Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear data analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

LET Spectrum Measurements In CR-39 PNTD With AFM

Energetic protons, neutrons, and heavy ions undergoing collisions with target nuclei of varying Z can produce residual heavy recoil fragments via intra-nuclear cascade/evaporation reactions. The particles produced in these non-elastic collisions generally have such extremely short range ({approx}<10 {mu}m) that they cannot be directly observed by conventional detection methods including CR-39 plastic nuclear track detector (PNTD) that has been chemically etched for analysis by standard visible light microscopy. However, high-LET recoil fragments having range on the order of several cell diameters can be produced in tissue during radiotherapy using proton and carbon beams. We have developed a method to analyze short-range, high-LET tracks in CR-39 plastic nuclear track detector (PNTD) using short duration chemical etching ({approx}<1 {mu}m) following by automated atomic force microscope (AFM) scanning. The post-scan data processing used in this work was based on semi-automated matrix analysis opposed to traditional grey-scale image analysis. This method takes advantage of the 3-D data obtained via AFM to achieve robust discrimination of nuclear tracks from other features inherently present in the post-etch detector surface. Through automation of AFM scanning, sufficient AFM scan frames were obtained to attain an LET spectrum spanning the LET range from 200-1500 keV/{mu}m. In addition to our experiments, simulations were carried out with the Monte Carlo transport code, FLUKA. To demonstrate this method, CR-39 PNTD was exposed to the proton therapy beam at Loma Linda University Medical Center (LLUMC) at 60 and 230 MeV. Additionally, detectors were exposed to 1 GeV protons at the NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory (BNL). For these exposures CR-39 PNTD, Al and Cu target foils were used between detector layers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ORNL Neutron Cross Section Measurements of 90 Zr

Nuclear criticality modeling and simulations rely on the quality of the existing evaluated nuclear data libraries such as Evaluated Nuclear Data File (ENDF)/B, the Joint Evaluated Fission and Fusion (JEFF) nuclear data library, or the Japanese Evaluated Nuclear Data Library (JENDL). In some cases, the cross-section evaluations of those libraries were found to be deficient in describing criticality benchmarks accurately. More than two decades ago, the US Nuclear Criticality Safety Program (NCSP) established a Nuclear Data (ND) task which encompassed experiments and evaluations. In response to this, the Oak Ridge National Laboratory (ORNL) formed a Nuclear Criticality and Data group which performed ND experiments, data analysis, and evaluations to produce ENDF files for the ND libraries as identified in the NCSP Five-Year Plan. Before being submitted to the ENDF library, files were processed and tested for performance by running benchmark calculations. This procedure was centralized in the ORNL group and is now often referred to as the ND pipeline. NCSP collaborates with the Joint Research Center (JRC) of the European Commission in Geel, Belgium, to perform high-resolution neutron-induced cross section measurements at the Geel Linear Accelerator (GELINA). The objective is to address emerging ND problems in criticality calculations. Difficulties with ND include insufficient neutron energy range, missing covariances, and previously unrecognized inaccuracies with experiments. New neutron total and capture cross sections of 90 Zr in the neutron energy range from 100 eV to several hundred keV were recently performed. These measured data will be used, together with existing high-resolution transmission data from a metallic 90 Zr sample, to improve representation of the cross sections.

97 MATHEMATICS AND COMPUTING↗

Multi-Institutional Experience Using the MammoSite Radiation Therapy System in the Treatment of Early-Stage Breast Cancer: 2-Year Results

Purpose: To present a retrospective multi-institutional experience of patients treated with the MammoSite radiation therapy system (RTS). Methods and Materials: Nine institutions participated in a pooled analysis of data evaluating the clinical experience of the MammoSite RTS for delivering accelerated partial breast irradiation. Between 2000 and 2004, 483 patients were treated with the MammoSite RTS to 34 Gy delivered in 10 fractions. Treatment parameters were analyzed to identify factors affecting outcome. Results: Median follow-up was 24 months (minimum of 1 year). Overall, infection was documented in 9% of patients, but the rate was only 4.8% if the catheter was placed after lumpectomy. Six patients (1.2%) experienced an in-breast failure; four failures occurred remote from the lumpectomy site (elsewhere failure). Cosmetic results were good/excellent in 91% of patients. Treatment parameters identified as significant on univariate analysis were tested in multivariate regression analysis. The closed-cavity placement technique significantly reduced the risk of infection (p = 0.0267). A skin spacing of <6 mm increased the risk of severe acute skin reaction (p 0.0178) and telangiectasia (p = 0.0280). The use of prophylactic antibiotics reduced the risk of severe acute skin reaction (p < 0.0001). The use of multiple dwell positions reduced the risk of severe hyperpigmentation (p 0.0278). Infection was associated with an increased risk of fair or poor overall cosmesis (p = 0.0009). Conclusions: In this series of patients, the MammoSite RTS seems to have acceptable toxicity rates and cosmetic outcomes, comparable to those with whole-breast radiotherapy. On the basis of these data, the closed-cavity placement technique, use of prophylactic antibiotics, use of multiple dwell positions, and a minimum skin spacing of 6 mm seem to improve patient outcome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enhanced Component Performance Study: Emergency Diesel Generators 1998–2018

This report presents an enhanced performance evaluation of emergency diesel generators (EDGs) at U.S. commercial nuclear power plants. This report evaluates component performance over time using (1) Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES) data from 1998 through 2018 and (2) maintenance unavailability (UA) performance data from Mitigating Systems Performance Index (MSPI) Basis Document data from 2002 through 2018. The objective is to show estimates of current failure probabilities and rates related to EDGs, trend these data on an annual basis, determine if the current data are consistent with the probability distributions currently recommended for use in NRC probabilistic risk assessments, show how the reliability data differ for different EDG manufacturers and for EDGs with different ratings; and summarize the subcomponents, causes, detection methods, and recovery associated with each EDG failure mode. Engineering analyses were performed with respect to time period and failure mode without regard to the actual number of EDGs at each plant. The factors analyzed are: sub-component, failure cause, detection method, recovery, manufacturer, and EDG rating. A statistically significant increasing trend was identified in the frequency of FTLR demands for emergency power system (EPS) and high pressure core spray (HPCS) EDGs and a statistically significant decreasing trend was identified in the frequency of run > 1H hours for EPS and HPCS EDGs.

99 GENERAL AND MISCELLANEOUS↗

Methods for Processing ENDF/B-VII with NJOY

The NJOY Nuclear Data Processing System is widely used to convert evaluations in the Evaluated Nuclear Data Files (ENDF) format into forms useful for practical applications such as fission and fusion reactor analysis, stockpile stewardship calculations, criticality safety, radiation shielding, nuclear waste management, nuclear medicine procedures, and more. This paper provides a description of the system's capabilities, summary descriptions of the methods used, and information on how to use the code to process the modern evaluated nuclear data files from ENDF/B-VII. It begins with the generation of pointwise libraries, including reaction and resonance reconstruction, Doppler broadening, radiation heating and damage, thermal scattering data, unresolved resonance data, and gas production. It then reviews the production of libraries for the continuous-energy Monte Carlo code MCNP, multigroup neutron, photon, and particle cross sections and matrices, and photon interaction data. The generation of uncertainty information for ENDF data is discussed, including new capabilities for calculating covariances of resonance data, angular distributions, energy distributions, and radioactive nuclide production. NJOY's ability to prepare thermal scattering data evaluations for bound moderators (which was used during the preparation of the ENDF/B-VII library) is described. The strong plotting capabilities of NJOY are summarized. Many examples of black and white and color Postscript plots are included throughout the paper. The capabilities of NJOY to output multigroup data in several different formats to suit various applications is reviewed. Finally, a section is included that summarizes the history of the development of the NJOY system over the last 37 years.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Control rod calibration and reactivity effects at the IPEN/MB-01 reactor

Researches that aim to improve the performance of neutron transport codes and quality of nuclear cross section databases are very important to increase the accuracy of simulations and the quality of the analysis and prediction of phenomena in the nuclear field. In this context, relevant experimental data such as reactivity worth measurements are needed. Control rods may be made of several neutron absorbing materials that are used to adjust the reactivity of the core. For the reactor operation, these experimental data are also extremely important: with them it is possible to estimate the reactivity worth by the movement of the control rod, understand the reactor response at each rod position and to operate the reactor safely. This work presents a temperature correction approach for the control rod calibration problem. It is shown the control rod calibration data of the IPEN/MB-01 reactor, the integral and differential reactivity curves and a theoretical analysis, performed by the MCNP-5 reactor physics code, developed and maintained by Los Alamos National Laboratory, using the ENDF/B-VII.0 nuclear data library.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Review of multi-faceted morphologic signatures of actinide process materials for nuclear forensic science

Particle morphology is an emerging signature that has the potential to identify the processing history of unknown nuclear materials. Using readily available scanning electron microscopes (SEM), the morphology of nearly any solid material can be measured within hours. Coupled with robust image analysis and classification methods, the morphological features can be quantified and support identification of the processing history of unknown nuclear materials. The viability of this signature depends on developing databases of morphological features, coupled with a rapid data analysis and accurate classification process. With developed reference methods, datasets, and throughputs, morphological analysis can be applied within days to (i) interdicted bulk nuclear materials (gram to kilogram quantities), and (ii) trace amounts of nuclear materials detected on swipes or environmental samples. In conclusion, this review aims to develop validated and verified analytical strategies for morphological analysis relevant to nuclear forensics.

36 MATERIALS SCIENCE↗

Reirradiation for Head-and-Neck Cancer: Delicate Balance Between Effectiveness and Toxicity

Purpose: To analyze the effectiveness and toxicity of reirradiation (re-RT) for head-and-neck cancer. Methods and Materials: A retrospective data analysis was performed of 58 patients who underwent re-RT with curative intent. Re-RT was given as definitive treatment in 53% of patients, whereas salvage surgery preceded reirradiation in 47%. The median cumulative RT dose was 119 Gy (range, 76-140). Concurrent chemotherapy was administered with re-RT (CRT) in 57% of patients. Event-free survival was defined as survival without recurrence and without serious toxicity ({>=}Grade 3). Results: Median follow-up was 57 months (range, 9-140). Locoregional (LR) control was 50% at 2 and 5 years. The 2-year and 5-year overall survival (OS) was 42% and 34%. The following factors were associated with improved OS: postoperative re-RT (vs. primary re-RT), treatment with RT only (vs. CRT) and interval >3 years between previous RT and re-RT. For patients treated with postoperative re-RT and definitive re-RT, the 5-year OS was 49% and 20%, respectively. Patients treated with CRT had a 5-year OS of 13%. Serious (late) toxicity {>=}Grade 3 was observed in 20 of 47 evaluable patients (43%). Three cases of treatment-related death were recorded. The 2- and 5-year serious toxicity-free interval was 59% and 55%, respectively. Associated with increased risk of serious toxicity were CRT and higher re-RT dose. The event-free survival rates at 2 and 5 years were 34% and 31%, respectively. Conclusions: Re-RT in head-and-neck cancer is associated with poor survival rates of 13-20% in patients with inoperable disease treated with primary (chemo-) re-RT. For this subgroup, however, no other curative options are available. Long-term disease control and survival can be achieved in patients who receive re-RT as an adjunct to surgical resection. The rates of serious toxicity after re-RT are high, with an incidence of approximately 45% at 5 years. Approximately 1 in 3 patients survived re-RT without recurrence and severe complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

{sup 1}H NMR-based spectroscopy detects metabolic alterations in serum of patients with early-stage ulcerative colitis

Highlights: •Twenty ulcerative colitis patients and nineteen healthy controls were enrolled. •Increased 3-hydroxybutyrate, glucose, phenylalanine, and decreased lipid were found. •We report early stage diagnosis of ulcerative colitis using NMR-based metabolomics. -- Abstract: Ulcerative colitis (UC) has seriously impaired the health of citizens. Accurate diagnosis of UC at an early stage is crucial to improve the efficiency of treatment and prognosis. In this study, proton nuclear magnetic resonance ({sup 1}H NMR)-based metabolomic analysis was performed on serum samples collected from active UC patients (n = 20) and healthy controls (n = 19), respectively. The obtained spectral profiles were subjected to multivariate data analysis. Our results showed that consistent metabolic alterations were present between the two groups. Compared to healthy controls, UC patients displayed increased 3-hydroxybutyrate, β-glucose, α-glucose, and phenylalanine, but decreased lipid in serum. These findings highlight the possibilities of NMR-based metabolomics as a non-invasive diagnostic tool for UC.

60 APPLIED LIFE SCIENCES↗

Using the JCC-71 neutron coincidence collar as a benchmark for detector characterization with PTR-32 list mode data acquisition

Augmenting or interchanging current international safeguards shift registerbased data acquisition systems with list mode data acquisition systems gives nondestructive assay (NDA) systems greater versatility. Neutron list mode data analysis offers comparable analytical results to the more widely used shift register analysis in nuclear material quantification applications and offers several diagnostic tools that are specifically beneficial to in-laboratory characterization and calibration measurements. These benefits include identification of non-ideal behavior, optimization of operational parameters from a single measurement, and an improved understanding of the physics-based behavior of NDA systems for a more precise system representation and more confident assay results. In this work the advantages of using list mode data acquisition for detector characterization are demonstrated experimentally. Two commercial-off-the-shelf International Atomic Energy Agency-supported technologies are used for a typical detector characterization procedure and their performance is compared. Specifically, a 3 He-based Canberra Industries JCC-71 Neutron Coincidence Collar is characterized using the Hungarian Institute of Isotopes’ Pulse Train Recorder-32 (PTR-32) list mode data acquisition system, and the results are compared to those obtained using the standard Canberra Industries JSR-15 model shift register. The quantitative results from the two systems are in agreement, which demonstrates that the PTR-32 is a technically viable alternative to conventional shift register electronics for this task. A suitable procedure for full instrument characterization is described, and the added benefits of list mode for characterization and data collection are discussed. Furthermore, this is an important step toward establishing a procedure for the routine use of list mode data acquisition and analysis for neutron NDA system characterization in safeguards field applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear Energy Return on Energy Investment

This report provides a methodology and requisite data to assess the potential Energy Return on (Energy) Investment (EROI) for nuclear fuel cycle alternatives, and applies that methodology to an example “once-through” fuel cycle using low enrichment uranium (LEU) in conventional light water cooled reactors (LWRs). Within the DOE Office of Nuclear Energy Science and Technology - Fuel Cycle Technologies program, the Fuel Cycle Options Campaign “performs integrating analyses of nuclear energy and fuel cycle systems to inform fuel cycle R&D, programmatic decisions, strategy formulation, and policy development”. Campaign objectives include development of relevant fuel cycle metrics, and development of tools and associated data for analysis of fuel cycle systems. This study represents an extension of a prior evaluation of EROI as a metric for fuel cycle facilities, processes and technologies. That prior study [Simon 2011] addressed the energy return on the addition of fuel recycle to an existing nuclear energy system. Limited to just the addition of fuel recycle, that study did not include all the energy investments required to create, operate and decommission the underlying nuclear fuel cycle, such as uranium mining, fuel fabrication, reactor construction, and used fuel disposition. This extension of the prior work adds these remaining pieces of the fuel cycle to provide a basic evaluation framework and initial data to enable evaluation of EROI for nuclear energy in general. It is intended as a basis for evaluation of alternative fuel cycle options in the future with the addition of pertinent details for other fuel cycle scenarios. In the prior work, a spreadsheet tool was constructed for the specific purpose of this energy input/output analysis of nuclear fuel cycle facilities. This tool allows the user to enter the parameters of the nuclear fuel cycle and assumptions about energy use in reprocessing. In the current analysis, energy consumption for an entire nuclear energy enterprise is considered, including facility construction, materials, facility operation, and decommissioning. The analysis tool has been extended to include the entire fuel cycle for a representative scenario of a once-through LWR nuclear energy system. Energy content data have been developed for an initial representation. In many cases where there is a valid range of plausible energy content, the range is discussed and a representative value selected for demonstration of the evaluation methodology. In this analysis, energy produced is the energy output of power reactors within the fuel cycle. The spreadsheet calculates both Primary EROI and Final EROI for the fuel cycle entered. The EROI is the ratio of the output energy divided by the consumed energy. The intent for this study was to develop the methodology and analysis tool for a complete fuel cycle. It is not the intent of the study to fully explore the wide range of potential energy intensities, or to reconcile the disparate values found in the literature. Representative numbers were used in this demonstration. The methodology and tool do provide a framework for future exploration of the key energy intensity values and for conducting sensitivity studies on specific values, either to assess improved understanding of the values, or to explore the potential for alternative technologies to impact EROI. The Primary and Final Energy EROI values calculated for the representative scenario were ~ 52 and 24, respectively.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterization of cation environments in polycrystalline forsterite by Mg-25 MAS, MQMAS, and QCPMG NMR

Forsterite (Mg2SiO4) is a silicate mineral frequently studied in the Earth sciences as it has a simple crystal structure and fast dissolution kinetics (elemental release rates under typical conditions on the order of 10-7 mol/m2/s1). During the dissolution process, spectroscopic techniques are often utilized to augment solution chemical analysis and to provide data for determining reaction mechanisms. Nuclear magnetic resonance (NMR) is able to interrogate the local bonding arrangement and coordination of a particular nuclide to obtain in structural information. Although previous NMR studies have focused on the silicon and oxygen environments in forsterite, studies focusing on the two nonequivalent magnesium environments in forsterite are limited to a few single-crystal studies. In this study, we present the results of 25Mg MAS, MQMAS, and static QCMG experiments performed on a powdered sample of pure synthetic forsterite. We also present spectral fits obtained from simulation software packages, which directly provide quadrupolar parameters for 25Mg nuclei occupying each of the two nonequivalent magnesium sites in the forsterite structure. These results are compared to calculations of the electric field gradient tenor conducted in previous ab initio studies to make definitive assignments correlating each peak to their respective magnesium site in the forsterite structure. Although previous NMR investigations of forsterite have focused on single-crystal samples, we have focused on powdered forsterite as the increased surface area of powdered samples makes them more amenable to laboratory-scale dissolution studies and, ultimately, the products from chemical weathering may be monitored an quantified.

36 MATERIALS SCIENCE↗

The Relationship Between Dose Rate and Decay Heat for Spent Nuclear Fuel Casks

Decay heat and dose rate are two important limits used for determining the allowable contents of spent fuel (SNF) in dry storage systems and transportation packages. While the decay heat limit is used to maintain fuel cladding integrity and ensure retrievability, dose rates are used to demonstrate compliance with regulatory requirements on radiation protection. Because both dose rate and decay heat result from decay of radioisotopes in SNF, this study is an attempt to examine the relationship between dose rate and decay heat for a given cask design. Dose rates were evaluated for 198 cask configurations, that include various SNF system designs (e.g., storage, transfer, transport), SNF characteristics (e.g., fuel types, burnup, cooling time), and loading maps (e.g., uniform loading, zone loading), while a constant decay heat was maintained. The decay heat was calculated using US Nuclear Regulatory Commission (NRC) Regulatory Guide (RG) 3.54, Revision 2, and verified using ORIGEN sequence within SCALE code system. The ORIGEN outputs were used as source terms in the dose analysis using 198 different configurations. A computer script was developed to calculate the cooling time necessary to achieve a given decay heat for a given enrichment, assembly average burnup, assembly mass, and in-core history using a rootfinder algorithm. Initially the computer script was developed to provide cooling time and burnup calculations directly to the analysis of dose rates and decay heats, so a comparison between Used Nuclear Fuel-Storage Transportation and Disposal Analysis Resource Data System (UNF-ST&DARDS) results and RG3.54 data was made; results are included in the appendix to this document. However, an iterative approach was used to compute cooling time, and its accuracy did not depend on the results of the RG3.54r2 algorithm, although the algorithm was still used. The results of the evaluation presented herein clearly demonstrate that a given decay heat does not correspond to a unique dose rate for a variety of cask and package designs. There is no clear pattern to develop a correlation between decay heat and the source terms. Depending on burnup, enrichment, cask type, and loading pattern, dose rates varied for the exact same decay heat—in some cases by 400% for a given cask. For cases in which decay heat was held constant through selection of the appropriate cooling time, dose rates would decrease with increasing burnup, and in other cases, dose rates would increase. The large variation in dose rates for a constant decay heat indicates that casks loaded based on decay heat—that is allowing any burnup, cooling time, and enrichment combinations that yield the qualified decay heat limit(s) —cannot ensure that an Independent Spent Fuel Storage Installation or a spent fuel transportation package will meet the regulatory limits set forth by the respective regulations, i.e., 10 CFR 72 or 10 CFR 71.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

IMPROVED SEARCH OF PRINCIPAL COMPONENT ANALYSIS DATABASES FOR SPECTRO-POLARIMETRIC INVERSION

We describe a simple technique for the acceleration of spectro-polarimetric inversions based on principal component analysis (PCA) of Stokes profiles. This technique involves the indexing of the database models based on the sign of the projections (PCA coefficients) of the first few relevant orders of principal components of the four Stokes parameters. In this way, each model in the database can be attributed a distinctive binary number of 2{sup 4n} bits, where n is the number of PCA orders used for the indexing. Each of these binary numbers (indices) identifies a group of ''compatible'' models for the inversion of a given set of observed Stokes profiles sharing the same index. The complete set of the binary numbers so constructed evidently determines a partition of the database. The search of the database for the PCA inversion of spectro-polarimetric data can profit greatly from this indexing. In practical cases it becomes possible to approach the ideal acceleration factor of 2{sup 4n} as compared to the systematic search of a non-indexed database for a traditional PCA inversion. This indexing method relies on the existence of a physical meaning in the sign of the PCA coefficients of a model. For this reason, the presence of model ambiguities and of spectro-polarimetric noise in the observations limits in practice the number n of relevant PCA orders that can be used for the indexing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Uranium and plutonium prompt-fission-neutron energy spectrum (PFNS) from the analysis of NTS NUEX data

The neutron experiment (NUEX) was a common diagnostic on nuclear device tests conducted at the Nevada Test Site (NTS). In these experiments neutrons from a device pass up a collimated line of site, and in the case of a Faraday cup (FC) NUEX, the neutrons pass through a thin CH 2 foil. Some of these neutrons interact with the nuclei in the foil, generating light charged particles (predominately protons) which are collected in a Faraday cup. The time dependence of the Faraday cup current is a measure of the energy spectrum of the neutrons that leak from the device. With good device models and accurate neutron-transport codes, the leakage spectrum can be converted into a prompt fast-neutron-induced fission-neutron energy spectrum (PFNS) from ~1 to 11 MeV. This has been done for two of our events containing a plutonium primary, where the NUEX data were of a particularly high quality, and one event containing a uranium primary. The fission-neutrons in the device were produced by fission events induced by neutrons over a broad range of energies. We have listed the inferred 1.5 MeV n + 239 Pu fission-neutron spectra in Tables 1 to 4 for outgoing neutron energies from 1.5 to ~10.5 MeV, in 1-MeV steps. The uranium device contained a larger high explosive charge. This limited the extraction of the uranium PFNS spectrum to upper neutron energy 9.5 MeV. The listed values represent the fission-neutron emission probability at the quoted outgoing neutron energies and are not the integrals over 1-MeV wide bins. The quoted relative emission probabilities are all relative to the probability of emitting 1.5 MeV neutrons. The presence of the high explosive charge surrounding the fissile material made estimates of the lower energy PFNS (below 1 MeV) problematic. To obtain estimates of the absolute emission probabilities, the low-energy portion of the PFNS was assumed to be as calculated by the Los Alamos (fission) model (LAM). The three NUEX inferred PFNS are labeled Pu-NUEX-1; Pu-NUEX-2; and U-NUEX-1. Pu-NUEX-1 was from an event near the end of US nuclear testing and its data quality was higher than the data associated with the earlier events used to obtain Pu-NUEX-2 and U-NUEX-1.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigating Region-wise Sensitivities for Nuclear Criticality Safety Validation

Whisper is a criticality safety statistical analysis package that uses the sensitivity profile data developed by MCNP6 for a given application and the covariance files for the nuclear data to determine a baseline Upper-Subcritical-Limit (USL) for a given application [1]. Whisper is designed to give a quantifiable basis for the selection of criticality benchmarks used to determine the appropriate calculational margin.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

British Society of Interventional Radiology (BSIR) Inferior Vena Cava (IVC) Filter Registry

Purpose: The British Society of Interventional Radiology (BSIR) Inferior Vena Cava (IVC) Filter Registry was produced to provide an audit of current United Kingdom (UK) practice regarding placement and retrieval of IVC filters to address concerns regarding their safety. Methods: The IVC filter registry is a web-based registry, launched by the BSIR on behalf of its membership in October 2007. This report is based on prospectively collected data from October 2007 to March 2011. This report contains analysis of data on 1,434 IVC filter placements and 400 attempted retrievals performed at 68 UK centers. Data collected included patient demographics, insertion and retrieval data, and patient follow-up. Results: IVC filter use in the majority of patients in the UK follows accepted CIRSE guidelines. Filter placement is usually a low-risk procedure, with a low major complication rate (<0.5 %). Cook Gunther Tulip (560 filters: 39 %) and Celect (359 filters: 25 %) filters constituted the majority of IVC filters inserted, with Bard G2, Recovery filters, Cordis Trapease, and OptEase constituting most of the remainder (445 filters: 31 %). More than 96 % of IVC filters deployed as intended. Operator inexperience (<25 procedure) was significantly associated with complications (p < 0.001). Of the IVC filters initially intended for temporary placement, retrieval was attempted in 78 %. Of these retrieval was technically successful in 83 %. Successful retrieval was significantly reduced for implants left in situ for >9 weeks versus those with a shorter dwell time. New lower limb deep vein thrombosis (DVT) and/or IVC thrombosis was reported in 88 patients following filter placement, there was no significant difference of incidence between filter types. Conclusions: This registry report provides interventional radiologists and clinicians with an improved understanding of the technical aspects of IVC filter placement to help improve practice, and the potential consequences of IVC filter placement so that we are better able to advise patients. There is a significant learning curve associated with IVC filter insertion, and when a filter is placed with the intention of removal, procedures should be in place to avoid the patient being lost to follow-up.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gaussian Process Optimization of Sensitivity-Based Similarity Metrics between New Nuclear Applications and New/Existing Benchmarks [Slides]

This presentation discusses Nuclear Criticality Safety (NCS) and how designing safe, new nuclear criticality experiments requires expert judgement, which could take years of experience. Sensitivity/uncertainty (S/U) analysis can be utilized by less experienced individuals to conservatively estimate uncertainties in important parameters, such as k eff , in newly proposed nuclear experiments. The presentation poses the question of how this analysis can be performed and states that the answer lies in matching new nuclear experiments with existing benchmark experiments using similarity metrics. By increasing the criticality safety of the application in this work, higher mass limits could be used in PF-4 operations. Additionally, the presentation discusses MCNP6.2®, Whisper-1.1, the software that can be used in this analysis. Also discussed is the fact that International Criticality Safety Benchmark Evaluation Project (ICSBEP) benchmarks rarely match new nuclear applications and that there are significant differences in given set of materials and/or geometry. If there are no benchmarks that match the application, the presentation discusses the possibility of creating new benchmarks. In conclusion, this work presents a Gaussian process (GP) optimization scheme that was used to generate new benchmarks with the highest sensitivity-based similarity metrics to user-defined nuclear applications. The Gaussian process optimization successfully designed 3 new experimental benchmarks that were highly correlated to the application of interest and had k eff values near critical. Optimization over c k,i-r has shown that investigating specific isotope reactions for different applications is crucial to designing benchmark experiments. Partial contribution from Pu dominates c k similarity metric. Future work includes testing new stand-alone similarity metrics or new combinations of similarity metrics as the design criterion of this optimization – design criterion is application dependent.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗