Search NASA⌕ Search

SEARCH · Search NASA

Results for “PROSTATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Intensity-Modulated Radiotherapy of Pelvic Lymph Nodes in Locally Advanced Prostate Cancer: Planning Procedures and Early Experiences

Purpose: We present planning and early clinical outcomes of a study of intensity-modulated radiotherapy (IMRT) for locally advanced prostate cancer. Methods and Materials: A total of 43 patients initially treated with an IMRT plan delivering 50 Gy to the prostate, seminal vesicles, and pelvic lymph nodes, followed by a conformal radiotherapy (CRT) plan delivering 20 Gy to the prostate and seminal vesicles, were studied. Dose-volume histogram (DVH) data for the added plans were compared with dose-volume histogram data for the sum of two CRT plans for 15 cases. Gastrointestinal (GI) and genitourinary (GU) toxicity, based on the Radiation Therapy Oncology Group scoring system, was recorded weekly throughout treatment as well as 3 to 18 months after treatment and are presented. Results: Treatment with IMRT both reduced normal tissue doses and increased the minimum target doses. Intestine volumes receiving more than 40 and 50 Gy were significantly reduced (e.g., at 50 Gy, from 81 to 19 cm{sup 3}; p = 0.026), as were bladder volumes above 40, 50, and 60 Gy, rectum volumes above 30, 50, and 60 Gy, and hip joint muscle volumes above 20, 30, and 40 Gy. During treatment, Grade 2 GI toxicity was reported by 12 of 43 patients (28%), and Grade 2 to 4 GU toxicity was also observed among 12 patients (28%). With 6 to 18 months of follow-up, 2 patients (5%) experienced Grade 2 GI effects and 7 patients (16%) experienced Grade 2 GU effects. Conclusions: Use of IMRT for pelvic irradiation in prostate cancer reduces normal tissue doses, improves target coverage, and has a promising toxicity profile.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel MRI Marker for Prostate Brachytherapy

Purpose: Magnetic resonance imaging (MRI) is the optimal imaging modality for the prostate and surrounding critical organ structures. However, on MRI, the titanium radioactive seeds used for brachytherapy appear as black holes (negative contrast) and cannot be accurately localized. We sought to develop an encapsulated contrast agent marker (ECAM) with high-signal intensity on MRI to permit accurate localization of radioactive seeds with MRI during and after prostate brachytherapy. Methods and Materials: We investigated several agents with paramagnetic and superparamagnetic properties. The agents were injected into titanium, acrylic, and glass seeds, which were linked together in various combinations and imaged with MRI. The agent with the greatest T1-weighted signal was tested further in a canine prostate and agarose phantom. Studies were performed on a 1.5-T clinical MRI scanner. Results: The cobalt-chloride complex contrast (C4) agent with stoichiometry (CoCl{sub 2}){sub 0.8}(C{sub 2}H{sub 5}NO{sub 2}){sub 0.2} had the greatest T1-weighted signal (positive contrast) with a relaxivity ratio >1 (r{sub 2}/r{sub 1} = 1.21 {+-} 0.29). Acrylic-titanium and glass-titanium seed strands were clearly visualized with the encapsulated contrast agent marker. Conclusion: We have developed a novel ECAM that permits positive identification of the radioactive seeds used for prostate brachytherapy on MRI. Preclinical in vitro phantom studies and in vivo canine studies are needed to further optimize MRI sequencing techniques to facilitate MRI-based dosimetry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reporting Late Rectal Toxicity in Prostate Cancer Patients Treated With Curative Radiation Treatment

Purpose: Long-term rectal toxicity is a concern for patients with prostate cancer treated with curative radiation. However, comparing results of late toxicity may not be straightforward. This article reviews the complexity of reporting long-term side effects by using data for patients treated in our institution with hypofractionated irradiation. Methods and Materials: Seventy-two patients with localized prostate cancer treated with hypofractionated radiotherapy alone to a dose of 66 Gy in 22 fractions were prospectively assessed for late rectal toxicity according to the Common Toxicity Criteria, Version 3, scoring system. Ninety percent of patients had more than 24 months of follow-up. Results are compared with data published in the literature. Results: We found an actuarial incidence of Grade 2 or higher late rectal toxicity of 27% at 30 months and a crude incidence of Grade 2 or higher late rectal toxicity of 18%. This was mostly severe toxicity documented during follow-up. The incidence of Grade 3 rectal toxicity at the last visit was 3% compared with 13% documented at any time during follow-up. Conclusion: Comparison of late toxicity after radiotherapy in patients with prostate cancer must be undertaken with caution because many factors need to be taken into consideration. Because accurate assessment of late toxicity in the evaluation of long-term outcome after radiotherapy in patients with localized prostate cancer is essential, there is a need to develop by consensus guidelines for assessing and reporting late toxicity in this group of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Update of Dutch Multicenter Dose-Escalation Trial of Radiotherapy for Localized Prostate Cancer

Purpose: To update the analysis of the Dutch dose-escalation trial of radiotherapy for prostate cancer. Patients and Methods: A total of 669 patients with localized prostate cancer were randomly assigned to receive 68 or 78 Gy. The patients were stratified by age, institution, use of neoadjuvant or adjuvant hormonal therapy, and treatment group. The primary endpoint was freedom from failure (FFF), with failure defined as clinical or biochemical failure. Two definitions of biochemical failure were used: the American Society for Therapeutic Radiology and Oncology definition (three consecutive increases in prostate-specific antigen level) and the Phoenix definition (nadir plus 2 {mu}g/L). The secondary endpoints were freedom from clinical failure, overall survival, and genitourinary and gastrointestinal toxicity. Results: After a median follow-up of 70 months, the FFF using the American Society for Therapeutic Radiology and Oncology definition was significantly better in the 78-Gy arm than in the 68-Gy arm (7-year FFF rate, 54% vs. 47%, respectively; p = 0.04). The FFF using the Phoenix definition was also significantly better in the 78-Gy arm than in the 68-Gy arm (7-year FFF rate, 56% vs. 45%, respectively; p = 0.03). However, no differences in freedom from clinical failure or overall survival were observed. The incidence of late Grade 2 or greater genitourinary toxicity was similar in both arms (40% and 41% at 7 years; p = 0.6). However, the cumulative incidence of late Grade 2 or greater gastrointestinal toxicity was increased in the 78-Gy arm compared with the 68-Gy arm (35% vs. 25% at 7 years; p = 0.04). Conclusion: The results of our study have shown a statistically significant improvement in FFF in prostate cancer patients treated with 78 Gy but with a greater rate of late gastrointestinal toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

What CTV-to-PTV Margins Should Be Applied for Prostate Irradiation? Four-Dimensional Quantitative Assessment Using Model-Based Deformable Image Registration Techniques

Purpose: To quantify adequate anisotropic clinical target volume (CTV)-to-planning target volume (PTV) margins for three different setup strategies used during prostate irradiation: (1) no setup corrections, (2) on-line corrections determined from bony anatomy, and (3) on-line corrections determined from gold markers. Method and Materials: Three radiation oncologists independently delineated the CTV on computed tomography images of 30 prostate cancer patients. Eight repeat scans were acquired to allow simulation of the delivered dose distributions in changing geometry. Different registration approaches were taken to mimic the different setup strategies. A surface model-based deformable image registration system was used to warp the delivered dose distributions back to the dose in the planning computed tomography scan. On the basis of the geometric extent of the underdosed areas, a set of anisotropic margins was derived to ensure a minimal dose to the CTV of 95% for 90% of the patients. Results: Without setup correction, margins of approximately 11 mm for the corpus of the prostate and 15 mm for the seminal vesicles were required. These margins could be reduced to 8 and 13 mm when aligning the patient to the bony anatomy and to 3 and 8 mm aligning the patient to implanted gold markers. A larger margin at the apex was required to account for the significant observer variability and steep dose gradients at this location (11 mm using skin marker registration, 9 mm using bony anatomy registration, and 6 mm using gold marker registration). Conclusions: Novel voxel tracking techniques have enabled us to calculate accumulated dose distributions and design accurate three-dimensional CTV-to-PTV margins for prostate irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Final Report of Multicenter Canadian Phase III Randomized Trial of 3 Versus 8 Months of Neoadjuvant Androgen Deprivation Therapy Before Conventional-Dose Radiotherapy for Clinically Localized Prostate Cancer

Purpose: To evaluate the effect of 3 vs. 8 months of neoadjuvant hormonal therapy before conventional-dose radiotherapy (RT) on disease-free survival for localized prostate cancer. Methods and Materials: Between February 1995 and June 2001, 378 men were randomized to either 3 or 8 months of flutamide and goserelin before 66 Gy RT at four participating centers. The median baseline prostate-specific antigen level was 9.7 ng/mL (range, 1.3-189). Of the 378 men, 26% had low-, 43% intermediate-, and 31% high-risk disease. The two arms were balanced in terms of age, Gleason score, clinical T category, risk group, and presenting prostate-specific antigen level. The median follow-up for living patients was 6.6 years (range, 1.6-10.1). Of the 378 patients, 361 were evaluable, and 290 were still living. Results: The 5-year actuarial freedom from failure rate for the 3- vs. 8-month arms was 72% vs. 75%, respectively (p = 0.18). No difference was found in the failure types between the two arms. The median prostate-specific antigen level at the last follow-up visit for patients without treatment failure was 0.6 ng/mL in the 3-month arm vs. 0.50 ng/mL in the 8-month arm. The disease-free survival rate at 5 years was improved for the high-risk patients in the 8-month arm (71% vs. 42%, p = 0.01). Conclusion: A longer period of NHT before standard-dose RT did not alter the patterns of failure when combined with 66-Gy RT. High-risk patients in the 8-month arm had significant improvement in the 5-year disease-free survival rate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Poor Predictive Value of Intraoperative Real-Time Dosimetry for Prostate Seed Brachytherapy

Purpose: To identify dosimetric parameters predictive of a good prostate seed I{sup 125} quality implant. We analyzed preimplant and postimplant realtime dosimetry in patients treated with intraoperative (IO) inverse planning. Methods and Materials: We analyzed 127 consecutively treated patients with primarily low-risk prostate carcinoma who underwent prostate permanent seed I{sup 125} brachytherapy using an IO planning approach. The implant was done using the three-dimensional transrectal ultrasound (PRE-TRUS)-guided IO interactive inverse preplanning system. The TRUS was repeated in the operating room after the implant procedure was complete (POST-TRUS). The prostate was recontoured and postimplant dosimetry was calculated. Each patient underwent computed tomography scan on Day 28 (CT-D28) to evaluate implant quality. Area under the receiver operating characteristic curves (AUROC) was evaluated for models predictive of a V100 of {>=}90% and a D90 of {>=}140 Gy on the basis of CT-D28 values. Results: On CT-D28, 72.4% of patients had a V100 of {>=}90% and 74.8% had a D90 of {>=}140 Gy. AUROC for a V100 of {>=}90% was 0.665 (p = 0.004) on PRE-TRUS and 0.619 (p = 0.039) on POST-TRUS. AUROC for D90 of {>=}140 Gy was 0.602 (p = 0.086) on PRE-TRUS and 0.614 (p = 0.054) on POST-TRUS. Using PRE-TRUS V100 cutoff of >97% gives sensitivity of 88% and a false-positive rate of 63%. A POST-TRUS D90 cutoff of >170 Gy resulted in a sensitivity of 62% and a false-positive rate of 34%. Conclusions: Because of unacceptably high false-positive rates, IO preimplant and postimplant TRUS-based dosimetry are not accurate tools to predict for postimplant computed tomography-based dosimetry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of Interfraction Prostate Motion Using Megavoltage Cone Beam Computed Tomography

Purpose: Determine the degree of interfraction prostate motion and its components measured by using daily megavoltage (MV) cone beam computed tomography (CBCT) imaging. Methods and Materials: A total of 984 daily MV CBCT images from 24 patients undergoing definitive intensity-modulated radiotherapy for localized prostate cancer were analyzed retrospectively. Pretreatment couch shifts, based on physician registration of MV CBCT to planning CT data sets, were used as a measure of daily interfraction motion. Off-line bony registration was performed to separate bony misalignment from internal organ motion. Interobserver and intraobserver variation studies were performed on 20 MV CBCT images. Results: Mean interfraction prostate motion was 6.7 mm, with the greatest single-axis deviation in the anterior-posterior (AP) direction. The largest positional inaccuracy was accounted for by systematic deviations in bony misalignment, whereas random deviations occurred from bony misalignment and internal prostate motion. In the aggregate, AP motion did not correlate with days elapsed since beginning therapy or on average with rectal size at treatment planning. Interobserver variation was greatest in the AP direction, decreased in experienced observers, and further decreased in intraobserver studies. Mean interfraction motion during the first 6 days of therapy, when used as a subsequent offset, reduced acceptable AP planning target volume margins by 50%. Conclusion: The MV CBCT is a practical direct method of daily localization that shows significant interfraction motion with respect to conventional three-dimensional conformal and intensity-modulated radiotherapy margins, similar to that measured in other modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Biochemical Relapse-Free Survival Between Primary Gleason Score 3 and Primary Gleason Score 4 for Biopsy Gleason Score 7 Prostate Cancer

Purpose: To determine whether the primary grade (PG) of biopsy Gleason score (GS) 7 prostate cancer (CaP) was predictive for biochemical relapse-free survival (bRFS). Most of the present data regarding the PG of GS7 CaP refer to surgical specimens. Our goal was to determine whether the biopsy GS used at the time of medical decision making predicted for the biochemical outcome. Methods and Materials: We reviewed the data from 705 patients with biopsy GS7 CaP, from a prospectively maintained database, who had been treated at our institution between September 1996 and March 2005 with radical prostatectomy (n = 310), external beam radiotherapy (n = 268), or prostate radioactive seed implantation (n = 127). The bRFS rates were estimated using the Kaplan-Meier method. Cox proportional hazards regression analysis was used for univariate and multivariate analyses examining these factors in relation to bRFS: PG of biopsy GS, initial prostate-specific antigen level, clinical T stage, use of androgen deprivation, risk group (high or intermediate), and treatment modality. Results: The 5-year bRFS rate was 78% and 71% (p = 0.0108) for biopsy GS7 PG3 CaP and biopsy GS7 PG4 CaP, respectively. Comparing PG3 and PG4 within treatment modalities, only prostate implantation patients had a significant difference in the 5-year bRFS rate, 88% vs. 76%, respectively (p = 0.0231). On multivariate analysis, the PG of biopsy GS remained an independent predictor of bRFS, with PG3 having better bRFS than PG4 (relative risk, 0.655; 95% confidence interval, 0.472-0.909; p = 0.0113). Conclusion: Biopsy GS7 PG4 CaP carries a worse bRFS than biopsy GS7 PG3 CaP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Dosimetric Parameters and Disease Response After {sup 125}Iodine Transperineal Brachytherapy for Low- and Intermediate-Risk Prostate Cancer

Purpose: To analyze dosimetric outcomes after permanent brachytherapy for men with low-risk and 'low-tier' intermediate-risk prostate cancer and explore the relationship between the traditional dosimetric values, V100 (volume of prostate receiving 100% of the prescribed dose) and D90 (minimum dose to 90% of the prostate), and risk of biochemical failure. Methods and Materials: A total of 1,006 consecutive patients underwent implantation between July 20, 1998, and Oct 23, 2003. Most (58%) had low-risk disease; the remaining 42% comprised a selected low-tier subgroup of intermediate-risk patients. The prescribed minimum peripheral dose (MPD) was 144 Gy. All implants used 0.33 mCi {sup 125}I sources using a preplan technique featuring right-left symmetry and a strong posterior-peripheral dose bias. Sixty-five percent of patients had 6 months of androgen deprivation therapy. Postimplantation dosimetry was calculated using day-28 CT scans. Results: With a median follow-up of 54 months, the actuarial 5-year rate of freedom from biochemical recurrence (bNED) was 95.6% {+-} 1.6%. Median D90 was 105% of MPD, median V100 was 92%, median V150 was 58%, and median V200 was 9%. Dosimetric values were not predictive of biochemical recurrence on univariate or multivariate analysis. Analysis of dosimetric values by implantation number showed statistically significant increases in all values with time (D90, V100, V150, and V200; p < 0.001), but this did not translate into improved bNED. Conclusions: In contrast to some previous studies, dosimetric outcomes did not correlate with biochemical recurrence in the first 1,006 patients treated with {sup 125}I prostate brachytherapy at the British Columbia Cancer Agency. Despite a median D90 of only 105% of MPD, our bNED rates are indistinguishable from series that reported higher D90 values.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sooner or Later? Outcome Analysis of 431 Prostate Cancer Patients Treated With Postoperative or Salvage Radiotherapy

Purpose: To evaluate the outcome of postoperative radiotherapy (PORT) and salvage RT (SART) using a three-dimensional conformal two-dynamic arc (3D-ART) or 3D six-field technique in 431 prostate cancer patients. Methods and Materials: Of the 431 patients, 258 underwent PORT (started <6 months after radical prostatectomy) and 173 underwent SART because of biochemical failure after radical prostatectomy. The median patient age, preoperative prostate-specific antigen level, and Gleason score was 66 years, 9.4 ng/mL, and 7, respectively. The median radiation dose was 70 Gy in 35 fractions for both PORT and SART. The 3D six-field and 3D-ART techniques were used in 25.1% and 74.9% of patients, respectively. Biochemical failure was defined as a post-RT prostate-specific antigen nadir plus 0.1 ng/mL. Results: Acute toxicity included rectal events (PORT, 44.2% and 0.8% Grade 1-2 and Grade 3, respectively; SART, 42.2% and 1.2% Grade 1-2 and Grade 3, respectively) and urinary events (PORT, 51.2% and 2.3% Grade 1-2 and Grade 3-4, respectively; SART, 37.6% and 0% Grade 1-2 and Grade 3, respectively). Late toxicity also included rectal events (PORT, 14.7% and 0.8% Grade 1-2 and Grade 3-4, respectively; SART, 15.0% and 0.6% Grade 1-2 and Grade 3, respectively) and urinary events (PORT, 28.3% and 3.7% Grade 1-2 and Grade 3-4, respectively; SART, 19.3% and 0.6% Grade 1-2 and Grade 3, respectively). After a median follow-up of 48 months, failure-free survival, including biochemical and clinical failure, was significantly longer in the PORT patients (79.8% vs. 60.5%, p < 0.0001). Multivariate analysis showed that a prostate-specific antigen level postoperatively but before RT of {>=}0.2 ng/mL (p < 0.001), Gleason score >6 (p = 0.025) and use of preoperative androgen deprivation (p = 0.002) correlated significantly with shorter failure-free survival. Multivariate analysis showed that PORT and the 3D-ART technique correlated with greater late urinary toxicity. Conclusion: PORT and early referral for SART offer better disease control after radical prostatectomy. The greater urinary toxicity occurring after PORT and 3D-ART requires further investigation to improve the therapeutic index.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Usefulness of Diffusion-Weighted Imaging in the Localization of Prostate Cancer

Purpose: Advances in high-precision radiation therapy techniques for patients with prostate cancer permit selective escalation of the radiation dose delivered to the dominant intraprostatic lesion and improve the therapeutic ratio. We evaluated the value of diffusion-weighted imaging (DWI) for dominant intraprostatic lesion assessment. Methods and Materials: The study population consisted of 23 patients with early prostate cancer. Before undergoing total prostatectomy, they were evaluated by means of magnetic resonance imaging, including DWI. T2-weighted imaging (T2WI) with and without DWI were retrospectively assessed by six independent observers. Imaging findings were compared with pathologic results from whole prostate specimens on a lesion-by-lesion basis. Results: Pathologic study identified 43 lesions in 23 patients. On magnetic resonance imaging, the six observers correctly identified 11-22 of 43 lesions (sensitivity, 26-51%) on T2WI alone and 20-31 (sensitivity, 47-72%) on T2WI plus DWI. Positive predictive values were 42-73% on T2WI alone and 58-80% on T2WI plus DWI. For all observers, detection was higher on combined T2WI and DWI than on T2WI alone. Conclusion: Because the addition of DWI to T2WI improves the detectability of prostate cancer, DWI may offer a promising new approach for radiation therapy planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In Vivo Dosimetry Using a Linear Mosfet-Array Dosimeter to Determine the Urethra Dose In {sup 125}I Permanent Prostate Implants

Purpose: In vivo dosimetry during brachytherapy of the prostate with {sup 125}I seeds is challenging because of the high dose gradients and low photon energies involved. We present the results of a study using metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters to evaluate the dose in the urethra after a permanent prostate implantation procedure. Methods and Materials: Phantom measurements were made to validate the measurement technique, determine the measurement accuracy, and define action levels for clinical measurements. Patient measurements were performed with a MOSFET array in the urinary catheter immediately after the implantation procedure. A CT scan was performed, and dose values, calculated by the treatment planning system, were compared to in vivo dose values measured with MOSFET dosimeters. Results: Corrections for temperature dependence of the MOSFET array response and photon attenuation in the catheter on the in vivo dose values are necessary. The overall uncertainty in the measurement procedure, determined in a simulation experiment, is 8.0% (1 SD). In vivo dose values were obtained for 17 patients. In the high-dose region (> 100 Gy), calculated and measured dose values agreed within 1.7% {+-} 10.7% (1 SD). In the low-dose region outside the prostate (< 100 Gy), larger deviations occurred. Conclusions: MOSFET detectors are suitable for in vivo dosimetry during {sup 125}I brachytherapy of prostate cancer. An action level of {+-} 16% (2 SD) for detection of errors in the implantation procedure is achievable after validation of the detector system and measurement conditions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Effect of Prostate Motion During Helical Tomotherapy

Purpose: To assess the dosimetric consequence of intrafraction prostate motion on helical tomotherapy plans. Methods and Materials: An electromagnetic tracking device was used to measure real-time prostate motion for 515 fractions (16 patients). Motion tracks were used to retrospectively recalculate dose distributions using a four-dimensional calculation engine. The minimum dose (D{sub min}), maximum dose (D{sub max}), and dose to 95% of the volume (D{sub 95%}) were calculated for target volumes and compared with respective values from the treatment plan. The dosimetric effect was evaluated for each fraction. For each patient, the running cumulative effect was assessed throughout the course of treatment. Calculations were repeated assuming a time delay between initial patient setup and start of treatment. Results: Averaged over all fractions, the mean change in target D{sub 95%} was <1% (SD, 3-4%). Reductions in target D{sub 95%} of up to 20% were seen in individual fractions. Changes in prostate D{sub 95%} were similar in frequency and magnitude to D{sub 95%} changes in the planning target volume. The cumulative effect on target D{sub 95%} was approximately 1% (SD, 1%). The average cumulative effect after five fractions was 1% (SD, 1.5%). Conclusions: In general, the dosimetric effect of observed prostate motion on target D{sub 95%}was small. Infrequently severe D{sub 95%} degradations were observed for individual fractions, but their effect on the cumulative dose distribution was quickly reduced with minimal fractionation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Internal Audit of a Comprehensive IMRT Program for Prostate Cancer: A Model for Centers in Developing Countries?

Purpose: With improving regional prosperity, significant capital investments have been made to rapidly expand radiotherapy capacity across Southeast Asia. Yet little has been reported on the implementation of adequate quality assurance (QA) in patient management. The objective of this study is to perform an in-depth QA assessment of our definitive intensity-modulated radiotherapy (IMRT) program for prostate cancer since its inception. Methods and Materials: The department's prostate IMRT program was modeled after that of University of California San Francisco. A departmental protocol consisting of radiotherapy volume/dose and hormone sequencing/duration and a set of 18 dose objectives to the target and critical organs were developed, and all plans were presented at the weekly departmental QA rounds. All patients treated with definitive IMRT for nonmetastatic prostate cancer were retrospectively reviewed. Protocol adherence, dosimetry data, toxicities, and outcomes were evaluated. Results: Since 2005, 76 patients received IMRT: 54 with whole-pelvis and 22 with prostate-only treatment. Of the 1,140 recorded dosimetric end points, 39 (3.3%) did not meet the protocol criteria. At QA rounds, no plans required a revision. Only one major protocol violation was observed. Two and two cases of Grade 3-4 acute and late toxicities, respectively, were observed. Five (8.8%) patients developed proctitis, but only one required argon laser therapy. Conclusions: Our comprehensive, practice-adapted QA measures appeared to ensure that we were able to consistently generate conforming IMRT plans with acceptable toxicities. These measures can be easily integrated into other clinics contemplating on developing such a program.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gleason Pattern 5 Prostate Cancer: Further Stratification of Patients With High-Risk Disease and Implications for Future Randomized Trials

Purpose: To compare prostate-specific antigen (PSA) outcomes in a cohort of men with high-risk prostate cancer based on the presence or absence of any Gleason Grade 5 component (primary, secondary, or tertiary). Methods and Materials: Our study cohort consisted of 312 men with T1c-T3N0M0 prostate cancer with Gleason Scores of 7 with tertiary Grade 5, 8, or 9-10 who underwent radical prostatectomy or external beam radiotherapy with or without androgen suppression therapy. Cox regression multivariable analysis was used to assess whether a difference existed in risk of PSA recurrence in men with Gleason Score of 9-10 compared with those with Gleason Score of 8 and 7 with tertiary Grade 5, adjusting for treatment, age, and known prostate cancer prognostic factors. Results: After a median follow-up of 5.7 years, men with a Gleason Score of 8 had a lower risk of PSA recurrence than those with a Gleason Score of 9-10 (hazard ratio, 0.74; 95% confidence interval, 0.52-1.05; p = 0.09). Conversely, men with a Gleason Score of 7 with tertiary Grade 5 had a similar risk of PSA recurrence compared with men with a Gleason Score of 9-10 (hazard ratio, 1.08; 95% confidence interval, 0.60-1.94; p = 0.81). Median times to PSA failure for men with Gleason Scores of 9-10, 7 with tertiary Grade 5, and 8 were 4.5, 5.0, and 5.4 years, respectively. Conclusions: Our results highlight the importance of further substratification of the high-risk Gleason Score category of 8-10 into 8 vs. 9, 10, and 7 with tertiary Grade 5.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Dose Predicts for Biochemical Control in Intermediate-Risk Prostate Cancer Patients Treated With Low-Dose-Rate Brachytherapy

Purpose: To evaluate the influence of patient- and treatment-related factors on freedom from biochemical failure (FFbF) in patients with intermediate-risk prostate cancer. Methods and Materials: From a prospectively collected database of 2250 men treated at Mount Sinai Hospital from 1990 to 2004 with low-dose-rate brachytherapy for prostate cancer, 558 men with either one or more intermediate-risk features (prostate-specific antigen [PSA] level 10-20 ng/mL, Gleason score 7, or Stage T2b) were identified who had a minimum follow-up of 24 months and postimplant CT-based dosimetric analysis. Biologically effective dose (BED) values were calculated to compare doses from different isotopes and treatment regimens. Patients were treated with brachytherapy with or without hormone therapy and/or external-beam radiotherapy. Patient- and treatment-related factors were analyzed with respect to FFbF. The median follow-up was 60 months (range, 24-167 months). Biochemical failure was defined according to the Phoenix definition. Univariate analyses were used to determine whether any variable was predictive of FFbF. A two-sided p value of <0.05 was considered significant. Results: Overall, the actuarial FFbF at 10 years was 86%. Dose (BED <150 Gy{sub 2} vs. {>=}150 Gy{sub 2}) was the only significant predictor of FFbF (p < 0.001). None of the other variables (PSA, external-beam radiotherapy, Gleason score, treatment type, hormones, stage, and number of risk factors) was found to be a statistically significant predictor of 10-year FFbF. Conclusions: Radiation dose is an important predictor of FFbF in intermediate-risk prostate cancer. Treatment should continue to be individualized according to presenting disease characteristics until results from Radiation Therapy Oncology Group trial 0232 become available.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Urinary Symptom Flare in 712 {sup 125}I Prostate Brachytherapy Patients: Long-Term Follow-Up

Purpose: To describe the late transient worsening of urinary symptoms ('urinary symptom flare') in 712 consecutive prostate brachytherapy patients, associated predictive factors, association with rectal and urinary toxicity, and the development of erectile dysfunction. Methods and Materials: Patients underwent implantation between 1998 and 2003 (median follow-up, 57 months). International Prostate Symptom Score (IPSS), Radiation Therapy Oncology Group (RTOG) toxicity, and erectile function data were prospectively collected. Flare was defined as an increase in IPSS of >=5 and of >=8 points greater than the post-treatment nadir. The relationships between the occurrence of flare and the patient, tumor, and treatment characteristics were examined. The Cox proportional hazards method was used to test individual variables and the multivariate models. Results: The incidence of flare was 52% and 30% using the flare definition of an IPSS of >=5 and >=8 points greater than the postimplant nadir, respectively. Of the patients with symptoms, 65% had resolution of their symptoms within 6 months and 91% within 1 year. Flares most commonly occurred 16-24 months after implantation. On multivariate analysis, a greater baseline IPSS and greater maximal postimplant IPSS were the predictors of flare, regardless of the flare definition used. Androgen suppression was a predictor for fewer flares (IPSS >=5). Diabetes and prostate edema predicted for more frequent flares (IPSS >=8). Patients with flare had a greater incidence of RTOG Grade 3 urinary toxicity and RTOG Grade 2 or greater rectal toxicity. No association was found between erectile dysfunction and the occurrence of flare. Conclusion: Urinary symptom flare is a common, transient phenomenon after prostate brachytherapy. A greater baseline IPSS and maximal postimplant IPSS were the strongest predictive factors. Flare was associated with a greater incidence of late RTOG Grade 3 urinary toxicity and greater rate of late RTOG Grade 2 or greater rectal toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗