Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear data analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Positron annihilation spectroscopy of defects in nuclear and irradiated materials- a review

Positron is the only probe that can detect individual atomic vacancies and small and large vacancy clusters induced by irradiation with remarkable sensitivity, providing information about their size, concentration, and chemical environment. The focus of this review article is to provide guidance to facilitate applications of positron annihilation spectroscopy (PAS) in irradiation-induced defect studies to advance the development of new radiation-tolerant materials. The principle of PAS, its techniques, and data analysis methods are described. PAS studies of defects in nuclear and irradiated materials are reviewed and discussed in depth. Future developments to advance PAS applications in nuclear materials research and studies of materials under extreme environments are presented.

Atomic scale defects↗

Nuclear Mass Visualization and Analysis at nuclearmasses.org

Nuclear masses play an important role in a wide variety of studies, motivating a tremendous surge in new precision mass measurements and global mass models. To handle this information, and to address inadequacies of existing text-based disseminations of nuclear masses, we have built a suite of codes--online at nuclearmasses.org--to manage, visualize, access, manipulate, share, compare, and analyze nuclear mass datasets. The services at this site are described, along with plans for future development.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SAGIPS: A scalable Framework for scidac quantom

As part of the Scientific Discovery through Advanced Computing (SciDAC) program, the Quantum Chromodynamics Nuclear Tomography (QuantOM) project aims to analyze data from Deep Inelastic Scattering (DIS) experiments conducted at Thomas Jefferson National Accelerator Facility and the upcoming Electron Ion Collider. The DIS data analysis is performed on an event level by taking into leveraging nuclear theory models and accounting for experimental conditions. In order to efficiently run multiple analyses under varying conditions, a composable workflow was designed where each section (theory, experiment, objective minimization, etc.) has its own dedicated module. This presentation gives an overview over of the current status of this workflow, highlights present and future challenges, and highlights possible extensions to other projects with similar requirements.

Lersch, Daniel [Thomas Jefferson National Accelera↗

Heavy ion beam probe advances from the first installation of the diagnostic on an RFP (invited)

Heavy ion beam probes have been installed on a variety of toroidal devices, but the first and only application on a reversed field pinch is the diagnostic on the Madison Symmetric Torus. Simultaneous measurements of spatially localized equilibrium potential and fluctuations of density and potential, previously inaccessible in the core of the reversed field pinch (RFP), are now attainable. These measurements reflect the unique strength of the heavy ion beam probe (HIBP) diagnostic. They will help determine the characteristics and evolution of electrostatic fluctuations and their role in transport, and determine the relation of the interior electric field and flows. Many aspects of the RFP present original challenges to HIBP operation and inference of plasma quantities. The magnetic field contributes to a number of the issues: the comparable magnitudes of the toroidal and poloidal fields and edge reversal result in highly three-dimensional beam trajectories; partial generation of the magnetic field by plasma current cause it and hence the beam trajectories to vary with time; and temporal topology and amplitude changes are common. Associated complications include strong ultraviolet radiation and elevated particle losses that can alter functionality of the electrostatic systems and generate noise on the detectors. These complexities have necessitated the development of new operation and data analysis techniques: the implementation of primary and secondary beamlines, adoption of alternative beam steering methods, development of higher precision electrostatic system models, refinement of trajectory calculations and sample volume modeling, establishment of stray particle and noise reduction methods, and formulation of alternative data analysis techniques. These innovative methods and the knowledge gained with this system are likely to translate to future HIBP operation on large scale stellarators and tokamaks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear Concrete Materials Database Phase I Development

The FY 2011 accomplishments in Phase I development of the Nuclear Concrete Materials Database to support the Light Water Reactor Sustainability Program are summarized. The database has been developed using the ORNL materials database infrastructure established for the Gen IV Materials Handbook to achieve cost reduction and development efficiency. In this Phase I development, the database has been successfully designed and constructed to manage documents in the Portable Document Format generated from the Structural Materials Handbook that contains nuclear concrete materials data and related information. The completion of the Phase I database has established a solid foundation for Phase II development, in which a digital database will be designed and constructed to manage nuclear concrete materials data in various digitized formats to facilitate electronic and mathematical processing for analysis, modeling, and design applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Defining Modeling and Analysis Complexity Needs for Remediation - 18425

Many subsurface remedy decisions rely on model predictions or other types of data analyses to support site characterization and remedy selection, design, implementation, performance assessment, and closure. Thus, determining the appropriate level of complexity for modeling and data analysis is important to facilitate subsurface remedy decisions. Multiple factors are important in selecting the appropriate level of complexity in modeling and data analysis. For instance, the type and number of inputs required typically increases with increased complexity of analysis, and the ability to obtain or verify those inputs needs to be considered. The approach needs to establish the relationship between parameters or processes and contaminant transport and the detail of the description needed to meet the analysis objectives. Assessing the modeling complexity associated with the appropriate level of detail can be facilitated by considering complexity of the 1) modeling approach, 2) description of process, and 3) description of heterogeneity. As demonstrated by case studies, using a framework to guide determination of modeling and analysis complexity facilitates selection of the appropriate approach for the site situation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Software enhancements to the IVSEM model of the CTBTO IMS.

Sandia National Laboratories (SNL) developed the Integrated Verification System Evaluation Model (IVSEM) to estimate the performance of the International Monitoring System (IMS) operated by the Comprehensive Nuclear Test Ban Treaty Organization (CTBTO). IVSEM was developed in several phases between 1995 and 2000. The model was developed in FORTRAN with an IDL-based user interface and was compiled for Windows and UNIX operating systems. Continuing interest in this analysis capability, coupled with numerous advances in desktop computer hardware and software since IVSEM was written, enabled significant improvements to IVSEM run-time performance and data analysis capabilities. These improvements were implemented externally without modifying the FORTRAN executables, which had been previously verified. This paper describes the parallelization approach developed to significantly reduce IVSEM run-times and the new test setup and analysis tools developed to facilitate better IVSEM operation.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Study of movement of the western and central belts of Peninsular Malaysia using GPS data analysis

Since the large earthquakes in Sumatera and Nias, there were some tremors incidents at Bukit Tinggi. Therefore, a study on the earth’s crust movement and the effects of the earthquake in Indonesia on the tectonic blocks of Peninsular Malaysia have been carried out using GPS data analysis. GPS data from five MyRTKnet stations within Peninsular Malaysia have been analyzed to monitor the movement of two major tectonic blocks of Peninsular Malaysia which are the western belt represented by the Behrang (BEHR) and UPM Serdang (UPMS) stations and the central belt represented by Bentong (BENT), Jerantut (JRNT) and Temerloh (TLOH) stations. GPS data recorded from 2005 to 2010 were analysed based on horizontal and vertical displacements of the respective stations by using Trimble Business Centre (TBC) software. Based on the results of accumulated displacements of recorded GPS data from January 2006 to December 2013, it shows that the western belt which represented by UPMS has shifted 0.096m towards northwest with changes of ellipsoidal height of +0.030m while the central belt which represented by TLOH has shifted 0.080m towards northwest with changes of ellipsoidal height of −0.015m. Meanwhile, BENT station which is located on the Bentong-Raub suture zone turns to its original position as well as JRNT station. However, BEHR station which are located in western belt do not show any movements. All of these movements may be due to the influence of reactive faults in the stations area stimulated by several large earthquakes that occurred in 2005 to 2010. Study on using the GPS data analysis and combine with integrated geophysical methods are necessary to understand in detail about the tectonic evolution of Peninsular Malaysia.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Process Monitoring for Nuclear Safeguards

Process Monitoring has long been used to evaluate industrial processes and operating conditions in nuclear and non-nuclear facilities. In nuclear applications there is a recognized need to demonstrate the safeguards benefits from using advanced process monitoring on spent fuel reprocessing technologies and associated facilities, as a complement to nuclear materials accounting. This can be accomplished by: defining credible diversion pathway scenarios as a sample problem; using advanced sensor and data analysis techniques to illustrate detection capabilities; and formulating 'event detection' methodologies as a means to quantify performance of the safeguards system. Over the past 30 years there have been rapid advances and improvement in the technology associated with monitoring and control of industrial processes. In the context of bulk handling facilities that process nuclear materials, modern technology can provide more timely information on the location and movement of nuclear material to help develop more effective safeguards. For international safeguards, inspection means verification of material balance data as reported by the operator through the State to the international inspectorate agency. This verification recognizes that the State may be in collusion with the operator to hide clandestine activities, potentially during abnormal process conditions with falsification of data to mask the removal. Records provided may show material is accounted for even though a removal occurred. Process monitoring can offer additional fidelity during a wide variety of operating conditions to help verify the declaration or identify possible diversions. The challenge is how to use modern technology for process monitoring and control in a proprietary operating environment subject to safeguards inspectorate or other regulatory oversight. Under the U.S. National Nuclear Security Administration's Next Generation Safeguards Initiative, a range of potential safeguards applications for process monitoring are under conceptual development and evaluation. This paper reports on a study of process monitoring for a sample problem involving spent fuel reprocessing with aqueous reprocessing technologies. This includes modeling the processes in the context of a nuclear material diversion scenario and measuring the associated process chemistry. A systems-centric model is applied using actual and simulated plant data, advanced sensors, anomaly detection methods, statistical analysis and data authentication methods, to help illustrate the benefits of process monitoring applications.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An integrated data analysis tool for improving measurements on the MST RFP

Many plasma diagnostics contain complementary information. For example, the double-foil soft x-ray system (SXR) and the Thomson Scattering diagnostic (TS) on the Madison Symmetric Torus both measure electron temperature. The complementary information from these diagnostics can be combined using a systematic method based on integrated data analysis techniques, leading to more accurate and sensitive results. An integrated data analysis tool based on Bayesian probability theory was able to estimate electron temperatures that are consistent with both the SXR and TS diagnostics and more precise than either. A Markov Chain Monte Carlo analysis to increase the flexibility of the tool was implemented and benchmarked against a grid search method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Role of Adaptive Radiotherapy During Concomitant Chemoradiotherapy for Lung Cancer: Analysis of Data From a Prospective Clinical Trial

Purpose: Respiratory-gated radiotherapy allows for the reduction of the toxicity associated with concomitant chemoradiotherapy, but the smaller fields used could increase the risk of missing the target. A prospective study was performed to evaluate the dosimetric consequences of time-trend changes in patients with lung cancer who were treated with concomitant chemoradiotherapy. Methods and Materials: A total of 24 lung cancer patients eligible for chemoradiotherapy and gated delivery underwent four-dimensional computed tomography (4D-CT) after 15 fractions. This scan was co-registered with the initial planning 4D-CT and a new planning target volume (PTV) was generated on the basis of the tumor visualized after 15 fractions. Coverage of the repeat PTV was evaluated by applying the original plan to the second scan and recalculating the dose. Plan modification was triggered by a 5% reduction in the PTV included within the 95% isodose volume or an unacceptable increase in the critical organ dose. Results: Of the 21 evaluable patients, 15 had an average reduction in the PTV of 8% after 30 Gy. The PTV increased in the remaining 6 patients, but the increase was >20% in only 1 patient. In the latter patient, disease progression was observed, and repeat planning was required. The plans created using the new PTV were acceptable in all the other patients. Conclusion: The role of adaptive radiotherapy appears limited when respiratory-gated radiotherapy is used to reduce the toxicity related to concomitant chemoradiotherapy. The use of more conformal treatment techniques might provide the rationale for repeat imaging as a method to identify patients at risk of dosimetric miss.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of human performance differences between students and operators when using the Rancor Microworld simulator

Here, from within the umbrella of the Simplified Human Error Experimental Program (SHEEP) framework, this paper analyzes human performance differences between professional and student operators when using a simplified simulator (i.e., Rancor Microworld). This paper represents a crucial step in understanding the fidelity of the simplified simulators and student operators within the SHEEP study. This paper explores a randomized factorial experimental design that features two independent variables: participant type and event class. Six human performance measurements are considered in the experiment. The experiment is conducted using 20 professional reactor operators employed at actual nuclear power plants (NPPs), along with 20 trained students. The experimental data are analyzed via statistical analysis methods. Finally, this paper examines the differences in human performance between actual operators and students when using Rancor Microworld.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Patterns of Radiotherapy Practice for Pancreatic Cancer in Japan: Results of the Japanese Radiation Oncology Study Group (JROSG) Survey

Purpose: To determine the patterns of radiotherapy practice for pancreatic cancer in Japan. Methods and Materials: A questionnaire-based national survey of radiotherapy for pancreatic cancer treated between 2000 and 2006 was conducted by the Japanese Radiation Oncology Study Group (JROSG). Detailed information on 870 patients from 34 radiation oncology institutions was accumulated. Results: The median age of all patients was 64 years (range, 36-88), and 80.2% of the patients had good performance status. More than 85% of patients had clinical Stage T3-T4 disease, and 68.9% of patients had unresectable disease at diagnosis. Concerning radiotherapy (RT), 49.8% of patients were treated with radical external beam RT (EBRT) (median dose, 50.4 Gy), 44.4% of patients were treated with intraoperative RT (median dose, 25 Gy) with or without EBRT (median dose, 45 Gy), and 5.9% of patients were treated with postoperative radiotherapy (median dose, 50 Gy). The treatment field consisted of the primary tumor (bed) only in 55.6% of the patients. Computed tomography-based treatment planning and conformal RT was used in 93.1% and 83.1% of the patients treated with EBRT, respectively. Chemotherapy was used for 691 patients (79.4%; before RT for 66 patients; during RT for 531; and after RT for 364). Gemcitabine was the most frequently used drug, followed by 5-fluorouracil. Conclusion: This study describes the general patterns of RT practice for pancreatic cancer in Japan. Most patients had advanced unresectable disease, and radical EBRT, as well as intraoperative RT with or without EBRT, was frequently used. Chemotherapy with gemcitabine was commonly used in conjunction with RT during the survey period.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving light yield measurements for low-yield scintillators

Light power spectra are introduced as a new tool for relative light yield (LY) determinations. Light event spectra have commonly been used for this purpose. Theoretical background supporting this change is provided. It is shown that the derivative of a light power spectrum can provide a reliable LY measurement at levels as low as 2% of those for high-yield liquid scintillators. In this work, applications to light evolution in the PPO+LAB system and to water-based liquid scintillators are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

University of Washington Clinical Neutron Facility: Report on 26 Years of Operation

Particle radiotherapy facilities are highly capital intensive and must operate over decades to recoup the original investment. We describe the successful, long-term operation of a neutron radiotherapy center at the University of Washington, which has been operating continuously since September 1984. To date, 2836 patients have received neutron radiotherapy. The mission of the facility has also evolved to include the production of unique radioisotopes that cannot be made with the low-energy cyclotrons more commonly found in nuclear medicine departments. The facility is also used for neutron damage testing for industrial devices. In this paper, we describe the challenges of operating such a facility over an extended time period, including a planned maintenance and upgrade program serving diverse user groups, and summarize the major clinical results in terms of tumor control and normal tissue toxicity. Over time, the mix of patients being treated has shifted from common tumors such as prostate cancer, lung cancer, and squamous cell tumors of the head and neck to the rarer tumors such as salivary gland tumors and sarcomas due to the results of clinical trials. Current indications for neutron radiotherapy are described and neutron tolerance doses for a range of normal tissues presented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Neutron Time Projection Chamber for Nuclear Security and Verification Applications

Detection of fast neutrons produced by fission is a powerful method for discovering, verifying the presence, or monitoring significant quantities of special nuclear material (SNM) at up to moderate distances. Fast neutrons are relatively rare in the natural background and can be very penetrating, even in situations when the energetic gamma-rays are well shielded. Fast neutrons point in the direction of their source and can thus be considered for use in imaging, a feature desirable for rapid, high-signal-to-noise detection of concealed SNM and for nuclear verification. We describe the development and performance of a prototype neutron time projection chamber (nTPC) and its use for directional neutron detection and high-resolution neutron imaging. The nTPC is based on {approx}0.025 m{sup 3} of a hydrogen-methane mixture and utilizes a readout system with low channel count and is optimized for low event rates. We experimentally demonstrate robust operation, reliable particle identification, event-by-event directional reconstruction over the entire 4{pi} solid angle, and insensitivity to gamma-rays. High-efficiency and high-resolution modes of operation based on single and double neutron scatters, respectively, have also been demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗