Demonstration of a time-integrated short line of sight neutron imaging system for inertial confinement fusion

The Neutron Imaging System (NIS) is an important diagnostic for understanding implosions of deuterium-tritium capsules at the National Ignition Facility. While the detectors for the existing system must be positioned 28 m from the source to produce sufficient imaging magnification and resolution, recent testing of a new short line of sight neutron imaging system has shown sufficient resolution to allow reconstruction of the source image with quality similar to that of the existing NIS on a 11.6 m line of sight. The new system used the existing pinhole aperture array and a stack of detectors composed of 2 mm thick high-density polyethylene converter material followed by an image plate. In these detectors, neutrons enter the converter material and interact with protons, which recoil and deposit energy within the thin active layer of the image plate through ionization losses. The described system produces time-integrated images for all neutron energies passing through the pinhole. We present details of the measurement scheme for this novel technique to produce energy-integrated neutron images as well as source reconstruction results from recent experiments at NIF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resolution enhancement of lung 4D-CT via group-sparsity

Purpose: 4D-CT typically delivers more accurate information about anatomical structures in the lung, over 3D-CT, due to its ability to capture visual information of the lung motion across different respiratory phases. This helps to better determine the dose during radiation therapy for lung cancer. However, a critical concern with 4D-CT that substantially compromises this advantage is the low superior-inferior resolution due to less number of acquired slices, in order to control the CT radiation dose. To address this limitation, the authors propose an approach to reconstruct missing intermediate slices, so as to improve the superior-inferior resolution.Methods: In this method the authors exploit the observation that sampling information across respiratory phases in 4D-CT can be complimentary due to lung motion. The authors’ approach uses this locally complimentary information across phases in a patch-based sparse-representation framework. Moreover, unlike some recent approaches that treat local patches independently, the authors’ approach employs the group-sparsity framework that imposes neighborhood and similarity constraints between patches. This helps in mitigating the trade-off between noise robustness and structure preservation, which is an important consideration in resolution enhancement. The authors discuss the regularizing ability of group-sparsity, which helps in reducing the effect of noise and enables better structural localization and enhancement.Results: The authors perform extensive experiments on the publicly available DIR-Lab Lung 4D-CT dataset [R. Castillo, E. Castillo, R. Guerra, V. Johnson, T. McPhail, A. Garg, and T. Guerrero, “A framework for evaluation of deformable image registration spatial accuracy using large landmark point sets,” Phys. Med. Biol. 54, 1849–1870 (2009)]. First, the authors carry out empirical parametric analysis of some important parameters in their approach. The authors then demonstrate, qualitatively as well as quantitatively, the ability of their approach to achieve more accurate and better localized results over bicubic interpolation as well as a related state-of-the-art approach. The authors also show results on some datasets with tumor, to further emphasize the clinical importance of their method.Conclusions: The authors have proposed to improve the superior-inferior resolution of 4D-CT by estimating intermediate slices. The authors’ approach exploits neighboring constraints in the group-sparsity framework, toward the goal of achieving better localization and noise robustness. The authors’ results are encouraging, and positively demonstrate the role of group-sparsity for 4D-CT resolution enhancement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Elemental and lattice-parameter mapping of binary oxide superlattices of (LaNiO 3 ) 4 /(LaMnO 3 ) 2 at atomic resolution

We construct the elemental distribution and lattice strain maps from the measured atomic column positions in a (LaNiO3)(4)/(LaMnO3)(2) superlattice over a large field of view. The correlation between the distribution of B-cations and the lattice parameter in the form of Vegard's law is validated using atomic resolution energy dispersive x-ray spectroscopy (EDS). The maps show negligible Mn intermixing in the LaNiO3 layer, while Ni intermixing in the LaMnO3 layer improves away from the substrate interface to 9.5 atomic% from the 8th period onwards, indicating that the superlattice interfacial sharpness is established as the distance from the substrate increases. The maps allow an observation of the compositional defects of the B-sites, which is not possible by Z-contrast alone. Thus, this study demonstrates a promising approach for atomic scale correlative study of lattice strain and composition, and a method for the calibration of atomic resolution EDS maps.

composition↗

Design and Performance of the LCLS Cavity BPM System

In this paper we present the design of the beam position monitor (BPM) system for the LCLS undulator, which features a high-resolution X-band cavity BPM. Each BPM has a TM{sub 010} monopole reference cavity and a TM{sub 110} dipole cavity designed to operate at a center frequency of 11.384 GHz. The signal processing electronics features a low noise single-stage three-channel heterodyne receiver that has selectable gain and a phase locking local oscillator. We will discuss the system specifications, design, and prototype test results.

36 MATERIALS SCIENCE↗

Angle-resolving time-of-flight electron spectrometer for near-threshold precision measurements of differential cross sections of electron-impact excitation of atoms and molecules

This article presents a new type of low-energy crossed-beam electron spectrometer for measuring angular differential cross sections of electron-impact excitation of atomic and molecular targets. Designed for investigations at energies close to excitation thresholds, the spectrometer combines a pulsed electron beam with the time-of-flight technique to distinguish between scattering channels. A large-area, position-sensitive detector is used to offset the low average scattering rate resulting from the pulsing duty cycle, without sacrificing angular resolution. A total energy resolution better than 150 meV (full width at half maximum) at scattered energies of 0.5-3 eV is achieved by monochromating the electron beam prior to pulsing it. The results of a precision measurement of the differential cross section for electron-impact excitation of helium, at an energy of 22 eV, are used to assess the sensitivity and resolution of the spectrometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Far-field speckle correlations as a function of object position for microscopically distinguishing objects hidden in a randomly scattering medium

Super-resolution optical sensing is of critical importance in science and technology and has required prior information about an imaging system or obtrusive near-field probing. Additionally, coherent imaging and sensing in heavily scattering media such as biological tissue has been challenging, and practical approaches have either been restricted to measuring the field transmission of a single point source, or to where the medium is thin. We present the concept of far-subwavelength spatial sensing with relative object motion in speckle as a means to coherently sense through heavy scatter. Experimental results demonstrate the ability to distinguish nominally identical objects with nanometer-scale translation while hidden in randomly scattering media, without the need for precise or known location and with imprecise replacement. The theory and supportive illustrations presented provide the basis for super-resolution sensing and the possibility of virtually unlimited spatial resolution, including through thick, heavily scattering media with relative motion of an object in a structured field. This work provides enabling opportunities for material inspection, security, and biological sensing.

Hastings, Ryan L. (ORCID:0009000095977807)↗

A Novel Feature of Valence Quark Distributions in Hadrons

Examining the evolution of the maximum of valence quark distribution, qV, weighted by Bjorken x, h(x,t)≡xqV(x,t), it is observed that h(x,t) at the peak becomes a one-parameter function; h(xp,t)=Φ(xp(t)), where xp is the position of the peak, t=logQ2, and Q2 is the resolution scale. This observation is used to derive a new model-independent relation which connects the partial derivative of the valence parton distribution functions (PDFs) in xp to the quantum chromodynamics (QCD) evolution equation through the xp derivative of the logarithm of the function Φ(xp(t)). A numerical analysis of this relation using empirical PDFs results in an observation of the exponential form of the Φ(xp(t))=h(xp,t)=CeDxp(t) for leading to next-to-next leading order approximations of PDFs for the range of Q2, covering four orders in magnitude. The exponent, D, of the observed “height-position” correlation function converges with the increase in the order of approximation. This result holds for all the PDF sets considered. A similar relation is observed also for the pion valence quark distribution, indicating that the obtained relation may be universal for any non-singlet partonic distribution. The observed “height-position” correlation is used also to indicate that no finite number of exchanges can describe the analytic behavior of the valence quark distribution at the position of the peak at fixed Q2.

Leon, Christopher↗

Neutron Protein Crystallography: Beyond the Folding Structure

Neutron diffraction provides an experimental method of directly locating hydrogen atoms in proteins, a technique complementary to ultra-high-resolution X-ray diffraction. A neutron diffractometers for biological macromolecules has been constructed in Japan, and it has been used to determine the crystal structures of proteins up to resolution limits of 1.5-2.5 A. Results relating to hydrogen positions and hydration patterns in proteins have been obtained from these studies. Examples include the geometrical details of hydrogen bonds, the role of hydrogen atoms in enzymatic activity, CH{sub 3} configuration, H/D exchange in proteins and oligonucleotides, and the dynamical behavior of hydration structures, all of which have been extracted from these structural results and reviewed.

36 MATERIALS SCIENCE↗

Dynamical characteristics of Rydberg electrons released by a weak electric field

This paper discuss the dynamics of ultraslow electrons in the combined potential of an ionic core and a static electric field. With state-of-the-art detection it is possible to create such electrons through strong intense-field photoabsorption and to detect them via high-resolution time-of-flight spectroscopy despite their very low kinetic energy. The characteristic feature of their momentum spectrum, which emerges at the same position for different laser orientations, is derived and could be revealed experimentally with an energy resolution of the order of 1 meV.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Position-Sensitive Nuclear Spectroscopy with Pixel Detectors

State-of-the-art hybrid semiconductor pixel detectors such as Medipix2 are suitable for energy- and position-sensitive nuclear spectroscopy. In addition to excellent energy- and spatial-resolution, these devices can operate in spectroscopic, single-quantum counting and/or on-line tracking mode. A devoted compact USB-readout interface provides functionality and ease of operation. The compact and versatile Medipix2/USB radiation camera provides visualization, vacuum and room-temperature operation as a real-time portable active nuclear emulsion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structure of a Eurkaryotic CLC Transporter Defines an Intermediate State in the Transport Cycle

CLC proteins transport chloride (Cl{sup -}) ions across cell membranes to control the electrical potential of muscle cells, transfer electrolytes across epithelia, and control the pH and electrolyte composition of intracellular organelles. Some members of this protein family are Cl{sup -} ion channels, whereas others are secondary active transporters that exchange Cl{sup -} ions and protons (H{sup +}) with a 2:1 stoichiometry. We have determined the structure of a eukaryotic CLC transporter at 3.5 angstrom resolution. Cytoplasmic cystathionine beta-synthase (CBS) domains are strategically positioned to regulate the ion-transport pathway, and many disease-causing mutations in human CLCs reside on the CBS-transmembrane interface. Comparison with prokaryotic CLC shows that a gating glutamate residue changes conformation and suggests a basis for 2:1 Cl{sup -}/H{sup +} exchange and a simple mechanistic connection between CLC channels and transporters.

59 BASIC BIOLOGICAL SCIENCES↗

Structure of a Eukaryotic CLC Transporter Defines an Intermediate State in the Transport Cycle

CLC proteins transport chloride (Cl{sup -}) ions across cell membranes to control the electrical potential of muscle cells, transfer electrolytes across epithelia, and control the pH and electrolyte composition of intracellular organelles. Some members of this protein family are Cl{sup -} ion channels, whereas others are secondary active transporters that exchange Cl{sup -} ions and protons (H{sup +}) with a 2:1 stoichiometry. We have determined the structure of a eukaryotic CLC transporter at 3.5 angstrom resolution. Cytoplasmic cystathionine beta-synthase (CBS) domains are strategically positioned to regulate the ion-transport pathway, and many disease-causing mutations in human CLCs reside on the CBS-transmembrane interface. Comparison with prokaryotic CLC shows that a gating glutamate residue changes conformation and suggests a basis for 2:1 Cl{sup -}/H{sup +} exchange and a simple mechanistic connection between CLC channels and transporters.

59 BASIC BIOLOGICAL SCIENCES↗

X-ray structure of a soluble Rieske-type ferredoxin from Mus musculus

The 2.07 {angstrom} resolution X-ray crystal structure of a soluble Rieske-type ferredoxin from Mus musculus encoded by the gene Mm.266515 is reported. Although they are present as covalent domains in eukaryotic membrane oxidase complexes, soluble Rieske-type ferredoxins have not previously been observed in eukaryotes. The overall structure of the mouse Rieske-type ferredoxin is typical of this class of iron-sulfur proteins and consists of a larger partial {beta}-barrel domain and a smaller domain containing Cys57, His59, Cys80 and His83 that binds the [2Fe-2S] cluster. The S atoms of the cluster are hydrogen-bonded by six backbone amide N atoms in a pattern typical of membrane-bound high-potential eukaryotic respiratory Rieske ferredoxins. However, phylogenetic analysis suggested that the mouse Rieske-type ferredoxin was more closely related to bacterial Rieske-type ferredoxins. Correspondingly, the structure revealed an extended loop most similar to that seen in Rieske-type ferredoxin subunits of bacterial aromatic dioxygenases, including the positioning of an aromatic side chain (Tyr85) between this loop and the [2Fe-2S] cluster. The mouse Rieske-type ferredoxin was shown to be capable of accepting electrons from both eukaryotic and prokaryotic oxidoreductases, although it was unable to serve as an electron donor for a bacterial monooxygenase complex. The human homolog of mouse Rieske-type ferredoxin was also cloned and purified. It behaved identically to mouse Rieske-type ferredoxin in all biochemical characterizations but did not crystallize. Based on its high sequence identity, the structure of the human homolog is likely to be modeled well by the mouse Rieske-type ferredoxin structure.

36 MATERIALS SCIENCE↗

Formation of the First Peptide Bond: The Structure of EF-P Bound to the 70S Ribosome

Elongation factor P (EF-P) is an essential protein that stimulates the formation of the first peptide bond in protein synthesis. Here we report the crystal structure of EF-P bound to the Thermus thermophilus 70S ribosome along with the initiator transfer RNA N-formyl-methionyl-tRNAi (fMet-tRNA{sub i}{sup fMet}) and a short piece of messenger RNA (mRNA) at a resolution of 3.5 angstroms. EF-P binds to a site located between the binding site for the peptidyl tRNA (P site) and the exiting tRNA (E site). It spans both ribosomal subunits with its amino-terminal domain positioned adjacent to the aminoacyl acceptor stem and its carboxyl-terminal domain positioned next to the anticodon stem-loop of the P site-bound initiator tRNA. Domain II of EF-P interacts with the ribosomal protein L1, which results in the largest movement of the L1 stalk that has been observed in the absence of ratcheting of the ribosomal subunits. EF-P facilitates the proper positioning of the fMet-tRNA{sub i}{sup fMet} for the formation of the first peptide bond during translation initiation.

36 MATERIALS SCIENCE↗

High Resolution Structure of the ba3 Cytochrome c Oxidase from Thermus thermophilus in a Lipidic Environment

The fundamental chemistry underpinning aerobic life on Earth involves reduction of dioxygen to water with concomitant proton translocation. This process is catalyzed by members of the heme-copper oxidase (HCO) superfamily. Despite the availability of crystal structures for all types of HCO, the mode of action for this enzyme is not understood at the atomic level, namely how vectorial H{sup +} and e{sup -} transport are coupled. Toward addressing this problem, we report wild type and A120F mutant structures of the ba{sub 3}-type cytochrome c oxidase from Thermus thermophilus at 1.8 {angstrom} resolution. The enzyme has been crystallized from the lipidic cubic phase, which mimics the biological membrane environment. The structures reveal 20 ordered lipid molecules that occupy binding sites on the protein surface or mediate crystal packing interfaces. The interior of the protein encloses 53 water molecules, including 3 trapped in the designated K-path of proton transfer and 8 in a cluster seen also in A-type enzymes that likely functions in egress of product water and proton translocation. The hydrophobic O{sub 2}-uptake channel, connecting the active site to the lipid bilayer, contains a single water molecule nearest the Cu{sub B} atom but otherwise exhibits no residual electron density. The active site contains strong electron density for a pair of bonded atoms bridging the heme Fe{sub a3} and Cu{sub B} atoms that is best modeled as peroxide. The structure of ba{sub 3}-oxidase reveals new information about the positioning of the enzyme within the membrane and the nature of its interactions with lipid molecules. The atomic resolution details provide insight into the mechanisms of electron transfer, oxygen diffusion into the active site, reduction of oxygen to water, and pumping of protons across the membrane. The development of a robust system for production of ba{sub 3}-oxidase crystals diffracting to high resolution, together with an established expression system for generating mutants, opens the door for systematic structure-function studies.

59 BASIC BIOLOGICAL SCIENCES↗

Polaron and Exciton Delocalization in Oligomers of High-Performance Polymer PTB7

A key characteristic of organic photovoltaic cells is the efficient charge separation in the active layer. Sufficient delocalization of the positive polaron in organic photovoltaics is considered essential for the effective separation of the opposite charges and the suppression of recombination. Here we use light-induced EPR and ENDOR spectroscopy combined with DFT calculations to determine the electronic structure of the positive polaron in PTB7-type oligomers. Utilizing the superior spectral resolution of high-frequency (130 GHz) D-band EPR, the principal components of the g tensors were determined. Pulsed ENDOR spectroscopy at X-band allowed the measurement of H-1 hyperfine coupling constants. A comparison of g tensors and H-1 hyperfine coupling constants of the PTB7-type oligomers with the high-performance PTB7 polymer revealed a delocalization of the positive polaron in the polymer over about four monomeric units, corresponding to about 45 angstrom in length. Our current study thus not only determines the polaron delocalization length in PTB7 but also validates the approach combining EPR/ENDOR spectroscopy with DFT-calculated magnetic resonance parameters. This is of importance in those cases where oligomers of defined length are not easily obtained. In addition, the delocalization of the neutral triplet exciton was also determined in the oligomers and compared with polymer PTB7. The analysis revealed that the neutral triplet exciton is substantially more delocalized than the positive polaron, exceeding 10 monomeric units.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-F-T-61: Treatment Planning Observations for the CivaSheet Directional Brachytherapy Device Using VariSeed 9.0

Purpose: The VariSeed 9.0 brachytherapy TPS is recently available and has new features such as ability to rotate a brachytherapy source away from normal to the imaging plane. Consequently, a dosimetric analysis was performed for a directional brachytherapy source (CivaSheet) with tests of this functionality and experiences from clinical treatment planning were documented. These observations contribute to safe, practical, and accurate use of such new software features. Methods: Several tests were established to evaluate the new rotational feature, specific to the CivaSheet for the first patients treated using this new brachytherapy device. These included suitability of imaging slice-thickness and in-plane resolution, window/level adjustments for brachytherapy source visualization, commissioning the source physical length for performing rotations, and using different planar and 3D window views to identify source orientation. Additional CivaSheet-specific tests were performed to determine the dosimetric influence on target coverage: changing the source tilt angle, source positioning in the treatment plan based on the CivaSheet rectangular array of CivaDots, and influence of prescription depth on the necessary treatment margin for adequate target coverage. Results: Higher imaging-resolution produced better accuracy for source orientation and positioning, with sub-millimeter CT slice-thickness and in-plane resolution preferred. Source rotation was possible only in sagittal or coronal views. The process for validating source orientation required iteratively altering rotations then checking them in the 3D view, which was cumbersome given the absence of quantitative plan documentation to indicate orientation. Given the small Pd-103 source size, influence of source tilt within 30° was negligible for <1.0 cm. Influence of source position was important when the source was positioned in/out of the adjacent source plane, causing changes of 15%, 7%, and 3% at depths of 0.5, 0.7, and 1.0 cm. Conclusion: The new TPS rotational feature worked well, but several issues were identified to improve the treatment planning process. Research supported in part by CivaTech Oncology, Inc. for Dr. Rivard.

60 APPLIED LIFE SCIENCES↗

Performance tests of large area position-sensitive planar germanium detectors with conventional and amorphous contacts.

Large area position-sensitive planar germanium wafers are increasingly being used for a variety of gamma-ray imaging and tracking tasks. Position sensitivity can be achieved through measuring charge collected on orthogonal strip electrodes, and by digital pulse shape analysis. However, the development of this detector technology has been slow, and criteria to measure improved performance have not been well established. We have studied 93 and 88 mm square segmented detectors of 20 mm thickness made with conventional boron and lithium electrodes, and two 100 mm circular segmented detectors of 14 mm thickness with amorphous germanium contacts. We have compared these detectors with a planar detector of 15 mm thickness. Conventional energy resolution tests of individual strips are insufficient to fully categorize the performance of the position sensitive detectors. We propose some basic tests which can rapidly quantify any segmented detector characteristics, and show potential inadequacies which become important when imaging or tracking is attempted.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗