Search NASA⌕ Search

SEARCH · Search NASA

Results for “Monte Carlo Simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

On the relationships between electron spot size, focal spot size, and virtual source position in Monte Carlo simulations

Purpose: Every year, new radiotherapy techniques including stereotactic radiosurgery using linear accelerators give rise to new applications of Monte Carlo (MC) modeling. Accurate modeling requires knowing the size of the electron spot, one of the few parameters to tune in MC models. The resolution of integrated megavoltage imaging systems, such as the tomotherapy system, strongly depends on the photon spot size which is closely related to the electron spot. The aim of this article is to clarify the relationship between the electron spot size and the photon spot size (i.e., the focal spot size) for typical incident electron beam energies and target thicknesses. Methods: Three electron energies (3, 5.5, and 18 MeV), four electron spot sizes (FWHM=0, 0.5, 1, and 1.5 mm), and two tungsten target thicknesses (0.15 and 1 cm) were considered. The formation of the photon beam within the target was analyzed through electron energy deposition with depth, as well as photon production at several phase-space planes placed perpendicular to the beam axis, where only photons recorded for the first time were accounted for. Photon production was considered for ''newborn'' photons intersecting a 45x45 cm{sup 2} plane at the isocenter (85 cm from source). Finally, virtual source position and ''effective'' focal spot size were computed by backprojecting all the photons from the bottom of the target intersecting a 45x45 cm{sup 2} plane. The virtual source position and focal spot size were estimated at the plane position where the latter is minimal. Results: In the relevant case of considering only photons intersecting the 45x45 cm{sup 2} plane, the results unambiguously showed that the effective photon spot is created within the first 0.25 mm of the target and that electron and focal spots may be assumed to be equal within 3-4%. Conclusions: In a good approximation photon spot size equals electron spot size for high energy X-ray treatments delivered by linear accelerators.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Structural analysis of WO 3 -TeO 2 glasses by neutron, high energy X-ray diffraction, reverse Monte Carlo simulations and XANES

The structure of WO 3 -TeO 2 glasses containing 15, 20 and 25 mol% WO 3 are studied by neutron diffraction (ND), high energy X-ray diffraction (XRD) and X-ray Absorption Near Edge spectroscopy (XANES). The short-range structural properties of glasses i.e. Te-O and W-O speciation, coordination number distributions, bond-lengths, and the O-Te-O, O-W-O and O-O-O bond angle distributions in the glass network are determined by the Reverse Monte Carlo (RMC) simulations of the ND and XRD data. RMC technique successfully determined all partial pair correlation functions and the coordination number distributions revealed that glass network consists predominantly of TeO 4 and WO 4 units with small amounts of triangular, penta and hexa co-ordinated units. The average W-O and Te-O bond lengths are in the ranges: 1.69-1.75 +/- 0.01 angstrom and 1.99-2.00 +/- 0.01 angstrom respectively. Both W-O and Te-O correlation peaks are asymmetrical, that indicate a distribution of their bond lengths in the respective structural units. The O-Te-O bond angle distribution has a peak at 107 +/- 2 degrees. Similarly the O-W-O bond angle distribution has a peak at 108 +/- 5 degrees. On increasing the WO3 concentration from 15 to 25 mol%, the average Te-O coordination number decreases from 3.80 to 3.61 +/- 0.02 due to the structural transformation: TeO 4 → TeO 3 , similarly the W-O coordination also decreases and is in the range: 3.79-3.67 +/- 0.02. XANES studies found that the oxidation state of Te and W ions in the glasses are 4 + and 6 + respectively.

36 MATERIALS SCIENCE↗

Kinetic Monte Carlo Simulations Unveil Synergic Effects at Work on Bifunctional Catalysts

The interaction among metal particles and the support in heterogeneous catalysis has been the subject of a large number of studies. Although strong metal–support interactions can lead to deleterious catalyst deactivation and the underlying mechanism is well understood, in other cases the effect may beneficially enhance the catalytic activity and/or selectivity with no clear picture of the chemistry involved. Strong metal–support interactions make Au nanoparticles dispersed on MoC a highly active catalyst for the low-temperature water-gas shift reaction (WGSR). In this work, by using kinetic Monte Carlo (kMC) simulations, we unravel the origin of the experimentally observed high WGSR activity of Au/MoC. The kMC simulations provide strong evidence for a cooperative effect between the different regions of the catalyst: the clean MoC regions are responsible for adsorbing and dissociating water molecules, and the vicinity of the Au adclusters contributes to COOH formation. The information thus obtained goes beyond that obtained solely from free-energy landscapes and constitutes a step forward toward the rational design of catalysts. Importantly, the simulations and analysis described here are general and can be applied to other complex systems involving different catalytic regions and a large number of surface processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SAXS-guided unbiased coarse-grained Monte Carlo simulation for identification of self-assembly nanostructures and dimensions

Recent studies have shown that solvated amphiphiles can form nanostructured self-assemblies called dynamic binary complexes (DBCs) in the presence of ions. Since the nanostructures of DBCs are directly related to their viscoelastic properties, it is important to understand how the nanostructures change under different solution conditions. However, it is challenging to obtain a three-dimensional molecular description of these nanostructures by utilizing conventional experimental characterization techniques or thermodynamic models. To this end, we combined the structural data from small angle X-ray scattering (SAXS) experiments and thermodynamic knowledge from coarse-grained Monte Carlo (CGMC) simulations to identify the detailed three-dimensional nanostructure of DBCs. Specifically, unbiased CGMC simulations are performed with SAXS-guided initial conditions, which aids us to sample accurate nanostructures in a computationally efficient fashion. As a result, an elliptical bilayer nanostructure is obtained as the most probable nanostructure of DBCs whose dimensions are validated by scanning electron microscope (SEM) images. Then, utilizing the obtained molecular model of DBCs, here we could also explain the pH tunability of the system. Overall, our results from SAXS-guided unbiased CGMC simulations highlight that using potential energy combined with SAXS data, we can distinguish otherwise degenerate nanostructures resulting from the inherent ambiguity of SAXS patterns.

36 MATERIALS SCIENCE↗

X-ray spectrum microanalysis of semiconductor epitaxial heterostructures on the basis of a monte carlo simulation of electron transport

Specific features of the X-ray spectrum microanalysis of semiconductor heterostructures based on III-V and II-VI alloys with thin epitaxial layers are considered. Simulation of electron transport on the basis of the Monte Carlo method is used to analyze the effect of the layer and substrate on the depth distribution of X-ray generation. Good agreement between the calculated and experimental values of the ratio between the intensities of emission from the layer and bulk sample for simulated Al{sub 0.2}Ga{sub 0.8}As structures on the GaAs substrate (with different thicknesses of the layer) is obtained. Methods allowing the performance of a correct microanalysis of the layers with thicknesses in excess of 50 nm and to determine simultaneously the composition and thickness of epitaxial layers are suggested. The methods developed can be used in the analysis of thin layers and in other systems.

36 MATERIALS SCIENCE↗

3D Visualization of Monte-Carlo Simulation's of HZE Track Structure and Initial Chemical Species

Heavy ions biophysics is important for space radiation risk assessment [1] and hadron-therapy [2]. The characteristic of heavy ions tracks include a very high energy deposition region close to the track (<20 nm) denoted as the track core, and an outer penumbra region consisting of individual secondary electrons (6-rays). A still open question is the radiobiological effects of 6- rays relative to the track core. Of importance is the induction of double-strand breaks (DSB) [3] and oxidative damage to the biomolecules and the tissue matrix, considered the most important lesions for acute and long term effects of radiation. In this work, we have simulated a 56Fe26+ ion track of 1 GeV/amu with our Monte-Carlo code RITRACKS [4]. The simulation results have been used to calculate the energy depiction and initial chemical species in a "voxelized" space, which is then visualized in 3D. Several voxels with dose >1000 Gy are found in the penumbra, some located ~0.1 mm from the track core. In computational models, the DSB induction probability is calculated with radial dose [6], which may not take into account the higher RBE of electron track ends for DSB induction. Therefore, these simulations should help improve models of DSB induction and our understanding of heavy ions biophysics.

Plante, Ianik↗

Kinetic Monte Carlo Simulations of Oxygen Diffusion in Environmental Barrier Coating Materials

Ceramic Matrix Composite (CMC) materials are of interest for use in next-generation turbine engine components, offering a number of significant advantages, including reduced weight and high operating temperatures. However, in the hot environment in which such components operate, the presence of water vapor can lead to corrosion and recession, limiting the useful life of the components. Such degradation can be reduced through the use of Environmental Barrier Coatings (EBCs) that limit the amount of oxygen and water vapor reaching the component. Candidate EBC materials include Yttrium and Ytterbium silicates. In this work we present results of kinetic Monte Carlo (kMC) simulations of oxygen diffusion, via the vacancy mechanism, in Yttrium and Ytterbium disilicates, along with a brief discussion of interstitial diffusion.

Good, Brian S.↗

Kinetic Monte Carlo Simulations of Oxygen Diffusion in Environmental Barrier Coating Materials

Ceramic Matrix Composite (CMC) materials are of interest for use in next-generation turbine engine components, offering a number of significant advantages, including reduced weight and high operating temperatures. However, in the hot environment in which such components operate, the presence of water vapor can lead to corrosion and recession, limiting the useful life of the components. Such degradation can be reduced through the use of Environmental Barrier Coatings (EBCs) that limit the amount of oxygen and water vapor reaching the component. Candidate EBC materials include Yttrium and Ytterbium silicates. In this work we present results of kinetic Monte Carlo (kMC) simulations of oxygen diffusion, via the vacancy mechanism, in Yttrium and Ytterbium disilicates, along with a brief discussion of interstitial diffusion. An EBC system typically includes a bond coat located between the EBC and the component surface. Bond coat materials are generally chosen for properties other than low oxygen diffusivity, but low oxygen diffusivity is nevertheless a desirable characteristic, as the bond coat could provide some additional component protection, particularly in the case where cracks in the coating system provide a direct path from the environment to the bond coat interface. We have therefore performed similar kMC simulations of oxygen diffusion in this material.

Good, Brian S.↗

A study on the neutron monitoring system of LHD based on Monte Carlo simulations

Neutron monitoring is quite important because fusion neutrons are a direct evidence of fusion reactions. In calibration experiments of a neutron monitoring system, Monte Carlo calculations play an important role to correct various effects. To perform Monte Carlo calculations for a helical type fusion device, we make a program that can automatically generate an input file of a helical coil geometry for the MCNP code. The neutron spatial distributions and spectra for the helical devices are calculated in the geometries automatically generated by this program. We also discuss in calibration experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Adsorption of simple square-well fluids in slit nanopores: Modeling based on Generalized van der Waals partition function and Monte Carlo simulation

A model based on the Generalized van der Waals partition function is derived to predict the adsorption of square-well fluid in slit pores of any size, the walls of which also have square-well potential. The space inside the pore is divided into several regions based on the extent of the attractive regions generated by the walls. Closed-form expressions of the chemical potentials of the confined fluid in different regions in the pore are obtained. The densities of fluid in different regions are calculated by equalizing the chemical potentials of fluid in those regions to that of the bulk phase. To examine the accuracy of the model, the Grand Canonical Monte Carlo (GCMC) simulation is also conducted. Here we find that the model well captures the effects of the bulk conditions and the properties of adsorbate and pore on the density of adsorbate in the pore. The model is also shown to be able to predict the adsorption of real gases in various activated carbons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Monte Carlo Simulations for Evaluating the Accuracy of GLM Detection Efficiency and False Alarm Rate Retrievals

The performance of the Geostationary Lightning Mapper has been evaluated through comparison with other satellite lightning sensors and ground-based networks. However, because the performance of these reference sensors is both imperfect and imperfectly known, the true performance of GLM can only be estimated through such a process. In particular, GLM performance metrics such as detection efficiency (DE) and false alarm rate (FAR) retrieved through comparison with reference networks are affected by those networks’ own DE, FAR, and spatiotemporal accuracy, as well as the selected flash matching criteria. This study presents follow-on results from an ongoing analysis that uses a Monte Carlo simulation-based inversion technique to quantify the effect on retrieved GLM performance of a reasonable range of reference network DE, FAR, spatiotemporal accuracy, and the associated geographic patterns of each. These results help quantify and bound the actual performance of GLM and the attendant uncertainties when comparing GLM to imperfect reference networks.

Katrina Virts↗

MONTE CARLO SIMULATIONS OF GLOBULAR CLUSTER EVOLUTION. V. BINARY STELLAR EVOLUTION

We study the dynamical evolution of globular clusters containing primordial binaries, including full single and binary stellar evolution using our Monte Carlo cluster evolution code updated with an adaptation of the single and binary stellar evolution codes SSE and BSE from Hurley et al. We describe the modifications that we have made to the code. We present several test calculations and comparisons with existing studies to illustrate the validity of the code. We show that our code finds very good agreement with direct N-body simulations including primordial binaries and stellar evolution. We find significant differences in the evolution of the global properties of the simulated clusters using stellar evolution compared with simulations without any stellar evolution. In particular, we find that the mass loss from the stellar evolution acts as a significant energy production channel simply by reducing the total gravitational binding energy and can significantly prolong the initial core contraction phase before reaching the binary-burning quasi-steady state of the cluster evolution. We simulate a large grid of models varying the initial cluster mass, binary fraction, and concentration parameter, and we compare properties of the simulated clusters with those of the observed Galactic globular clusters (GGCs). We find that simply including stellar evolution in our simulations and assuming the typical initial cluster half-mass radius is approximately a few pc independent of mass, our simulated cluster properties agree well with the observed GGC properties such as the core radius and the ratio of the core radius to the half-mass radius. We explore in some detail qualitatively different clusters in different phases of their evolution and construct synthetic Hertzsprung-Russell diagrams for these clusters.

79 ASTRONOMY AND ASTROPHYSICS↗

Kinetic Monte Carlo Simulations of Diffusion in Environmental Barrier Coating Materials

Ceramic Matrix Components (CMC) components for use in turbine engines offer a number of advantages compared with current practice. However, such components are subject to degradation through a variety of mechanisms. In particular, in the hot environment inside a turbine in operation a considerable amount of water vapor is present, and this can lead to corrosion and recession. Environmental Barrier Coating (EBC) systems that limit the amount of oxygen and water reaching the component are required to reduce this degradation and extend component life. A number of silicate-based materials are under consideration for use in such coating systems, including Yttterbium and Yttrium di- and monosilicates. In this work, we present results of kinetic Monte Carlo computer simulations of oxygen diffusion in Yttrium disilicate, and compare with previous work on Yttterbium disilicate. Coatings may also exhibit cracking, and the cracks can provide a direct path for oxygen to reach the component. There is typically a bond coat between the coating and component surface, but the bond coat material is generally chosen for properties other than low oxygen diffusivity. Nevertheless, the degree to which the bond coat can inhibit oxygen diffusion is of interest, as it may form the final defense against oxygen impingement on the component. We have therefore performed similar simulations of oxygen diffusion through HfSiO4, a proposed bond coat material.

Computer Simulation↗

Kinetic Monte Carlo Simulation of Oxygen Diffusion in Ytterbium Disilicate

Silicon-based ceramic components for next-generation jet turbine engines offer potential weight savings, as well as higher operating temperatures, both of which lead to increased efficiency and lower fuel costs. Silicon carbide (SiC), in particular, offers low density, good strength at high temperatures, and good oxidation resistance in dry air. However, reaction of SiC with high-temperature water vapor, as found in the hot section of jet turbine engines in operation, can cause rapid surface recession, which limits the lifetime of such components. Environmental Barrier Coatings (EBCs) are therefore needed if long component lifetime is to be achieved. Rare earth silicates such as Yb2Si2O7 and Yb2SiO5 have been proposed for such applications; in an effort to better understand diffusion in such materials, we have performed kinetic Monte Carlo (kMC) simulations of oxygen diffusion in Ytterbium disilicate, Yb2- Si2O7. The diffusive process is assumed to take place via the thermally activated hopping of oxygen atoms among oxygen vacancy sites or among interstitial sites. Migration barrier energies are computed using density functional theory (DFT).

Computer Simulation↗

SU-E-T-289: Scintillating Fiber Based In-Vivo Dose Monitoring System to the Rectum in Proton Therapy of Prostate Cancer: A Geant4 Monte Carlo Simulation

Purpose: To construct a dose monitoring system based on an endorectal balloon coupled to thin scintillating fibers to study the dose delivered to the rectum during prostate cancer proton therapy Methods: The Geant4 Monte Carlo toolkit version 9.6p02 was used to simulate prostate cancer proton therapy treatments of an endorectal balloon (for immobilization of a 2.9 cm diameter prostate gland) and a set of 34 scintillating fibers symmetrically placed around the balloon and perpendicular to the proton beam direction (for dosimetry measurements) Results: A linear response of the fibers to the dose delivered was observed within <2%, a property that makes them good candidates for real time dosimetry. Results obtained show that the closest fiber recorded about 1/3 of the dose to the target with a 1/r{sup 2} decrease in the dose distribution as one goes toward the frontal and distal top fibers. Very low dose was recorded by the bottom fibers (about 45 times comparatively), which is a clear indication that the overall volume of the rectal wall that is exposed to a higher dose is relatively minimized. Further analysis indicated a simple scaling relationship between the dose to the prostate and the dose to the top fibers (a linear fit gave a slope of −0.07±0.07 MeV per treatment Gy) Conclusion: Thin (1 mm × 1 mm × 100 cm) long scintillating fibers were found to be ideal for real time in-vivo dose measurement to the rectum for prostate cancer proton therapy. The linear response of the fibers to the dose delivered makes them good candidates of dosimeters. With thorough calibration and the ability to define a good correlation between the dose to the target and the dose to the fibers, such dosimeters can be used for real time dose verification to the target.

60 APPLIED LIFE SCIENCES↗

Complete Monte Carlo Simulation of Neutron Scattering Experiments

In the far past, it was not possible to accurately correct for the finite geometry and the finite sample size of a neutron scattering set-up. The limited calculation power of the ancient computers as well as the lack of powerful Monte Carlo codes and the limitation in the data base available then prevented a complete simulation of the actual experiment. Using e.g. the Monte Carlo neutron transport code MCNPX [1], neutron scattering experiments can be simulated almost completely with a high degree of precision using a modern PC, which has a computing power that is ten thousand times that of a super computer of the early 1970s. Thus, (better) corrections can also be obtained easily for previous published data provided that these experiments are sufficiently well documented. Better knowledge of reference data (e.g. atomic mass, relativistic correction, and monitor cross sections) further contributes to data improvement. Elastic neutron scattering experiments from liquid samples of the helium isotopes performed around 1970 at LANL happen to be very well documented. Considering that the cryogenic targets are expensive and complicated, it is certainly worthwhile to improve these data by correcting them using this comparatively straightforward method. As two thirds of all differential scattering cross section data of {sup 3}He(n,n){sup 3}He are connected to the LANL data, it became necessary to correct the dependent data measured in Karlsruhe, Germany, as well. A thorough simulation of both the LANL experiments and the Karlsruhe experiment is presented, starting from the neutron production, followed by the interaction in the air, the interaction with the cryostat structure, and finally the scattering medium itself. In addition, scattering from the hydrogen reference sample was simulated. For the LANL data, the multiple scattering corrections are smaller by a factor of five at least, making this work relevant. Even more important are the corrections to the Karlsruhe data due to the inclusion of the missing outgoing self-attenuation that amounts to up to 15%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear data verification based on Monte Carlo simulations of the LLNL pulsed-sphere benchmark experiments (1979 & 1986) using the Mercury code

Livermore's nuclear data group developed a new verification and validation test suite to ensure the quality of data used in application codes. This is based on models of LLNL's pulsed sphere fusion shielding benchmark experiments. Simulations were done with Mercury, a 3D particle transport Monte Carlo code using continuous-energy cross-section libraries. Results were compared to measurements of neutron leakage spectra generated by 14MeV neutrons in 17 target assemblies (for a blank target assembly, H{sub 2}O, Teflon, C, N{sub 2}, Al, Si, Ti, Fe, Cu, Ta, W, Au, Pb, {sup 232}Th, {sup 235}U, {sup 238}U, and {sup 239}Pu). We also tested the fidelity of simulations for photon production associated with neutron interactions in the different materials. Gamma-ray leakage energy per neutron was obtained from a simple 1D spherical geometry assembly and compared to three codes (TART, COG, MCNP5) and several versions of the Evaluated Nuclear Data File (ENDF) and Evaluated Nuclear Data Libraries (ENDL) cross-section libraries. These tests uncovered a number of errors in photon production cross-sections, and were instrumental to the V&V of different cross-section libraries. Development of the pulsed sphere tests also uncovered the need for new Mercury capabilities. To enable simulations of neutron time-of-flight experiments the nuclear data group implemented an improved treatment of biased angular scattering in MCAPM.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗