Search NASA⌕ Search

SEARCH · Search NASA

Results for “PV performance modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Feed-Forward Compensation for Model Predictive Control in Tri-port Current-Source Medium-Voltage String Inverters for PV-Plus-Storage Farms

The novel tri-port current-source medium-voltage string inverter (TCS-MVSI) is a promising candidate for large-scale PV-plus-storage (PVS) farms owing to its galvanic isolation, easy storage integration, soft-switching capability across entire load range, controlled low dv/dt and EMI, benign fault tolerance, etc. Due to its low inertia feature, traditional PI-based control cannot manage large transients effectively. Instead, a model-based predictive control (MPC) is proposed to achieve robust and stable operation. As is well known, the control performance of MPC is compromised by the sampling and computational delay during implementation significantly, if not well addressed. This paper analyzed and quantified these delays and then proposes feed-forward compensation (FFC) for the MPC method to compensate the delays and the large parameter variations due to the low-inertia nature. In addition, this method also compensates for the high dc-link ripple within each switching cycle, a unique issue for low-inertia converters. Here, the proposed method requires low computational effort, allowing it to be extended for multiple ports. The effectiveness of the proposed method has been validated in experiments. In 10 kW test, the proposed method decreases the average dc-link current by 17%, leading to ~20% conduction losses and ~0.5% increase in converter efficiency. In addition, the peak dc-link current also decreases by 15%, resulting in reduced transformer size. As a result, an increased power density can be achieved with the proposed method. Similar improvements have been observed across the power range from 2 kW to 10 kW.

30 DIRECT ENERGY CONVERSION↗

Technoeconomic Analysis of Changing PV System Layout and Convection Heat Transfer

This work includes analysis of potential economic improvements for PV systems for changing system parameters such as ground coverage ratio that alter the convective cooling consideration on PV modules through a newly proposed convective curve fit. Accounting for the spatial layout of the system in the convection heat transfer calculations allows for more accuracy in convective cooling load and subsequent module temperature calculations. The changing heat transfer considerations can be shown to improve system LCOE along with improved incident irradiance from increased row spacing despite the additional system costs incurred with increased module spacing. State-level analyses show that the impact of decreasing system GCR is greatest for climates with cold average annual ambient temperatures and moderate to high average annual wind speeds. Further waterfall analysis of changing system parameters reveals that the changing heat transfer dynamics have a non-negligible impact on system LCOE when compared to the changes in incident irradiance that serve as the primary driver of annual energy performance changes.

ENERGY PLANNING, POLICY, AND ECONOMY,SOLAR ENERGY↗

Methods for Evaluating DC Arc Incident Energy in PV Systems: Preprint

Renewable energy systems continue to be one of the fastest growing segments of the energy industry. This paper focuses on the understanding of how photovoltaic (PV) technology behaves under dc arc conditions. Emphasis is placed on the electrical safety aspect of DC arc flash incident energy evaluation. Because of the fast proliferation of PV systems and the lack of formal equivalent calculation guidelines such as IEEE 1584 for AC systems, it has been necessary to rely on different equations and models presented by various researchers over the last few years. This paper discusses the behavior of PV systems under arc conditions and presents the results of available methods to estimate the dc arc flash incident energy. This paper provides a comparative analysis of a proposed arc-flash incident energy calculation method against different laboratory tests including those performed by NREL. Detailed explanations are provided regarding the effect of PV module I-V and P-V curves under arcing conditions. Examples of the application of the proposed calculation method to the test measurements are included.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Viewfactor and Raytracing for AgriPV Modeling

View factor models are used in due diligence software to calculate rear irradiance for bifacial modules. An intermediate step in this calculation is the irradiance at the ground level, which can be leveraged for evaluating the Photo Active Radiation available for crops in Agrivoltaic setups. This paper presents the metrics and modifications to the model for ground irradiance study with the view factor approach, compares it to the raytracing method, and validates it with field measurements of ground irradiance. It is found that for the clearances, row-to-row setups, and tilts studied, the view factor method matches with raytracing results within 2% MBD. The comparison is performed for the nine most common agriPV configurations using high-performance computing and the NSRDB database for the whole US, with results and data made available open-source on the InSPIRE AgriPV website.

AgriPV↗

Regional Real-Time PV Spinning Reserve Estimator

Curtailed photovoltaic (PV) generation is a zero-marginal-cost spinning reserve that can be used for a number of active power control services. Unlike traditional spinning reserve providers, however, i.e., fossil-fueled generators, which have well-defined operating characteristics, e.g., available headroom or potential high limit (PHL), PV plants have by nature variable and uncertain operating characteristics. To ensure the effective coordination between PV plants and the system operator during an active power control event, accurate knowledge of the PV PHL is essential. It ensures that enough headroom is reserved by the PV plants to deliver the award services in real time and informs feasible dispatch decisions made by the market operator. To tackle this challenge, a novel reference-control grouping-based PV plant reserve estimation method has been proposed by the National Renewable Energy Laboratory under past projects funded by the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Solar Energy Technologies Office. The estimation method separates inverters within a plant into two groups: a control group and a reference group. While the reference group is reserved to operate at its PHL, the control group can be curtailed to provide the grid services. Real-time outputs from the reference inverters are used to estimate the PHL for the whole plant based on the ratio between capacities of the reference group and of the plant. This work further enhances the methodology by (1) improving the model accuracy through machine learning; (2) automating the reference inverter selection through correlation analysis; (3) considering estimation look-ahead windows; and (4) applying to regional spinning reserve estimation. Significant performance improvement has been observed based on real-world data collected by CAISO, Southern Company, and Terabase Energy. Compared with the original scaling method, the newly proposed machine learning-based approach reduces the estimation errors by 30% and 13% at the plant level and region level, respectively. Results obtained from this project are intended to be used by grid operators, market operators, balancing authorities, and PV plant owners and operators to facilitate PV participation in ancillary service markets. Regulators, policymakers, and system planners can also consider the results of this work in their decision-making processes. In addition to the performance improvement on the existing reference-control based grouping method, we also investigated how the variability of PV generation from a single PV inverter can be used to represent the variability of PV generation at the plant level.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimization and performance of bifacial solar modules: A global perspective

With the rapidly growing interest in bifacial photovoltaics (PV), a worldwide map of their potential performance can help assess and accelerate the global deployment of this emerging technology. However, the existing literature only highlights optimized bifacial PV for a few geographic locations or develops worldwide performance maps for very specific configurations, such as the vertical installation. It is still difficult to translate these location- and configuration-specific conclusions to a general optimized performance of this technology. In this paper, we present a global study and optimization of bifacial solar modules using a rigorous and comprehensive modeling framework. Our results demonstrate that with a low albedo of 0.25, the bifacial gain of ground-mounted bifacial modules is less than 10% worldwide. However, increasing the albedo to 0.5 and elevating modules 1 m above the ground can boost the bifacial gain to 30%. Moreover, we derive a set of empirical design rules, which optimize bifacial solar modules across the world and provide the groundwork for rapid assessment of the location-specific performance. We find that ground-mounted, vertical, east-west-facing bifacial modules will outperform their south-north-facing, optimally tilted counterparts by up to 15% below the latitude of 30 degrees, for an albedo of 0.5. The relative energy output is reversed in latitudes above 30 degrees. A detailed and systematic comparison with data from Asia, Africa, Europe, and North America validates the model presented in this paper.

14 SOLAR ENERGY↗

Spectral and Concentration Sensitivity of Multijunction Solar Cells at High Temperature

We model the performance of two-junction solar cells at very high temperatures up to ~400 degrees C for applications such as hybrid PV/solar-thermal power production. We show that high-temperature operation reduces the sensitivity of the cell efficiency to spectral content, but increases the sensitivity to concentration, both of which have implications for energy yield in terrestrial PV applications. For other high-temperature applications such as near-sun space missions, our findings indicate that concentration may be a useful tool to enhance cell efficiency.

14 SOLAR ENERGY↗

Building America Case Study: Retrofitting a 1960s Split-Level, Cold-Climate Home, Westport, Connecticut; Whole-House Solutions for Existing Homes, Energy Efficiency & Renewable Energy (EERE)

??National programs such as Home Performance with ENERGY STAR(R) and numerous other utility air sealing programs have brought awareness to homeowners of the benefits of energy efficiency retrofits. Yet, these programs tend to focus on the low-hanging fruit: air-sealing the thermal envelope and ductwork where accessible, switch to efficient lighting, and low-flow fixtures. At the other end of the spectrum, deep-energy retrofit programs are also being encouraged by various utilities across the country. While deep energy retrofits typically seek 50% energy savings, they are often quite costly and most applicable to gut-rehab projects. A significant potential for lowering energy usage in existing homes lies between the low hanging fruit and deep energy retrofit approaches - retrofits that save approximately 30% in energy over the existing conditions. A key is to be non-intrusive with the efficiency measures so the retrofit projects can be accomplished in occupied homes. This cold climate retrofit project involved the design and optimization of a home in Connecticut that sought to improve energy savings by at least 30% (excluding solar PV) over the existing home's performance. This report documents the successful implementation of a cost-effective solution package that achieved performance greater than 30% over the pre-retrofit - what worked, what did not, and what improvements could be made. Confirmation of successfully achieving 30% source energy savings over the pre-existing conditions was confirmed through energy modeling and comparison of the utility bills pre- and post- retrofit.

1960 split level↗

Band Bending at CdTe Solar Cell Contacts: Correlating Electro‐Optical and X‐Ray Photoelectron Spectroscopy Analyses of Thin Film Solar Cells

With the semiconductor bulk properties reaching target values for highly efficient solar cells, efforts are applied to reduce losses at solar cell interfaces and contacts. Advances in understanding back contacts in thin‐film polycrystalline CdTe solar cells, a leading thin‐film PV technology, are reported. By using X‐Ray photoelectron spectroscopy, Kelvin probe spectroscopy, time‐ and energy‐resolved photoluminescence, defects at the back contact are analyzed. Densities of recombination centers and charged defects that induce near‐back‐contact band bending, both resulting in recombination losses, were estimated. Electro‐optical and surface analysis results are integrated into a device model, simulating the performance of CdSeTe/CdTe solar cells with 902 mV open circuit voltage.

14 SOLAR ENERGY↗

Advanced Photovoltaic Module Characterization: Using Image Transformers for Current–Voltage Curve Prediction From Electroluminescence Images

Individual photovoltaic (PV) module health monitoring can be a daunting task for operation and maintenance of solar farms. Modules can be inspected through luminescence, thermal imaging, and current–voltage (I–V) curve analyzes for identification of damage and power loss. I–V curves provide easily interpretable data to determine module health as they directly provide electrical performance metrics. However, in order to obtain these curves, modules must be disconnected from the array and either removed to a solar simulator or characterized in situ with corrections for module temperature, the incident solar spectrum, and intensity. Luminescence or thermal images of a module are relatively easy to acquire in situ. Electroluminescence (EL) images highlight physical defects in the modules but do not provide easily interpretable features to correlate with electrical performance. This work presents a SWin transformer network to predict I–V curves for PV modules from their corresponding EL images. The predicted I–V curves allow the accurate prediction of the maximum power point (MPP), short-circuit current I sc , and open-circuit voltage V oc with a mean error less of than 1%. Comparing single diode model (SDM) parameters extracted from the predicted curves to those extracted from the true curves, the series resistance R s demonstrates a mean error of 5.19%, and the photocurrent I a mean error of 0.197%. The shunt resistance R sh and dark current Io parameters are predicted with larger errors because of their sensitivity to small changes in the I–V curve.

Byford, Brandon K. [New Mexico State Univ., Las Cr↗

Final Technical Report: Distributed Controls for High Penetrations of Renewables

The goal of this effort was to apply four potential control analysis/design approaches to the design of distributed grid control systems to address the impact of latency and communications uncertainty with high penetrations of photovoltaic (PV) generation. The four techniques considered were: optimal fixed structure control; Nyquist stability criterion; vector Lyapunov analysis; and Hamiltonian design methods. A reduced order model of the Western Electricity Coordinating Council (WECC) developed for the Matlab Power Systems Toolbox (PST) was employed for the study, as well as representative smaller systems (e.g., a two-area, three-area, and four-area power system). Excellent results were obtained with the optimal fixed structure approach, and the methodology we developed was published in a journal article. This approach is promising because it offers a method for designing optimal control systems with the feedback signals available from Phasor Measurement Unit (PMU) data as opposed to full state feedback or the design of an observer. The Nyquist approach inherently handles time delay and incorporates performance guarantees (e.g., gain and phase margin). We developed a technique that works for moderate sized systems, but the approach does not scale well to extremely large system because of computational complexity. The vector Lyapunov approach was applied to a two area model to demonstrate the utility for modeling communications uncertainty. Application to large power systems requires a method to automatically expand/contract the state space and partition the system so that communications uncertainty can be considered. The Hamiltonian Surface Shaping and Power Flow Control (HSSPFC) design methodology was selected to investigate grid systems for energy storage requirements to support high penetration of variable or stochastic generation (such as wind and PV) and loads. This method was applied to several small system models.

14 SOLAR ENERGY↗

Best practices for photovoltaic performance loss rate calculations

Abstract The performance loss rate (PLR) is a vital parameter for the time-dependent assessment of photovoltaic (PV) system performance and health state. Although this metric can be calculated in a relatively straightforward manner, it is challenging to achieve accurate and reproducible results with low uncertainty. Furthermore, the temporal evolution of PV system performance is usually nonlinear, but in many cases a linear evaluation is preferred as it simplifies the assessment and it is easier to evaluate. As such, the search for a robust and reproducible calculation methodology providing reliable linear PLR values across different types of systems and conditions has been the focus of many research activities in recent years. In this paper, the determination of PV system PLR using different pipelines and approaches is critically evaluated and recommendations for best practices are given. As nonlinear PLR assessments are fairly new, there is no consent on how to calculate reliable values. Several promising nonlinear approaches have been developed recently and are presented as tools to evaluate the PV system performance in great detail. Furthermore, challenges are discussed with respect to the PLR calculation but also opportunities for differentiating individual performance losses from a generic PLR value having the potential of enabling actionable insights for maintenance.

14 SOLAR ENERGY↗

Improved PV System Control Strategies to Reduce Power Management Costs in Nanogrids

An improved PV system control method is proposed to reduce nanogrid operation costs in this paper. A model including it various components such as photovoltaic (PV) systems, energy storage systems (ESSs), gateways, and household loads is considered with the constraints of the ESS, PV irradiance from real data, and household load. We designed an optimal economic dispatch strategy with an improved PV system control method. Combining the proposed optimal economic dispatch and PV system control strategies, it can improve the control performance for both transient and steady-state responses thereby enabling the maximum power to be extracted from the PV. Consequently, the PV power is maximized, which allows the ESS to use less power and sell the surplus to external power sources, which means the proposed method decreases the nanogrid operation costs. Furthermore, this performance is verified via nanogrid simulations and PV experimental kit.

PV system control↗

Machine learning with knowledge constraints for process optimization of open-air perovskite solar cell manufacturing

Perovskite photovoltaics (PV) have achieved rapid development in the past decade in terms of power conversion efficiency of small-area lab-scale devices; however, successful commercialization still requires further development of low-cost, scalable, and high-throughput manufacturing techniques. One of the critical challenges of developing a new fabrication technique is the high-dimensional parameter space for optimization, but machine learning (ML) can readily be used to accelerate perovskite PV scaling. Herein, we present an ML-guided framework of sequential learning for manufacturing process optimization. We apply our methodology to the Rapid Spray Plasma Processing (RSPP) technique for perovskite thin films in ambient conditions. With a limited experimental budget of screening 100 process conditions, we demonstrated an efficiency improvement to 18.5% as the best-in-our-lab device fabricated by RSPP, and we also experimentally found 10 unique process conditions to produce the top-performing devices of more than 17% efficiency, which is 5 times higher rate of success than the control experiments with pseudo-random Latin hypercube sampling. Our model is enabled by three innovations: (a) flexible knowledge transfer between experimental processes by incorporating data from prior experimental data as a probabilistic constraint; (b) incorporation of both subjective human observations and ML insights when selecting next experiments; (c) adaptive strategy of locating the region of interest using Bayesian optimization first, and then conducting local exploration for high-efficiency devices. Furthermore, in virtual benchmarking, our framework achieves faster improvements with limited experimental budgets than traditional design-of-experiments methods (e.g., one-variable-at-a-time sampling). This framework shows the capability of incorporating researchers’ domain knowledge into the ML-guided optimization loop; therefore, it has the potential to facilitate the wider adoption of ML in scaling to perovskite PV manufacturing.

14 SOLAR ENERGY↗

Experimental investigation and modeling of a direct-coupled PV/T air collector

Photovoltaic/thermal (PV/T) systems refer to the integration of photovoltaic and solar thermal technologies into one single system, in that both useful heat energy and electricity are produced. The impetus of this paper is to model a direct-coupled PV/T air collector which is designed, built, and tested at a geographic location of Kerman, Iran. In this system, a thin aluminum sheet suspended at the middle of air channel is used to increase the heat exchange surface and consequently improve heat extraction from PV panels. This PV/T system is tested in natural convection and forced convection (with two, four and eight fans operating) and its unsteady results are presented in with and without glass cover cases. A theoretical model is developed and validated against experimental data, where good agreement between the measured values and those calculated by the simulation model were achieved. Comparisons are made between electrical performance of the different modes of operation, and it is concluded that there is an optimum number of fans for achieving maximum electrical efficiency. Also, results show that setting glass cover on photovoltaic panels leads to an increase in thermal efficiency and decrease in electrical efficiency of the system. (author)

14 SOLAR ENERGY↗

Advanced Inverter Voltage Controls: Simulation and Field Pilot Findings

This report describes work performed by the Hawaiian Electric Companies and the National Renewable Energy Laboratory (NREL) to model and simulate advanced inverter grid-support functions and to validate and expand on those simulations through a field pilot study. This work builds on earlier research, referred to as the Voltage Regulation Operational Strategies study. The objective of both is to investigate functionalities available in most photovoltaic (PV) inverters to modulate active and reactive power autonomously based on local voltage measurements for the purpose of mitigating off-nominal grid voltage conditions. Specifically of interest are volt/volt-ampere reactive (VAR) control and volt/watt control, the effect of those functions on quasi-steady-state feeder voltages, and the impact of the functions on PV energy production. Because volt/VAR and volt/watt control autonomously adjust inverter output based on local conditions without requiring communication with any other devices, they are good candidates to increase PV hosting capacity when it is limited by voltage constraints in a feeder with very large numbers of PV systems.

14 SOLAR ENERGY↗

Improved Creep-­Fatigue Models on Advanced Materials for SFR Applications (Final Report)

This report provides an update on the materials performance criteria and methodology relevant to sodium-cooled fast reactors (SFRs). The report is the second deliverable (Level 2) in FY11 (M2A11AN040303) under the work package A-11AN040303 “Materials Performance Criteria and Methodology” as part of the Advanced Structural Materials Program for the Advanced Reactor Concepts. The overall objective of the Materials Performance Criteria and Methodology work project is to evaluate the key requirements for the ASME Code qualification and the Nuclear Regulatory Commission (NRC) approval of advanced structural materials in support of the design and performance of sodium-cooled fast reactors. Advanced materials are a critical element in the development of fast reactor technologies. Enhanced materials performance not only improves safety margins and provides design flexibility, but also is essential for the economics of future advanced fast reactors. Qualification and licensing of advanced materials are prominent needs for the development and implementation of advanced fast reactor technologies. Nuclear structural component designs in the U.S. comply with the ASME Boiler and Pressure Vessel (B&PV) Code Section III (Rules for Construction of Nuclear Facility Components), and the NRC grants licensing. As the SFRs will operate at higher temperatures than the current light water reactors (LWRs), the design of elevated-temperature components must comply with ASME Section III Subsection NH (Class 1 Components in Elevated Temperature Service). A number of technical issues relevant to materials performance criteria and high temperature design methodology in the SFR were identified and presented in earlier reports. A viable approach to resolve these issues and the R&D priority were also recommended. The development of mechanistically based creep-fatigue interaction models for life prediction and reliable data extrapolation was chosen to be the central focus in near-term efforts. Our current focus is on the creep-fatigue damage issue in high-strength ferritic/martensitic steels such as mod.9Cr-1Mo (G91) and NF616 (G92) steels. The current ASME creep-fatigue design rule puts severe limits of fatigue and creep loads for G91 steel, the lead structural material for fast reactors. High-strength ferritic/martensitic steels behave fundamentally differently from austenitic stainless steels, for which the current ASME creep-fatigue design rules were developed. The unique deformation and damage characteristics in G91 steel, e.g. cyclic softening, degradation of creep and rupture strength during cyclic service, demands a new creep-fatigue design procedure that explicitly accounts for the material’s unique creep-fatigue behavior. G92 steel, a variant of G91 steel, is the lead candidate in the Advanced Alloy Development program. There is currently no creep-fatigue design rule available for this advanced alloy. To support the predictive model development and resolve the over-conservative issue with the ASME design rule for G91 steel, we recovered stress relaxation data from thirteen creep-fatigue tests conducted in the late 1980s and early 1990s at Oak Ridge National Laboratory, and conducted extensive data analysis in FY10. Based on this database and available literature data, we have developed a Cyclic Softening Model and a Stress Relaxation Model specifically applied to G91 steel. The Cyclic Softening Model describes the cyclic stress variation as a function of cycle number during creep-fatigue loading, and well captures the cyclic softening effect in G91 steel. The Stress Relaxation Model predicts the stress relaxation curve during the hold time of cyclic loading, and its dependence on the cyclic softening effect of G91 steel. Two creep-fatigue test systems have been set up to conduct model-oriented creep-fatigue experiments. Results from three creep-fatigue experiments on Heat 30176 of G91 steel are presented in the report: (1) a test performed at 550°C with total strain amplitude of 0.25% and a hold time of 60 s applied at peak strains in both tension and compression, (2) a test performed at 400°C with total strain amplitude of 0.5% and a tension and compression hold time of 60 s, and (3) a test performed at 20°C with total strain amplitude of 0.5% and a tension and compression hold time of 60 s. Three different test temperatures were chosen for two primary reasons: to determine the transition temperature of creep-fatigue interaction from a plasticity-dominated process to a creep-dominated process; to develop unified creep-fatigue models applicable for a wide range of temperatures. With the detailed information obtained in the creep-fatigue experiments, we have further refined the Cyclic Softening Model and Stress Relaxation Model. The Cyclic Softening Model and Stress Relaxation Model were incorporated into the Bilinear Creep-Fatigue Damage Model, forming a powerful framework for the life prediction by an improved creep-fatigue evaluation methodology. The cyclic softening and consecutive stress relaxation responses in G91 steel can be considered for each cycle of the entire cyclic process in the model calculation. The creep-fatigue damage in G91 steel was evaluated using the improved Bilinear Creep-Fatigue Damage Model without any safety margins. It was found that due to the significant cyclic softening in G91 steel, the unit creep damage in each cycle decreased continuously with increasing number of cycles. This continuous change in creep damage with cycling has significant implication in the evaluation of the total creep-fatigue damage. The total creep damage can be one order of magnitude lower when the unit creep damage at half-life was used in the evaluation in comparison with the calculations using the unit creep damage at cycle 10. An important conclusion was that the accurate assessment of the creep-fatigue damage in G91 steel must consider the history of cycling. This analysis provides a more realistic assessment of creep-fatigue damage and identifies critical factors that must be considered in the development of future advanced models for high-strength ferritic/martensitic alloys. An accelerated creep-fatigue testing methodology is proposed for the design of model-oriented experiments to guide and validate model developments. Future work will focus on creep-fatigue experiments of both G91 and G92 steels, and development of creep-fatigue models applicable to advanced ferritic/martensitic alloys. The Cyclic Softening Model and Stress Relaxation Model will be improved by incorporating microstructural parameters of dislocation density, subgrain structure, and second-phase particles. Collaborative modeling of combined Cyclic Softening Model, Stress Relaxation Model, and Interactive Damage Rate Model will be pursued for life prediction under creep-fatigue loading with extended hold time. Accelerated, well-controlled creep-fatigue tests will be conducted to provide high-quality experimental data to refine key material parameters and validate models.

Li, Meimei↗

Test Protocols for Advanced Inverter Interoperability Functions - Appendices

Distributed energy resources (DER) such as photovoltaic (PV) systems, when deployed in a large scale, are capable of influencing significantly the operation of power systems. Looking to the future, stakeholders are working on standards to make it possible to manage the potentially complex interactions between DER and the power system. In 2009, the Electric Power Research Institute (EPRI), Sandia National Laboratories (SNL) with the U.S. Department of Energy (DOE), and the Solar Electric Power Association (SEPA) initiated a large industry collaborative to identify and standardize definitions for a set of DER grid support functions. While the initial effort concentrated on grid-tied PV inverters and energy storage systems, the concepts have applicability to all DER. A partial product of this on-going effort is a reference definitions document (IEC TR 61850-90-7, Object models for power converters in distributed energy resources (DER) systems) that has become a basis for expansion of related International Electrotechnical Commission (IEC) standards, and is supported by US National Institute of Standards and Technology (NIST) Smart Grid Interoperability Panel (SGIP). Some industry-led organizations advancing communications protocols have also embraced this work. As standards continue to evolve, it is necessary to develop test protocols to independently verify that the inverters are properly executing the advanced functions. Interoperability is assured by establishing common definitions for the functions and a method to test compliance with operational requirements. This document describes test protocols developed by SNL to evaluate the electrical performance and operational capabilities of PV inverters and energy storage, as described in IEC TR 61850-90-7. While many of these functions are not now required by existing grid codes or may not be widely available commercially, the industry is rapidly moving in that direction. Interoperability issues are already apparent as some of these inverter capabilities are being incorporated in large demonstration and commercial projects. The test protocols are intended to be used to verify acceptable performance of inverters within the standard framework described in IEC TR 61850-90-7. These test protocols, as they are refined and validated over time, can become precursors for future certification test procedures for DER advanced grid support functions.

14 SOLAR ENERGY↗