Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement Optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Lessons Learned from Assimilating Altimeter Data into a Coupled General Circulation Model with the GMAO Augmented Ensemble Kalman Filter

Satellite altimetry measurements have provided global, evenly distributed observations of the ocean surface since 1993. However, the difficulties introduced by the presence of model biases and the requirement that data assimilation systems extrapolate the sea surface height (SSH) information to the subsurface in order to estimate the temperature, salinity and currents make it difficult to optimally exploit these measurements. This talk investigates the potential of the altimetry data assimilation once the biases are accounted for with an ad hoc bias estimation scheme. Either steady-state or state-dependent multivariate background-error covariances from an ensemble of model integrations are used to address the problem of extrapolating the information to the sub-surface. The GMAO ocean data assimilation system applied to an ensemble of coupled model instances using the GEOS-5 AGCM coupled to MOM4 is used in the investigation. To model the background error covariances, the system relies on a hybrid ensemble approach in which a small number of dynamically evolved model trajectories is augmented on the one hand with past instances of the state vector along each trajectory and, on the other, with a steady state ensemble of error estimates from a time series of short-term model forecasts. A state-dependent adaptive error-covariance localization and inflation algorithm controls how the SSH information is extrapolated to the sub-surface. A two-step predictor corrector approach is used to assimilate future information. Independent (not-assimilated) temperature and salinity observations from Argo floats are used to validate the assimilation. A two-step projection method in which the system first calculates a SSH increment and then projects this increment vertically onto the temperature, salt and current fields is found to be most effective in reconstructing the sub-surface information. The performance of the system in reconstructing the sub-surface fields is particularly impressive for temperature, but not as satisfactory for salt.

Keppenne, Christian↗

Laser anemometer optimization

The design, construction, and testing of laser anemometer configurations for hot section velocity measurements is discussed. The optimization of the laser anemometer systems include the data processing algorithms used. Some relevant hot section properties considered are high temperature with a large background radiation, difficulty of optical access, large flow velocity variations, the presence of solid surfaces that generate reflections and low seed particle density.

Edwards, R. V.↗

THE DISKMASS SURVEY. II. ERROR BUDGET

We present a performance analysis of the DiskMass Survey. The survey uses collisionless tracers in the form of disk stars to measure the surface density of spiral disks, to provide an absolute calibration of the stellar mass-to-light ratio ({Upsilon}{sub *}), and to yield robust estimates of the dark-matter halo density profile in the inner regions of galaxies. We find that a disk inclination range of 25{sup 0}-35{sup 0} is optimal for our measurements, consistent with our survey design to select nearly face-on galaxies. Uncertainties in disk scale heights are significant, but can be estimated from radial scale lengths to 25% now, and more precisely in the future. We detail the spectroscopic analysis used to derive line-of-sight velocity dispersions, precise at low surface-brightness, and accurate in the presence of composite stellar populations. Our methods take full advantage of large-grasp integral-field spectroscopy and an extensive library of observed stars. We show that the baryon-to-total mass fraction (F{sub bar}) is not a well-defined observational quantity because it is coupled to the halo mass model. This remains true even when the disk mass is known and spatially extended rotation curves are available. In contrast, the fraction of the rotation speed supplied by the disk at 2.2 scale lengths (disk maximality) is a robust observational indicator of the baryonic disk contribution to the potential. We construct the error budget for the key quantities: dynamical disk mass surface density ({Sigma}{sub dyn}), disk stellar mass-to-light ratio ({Upsilon}{sub *}{sup disk}), and disk maximality (F{sub *,max}{sup disk} {identical_to} V{sub *,max}{sup disk}/ V{sub c}). Random and systematic errors in these quantities for individual galaxies will be {approx}25%, while survey precision for sample quartiles are reduced to 10%, largely devoid of systematic errors outside of distance uncertainties.

79 ASTRONOMY AND ASTROPHYSICS↗

Ultrasensitive Superconducting Transition Edge Sensors Based On Electron-Phonon Decoupling

We have successfully fabricated the superconducting transition edge sensor (TES), bolometer technology that centers on the use of electron-phonon decoupling (EPD) to thermally isolate the bolometer. Along with material characterization for large format antenna coupled bolometer arrays, we present the initial test results of bolometer based on EPD designed for THz detection. We have selected a design approach that separates the two functions of photon absorption and temperature measurement, allowing separate optimization of the performance of each element. We have integrated Molybdenum/Gold (Mo/Au) bilayer TES and ion assisted thermally evaporated (IAE) Bismuth (Bi) films as radiation absorber coupled to a low-loss microstripline from Niobium (Nb) ground plane to a twin-slot antenna structure. The thermal conductance and the time constant of these devices have been measured, and are consistent with our calculations. The device exhibits a single time constant at 0.1 K of approx.160 IlS, which is compatible with readout by a high-bandwidth single SQUID or a time domain SQUID multiplexer. The effects of thermal conductance and electrothermal feedback are major determinants of the time constant, but the electronic heat capacity also plays a major role. The NEP achieved in the device described above is 2.5x10(exp -17)W(gamma)Hz. Our plan is to demonstrate a reduction of the volume in the superconducting element to 5 microns x 5 microns in films of half the thickness at Tc = 60mK. By calculation, this new geometry corresponds to an NEP reduction of two orders of magnitude to 2.5x10(exp -19)W/(gamma)Hz, with a time constant of ~130/ls.

Jethava, Nikhil↗

Effective detective quantum efficiency for two mammography systems: Measurement and comparison against established metrics

Purpose: The aim of this paper was to illustrate the value of the new metric effective detective quantum efficiency (eDQE) in relation to more established measures in the optimization process of two digital mammography systems. The following metrics were included for comparison against eDQE: detective quantum efficiency (DQE) of the detector, signal difference to noise ratio (SdNR), and detectability index (d′) calculated using a standard nonprewhitened observer with eye filter.Methods: The two systems investigated were the Siemens MAMMOMAT Inspiration and the Hologic Selenia Dimensions. The presampling modulation transfer function (MTF) required for the eDQE was measured using two geometries: a geometry containing scattered radiation and a low scatter geometry. The eDQE, SdNR, and d′ were measured for poly(methyl methacrylate) (PMMA) thicknesses of 20, 40, 60, and 70 mm, with and without the antiscatter grid and for a selection of clinically relevant target/filter (T/F) combinations. Figures of merit (FOMs) were then formed from SdNR and d′ using the mean glandular dose as the factor to express detriment. Detector DQE was measured at energies covering the range of typical clinically used spectra.Results: The MTF measured in the presence of scattered radiation showed a large drop at low spatial frequency compared to the low scatter method and led to a corresponding reduction in eDQE. The eDQE for the Siemens system at 1 mm{sup −1} ranged between 0.15 and 0.27, depending on T/F and grid setting. For the Hologic system, eDQE at 1 mm{sup −1} varied from 0.15 to 0.32, again depending on T/F and grid setting. The eDQE results for both systems showed that the grid increased the system efficiency for PMMA thicknesses of 40 mm and above but showed only small sensitivity to T/F setting. While results of the SdNR and d′ based FOMs confirmed the eDQE grid position results, they were also more specific in terms of T/F selection. For the Siemens system at 20 mm PMMA, the FOMs indicated Mo/Mo (grid out) as optimal while W/Rh (grid in) was the optimal configuration at 40, 60, and 70 mm PMMA. For the Hologic, the FOMs pointed to W/Rh (grid in) at 20 and 40 mm of PMMA while W/Ag (grid in) gave the highest FOM at 60 and 70 mm PMMA. Finally, DQE at 1 mm{sup −1} averaged for the four beam qualities studied was 0.44 ± 0.02 and 0.55 ± 0.03 for the Siemens and Hologic detectors, respectively, indicating only a small influence of energy on detector DQE.Conclusions: Both the DQE and eDQE data showed only a small sensitivity to T/F setting for these two systems. The eDQE showed clear preferences in terms of scatter reduction, being highest for the grid-in geometry for PMMA thicknesses of 40 mm and above. The SdNR and d′ based figures of merit, which contain additional weighting for contrast and dose, pointed to specific T/F settings for both systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thermomechanical design optimization for low metal footprint in hybrid metal-polymer heat exchanger

Material and maintenance costs of metal-based heat exchangers surpass profits in waste heat recovery (WHR) from ultra-low temperature (<100C) sources [1]. A low-cost alternative like polymer pipes suffer from poor thermal conductivity (~0.2 W/mK), and a low overall heat transfer coefficient. Polymers’ thermal conductivity have previously been enhanced through systematic molecular alignment by stretching [2], chemical vapor deposition of extended polymers [3], surface grating [4], etc. However, these approaches suffer from scalability issues for WHR heat exchangers in terms of cost [3], and thermomechanical considerations [5]. In this work, we propose novel hybrid metal-polymer heat exchangers that are made from polymer-copper strips. Through finite element method (FEM) simulations, we first optimize the placement of copper around polymer strips to enhance the transverse thermal conductivity of the strips. The copper cladded polymer strips are wound helically in a roll-to-roll system to form the pipes for a heat exchanger. We then optimize the design of helically wound pipes to reduce thermomechanical strains to < 0.2 % at 100C and 40 psi working conditions. At 25 % volume fraction of copper in the pipe, we predict up to 20 % enhancement in overall heat transfer from a base polymer with a thermal conductivity of 0.2 W/mK. We also compare and contrast the thermomechanical performance of the optimized metal-polymer strips to random metal matrix composites. Finally, we experimentally verify the thermal conductivity of the optimized strips through bulk thermal conductivity and thermal interface resistance measurement setup. By systematically improving the design through FEM and experimental measurements, we provide an optimized design of hybrid metal-polymer pipes that provides a low metal footprint and cost-effective means for harvesting waste heat from ultra-low temperature sources. Thekdi, Arvind, and Sachin U. Nimbalkar. Oak Ridge National Lab, 2015 Shen, Sheng, et al. Nature nanotechnology 5.4 (2010): 251. Xu, Yanfei, et al. Science advances 4.3 (2018): 3031. Smith, M. K., Singh, V., Kalaitzidou, K., & Cola, B. A. (2015). ACS nano, 9(2), 1080-1088. Aymonier, C., Bortzmeyer, D., Thomann, R., & M&uuml;lhaupt, R. (2003). Chemistry of Materials, 15(25), 4874-4878.

C Rajagopal, Manjunath↗

Development of Superconducting Transition Edge Sensors Based on Electron-Phonon Decoupling

We have successfully fabricated a superconducting transition edge sensor (TES), bolometer that centers on the use of electron-phonon decoupling (EPD) for thermal isolation. We have selected a design approach that separates the two functions of far-infrared and THz radiative power absorption and temperature measurement, allowing separate optimization of the performance of each element. We have integrated molybdenum/gold (Mo/Au) bilayer TES and ion assisted thermally evaporated (IAE) bismuth (Bi) films as radiation absorber coupled to a low-loss microstripline from niobium (Nb) ground plane to a twin-slot antenna structure. The thermal conductance (G) and the time constant for the different geometry device have been measured. For one such device, the measured G is 1.16 x 10(exp -10) W/K (plus or minus 0.61 x 10(exp- 10) W/K) at 60 mK, which corresponds to noise equivalent power (NEP) = 1.65 X 10(exp -18)W/vHz and time constant of approximately 5 microseconds.

Jethava, Nikhil↗

Optimizing complexity in the kinetic modelling of integrated flue gas purification for pressurized oxy-combustion

A 5-step mechanism and a corresponding kinetic model are presented for integrated flue gas purification, where SOx and NOx are removed during pressurized oxy-coal combustion. Three coupled subsystems (‘blocks”) of gas–liquid transformations are considered: 1) oxidation of NO to NO 2 and dissolution of NO 2 in water; 2) dissolution of SO 2 in the water; and 3) interactions between S- and N- containing substances in the liquid phase. The model has been formulated in terms of only species that can be experimentally measured (model of optimal complexity). Subsystem I is limiting regarding NO removal. Subsystem II is very fast in comparison with the other subsystems and can be treated separately. Analytical expressions for all independent subsystems have been found and compared with computational results for the whole system. The temporal domain of validity of all these subsystems is presented. Finally, the validity of the NO 2 quasi-steady-state assumption is verified, and it is reported that variables such as NO, NO 2 and HNO 3 can be considered decoupled from the whole system since they appear in only Subsystem I, while HSO 3 - and HNO 2 are coupled. The presented kinetic model was verified experimentally by determining the 1:1 ratio of HNO 2 and HNO 3 , in gas–liquid NO-O 2 interaction. Additionally, new experimental facts on kinetic orders and stoichiometry between HNO 2 and HSO 3 - have been used to optimize the model. It is concluded that all NO x - SO x interactions can be essentially grasped by a sequence of only 4 irreversible reactions considering, in addition, the 5th reaction, i.e. the fast ‘SO 2 -water’ equilibrium.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimization of in-line phase contrast particle image velocimetry using a laboratory x-ray source

Phase contrast particle image velocimetry (PIV) using a laboratory x-ray microfocus source is investigated using a numerical model. Phase contrast images of 75 {mu}m air bubbles, embedded within water exhibiting steady-state vortical flow, are generated under the paraxial approximation using a tungsten x-ray spectrum at 30 kVp. Propagation-based x-ray phase-contrast speckle images at a range of source-object and object-detector distances are generated, and used as input into a simulated PIV measurement. The effects of source-size-induced penumbral blurring, together with the finite dynamic range of the detector, are accounted for in the simulation. The PIV measurement procedure involves using the cross-correlation between temporally sequential speckle images to estimate the transverse displacement field for the fluid. The global error in the PIV reconstruction, for the set of simulations that was performed, suggests that geometric magnification is the key parameter for designing a laboratory-based x-ray phase-contrast PIV system. For the modeled system, x-ray phase-contrast PIV data measurement can be optimized to obtain low error (<0.2 effective pixel of the detector) in the system with magnification lying in the range between 1.5 and 3. For large effective pixel size (>15 {mu}m) of the detector, high geometric magnification (>2.5) is desired, while for large source size system (FWHM > 30 {mu}m), low magnification (<1.5) would be suggested instead. The methods developed in this paper can be applied to optimizing phase-contrast velocimetry using a variety of laboratory x-ray sources.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Determination of the Relative Amount of Fluorine in Uranium Oxyfluoride Particles using Secondary Ion Mass Spectrometry and Optical Spectroscopy

Both nuclear forensics and environmental sampling depend upon laboratory analysis of nuclear material that has often been exposed to the environment after it has been produced. It is therefore important to understand how those environmental conditions might have changed the chemical composition of the material over time, particularly for chemically sensitive compounds. In the specific case of uranium enrichment facilities, uranium-bearing particles stem from small releases of uranium hexafluoride, a highly reactive gas that hydrolyzes upon contact with moisture from the air to form uranium oxyfluoride (UO{sub 2}F{sub 2}) particles. The uranium isotopic composition of those particles is used by the International Atomic Energy Agency (IAEA) to verify whether a facility is compliant with its declarations. The present study, however, aims to demonstrate how knowledge of time-dependent changes in chemical composition, particle morphology and molecular structure can contribute to an even more reliable interpretation of the analytical results. We prepared a set of uranium oxyfluoride particles at the Institute for Reference Materials and Measurements (IRMM, European Commission, Belgium) and followed changes in their composition, morphology and structure with time to see if we could use these properties to place boundaries on the particle exposure time in the environment. Because the rate of change is affected by exposure to UV-light, humidity levels and elevated temperatures, the samples were subjected to varying conditions of those three parameters. The NanoSIMS at LLNL was found to be the optimal tool to measure the relative amount of fluorine in individual uranium oxyfluoride particles. At PNNL, cryogenic laser-induced time-resolved U(VI) fluorescence microspectroscopy (CLIFS) was used to monitor changes in the molecular structure.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Identifying Green Solvent Mixtures for Bioproduct Separation Using Bayesian Experimental Design

Liquid–liquid extraction (LLE) is a widely used technique for the separation and purification of liquid-phase products with applications in various industries, including pharmaceuticals, petrochemicals, and renewable chemistry. A critical step in the design of an LLE process is the selection of appropriate solvents. This study presents a new methodology for identifying solvent mixtures for bioproduct separation using Bayesian experimental design (BED). Motivated by the need for environmentally friendly and effective separation methods, we address the challenge of selecting solvent systems that balance separation efficiency, selectivity, and environmental impact while also tackling the difficulty of separating multiple bioproducts using complex solvent systems. Our approach specifically seeks to predict product partition coefficients (log10 Kp values) as thermodynamic parameters underlying solvent selection. The iterative approach integrates Bayesian optimization with experimental measurements to guide solvent selection and leverages COSMO-RS simulations to enhance high-throughput experimentation. Using the design of solvent systems for the separation of lignin-derived aromatic products via centrifugal partition chromatography (CPC) as a case study, we show that within seven iterations/cycles of the methodology, we can identify new mixtures of green solvents that align with CPC design principles. Furthermore, these results demonstrate the efficacy of the BED framework in optimizing green solvent systems for complex separations, highlighting the potential of this method to advance the field of green chemistry and contribute to the development of sustainable industrial processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermomechanical Design Optimization of Roll-to-Roll Manufactured Hybrid Metal Polymer Heat Exchanger

Metal based heat exchangers for ultra-low temperature (<100C) waste heat recovery (WHR) face high maintenance and material costs that surpass profits from recovery[1]. Low-cost polymer pipes suffer from poor thermal conductivity (~0.2 W/mK), and thus a low overall heat transfer coefficient. Thermal conductivity of polymers can be enhanced through systematic molecular alignment by stretching[2], chemical vapor deposition of extended polymers [3], surface grating [4], etc. However, these approaches suffer from scalability issues for WHR heat exchangers in terms of cost [3], and thermomechanical considerations [5]. In this work, we propose novel hybrid metal-polymer strips that are strategically designed to enhance thermal conductivity by cladding copper around polymer strips. The polymer strips with copper-clad edges are wound helically to form the pipes for a heat exchanger. Through finite element simulations, we optimize the design for enhanced thermal performance of the polymer-metal strips. We predict up to 20 % enhancement in overall heat transfer from a base polymer with a thermal conductivity of 0.2 W/mK. We show that the thermomechanical strains induced in the pipes can be reduced to < 0.2 % by strategically stacking and welding multiple polymer-metal strips. We verified the improved thermal performance of the roll-to-roll manufactured strips through a thermal conductivity measurement setup. The optimized design of hybrid metal-polymer pipes provides a scalable and cost-effective means for harvesting waste heat from ultra-low temperature sources. Thekdi, Arvind, and Sachin U. Nimbalkar. Oak Ridge National Lab, 2015 Shen, Sheng, et al. Nature nanotechnology 5.4 (2010): 251. Xu, Yanfei, et al. Science advances 4.3 (2018): 3031. Smith, M. K., Singh, V., Kalaitzidou, K., & Cola, B. A. (2015). ACS nano, 9(2), 1080-1088. Aymonier, C., Bortzmeyer, D., Thomann, R., & Mülhaupt, R. (2003). Chemistry of Materials, 15(25), 4874-4878.

C Rajagopal, Manjunath↗

Joint Non-Parametric Correction Estimator for Excess Relative Risk Regression in Survival Analysis with Exposure Measurement Error

Summary Observational epidemiological studies often confront the problem of estimating exposure–disease relationships when the exposure is not measured exactly. We investigate exposure measurement error in excess relative risk regression, which is a widely used model in radiation exposure effect research. In the study cohort, a surrogate variable is available for the true unobserved exposure variable. The surrogate variable satisfies a generalized version of the classical additive measurement error model, but it may or may not have repeated measurements. In addition, an instrumental variable is available for individuals in a subset of the whole cohort. We develop a non-parametric correction estimator by using data from the subcohort and further propose a joint non-parametric correction estimator using all observed data to adjust for exposure measurement error. An optimal linear combination estimator of the joint non-parametric correction and non-parametric correction is further developed. The estimators proposed are non-parametric, which are consistent without imposing a covariate or error distribution, and are robust to heteroscedastic errors. Finite sample performance is examined via a simulation study. We apply the developed methods to data from the Radiation Effects Research Foundation, in which chromosome aberration is used to adjust for the effects of radiation dose measurement error on the estimation of radiation dose responses.

Wang, Ching-Yun↗

Optimized beam sculpting with generalized fringe-rate filters

We generalize the technique of fringe-rate filtering, whereby visibilities measured by a radio interferometer are re-weighted according to their temporal variation. As the Earth rotates, radio sources traverse through an interferometer’s fringe pattern at rates that depend on their position on the sky. Capitalizing on this geometric interpretation of fringe rates, we employ time-domain convolution kernels to enact fringe-rate filters that sculpt the effective primary beam of antennas in an interferometer. As we show, beam sculpting through fringe-rate filtering can be used to optimize measurements for a variety of applications, including mapmaking, minimizing polarization leakage, suppressing instrumental systematics, and enhancing the sensitivity of power-spectrum measurements. We show that fringe-rate filtering arises naturally in minimum variance treatments of many of these problems, enabling optimal visibility-based approaches to analyses of interferometric data that avoid systematics potentially introduced by traditional approaches such as imaging. Our techniques have recently been demonstrated in Ali et al., where new upper limits were placed on the 21 cm power spectrum from reionization, showcasing the ability of fringe-rate filtering to successfully boost sensitivity and reduce the impact of systematics in deep observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of ORRUBA: A Silicon Array for the Measurement of Transfer Reactions in Inverse Kinematics

The development of high quality radioactive beams has made possible the measurement of transfer reactions in inverse kinematics on unstable nuclei. Measurement of (d,p) reactions on neutron-rich nuclei yield data on the evolution of nuclear structure away from stability, and are of astrophysical interest. Experimentally, (d,p) reactions on heavy (Z=50) fission fragments are complicated by the strongly inverse kinematics, and relatively low beam intensities. Consequently, ejectile detection with high resolution in position and energy, a high dynamic range and a high solid angular coverage is required. The Oak Ridge Rutgers University Barrel Array (ORRUBA) is a new silicon detector array optimized for the measurement of (d,p) reactions in inverse kinematics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High‐throughput combinatorial approach expedites the synthesis of a lead‐free relaxor ferroelectric system

Abstract Developing novel lead‐free ferroelectric materials is crucial for next‐generation microelectronic technologies that are energy efficient and environment friendly. However, materials discovery and property optimization are typically time‐consuming due to the limited throughput of traditional synthesis methods. In this work, we use a high‐throughput combinatorial synthesis approach to fabricate lead‐free ferroelectric superlattices and solid solutions of (Ba 0.7 Ca 0.3 )TiO 3 (BCT) and Ba(Zr 0.2 Ti 0.8 )O 3 (BZT) phases with continuous variation of composition and layer thickness. High‐resolution x‐ray diffraction (XRD) and analytical scanning transmission electron microscopy (STEM) demonstrate high film quality and well‐controlled compositional gradients. Ferroelectric and dielectric property measurements identify the “optimal property point” achieved at the composition of 48BZT–52BCT. Displacement vector maps reveal that ferroelectric domain sizes are tunable by varying {BCT–BZT} N superlattice geometry. This high‐throughput synthesis approach can be applied to many other material systems to expedite new materials discovery and properties optimization, allowing for the exploration of a large area of phase space within a single growth. image

36 MATERIALS SCIENCE↗

Integrating human factors issues into critical portable detection usage - 121

There are multiple situations where portable detection systems are used to quantify distributed radionuclides. Such applications include holdup measurements in decommissioning activities, other routine usage and safeguards applications. Human factors dominate equipment deployment and operation and have significant impact upon the resulting data collection and its quality. Equipment use includes simultaneous positioning and targeting the object/region being quantified, observation and reporting of incoming data, often in difficult conditions and often while dressed in protective equipment. We examine the human interface with the equipment and other human factors where balance, perception, situational awareness and personnel health level influence the physical control and positioning of the detector. All these aspects impact both the measurement outcome and the Total Measurement Uncertainty (TMU). In this work, we are developing approaches and solutions to: 1. Initiate an inclusive program to assess and evolve human factors aspects of the interface to provide real time feedback tailored to a specific field operator profile. 2. Develop a measurement system human interface on a 'bench top' detection system to allow for both audio and visual I/O for auditory attention and situational (objective and subjective) awareness across varied end user characteristics. 3. Assess and develop an enhanced health assessment plan to identify and monitor pertinent auditory and balance characteristics for operator(s) interface and physical control of the gamma detector. Use the plan to verify personnel ability for effective deployment. We take a multidisciplinary approach to maximize accuracy, efficiency, and safety for the end-user to optimize project and measurement performance. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗