Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC BEARINGS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

High precision moving magnet chopper for variable operation conditions

In the context of an ESTEC technology contract, a Chopping Mechanism was developed and built with the Far Infrared and Submillimeter Telescope (FIRST) astronomy mission as a reference. The task of the mechanism is to tilt the subreflector of the telescope with an assumed mass of 2.5 kg about one chopping axis at nominal frequencies of up to 5 Hz and chopping angles of up to +/- 11.25 mrad with high efficiency (minimum time for position change). The chopping axis is required to run through the subreflector vertex. After performing a concept trade-off also considering the low operational temperatures in the 130 K range, a design using moving magnet actuators was found to be the favorite one. In addition, a bearing concept using flexible pivots was chosen to meet the high chopping accuracy required. With this approach, a very reliable design could be realized, since the actuators work without any mechanical contact between its moving and fixed parts, and the only bearings used are two flexible pivots supporting the subreflector mounting interface. The mechanism was completely built in titanium in a lightweight and stiff design. The moving magnet actuators were designed to meet the stringent requirements for minimum risetime (time necessary to move from one angular position to a new one) in the 20 msec range. The angular position and the corresponding chopping frequency as well can be arbitrarily selected by the user.

Aicher, Winfried↗

Measurement and analysis of magnetic field variation during a class 2b flare

A digital analysis of high-time-resolution videomagnetograms taken during a class 2b flare that occurred at 60 deg east is reported. The data were obtained at the Big Bear Observatory and calibrated by a Mt. Wilson magnetogram. Changes of weak magnetic fields (less than 100 G) with an amplitude of 30% to 100% have been detected over 55% of the optical flare region, apparently taking place at the initial phase of the flare. Statistical considerations suggest a real flare association with most of these changes. H-alpha observations show that large changes took place over the footpoints of heavily inclined structures like penumbral fibrils, while smaller changes took place over the plage region. An apparent polarity reversal was found at the feet of erupted fibrils. Based on force-free field calculations these changes can be reasonably explained as a transformation of the current-carrying fields to potential fields which produced large changes in the field-line inclination and rotation.

Tanaka, K.↗

Pigmenting agents in Martian soils: inferences from spectral, Mossbauer, and magnetic properties of nanophase and other iron oxides in Hawaiian palagonitic soil PN-9

We have examined a Hawaiian palagonitic tephra sample (PN-9) that has spectroscopic similarities to Martian bright regions using a number of analytical techniques, including Mossbauer and reflectance spectroscopy, X-ray diffraction, instrumental neutron activation analysis, electron probe microanalysis, transmission electron microscopy, and dithionite-citrate-bicarbonate extraction. Chemically, PN-9 has a Hawaiitic composition with alkali (and presumably silica) loss resulting from leaching by meteoric water during palagonitization; no Ce anomaly is present in the REE pattern. Mineralogically, our results show that nanophase ferric oxide (np-Ox) particles (either nanophase hematite (np-Hm) or a mixture of ferrihydrite and np-Hm) are responsible for the distinctive ferric doublet and visible-wavelength ferric absorption edge observed in Mossbauer and reflectivity spectra, respectively, for this and other spectrally similar palagonitic samples. The np-Ox particles appear to be imbedded in a hydrated aluminosilicate matrix material; no evidence was found for phyllosilicates. Other iron-bearing phases observed are titanomagnetite, which accounts for the magnetic nature of the sample; olivine; pyroxene; and glass. By analogy, np-Ox is likely the primary pigmenting agent of the bright soils and dust of Mars.

Minerals/analysis↗

Observations of vector magnetic fields with a magneto-optic filter

The use of the magnetooptic filter to observe solar magnetic fields in the potassium line at 7699 A is described. The filter has been used in the Big Bear videomagnetograph since October 23. It gives a high sensitivity and dynamic range for longitudnal magnetic fields and enables measurement of transverse magnetic fields using the sigma component. Examples of the observations are presented.

Cacciani, Alessandro↗

Nuclear resonant inelastic X-ray scattering at high pressure and low temperature

In this study, a new synchrotron radiation experimental capability of coupling nuclear resonant inelastic X-ray scattering with the cryogenically cooled high-pressure diamond anvil cell technique is presented. The new technique permits measurements of phonon density of states at low temperature and high pressure simultaneously, and can be applied to studies of phonon contribution to pressure- and temperature-induced magnetic, superconducting and metal–insulator transitions in resonant isotope-bearing materials. In this report, a pnictide sample, EuFe 2 As 2 , is used as an example to demonstrate this new capability at beamline 3-ID of the Advanced Photon Source, Argonne National Laboratory. A detailed description of the technical development is given. The Fe-specific phonon density of states and magnetism from the Fe sublattice in Eu 57 Fe 2 As 2 at high pressure and low temperature were derived by using this new capability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Complex magnetic behavior of the sawtooth Fe chains in Rb2Fe2O(AsO4)2

Results of magnetic eld and temperature dependent neutron diraction and magnetization mea- surements on oxy-arsenate Rb2Fe2O(AsO4)2 are reported. The crystal structure of this compound contains pseudo-one-dimensional [Fe2O6] sawtooth-like chains, formed by corner sharing isosce- les triangles of Fe3+ ions occupying two nonequivalent crystallographic sites. The chains extend innitely along the crystallographic b-axis and are structurally conned from one another via dia- magnetic (AsO4)3- units along the a-axis, and Rb+ cations along the c-axis direction. Neutron diraction measurements indicate the onset of a long range antiferromagnetic order below approxi- mately 25 K. The magnetic structure consists of ferrimagnetic chains which are antiferromagnetically coupled with each other. Within each chain, one of the two Fe sites carries a moment which lies along the b-axis, while the second site bears a canted moment in the opposite direction. Exter- nally applied magnetic eld induces a transition to a ferrimagnetic state, in which the coupling between the sawtooth chains becomes ferromagnetic. Magnetization measurements performed on optically-aligned single crystals reveal evidence for an uncompensated magnetization at low mag- netic elds that could emerge from to a phase-segregated state with ferrimagnetic inclusions or from antiferromagnetic domain walls. The observed magnetic states and the competition between them is expected to arise from strongly frustrated interactions within the sawtooth chains and relatively weak coupling between them.

Garlea, Vasile O↗

International Symposium on Magnetic Suspension Technology, Part 1

The goal of the symposium was to examine the state of technology of all areas of magnetic suspension and to review related recent developments in sensors and controls approaches, superconducting magnet technology, and design/implementation practices. The symposium included 17 technical sessions in which 55 papers were presented. The technical session covered the areas of bearings, sensors and controls, microgravity and vibration isolation, superconductivity, manufacturing applications, wind tunnel magnetic suspension systems, magnetically levitated trains (MAGLEV), space applications, and large gap magnetic suspension systems.

Nelson J Groom↗

Pressure induced magneto-structural phase transitions in layered RMn{sub 2}X{sub 2} compounds (invited)

We have studied a range of pseudo-ternaries derived from the parent compound PrMn{sub 2}Ge{sub 2}, substituting for each constituent element with a smaller one to contract the lattice. This enables us to observe the magneto-elastic transitions that occur as the Mn-Mn nearest neighbour distance is reduced and to assess the role of Pr on the magnetism. Here, we report on the PrMn{sub 2}Ge{sub 2−x}Si{sub x}, Pr{sub 1−x}Y{sub x}Mn{sub 2}Ge{sub 2}, and PrMn{sub 2−x}Fe{sub x}Ge{sub 2} systems. The pressure produced by chemical substitution in these pseudo-ternaries is inherently non-uniform, with local pressure variations dependent on the local atomic distribution. We find that concentrated chemical substitution on the R or X site (e.g., in Pr{sub 0.5}Y{sub 0.5}Mn{sub 2}Ge{sub 2} and PrMn{sub 2}Ge{sub 0.8}Si{sub 1.2}) can produce a separation into two distinct magnetic phases, canted ferromagnetic and canted antiferromagnetic, with a commensurate phase gap in the crystalline lattice. This phase gap is a consequence of the combination of phase separation and spontaneous magnetostriction, which is positive on transition to the canted ferromagnetic phase and negative on transition to the canted antiferromagnetic phase. Our results show that co-existence of canted ferromagnetic and antiferromagnetic phases depends on chemical pressure from the rare earth and metalloid sites, on local lattice strain distributions and on applied magnetic field. We demonstrate that the effects of chemical pressure bear close resemblance to those of mechanical pressure on the parent compound.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of flux penetration on the load capacity of passive superconducting bearings

A dramatic improvement has been made in the load capacity of a superconductor magnet pair. The measured load capacities that stood at 0.1 psi two years back were improved now to an impressive 40 psi. This improvement is mainly due to better processing techniques developed by the superconducting material processing community. The analysis indicates that, by using these processing techniques that efficiently prevent flux penetration, high load capacities were achieved. With these developments, it is possible to insert passive bearings into actual applications within the next few years.

Rao, Dantam K.↗

Experimental Evaluation of the Deceleration of Aluminum Cylinders Rotating in a Magnetic Field and Comments on Magnetic Damping of a Flywheel Control

An experimental investigation has been made to determine the magnetic deceleration of a closed-end cylinder rotating in a magnetic field by use of opposed ball and socket air bearing support. The theories of smythe and Hooper were compared with the experimental data for aluminum cylinders with fineness ratios of 9:1, 4:1, and 2:l and a wall thickness of 0.254 centimeter and one cylinder with a fineness ratio of 6:1 and a wall thickness of 0.508 centimeter. A method is outlined by which the magnetic damping coefficient for the spinning motion of a body of revolution may be determined experimentally. The theory of Smythe for a thin-walled cylinder predicts values greater than experimental results for fineness ratios of less than 6:l. Hooper's theory is in agreement with the experimental results through-out the range of fineness ratios tested. A utilization of the magnetic damping to prevent overspeeding of a flywheel used in a satellite orientation system is discussed.

Eide, Donald G.↗

Acoustic and electrical properties of Fe-Ti oxides with application to the deep lunar mantle

The overturn of titanium-rich mantle cumulates has been invoked to explain the structure and dynamics of the Moon. These dense cumulates are stable at the core-mantle boundary (CMB) and could explain field observations inferred from geophysical studies. Here, we report acoustic and electrical experiments on natural ilmenite-rutile aggregates up to 4.5 GPa and 1920 K. Seismic velocities show a weak pressure and temperature dependence, with Vs ~ 4.2 (+/-0.2) km/s and Vp ~8.0 (+/-0.2) km/s at the CMB conditions. Conductivity increases by a factor of 10 4 from 373 to 1920 K and is >10(3) S/m above 1573 K. Seismic and electrical models for the lunar mantle based on our results, considering mixtures of Fe-Ti oxides and olivine, indicate that field velocity and conductivity estimates are reproduced satisfactorily with 3-16 vol.% Fe-Ti oxides and 20 vol.% melt. Interactions between a Ti-rich, melt-bearing layer and the adjacent core likely affect the cooling and magnetic history of the Moon.

58 GEOSCIENCES↗

IS FLUX ROPE A NECESSARY CONDITION FOR THE PROGENITOR OF CORONAL MASS EJECTIONS?

A magnetic flux rope structure is believed to exist in most coronal mass ejections (CMEs). However, it has been long debated whether the flux rope exists before eruption or if it is formed during eruption via magnetic reconnection. The controversy has continued because of our lack of routine measurements of the magnetic field in the pre-eruption structure, such as solar filaments. However, recently an indirect method was proposed to infer the magnetic field configuration based on the sign of helicity and the bearing direction of the filament barbs. In this paper, we apply this method to two erupting filament events, one on 2014 September 2 and the other on 2011 March 7, and find that the first filament is supported by a magnetic flux rope and the second filament is supported by a sheared arcade, i.e., the first one is an inverse-polarity filament and the second one is a normal-polarity filament. With the identification of the magnetic configurations in these two filaments, we stress that a flux rope is not a necessary condition for the pre-CME structure.

79 ASTRONOMY AND ASTROPHYSICS↗

A linear magnetic motor and generator

In linear magnetic motor and generator suitable for remote and hostile environments, magnetic forces drive reciprocating shaft along its axis. Actuator shaft is located in center of cylindrical body and may be supported by either contacting or noncontacting bearings. When device operates as bidirectional motor, drive coil selectively adds and subtracts magnetic flux to and from flux paths, producing forces that drive actuator along axis. When actuator is driven by external reciprocating engine, device becomes ac generator.

Studer, P. A.↗

Lightweight Magnetic Cooler With a Reversible Circulator

A design of a highly efficient and lightweight space magnetic cooler has been developed that can continuously provide remote/distributed cooling at temperatures in the range of 2 K with a heat sink at about 15 K. The innovative design uses a cryogenic circulator that enables the cooler to operate at a high cycle frequency to achieve a large cooling capacity. The ability to provide remote/distributed cooling not only allows flexible integration with a payload and spacecraft, but also reduces the mass of the magnetic shields needed. The active magnetic regenerative refrigerator (AMRR) system is shown in the figure. This design mainly consists of two identical magnetic regenerators surrounded by their superconducting magnets and a reversible circulator. Each regenerator also has a heat exchanger at its warm end to reject the magnetization heat to the heat sink, and the two regenerators share a cold-end heat exchanger to absorb heat from a cooling target. The circulator controls the flow direction, which cycles in concert with the magnetic fields, to facilitate heat transfer. Helium enters the hot end of the demagnetized column, is cooled by the refrigerant, and passes into the cold-end heat exchanger to absorb heat. The helium then enters the cold end of the magnetized column, absorbing heat from the refrigerant, and enters the hot-end heat exchanger to reject the magnetization heat. The efficient heat transfer in the AMRR allows the system to operate at a relatively short cycle period to achieve a large cooling power. The key mechanical components in the magnetic cooler are the reversible circulator and the magnetic regenerators. The circulator uses non-contacting, self-acting gas bearings and clearance seals to achieve long life and vibration- free operation. There are no valves or mechanical wear in this circulator, so the reliability is predicted to be very high. The magnetic regenerator employs a structured bed configuration. The core consists of a stack of thin GGG disks alternating with thin polymer insulating films. The structured bed reduces flow resistance in the regenerator and therefore the pumping work by the cryogenic circulator. This magnetic cooler will enable cryogenic detectors for sensing infrared, x-ray, gamma-ray, and submillimeter radiation in future science satellites, as well as the detector systems in the Constellation-X (Con-X) and the Single Aperture Far-Infrared observatory (SAFIR). Scientific ap p - lica tions for this innovation include cooling for x-ray micro calorimeter spectrometers used for microanalysis, cryogenic particle detectors, and superconducting tunnel junction de tectors for biomolecule mass spectrometry. The cooler can be scaled to provide very large cooling capacities at very low temperatures, ideal for liquid helium and liquid hydrogen productions.

Chen, Weibo↗

Sound velocities of compressed Fe{sup 3}c from simultaneous synchrotron x-ray diffraction and nuclear resonant scattering measurements.

The applications of nuclear resonant scattering in laser-heated diamond anvil cells have provided an important probe for the magnetic and vibrational properties of {sup 57}Fe-bearing materials under high pressure and high temperature. Synchrotron X-ray diffraction is one of the most powerful tools for studying phase stability and equation of state over a wide range of pressure and temperature conditions. Recently an experimental capability has been developed for simultaneous nuclear resonant scattering and X-ray diffraction measurements using synchrotron radiation. Here the application of this method to determine the sound velocities of compressed Fe{sub 3}C is shown. The X-ray diffraction measurements allow detection of microscale impurities, phase transitions and chemical reactions upon compression or heating. They also provide information on sample pressure, grain size distribution and unit cell volume. By combining the Debye velocity extracted from the nuclear resonant inelastic X-ray scattering measurements and the structure, density and elasticity data from the X-ray diffraction measurements simultaneously obtained, more accurate sound velocity data can be derived. Our results on few-crystal and powder samples indicate strong anisotropy in the sound velocities of Fe{sub 3}C under ambient conditions.

43 PARTICLE ACCELERATORS↗

Crustal Magnetic Fields

Cosmos 49, Polar Orbit Geophysical Observatory (POGO) (Orbiting Geophysical Observatory (OGO-2, 4 and 6)) and Magsat have been the only low-earth orbiting satellites to measure the crustal magnetic field on a global scale. These missions revealed the presence of long- wavelength (> 500 km) crustal anomalies predominantly located over continents. Ground based methods were, for the most part, unable to record these very large-scale features; no doubt due to the problems of assembling continental scale maps from numerous smaller surveys acquired over many years. Questions arose as to the source and nature of these long-wave length anomalies. As a result there was a great stimulant given to the study of the magnetic properties of the lower crust and upper mantle. Some indication as to the nature of these deep sources has been provided by the recent results from the deep crustal drilling programs. In addition, the mechanism of magnetization, induced or remanent, was largely unknown. For computational ease these anomalies were considered to result solely from induced magnetization. However, recent results from Mars Orbiter Laser Altimeter (MOLA), a magnetometer-bearing mission to Mars, have revealed crustal anomalies with dimensions similar to the largest anomalies on Earth. These Martian features could only have been produced by remanent magnetization, since Mars lacks an inducing field. The origin of long-wavelength crustal anomalies, however, has not been completely determined. Several large crustal magnetic anomalies (e.g., Bangui, Kursk, Kiruna and Central Europe) will be discussed and the role of future satellite magnetometer missions (Orsted, SUNSAT and Champ) in their interpretation evaluated.

Taylor, Patrick T.↗

Multistage Magnetic Separator of Cells and Proteins

The multistage electromagnetic separator for purifying cells and magnetic particles (MAGSEP) is a laboratory apparatus for separating and/or purifying particles (especially biological cells) on the basis of their magnetic susceptibility and magnetophoretic mobility. Whereas a typical prior apparatus based on similar principles offers only a single stage of separation, the MAGSEP, as its full name indicates, offers multiple stages of separation; this makes it possible to refine a sample population of particles to a higher level of purity or to categorize multiple portions of the sample on the basis of magnetic susceptibility and/or magnetophoretic mobility. The MAGSEP includes a processing unit and an electronic unit coupled to a personal computer. The processing unit includes upper and lower plates, a plate-rotation system, an electromagnet, an electromagnet-translation system, and a capture-magnet assembly. The plates are bolted together through a roller bearing that allows the plates to rotate with respect to each other. An interface between the plates acts as a seal for separating fluids. A lower cuvette can be aligned with as many as 15 upper cuvette stations for fraction collection during processing. A two-phase stepping motor drives the rotation system, causing the upper plate to rotate for the collection of each fraction of the sample material. The electromagnet generates a magnetic field across the lower cuvette, while the translation system translates the electromagnet upward along the lower cuvette. The current supplied to the electromagnet, and thus the magnetic flux density at the pole face of the electromagnet, can be set at a programmed value between 0 and 1,400 gauss (0.14 T). The rate of translation can be programmed between 5 and 2,000 m/s so as to align all sample particles in the same position in the cuvette. The capture magnet can be a permanent magnet. It is mounted on an arm connected to a stepping motor. The stepping motor rotates the arm to position the capture magnet above the upper cuvette into which a fraction of the sample is collected. The electronic unit includes a power switch, power-supply circuitry that accepts 110-Vac input power, an RS-232 interface, and status lights. The personal computer runs the MAGSEP software and controls the operation of the MAGSEP through the RS-232 interface. The status of the power, the translating electromagnet, the capture magnet, and the rotation of the upper plate are indicated in a graphical user interface on the computer screen.

Barton, Ken↗

A lunar metal core

Recent work generally supports the hypothesis of a centrally condensed lunar core. Data regarding the axial moment on the basis of laser tracking and satellite orbit analyses place an upper limit of about 500 km on an Fe core, or 700 km upon an Fe/FeS core, if differentiation in the lithosphere is ignored. Whether a metallized core exists in the moon has a profound bearing upon the question of the origin of the magnetic fields responsible for the present day magnetization on the lunar surface. Recent efforts to examine in detail signals arising from lunar induction at very low frequency are discussed. The discussion represents an extension of a study reported by Wiskerchen et al. (1976). The present data base consists of all Apollo 12 data which fulfill the requirement that the surface magnetometer be on the sunward side of the moon and at least 10 deg from the lunar optical terminator. It is found that only marginal evidence exists for a metallized core at a radius of 400 km in the moon.

Wiskerchen, M. J.↗