Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Demonstration of a novel technique to measure two-photon exchange effects in elastic e±p scattering

The discrepancy between proton electromagnetic form factors extracted using unpolarized and polarized scattering data is believed to be a consequence of two-photon exchange (TPE) effects. However, the calculations of TPE corrections have significant model dependence, and there is limited direct experimental evidence for such corrections. The TPE contributions depend on the sign of the lepton charge in e±p scattering, but the luminosities of secondary positron beams limited past measurement at large scattering angles, where the TPE effects are believe to be most significant. We present the results of a new experimental technique for making direct e±p comparisons, which has the potential to make precise measurements over a broad range in Q 2 and scattering angles. We use the Jefferson Laboratory electron beam and the Hall B photon tagger to generate a clean but untagged photon beam. The photon beam impinges on a converter foil to generate a mixed beam of electrons, positrons, and photons. A chicane is used to separate and recombine the electron and positron beams while the photon beam is stopped by a photon blocker. This provides a combined electron and positron beam, with energies from 0.5 to 3.2 GeV, which impinges on a liquid hydrogen target. The large acceptance CLAS detector is used to identify and reconstruct elastic scattering events, determining both the initial lepton energy and the sign of the scattered lepton. The data were collected in two days with a primary electron beam energy of only 3.3 GeV, limiting the data from this run to smaller values of Q 2 and scattering angle. Nonetheless, this measurement yields a data sample for e±p with statistics comparable to those of the best previous measurements. We have shown that we can cleanly identify elastic scattering events and correct for the difference in acceptance for electron and positron scattering. Because we ran with only one polarity for the chicane, we are unable to study the difference between the incoming electron and positron beams. This systematic effect leads to the largest uncertainty in the final ratio of positron to electron scattering: R=1.027±0.005±0.05 for < Q 2 >=0.206 GeV 2 and 0.830 ≤ ε ≤ 0.943. We have demonstrated that the tertiary e ± beam generated using this technique provides the opportunity for dramatically improved comparisons of e±p scattering, covering a significant range in both Q 2 and scattering angle. Combining data with different chicane polarities will allow for detailed studies of the difference between the incoming e + and e - beams.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Doppler Global Velocimeter Measurements of the Vortical Flow Above a Thin Delta Wing

A new measurement technique is being developed by NASA to measure off-surface flow fields. This method, Doppler global velocimetry, will allow quantification of complex three-dimensional flow fields at video camera rates. The entire flow field structure within a selected plane is measured simultaneously rather than by scanned, point-by-point measurements using conventional laser velocimetry. Data obtained using this technique will be used to correlate with other data sets for verification, and following verification, provide a quantified, highly detailed definition of the flow field. This will help to improve the understanding of fluid physics, supplement and broaden the database required to validate and refine computational fluid dynamics (CFD) models, and improve aircraft design methodology. To assess the capability of the technique, velocity measurements of the vortical flow field above a thin 75-degree delta wing were made in the NASA - Langley Basic Aerodynamics Research Tunnel. Preliminary comparisons of the results were made with similar measurements obtained using a three component laser velocimeter indicate that this technique is capable of describing the entire three - component velocity flow field simultaneously within a measurement plane in real time.

Usry, Jimmy W.↗

Flow Visualization and Laser Velocimetry for Wind Tunnels

The need for flow visualization and laser velocimetry were discussed. The purpose was threefold: (1) provide a state-of-the-art overview; (2) provide a forum for industry, universities, and government agencies to address problems in developing useful and productive flow visualization and laser velocimetry measurement techniques; and (3) provide discussion of recent developments and applications of flow visualization and laser velocimetry measurement techniques and instrumentation systems for wind tunnels including the 0.3-Meter Transonic Cryogenic Tunnel.

Hunter, W. W., Jr.↗

Fiber optic and laser sensors IV; Proceedings of the Meeting, Cambridge, MA, Sept. 22-24, 1986

The conference presents papers on industrial uses of fiber optic sensors, point and distributed polarimetric optical fiber sensors, fiber optic electric field sensor technology, micromachined resonant structures, single-mode fibers for sensing applications, and measurement techniques for magnetic field gradient detection. Consideration is also given to electric field meter and temperature measurement techniques for the power industry, the calibration of high-temperature fiber-optic microbend pressure transducers, and interferometric sensors for dc measurands. Other topics include the recognition of colors and collision avoidance in robotics using optical fiber sensors, the loss compensation of intensity-modulating fiber-optic sensors, and an embedded optical fiber strain tensor for composite structure applications.

De Paula, Ramon P.↗

Noncontact torque measurement using stroboscopic techniques

Noncontact torquemeter measures torsional deflection of rotating shaft and results are viewed on vernier scale. Magnitude of torque must be calculated from measured deflection. Device has no electric connections with the rotating member and is easy to use.

Leonard, W. H.↗

MATCHED-INDEX-OF-REFRACTION FLOW FACILITY FOR FUNDAMENTAL AND APPLIED RESEARCH

Significant challenges face reactor designers with regard to thermal hydraulic design and associated modeling for advanced reactor concepts. Computational thermal hydraulic codes solve only a piece of the core. There is a need for a whole core dynamics system code with local resolution to investigate and understand flow behavior with all the relevant physics and thermo-mechanics. The matched index of refraction (MIR) flow facility at Idaho National Laboratory (INL) has a unique capability to contribute to the development of validated computational fluid dynamics (CFD) codes through the use of state-of-the-art optical measurement techniques, such as Laser Doppler Velocimetry (LDV) and Particle Image Velocimetry (PIV). PIV is a non-intrusive velocity measurement technique that tracks flow by imaging the movement of small tracer particles within a fluid. At the heart of a PIV calculation is the cross correlation algorithm, which is used to estimate the displacement of particles in some small part of the image over the time span between two images. Generally, the displacement is indicated by the location of the largest peak. To quantify these measurements accurately, sophisticated processing algorithms correlate the locations of particles within the image to estimate the velocity (Ref. 1). Prior to use with reactor deign, the CFD codes have to be experimentally validated, which requires rigorous experimental measurements to produce high quality, multi-dimensional flow field data with error quantification methodologies. Computational thermal hydraulic codes solve only a piece of the core. There is a need for a whole core dynamics system code with local resolution to investigate and understand flow behavior with all the relevant physics and thermo-mechanics. Computational techniques with supporting test data may be needed to address the heat transfer from the fuel to the coolant during the transition from turbulent to laminar flow, including the possibility of an early laminarization of the flow (Refs. 2 and 3) (laminarization is caused when the coolant velocity is theoretically in the turbulent regime, but the heat transfer properties are indicative of the coolant velocity being in the laminar regime). Such studies are complicated enough that computational fluid dynamics (CFD) models may not converge to the same conclusion. Thus, experimentally scaled thermal hydraulic data with uncertainties should be developed to support modeling and simulation for verification and validation activities. The fluid/solid index of refraction matching technique allows optical access in and around geometries that would otherwise be impossible while the large test section of the INL system provides better spatial and temporal resolution than comparable facilities. Benchmark data for assessing computational fluid dynamics can be acquired for external flows, internal flows, and coupled internal/external flows for better understanding of physical phenomena of interest. The core objective of this study is to describe MIR and its capabilities, and mention current development areas for uncertainty quantification, mainly the uncertainty surface method and cross-correlation method. Using these methods, it is anticipated to establish a suitable approach to quantify PIV uncertainty for experiments performed in the MIR.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Challenges and Techniques in Measurements of Noise, Cryogenic Noise and Power in Millimeter-Wave and Submillimeter-Wave Amplifiers

We will present the topic of noise measurements, including cryogenic noise measurements, of Monolithic Microwave Integrated Circuit (MMIC) and Sub-Millimeter-Wave Monolithic Microwave Integrated Circuit (S-MMIC) amplifiers, both on-wafer, and interfaced to waveguide modules via coupling probes. We will also present an overview of the state-of-the-art in waveguide probe techniques for packaging amplifier chips, and discuss methods to obtain the lowest loss packaging techniques available to date. Linearity in noise measurements will be discussed, and experimental methods for room temperature and cryogenic noise measurements will be presented. We will also present a discussion of power amplifier measurements for millimeter-wave and submillimeter-wave amplifiers, and the tools and hardware needed for this characterization.

Samoska, Lorene↗

A new technique for measuring astrophysically important (alpha,p) reactions

Studying ({alpha},p) reactions of astrophysical interest with radioactive beams presents serious challenges because of the difficult nature of the target. We have developed a new approach for the measurement of ({alpha},p) reactions using heavy ion beams in inverse kinematics and have measured the {sup 4}He({sup 19}F,{sup 1}H){sup 22}Ne reaction as a demonstration. {sup 19}F beams were used at the Holifield Radioactive Ion Beam Facility (HRIBF) tandem accelerator in Oak Ridge National Laboratory (ORNL) to bombard a large scattering chamber filled with {sup 4}He gas. Recoiling protons from the reactions were detected by the large area annular silicon strip detector array (SIDAR). The {sup 19}F({alpha},p) and {sup 19}F({alpha},p') excitation functions were measured over the energy range of E{sub c.m.} {approx} 1-2.1 MeV, demonstrating the viability of the technique

43 PARTICLE ACCELERATORS↗

Reliable four-point flexion test and model for die-to-wafer direct bonding

For many years, wafer-to-wafer (W2W) direct bonding has been very developed particularly in terms of bonding energy measurement and bonding mechanism comprehension. Nowadays, die-to-wafer (D2W) direct bonding has gained significant attention, for instance, in photonics and microelectro-mechanics, which supposes controlled and reliable fabrication processes. So, whatever the stuck materials may be, it is not obvious whether bonded D2W structures have the same bonding strength as bonded W2W ones, because of possible edge effects of dies. For that reason, it has been strongly required to develop a bonding energy measurement technique which is suitable for D2W structures. In this paper, both D2W- and W2W-type standard SiO{sub 2}-to-SiO{sub 2} direct bonding samples are fabricated from the same full-wafer bonding. Modifications of the four-point flexion test (4PT) technique and applications for measuring D2W direct bonding energies are reported. Thus, the comparison between the modified 4PT and the double-cantilever beam techniques is drawn, also considering possible impacts of the conditions of measures such as the water stress corrosion at the debonding interface and the friction error at the loading contact points. Finally, reliability of a modified technique and a new model established for measuring D2W direct bonding energies is demonstrated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Transportable Gravity Gradiometer Based on Atom Interferometry

A transportable atom interferometer-based gravity gradiometer has been developed at JPL to carry out measurements of Earth's gravity field at ever finer spatial resolutions, and to facilitate high-resolution monitoring of temporal variations in the gravity field from ground- and flight-based platforms. Existing satellite-based gravity missions such as CHAMP and GRACE measure the gravity field via precise monitoring of the motion of the satellites; i.e. the satellites themselves function as test masses. JPL's quantum gravity gradiometer employs a quantum phase measurement technique, similar to that employed in atomic clocks, made possible by recent advances in laser cooling and manipulation of atoms. This measurement technique is based on atomwave interferometry, and individual laser-cooled atoms are used as drag-free test masses. The quantum gravity gradiometer employs two identical atom interferometers as precision accelerometers to measure the difference in gravitational acceleration between two points (Figure 1). By using the same lasers for the manipulation of atoms in both interferometers, the accelerometers have a common reference frame and non-inertial accelerations are effectively rejected as common mode noise in the differential measurement of the gravity gradient. As a result, the dual atom interferometer-based gravity gradiometer allows gravity measurements on a moving platform, while achieving the same long-term stability of the best atomic clocks. In the laboratory-based prototype (Figure 2), the cesium atoms used in each atom interferometer are initially collected and cooled in two separate magneto-optic traps (MOTs). Each MOT, consisting of three orthogonal pairs of counter-propagating laser beams centered on a quadrupole magnetic field, collects up to 10(exp 9) atoms. These atoms are then launched vertically as in an atom fountain by switching off the magnetic field and introducing a slight frequency shift between pairs of lasers to create a moving rest frame for the trapped atoms. While still in this moving-frame molasses, the laser frequencies are further detuned from the atomic resonance (while maintaining this relative frequency shift) to cool the atom cloud's temperature to 2 K or below, corresponding to an rms velocity of less than 2 cm/s. After launch, the cold atoms undergo further state and velocity selection to prepare for atom interferometry. The atom interferometers are then realized using laser-induced stimulated Raman transitions to perform the necessary manipulations of each atom, and the resulting interferometer phase is measured using laser-induced fluorescence for state-normalized detection. More than 20 laser beams with independent controls of frequency, phase, and intensity are required for this measurement sequence. This instrument can facilitate the study of Earth's gravitational field from surface and air vehicles, as well as from space by allowing gravity mapping from a low-cost, single spacecraft mission. In addition, the operation of atom interferometer-based instruments in space offers greater sensitivity than is possible in terrestrial instruments due to the much longer interrogation times available in the microgravity environment. A space-based quantum gravity gradiometer has the potential to achieve sensitivities similar to the GRACE mission at long spatial wavelengths, and will also have resolution similar to GOCE for measurement at shorter length scales.

Yu, Nan↗

Neutron Imaging Calibration to Measure Void Fraction

Void fraction is an intuitive parameter that describes the fraction of vapor in a two-phase flow. It appears as a key variable in most heat transfer and pressure drop correlations used to design evaporating and condensing heat exchangers, as well as determining charge inventory in refrigeration systems. Void fraction measurement is not straightforward, however, and assumptions on the invasiveness of the measuring technique must be made. Neutron radiography or neutron imaging has the potential to be a truly non-invasive void fraction measuring technique but has until recently only offered qualitative descriptions of two-phase flow, in terms of flow maldistributions, for example. This paper describes the calibration approach necessary to employ neutron imaging to measure steady-state void fraction. Experiments were conducted at the High Flux Isotope Reactor (HFIR) Cold Guide 1D neutron imaging facility at Oak Ridge National Laboratory (ORNL), Oak Ridge, TN, USA.

42 ENGINEERING↗

Steady-state low thermal resistance characterization apparatus: The bulk thermal tester

The reliability of microelectronic devices is largely dependent on electronic packaging, which includes heat removal. The appropriate packaging design therefore necessitates precise knowledge of the relevant material properties, including thermal resistance and thermal conductivity. Thin materials and high conductivity layers make their thermal characterization challenging. A steady state measurement technique is presented and evaluated with the purpose to characterize samples with a thermal resistance below 100 mm{sup 2} K/W. It is based on the heat flow meter bar approach made up by two copper blocks and relies exclusively on temperature measurements from thermocouples. The importance of thermocouple calibration is emphasized in order to obtain accurate temperature readings. An in depth error analysis, based on Gaussian error propagation, is carried out. An error sensitivity analysis highlights the importance of the precise knowledge of the thermal interface materials required for the measurements. Reference measurements on Mo samples reveal a measurement uncertainty in the range of 5% and most accurate measurements are obtained at high heat fluxes. Measurement techniques for homogeneous bulk samples, layered materials, and protruding cavity samples are discussed. Ultimately, a comprehensive overview of a steady state thermal characterization technique is provided, evaluating the accuracy of sample measurements with thermal resistances well below state of the art setups. Accurate characterization of materials used in heat removal applications, such as electronic packaging, will enable more efficient designs and ultimately contribute to energy savings.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Local measurements of the pedestal magnetic field profile throughout the ELM cycle on DIII-D

We report new high speed localized measurements of the pedestal magnetic field during the edge localized mode (ELM) cycle of a DIII-D High confinement mode (H-mode) discharge indicate a temporally and spatial complex redistribution of the edge current density profile, $j_{edge}$. The measurement technique extracts the magnetic field magnitude, $\textit{B}$, via the spectral separation of Stark-split neutral beam radiation in the pedestal. Single spatial channel measurements from a novel spatial heterodyne spectrometer are validated in discharges with core current profile changes. The technique measures Stark-splitting changes that imply $\textit{B}$ changes as small as 1 mT with high time resolution (50 μs). At normalized poloidal flux $ψ_n$ = 1.0, $\textit{B}$ appears saturated in the inter-ELM period and then rapidly decreases in <200 μs by ~1%, before edge recycling emission begins to increase. Radially inboard of $j_{edge}$, $\textit{B}$ increases at the ELM crash. The behavior is consistent with a rapid collapse of $j_{edge}$ at the ELM crash and subsequent pedestal recovery. In some discharges, at $ψ_n$ < 0.96, changes in $\textit{B}$ are observed throughout the ELM cycle. In others, $\textit{B}$ recovers and is relatively stable until a few ms leading up to the next crash. Measurements of $\textit{B}$ during the H-mode transition show a large increase at $ψ_n$ = 1 with little change at $ψ_n$ = 0.9, consistent with the formation of the edge bootstrap current density peak. The $ψ_n$ = 0.9 spectrum is complicated by predicted changes to the Stark component intensities with density at the L–H transition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An analysis of short pulse and dual frequency radar techniques for measuring ocean wave spectra from satellites

A four frequency moment characterization of backscatter from the near-vertical is applied to an analysis of the short pulse and dual frequency microwave techniques. The range reflectivity modulation spectrum closely approximates the directional wave slope spectrum, while harmonic distortion is small and is a minimum near 10 deg incidence. The short pulse measurement signal-to-noise ratio (SNR) is typically greater than the narrowband dual frequency SNR, with the difference being the ratio of the range beam extent to pulse length, minus the ratio of beam-limited to pulse-limited Doppler spreads. It is concluded that dual frequency measurements are basically impractical, although short pulse measurements are useful and can employ existing space-qualified microwave hardware.

Jackson, F. C.↗

Impact of calibration technique on measurement accuracy for the JET core charge-exchange system

The core charge-exchange diagnostic at the Joint European Torus (JET) provides measurements of the impurity ion temperature T{sub i}, toroidal velocity V{sub {phi}}, and impurity ion densities n{sub imp}, across the whole minor radius. A contribution to the uncertainty of the measured quantities is the error resulting from the multi-Gaussian fit and photon statistics, usually quoted for each measured data. Absolute intensity calibration and especially alignment of the viewing directions can introduce an important systematic error. The technique adopted at JET to reduce this systematic contribution to the error is presented in this paper. The error in T{sub i}, V{sub {phi}}, and n{sub imp} is then discussed depending on their use.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

THE HISTORY OF STAR FORMATION IN GALAXY DISKS IN THE LOCAL VOLUME AS MEASURED BY THE ADVANCED CAMERA FOR SURVEYS NEARBY GALAXY SURVEY TREASURY

We present a measurement of the age distribution of stars residing in spiral disks and dwarf galaxies. We derive a complete star formation history of the {approx}140 Mpc{sup 3} covered by the volume-limited sample of galaxies in the Advanced Camera for Surveys (ACS) Nearby Galaxy Survey Treasury (ANGST). The total star formation rate density history ({rho}{sub SFR}(t)) is dominated by the large spirals in the volume, although the sample consists mainly of dwarf galaxies. Our {rho}{sub SFR}(t) shows a factor of {approx}3 drop at z {approx} 2, in approximate agreement with results from other measurement techniques. While our results show that the overall {rho}{sub SFR}(t) has decreased since z {approx} 1, the measured rates during this epoch are higher than those obtained from other measurement techniques. This enhanced recent star formation rate appears to be largely due to an increase in the fraction of star formation contained in low-mass disks at recent times. Finally, our results indicate that despite the differences at recent times, the epoch of formation of {approx}50% of the stellar mass in dwarf galaxies was similar to that of {approx}50% of the stellar mass in large spiral galaxies (z {approx}> 2), despite the observed galaxy-to-galaxy diversity among the dwarfs.

79 ASTRONOMY AND ASTROPHYSICS↗