Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

High spectral and spatial resolution observations of the 12.28 micron emission from H2 in the Orion Molecular Cloud

The pure rotational S(2) line of H2 at 12.28 microns was sought in 44 positions in the Orion Molecular Cloud with 6-arcsec beams and 35 km/s spectral resolution; and it was detected in 27 positions. The lines are approximately symmetric and have full widths at half-maximum ranging from 100 km/s down to the resolution limit. The distribution of intensities and line shapes is largely consistent with that observed in the 2-micron hydrogen transitions; however, unexpectedly complex line profiles and point-to-point variations in line shapes appear, particularly in the region near IRc9.

Beck, S. C.↗

A sensitive 1.5 GHz radio survey around the north ecliptic pole

A 29.3 sq deg region surrounding the north ecliptic pole (NEP; alpha = 18h00m, delta = +66 deg 30 min) was mapped with the Very Large Array at 1.5 GHz to support the deepest portion of the ROSAT all-sky soft X-ray survey. The resulting VLA-NEP survey catalog contains 2435 radio sources with flux densities in the range of 0.3-1000 mJy, including over 200 fainter than 1 mJy. The 28 fields of the inner 1.5 deg have noise levels sigma approximately equals 60 mu-Jy, and the 85 fields centered between 1.5 and 3.0 deg from the NEP have sigma approximately equals 120 mu-Jy. The typical spatial resolution is 20 sec HPBW, and most positions are accurate to less than 2 sec. Approximately 6% of the sources are found to be extended with size greater than 30 sec. We have compared the VLA-NEP catalog with four other radio catalogs made at lower resolution, as well as with the NASA Extragalactic Database and find counterparts for approximately 18% of the VLA-NEP objects. The normalized, differential radio source count is in agreement with previous studies. Between 1 and 150 mJy the slope of the log N-log S relation is 0.68 +/- 0.03. The catalog and related tables are available electronically.

Kollgaard, Ronald I.↗

High spectral and spatial resolution observations of the 12.28 micron emission from H2 in the Orion molecular cloud

The pure rotational S(2) line of molecular hydrogen at 12.28 microns was looked for in 44 positions in the Orion moleular cloud with 6 in. beams and 35 km/s spectral resolution; it was detected in 27 positions. Emission was observed over a velocity range of + or - 100 km/s. The lines are approximately symmetric, and have full widths at half maximum ranging from 100 km/s down to the resolution limit. The distribution of intensities and line shapes is largely consistent with that seen in the 2 micron hydrogen transitions. However, unexpectedly complex line profiles and point-to-point variations in linear shapes appear, particularly in the region near IRc9.

Beck, S. C.↗

Identification of the active site residues in ATP‐citrate lyase's carboxy‐terminal portion

Abstract ATP‐citrate lyase (ACLY) catalyzes production of acetyl‐CoA and oxaloacetate from CoA and citrate using ATP. In humans, this cytoplasmic enzyme connects energy metabolism from carbohydrates to the production of lipids. In certain bacteria, ACLY is used to fix carbon in the reductive tricarboxylic acid cycle. The carboxy(C)‐terminal portion of ACLY shows sequence similarity to citrate synthase of the tricarboxylic acid cycle. To investigate the roles of residues of ACLY equivalent to active site residues of citrate synthase, these residues in ACLY from Chlorobium limicola were mutated, and the proteins were investigated using kinetics assays and biophysical techniques. To obtain the crystal structure of the C‐terminal portion of ACLY, full‐length C. limicola ACLY was cleaved, first non‐specifically with chymotrypsin and subsequently with Tobacco Etch Virus protease. Crystals of the C‐terminal portion diffracted to high resolution, providing structures that show the positions of active site residues and how ACLY tetramerizes.

Nguyen, Vinh H.↗

Longitudinal sound waves in a collisionless, quasineutral plasma

The time evolution of slow sound waves in a homogeneous, collisionless and quasineutral plasma, in particular their Landau damping, is investigated using the kinetic-magnetohydrodynamics formulation of Ramos ( J. Plasma Phys. vol. 81, 2015 p. 905810325; vol. 82, 2016 p. 905820607). In this approach, the electric field is eliminated from a closed, hybrid fluid-kinetic system that ensures automatically the fulfilment of the charge neutrality condition. Considering the time dependence of a spatial-Fourier-mode linear perturbation with wavevector parallel to the equilibrium magnetic field, this can be cast as a second-order self-adjoint problem with a continuum spectrum of real and positive squared frequencies. Therefore, a conventional resolution of the identity with a continuum basis of singular normal modes is guaranteed, which simplifies significantly a Van Kampen-like treatment of the Landau damping. The explicit form of such singular normal modes is obtained, along with their orthogonality relations. These are used to derive the damped time evolution of the fluid moments of solutions of initial-value problems, for the most general kinds of initial conditions. The non-zero parallel electric field is not used explicitly in this analysis, but it is calculated from any given solution after the later has been obtained.

Physics↗

HESS-II reconstruction strategy and performance in the low-energy (20-150 GeV) domain

In mid-2009 a notable upgrade of the H.E.S.S. telescope system will take place: a new telescope with a 600 m{sup 2} mirror area and very-high-resolution camera (0.07 deg.) will be positioned at the centre of the present configuration, with the aim of lowering the threshold and enhance its sensitivity in the 100 GeV to several TeV energy range. HESS-II will permit the investigation of the lower energy {gamma}-ray spectra in various cosmic accelerators, giving information on the origin of the {gamma}-rays observed, and will detect AGNs with a redshift greater than 0.2 (being less affected by absorption by Extragalactic Background Light--EBL--in this energy range) and will search for new classes of very high energy {gamma}-ray emitters (pulsars, microquasars, GRB, and dark matter candidates)

79 ASTRONOMY AND ASTROPHYSICS↗

Coherency of su(1,1)-Barut-Girardello type and entanglement for spherical harmonics

Barut-Girardello coherent states corresponding to the (l-m)- and (l+m)-integer discrete irreducible representations of su(1,1) Lie algebra are calculated by the spherical harmonics Y{sub lm}({theta},{phi}). Their explicit compact forms and also, to realize the resolution of the identity, their corresponding positive definite measures on the complex plane are obtained in terms of the known functions. It is also shown that coherent states of both positive and negative representations separately lead us to construct new representation bases for su(1,1) Lie algebra. Then, it is shown that the su(1,1)-Barut-Girardello coherent states corresponding to two particles containing the spatial parity symmetries of a bipartite quantum system can be entangled in ten different ways.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of the microwave, terahertz, and far infrared spectra of monodeuterated methanol CH{sub 2}DOH up to J = 26, K = 11, and o{sub 1}

The first theoretical approach aimed at accounting for the energy levels of a non-rigid molecule displaying asymmetric-top asymmetric-frame internal rotation is developed. It is applied to a line position analysis of the high-resolution spectrum of the non-rigid CH{sub 2}DOH molecule and allows us to carry out a global analysis of a data set consisting of already available data and of microwave and far infrared transitions measured in this work. The analysis is restricted to the three lowest lying torsional levels (e{sub 0}, e{sub 1}, and o{sub 1}), to K ⩽ 11, and to J ⩽ 26. For the 8211 fitted lines, the unitless standard deviation is 2.4 and 103 parameters are determined including kinetic energy, hindering potential, and distortion effects parameters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Focal depth measurement of scanning helium ion microscope

When facing the challenges of critical dimension measurement of complicated nanostructures, such as of the three dimension integrated circuit, characterization of the focal depth of microscopes is important. In this Letter, we developed a method for characterizing the focal depth of a scanning helium ion microscope (HIM) by using an atomic force microscope tip characterizer (ATC). The ATC was tilted in a sample chamber at an angle to the scanning plan. Secondary electron images (SEIs) were obtained at different positions of the ATC. The edge resolution of the SEIs shows the nominal diameters of the helium ion beam at different focal levels. With this method, the nominal shapes of the helium ion beams were obtained with different apertures. Our results show that a small aperture is necessary to get a high spatial resolution and high depth of field images with HIM. This work provides a method for characterizing and improving the performance of HIM.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

MILLIMETER DUST EMISSION IN THE GQ LUP SYSTEM

We present SubMillimeter Array observations of the GQ Lup system at 1.3 mm wavelength with 0.''4 ({approx}60 AU) resolution. Emission is detected from the position of the primary star, GQ Lup A, and is marginally resolved. No emission is detected from the substellar companion, GQ Lup B, 0.''7 away. These data, together with models of the spectral energy distribution, suggest a compact disk around GQ Lup A with mass {approx}3 M {sub Jup}, perhaps truncated by tidal forces. There is no evidence for a gap or hole in the disk that might be the signature of an additional inner companion body capable of scattering GQ Lup B out to {approx}100 AU separation from GQ Lup A. For GQ Lup B to have formed in situ, the disk must have been much more massive and extended.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Low-Power, Radiation-Resistant, Silicon-Drift-Detector Array for Extraterrestrial Element Mapping

We are developing a modular Silicon Drift Detector (SDD) X-Ray Spectrometer (XRS) for measuring the abundances of light surface elements (C to Fe) fluoresced by ambient radiation on remote airless bodies. The value of fluorescence spectrometry for surface element mapping is demonstrated by its inclusion on three recent lunar missions and by exciting new data that have recently been announced from the Messenger Mission to Mercury. The SDD-XRS instrument that we have been developing offers excellent energy resolution and an order of magnitude lower power requirement than conventional CCDs, making much higher sensitivities possible with modest spacecraft resources. In addition, it is significantly more radiation resistant than x-ray CCDs and therefore will not be subject to the degradation that befell recent lunar instruments. In fact, the intrinsic radiation resistance of the SDD makes it applicable even to the harsh environment of the Jovian system where it can be used to map the light surface elements of Europa. In this paper, we first discuss our element-mapping science-measurement goals. We then derive the necessary instrument requirements to meet these goals and discuss our current instrument development status with respect to these requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pulse-resolved intensity measurements at a hard X-ray FEL using semi-transparent diamond detectors

Solid-state ionization chambers are presented based on thin diamond crystals that allow pulse-resolved intensity measurements at a hard X-ray free-electron laser (FEL), up to the 4.5 MHz repetition rate that will become available at the European XFEL. Due to the small X-ray absorption of diamond the thin detectors are semi-transparent which eases their use as non-invasive monitoring devices in the beam. FELs are characterized by strong pulse-to-pulse intensity fluctuations due to the self-amplified spontaneous emission (SASE) process and in many experiments it is mandatory to monitor the intensity of each individual pulse. Two diamond detectors with different electrode materials, beryllium and graphite, were tested as intensity monitors at the XCS endstation of the Linac Coherent Light Source (LCLS) using the pink SASE beam at 9 keV. The performance is compared with LCLS standard monitors that detect X-rays backscattered from thin SiN foils placed in the beam. In conclusion, the graphite detector can also be used as a beam position monitor although with rather coarse resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-C-207-01: Four-Dimensional Inverse Geometry Computed Tomography: Concept and Its Validation

Purpose: In past few years, the inverse geometry computed tomography (IGCT) system has been developed to overcome shortcomings of a conventional computed tomography (CT) system such as scatter problem induced from large detector size and cone-beam artifact. In this study, we intend to present a concept of a four-dimensional (4D) IGCT system that has positive aspects above all with temporal resolution for dynamic studies and reduction of motion artifact. Methods: Contrary to conventional CT system, projection data at a certain angle in IGCT was a group of fractionated narrow cone-beam projection data, projection group (PG), acquired from multi-source array which have extremely short time gap of sequential operation between each of sources. At this, for 4D IGCT imaging, time-related data acquisition parameters were determined by combining multi-source scanning time for collecting one PG with conventional 4D CBCT data acquisition sequence. Over a gantry rotation, acquired PGs from multi-source array were tagged time and angle for 4D image reconstruction. Acquired PGs were sorted into 10 phase and image reconstructions were independently performed at each phase. Image reconstruction algorithm based upon filtered-backprojection was used in this study. Results: The 4D IGCT had uniform image without cone-beam artifact on the contrary to 4D CBCT image. In addition, the 4D IGCT images of each phase had no significant artifact induced from motion compared with 3D CT. Conclusion: The 4D IGCT image seems to give relatively accurate dynamic information of patient anatomy based on the results were more endurable than 3D CT about motion artifact. From this, it will be useful for dynamic study and respiratory-correlated radiation therapy. This work was supported by the Industrial R&D program of MOTIE/KEIT [10048997, Development of the core technology for integrated therapy devices based on real-time MRI guided tumor tracking] and the Mid-career Researcher Program (2014R1A2A1A10050270) through the National Research Foundation of Korea funded by the Ministry of Science, ICT&Future Planning.

60 APPLIED LIFE SCIENCES↗

SU-F-T-567: Sensitivity and Reproducibility of the Portal Imaging Panel for Routine FFF QC and Patient Plan Dose Measurements

Purpose: The purpose of this work was to see if the EPID is a viable alternative to other QA devices for routine FFF QA and plan dose measurements. Methods: Sensitivity measurements were made to assess response to small changes in field size and beam steering. QA plans were created where field size was varied from baseline values (5–5.5cm, 20–20.5cm). Beam steering was adjusted by altering values in service mode (Symmetry 0–3%). Plans were measured using the Varian portal imager (aS1200 DMI panel), QA3 (Sun Nuclear), and Starcheck Maxi (PTW). FFF beam parameters as stated in Fogliata et al were calculated. Constancy measurements were taken using all 3 QC devices to measure a MLC defined 20×20cm field. Two clinical SABR patient plans were measured on a Varian Edge linac, using the Portal Dosimetry module in ARIA, and results compared with analysis made using Delta4 (ScandiDos). Results: The EPID and the Starcheck performed better at detecting clinically relevant changes in field size with the QA3 performing better when detecting similar changes in beam symmetry. Consistency measurements with the EPID and Starcheck were equivalent, with comparable standard deviations. Clinical plan measurements on the EPID compared well with Delta4 results at 3%/1mm. Conclusion: Our results show that for FFF QA measurements such as field size and symmetry, using the EPID is a viable alternative to other QA devices. The EPID could potentially be used for QC measurements with a focus on geometric accuracy, such as MLC positional QA, due to its high resolution compared to other QA devices (EPID 0.34mm, Starcheck 3mm, QA3 5mm). Good agreement between Delta4 and portal dosimetry also indicated the EPID may be a suitable alternative for measurement of clinical plans.

60 APPLIED LIFE SCIENCES↗

2D Polyhedral Template Matching for Atomic Resolution Microscopy

SAND2024-13879O The 2D Polyhedral Template Matching for Atomic Resolution Microscopy is a suite of functions for analyzing atomic resolution electron microscopy images using the 2D polyhedral template matching (2D-PTM) method. This software analyzes atomic resolution microscopy data from electron microscopic imaging or scanning probe microscopies. The primary application is for identifying different crystal phases, crystal orientations, and defect structures obtained in such atomic resolution images. Written in MATLAB and starting from an atomic resolution image, the code identifies the positions of atomic intensity peaks. It then matches predefined structural templates to the local atomic environments. Outputs include the local structural identification, the template scaling factor and rotation angle, root-mean-squared deviation (RMSD), and centrosymmetry parameter.

Medlin, Douglas↗

Improving the spatial dynamic range of digital inline particle holography

Digital in-line holography (DIH) has been proven to provide three-dimensional droplet position, size, and velocity distributions with a single-camera. This data is crucial for understanding multi-phase flows. In this work, we examine the performance of this diagnostic in the limit of very small particles, on the order of a pixel in diameter and smaller, and propose a post-processing method to improve them: Lanczos interpolation. The Lanczos interpolation kernel is the digital implementation of the Whittaker sinc filter, and strikes a compromise between maintaining the spatial frequency ceiling of the original digital image and computational cost of the interpolation. Without Lanczos interpolation, or super-sampling, the ultimate detectable particle size floor is on the order of 4 pixel widths. We show in this work that this limit can be reduced by 50% or more with super-sampling, depending upon the desired diameter accuracy, and examine the effect of super-sampling on the resulting accuracy of the extracted size and position of spherical particles. Extending this resolution limit increases the overall detection efficiency of the diagnostic. Since this increases the spatial dynamic range of the diagnostic, it can also allow a larger field-of-view to be captured with the same particle size floor.

47 OTHER INSTRUMENTATION↗

Marine Corps Base Camp Lejeune Onslow Bay Seismic Sub-bottom

Critical military training and testing on lands along the nation’s coastal and estuarine shorelines are increasingly placed at risk because of development pressures in surrounding areas, impairments due to other anthropogenic disturbances, and increasing requirements for compliance with environmental regulations. The U.S. Department of Defense (DoD) intends to enhance and sustain its training and testing assets and to optimize its stewardship of natural resources through the development and application of an ecosystem-based management approach on DoD installations. To accomplish this goal, particularly for installations in estuarine/coastal environments, the Strategic Environmental Research and Development Program (SERDP) launched the Defense Coastal/Estuarine Research Program (DCERP) as a minimum 10-year effort at Marine Corps Base Camp Lejeune (MCBCL) in North Carolina. The results of the first six years of the program (DCERP1) are presented here.The overarching objectives of DCERP are to: (1) understand the effects of military training activities, infrastructure development, and other coastal military installations; (2) develop models, tools, and indicators to evaluate ecosystem health; and (3) recommend adaptive management strategies to sustain ecosystem natural resources within the context of an active military installation.This data package includes seismic sub-bottom profile data are from the shallow (-2 to -11.5m, NAVD88) nearshore region of Onslow Beach. Data were collected in 2007 using a high-resolution Edgetech Chirp 512i (average resolution of 10-20cm). The position of each data point was related to NAD83 using RTK-GPS. Data were collected at a frequency range of 0.5-8 kHz. Heave is apparent in the seismic profiles because no swell filter was applied during acquisition or post-processing. Post-processing was performed using Chesapeake Technology SonarWiz MAP5. Georeferenced .sd files (datums: UTM, Zone 18N, meters & NAVD88, meters) were generated using IVS Fledermaus Pro ver. 7.

54 ENVIRONMENTAL SCIENCES↗