Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Magnetic Resonance, Vendor-independent, Intensity Histogram Analysis Predicting Pathologic Complete Response After Radiochemotherapy of Rectal Cancer

The objective of this study is finding an intensity based histogram (IBH) signature to predict pathologic complete response (pCR) probability using only pre-treatment magnetic resonance (MR) and validate it externally in order to create a workflow for the external validation of an MR IBH signature and to apply the model out of the environment where it has been tuned. The impact of pCR and the final predictors on the survival outcome were also evaluated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Combined X-Ray Radiography and Magnetic Resonance (XMR) Imaging-Versus Computed Tomography-Based Dosimetry for the Evaluation of Permanent Prostate Brachytherapy Implants

Purpose: To present a method for the dosimetric analysis of permanent prostate brachytherapy implants using a combination of stereoscopic X-ray radiography and magnetic resonance (MR) imaging (XMR) in an XMR facility, and to compare the clinical results between XMR- and computed tomography (CT)-based dosimetry. Methods and Materials: Patients who had received nonstranded iodine-125 permanent prostate brachytherapy implants underwent XMR and CT imaging 4 weeks later. Four observers outlined the prostate gland on both sets of images. Dose-volume histograms (DVHs) were derived, and agreement was compared among the observers and between the modalities. Results: A total of 30 patients were evaluated. Inherent XMR registration based on prior calibration and optical tracking required a further automatic seed registration step that revealed a median root mean square registration error of 4.2 mm (range, 1.6-11.4). The observers agreed significantly more closely on prostate base and apex positions as well as outlining contours on the MR images than on those from CT. Coefficients of variation were significantly higher for observed prostate volumes, D90, and V100 parameters on CT-based dosimetry as opposed to XMR. The XMR-based dosimetry showed little agreement with that from CT for all observers, with D90 95% limits of agreement ranges of 65, 118, 79, and 73 Gy for Observers 1, 2, 3, and 4, respectively. Conclusions: The study results showed that XMR-based dosimetry offers an alternative to other imaging modalities and registration methods with the advantages of MR-based prostate delineation and confident three-dimensional reconstruction of the implant. The XMR-derived dose-volume histograms differ from the CT-derived values and demonstrate less interobserver variability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Potential Impact of Preoperative Magnetic Resonance Imaging of the Breast on Patient Selection for Accelerated Partial Breast Irradiation

Purpose: Accelerated partial breast irradiation (APBI) after breast-conserving therapy is currently under investigation in prospective randomized studies. Multifocality and multicentricity are exclusion criteria for APBI. Preoperative breast magnetic resonance imaging (MRI) can detect ipsilateral and contralateral invasive tumor foci or ductal carcinoma in situ in addition to conventional diagnostic methods (clinical examination, mammography, and ultrasonography). The objective of this retrospective study was to evaluate the impact of preoperative MRI on patient selection for APBI. Methods and Materials: From 2002 to 2007, a total of 579 consecutive, nonselected patients with newly diagnosed early-stage breast cancer received preoperative breast MRI in addition to conventional imaging studies at the Bonn University Breast Cancer Center. In retrospect, 113 patients would have met the criteria for APBI using conventional imaging workup (clinical tumor size {<=}3 cm; negative axillary lymph node status; unifocal disease; no evidence of distant metastases; no invasive lobular carcinoma, ductal and lobular carcinoma in situ, or Paget's disease). We analyzed the amount of additional ipsilateral and contralateral tumor foci detected by MRI. Results: MRI detected additional tumor foci in 8.8% of patients eligible for APBI (11 tumor foci in 10 of 113 patients), either ipsilateral (n = 7, 6.2%) or contralateral (n = 4, 3.5%). In 1 patient, MRI helped detect additional tumor focus both ipsilaterally and contralaterally. Conclusions: Preoperative breast MRI is able to identify additional tumor foci in a clinically relevant number of cases in this highly selected group of patients with low-risk disease and may be useful in selecting patients for APBI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

T2-weighted four dimensional magnetic resonance imaging with result-driven phase sorting

Purpose: T2-weighted MRI provides excellent tumor-to-tissue contrast for target volume delineation in radiation therapy treatment planning. This study aims at developing a novel T2-weighted retrospective four dimensional magnetic resonance imaging (4D-MRI) phase sorting technique for imaging organ/tumor respiratory motion. Methods: A 2D fast T2-weighted half-Fourier acquisition single-shot turbo spin-echo MR sequence was used for image acquisition of 4D-MRI, with a frame rate of 2–3 frames/s. Respiratory motion was measured using an external breathing monitoring device. A phase sorting method was developed to sort the images by their corresponding respiratory phases. Besides, a result-driven strategy was applied to effectively utilize redundant images in the case when multiple images were allocated to a bin. This strategy, selecting the image with minimal amplitude error, will generate the most representative 4D-MRI. Since we are using a different image acquisition mode for 4D imaging (the sequential image acquisition scheme) with the conventionally used cine or helical image acquisition scheme, the 4D dataset sufficient condition was not obviously and directly predictable. An important challenge of the proposed technique was to determine the number of repeated scans (N{sub R}) required to obtain sufficient phase information at each slice position. To tackle this challenge, the authors first conducted computer simulations using real-time position management respiratory signals of the 29 cancer patients under an IRB-approved retrospective study to derive the relationships between N{sub R} and the following factors: number of slices (N{sub S}), number of 4D-MRI respiratory bins (N{sub B}), and starting phase at image acquisition (P{sub 0}). To validate the authors’ technique, 4D-MRI acquisition and reconstruction were simulated on a 4D digital extended cardiac-torso (XCAT) human phantom using simulation derived parameters. Twelve healthy volunteers were involved in an IRB-approved study to investigate the feasibility of this technique. Results: 4D data acquisition completeness (C{sub p}) increases as NR increases in an inverse-exponential fashion (C{sub p} = 100 − 99 × exp(−0.18 × N{sub R}), when N{sub B} = 6, fitted using 29 patients’ data). The N{sub R} required for 4D-MRI reconstruction (defined as achieving 95% completeness, C{sub p} = 95%, N{sub R} = N{sub R,95}) is proportional to N{sub B} (N{sub R,95} ∼ 2.86 × N{sub B}, r = 1.0), but independent of N{sub S} and P{sub 0}. Simulated XCAT 4D-MRI showed a clear pattern of respiratory motion. Tumor motion trajectories measured on 4D-MRI were comparable to the average input signal, with a mean relative amplitude error of 2.7% ± 2.9%. Reconstructed 4D-MRI for healthy volunteers illustrated clear respiratory motion on three orthogonal planes, with minimal image artifacts. The artifacts were presumably caused by breathing irregularity and incompleteness of data acquisition (95% acquired only). The mean relative amplitude error between critical structure trajectory and average breathing curve for 12 healthy volunteers is 2.5 ± 0.3 mm in superior–inferior direction. Conclusions: A novel T2-weighted retrospective phase sorting 4D-MRI technique has been developed and successfully applied on digital phantom and healthy volunteers.

60 APPLIED LIFE SCIENCES↗

High fidelity simulations of contaminant dispersion in an urban environment with comparison to magnetic resonance imaging measurements

The dispersion of a contaminant in an urban environment has the potential to impact a large population of people. In this work, a complex urban canopy flow based on the Oklahoma City downtown business district circa 2003 is studied using Magnetic Resonance Imaging (MRI) and high-fidelity Large Eddy Simulations (LES). MRI is a novel experimental technique that can provide high-resolution measurements in four dimensions (three spatial and temporal) for lab scale models. The experiments and simulations use the same geometry and boundary conditions providing a one-to-one comparison of the two methods. Results are presented on the time-averaged velocity and concentration fields, the temporal dynamics of the concentration plumes for a transient release, and a novel Cloud Identification Algorithm that can separate plumes produced by periodic contaminant releases used for ensemble averaging over many releases. The MRI and LES datasets both include millions of measurement voxels and the comparisons highlight the complex 3D nature of the flow including strong vertical velocities in spanwise street canyons and flow acceleration in streamwise street canyons. The concentration fields are qualitatively similar albeit the LES shows larger dispersion. A quantitative analysis with performance measures compares the datasets pointwise and demonstrates that the two 3D datasets are similar with respect to many measures including a fractional bias of 0.02 (ideal=0.0), correlation coefficient of 0.87 (ideal = 1.0), and the fraction points within a factor of 2 is 0.98 (ideal = 1.0). Plume analysis compares the arrival and residence time of contaminant and is found to vary significantly with location within the urban environment with arrival times between 0 and 1.25 and differences within the contaminant cloud less than 10% at most locations.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of left ventricular mass on cadmium-zinc-telluride imaging: Validation against cardiac magnetic resonance

Background: Single-photon emission computed tomography has shown relevant limitations in the quantification of left ventricular (LV) mass. We sought to compare the estimates of LV mass on Cadmium-Zinc-Telluride (CZT) myocardial perfusion imaging (MPI) as compared to cardiac magnetic resonance (CMR). Methods and results: Twenty-five patients underwent MPI on a CZT camera and CMR on a 1.5 T scanner within 12 ± 3 weeks. LV mass was quantified on CZT images using two softwares: 4D-MSPECT (4DM) and Emory Cardiac Toolbox (ECTb). LV mass by CMR was quantified using MASS software (Medis, Leiden, The Netherlands). LV mass values obtained with 4DM and ECTb were highly reproducible [intraclass correlation coefficients .98 (95% CI .97-.99), and .98 (95% CI 0.97-.99), respectively]. The mean LVM mass values were 151 ± 44 g on CMR, 151 ± 43 g with 4DM (P = NS vs CMR), and 157 ± 42 g with ECTb (P < .001 vs CMR; P = .007 vs 4DM) CZT images. There was an excellent correlation between LV mass values between CMR and both 4DM (R{sup 2} = .95; P < .001) and ECTb (R{sup 2} = .98; P < .001) with narrow limits of agreement (− 13.6% to + 13.4% for 4DM, and − 5.6% to + 14.1% for ECTb). Conclusions: The evaluation of LV mass is feasible on CZT images, showing excellent agreement with CMR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of [{sup 11}C]choline Positron Emission Tomography With T2- and Diffusion-Weighted Magnetic Resonance Imaging for Delineating Malignant Intraprostatic Lesions

Purpose: The purpose of this study was to compare the accuracy of [{sup 11}C]choline positron emission tomography (CHOL-PET) with that of the combination of T2-weighted and diffusion-weighted (T2W/DW) magnetic resonance imaging (MRI) for delineating malignant intraprostatic lesions (IPLs) for guiding focal therapies and to investigate factors predicting the accuracy of CHOL-PET. Methods and Materials: This study included 21 patients who underwent CHOL-PET and T2W/DW MRI prior to radical prostatectomy. Two observers manually delineated IPL contours for each scan, and automatic IPL contours were generated on CHOL-PET based on varying proportions of the maximum standardized uptake value (SUV). IPLs identified on prostatectomy specimens defined reference standard contours. The imaging-based contours were compared with the reference standard contours using Dice similarity coefficient (DSC), and sensitivity and specificity values. Factors that could potentially predict the DSC of the best contouring method were analyzed using linear models. Results: The best automatic contouring method, 60% of the maximum SUV (SUV{sub 60}) , had similar correlations (DSC: 0.59) with the manual PET contours (DSC: 0.52, P=.127) and significantly better correlations than the manual MRI contours (DSC: 0.37, P<.001). The sensitivity and specificity values were 72% and 71% for SUV{sub 60}; 53% and 86% for PET manual contouring; and 28% and 92% for MRI manual contouring. The tumor volume and transition zone pattern could independently predict the accuracy of CHOL-PET. Conclusions: CHOL-PET is superior to the combination of T2W/DW MRI for delineating IPLs. The accuracy of CHOL-PET is insufficient for gland-sparing focal therapies but may be accurate enough for focal boost therapies. The transition zone pattern is a new classification that may predict how well CHOL-PET delineates IPLs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dynamics of fluorinated imide-based ionic liquids using nuclear magnetic resonance techniques

There is increasing interest in studying molecular motions in ionic liquids to gain better insights into their transport properties and to expand their applications. Here, in this study, we have employed the fast field cycling relaxometry and pulsed field gradient nuclear magnetic resonance techniques to investigate the rotational and translational dynamics of fluorinated imide-based ionic liquids (ILs) at different temperatures. We have studied a total of six ILs composed of the 1-butyl-3-methylimidazolium cation ([BMIM] + ) combined with chemically modified analogs of the bis((trifluoromethyl)sulfonyl)imide anion ([NTf 2 ] − or [TFSI] − ). The primary objective of this paper is to broaden the understanding of how the anion's conformational flexibility, fluorination, and mass affect the molecular dynamics of cations and anions. Our results indicate that flexibility has the most significant impact on the rotational and translational motions of ions. Meanwhile, the effect of fluorination and mass is only relevant when conformational flexibility does not change significantly between the ILs being compared.

25 ENERGY STORAGE↗

Background-free dual-mode optical and 13 C magnetic resonance imaging in diamond particles

Multimodal imaging—the ability to acquire images of an object through more than one imaging mode simultaneously—has opened additional perspectives in areas ranging from astronomy to medicine. In this paper, we report progress toward combining optical and magnetic resonance (MR) imaging in such a “dual” imaging mode. They are attractive in combination because they offer complementary advantages of resolution and speed, especially in the context of imaging in scattering environments. Our approach relies on a specific material platform, microdiamond particles hosting nitrogen vacancy (NV) defect centers that fluoresce brightly under optical excitation and simultaneously “hyperpolarize” lattice C 13 nuclei, making them bright under MR imaging. We highlight advantages of dual-mode optical and MR imaging in allowing background-free particle imaging and describe regimes in which either mode can enhance the other. Leveraging the fact that the two imaging modes proceed in Fourier-reciprocal domains (real and k-space), we propose a sampling protocol that accelerates image reconstruction in sparse-imaging scenarios. Our work suggests interesting possibilities for the simultaneous optical and low-field MR imaging of targeted diamond nanoparticles.

36 MATERIALS SCIENCE↗

Plasma response to rotating resonant magnetic perturbations with a locked mode in the J-TEXT tokamak

Disruption affected by locked modes (LMs) is one of the most critical issues to be solved for tokamak fusion reactors. This paper aimed to understand the plasma response to external rotating resonant magnetic perturbations (RMPs), which are applied at a few kilohertz for controlling the pre-existing LMs. In the J-TEXT tokamak, the plasma response to a rotating RMP showed a feature of travelling wave, if no tearing mode (TM) existed. With a LM, the application of a rotating RMP led to unique features of plasma responses, which could be roughly described by the formula δb θ (θ, t)=2Asin(mθ–mθ O )cos(2πf RRMP t), where δb θ , A, m, θ O and f RRMP are the perturbed poloidal magnetic field, the amplitude, the poloidal mode number, the poloidal location of the TM's O-point and the frequency of the rotating RMP. These features are analogous to that of a standing wave in the TM rest frame, with the nodes locating at the O-/X- points. The perturbations of electron temperature, T e , due to plasma responses were zero or minimal inside the magnetic island or outside the magnetic island but at the same poloidal positions as the O-/X- points. Both δb θ and the T e perturbations increased linearly with the rotating RMP. A phenomenological model is presented that the rotating RMP drives the phase oscillation of the TM by applying a periodical electromagnetic torque. Then the phase oscillation of TM, combined with the poloidal gradient of the plasma parameters, induces the plasma response measured experimentally. The nonlinear numerical modelling confirmed the forced phase oscillation of the TM, and qualitatively verified the amplitude and phase dependences among the plasma response, the phase oscillation of the TM and the rotating RMP, which have been predicted by the model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Disruption prevention using rotating resonant magnetic perturbation on J-TEXT

Major plasma disruption is one of the most critical issues to be solved for tokamak fusion reactors. Experiments to prevent mode locking and subsequent disruptions have been carried out on the J-TEXT tokamak using rotating resonant magnetic perturbations (RMPs). The tearing modes, which are locked and lead to disruptions without the application of RMPs, can be accelerated by rotating RMPs to the RMP frequency. As a result, mode locking and subsequent disruptions are delayed or prevented. The effects of RMP amplitude and frequency on disruption prevention have been investigated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Single institutional experience with initial ultrasound followed by computed tomography or magnetic resonance imaging for acute appendicitis in adults

Purpose: The objectives of this study was to assess the performance of ultrasound (US) for suspected appendicitis in adult patients and to evaluated the additive value of short-interval (within 1 week) computed tomography (CT) or Magnetic Resonance Imaging (MRI) after performing an initial US. Methods: In this IRB-approved, HIPAA-compliant, retrospective study, electronic medical records (EMRs) were queried for “US appendicitis” performed over a 2-year interval. EMR was reviewed for CT or MRI performed within 1 week of this exam, and if any new or additional information was available at subsequent exam. White count, patient disposition, and pathology, if surgery was performed, were also recorded. Results: 682 patients underwent US for appendicitis over a 2-year duration, age range from 18 to 92 years (average: 30.1 years, M:F = 141:541). Findings showed 126/682 patients with normal appendix, 75/682 uncomplicated appendicitis, and 4/682 with complicated appendicitis. When performed, no additional findings were seen in these groups on short-interval CT or MRI. 2/682 patients had equivocal findings on US but eventually had normal appendix identified on CT. Four hundred and seventy-three patients had non-visualized appendix, of which only 14/473 (3.1%) eventually had appendicitis. Conclusions: Ultrasound is an effective initial modality for evaluating appendicitis even in adult patients. Once a normal appendix, uncomplicated or complicated appendicitis is identified on US, no further imaging is necessary. Very few patients with non-visualization of the appendix eventually have appendicitis. Hence, these patients can be managed with active clinical follow-up rather than immediate CT or MRI. Symptoms and clinical scoring systems can be used for triage of these patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tumor Volume Changes Assessed by Three-Dimensional Magnetic Resonance Volumetry in Rectal Cancer Patients After Preoperative Chemoradiation: The Impact of the Volume Reduction Ratio on the Prediction of Pathologic Complete Response

Purpose: The aim of this study was to determine the correlation between tumor volume changes assessed by three-dimensional (3D) magnetic resonance (MR) volumetry and the histopathologic tumor response in rectal cancer patients undergoing preoperative chemoradiation therapy (CRT). Methods and Materials: A total of 84 patients who underwent preoperative CRT followed by radical surgery were prospectively enrolled in the study. The post-treatment tumor volume and tumor volume reduction ratio (% decrease ratio), as shown by 3D MR volumetry, were compared with the histopathologic response, as shown by T and N downstaging and the tumor regression grade (TRG). Results: There were no significant differences in the post-treatment tumor volume and the volume reduction ratio shown by 3D MR volumetry with respect to T and N downstaging and the tumor regression grade. In a multivariate analysis, the tumor volume reduction ratio was not significantly associated with T and N downstaging. The volume reduction ratio (>75%, p = 0.01) and the pretreatment carcinoembryonic antigen level (<=3 ng/ml, p = 0.01), but not the post-treatment volume shown by 3D MR (<= 5ml), were, however, significantly associated with an increased pathologic complete response rate. Conclusion: More than 75% of the tumor volume reduction ratios were significantly associated with a high pathologic complete response rate. Therefore, limited treatment options such as local excision or simple observation might be considered after preoperative CRT in this patient population.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simulation of High-Resolution Magnetic Resonance Images on the IBM Blue Gene/L Supercomputer Using SIMRI

Medical imaging system simulators are tools that provide a means to evaluate system architecture and create artificial image sets that are appropriate for specific applications. We have modified SIMRI, a Bloch equation-based magnetic resonance image simulator, in order to successfully generate high-resolution 3D MR images of the Montreal brain phantom using Blue Gene/L systems. Results show that redistribution of the workload allows an anatomically accurate 256 3 voxel spin-echo simulation in less than 5 hours when executed on an 8192-node partition of a Blue Gene/L system.

97 MATHEMATICS AND COMPUTING↗

Assessment of Hypoxia in Human Cervical Carcinoma Xenografts by Dynamic Contrast-Enhanced Magnetic Resonance Imaging

Purpose: Patients with advanced cervical cancer and highly hypoxic primary tumors show increased frequency of locoregional treatment failure and poor disease-free and overall survival rates. The potential usefulness of gadolinium-diethylenetriaminepentaacetic acid (Gd-DTPA)-based dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) in assessing tumor hypoxia noninvasively was investigated in the present preclinical study. Methods and Materials: CK-160 and TS-415 human cervical carcinoma xenografts transplanted intramuscularly (i.m.) or subcutaneously (s.c.) in BALB/c nu/nu mice were subjected to DCE-MRI and measurement of fraction of radiobiologically hypoxic cells. Tumor images of K{sup trans} (the volume transfer constant of Gd-DTPA) and v{sub e} (the extracellular volume fraction of the imaged tissue) were produced by pharmacokinetic analysis of the DCE-MRI data. Fraction of radiobiologically hypoxic cells was measured by using the paired survival curve method. Results: Fraction of radiobiologically hypoxic cells differed significantly among the four tumor groups. The mean values {+-} SE were determined to be 44% {+-} 7% (i.m. CK-160), 77% {+-} 10% (s.c. CK-160), 23% {+-} 5% (i.m. TS-415), and 52% {+-} 6% (s.c. TS-415). The four tumor groups differed significantly also in K{sup trans}, and there was an unambiguous inverse relationship between K{sup trans} and fraction of radiobiologically hypoxic cells. On the other hand, significant differences among the groups in v{sub e} could not be detected. Conclusions: The study supports the clinical development of DCE-MRI as a method for assessing the extent of hypoxia in carcinoma of the cervix.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiattribute probabilistic prostate elastic registration (MAPPER): Application to fusion of ultrasound and magnetic resonance imaging

Purpose: Transrectal ultrasound (TRUS)-guided needle biopsy is the current gold standard for prostate cancer diagnosis. However, up to 40% of prostate cancer lesions appears isoechoic on TRUS. Hence, TRUS-guided biopsy has a high false negative rate for prostate cancer diagnosis. Magnetic resonance imaging (MRI) is better able to distinguish prostate cancer from benign tissue. However, MRI-guided biopsy requires special equipment and training and a longer procedure time. MRI-TRUS fusion, where MRI is acquired preoperatively and then aligned to TRUS, allows for advantages of both modalities to be leveraged during biopsy. MRI-TRUS-guided biopsy increases the yield of cancer positive biopsies. In this work, the authors present multiattribute probabilistic postate elastic registration (MAPPER) to align prostate MRI and TRUS imagery. Methods: MAPPER involves (1) segmenting the prostate on MRI, (2) calculating a multiattribute probabilistic map of prostate location on TRUS, and (3) maximizing overlap between the prostate segmentation on MRI and the multiattribute probabilistic map on TRUS, thereby driving registration of MRI onto TRUS. MAPPER represents a significant advancement over the current state-of-the-art as it requires no user interaction during the biopsy procedure by leveraging texture and spatial information to determine the prostate location on TRUS. Although MAPPER requires manual interaction to segment the prostate on MRI, this step is performed prior to biopsy and will not substantially increase biopsy procedure time. Results: MAPPER was evaluated on 13 patient studies from two independent datasets—Dataset 1 has 6 studies acquired with a side-firing TRUS probe and a 1.5 T pelvic phased-array coil MRI; Dataset 2 has 7 studies acquired with a volumetric end-firing TRUS probe and a 3.0 T endorectal coil MRI. MAPPER has a root-mean-square error (RMSE) for expert selected fiducials of 3.36 ± 1.10 mm for Dataset 1 and 3.14 ± 0.75 mm for Dataset 2. State-of-the-art MRI-TRUS fusion methods report RMSE of 3.06–2.07 mm. Conclusions: MAPPER aligns MRI and TRUS imagery without manual intervention ensuring efficient, reproducible registration. MAPPER has a similar RMSE to state-of-the-art methods that require manual intervention.

60 APPLIED LIFE SCIENCES↗

Constraints on bosonic dark matter from ultralow-field nuclear magnetic resonance

The nature of dark matter, the invisible substance making up over 80% of the matter in the universe, is one of the most fundamental mysteries of modern physics. Ultralight bosons such as axions, axion-like particles, or dark photons could make up most of the dark matter. Couplings between such bosons and nuclear spins may enable their direct detection via nuclear magnetic resonance (NMR) spectroscopy: As nuclear spins move through the galactic dark-matter halo, they couple to dark matter and behave as if they were in an oscillating magnetic field, generating a dark-matter–driven NMR signal. As part of the cosmic axion spin precession experiment (CASPEr), an NMR-based dark-matter search, we use ultralow-field NMR to probe the axion-fermion “wind” coupling and dark-photon couplings to nuclear spins. No dark matter signal was detected above background, establishing new experimental bounds for dark matter bosons with masses ranging from 1.8 × 10 -16 to 7.8 × 10 -14 eV.

Science & Technology - Other Topics↗

Solid State Nuclear Magnetic Resonance Investigation of Polymer Backbone Dynamics in Poly(Ethylene Oxide) Based Lithium and Sodium Polyether-ester-sulfonate Ionomers

Polymer backbone dynamics of single ion conducting poly(ethylene oxide) (PEO)-based ionomer samples with low glass transition temperatures (Tg) have been investigated using solid-state nuclear magnetic resonance (NMR). Experiments detecting 13C with 1H decoupling under magic angle spinning (MAS) conditions identified the different components of the polymer backbone (PEO spacer and isophthalate groups) and their relative mobilities for a suite of lithium- and sodium-containing ionomer samples with varying cation contents. Variable temperature (203-373 K) 1H-13C cross-polarization MAS (CP-MAS) experiments also provided qualitative assessment of the differences in the motions of the polymer backbone components as a function of cation content and identity. Each of the main backbone components exhibit distinct motions, following the trends expected for motional characteristics based on earlier Quasi Elastic Neutron Scattering and 1H spin-lattice relaxation rate measurements. Previous 1H and 7Li spin-lattice relaxation measurements focused on both the polymer backbone and cation motion on the nanosecond timescale. The studies presented here assess the slower timescale motion of the polymer backbone allowing for a more comprehensive understanding of the polymer dynamics. The temperature dependences of 13C linewidths were used to both qualitatively and quantitatively examine the effects of cation content and identity on PEO spacer mobility. Variable contact time 1H-13C CP-MAS experiments were used to further assess the motions of the polymer backbone on the microsecond timescale. The motion of the PEO spacer, reported via the rate of magnetization transfer from 1H to 13C nuclei, becomes similar for T ≳ 1.1 Tg in all ionic samples, indicating that at similar elevated reduced temperatures the motions of the polymer backbones on the microsecond timescale become insensitive to ion interactions. These results present an improved picture, beyond those of previous findings, for the dependence of backbone dynamics on cation density (and here, cation identity as well) in these amorphous PEO-based ionomer systems.

36 MATERIALS SCIENCE↗