Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Flight performance of the Voyager electrical power system

The Voyager power subsystem is described, and its flight performance to date is discussed. Special attention is given to the performance of the primary power source radioisotope thermoelectric generators (RTGs), to the autonomous operation features of the power system, and to the load management strategy developed to maintain an adequate power margin during application of transient loads and as normal degradation reduces RTG capability. It is found that the flight performance of the power system has been without significant problems to date and that RTG performance has exceeded mission requirements.

Packard, L. A.↗

Performance of Low-Power Pulsed Arcjets

The Electric Propulsion Laboratory at UIUC has in place all the capability and diagnostics required for performance testing of low power pulsed and DC arcjets. The UIUC thrust stand is operating with excellent accuracy and sensitivity at very low thrust levels. An important aspect of the experimental setup is the use of a PID controller to maintain a constant thruster position, which reduces hysterisis effects. Electrical noise from the arcjet induces some noise into the thrust signal, but this does not affect the measurement.

Burton, Rodney L.↗

The ATS-6 power system: Hardware implementation and orbital performance

The Applications Technology Satellite-6 power system, a shunt-boost configuration, uses partial shunt regulation of the solar array and a boost regulator for control of battery power. Regulation is provided for three different operating modes: shunt, charge, and boost. This configuration achieves the highest efficiency of power transfer from the solar array to the loads. The excellent dynamic regulation and low output impedance of the power system virtually eliminated the problem of subsystem interactions on the power bus due to conducted interference from load current fluctuations. The performance of the power system continues to be excellent. The solar array degradation (18.5 percent) was less than the specified 20 percent in two years in spite of extreme cycling from -160 C to 60 C. A unique battery cycling regime of discharges varying from 5 percent to 60 percent daily is being encountered. During the second year, noneclipse discharges have occurred twice a day to depths of 35 percent and 45 percent. Battery performance was good with only a small decrease in end-of-discharge voltage. A recent test to evaluate capacity gave 12.4 AH (83% of the nominal capacity of 15 AH) after over 1400 battery discharge cycles. A small increase in the end-of-charge voltage has recently occurred necessitating a change in the charge regime to achieve full charge conditions.

Lavigna, T. A.↗

Energy Storage Improves Power Plant Flexibility and Economic Performance

Most existing coal-fired power plants were designed for sustained operation at full load to maximize efficiency, reliability, and revenue, as well as to operate air pollution control devices at design conditions. Depending on plant type and design, these plants can adjust output within a fixed range in response to plant operating or market conditions. The need for flexibility driven by increased penetration of variable and non-dispatchable power generation, such as wind and solar, is shifting the traditional mission profile of thermoelectric power plants in three ways: more frequent shutdowns when market or grid conditions warrant, more aggressive load ramp rates (rate of output change), and a lower minimum sustainable load, which provides a wider operating range and helps avoid costly plant shutdowns. Recent studies have shown that the flexibility of a coal-fired power plant can be improved by energy storage. The objective of this work was to analyze a set of energy storage options and determine their impact on the flexibility and economics of a representative coal-fired power plant. The effect of three energy storage systems integrated with a coal power plant on plant flexibility and economics was investigated. The results obtained in this project show that energy storage systems integrated with a thermal power plant improve plant flexibility and participation in the energy and ancillary services markets, which improves plant financial performance.

20 FOSSIL-FUELED POWER PLANTS↗

Computational model for predicting the performance of fluid-powered longiudinal piston modules and motors.

A Matlab-based computational model line code has been developed for predicting the performance of fluid-powered longitudinal piston modules and motors. A system of equations has been developed based upon applying the conservation of mass to a control volume defined by a reciprocating piston. The method results in a differential equation that predicts the pressure gradient in the control volume as a function of rotor rotation angle. The model uses an integration scheme to predict the pressure state in the control volume. The orifice equation is used to predict the flowrate in and out of the control volume. From the resulting solution the torque and speed characteristics of the motor configuration can be predicted, optimized, or tailored for a specific requirement.SAND2019-13983 M Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Taylor, Michael↗

Resilience Metrics for the Electric Power System: A Performance-Based Approach.

Grid resilience is a concept related to a power system's ability to continue operating and delivering power even in the event that low probability, high-consequence disruptions such as hurricanes, earthquakes, and cyber-attacks occur. Grid resilience objectives focus on managing and, ideally, minimizing potential consequences that occur as a result of these disruptions. Currently, no formal grid resilience definitions, metrics, or analysis methods have been universally accepted. This document describes an effort to develop and describe grid resilience metrics and analysis methods. The metrics and methods described herein extend upon the Resilience Analysis Process (RAP) developed by Watson et al. for the 2015 Quadrennial Energy Review. The extension allows for both outputs from system models and for historical data to serve as the basis for creating grid resilience metrics and informing grid resilience planning and response decision-making. This document describes the grid resilience metrics and analysis methods. Demonstration of the metrics and methods is shown through a set of illustrative use cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Life-Cycle Cost and Optimization of PV Systems Based on Power Duration Curve with Variable Performance Ratio and Availability

A new derivation of Power Duration Curve is presented and applied to analysis of photovoltaic system life cycle cost. The effect of non-unity Performance Ratio and non-unity Availability on the power duration curve are illustrated. The effect of these two key performance indicators on calculation of life cycle cost and PV system design optimization (optimal DC/AC ratio) are illustrated as example applications of the method.

14 SOLAR ENERGY↗

Improving the Performance of Integrated Power-Hardware-in-the-Loop and Quasi-Static Time-Series Simulations

This paper introduces a novel multirate cosimulation architecture that overcomes previous challenges integrating faster real-time, microseconds-scale, power-hardware-in-the-loop (PHIL) with larger scale but slower, real-time, seconds-scale, quasi-static time-series (QSTS) simulation. Specifically, an intermediate reduced-equivalent electromagnetic transient (EMT) model duplicates the key power system topology to capture high-speed dynamics and converge hardware-power system interactions between QSTS updates. Exchanging multidimensional parameter vectors (loads, control status, etc.) between the QSTS and EMT models enables capturing the interactions of the rich, high-node-count (thousands of electrical nodes) QSTS model with the hardware. This architecture offers full spatial resolution from QSTS, including individual load dynamics, actual distribution management system controls, and nodal voltages. Simultaneously, the intermediate EMT model provides more detailed high-speed transients of key distributed energy resource hardware interactions. In addition, we use careful PHIL interface design and the exchange of complex power data, rather than current, to further improve performance. This cosimulation architecture is demonstrated by testing a simulated distribution system with an interconnected 500-kVA advanced photovoltaic (PV) inverter in PHIL. In conclusion, the architecture successfully captured PV local volt-volt ampere reactive (volt-VAR) control interactions with the larger network under time-varying electrical and weather conditions.

42 ENGINEERING↗

Experimental investigation of PDI bifurcation of lower hybrid waves during electron density ramp-up in EAST

Abstract The effect of parametric decay instability (PDI) on the current drive efficiency of 4.6 GHz lower hybrid (LH) waves in EAST is investigated experimentally, showing the PDI channel bifurcation of LH waves for the first time in EAST. First, experiments with three platforms of LH power were performed, achieving the LH power required for the PDI occurrence. Second, PDI bifurcation experiments were further carried out by ramping up the plasma electron density. The loop voltage increases with an increase in density, implying a decrease in the current driven by the LH wave. PDI bifurcation during electron density ramp-up was studied by analyzing the parallel refractive index ( n ∥ ) and the frequency spectrum broadening, which is measured with a radio frequency magnetic probe array recently installed close to the LH antenna. It is observed for the first time that they both first increase with density, then there is not much variation and a clear sideband in the frequency spectrum is also observed when the density is up to 4 × 10 19 m − 3 , suggesting a change in the PDI channel. Calculation of the mode growth rate driven by PDI shows that when the edge electron density is up to 1.9 × 10 18 m − 3 , the growth rate of the ion cyclotron quasi-mode (ICQM) will exceed that of the ion sound quasi-mode (ISQM), quantitively explaining that with an increase in density, the PDI channel partly transits from the ISQM to the ICQM channel. Studies provide a possible way to reduce the power deposition in the edge region and improve drive capability by means of mitigating PDI behavior.

Physics↗

An Evaluation of the Network Simulators in Large-Scale Distributed Simulations

This is a survey paper about the state-of-the-art in large-scale network simulation. Networks for the smart grids are characterized by millions of sensor nodes exchanging information about the status of the grid. This information exchange must be realized reliably and efficiently due to the mission critical nature of the power grid. Hence, the applications and the network protocols developed for the smart grid need go through rigorous testing and analysis before deployment. Developers usually do not have access to such a large-scale network that can be used as a controlled test-bed; therefore, network simulation becomes an essential tool for testing. Network simulation is a well studied problem in the literature and there are various widely used network simulators. These simulators can be adopted for testing applications and protocols of the smart grid. Due to the scale of these networks, parallel/distributed simulations need to be conducted. Even though most network simulators support distributed simulations, generating a large-scale network model to simulate can still be a cumbersome task. In this survey, we describe a selection of commonly used network simulators and evaluate them with respect to the following features that can aid users in distributed simulations of large-scale networks: transparency of setting up distributed simulation, automated topology generation, information hiding, lightweight routing protocols, network error simulation, evaluation of the network model during simulation and trace analysis tools. As a complementary result, we identify two issues with network simulators that can be addressed with runtime steering methods.

99 GENERAL AND MISCELLANEOUS↗

Towards an Application-Specific Thermal Energy Model of Current Processors

Recent developments of high-end processors recognize temperature monitoring and tuning as one of the main challenges towards achieving higher performance given the growing power and temperature constraints. To address this challenge, one needs both suitable thermal energy abstraction and corresponding instrumentation. Our model is based on application-specific parameters such as power consumption, execution time, and asymptotic temperature as well as hardware-specific parameters such as half time for thermal rise or fall. As observed with our out-of-band instrumentation and monitoring infrastructure, the temperature changes follow a relatively slow capacitor-style charge-discharge process. Therefore, we use the lumped thermal model that initiates an exponential process whenever there is a change in processor’s power consumption. Initial experiments with two codes – Firestarter and Nekbone – validate our application-specific thermal model and demonstrate its use for analyzing and potentially improving the balance between temperature, power, and performance.

Getov, Vladimir S.↗

Chemical Looping Combustion Sensitivity Analyses: CLOU Concepts

The objective of the National Energy Technology Laboratory (NETL) effort described in this report is to generate a reference-CLOU power plant performance and cost screening assessment and associated sensitivity analyses. To do this, a review of the CLOU literature was first performed to establish a complete design basis for a reference-CLOU power plant. While complete design-basis information is not available for any CLOU oxygen carrier, a representative design basis was compiled from a variety of literature sources. The design basis was then applied to generate reference-CLOU power plant material and energy balances, the unique CLOU process equipment was approximately sized and specified, equipment cost estimates were developed, and total power plant performance, capital investment, and cost of electricity (COE) estimates were compiled. Major performance and cost sensitivity parameters were identified, and performance and cost sensitivity analyses were performed. The results are these analyses relate not only the performance and cost potential of CLOU power generation, but also provide guidance to CLOU oxygen carrier and process researchers and developers.

20 FOSSIL-FUELED POWER PLANTS↗

Power Electronics Module with Integrated Ceramic Heat Exchanger

NREL, in partnership with Synteris and Packet Digital, has developed a 3D-printable ceramic package for power electronic modules to improve their thermal management, power density, performance, and lifetime. Existing power modules contain flat ceramic substrates that serve as both the electrically insulating component and thermal conductor that transfer the large heat outputs of these devices. The team has developed an additive manufacturing process that replaces the traditional insulating metalized substrate, substrate attach, and baseplate/heat exchanger with an additively-manufactured ceramic packaging that acts as both an electrical insulator and heat exchanger for better thermal management. The design, manufacturability, and function of this power module will be discussed.

25 ENERGY STORAGE↗

Advanced Thermoelectric Materials for Efficient Waste Heat Recovery in Process Industries

The overall objective of the project was to integrate advanced thermoelectric materials into a power generation device that could convert waste heat from an industrial process to electricity with an efficiency approaching 20%. Advanced thermoelectric materials were developed with figure-of-merit ZT of 1.5 at 275 degrees C. These materials were not successfully integrated into a power generation device. However, waste heat recovery was demonstrated from an industrial process (the combustion exhaust gas stream of an oxyfuel-fired flat glass melting furnace) using a commercially available (5% efficiency) thermoelectric generator coupled to a heat pipe. It was concluded that significant improvements both in thermoelectric material figure-of-merit and in cost-effective methods for capturing heat would be required to make thermoelectric waste heat recovery viable for widespread industrial application.

30 DIRECT ENERGY CONVERSION↗