Search NASA⌕ Search

SEARCH · Search NASA

Results for “Motion Segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Monte Carlo calculation of helical tomotherapy dose delivery

Helical tomotherapy delivers intensity modulated radiation therapy using a binary multileaf collimator (MLC) to modulate a fan beam of radiation. This delivery occurs while the linac gantry and treatment couch are both in constant motion, so the beam describes, from a patient/phantom perspective, a spiral or helix of dose. The planning system models this continuous delivery as a large number (51) of discrete gantry positions per rotation, and given the small jaw/fan width setting typically used (1 or 2.5 cm) and the number of overlapping rotations used to cover the target (pitch often <0.5), the treatment planning system (TPS) potentially employs a very large number of static beam directions and leaf opening configurations to model the modulated fields. All dose calculations performed by the system employ a convolution/superposition model. In this work the authors perform a full Monte Carlo (MC) dose calculation of tomotherapy deliveries to phantom computed tomography (CT) data sets to verify the TPS calculations. All MC calculations are performed with the EGSnrc-based MC simulation codes, BEAMnrc and DOSXYZnrc. Simulations are performed by taking the sinogram (leaf opening versus time) of the treatment plan and decomposing it into 51 different projections per rotation, as does the TPS, each of which is segmented further into multiple MLC opening configurations, each with different weights that correspond to leaf opening times. Then the projection is simulated by the summing of all of the opening configurations, and the overall rotational treatment is simulated by the summing of all of the projection simulations. Commissioning of the source model was verified by comparing measured and simulated values for the percent depth dose and beam profiles shapes for various jaw settings. The accuracy of the MLC leaf width and tongue and groove spacing were verified by comparing measured and simulated values for the MLC leakage and a picket fence pattern. The validated source and MLC configuration were then used to simulate a complex modulated delivery from fixed gantry angle. Further, a preliminary rotational treatment plan to a delivery quality assurance phantom (the 'cheese' phantom) CT data set was simulated. Simulations were compared with measured results taken with an A1SL ionization chamber or EDR2 film measurements in a water tank or in a solid water phantom, respectively. The source and MLC MC simulations agree with the film measurements, with an acceptable number of pixels passing the 2%/1 mm gamma criterion. 99.8% of voxels of the MC calculation in the planning target volume (PTV) of the preliminary plan passed the 2%/2 mm gamma value test. 87.0% and 66.2% of the voxels in two organs at risk (OARs) passed the 2%/2 mm tests. For a 3%/3 mm criterion, the PTV and OARs show 100%, 93.2%, and 86.6% agreement, respectively. All voxels passed the gamma value test with a criterion of 5%/3 mm. The TomoTherapy TPS showed comparable results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design and Testing of a Novel Wide Range - Segmented Gamma Scanner Incorporating Tomographic Gamma Scanning for Measuring Both Low and Intermediate Level Waste in Drums - 13470

This paper describes the design and testing of a novel automated Wide Range Segmented Gamma ray Scanning (WR-SGS) assay instrument that also incorporates Tomographic Gamma Scanning (TGS). The instrument is designed for the measurement of both Low and Intermediate Level Waste (LLW and ILW) in 200 litre drums and other waste containers covering a wide range of density. Like earlier ANTECH WR-SGS instruments, the system employs a single shielded and collimated high purity germanium (HPGe) detector to quantify the radionuclide content of the waste and like conventional SGS instruments it is suitable for the measurement of relatively homogeneous waste matrices. Also, like earlier WR-SGS systems the instrument incorporates an automated variable aperture collimator, which allows the vertical segment height to be adjusted in order to measure both high dose-rate and very low activity drums. The instrument employs both conventional discrete SGS vertical segment measurements as well as vertical segment measurement by continuous helical-scanning of the drum as it rotates. This latter method reduces measurement times for SGS measurements. In order to determine the density corrections for both low and high-density drums, a high activity Eu-152 transmission source is employed. When not in use, and in place of a conventional shutter mechanism, the shielded transmission source is moved to a shielded storage position to eliminate background radiation from the source. Due to its novel features, the WR-SGS is applicable to the measurement of both very low and very high activity waste drums as well as waste drums with a wide range of density. If located in a low background position and with the effective shielding of the strong transmission source, the instrument can be used to measure very low level or exempt waste. In order to extend the range of applicability to the measurement of heterogeneous drums, TGS measurement capability has been included in the basic WR-SGS design. This is achieved by adding horizontal motion to the waste drum rotation platform and incorporating TGS collimation into the variable aperture collimator, as well as a filter to reduce the detector signal when straight-through measurements are made using the strong transmission source. Test measurements are presented of the system operating in both SGS and TGS modes using different drum densities and source strengths. The test measurement results are compared with benchmarked MCNP Monte Carlo calculations. The Wide Range SGS - TGS instrument extends the range of both activity and density that can be measured in 200 and 340 litre drums. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Methodology issues concerning the accuracy of kinematic data collection and analysis using the ariel performance analysis system

Kinematics, the study of motion exclusive of the influences of mass and force, is one of the primary methods used for the analysis of human biomechanical systems as well as other types of mechanical systems. The Anthropometry and Biomechanics Laboratory (ABL) in the Crew Interface Analysis section of the Man-Systems Division performs both human body kinematics as well as mechanical system kinematics using the Ariel Performance Analysis System (APAS). The APAS supports both analysis of analog signals (e.g. force plate data collection) as well as digitization and analysis of video data. The current evaluations address several methodology issues concerning the accuracy of the kinematic data collection and analysis used in the ABL. This document describes a series of evaluations performed to gain quantitative data pertaining to position and constant angular velocity movements under several operating conditions. Two-dimensional as well as three-dimensional data collection and analyses were completed in a controlled laboratory environment using typical hardware setups. In addition, an evaluation was performed to evaluate the accuracy impact due to a single axis camera offset. Segment length and positional data exhibited errors within 3 percent when using three-dimensional analysis and yielded errors within 8 percent through two-dimensional analysis (Direct Linear Software). Peak angular velocities displayed errors within 6 percent through three-dimensional analyses and exhibited errors of 12 percent when using two-dimensional analysis (Direct Linear Software). The specific results from this series of evaluations and their impacts on the methodology issues of kinematic data collection and analyses are presented in detail. The accuracy levels observed in these evaluations are also presented.

Wilmington, R. P.↗

MODELING THE OUTFLOW IN THE NARROW-LINE REGION OF MARKARIAN 573: BICONICAL ILLUMINATION OF A GASEOUS DISK

We present a study of the outflowing ionized gas in the resolved narrow-line region of the Seyfert 2 galaxy Mrk 573, and its interaction with an inner dust/gas disk, based on Hubble Space Telescope (HST) Wide Field Planetary Camera 2 and Space Telescope Imaging Spectrograph observations. From the spectroscopic and imaging information, we determined the fundamental geometry of the outflow and inner disk, via two modeling programs used to recreate the morphology of these regions imaged with HST. We also determined that the bicone of ionizing radiation from the active galactic nucleus intersects with the inner disk, illuminating a section of the disk including inner segments of spiral arms, fully seen through structure mapping, which appear to be outflowing and expanding. In addition, we see high velocities at projected distances of {>=}2'' ({approx}700 pc) from the nucleus, which could be due to rotation or in situ acceleration of gas off the spiral arms. We find that the true half-opening angle of the ionizing bicone (53{sup 0}) is much larger than the apparent half-opening angle (34{sup 0}) due to the above geometry, which may apply to a number of other Seyferts as well.

79 ASTRONOMY AND ASTROPHYSICS↗

Reconstruction of implanted marker trajectories from cone-beam CT projection images using interdimensional correlation modeling

Purpose: Cone-beam CT (CBCT) is a widely used imaging modality for image-guided radiotherapy. Most vendors provide CBCT systems that are mounted on a linac gantry. Thus, CBCT can be used to estimate the actual 3-dimensional (3D) position of moving respiratory targets in the thoracic/abdominal region using 2D projection images. The authors have developed a method for estimating the 3D trajectory of respiratory-induced target motion from CBCT projection images using interdimensional correlation modeling. Methods: Because the superior–inferior (SI) motion of a target can be easily analyzed on projection images of a gantry-mounted CBCT system, the authors investigated the interdimensional correlation of the SI motion with left–right and anterior–posterior (AP) movements while the gantry is rotating. A simple linear model and a state-augmented model were implemented and applied to the interdimensional correlation analysis, and their performance was compared. The parameters of the interdimensional correlation models were determined by least-square estimation of the 2D error between the actual and estimated projected target position. The method was validated using 160 3D tumor trajectories from 46 thoracic/abdominal cancer patients obtained during CyberKnife treatment. The authors’ simulations assumed two application scenarios: (1) retrospective estimation for the purpose of moving tumor setup used just after volumetric matching with CBCT; and (2) on-the-fly estimation for the purpose of real-time target position estimation during gating or tracking delivery, either for full-rotation volumetric-modulated arc therapy (VMAT) in 60 s or a stationary six-field intensity-modulated radiation therapy (IMRT) with a beam delivery time of 20 s. Results: For the retrospective CBCT simulations, the mean 3D root-mean-square error (RMSE) for all 4893 trajectory segments was 0.41 mm (simple linear model) and 0.35 mm (state-augmented model). In the on-the-fly simulations, prior projections over more than 60° appear to be necessary for reliable estimations. The mean 3D RMSE during beam delivery after the simple linear model had established with a prior 90° projection data was 0.42 mm for VMAT and 0.45 mm for IMRT. Conclusions: The proposed method does not require any internal/external correlation or statistical modeling to estimate the target trajectory and can be used for both retrospective image-guided radiotherapy with CBCT projection images and real-time target position monitoring for respiratory gating or tracking.

60 APPLIED LIFE SCIENCES↗

Tracking the Relative Motion of Four Space Payloads Launched from a Sub-Orbital NASA Rocket

One problem, which is comparatively new in the field of GPS applications, is the determination of the relative trajectories of space vehicles. Applications include the docking of spacecraft, collision avoidance in the area of space stations, and trajectory reconstruction of multiple payloads. The required precision in any of these applications will vary, according to the requirements of the task and abilities of GPS to cope with the environment and the dynamics. This paper describes the post-mission reconstruction of the relative trajectories of four GPS receivers attached to four payloads jettisoned from a Black Brant XII rocket. This vehicle was launched by the National Aeronautics and Space Administration (NASA) in January 1999 from the Poker Flats Research Range near Fairbanks, Alaska. The Black Brant XII is a sub-orbital rocket designed to carry payloads of 100 to 500 kg into the upper atmosphere. Flight time is generally in the order of 10-20 minutes. In this experiment, a GPS receiver and antenna was attached to each of the four payloads. One of the GPS receivers was assigned as the "base station", while the other 3 receivers were designated as remotes. GPS time, code and phase measurements were telemetered to a ground station for real-time processing and storage. The object of the mission was to re-compute the position and velocity of the remote units with respect to the base station during the launch phase and after the payloads separated. During the launch segment the 3 baseling distances between the 4 antennas are known from plans and are constant values until each payload is released. On the fly ambiguity determination was used to establish local coordinates from the base antenna to each of the other 3 GPS units during flight. Distance computations were made from the GPS-derived coordinates and compared to plan distances. Using this methodology an error analysis of the relative GPS accuracies has been presented and in addition a description given of the respective payload behaviour following separation from the vehicle.

Martell, Hugh↗

The Structure of A Pacific Narrow Cold Frontal Rainband

A NOAA P-3 instrumented aircraft observed an intense, fast-moving narrow cold frontal Farmhand as it approached the Pacific Northwest coast on 19 February 2001 during the Pacific Coastal Jets Experiment. Pseudo-dual-Doppler analyses performed on the airborne Doppler radar data while the frontal system was well offshore indicated that a narrow ribbon of very high radar reflectively convective cores characterized the Farmhand at low levels with echo tops to approximately 4-5 km. The NCFR exhibited gaps in its narrow ribbon of high reflectively, probably as a result of hydrodynamic instability all no its advancing cold pool leading edge. In contrast to some earlier studies of cold frontal rainbands, density current theory described well the motion of the overall front. The character of the updraft structure associated with the heavy rainfall at its leading edge varied across the gap region. The vertical shear of the cross-frontal low-level ambient flow exerted a strong influence on the updraft character, consistent with theoretical arguments developed for squall lines describing the balance of vorticity at the leading edge. In short regions south of the gaps the vertical wind shear was strongest with the updrafts and rain shafts more intense, narrower, and more erect or even downshear tilted. North of the gaps the wind shear weakened with less intense Dihedrals which tilted upshear with a broader band of rainfall. Simulations using a nonhydrostatic mesoscale nested grid model are used to investigate the gap regions, particularly the balance of cold pool induced to pre-frontal ambient shears at the leading edge. Observations confirm the model results that the updraft character depends on the balance of vorticity at the leading edge. Downshear-tilted updrafts imply that convection south of the gap regions would weaken with time relative to the frontal segments north of the gaps since inflow air would be affected by passage through the heavy rain region before ascent, suggesting a mechanism for gap filling.

Jorgensen, David P.↗

Effects of Tethered Polymers on Dynamics of Nanoparticles in Unentangled Polymer Melts

Polymer-tethered nanoparticles (NPs) are commonly added to a polymer matrix to improve the material properties. Critical to the fabrication and processing of such composites is the mobility of the tethered NPs. Here, we study the motion of tethered NPs in unentangled polymer melts using molecular dynamics simulations, which offer a precise control of the grafted chain length N g and the number z of grafted chains per particle. As Ng increases, there is a crossover from particle-dominated to tethered-chain-dominated terminal diffusion of NPs with the same z. The mean squared displacement of loosely tethered NPs in the case of tethered-chain-dominated terminal diffusion exhibits two subdiffusive regimes at intermediate time scales for small z. The first one at shorter time scales arises from the dynamical coupling of the particle and matrix chains, while the one at longer time scales is due to the participation of the particle in the dynamics of the tethered chains. The friction of loosely grafted chains in unentangled melts scales linearly with the total number of monomers in the chains, as the friction of individual monomers is additive in the absence of hydrodynamic coupling. As more chains are grafted to a particle, hydrodynamic interactions between grafted chains emerge. As a result, there is a nondraining layer of hydrodynamically coupled chain segments surrounding the bare particle. Outside the nondraining layer is a free-draining layer of grafted chain segments with no hydrodynamic coupling. The boundary of the two layers is the stick surface where the shear stress due to the relative melt flow is balanced by the friction between the grafted and melt chains in the interpenetration layer. The stick surface is located further away from the bare surface of the particle with higher grafting density.

42 ENGINEERING↗

A physically based mechanical model for Mullins effect in thermoplastic polyurethanes

Despite decades of research, connecting the chemical and physical structure of thermoplastic polyurethanes to their mechanical properties remains highly challenging. Of particular note are their large-deformation and rate-dependent behaviors, which vary greatly with molecular chemistry, including the type and relative content of soft and hard segments. In this work, we develop a physically motivated mechanical theory for predicting the behavior of thermoplastic polyurethanes. The theory incorporates a representation of microstructural evolution during mechanical deformation, which captures the signatures of stress softening over cyclic loading (commonly referred to as the Mullins effect). There are only eight physically motivated fitting parameters, including a direct dependence on the hard segment fraction. The model predicts that increasing the hard segment fraction leads to higher stiffness and greater energy dissipation, in quantitative agreement with published experimental data. Furthermore, we provide a comprehensive analysis of the model and validate its predictions across several independent datasets focused on mechanical characterization. Direct comparisons to experimental data demonstrate its predictive capability on the effect of loading rate, cyclic deformations, and applied tension or compression. Altogether, this work establishes a predictive framework that connects polymer chemistry and microstructure to emergent mechanical behaviors.

36 MATERIALS SCIENCE↗

Microscopic Theory of Long-Time Center-of-Mass Self-Diffusion and Anomalous Transport in Ring Polymer Liquids

We construct a microscopic theory at the level of segment-scale correlated space–time intermolecular forces for the long-time center-of-mass (CM) diffusion constant and intermediate-time non-Fickian transport in dense solutions and melts of ring polymers. The approach combines ideas of polymer, colloid, and liquid-state statistical mechanics to quantify how the multifractal intra-ring conformational structure and inter-ring packing correlations determine dynamic caging constraints and time-dependent friction. Breakdown of Rouse theory is predicted to occur due to length scale-dependent temporal correlation of forces exerted on pairs of tagged ring segments from surrounding polymers. At large enough degrees of polymerization (N), a stronger scaling of the CM diffusion constant (D ∝ N –2 ) is predicted, with a crossover N D proportional to the product of the system-specific macromolecular volume fraction and dimensionless compressibility. In analogy with caging effects in glass-forming fluids, the theory does appear to begin to fail at sufficiently high N/N D for the center-of-mass diffusivity, likely due to another crossover to an even slower activated transport regime. However, use of N/N D with the theoretically predicted N D , in conjunction with dynamic blob scaling ideas for local Rouse friction, collapses semidilute and concentrated solution simulation data onto a master curve. Based on the same physical ideas employed to predict the diffusion constant, a generalized Langevin equation description is formulated for intermediate-time CM transport. It predicts two subdiffusive regimes that emerge due to the self-similar nature of internal ring structure. Analytic and numerical predictions for the apparent non-Fickian exponent as a function of time, N/N D and dimensionless compressibility, the evolution of the maximum degree of subdiffusive motion with N/N D , and the time scale for recovering Fickian diffusion are made, all of which are in good accordance with melt simulations. Furthermore, the present work sets the stage to address activated dynamics and glass formation on the macromolecular scale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-J-78: Internal Target Volume Delineation for Lung Tumors in Patients Treated with Robotic Radiosurgery

Purpose: To compare different approaches for Internal Target Volume (ITV) delineation for patients treated with fiducial-free robotic radiosurgery for primary and metastatic lung tumors. Methods: Ten patients undergoing Lung-Optimized Treatment (LOT) for robotic radiosurgery were imaged with inhale and exhale breath-hold CT scans and 8-phase 4DCT scan. We evaluated the differences in internal target volume (ITV) delineated using three approaches: 1) maximum intensity projection (MIP) images reconstructed from 4DCT scan (ITV-MIP); 2) linear interpolation of Gross Tumor Volumes (GTV) segmented on inhale and exhale breath-hold scans (ITV-BH); 3) linear interpolation of GTV segmented on inhale and exhale phases of 4DCT scan (ITV-2Phase). All contours were independently generated by the same radiation oncologist using lung window settings. Patients had ITV-MIP volumes ranging from 1.5 to 146.9 cc (mean 36.8 cc) located in various parts of the lung. Volume overlap and matching index (MI) were calculated and compared. The MI between two volumes was defined as the ratio of their intersection to their union. MI of 1 indicates the volumes are identical; MI of 0 indicates that there is no overlap. Results: The three approaches generated very different results. The average (SD) MI for ITV-MIP and ITV-BH was 0.52 (0.24); for ITV-MIP and ITV-2Phase it was 0.69 (0.13); and for ITV-BH and ITV-2Phase was 0.57 (0.21), (ANOVA, p=0.16). Relative to the ITV-MIP, the percentage of volume overlap was 72% (26%) and 90% (7%) for ITV-BH and ITV-2Phase, respectively (t-test, p=0.05). Conclusion: Differences between ITV-BH and ITV-MIP are due to inconsistent lung filling at breath-hold and nonlinear tumor motion. Therefore, methods to check breath-hold scanning against regular patient breathing patterns should be developed. Whenever possible, ITV-BH generated by the LOT workflow should be verified by 4DCT data.

60 APPLIED LIFE SCIENCES↗

A set of 4D pediatric XCAT reference phantoms for multimodality research

Purpose: The authors previously developed an adult population of 4D extended cardiac-torso (XCAT) phantoms for multimodality imaging research. In this work, the authors develop a reference set of 4D pediatric XCAT phantoms consisting of male and female anatomies at ages of newborn, 1, 5, 10, and 15 years. These models will serve as the foundation from which the authors will create a vast population of pediatric phantoms for optimizing pediatric CT imaging protocols. Methods: Each phantom was based on a unique set of CT data from a normal patient obtained from the Duke University database. The datasets were selected to best match the reference values for height and weight for the different ages and genders according to ICRP Publication 89. The major organs and structures were segmented from the CT data and used to create an initial pediatric model defined using nonuniform rational B-spline surfaces. The CT data covered the entire torso and part of the head. To complete the body, the authors manually added on the top of the head and the arms and legs using scaled versions of the XCAT adult models or additional models created from cadaver data. A multichannel large deformation diffeomorphic metric mapping algorithm was then used to calculate the transform from a template XCAT phantom (male or female 50th percentile adult) to the target pediatric model. The transform was applied to the template XCAT to fill in any unsegmented structures within the target phantom and to implement the 4D cardiac and respiratory models in the new anatomy. The masses of the organs in each phantom were matched to the reference values given in ICRP Publication 89. The new reference models were checked for anatomical accuracy via visual inspection. Results: The authors created a set of ten pediatric reference phantoms that have the same level of detail and functionality as the original XCAT phantom adults. Each consists of thousands of anatomical structures and includes parameterized models for the cardiac and respiratory motions. Based on patient data, the phantoms capture the anatomic variations of childhood, such as the development of bone in the skull, pelvis, and long bones, and the growth of the vertebrae and organs. The phantoms can be combined with existing simulation packages to generate realistic pediatric imaging data from different modalities. Conclusions: The development of patient-derived pediatric computational phantoms is useful in providing variable anatomies for simulation. Future work will expand this ten-phantom base to a host of pediatric phantoms representative of the public at large. This can provide a means to evaluate and improve pediatric imaging devices and to optimize CT protocols in terms of image quality and radiation dose.

61 RADIATION PROTECTION AND DOSIMETRY↗

Secondary Fragmentation of Comet Shoemaker-Levy 9 and the Ramifications for the Progenitor's Breakup in July 1992

Comprehensive analysis of discrete events of secondary fragmentation leads to a conceptually new understanding of the process of disintegration of comet Shoemaker-Levy 9. We submit that the jovian tidal forces inflicted extensive cracks throughout the interior of the original nucleus but did not split it apart. The initial disruption was apparently accomplished by stresses exerted on the cracked object by its fast rotation during the early post-perijove period of time. We argue that this disruption was in fact a rapid sequence of episodes during July 1992 that gave birth to the 12 on-train, or primary, fragments: A, C, D, E, G, H, K, L, Q (later Q(sub 1)), R, S, and W. The discrete events of secondary fragmentation, which gave birth to the off-train fragments, are understood in this scenario as stochastic manifestations of the continuing process of progressive disintegration. Of the 13 off-train fragments considered, nine were secondary--B, F, G(sub 2), M, N, P (later P(sub 2) or P(sub 2a)), Q(sub 2), U, and V--and four tertiary (J, P(sub 1), P(sub 2b), and T). The separation parameters of 11 off-train fragments were determined. The vectorial distribution of separation velocities of these fragments shows a strong concentration toward a great circle, unquestionably an effect of the approximately conserved angular momentum of the progenitor comet since the time of its initial disruption. Also apparent is their clumping (except for P(sub 1)) to a segment along the great circle, implying that the fragments were consistently released from one side of their parents, thus explaining for the first time why the off-train fragments preferentially appeared on one side of the nuclear train. In order to obtain a consistent solution, our model requires that the points of separation be on the antisolar side of the parent fragments, where thermal stresses are likely to enhance the effect of rotation. The episodes of secondary fragmentation are found to have nine months after the close encounter with Jupiter in early July 1992, and the separation velocities ranged between 0.36 and 1.7 m/s. The spin-axis position is determined to have been nearly in the jovicentric orbit plane, which rules out the Asphaug-Benz-Solem strengthless aggregate model as a plausible breakup hypothesis. Since the separation velocities are rotational in nature, they cannot substantially exceed the critical limit for centrifugal breakup and offer an estimate for the original nuclear dimensions. The comet's nucleus is found to have been approximately 10 km in diameter and spinning rapidly. With the exception of P(sub 1) and apparently also P(sub 2) and F, no nongravitational deceleration was detected in the motions of the off-train fragments. Serious doubts are cast on continuing appreciable activity of any of these fragments. Indeed, when it was necessary to introduce a deceleration into the equations of motion, the effect appears to have been due to the action of solar radiation pressure on the centroid of centimeter-sized particulates in the disintegrating condensations.

Sekanina, Z.↗

3D Scanning System to Assess Gravity-Dependent Body Shape Changes

The human body shows unique physiological and morphological changes when exposed to different gravity conditions, including muscle atrophy, fluid shift, spinal elongation, and body posture adjustments. Such changes need to be incorporated for human-system integration in the vehicle habitat, garment, and spacesuit designs, as inaccurate body measurements can result in suboptimal crew protection that can potentially decrease injury tolerance. However, the traditional linear measurements, such as stature, segment lengths or circumferences measured using a caliper or tape measure, often show limited consistency and are unable to capture the nonlinear characteristics of the human body. While 3D body scanning can provide significant advantages over linear measurements, the technologies have not been fully developed or customized for in-flight scanning. For ground laboratory use, several different scanner types are commercially available. However, in-flight scanning requires additional technical considerations, such as minimal scan time, simplified calibration, and sufficient capture volume. This work aims to develop a prototype 3-D body scanning system that is customized for in-flight use to scan crewmembers, with the configuration and performance optimized for detecting known gravity-dependent body shape and posture changes. A hardware system will be custom built using a network of commercial off-the-shelf 3D sensors. The sensor parameters and settings will be optimized to detect the targeted body shape changes, specifically using body manikins of which the shape and size are iteratively permuted to simulate the known changes by fluid shift and spinal elongation. The capture volume will be also matched for a range of body sizes from a 1st percentile female to 99th percentile male. Unintentional body motions or floating in microgravity will be also simulated and incorporated. A data acquisition software will be developed for efficient in-flight operations with minimal overhead and easy-to-use user interface. A simplified calibration procedure will be designed for robust scanning against frequent vibration or unexpected sensor position shifts. The system will be tested in the ground laboratory for accuracy and reliability against a reference scanning system. New anthropometry measurements will be also identified to sensitively capture the gravity dependent body shape changes, in addition to the traditional anthropometry measurements. A novel landmark-based technique will be tested for consistent anthropometry measurements across posture variations. If successfully developed and deployed, the new system is expected to provide previously unavailable body shape and size data from different gravitational environments, including 0-g, 1/6-g, and 1-g. Such data can improve suit fit, habitat design, exercise efficacy quantification and sizing of orthostatic intolerance garments.

K H Kim↗

3D Scanning System to Assess Gravity-Dependent Body Shape Changes

The human body shows unique physiological and morphological changes when exposed to different gravity conditions, including muscle atrophy, fluid shift, spinal elongation, and body posture adjustments. Such changes need to be incorporated for human-system integration in the vehicle habitat, garment, and spacesuit designs, as inaccurate body measurements can result in suboptimal crew protection that can potentially decrease injury tolerance. However, the traditional linear measurements, such as stature, segment lengths or circumferences measured using a caliper or tape measure, often show limited consistency and are unable to capture the nonlinear characteristics of the human body. While 3D body scanning can provide significant advantages over linear measurements, the technologies have not been fully developed or customized for in-flight scanning. For ground laboratory use, several different scanner types are commercially available. However, in-flight scanning requires additional technical considerations, such as minimal scan time, simplified calibration, and sufficient capture volume. This work aims to develop a prototype 3-D body scanning system that is customized for in-flight use to scan crewmembers, with the configuration and performance optimized for detecting known gravity-dependent body shape and posture changes. A hardware system will be custom built using a network of commercial off-the-shelf 3D sensors. The sensor parameters and settings will be optimized to detect the targeted body shape changes, specifically using body manikins of which the shape and size are iteratively permuted to simulate the known changes by fluid shift and spinal elongation. The capture volume will be also matched for a range of body sizes from a 1st percentile female to 99th percentile male. Unintentional body motions or floating in microgravity will be also simulated and incorporated. A data acquisition software will be developed for efficient in-flight operations with minimal overhead and easy-to-use user interface. A simplified calibration procedure will be designed for robust scanning against frequent vibration or unexpected sensor position shifts. The system will be tested in the ground laboratory for accuracy and reliability against a reference scanning system. New anthropometry measurements will be also identified to sensitively capture the gravity dependent body shape changes, in addition to the traditional anthropometry measurements. A novel landmark-based technique will be tested for consistent anthropometry measurements across posture variations. If successfully developed and deployed, the new system is expected to provide previously unavailable body shape and size data from different gravitational environments, including 0-g, 1/6-g, and 1-g. Such data can improve suit fit, habitat design, exercise efficacy quantification and sizing of orthostatic intolerance garments.

K H Kim↗

Three-dimensional super line-localization in low signal-to-noise microscope images via prior-apprised unsupervised learning (PAUL)

Biological processes such as processive enzyme turnover and intracellular cargo tracking involve the dynamic motion of a small "article" along a curvilinear biopolymer track. To understand these processes that occur across multiple length and time scales, one must acquire both the trajectory of the particle and the position of the track along which it moves, possibly by combining high-resolution single-particle tracking with conventional microscopy. Yet, usually there is a significant resolution mismatch between these modalities: while the tracked particle is localized with a precision of 10 nm, the image of the surroundings is limited by optical difraction, with 200 nm lateral and 500 nm axial resolutions. Compared to the particle's trajectory, the surrounding curvilinear structure appears as a blurred and noisy image. This disparity in the spatial resolutions of the particle trajectory and the surrounding curvilinear structure image makes data reconstruction, as well as interpretation, particularly challenging. Analysis is further complicated when the curvilinear structures are oriented arbitrarily in 3D space. Here, we present a prior-apprised unsupervised learning (PAUL) approach to extract information from 3D images where the underlying features resemble a curved line such as a filament or microtubule. This three-stage framework starts with a Hessian-based feature enhancement, which is followed by feature registration, where local line segments are detected on repetitively sampled subimage tiles. In the final stage, statistical learning, segments are clustered based on their geometric relationships. Principal curves are then approximated from each segment group via statistical tools including principal component analysis, bootstrap and kernel transformation. This procedure is characterized on simulated images, where sub-voxel medium deviations from true curves have been achieved. The 3D PAUL approach has also been implemented for successful line localization in experimental 3D images of gold nanowires obtained using a multifocal microscope. Lastly, this work not only bridges the resolution gap between two microscopy modalities, but also allows us to conduct 3D super line-localization imaging experiments, without using super-resolution techniques.

42 ENGINEERING↗

Evolution of International Space Station GN&C System Across ISS Assembly Stages

The Guidance Navigation and Control (GN&C) system for the International Space Station is initially implemented by the Functional Cargo Block (FGB) which was built by the Khrunichev Space Center under direct contract to Boeing. This element (Stage 1A/R) was launched on 20 November 1998 and is currently operating on-orbit. The components and capabilities of the FGB Motion Control System (MCS) are described. The next ISS element, which has GN&C functionality will be the Service Module (SM) built by Rocket Space Corporation-Energia. This module is scheduled for launch (Stage 1R) in early 2000. Following activation of the SM GN&C system, the FGB MCS is deactivated and no longer used. The components and capabilities of the SM GN&C system are described. When a Progress vehicle is attached to the ISS it can be used for reboost operations, based on commands provided by the Mission Control Center-Moscow. When a data connection is implemented between the SM and the Progress, the SM can command the Progress thrusters for attitude control and reboosts. On Stage 5A, the U.S. GN&C system will become activated when the U.S. Laboratory is de loyed and installed (launch schedule is currently TBD). The U.S. GN&C system provides non-propulsive control capabilities to support micro-gravity operations and minimize the use of propellant for attitude control, and an independent capability for determining the ISS state vector, attitude, attitude rate. and time.. The components and capabilities of the U.S. GN&C system are described and the interactions between the U.S. and Russian Segment GN&C systems are also described.

Lee, Roscoe↗

Stroboscopic Interferometer for Measuring Mirror Vibrations

Stroboscopic interferometry is a technique for measuring the modes of vibration of mirrors that are lightweight and, therefore, unavoidably flexible. The technique was conceived especially for modal characterization of lightweight focusing mirror segments to be deployed in outer space; however, the technique can be applied to lightweight mirrors designed for use on Earth as well as the modal investigation of other optical and mechanical structures. To determine the modal structure of vibration of a mirror, it is necessary to excite the mirror by applying a force that varies periodically with time at a controllable frequency. The excitation can utilize sinusoidal, square, triangular, or even asynchronous waveforms. Because vibrational modes occur at specific resonant frequencies, it is necessary to perform synchronous measurements and sweep the frequency to locate the significant resonant modes. For a given mode it is possible to step the phase of data acquisition in order to capture the modal behavior over a single cycle of the resonant frequency. In order to measure interferometrically the vibrational response of the mirror at a given frequency, an interferometer must be suitably aligned with the mirror and adjustably phase-locked with the excitation signal. As in conventional stroboscopic photography, the basic idea in stroboscopic interferometry is to capture an image of the shape of a moving object (in this case, the vibrating mirror) at a specified instant of time in the vibration cycle. Adjusting the phase difference over a full cycle causes the interference fringes to vary over the full range of motion for the mode at the excitation frequency. The interference-fringe pattern is recorded as a function of the phase difference, and, from the resulting data, the surface shape of the mirror for the given mode is extracted. In addition to the interferometer and the mirror to be tested, the equipment needed for stroboscopic interferometry includes an arbitrary-function generator (that is, a signal generator), an oscilloscope, a trigger filter, and an advanced charge-coupled-device (CCD) camera. The optical components are positioned to form a pupil image of the mirror under test on the CCD chip, so that the interference pattern representative of the instantaneous mirror shape is imaged on the CCD chip.

Stahl, H. Philip↗