Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power system stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Thermo-Mechanical Modeling and Evaluation of the Cracking Response of Additively Manufactured Monolithic SiC Lattice Structures Subjected to Laser Heating

Increasing operating temperatures of solar receivers is paramount to the efficiency of concentrated solar thermal (CST) and solar power (CSP) systems. Owing to its high temperature stability combined with excellent thermal and optical properties, SiC has been the material of choice for application in high-temperature solar receivers. The state-of-the-art SiC volumetric concentrating solar air receivers such as honeycomb design have been demonstrated in field tests to achieve exit air temperatures approaching 800oC. However, successful application of CST systems for decarbonization requires significant increase in temperature capability of SiC receiver technology. Supported by an award from the Solar Technology Office (SETO), US Department of Energy (DOE), GE Research in collaboration with Heliogen Holdings Inc, is engaged in the development of ultra-High Operating Temperature SiC-matrix Solar Thermal Air Receiver (HOTSSTAR) enabled by additive manufacturing. The program objective is to design and to demonstrate a techno-economically viable SiC air receiver technology to achieve exit air temperature of 1100oC for CST applications. This report summarizes the learnings of a computational study on additively manufactured SiC lattice structures subjected to laser heating. The results from this study aim to help guide the design of a SiC receiver through a better understanding of lattice structure geometric parameters and their implications on the cracking response of the structure. In the study, a heat flux was applied to the surface of a 2”-diameter cylindrical lattice structure to simulate a 4kW CO2 laser. The resulting temperature distribution was applied to a structural model to approximate the stress distribution within the lattice structure and a Weibull analysis was performed to gain insight into the probability of failure and to evaluate the cracking response of the structure. With this approach, the influence of lattice density on temperature, stress, and probability of failure was explored for two different lattice beam spacings. A discussion on modeling assumptions, a comparison with experimental results, and an evaluation of the lattice cracking response is provided.

14 SOLAR ENERGY↗

Evaluation of Thermal & Mechanical Properties of Additively Manufactured Monolithic SiC for Solar Receiver Applications

Increasing the operating temperatures of solar receivers is paramount to the efficiency of concentrated solar thermal (CST) and solar power (CSP) systems. Owing to its high temperature stability combined with excellent thermal and optical properties, SiC has been the material of choice for application in high-temperature solar receivers. State-of-the-art SiC volumetric concentrating solar air receivers such as the honeycomb design have successfully demonstrated in field exit air temperatures approaching 800oC. However, a successful application of CST systems for the decarbonization of heat reliant industrial sectors requires significant increases in the temperature capability of SiC receiver technology. Supported by an award from the Solar Technology Office (SETO), US Department of Energy (DOE), GE Research in collaboration with Heliogen Holdings Inc, is engaged in the development of an ultra-High Operating Temperature SiC-matrix Solar Thermal Air Receiver (HOTSSTAR) enabled by additive manufacturing. The program objective is to design and demonstrate a techno-economically viable SiC air receiver technology that can achieve exit air temperatures up to 1100oC for CST applications. We report and discuss the results of our testing and evaluation of thermal and mechanical properties of reaction-bonded SiC fabricated via binder jet printing to support the receiver component design, development, and analyses.

14 SOLAR ENERGY↗

Control of rotordynamic instability in a typical gas turbine's power system

The effect of rotor internal friction on the system's stability was studied when operated above the first critical speed. This internal friction is commonly caused by sliding press fits or sliding splines. Under conditions of high speed and low bearing damping, these systems will occassionally whirl at a frequency less than the shaft's rotational speed. This subsynchronous precession is a self excited phenomenon and stress reversals are created. This phenomenon was observed during engine testing. The reduction of spline friction and/or the inclusion of squeeze film damping have controlled the instability. Case history and the detail design of the squeeze film dampers is discussed.

Veikos, N. M.↗

Bio-regenerative life support

The basis for and the potential uses of bio-regenerative life support are examined. Bio-regenerative life support systems are an alternative to physical-chemical regeneration techniques for use when resupply of a crew in space is expensive, or when the logistics of resupply are difficult. Many of the scientific studies required for bio-regenerative life support systems have been completed and preliminary development of some components will begin within the next 12 to 18 months. The focus of the work that lies ahead will be efficient power and mass use, long-term system stability, component function, systems integration, and extensive testing in the space environment. Because of the advantages of bio-regeneration, it is anticipated that human life support for long-term space missions will evolve to include increasingly large amounts of biologically-based regeneration.

Macelroy, Robert D.↗

Rotating Unbalanced-Mass Devices for Scanning: Proof-of-Concept Test Results

This experiment proves the concept of line-of-sight scanning space-based and balloon-borne instruments and telescopes with rotating unbalanced-mss (RUM) devices. Extending the concept to free-flying spacecraft is straightforward. When line-of-sight scanning is required, but optical or electronic line-of-sight scanning is impossible, then scanning with RUM devices can offer huge power and mass savings, better system reliability and stability, and improved scan accuracy. This is especially true with large instruments and telescopes scanning at high frequencies.

Alhorn, Dean C.↗

Geoscience Laser Altimeter System (GLAS) Instrument: Flight Loop Heat Pipe (LHP) Acceptance Thermal Vacuum Test

Two loop heat pipes (LHPs) are to be used for tight thermal control of the Geoscience Laser Altimeter System (GLAS) instrument, planned for flight in late 2001. The LHPs are charged with Propylene as a working fluid. One LHP will be used to transport 110 W from a laser to a radiator, the other will transport 160 W from electronic boxes to a separate radiator. The application includes a large amount of thermal mass in each LHP system and low initial startup powers. The initial design had some non-ideal flight design compromises, resulted in a less than ideal charge level for this design concept with a symmetrical secondary wick. This less than ideal charge was identified as the source of inadequate performance of the flight LHPs during the flight thermal vacuum test in October of 2000. We modified the compensation chamber design, re-built and charged the LHPs for a final LHP acceptance thermal vacuum test. This test performed March of 2001 was 100% successful. This is the last testing to be performed on the LHPs prior to instrument thermal vacuum test. This sensitivity to charge level was shown through varying the charge on a Development Model Loop Heat Pipe (DM LHP) and evaluating performance at various fill levels. At lower fills similar to the original charge in the flight units, the same poor performance was observed. When the flight units were re-designed and filled to the levels similar to the initial successful DM LHP test, the flight units also successfully fulfilled all requirements. This final flight Acceptance test assessed performance with respect to startup, low power operation, conductance, and control heater power, and steady state control. The results of the testing showed that both LHPs operated within specification. Startup on one of the LHPs was better than the other LHP because of the starter heater placement and a difference in evaporator design. These differences resulted in a variation in the achieved superheat prior to startup. The LHP with the lower superheat was sensitive to the thermal environment around the compensation chamber, while the LHP with the higher superheat (similar in design to DM LHP) was not. In response to the test results the placement of the starter heater will be optimized for the flight instrument testing for higher achieved superheat. This presentation discusses startup behavior, overall conductance of a radiator system, low power operation, high power operation, temperature control stability, and control heater power requirements as measured during this acceptance thermal vacuum test. A brief summary of 'lessons learned' will be included.

Baker, Charles↗

Online Tracking of Two Dominant Inter-Area Modes of Oscillation in the Eastern Interconnection

Reliable power system operation requires that small-signal stability be maintained at all times. Mode meters are measurement-based tools that provide operators with situational awareness of the system's stability margin. They operate by continually tracking the inter-area modes of oscillation that govern small-signal stability. This paper reports on the deployment of mode meters for online monitoring of two dominant modes of oscillation in the United States' Eastern Interconnection (EI). The use of measurements from system operators across the interconnection to provide continuous tracking is novel in the EI. Results from over four months of analysis reveal diurnal patterns in the modes and demonstrate that they can be tracked through a variety of system conditions. The results from this study continue to build an understanding of the EI's modes that will inform future modeling and monitoring efforts.

Follum, James D.↗

A balloon-borne high-resolution spectrometer for observations of gamma-ray emission from solar flares

The design, development, and balloon-flight verification of a payload for observations of gamma-ray emission from solar flares are reported. The payload incorporates a high-purity germanium semiconductor detector, standard NIM and CAMAC electronics modules, a thermally stabilized pressure housing, and regulated battery power supplies. The flight system is supported on the ground with interactive data-handling equipment comprised of similar electronics hardware. The modularity and flexibility of the payload, together with the resolution and stability obtained throughout a 30-hour flight, make it readily adaptable for high-sensitivity, long-duration balloon fight applications.

Crannell, C. J.↗

Unstructured mesh-based multi-physics reactor transient simulation with iMC code

In this study, we present a time-dependent Monte Carlo simulation result about a complex fuel-loaded light water reactor system with thermal-hydraulic feedback using the KAIST iMC code. The intra-pin temperature distribution is calculated based on Monte Carlo-tallied detailed power distribution and the finite element heat transfer method. The temperature effect of fuel, absorber, and coolant are adequately reflected into the dynamic response by the on-the-fly Doppler broadened cross-section correction. For the time-dependent Monte Carlo transport simulation, the predictor-corrector quasi-static Monte Carlo method is used for this study. We tested the coupled analysis framework with a 17-by-17 fuel assembly loaded with the centrally-shielded burnable absorber (CSBA) fuel element. The temperature feedback effect on the material cross-section and the moderator density incurred negative reactivity in response to the external positive reactivity insertion, showing the inherent stability of the reactor system. The pin-wise power and temperature change during the system transient are presented and discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Effects of Phasor Measurement Uncertainty on Power Line Outage Detection

Phasor measurement unit (PMU) technology provides an effective tool to enhance the wide-area monitoring systems (WAMSs) in power grids. Although extensive studies have been conducted to develop several PMU applications in power systems (e.g., state estimation, oscillation detection and control, voltage stability analysis, and line outage detection), the uncertainty aspects of PMUs have not been adequately investigated. This paper focuses on quantifying the impact of PMU uncertainty on power line outage detection and identification, in which a limited number of PMUs installed at a subset of buses are utilized to detect and identify the line outage events. Specifically, the line outage detection problem is formulated as a multi-hypothesis test, and a general Bayesian criterion is used for the detection procedure, in which the PMU uncertainty is analytically characterized. We further apply the minimum detection error criterion for the multi-hypothesis test and derive the expected detection error probability in terms of PMU uncertainty. The framework proposed provides fundamental guidance for quantifying the effects of PMU uncertainty on power line outage detection. Case studies are provided to validate our analysis and show how PMU uncertainty influences power line outage detection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A State-Space Model for Stability Boundary Analysis of Grid-Following Voltage Source Converters Considering Grid Conditions

With the growing significance of renewable energy resources and energy storage systems, the number of grid-connected inverters has been rising at an increasingly rapid pace. Generally, these inverters are directly integrated with the distribution network by synchronizing with the grid voltage at the point of common coupling. However, the low grid strength and varying R/X ratios, as the common characteristics of most distribution networks or weak grids, can lead to dynamic interactions that comprise stability and limit the power transfer capacity of grid-connected inverters. To ensure stable operation of the inverters, researchers must determine the stability boundary, described as the maximum power transfer capacity of grid-connected inverters under the premise of maintaining system small-signal stability. For this purpose, we propose to formulate a state-space model of the system in the synchronously rotating dq-frame of reference and perform eigenvalue analysis to determine the stability boundary. With a detailed model of the control structure and parameters of the grid-connected inverters, the stability boundary is identified as a surface with respect to different grid strengths and R/X ratios. Case study results of proposed eigenvalue analysis are compared with those of admittance model-based stability analysis as well as time-domain simulation using a switching model in Matlab/Simulink, validating the effectiveness and accuracy of the proposed eigenvalue analysis for stability boundary identification.

grid-connected inverters↗

Gain Stability Measurements at S-band and X-band

The Search for Extraterrestrial Intelligence (SETI) requires low noise broadband total power radiometers of high gain stability. Preliminary results of SETI field tests for a variety of receiver configurations at Deep Space Station 13 are discussed. The power spectra of Deep Space Network low noise receiving systems exhibit I/F noise whose spectral index is significantly smaller than unity. The gain stability of the S-band systems tested is almost 0.0001. An appendix presents a derivation of the power spectrum of the output of a square law detector.

Gulkis, S.↗

Shunt-Connected FACTS and Synchronous Condensers

In recent years, the electric-transmission system has undergone a significant transformation marked by a greater integration of renewable-energy sources like wind and solar, the phasing out of thermal generation plants, and a concerted effort towards electrifying energy consumption. To keep pace with the integration of renewable-energy sources and the escalating demands of industries and households, it is imperative to expand and modernize the existing power infrastructure. These upgrades are essential to maintain grid stability, enhance power delivery, and boost overall efficiency of the system. However, challenges have emerged with the growing complexity of power grids, particularly in the realms of voltage control, transient stability, and power-quality management.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Advancing our understanding of instabilities in high-energy-density systems through the study of benchmark datasets with advanced modeling tools

Numerous types of pulsed power driven inertial confinement fusion (ICF) and high energy density (HED) systems rely on implosion stability to achieve desired temperatures, pressures, and densities. Sandia National Laboratories Pulsed Power Sciences Center’s main ICF platform, Magnetized Liner Inertial Fusion (MagLIF), suffers from implosion instabilities which limit attainable fuel conditions and can compromise fuel confinement. This Truman Fellowship research primarily focused on computationally exploring (a) methods for improving our understanding of hydrodynamic and magnetohydrodynamic instabilities that form during cylindrical liner implosions, (b) methods for mitigating implosion instabilities, particularly those that degrade performance of MagLIF targets, and (c) novel MagLIF target designs intended to improve target performance primarily via enhanced implosion stability. Several multi-dimensional computational tools were used, including the magnetohydrodynamics code ALEGRA, the radiation-magnetohydrodynamics code HYDRA, and the magnetohydrodynamics code KRAKEN. This research succeeded in executing and analyzing simulations of automagnetizing liner implosions, shockless MagLIF implosions, dynamic screw pinch driven cylindrical liner implosions, and cylindrically convergent HED instability studies. The methods and tools explored and developed in this Truman Fellowship research have been published in several peer-reviewed journal articles and will serve as useful contributions to the fields of pulsed power science and engineering, particularly pertaining to pulsed power ICF and HED science.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

HVDC Macrogrid Modeling for Power-flow and Transient Stability Studies in North American Continental-Level Interconnections

High Voltage Direct Current (HVDC) transmission lines are being constructed throughout the world, aided by advancements in power electronics and the potential value to transfer power between distant areas and off-shore locations. Multiple HVDC lines within and across large AC interconnections could bring about economic benefits such as interregional capacity exchange, and transfer of low-cost, distant electric energy directly to load centers. In addition, network configuration of HVDC lines could result in additional benefits that have not been deeply studied. This paper describes the modeling process for continental-level power system interconnections with the addition of multiple HVDC lines configured as a macrogrid. The models used for study are based on industry-accepted power-flow and dynamic system models for the North American Eastern and Western Interconnections. The model provides insight on feasibility and initial steady-state and stability tests of the HVDC macrogrid and its interactions with the existing electricity infrastructure, opening the door to analysis of the technical value of such a macrogrid.

HVDC transmission, North American Power Grids, AC ↗

Reliability Effects of Surge Current Testing of Solid Tantalum Capacitors

Solid tantalum capacitors are widely used in space applications to filter low-frequency ripple currents in power supply circuits and stabilize DC voltages in the system. Tantalum capacitors manufactured per military specifications (MIL-PRF-55365) are established reliability components and have less than 0.001% of failures per 1000 hours (the failure rate is less than 10 FIT) for grades D or S, thus positioning these parts among electronic components with the highest reliability characteristics. Still, failures of tantalum capacitors do happen and when it occurs it might have catastrophic consequences for the system. This is due to a short-circuit failure mode, which might be damaging to a power supply, and also to the capability of tantalum capacitors with manganese cathodes to self-ignite when a failure occurs in low-impedance applications. During such a failure, a substantial amount of energy is released by exothermic reaction of the tantalum pellet with oxygen generated by the overheated manganese oxide cathode, resulting not only in destruction of the part, but also in damage of the board and surrounding components. A specific feature of tantalum capacitors, compared to ceramic parts, is a relatively large value of capacitance, which in contemporary low-size chip capacitors reaches dozens and hundreds of microfarads. This might result in so-called surge current or turn-on failures in the parts when the board is first powered up. Such a failure, which is considered as the most prevalent type of failures in tantalum capacitors [I], is due to fast changes of the voltage in the circuit, dV/dt, producing high surge current spikes, I(sub sp) = Cx(dV/dt), when current in the circuit is unrestricted. These spikes can reach hundreds of amperes and cause catastrophic failures in the system. The mechanism of surge current failures has not been understood completely yet, and different hypotheses were discussed in relevant literature. These include a sustained scintillation breakdown model [1-3]; electrical oscillations in circuits with a relatively high inductance [4-6]; local overheating of the cathode [5,7, 8]; mechanical damage to tantalum pentoxide dielectric caused by the impact of MnO2 crystals [2,9, 10]; or stress-induced-generation of electron traps caused by electromagnetic forces developed during current spikes [11]. A commonly accepted explanation of the surge current failures is that at unlimited current supply during surge current conditions, the self-healing mechanism in tantalum capacitors does not work, and what would be a minor scintillation spike if the current were limited, becomes a catastrophic failure of the part [l, 12]. However, our data show that the scintillation breakdown voltages are significantly greater that the surge current breakdown voltages, so it is still not clear why the part, which has no scintillations, would fail at the same voltage during surge current testing (SCT).

Teverovsky, Alexander↗

Six degree of freedom fine motion positioning stage based on magnetic levitation

The design of a magnetically suspended six degree of freedom positioning system capable of nanometer positioning is presented. The sample holder is controlled in six degrees of freedom (DOF) over 300 micrometers of travel in the X, Y, and Z directions. A design and control summary and test results indicating stability and power dissipation are included in the paper. The system is vacuum compatible, uses commercially available materials, and requires minimal assembly and setup.

Arling, R. W.↗

Airworthiness criteria development for powered-lift aircraft: A program summary

A four-year simulation program to develop airworthiness criteria for powered-lift aircraft is summarized. All flight phases affected by use of powered lift (approach, landing, takeoff) are treated with regard to airworthiness problem areas (limiting flight conditions and safety margins: stability, control, and performance; and systems failure). The general features of powered-lift aircraft are compared to conventional aircraft.

Heffley, R. K.↗