Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHASE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

The 2nd phase of the LEANDRE program: Water-vapor DIAL measurement

As a follow-on of the backscattered lidar, a differential absorption lidar (LEANDRE 2) is now being developed as part of the LEANDRE program for airborne meteorological studies. The primary measurement objective of LEANDRE 2 is water vapor. Pressure and temperature measurements are aimed at a second stage. The goals are to obtain a horizontal resolution of a few hundred meters for a vertical resolution of less than a hundred meters, with an absolute accuracy of 10 percent for humidity measurement. As compatibility is an important feature between the 2 first phases of LEANDRE, most of the LEANDRE 1 sub-system will be used and adapted for LEANDRE 2. For example, detection electronics, central computer, detectors and telescope will be the same. However, important modifications have to be done on the laser source, and spectral control has to be added. Most of the work is thus devoted to those developments, and the status is presented here.

Quaglia, P.↗

Chandra Observations of the Young Cluster NGC 2516

The Chandra observatory was Launched July 23 1999. The first two months of the mission have been spent performing on-orbit calibration. This phase of the mission has included about 60 Ks of observing time on the young cluster NGC 2516. The observations have been made as part of the measurements of the boresight and the plate-scale of the various instruments. These observations will augment planned (deeper) GTO observation of this cluster. Here we present the results of these early observations. As of September 7, in a single ACIS 5'x5' field (one backside chip) examined 26 sources were detected in a single 10 Ks exposure. This represents less than one sixth of the total exposure time and less than one sixth of the total area to be observed during the calibration phase. we will compare the characteristics of those sources detected with Chandra with those detected by ROSAT. Since these observations are being made using all detectors, we will also compare observations among the various detectors.

Wolk, Scott J.↗

The CMS Phase-2 Fast Beam Condition Monitor prototype test with beam

The Fast Beam Condition Monitor (FBCM) is a standalone luminometer for the High Luminosity LHC (HL-LHC) program of the CMS Experiment at CERN. The detector is under development and features a new, radiation-hard, front-end application-specific integrated circuit (ASIC) designed for beam monitoring applications. The achieved timing resolution of a few nanoseconds enables the measurement of both the luminosity and the beam-induced background. The ASIC, called FBCM23, features six channels with adjustable shaping times, enabling in-field fine-tuning. Each ASIC channel outputs a single binary asynchronous signal encoding time-of-arrival and time-over-threshold information. The FBCM is based on silicon-pad sensors, with two sensor designs presently being considered. This paper presents the results of tests of the FBCM detector prototype using both types of silicon sensors with hadron, muon, and electron beams. Irradiated FBCM23 ASICs and silicon-pad sensors were also tested to simulate the expected conditions near the end of the detector's lifetime in the HL-LHC radiation environment. Based on test results, direct bonding between the sensor and ASIC was chosen, and an optimal bias voltage and ASIC threshold for FBCM operation were proposed. The current design of the front-end test board was validated following the beam test and is now being used for the first front-end module, which is expected to be produced in summer 2025. These results represent a major step forward in validating the FBCM concept, first version of the firmware and establishing a reliable design path for the final detector.

Beam-line instrumentation (beam position and profi↗

Comparison of Terra and Aqua MODIS VIS Bands On-Orbit Response

The Moderate Resolution Imaging Spectroradiometer (MODIS) has 36 spectral bands with a total of 490 detectors, covering spectral regions in the visible (VIS), near-infrared (NIR), short-wave infrared (SWIR), mid-wave infrared (MWIR), and long-wave infrared (LWIR). MODIS is a cross-track scanning radiometer which collects data using a rotating scan mirror (both sides) over a wide range of scan angles. The VIS, NIR, and SWIR bands (bands 1-19 and 26) make measurements of daytime surface reflected radiances, thus are referred to as the reflective solar bands (RSB). MODIS was built with a complete set of on-board calibrators, capable of providing radiometric, spatial, and spectral calibration and characterization during its entire mission. The RSB on-orbit calibration is primarily provided using a solar diffuser (SD) and a solar diffuser stability monitor (SDSM). The SD and SDSM calibration system is operated on a regular (weekly to bi-weekly) basis. The spectro-radiometric calibration assembly (SRCA) is another on-hoard calibrator that also provides RSB radiometric calibration support. For this purpose, the SRCA is operated in a radiometric mode on a monthly basis. A complete SRCA radiometric calibration is performed using different lamp configurations, or different radiance levels, to cover the range of RSB gain. Two additional SRCA modes with slightly different configurations are designed and operated for sensor on-orbit spectral and spatial characterization. In addition to its on-hoard calibrators, each MODIS makes monthly lunar observations to monitor RSB radiometric calibration stability. The MODIS lunar observations are made through its space view (SV) port at nearly the same lunar phase angles via spacecraft roll maneuvers. The SD, SRCA, and lunar measurements are made at different scan angles and data samples are collected for all spectral bands and detectors using both sides of the scan minor. Since launch, Terra and Aqua MODIS have operated successfully for more than 8 years and 6 years, respectively. Many SD/SDSM, SRCA, and lunar observations have been made by each instrument and used to derive RSB on-orbit calibration parameters, enabling corrections for sensor response changes and changes of the response versus scan angle (RVS). In general, the RSB calibration parameters are updated regularly into the MODIS Level 1B (LIB) code in support of continuous data processing for all MODIS science data products. This paper provides a brief description of MODIS RSB calibration methodologies and approaches, and summarizes on-orbit changes of their responses (gains), particularly for the VIS spectral bands.

Xiong, Xiaoxiong↗

$\bar{\nu}_\mu$ charged-current $\pi^0$ data release

Data release for the NOvA muon antineutrino charged-current (CC) pi^0 cross section presented in arXiv:2511.05807. The signal for this analysis is defined as muon antineutrino CC interactions in the fiducial volume of the NOvA near detector (a 2.7 m × 2.7 m × 9.0 m region) that produce at least one pi^0 in the final state emerging from the nucleus, within the phase space of muon momentum [0.5, 2.5) GeV/c and muon angle [0, 60) degree, as described in arXiv:2511.05807. The released zip file contains two files: NOvA_NumubarCCPi0_DataRelease.root README.txt The ROOT file includes the cross-section results as well as the statistical and systematic covariance matrices for each variable used in this analysis. The README provides a detailed description of the contents of the data release. Official Flux: The flux used in this analysis is available from the NOvA Public Docs: https://publicdocs.fnal.gov/cgi-bin/ShowDocument?docid=8. File structure --- The ROOT file contains the following TDirectories: pi0p - pi^0 momentum distributions pi0dir - pi^0 angular distributions muonp - muon momentum distributions muondir - muon angular distributions Q2 - reconstructed Q^2 distributions Wmass - reconstructed W_mass distributions Each directory contains three histograms: xsec (TH1D): Cross section result cov_stat (TH2D): Statistical covariance matrix cov_syst (TH2D): Systematic covariance matrix Usage notes: - xsec gives the measured differential cross section w.r.t. the corresponding variable. - cov_stat and cov_syst provide the full covariance matrices. - The bin definitions and kinematic phase spaces follow those used in arXiv:2511.05807. Citation --- If you use these data, please cite: NOvA Collaboration, arXiv:2511.05807.

Wu, Wanwei [Pittsburgh U.] (ORCID:0000000326327215↗

Optimal signal-to-noise in digital phase lock amplifiers

An expression for the optimal signal-to-noise ratio for linear phase lock amplifiers is derived. In its digital form the optimal method can be implemented by real-time signal processing techniques. The case of detector-noise-limited systems is analyzed in detail; it is found that the optimal technique can be used to eliminate effectively the detector's time constant from the set of parameters determining the overall efficiency. This has important implications for optical detection system design. Also reported is an experimental verification of the optimal method, thus establishing its practicality.

Doering, Charles R.↗

The CHARIS IFS for high contrast imaging at Subaru

The Coronagraphic High Angular Resolution Imaging Spectrograph (CHARIS) is an integral field spectrograph (IFS) being built for the Subaru telescope. CHARIS will take spectra of brown dwarfs and hot Jovian planets in the coronagraphic image provided by the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) and AO188 adaptive optics systems. The system is designed to detect objects five orders of magnitude dimmer than their parent star down to an 80 milliarcsecond inner working angle. For characterization, CHARIS has a high-resolution prism providing an average spectral resolution of R82, R69, and R82 in J, H, and K bands respectively. The so-called discovery mode uses a second low-resolution prism with an average spectral resolution of R19 spanning 1.15-2.37 microns (J+H+K bands). This is unique compared to other high contrast IFS designs. It augments low inner working angle performance by reducing the separation at which we can rely on spectral differential imaging. The principal challenge for a high-contrast IFS is quasi-static speckles, which cause undue levels of spectral crosstalk. CHARIS has addressed this through several key design aspects that should constrain crosstalk between adjacent spectral features to be below 1%. Sitting on the Nasmyth platform, the alignment between the lenslet array, prism, and detector will be highly stable, key for the performance of the data pipeline. Nearly every component has arrived and the project is entering its final build phase. Here we review the science case, the resulting design, status of final construction, and lessons learned that are directly applicable to future exoplanet instruments.

Subaru Coronagraphic Extreme Adaptive Optics (SCEx↗

Reconstruction of Six-Dimensional Phase Space

A phase space is a mathematical representation of all possible physical states of a system. Particle beams at Fermilab exist within a six-dimensional (6D) phase space defined by three positional components, (x, y, z) and three momentum components, (px, py, pz). To reconstruct this space implies taking measurement data from detectors and mapping out particle behavior using computational methods. The beam detectors, however, are only able to detect spatial distribution among the events of the beam, therefore being limited to positional data. Also, due to the vast number of events in a particle beam, it is extremely difficult to analyze and differentiate every single one’s behavior. However, with Machine Learning (ML), which can distinguish between patterns and map out particle behavior more efficiently. We first used the particle beam software, G4beamline, to simulate a 10,000-event muon beam, adjusting parameters such as initial momentum magnitude (p¬0) and virtual detector position. Using ten virtual detectors, we analyzed p0 values such that minimum 9,990 events were analyzed by every detector. We then input the data from these beam simulations to a C++ program, that randomly selects 100 events, and creates a 2D histogram based on spatial distribution, detector position, and event intensity. This process is repeated 100 times to create 100 histograms per p0 value. These images were then input to a modified ResNet18 Convolutional Neural Network (CNN) for training, and to predict p0 from some unseen set of histograms. The model was accurate when trained on momentum increments of 5 MeV/c and provided with denser training samples around highly variable test values. These results displayed machine learning being able to accurately predict p0 from being trained on different particle behaviors.

Shirlee, Jermain [Fermilab]↗

Algorithms for coordinate reconstruction in position-sensitive virtual Frisch-grid detectors

Arrays of position-sensitive virtual Frisch-grid (VFG) CdZnTe (CZT) detectors provide a cost-effective solution for integrating large-area arrays for gamma-ray imaging and spectroscopy. These detectors employ high-aspect ratio CZT crystals (bars) with thicknesses up to 50 mm and cross-sections of up to 10 × 10 mm 2 . Despite the long drift distances of charge carriers in such crystals, the detectors have demonstrated excellent performance, achieving energy resolutions better than 1 % full width at half maximum (FWHM) at 662 keV and 3D position resolutions finer than 1 mm. The high spatial resolution is a critical feature of these detectors, as it enables correction of response non-uniformities caused by crystal defects, which remain present even in the highest-quality CZT material. Dislocations and dislocation walls are the primary defects responsible for variations in charge carrier losses as they drift from the interaction points toward the charge-collecting electrodes. The mechanism by which these defects affect carrier transport is generally well understood. Dislocations and sub-grain boundaries act as sinks for carrier-trapping centers, primarily impurities and secondary phases such as tellurium inclusions and precipitates. Here, these regions exhibit significantly higher carrier-trapping rates, leading to variations in the μτ-products. Because the locations of these micron-sized regions are fixed within the detector volume, fluctuations in the total collected charge arise from the random distribution of interaction sites. This results in non-uniform detector responses and degradation of energy resolution. However, by measuring the interaction-site locations with sufficient precision, charge-loss variations can be accurately corrected, allowing recovery of nearly intrinsic energy resolution.

47 OTHER INSTRUMENTATION↗

Detector Apparatus and Method

Transceiver and methods are included that are especially suitable for detecting metallic materials, such as metallic mines, within an environment. The transceiver includes a digital waveform generator used to transmit a signal into the environment and a receiver that produces a digital received signal. A tracking module preferably compares an in-phase and quadrature transmitted signal with an in-phase and quadrature received signal to produce a spectral transfer function of the magnetic transceiver over a selected range of frequencies. The transceiver initially preferably creates a reference transfer function which is then stored in a memory. Subsequently measured transfer functions will vary depending on the presence of metal in the environment which was not in the environment when the reference transfer function was determined. The system may be utilized in the presence of other antennas, metal, and electronics which may comprise a plastic mine detector for detecting plastic mines. Despite the additional antennas and other metallic materials that may be in the environment due to the plastic mine detector, the magnetic transceiver remains highly sensitive to metallic material which may be located in various portions of the environment and which may be detected by sweeping the detector over ground that may contain metals or mines.

Arndt, G. Dickey↗

Latest Results from the ICARUS Experiment at the Short-Baseline Neutrino Program

The ICARUS Collaboration is now entering its fifth year of continuing operations of the 760-ton liquid argon T600 detector. The T600 was overhauled at CERN after operations at the LNGS underground laboratory in Italy and moved to its present location at FNAL - as part of the Short-Baseline Neutrino (SBN) program - where it successfully completed its commissioning phase in June 2022. At FNAL ICARUS collects neutrino interactions from both the Booster Neutrino Beam (BNB) and off-axis from the Main Injector Neutrino beam (NuMI). To date, ICARUS has accumulated approximately 5.2\times 10^{20} protons on target (POT) with the BNB and about 6.2\times 10^{20} POT with NuMI. Within the SBN program ICARUS will search for evidence of short-baseline oscillations, potentially explained by eV-scale sterile neutrinos, jointly with the Short-Baseline Near Detector (SBND). In addition, ICARUS is performing stand-along oscillation searches in disappearance mode and measuring neutrino cross sections on argon with both the BNB and NuMI beams. It is also performing searches for additional Beyond the Standard Model signatures. Preliminary results from the ICARUS experiment, using data from the BNB and NuMI neutrino beams, will be presented.

Hausner, Harry [Fermilab]↗

Latest Results from the ICARUS Experiment at the SBN Program

The ICARUS Collaboration is now entering its fifth year of continuing operations of the 760-ton liquid argon T600 detector. The T600 was overhauled at CERN after operations at the LNGS underground laboratory in Italy and moved to its present location at FNAL - as part of the Short-Baseline Neutrino (SBN) program - where it successfully completed its commissioning phase in June 2022. At FNAL ICARUS collects neutrino interactions from both the Booster Neutrino Beam (BNB) and off-axis from the Main Injector Neutrino beam (NuMI). To date, ICARUS has accumulated approximately $7.5\cdot 10^20$ protons on target (POT) with the BNB and about $6.2\cdot 10^20$ POT with NuMI. Within the SBN program ICARUS will search for evidence of short-baseline oscillations, potentially explained by eV-scale sterile neutrinos, jointly with the Short-Baseline Near Detector (SBND). In addition, ICARUS is performing stand-along oscillation searches in disappearance mode and measuring neutrino cross sections on argon with both the BNB and NuMI beams. It is also performing searches for additional Beyond the Standard Model signatures. Preliminary results from the ICARUS experiment, using data from the BNB and NuMI neutrino beams, will be presented.

Ricci, Alessandro Maria [U. Pisa (main); INFN, Pis↗

Evidence for inhomogeneous thermal sources of two similar solar spike event of 1978, May 5 and December 4

Two short duration single spike events of 1978 May 5 and December 4 exhibit similar time profiles in the microwave and hard X-ray ranges, indicating emission from compact sources. Microwave spectral observations exhibit inhomogeneities present in the source parameters. The existence of fine time structures in the microwave time profiles at 10.4 GHz from Berne are interpreted as a signature of the dynamics of a disturbance travelling through the souce at the ion-sound speed. Stereoscopic observations with the hard X-ray detector on the solar orbiter, Helios-2, and the Berne microwave antennae do not indicate any time lag or differences in the time profiles during the impulsive phase. This is taken as evidence for the absence of directionality of emission making beam models unlikely for short duration single spike events.

Wiehl, H. J.↗

Evidence for inhomogeneous thermal sources of two similar solar spike events of 1978 May 5 and December 4

Two short duration single spike solar events of 1978 May 5 and December 4 exhibit similar time profiles in the microwave and hard X-ray ranges, indicating emission from compact sources. Microwave spectral observations exhibit inhomogeneities present in the source parameters. The existence of fine time structures in the microwave time profiles at 10.4 GHz from Berne are interpreted as a signature of the dynamics of a disturbance traveling through the source at the ion-sound speed. Stereoscopic observations with the hard X-ray detector on the solar orbiter, Helios-2, and the Berne microwave antenna do not indicate any time lag or differences in the time profiles during the impulsive phase. This is taken as evidence for the absence of directionality of emission making beam models unlikely for short duration single spike events. Previously announced in STAR as N83-13047

Desai, U.↗

HgCdTe for NASA EOS missions and detector uniformity benchmarks

Important NASA Earth Observing System (EOS) missions, Atmospheric Infrared Sounder (AIRS) and Moderate Resolution Imaging Spectrometer (MODIS-N), which require detector spectral response in the range of 14 to 17 microns at medium background flux levels and operation in the range of temperatures between 65 to 95 K, will be flown beginning in the next few years. Currently, a prime candidate detector technology for these missions is trapping-mode photoconductive HgCdTe devices. These devices can be tailored to the exact cutoff wavelengths required by those missions, and thus offer the performance advantages of an intrinsic detector which is ideally matched to the mission wavelength. Under the long wavelength-background-temperature conditions of these EOS missions, any detector will at best be thermal generation-recombination noise limited. Photoconductive devices are generally preferred under these circumstances, since at elevated temperatures their performance degrades with n(sub i) while for photovoltaic detectors performance degrades as n sub i(exp 2) n sub i is the intrinsic carrier concentration which is a function of alloy composition and temperature, but not doping. Very high performance trapping-mode photoconductive HgCdTe detectors have been developed which can be reproducibly fabricated. Detectivity (D asterisk) at 80K and 16 micron cutoff wavelength in excess of 10(exp 11) Jones has been measured for these devices. Power dissipation is at least two orders of magnitude less than conventional HgCdTe photoconductors - on the order of 0.12 W/cm(exp 2) compared with 12 W/cm(exp 2). EOS missions define thermal noise limited conditions for the long wavelength operating bands. Trapping-mode photoconductive HgCdTe detectors are linear under such conditions and responsivity is independent of background flux. At lower temperatures or high flux conditions in which background flux limits detector performance, trapping-mode detectors have a responsivity which varies with background flux. Internal calibration must be provided for radiometric measurements under the latter conditions (not an EOS mission concern). Liquid phase epitaxy is used to grow these HgCdTe device structures. This technique has been shown to give control of the cutoff wavelength on the order of 16 plus or minus 1 micron or less, both from run to run and across wafer dimensions of several centimeters on a side.

Norton, Paul R.↗

Rocket/Radar Sporadic-E Experiment Conducted during the El Coqui 2 Campaign

In order to investigate the complex electrodynamics and neutral-plasma coupling inherent to sporadic-E layers in the earth's mid-latitude ionosphere, a series of rocket/radar experiments were planned as part of the NASA El Coqui H Campaign from Tortuguero Launch Range, Puerto Rico, in March-April, 1998. The rocket experiments consisted of two pairs of "mother-daughter" payloads with limited apogees so that the payloads "hovered" in the sporadic-E region (95-125 km). Each payload pair included vector DC and AC electric field detectors, a highly accurate flux-gate DC magnetometer, an ion mass spectrometer, an ionization gauge, and spaced-electric field receivers to measure the wavelength and phase velocity of the unstable plasma waves. Separate rockets were included to simultaneously carry aloft TMA trails to measure the neutral wind and its velocity shear, believed responsible for the sporadic-E layer formation. In addition to the rocket experiments, incoherent scatter radar measurements of plasma density and drift velocity were gathered almost every night during the 3 week campaign. Continuous VHF backscatter radar operations were carried out from a site near Salinas, Puerto Rico, where 3-m backscatter echoes were observed associated with sporadic-E and other types of low altitude ionospheric layers. Other radars that operated during the campaign included an HF backscatter system near Ponce, Puerto Rico, and a second VHF backscatter radar set up near Aguadila Puerto Rico. On 24 March 1998, one of the instrumented rockets was launched, attaining an apogee of 129 km. The payloads successfully pierced an intense sporadic-E layer observed by both the Arecibo radar and the in-situ density and ion mass spectrometer probes. In-situ DC electric fields revealed very low (about 1-2 mV/m) ambient fields with small amplitude structures of the same order. No high frequency (short scale) waves were observed, consistent with the VHF backscatter observations at the time of the launch. An overview of the observations will be presented.

Pfaff, R.F.↗

HgCdTe Photoconductive Mixers for 2-8 THz

Heterodyne spectroscopy has been taken to wavelengths as short as 63 micrometers with Schottky-diode mixers. Schottkys, however, are relatively insensitive compared to superconducting mixers such as the hot-electron microbolometer (HEB), which has an effective quantum efficiency of 3% at 120 micrometers (2.5 THz). Although HEB sensitivities are bound to improve, there will always be losses associated with antenna coupling of radiation into sub-micron size devices. Another approach to far infrared (FIR) mixer design is to use a photoconductive device which can be made much larger than a wavelength, and thus act as its own antenna. For example, HgCdTe photodiodes have been used as mixers in the lambda = 10 micrometers band for over 25 years, with sensitivities now only a factor of 2 from the quantum-noise-limit. HgCdTe can also be applied at FIR wavelengths, but surprisingly little work has been done to date. The exception is the pioneering work of Spears and Kostiuk and Spears, who developed HgCdTe photomixers for the 20-120 micrometer region. The spectral versatility of the HgCdTe alloy is well recognized for wavelengths as long as 8-20 micrometers. What is not so recognized, however, is that theoretically there is no long wavelength limit for appropriately composited HgCdTe. Although Spears successfully demonstrated a photoconductive response from HgCdTe at 120 micrometers, this initial effort was apparently never followed up, in part because of the difficulty of controlling the HgCdTe alloy composition with liquid-phase-epitaxy (LPE) techniques. With the availability of precise molecular-beam-epitaxy (MBE) since the early 1990's, it is now appropriate to reconsider HgCdTe for detector applications longward of lambda = 20 micrometers. We recently initiated an effort to fabricate detectors and mixers using II-VI materials for FIR wavelengths. Of particular interest are device structures called superlattices, which offer a number of advantages for high sensitivity direct detectors and very long wavelength heterodyne mixers.

Betz, A. L.↗