Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power system faults”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Diagnosing battery behavior with an expert system in PROLOG

Power for the Hubble Space Telescope comes from a system of 20 solar panel assemblies (SPAs) and six nickel-cadmium batteries. The HST battery system is simulated by the HST Electrical Power System (EPS) testbed at Marshall Space Flight Center. The Nickel Cadmium Battery Expert System (NICBES) is being used to diagnose faults of the testbed system, evaluate battery status and provide decision support for the engineer. Extensive telemetry of system operating conditions is relayed through a DEC LSI-11. A BASIC program running on a PC monitors the flow of data, figures cell divergence and recharge ratio, and stores these values, along with other selected data, for use by the expert system.

Kirkwood, N.↗

Space power system automation approaches at the George C. Marshall Space Flight Center

This paper discusses the automation approaches employed in various electrical power system breadboards at the Marshall Space Flight Center. Of particular interest is the application of knowledge-based systems to fault management and dynamic payload scheduling. A description of each major breadboard and the automation approach taken for each is given.

Weeks, D. J.↗

Adaptive Sampling using Support Vector Machines

Reliability/safety analysis of stochastic dynamic systems (e.g., nuclear power plants, airplanes, chemical plants) is currently performed through a combination of Event-Tress and Fault-Trees. However, these conventional methods suffer from certain drawbacks: • Timing of events is not explicitly modeled • Ordering of events is preset by the analyst • The modeling of complex accident scenarios is driven by expert-judgment For these reasons, there is currently an increasing interest into the development of dynamic PRA methodologies since they can be used to address the deficiencies of conventional methods listed above.

99 GENERAL AND MISCELLANEOUS↗

Electrical performance characteristics of high power converters for space power applications

The first goal of this project was to investigate various converters that would be suitable for processing electric power derived from a nuclear reactor. The implementation is indicated of a 20 kHz system that includes a source converter, a ballast converter, and a fixed frequency converter for generating the 20 kHz output. This system can be converted to dc simply by removing the fixed frequency converter. This present study emphasized the design and testing of the source and ballast converters. A push-pull current-fed (PPCF) design was selected for the source converter, and a 2.7 kW version of this was implemented using three 900 watt modules in parallel. The characteristic equation for two converters in parallel was derived, but this analysis did not yield any experimental methods for measuring relative stability. The three source modules were first tested individually and then in parallel as a 2.7 kW system. All tests proved to be satisfactory; the system was stable; efficiency and regulation were acceptable; and the system was fault tolerant. The design of a ballast-load converter, which was operated as a shunt regulator, was investigated. The proposed power circuit is suitable for use with BJTs because proportional base drive is easily implemented. A control circuit which minimizes switching frequency ripple and automatically bypasses a faulty shunt section was developed. A nonlinear state-space-averaged model of the shunt regulator was developed and shown to produce an accurate incremental (small-signal) dynamic model, even though the usual state-space-averaging assumptions were not met. The nonlinear model was also shown to be useful for large-signal dynamic simulation using PSpice.

Stuart, Thomas A.↗

Grey-box Fault Models and Applications for Low Carbon Emission CO2 Refrigeration System

CO2 refrigeration systems have attracted more attentions in recent years because of their zero-carbon emission advantages compared with traditional refrigerants. These systems are widely used in certain commercial buildings such as supermarkets. However, very limited energy studies have been done for such refrigeration systems under faults. Furthermore, this study investigated five common faults for supermarket transcritical CO2 refrigeration systems with display cases. The following major tasks were implemented for this study. (1) Five fault models (gray-box format) regarding the power consumption and supply air temperature were proposed for low- and high-temperature display cases, respectively. The models cover: ice accumulation on evaporator coil, evaporator fan partial failure, expansion valve failure, display door open, and condenser blockage. (2) These fault models were calibrated with field tests, and the modeling accuracies were in good agreement with measurement datasets. (3) The proposed fault models demonstrated more than 90% of fault detection for Fault Detection and Diagnostics (FDD) purposes for both field measurement and simulated data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Blackstart Capability and Survivability of Wind Turbines with Fully Rated Converters

We report the blackstart capability of wind turbines is critical for the recovery of wind-dominant power systems from blackouts. If wind power plants are not able to restore a power system, the incorporation of wind resources into electric grids could be limited by blackstart capability. This paper tackles this problem by setting forth a grid-forming controller for Type 4 wind turbines which employ fully rated power converters. To this end, we engineer two-axis anti-windup proportional-integral regulators that serve to ride through restoration disturbances. We also design an active protection system to prevent wind turbines from stalling during recovery from blackouts. We demonstrate in a high-fidelity simulation environment that Type 4 wind turbines with the developed controllers and protection subsystem can: (i) re-energize a notional wind-dominant grid; (ii) ride through asymmetrical faults; and (iii) survive low wind speed events.

17 WIND ENERGY↗

Investigating the Impact of Wind Turbines on Distribution System Stability

Modern wind turbines utilize power electronic converters to regulate their output and optimize their performance. Their impact on the distribution system is not as well understood as for transmission system. The novelty of this work is in studying the impact of wind turbines given its proximity to faults or severe voltage events, and the influence on system stability given its location relative to the substation (representing the conventional grid). This paper presents the frequency and voltage swing plots for various study scenarios. The responses are analyzed two fold - Steady state operation, and performance given a fault or voltage events occurs in the system. The findings are presented, with crucial differences from transmission systems highlighted.

17 WIND ENERGY↗

The KATE shell: An implementation of model-based control, monitor and diagnosis

The conventional control and monitor software currently used by the Space Center for Space Shuttle processing has many limitations such as high maintenance costs, limited diagnostic capabilities and simulation support. These limitations have caused the development of a knowledge based (or model based) shell to generically control and monitor electro-mechanical systems. The knowledge base describes the system's structure and function and is used by a software shell to do real time constraints checking, low level control of components, diagnosis of detected faults, sensor validation, automatic generation of schematic diagrams and automatic recovery from failures. This approach is more versatile and more powerful than the conventional hard coded approach and offers many advantages over it, although, for systems which require high speed reaction times or aren't well understood, knowledge based control and monitor systems may not be appropriate.

Cornell, Matthew↗

Testing of the Engineering Model Electrical Power Control Unit for the Fluids and Combustion Facility

The John H. Glenn Research Center at Lewis Field (GRC) in Cleveland, OH and the Sundstrand Corporation in Rockford, IL have designed and developed an Engineering Model (EM) Electrical Power Control Unit (EPCU) for the Fluids Combustion Facility, (FCF) experiments to be flown on the International Space Station (ISS). The EPCU will be used as the power interface to the ISS power distribution system for the FCF's space experiments'test and telemetry hardware. Furthermore. it is proposed to be the common power interface for all experiments. The EPCU is a three kilowatt 12OVdc-to-28Vdc converter utilizing three independent Power Converter Units (PCUs), each rated at 1kWe (36Adc @ 28Vdc) which are paralleled and synchronized. Each converter may be fed from one of two ISS power channels. The 28Vdc loads are connected to the EPCU output via 48 solid-state and current-limiting switches, rated at 4Adc each. These switches may be paralleled to supply any given load up to the 108Adc normal operational limit of the paralleled converters. The EPCU was designed in this manner to maximize allocated-power utilization. to shed loads autonomously, to provide fault tolerance. and to provide a flexible power converter and control module to meet various ISS load demands. Tests of the EPCU in the Power Systems Facility testbed at GRC reveal that the overall converted-power efficiency, is approximately 89% with a nominal-input voltage of 12OVdc and a total load in the range of 4O% to 110% rated 28Vdc load. (The PCUs alone have an efficiency of approximately 94.5%). Furthermore, the EM unit passed all flight-qualification level (and beyond) vibration tests, passed ISS EMI (conducted, radiated. and susceptibility) requirements. successfully operated for extended periods in a thermal/vacuum chamber, was integrated with a proto-flight experiment and passed all stability and functional requirements.

Kimnach, Greg L.↗

Toward biologically inspired self healing digital embedded devices: BIO-SymPle - 388

One of the more interesting concepts being postulated for next gen power plants, is the notion of highly resilient and survivable I and C systems. While resilience and survivability are 'cross system attributes', resilience and robustness will rely on highly robust and fault resilient devices as a foundation. This paper presents a new self-healing digital I and C architecture inspired by the operation of two biological concepts: human immune system and embryonic stem cells. The purpose of this research is look at different bio-inspired paradigms for organizing system functions so that they become inherently resilient due to device organization and behaviors. Our current proposed approach (called BIO-SymPle) is organized in two levels: critical service layer, which is providing the intended service of critical application, and healing layer, that supervises the operation of all repair mechanisms. To facilitate coordination, organized behavior among cells we employ network-based topology structures which is comprised of four active cells, four pre-generated redundant cells, and one embryonic stem cell. Collectively, the ensemble represents the building block that executes the local functionality based on the expression for DNA genetic codes stored inside each cell. The four bio-operational active cells are protected by their neighboring spare cells that imitate how white blood cells are distributed around the antigens in their locations. Ultimately, the proposed multi-layer architecture is able to cover a significant number of coincident faults and we believe architectures like BIO-SymPLe can positively impact the next generation digital I and C system. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Topology-Agnostic, Scalable, Self-Healing, and Cost-Aware Protection of Microgrids

Most microgrid protection schemes found in published literature suffer from a lack of generality in that they work well for the assumed topology, including type and placement of sources. Other generic protection schemes tend to be too complicated, too expensive, or both. To overcome these draw- backs, a topology-agnostic, scalable, and cost-aware protection based on fundamental principles that work in the presence of high penetration of inverter-based resources (IBRs) is developed and tested in this paper. Here, the protection system also implements stable automatic reconfiguration of the healthy sections of the system after clearance of fault, thus increasing resilience by self- healing. To achieve this ambitious goal, stable inverter models are developed that operate in unbalanced networks in grid-connected and islanded modes, even with 100% IBRs, share power without conflicting controls, and can ride through faults while limiting fault currents. The scheme is tested for primary and backup protection and reconfiguration on the IEEE 123-node feeder in grid-connected and islanded modes with 15 IBRs connected to the system.

42 ENGINEERING↗

A study of Schwarz converters for nuclear powered spacecraft

High power space systems which use low dc voltage, high current sources such as thermoelectric generators, will most likely require high voltage conversion for transmission purposes. This study considers the use of the Schwarz resonant converter for use as the basic building block to accomplish this low-to-high voltage conversion for either a dc or an ac spacecraft bus. The Schwarz converter has the important assets of both inherent fault tolerance and resonant operation; parallel operation in modular form is possible. A regulated dc spacecraft bus requires only a single stage converter while a constant frequency ac bus requires a cascaded Schwarz converter configuration. If the power system requires constant output power from the dc generator, then a second converter is required to route unneeded power to a ballast load.

Stuart, Thomas A.↗

A study of Schwarz converters for nuclear powered spacecraft

High power space systems which use low dc voltage, high current sources such as thermoelectric generators, will most likely require high voltage conversion for transmission purposes. This study considers the use of the Schwarz resonant converter for use as the basic building block to accomplish this low-to-high voltage conversion for either a dc or an ac spacecraft bus. The Schwarz converter has the important assets of both inherent fault tolerance and resonant operation; parallel operation in modular form is possible. A regulated dc spacecraft bus requires only a single stage converter while a constant frequency ac bus requires a cascaded Schwarz converter configuration. If the power system requires constant output power from the dc generator, then a second converter is required to route unneeded power to a ballast load.

Stuart, Thomas A.↗

Self-Correcting HVAC Controls: Algorithms for Sensors and Dampers in Air-Handling Units

This report documents the self-correction algorithms developed in the Self-Correcting Heating, Ventilating and Air-Conditioning (HVAC) Controls project funded jointly by the Bonneville Power Administration and the Building Technologies Program of the U.S. Department of Energy. The algorithms address faults for temperature sensors, humidity sensors, and dampers in air-handling units and correction of persistent manual overrides of automated control systems. All faults considered create energy waste when left uncorrected as is frequently the case in actual systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Polyamide 66 as a Cryogenic Dielectric

Improvements in superconductor and cryogenic technologies enable novel power apparatus, \eg, cables, transformers, fault current limiters, generators, \etc, with better device characteristics than their conventional counterparts. In these applications electrical insulation materials play an important role in system weight, footprint (size), and voltage level. The trend in the electrical insulation material selection has been to adapt or to employ conventional insulation materials to these new systems. However, at low temperatures, thermal contraction and loss of mechanical strength in many materials make them unsuitable for superconducting power applications. In this paper, a widely used commercial material was characterized as a potential cryogenic dielectric. The material is used in ``oven bag'' a heat-resistant polyamide (nylon) used in cooking (produced by Reynolds\textregistered, Richmond, VA, USA). It is first characterized by Fourier transform infrared and x-ray diffraction techniques and determined to be composed of polyamide 66 (PA66) polymer. Secondly the complex dielectric permittivity and dielectric breakdown strength of the PA66 films are investigated. The dielectric data are then compared with data reported in the literature. A comparison of dielectric strength with a widely used high-temperature superconductor electrical insulation material, polypropylene-laminated paper (PPLP\texttrademark\ a product of Sumitomo Electric Industries, Japan), is provided. It is observed that the statistical analysis of the PA66 films yields 1\% failure probability at $127\ \kilo\volt\milli\meter^{-1}$; this value is approximately $46\ \kilo\volt\milli\meter^{-1}$ higher than PPLP\texttrademark. It is concluded that PA66 may be a good candidate for cryogenic applications. Finally, a summary of dielectric properties of some of the commercial tape insulation materials and various polymers is also provided.

36 MATERIALS SCIENCE↗

Anomaly detection in PV systems using constrained low-rank and sparse decomposition

PV (photovoltaic) systems, also known as solar panel systems, play an essential role in the mitigation of greenhouse gas emissions and the promotion of renewable energy. Through the conversion of sunlight into usable energy, electricity is generated without emitting greenhouse gases and producing pollutants. Notwithstanding the evolutionary significance of PV systems, the occurrence of defects and anomalies in PV systems may result in diminished power output, consequently impeding the efficiency of the systems and potentially resulting in hazards in certain circumstances. Therefore, early detection of faults and anomalies in PV systems is imperative to guarantee the reliability, efficiency, and safety of the systems. In this article, we develop a signal decomposition for the purpose of anomaly detection in PV systems. The proposed methodology is grounded on the concept of low-rank and sparse decomposition, with consideration given to the signs of the decomposed low-rank and sparse components, as well as the smooth variations within and between periods in the mean signals. Through the implementation of Monte Carlo simulations, we showcase the efficacy of our proposed methodology in identifying anomalies of varying durations and magnitudes in PV systems. A case study is employed to validate the proposed methodology in detecting anomalies in real PV systems.

14 SOLAR ENERGY↗

Designing Scalable Distributed Memory Models: A Case Study

Supercomputers complexity continue to rapidly increase, requiring novel software solutions to aid in addressing the extreme abundance of parallelism, restrictive power constraints, and fault tolerance requirements. While industrial standards like MPI and OpenMP have undergone extensive efforts to prepare for future systems [1, 2], ne grain asynchronous runtimes have demonstrated an innate agility in extracting performance which is otherwise arduous to attain with current execution models

Landwehr, Joshua B.↗

System applications of the fault tolerant memory

Conventional memory technologies currently employed in aerospace applications contribute at least fifty percent to system unreliability (where the system includes CPU, I/O and memory). A fault tolerant memory performs both error correction and memory replacement at the bit plane level. To determine the effects of system design of using a fault tolerant memory in space applications, analysis was performed to determine tradeable hardware configurations that meet the reliability goals of each program. The candidate configurations, which included redundant elements of the computer system with both conventional and fault tolerant memories, were then traded in terms of selection criteria of cost, weight, volume, and power. These trade studies demonstrated that a fault tolerant memory provided significant advantages in terms of cost, weight, and volume. The memory selected for this analysis was a recently developed five fault tolerant memory.

Murphy, L. J.↗