards containing the same fixed concentration of propranolold-d 7 and varied concentrations of propranolol. Average propranolol concentrations determined with the laser cut and drop sampling method closely agreed with concentration values obtained from 2.3 mm diameter tissue punches from serial sections that were extracted and quantified by HPLC/ESI-MS/MS measurements. In addition, the relative abundance of hydroxypropranolol glucuronide metabolites were recorded and found to be consistent with previous findings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rates and Mechanisms of Oil Shale Pyrolysis: A Chemical Structure Approach

Three pristine Utah Green River oil shale samples were obtained and used for analysis by the combined research groups at the University of Utah and Brigham Young University. Oil shale samples were first demineralized and the separated kerogen and extracted bitumen samples were then studied by a host of techniques including high resolution liquid-state carbon-13 NMR, solid-state magic angle sample spinning 13C NMR, GC/MS, FTIR, and pyrolysis. Bitumen was extracted from the shale using methanol/dichloromethane and analyzed using high resolution 13C NMR liquid state spectroscopy, showing carbon aromaticities of 7 to 11%. The three parent shales and the demineralized kerogens were each analyzed with solid-state 13C NMR spectroscopy. Carbon aromaticity of the kerogen was 23-24%, with 10-12 aromatic carbons per cluster. Crushed samples of Green River oil shale and its kerogen extract were pyrolyzed at heating rates from 1 to 10 K/min at pressures of 1 and 40 bar and temperatures up to 1000°C. The transient pyrolysis data were fit with a first-order model and a Distributed Activation Energy Model (DAEM). The demineralized kerogen was pyrolyzed at 10 K/min in nitrogen at atmospheric pressure at temperatures up to 525°C, and the pyrolysis products (light gas, tar, and char) were analyzed using 13C NMR, GC/MS, and FTIR. Details of the kerogen pyrolysis have been modeled by a modified version of the chemical percolation devolatilization (CPD) model that has been widely used to model coal combustion/pyrolysis. This refined CPD model has been successful in predicting the char, tar, and gas yields of the three shale samples during pyrolysis. This set of experiments and associated modeling represents the most sophisticated and complete analysis available for a given set of oil shale samples.

Fletcher, Thomas↗

Arsenic uptake in bacterial calcite

Bio-mediated processes for arsenic (As) uptake in calcite were investigated by means of X-ray Diffraction (XRD) and Xray Absorption Spectroscopy (XAS) coupled with X-ray Fluorescence measurements. The environmental bacterial strain Bacillus licheniformis BD5, sampled at the Bullicame Hot Springs (Viterbo, Central Italy), was used to synthesize calcite from As-enriched growth media. Both liquid and solid cultures were applied to simulate planktonic and biofilm community environments, respectively. Bacterial calcite samples cultured in liquid media had an As enrichment factor (Kd) 50 times higher than that from solid media. The XRD analysis revealed an elongation of the crystal lattice along the c axis (by 0.03Å) for biogenic calcite, which likely resulted from the substitution of larger arsenate for carbonate in the crystal. The XAS data also showed a clear difference in the oxidation state of sorbed As between bacterial and abiotic calcite. Abiotic chemical processes yielded predominantly As(V) uptake whereas bacterial precipitation processes led to the uptake of both As(III) and As(V). The presence of As(III) in bacterial calcite is proposed to result from subsequent reduction of arsenate to arsenite by bacterial activities. To the best of our knowledge, this is the first experimental observation of the incorporation of As(III) in the calcite crystal lattice, revealing a critical role of biochemical processes for the As cycling in nature.

59 BASIC BIOLOGICAL SCIENCES↗

Mass Spectrometry-Based High-Throughput Quantification of Bioproducts in Liquid Culture

To meet the ever-increasing need for high-throughput screening in metabolic engineering, information-rich, fast screening methods are needed. Mass spectrometry (MS) provides an efficient and general approach for metabolite screening and offers the capability of characterizing a broad range of analytes in a label-free manner, but often requires a range of sample clean-up and extraction steps. Liquid extraction surface analysis (LESA) coupled MS is an image-guided MS surface analysis approach that directly samples and introduces metabolites from a surface to MS. Here, we combined the advantages of LESA–MS and an acoustic liquid handler with stable isotope-labeled internal standards. This approach provides absolute quantitation of target chemicals from liquid culture-dried droplets and enables high-throughput quantitative screening for microbial metabolites. In this paper, LESA–MS was successfully applied to quantify several different metabolites (itaconic acid, triacetic acid lactone, and palmitic acid) from different yeast strains in different mediums, demonstrating its versatility, accuracy, and efficiency across a range of microbial engineering applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Understanding and controlling low-temperature aging of nanocrystalline materials.

Nanocrystalline copper lms were created by both repetitive high-energy pulsed power, to produce material without internal nanotwins; and pulsed laser deposition, to produce nan- otwins. Samples of these lms were indented at ambient (298K) and cryogenic temperatures by immersion in liquid nitrogen (77K) and helium (4K). The indented samples were sectioned through the indented regions and imaged in a scanning electron microscope. Extensive grain growth was observed in the lms that contained nanotwins and were indented cryogenically. The lms that either lacked twins, or were indented under ambient conditions, were found to exhibit no substantial grain growth by visual inspection. Precession transmission elec- tron microscopy was used to con rm these ndings quantitatively, and show that 3 and 7 boundaries proliferate during grain growth, implying that these interface types play a key role in governing the extensive grain growth observed here. Molecular dynamics sim- ulations of the motion of individual grain boundaries demonstrate that speci c classes of boundaries - notably 3 and 7 - exhibit anti- or a-thermal migration, meaning that their mobilities either increase or do not change signi cantly with decreasing temperature. An in-situ cryogenic indentation capability was developed and implemented in a transmission electron microscope. Preliminary results do not show extensive cryogenic grain growth in indented copper lms. This discrepancy could arise from the signi cant di erences in con g- uration and loading of the specimen between the two approaches, and further research and development of this capability is needed.

Battaile, Corbett Chandler↗

Plasma proteomic biomarkers of physical frailty in heart failure: a propensity score matched discovery-based pilot study

Background: Physical frailty is highly prevalent in heart failure (HF), but we lack an understanding of the underlying pathophysiology. Proteomics evaluation of plasma samples may elucidate potential mechanisms and biomarkers of physical frailty in HF. We aimed to identify plasma proteomic biomarkers that are differentially expressed between physically frail and non physically frail adults with HF. Methods: This was a secondary analysis of a subset of data and plasma samples from a study of frailty among patients with New York Heart Association (NYHA) Functional Classification I-IV HF. Physical frailty was measured using the Frailty Phenotype Criteria. Propensity score matching was used to match pairs of physically frail (n = 20) vs. non-physically frail (n = 20) patients on clinical characteristics. Plasma samples were processed using a sensitive liquid chromatography mass spectrometry platform, utilizing a multiplexed tandem mass tag-labeled quantitative proteomics approach. Differentially expressed proteins were quantified individually using paired t tests with associated log fold change of 0.3 and Fisher’s combined p values. Results: The sample (n = 40) was 62.8±16.9 years old, 58% female, and 55% NYHA Class III/IV. Proteomics analysis revealed 7 proteins differentially expressed using full differential criteria: matrix metalloproteinase-14 was downregulated in frailty, and copine-1, low affinity immunoglobulin gamma Fc region receptor III-A and III-B, probable non-functional immunoglobulin kappa variable 2D-24, glutathione S-transferase Mu 1, and argininosuccinate lyase were upregulated in frailty. Conclusions: Proteomic biomarkers related to the immune system, stress response, and detoxification were differentially expressed between physically frail and non-physically frail adults with HF.

Biomarkers↗

Liquid balance monitoring inside conventional, Retrofit, and bio-reactor landfill cells

Highlights: • The Retrofit, Control, and As-Built cells received 48, 14, and 213 L Mg{sup −1} (liters of liquids per metric ton of waste). • The leachate collection system yielded 60, 57 and 198 L Mg{sup −1} from the Retrofit, Control, and As-Built cells. • The head on liner in all cells was below regulatory limits. • Measured moisture content of the waste samples was consistent with that calculated from accumulated liquid by balance. • The in-place saturated hydraulic conductivity of the MSW was calculated to be in the range of 10{sup −8} to 10{sup −7} m s{sup −1}. - Abstract: The Outer Loop landfill bioreactor (OLLB) in Louisville, KY, USA has been the site of a study to evaluate long-term bioreactor performance at a full-scale operational landfill. Three types of landfill units were studied including a conventional landfill (Control cell), a new landfill area that had an air addition and recirculation piping network installed as waste was being placed (As-Built cell), and a conventional landfill that was modified to allow for liquids recirculation (Retrofit cell). During the monitoring period, the Retrofit, Control, and As-Built cells received 48, 14, and 213 L Mg{sup −1} (liters of liquids per metric ton of waste), respectively. The leachate collection system yielded 60, 57 and 198 L Mg{sup −1} from the Retrofit, Control, and As-Built cells, respectively. The head on liner in all cells was below regulatory limits. In the Control and As-Built cells, leachate head on liner decreased once waste placement stopped. The measured moisture content of the waste samples was consistent with that calculated from the estimate of accumulated liquid by the liquid balance. Additionally, measurements on excavated solid waste samples revealed large spatial variability in waste moisture content. The degree of saturation in the Control cells decreased from 85% to 75%. The degree of saturation increased from 82% to 83% due to liquids addition in the Retrofit cells and decreased back to 80% once liquid addition stopped. In the As-Built cells, the degree of saturation increased from 87% to 97% during filling activities and then started to decrease soon after filling activities stopped to reach 92% at the end of the monitoring period. The measured leachate generation rates were used to estimate an in-place saturated hydraulic conductivity of the MSW in the range of 10{sup −8} to 10{sup −7} m s{sup −1} which is lower than previous reports. In the Control and Retrofit cells, the net loss in liquids, 43 and 12 L Mg{sup −1}, respectively, was similar to the measured settlement of 15% and 5–8% strain, respectively (Abichou et al., 2013). The increase in net liquid volume in the As-Built cells indicates that the 37% (average) measured settlement strain in these cells cannot be due to consolidation as the waste mass did not lose any moisture but rather suggests that settlement was attributable to lubrication of waste particle contacts, softening of flexible porous materials, and additional biological degradation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ice nucleation ability of loess from the northwestern United States

The heterogeneous nucleation of ice processes involving loess particles that influences the formation of mixed-phase clouds are poorly understood. Here, the ice nucleating ability of wind-blown dust or loess accumulated from the past glaciated area was investigated at three temperatures: -26, -30, and -34 °C and at below and above saturation with respect to liquid water conditions. Total six loess samples from different regions across Columbia Basin province, WA, USA were collected, dry dispersed, size-selected at mobility diameter 200 nm, and investigated for their ice nucleation efficiency. To understand the effect of atmospheric processing during long-range transport on their ice nucleating ability, similar experiments were also performed on acid-treated loess samples. Additionally, the ice nucleating properties of Arizona Test Dust (ATD) were investigated as a surrogate for natural mineral dust particles to test the experimental approach. Results show that treated particles have lower ice nucleation efficiency compared to untreated particles at all temperature and saturation with respect to liquid water conditions. Comparison based on ice-active site density ( N s ) metric indicate that loess particles at saturation with respect to liquid water conditions are marginally more efficient than the mineral and soil dust values reported in the literature, but they have lower efficiencies than the predicted N s efficiency of K-feldspar particles at supercooled temperatures greater than -38 °C.

54 ENVIRONMENTAL SCIENCES↗

Development of a low background liquid scintillation counter for a shallow underground laboratory

Pacific Northwest National Laboratory has recently opened a shallow underground laboratory intended for measurement of lowconcentration levels of radioactive isotopes in samples collected from the environment. The development of a low-background liquid scintillation counter is currently underway to further augment the measurement capabilities within this underground laboratory. Liquid scintillation counting is especially useful for measuring charged particle (e.g., B, a) emitting isotopes with no (orvery weak) gamma-ray yields. The combination of high-efficiency detection of charged particle emission in a liquid scintillation cocktail coupled with the low-background environment of an appropriately-designed shield located in a clean underground laboratory provides the opportunity for increased-sensitivity measurements of a range of isotopes. To take advantage of the 35-meter water-equivalent overburden of the underground laboratory, a series of simulations have evaluated the instrumental shield design requirements to assess the possible background rate achievable. This report presents the design and background evaluation for a shallow underground, low background liquid scintillation counter design for sample measurements.

liquid scintillation counting↗

Production of Gas-Phase Uranium Fluoroanions Via Solubilization of Uranium Oxides in the [1-Ethyl-3-Methylimidazolium]{sup +}[F(HF){sub 2.3}]{sup −} Ionic Liquid

A new methodology for gas-phase uranium ion formation is described in which UO{sub 2} is dissolved in neat N-ethyl,N′-methylimidazolium fluorohydrogenate ionic liquid [EMIm{sup +}][F(HF){sub 2.3}{sup −}], yielding a blue-green solution. The solution was diluted with acetonitrile and then analyzed by electrospray ionization mass spectrometry. UF{sub 6}{sup −} (a U(V) species) was observed at m/z = 352, and other than cluster ions derived from the ionic liquid, nothing else was observed. When the sample was analyzed using infusion desorption chemical ionization, UF{sub 6}{sup −} was the base peak, and it was accompanied by a less intense UF{sub 5}{sup −} that most likely was formed by elimination of a fluorine radical from UF{sub 6}{sup −}. Formation of UF{sub 6}{sup −} required dissolution of UO{sub 2} followed by or concurrent with oxidation of uranium from the + 4 to the + 5 state and finally formation of the fluorouranate. Dissolution of UO{sub 3} produced a bright yellow solution indicative of a U(VI) species; however, electrospray ionization did not produce abundant U-containing ions. The abundant UF{sub 6}{sup −} provides a vehicle for accurate measurement of uranium isotopic abundances free from interference from minor isotopes of other elements and a convenient ion synthesis route that is needed gas-phase structure and reactivity studies like infrared multiphoton dissociation and ion-molecule dissociation and condensation reactions. The reactive fluorohydrogenate ionic liquid may also enable conversion of uranium in oxidic matrices into uranium fluorides that slowly oxidize to uranyl fluoride under ambient conditions, liberating the metal for facile measurement of isotope ratios without extensive chemical separations. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of Flow-Injection Tandem Mass Spectrometry for Rapid and High-Throughput Quantitative Determination of B-Vitamins in Nutritional Supplements

The use of flow-injection electrospray ionization tandem mass spectrometry for rapid and high-throughput mass spectral analysis of selected B-vitamins, viz. B1, B2, B3, B5, and B6, in nutritional formulations was demonstrated. A simple and rapid (~5 min) in-tube sample preparation was performed by adding extraction solvent to a powdered sample aliquot followed by agitation, centrifugation, and filtration to recover an extract for analysis. Automated flow injection introduced 1 L of the extracts directly into the mass spectrometer ion source without chromatographic separation. Sample-to-sample analysis time was 60 s representing significant improvement over conventional liquid chromatography approaches which typically require 25-45 min, and often require more significant sample preparation procedures. Quantitative capabilities of the flow-injection analysis were tested using the method of standard additions and NIST standard reference material (SRM 3280) multivitamin/multielement tablets. The quantity determined for each B-vitamin in SRM 3280 was within the statistical range provided for the respective certified values. The same sample preparation and analysis approach was also applied to two different commercial vitamin supplement tablets and proved to be successful in the quantification of the selected B-vitamins as evidenced by an agreement with the labels values and the results obtained using isotope dilution liquid chromatography/mass spectrometry.

59 BASIC BIOLOGICAL SCIENCES↗

Investigating the use of in situ liquid cell scanning transmission electron microscopy

Engineering nanoparticles with desired shape-dependent properties is the key to many applications in nanotechnology. Although many synthetic procedures exist to produce anisotropic gold nanoparticles, the dynamics of growth are typically unknown or hypothetical. In the case of seed-mediated growth in the presence of DNA into anisotropic nanoparticles, it is not known exactly how DNA directs growth into specific morphologies. A series of preliminary experiments were carried out to contribute to the investigation of the possible mechanism of DNA-mediated growth of gold nanoprisms into gold nanostars using liquid cell scanning transmission electron microscopy (STEM). Imaging in the liquid phase was achieved through the use of a liquid cell platform and liquid cell holder that allow the sample to be contained within a “chip sandwich” between two electron transparent windows. Ex situ growth experiments were performed using Au-T30 NPrisms (30-base thymine oligonucleotide-coated gold nanoprisms) that are expected to grow into gold nanostars. Growth to form these nanostars were imaged using TEM (transmission electron microscopy) and liquid cell STEM (scanning transmission electron microscopy). An attempt to perform in situ growth experiments with the same Au-T30 nanoprisms revealed challenges in obtaining desired morphology results due to the environmental differences within the liquid cell compared to the ex situ environment. Different parameters in the experimental method were explored including fluid line set up, simultaneous and alternating reagent addition, and the effect of different liquid cell volumes to ensure adequate flow of reagents into the liquid cell. Lastly, the binding affinities were compared for T30 and A30 DNA incubated with gold nanoparticles using zeta potential measurements, absorption spectroscopy, and isothermal titration calorimetry (ITC). It was previously reported thymine bases have a lower binding affinity to gold surfaces than adenine bases. However, the results reported here contradict the previously reported data. Future prospectives on this work are outlined.

36 MATERIALS SCIENCE↗

Systematic Study of the Cathode Compositional Dependency of Cross-Talk Behavior in Li-Ion Battery

While LiNi x Mn y Co 1-x-y O 2 (NMC) is one of the most widely used cathode materials for lithium-ion batteries (LIBs), the composition of NMC is evolving to Ni-rich NMC to achieve higher lithium capacity that fulfills the constant demand for LIBs with ever-higher energy densities. The change in the composition of NMC affects electrochemical features and electrode cross-talk, which explains the performance change during cycling. Here in this study, we introduce various NMC materials (LiNi 0.5 Mn 0.3 Co 0.2 O 2 , LiNi 0.6 Mn 0.2 Co 0.2 O 2 and LiNi 0.8 Mn 0.1 Co 0.1 O 2 ) to reveal how the NMC composition affects electrode cross-talk. The study reveals that NMC composition strongly affects transition metal dissolution; dissolution of manganese linearly decreases as its stoichiometric ratio in NMC decreases, while dissolution of nickel is only prominent in LiNi 0.8 Mn 0.1 Co 0.1 O 2 . Aged electrolyte samples are characterized with high-performance liquid chromatography, and two electrolyte decomposition species, C 8 H 16 O 5 and C 9 H 18 O 5 , are identified across all samples.

25 ENERGY STORAGE↗

Detection of THz radiation with devices made from wafers with HgTe and InSb quantum wells

In this study we present measurements of the Terahertz (THz) photoconductivity of 2D electron system realized at HgTe/HgCdTe and AlInSb/InSb/AlInSb quantum wells (QWs) in Corbino geometry (inner and outer radius: 500 {mu}m and 1500 {mu}m) with different mobilities and electron densities. To characterize the devices, the Shubnikov-de Haas (SdH) effect up to magnetic fields B of 7T and current-voltage (I-V) characteristics at various magnetic fields were measured. The THz radiation is provided by a p-Ge laser which operates with a magnetic field and a high voltage for the electrical pumping. The stimulated emission is caused by transitions between Landau levels of light holes [1]. The laser is tunable in the range between 1.7 to 2.5 THz (corresponding to wavelengths between 120 to 180 {mu}m or energies of 7 to 12 meV). The laser is pulsed with a pulse rate of 1 Hz and pulse lengths of about 1 {mu}s with low switching times (about 20 ns). The monochromatic THz radiation is transferred to our samples via a 0.32m long brass waveguide immersed in liquid Helium. The detection of a change in the conductivity of the sample due to absorption of THz-radiation (photoresponse) requires a low-noise circuit. For the Corbino-shaped samples the photoresponse (PR) is measured via a resistor R{sub V} of 1 k{Omega}. The signal is transferred via in a high-frequency cable and detected with a digital oscilloscope.

36 MATERIALS SCIENCE↗