Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

[CO2 Budget and Atmospheric Rectification (COBRA) Over North America]

The purpose of the CO2 Budget and Rectification Airborne (COBRA) study was to assess terrestrial sources and sinks of carbon dioxide using an air-borne study. The study was designed to address the measurement gap between plot-scale direct flux measurements and background hemispheric-scale constraints and to refine techniques for measuring terrestrial fluxes at regional to continental scales. The initial funded effort (reported on here) was to involve two air-borne campaigns over North America, one in summer and one in winter. Measurements for COBRA (given the acronym C02BAR in the initial proposal) were conducted from the University of North Dakota Citation 11, a twin-engine jet aircraft capable of profiling from the surface to 12 km and cruising for up to 4 hours and 175m/s. Onboard instrumentation measured concentrations of CO2, CO, and H2O, and meteorological parameters at high rates. In addition, two separate flask sampling systems collected discrete samples for laboratory analysis of CO2,CO, CH4, N2O, SF6, H2, 13CO2, C18O16O,O2/N2, and Ar/N2. The project involved a collaboration between a number of institutions, including (but not limited to) Harvard, NOAA-CMDL, the University of North Dakota, and Scripps.

Source record↗

Effects of RAM Exposure on a Low Earth Orbit BroadBand Radiometer (BBR): CERES Experience and Implications for EarthCARE

In order to best detect real changes in the Earth's climate system it is estimated that space based instrumentation measuring the global Earth Radiation Budget (ERB) must remain calibrated with a stability of 0.3% per decade. This level of stability is beyond the specified accuracy of existing ERB programs such as the Clouds and the Earth's Radiant Energy System (CERES, using three broadband radiometric scanning channels: the shortwave (SW 0.3 - 5?m), total (0.3 - >100 micron), and window (8 - 12 micron)). When in low earth orbit, it has been shown that optical response to blue-UV radiance can be reduced significantly (> 3%) due to UV hardened contaminants deposited on the surface of the optics. Evidence suggests that exposure of telescope optics to the forward looking ram direction is the primary cause of this contamination build up. With typical onboard calibration lamps emitting very low energy in the blue-UV region, this darkening is not directly measurable using standard internal calibration techniques. This paper describes a study using a model of ram exposure induced contaminant deposition and darkening, in conjunction standard established in-flight vicarious and internal calibration techniques to derive the spectral shape of the darkening to which a broadband instrument is subjected. The results of the model when applied to the CERES instruments are shown. These findings are of great importance to the EarthCARE project, whose BBR uses one broadband telescope permanently looking forward at 45 degrees, with continual exposure to the ram direction. Specific attention may therefore be needed in the design of BBR optics and on-board calibration in order to prevent or compensate for the spectral darkening seen in the CERES project.

Matthews, Grant↗

A Miniaturized Laser Heterodyne Radiometer for Greenhouse Gas Measurements in the Atmospheric Column

Laser Heterodyne Radiometry is a technique adapted from radio receiver technology has been used to measure trace gases in the atmosphere since the 1960s.By leveraging advances in the telecommunications industry, it has been possible to miniaturize this technology.The mini-LHR (Miniaturized Laser Heterodyne Radiometer) has been under development at NASA Goddard Space flight Center since 2009. This sun-viewing instrument measures carbon dioxide and methane in the atmospheric column and operates in tandem with an AERONET sun photometer producing a simultaneous measure of aerosols. The mini-LHR has been extensively field tested in a range of locations ranging in the continental US as well as Alaska and Hawaii and now operates autonomously with sensitivities of approximately 0.2 ppmv and approximately10 ppbv, for carbon dioxide and methane respectively, for 10 averaged scans under clear sky conditions.

CO2↗

Magnetic deflection ion mass spectrometer experiment for atmosphere explorer

The magnetic ion mass spectrometer was carried aboard Atmosphere Explorer C and Atmosphere Explorer D. The instrument measures the relative abundance of ionic species with very high sensitivity and very high mass resolution. Thus isotopic ratios for various ion species can be examined and minor ion species such as O(++), N(++), and H(+) can be detected when their relative abundance is very small. These instruments functioned with no critical internal failures but the premature loss of the AE-D spacecraft after only a few months of operation has led to an emphasis of scientific achievement from AE-C. The very long lifetime of AE-C coupled with the prolonged time that this spacecraft spent near the F-region peak led to the accumulation of very large count numbers in the channeltron detectors.

Hoffman, J. H.↗

The airborne Laser Absorption Spectrometer - A new instrument of remote measurement of atmospheric trace gases

The Laser Absorption Spectrometer is a portable instrument developed by JPL for remote measurement of trace gases from an aircraft platform. It contains two carbon dioxide lasers, two optical heterodyne receivers, appropriate optics to aim the lasers at the ground and detect the backscattered energy, and signal processing and recording electronics. Operating in the differential-absorption mode, it is possible to monitor one atmospheric gas at a time and record the data in real time. The system can presently measure ozone, ethylene, water vapor, and chlorofluoromethanes with high sensitivity. Airborne measurements were made in early 1977 from the NASA/JPL twin-engine Beechcraft and in May 1977 from the NASA Convair 990 during the ASSESS-II Shuttle Simulation Study. These flights resulted in measurements of ozone concentrations in the lower troposphere which were compared with ground-based values provided by the Air Pollution Control District. This paper describes the details of the instrument and results of the airborne measurements.

Shumate, M. S.↗

The CU 2-D-MAX-DOAS instrument – Part 1: Retrieval of 3-D distributions of NO 2 and azimuth-dependent OVOC ratios

Here, we present an innovative instrument telescope and describe a retrieval method to probe three-dimensional (3-D) distributions of atmospheric trace gases that are relevant to air pollution and tropospheric chemistry. The University of Colorado (CU) two-dimensional (2-D) multi-axis differential optical absorption spectroscopy (CU 2-D-MAX-DOAS) instrument measures nitrogen dioxide (NO 2 ), formaldehyde (HCHO), glyoxal (CHOCHO), oxygen dimer (O 2 –O 2 , or O 4 ), and water vapor (H 2 O); nitrous acid (HONO), bromine monoxide (BrO), and iodine monoxide (IO) are among other gases that can in principle be measured. Information about aerosols is derived through coupling with a radiative transfer model (RTM). The 2-D telescope has three modes of operation: mode 1 measures solar scattered photons from any pair of elevation angle (–20° < EA < +90° or zenith; zero is to the horizon) and azimuth angle (–180° < AA < +180°; zero being north); mode 2 measures any set of azimuth angles (AAs) at constant elevation angle (EA) (almucantar scans); and mode 3 tracks the direct solar beam via a separate view port. Vertical profiles of trace gases are measured and used to estimate mixing layer height (MLH). Horizontal distributions are then derived using MLH and parameterization of RTM (Sinreich et al., 2013). NO 2 is evaluated at different wavelengths (350, 450, and 560 nm), exploiting the fact that the effective path length varies systematically with wavelength. The area probed is constrained by O 4 observations at nearby wavelengths and has a diurnal mean effective radius of 7.0 to 25 km around the instrument location; i.e., up to 1960 km 2 can be sampled with high time resolution. The instrument was deployed as part of the Multi-Axis DOAS Comparison campaign for Aerosols and Trace gases (MAD-CAT) in Mainz, Germany, from 7 June to 6 July 2013. We present first measurements (modes 1 and 2 only) and describe a four-step retrieval to derive (a) boundary layer vertical profiles and MLH of NO 2 ; (b) near-surface horizontal distributions of NO 2 ; (c) range-resolved NO 2 horizontal distribution measurements using an "onion-peeling" approach; and (d) the ratios HCHO to NO 2 ( R FN ), CHOCHO to NO 2 ( R GN ), and CHOCHO to HCHO ( R GF ) at 14 pre-set azimuth angles distributed over a 360° view. Three-dimensional distribution measurements with 2-D-MAX-DOAS provide an innovative, regional perspective of trace gases as well as their spatial and temporal concentration gradients, and they maximize information to compare near-surface observations with atmospheric models and satellites.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An intercomparison of aircraft instrumentation for tropospheric measurements of sulfur dioxide

As part of the NASA Tropospheric Chemistry Program, a series of field intercomparisons have been conducted to evaluate the state-of-the art for measuring key tropospheric species. One of the objectives of the third intercomparison campaign in this series, Chemical Instrumentation Test and Evaluation 3 (CITE 3), was to evaluate instrumentation for making reliable tropospheric aircraft measurements of sulfur dioxide, dimethyl sulfide, hydrogen sulfide, carbon disulfide, and carbonyl sulfide. This paper reports the results of the intercomparisons of five sulfur dioxide measurement methods ranging from filter techniques, in which samples collected in flight are returned to the laboratory for analyses (chemiluminescent or ion chromatographic), to near real-time, in-flight measurements via gas chromatographic, mass spectrometric, and chemiluminescent techniques. All techniques showed some tendency to track sizeable changes in ambient SO2 such as those associated with altitude changes. For SO2 mixing ratios in the range of 200 pptv to a few ppbv, agreement among the techniques varies from about 30% to several orders of magnitude, depending upon the pair of measurements intercompared. For SO2 mixing ratios less than 200 pptv, measurements from the techniques are uncorrelated. In general, observed differences in the measurement of standards do not account for the flight results. The CITE 3 results do not unambiguously identify one or more of the measurement techniques as providing valid or invalid SO2 measurements, but identify the range of 'potential' uncertainty in SO2 measurements reported by currently available instrumentation and as measured under realistic aircraft environments.

Gregory, Gerald L.↗

A round-robin gamma stereotactic radiosurgery dosimetry interinstitution comparison of calibration protocols

Purpose: Absorbed dose calibration for gamma stereotactic radiosurgery is challenging due to the unique geometric conditions, dosimetry characteristics, and nonstandard field size of these devices. Members of the American Association of Physicists in Medicine (AAPM) Task Group 178 on Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance have participated in a round-robin exchange of calibrated measurement instrumentation and phantoms exploring two approved and two proposed calibration protocols or formalisms on ten gamma radiosurgery units. The objectives of this study were to benchmark and compare new formalisms to existing calibration methods, while maintaining traceability to U.S. primary dosimetry calibration laboratory standards. Methods: Nine institutions made measurements using ten gamma stereotactic radiosurgery units in three different 160 mm diameter spherical phantoms [acrylonitrile butadiene styrene (ABS) plastic, Solid Water, and liquid water] and in air using a positioning jig. Two calibrated miniature ionization chambers and one calibrated electrometer were circulated for all measurements. Reference dose-rates at the phantom center were determined using the well-established AAPM TG-21 or TG-51 dose calibration protocols and using two proposed dose calibration protocols/formalisms: an in-air protocol and a formalism proposed by the International Atomic Energy Agency (IAEA) working group for small and nonstandard radiation fields. Each institution’s results were normalized to the dose-rate determined at that institution using the TG-21 protocol in the ABS phantom. Results: Percentages of dose-rates within 1.5% of the reference dose-rate (TG-21 + ABS phantom) for the eight chamber-protocol-phantom combinations were the following: 88% for TG-21, 70% for TG-51, 93% for the new IAEA nonstandard-field formalism, and 65% for the new in-air protocol. Averages and standard deviations for dose-rates over all measurements relative to the TG-21 + ABS dose-rate were 0.999 ± 0.009 (TG-21), 0.991 ± 0.013 (TG-51), 1.000 ± 0.009 (IAEA), and 1.009 ± 0.012 (in-air). There were no statistically significant differences (i.e., p > 0.05) between the two ionization chambers for the TG-21 protocol applied to all dosimetry phantoms. The mean results using the TG-51 protocol were notably lower than those for the other dosimetry protocols, with a standard deviation 2–3 times larger. The in-air protocol was not statistically different from TG-21 for the A16 chamber in the liquid water or ABS phantoms (p = 0.300 and p = 0.135) but was statistically different from TG-21 for the PTW chamber in all phantoms (p = 0.006 for Solid Water, 0.014 for liquid water, and 0.020 for ABS). Results of IAEA formalism were statistically different from TG-21 results only for the combination of the A16 chamber with the liquid water phantom (p = 0.017). In the latter case, dose-rates measured with the two protocols differed by only 0.4%. For other phantom-ionization-chamber combinations, the new IAEA formalism was not statistically different from TG-21. Conclusions: Although further investigation is needed to validate the new protocols for other ionization chambers, these results can serve as a reference to quantitatively compare different calibration protocols and ionization chambers if a particular method is chosen by a professional society to serve as a standardized calibration protocol.

07 ISOTOPE AND RADIATION SOURCES↗

An extensometer for axial strain measurement at high temperature

Most existing strain measuring instruments, important for the investigation of the mechanical behavior of metals at high temperature, have temperature, strain range, and size limitations. In this short note the authors give the design and construction of an extensometer with sufficient dynamic range and good stability over long periods of time, for measuring the longitudinal strain of plane specimens from 0.001 to 0.1 at temperatures up to 800 C.

Schmidt, J.↗

Development of In-Situation Radioactivity Inspection System for Food Materials

The impacts on the ocean of releases of radionuclides from the Fukushima nuclear power plants remain unclear. Korean people worry about radioactive contamination of Japanese and Korean sea products. Radioactive contamination of processed foodstuffs, livestock, sea products, farm products imported from Japan and fishes caught in coastal oceans of Korea has become an important social issue. Recently, there are also needs of inspection system for monitoring of public meals such like school feedings of kindergarten, elementary/middle/high school and university. Radioactivity inspections of food materials have been executed manually with portable measuring instruments or at labs using their samples. But, it's very important the radioactivity inspection should be performed at the field of feeding facilities. To protect the health of people from radioactivity contained in Japanese marine products imported to Korea, a system to inspect radioactivity in real time has been developed. The system is to measure the radioactivity level of farm and marine products and public meals continuously and automatically at inspection sites of an agency checking radiation of imported foodstuffs or school. The performance test of NaI(Tl) detector was examined using the quantified Cs-137 source 10 Bq/kg, 30 Bq/kg, 50 Bq/kg, 300 Bq/kg and 900 Bq/kg at Korea Research Institute of Standards and Science(KRISS). Source was put in a box and radioactivity was measured in the middle of the box. First of all, Background was measured and calibration was performed using the Cs-137 300 Bq and Ba-133 3700 Bq for 60 minutes. After setting the background and calibration data, tests of the Cs-137 10, 30, 50, 300, 900 Bq/kg were executed for 10 minutes. A peak-shaped graph is shown at the location of 662 KeV (80∼100 channel). This is due to the gamma radiation energy with 662 KeV emitted by the Cs-137. Because through KRISS examination, the MDA (minimum detectable activity) is about 23 Bq/kg, it is reasonable Cs-137 10 Bq/kg cannot be measured. And in cases of Cs-137 300 Bq/kg and 900 Bq/kg, there are some peak movement on the graph. It can be adjusted by controlling gain or high voltage. The examination was identified through the performance test (Cs-137 10, 30, 50, 300, 900 Bq/kg) at KRISS. In order to increase the measurement efficiency of Cs-137 and the system performance, database will be built up based on radioactivity measurement results from 10 to 300 Bq/kg with the unit 10. Thus, Cs-137 concentration of food materials can be identified below the maximum permissible concentration of 100 Bq/kg on a basis of the spectrum characteristic of Cs-137. Also, anxiety about radioactive contamination of foods after the Fukushima nuclear accident will be eased and trust of the radioactive inspection is expected definitely. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fracture hydromechanical response measured by fiber optic distributed acoustic sensing at milliHertz frequencies: Fracture Hydromechanics From DAS

A new method of measuring dynamic strain in boreholes was used to record fracture displacement in response to head oscillation. Fiber optic distributed acoustic sensing (DAS) was used to measure strain at mHz frequencies, rather than the Hz to kHz frequencies typical for seismic and acoustic monitoring. Fiber optic cable was mechanically coupled to the wall of a borehole drilled into fractured crystalline bedrock. Oscillating hydraulic signals were applied at a companion borehole 30 m away. The DAS instrument measured fracture displacement at frequencies of less than 1 mHz and amplitudes of less than 1 nm, in response to fluid pressure changes of less 20 Pa (2 mm H 2 O). Displacement was linearly related to the log of effective stress, a relationship typically explained by the effect of self-affine fracture roughness on fracture closure. These results imply that fracture roughness affects closure even when displacement is a million times smaller than the fracture aperture.

58 GEOSCIENCES↗

Simulating response versus scan angle characterization on OCI for the upcoming PACE mission

The Plankton, Aerosol, Cloud ocean Ecosystem (PACE) mission Ocean Color Instrument (OCI) is the next generation ocean color sensor following on from the SeaWiFS and VIIRS designs, to be launched into low Earth orbit in 2022. Like those heritage sensors, OCI has cross track scanning fore-optics, the reflectivity of which (referred to here as the response versus scan angle or RVS) must be characterized prior to launch. The expected test setup, component reflectivity measurements, instrument model, and heritage sensor testing were used to generate simulated RVS data. This simulated data set was then used to verify the functionality of the analysis software in preparation for the upcoming ground test campaign. The analysis software is designed to characterize the RVS for all OCI bands over the full range of scan angles to be measured on orbit as well as verify compliance with the sensor design requirements in near real-time.

PACE↗

Distributed Acoustic Sensing as a Distributed Hydraulic Sensor in Fractured Bedrock

Distributed acoustic sensing (DAS) was originally intended to measure oscillatory strain at frequencies of 1 Hz or more on a fiber optic cable. Recently, measurements at much lower frequencies have opened the possibility of using DAS as a dynamic strain sensor in boreholes. A fiber optic cable mechanically coupled to a geologic formation will strain in response to hydraulic stresses in pores and fractures. A DAS interrogator can measure dynamic strain in the borehole, which can be related to fluid pressure through the mechanical compliance properties of the formation. Because DAS makes distributed measurements, it is capable of both locating hydraulically active features and quantifying the fluid pressure in the formation. We present field experiments in which a fiber optic cable was mechanically coupled to two crystalline rock boreholes. The formation was stressed hydraulically at another well using alternating injection and pumping. The DAS instrument measured oscillating strain at the location of a fracture zone known to be hydraulically active. Rock displacements of less than 1 nm were measured. Laboratory experiments confirm that displacement is measured correctly. These results suggest that fiber optic cable embedded in geologic formations may be used to map hydraulic connections in three-dimensional fracture networks. A great advantage of this approach is that strain, an indirect measure of hydraulic stress, can be measured without beforehand knowledge of flowing fractures that intersect boreholes. The technology has obvious applications in water resources, geothermal energy, CO 2 sequestration, and remediation of groundwater in fractured bedrock.

54 ENVIRONMENTAL SCIENCES↗

Simplified Microwave Radiometer

Cost, weight, and size less than half of conventional radiometers. Ground-based instrument measures temperatures in upper atmosphere while correcting for liquid water in clouds. Addition of channel at 51 GHz to channels used for making upper-atmosphere temperature profiles adds little to cost of microwave radiometer. Eliminates need for separate water-vapor radiometer subsystem, with its attendant size, weight, and cost. Instrument light, compact, and portable and inexpensive enough for use in sensor arrays. Availability encourages use of microwave radiometry for routine weather forecasting.

Gary, Bruce L.↗

A low cost imaging displacement measurement system for spacecraft thermal vacuum testing

A low cost imaging displacement technique suitable for use in thermal vacuum testing was built and tested during thermal vacuum testing of the space infrared telescope facility (SIRTF, later renamed Spitzer infrared telescope facility). The problem was to measure the relative displacement of different portions of the spacecraft due to thermal expansion or contraction. Standard displacement measuring instrumentation could not be used because of the widely varying temperatures on the spacecraft and for fear of invalidating the thermal vacuum testing. The imaging system was conceived, designed, purchased, and installed in approximately 2 months at very low cost. The system performed beyond expectations proving that sub millimeter displacements could be measured from over 2 meters away. Using commercial optics it was possible to make displacement measurements down to 10 (mu)m. An automated image processing tool was used to process the data, which not only speeded up data reduction, but showed that velocities and accelerations could also be measured. Details of the design and capabilities of the system are discussed along with the results of the test on the observatory. Several images from the actual test are presented.

thermal vacuum↗

Predicting Clear-Air Turbulence From Microwave Radiometry

Proposed system combines microwave-instrument measurement of vertical temperature gradient with inertial navigation-system measurement of wind vector and provides warnings about time and severity of upcoming clear air turbulence (CAT), and indicates how to avoid it. Also saves fuel by making it unnecessary to detour around regions conservative forecasts indicate might contain CAT, instead, one navigates more efficiently by following altitude-avoidance advisories of proposed instrument.

Gary, Bruce L.↗

Status of Validation Program for Tropical Rainfall Measuring Mission (TRMM)

The Tropical Rainfall Measuring Mission (TRMM) is in its sixth year of operation. This successful research mission, a joint U.S./Japan effort, has become-a key element in the routine monitoring of global precipitation. The package of rain measuring instrumentation, including the first meteorological radar in space, continues to function perfectly, and with the increase in orbital altitude (from 350 km to 400 km) the mission will hopefully continue for a number of years. The validation effort has been a combination of routine use of 1) ground-based radar and raingauge measurements for comparison with the satellite-based estimates, 2) the use of field experiment data for evaluation of the satellite data products and investigation of some of the assumptions in the satellite retrievals, and 3) use of other comparison data sets, including atoll and buoy gauges over ocean and research and operational gauge data sets over land. The status of the program will be described along with "lessons learned". Near term plans for improved validation products and new thrusts related to validation of TRMM-based multi-satellite products that extend into middle latitudes will be outlined.

Adler, Robert↗

Smart Methane Emission Detection System Development (Final Report)

Working with the Department of Energy's National Energy Technology Laboratory, Southwest Research Institute® (SwRI®) developed a system to identify methane leaks reliably, accurately, and autonomously at critical midstream sections of the natural gas distribution network in real-time for the purpose of mitigating methane emissions using Optical Gas Imaging (OGI) cameras. SwRI's Smart Leak Detection – Methane (SLED/M) adds a high degree of automation to the process of methane leak detection to minimize sources of human error, minimize response time to a leak event, and maximize midstream visibility. Furthermore, SwRI has been working towards integrating Quantitative OGI (QOGI) capabilities into this existing technology. By leveraging Deep Learning, SwRI now has the capability to estimate fugitive emission leak rates quickly and reliably, which allows operators to detect emissions, quantify leak rate, prioritize repairs, and validate the repairs in a single instrument. The next generation QOGI technology leverages the same cameras used in Leak Detection and Repair (LDAR) programs, with improvements in safety and speed for traditional quantification-based repairs, ultimately leading to less overhead cost for the operators. The goals for this research were to develop two types of models with the following goals: Run in real-time on the edge (≥ 12 Hz), Classification: Achieve less than 5% false positive detection, Classification: Achieve ≥ 95% methane plume detection rate, Regression: achieve ≤ 10 standard cubic feet per hour (scfh) prediction > 70% of the time. In order to achieve these results, multiple infrared (IR) and other sensors were investigated in tandem with the midwave IR (MWIR) OGI to provide additional information to train the underlying models. Information on atmospheric conditions including humidity, temperature, pressure, and solar radiation was provided by a weather station. Several machine learning and deep learning architectures and methods, including looking at quantized classification networks and regressions networks, were explored. As further data was collected, curated, and labeled, it allowed for more refined regressive networks to be adequately trained, leading to better insight into the true flow rates being observed. An important valuable deliverable of this research effort was the development of an advanced network which underwent multiple iterations capable of giving a continuous output. The current network has a predicted mean average percentage error (MAPE) of 12.3% just outside our target goal of 10.00%, but an accuracy of 97.78% at ±50 scfh, well within the overall goal for the Department of Energy (DOE) program. Upon closer inspection, it was observed that more than 10% of datapoints contributing to the MAPE predictions were the result of low flow rate predictions and are beyond the sensitivity of instrument measurement as a result of normal operational variation and noise.

03 NATURAL GAS↗