Search NASA⌕ Search

SEARCH · Search NASA

Results for “Profiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Modification of divertor heat and article flux profiles with applied 3D fields in NSTX H-mode plasmas

Externally imposed non-axisymmetric magnetic perurbations are observed to alter divertor heat and particle flux profiles in the National Spherical Torus Experiment (NSTX). The divertor profiles are foud to have a modust level of multiple local peaks, characteristic of strike poimt splitting or the "magnetis lob" structure, even before the application of the 3D fields in some (but not all) NSTX discharges. This is thought to be due to the intrinsic error fields. The applied 3D fields augmented the intrinsic strike point splitting, making the ampliture of local peaks, and valleys larger in the divertor profile and striations at the divertor surface brighter. The measured heat flux profile shows that the radial location and spacing of the strations are qualitativel consistent witth a vacuum field tracing calcultion. 3D field application did not change the peak divertor heat and particle fluxes at the toroidal location of measurement. Spatial characteristics of the observed patterns are also reported in the paper.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermodynamic and liquid profiling during the 2010 Winter Olympics

Tropospheric observations by a microwave profiling radiometer and six-hour radiosondes were obtained during the Alpine Venue of the 2010 Winter Olympic Games at Whistler, British Columbia, by Environment Canada. The radiometer provided continuous temperature, humidity and liquid (water) profiles during all weather conditions including rain, sleet and snow. Gridded analysis was provided by the U.S. National Oceanic and Atmospheric Administration. We compare more than two weeks of radiometer neural network and radiosonde temperature and humidity soundings including clear and precipitating conditions. Corresponding radiometer liquid and radiosonde wind soundings are shown. Close correlation is evident between radiometer and radiosonde temperature and humidity profiles up to 10 km height and among southwest winds, liquid water and upper level thermodynamics, consistent with up-valley advection and condensation of moist maritime air. We compare brightness temperatures observed by the radiometer and forward-modeled from radiosonde and gridded analysis. Radiosonde-equivalent observation accuracy is demonstrated for radiometer neural network temperature and humidity retrievals up to 800 m height and for variational retrievals that combine radiometer and gridded analysis up to 10 km height

54 ENVIRONMENTAL SCIENCES↗

Laser wire beam profile monitor in the Spallation Neutron Source (SNS) superconducting linac

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory is an accelerator based neutron scattering facility. The SNS uses the large scale high energy superconducting linac (SCL) to provide high beam power utilizing hydrogen ion (H-) beams. For the diagnostics of high-brightness H- beam in the SCL, nonintrusive methods have to be developed. This paper describes design, implementation, theoretical analysis and experimental demonstration of a nonintrusive profile monitor system based on photodetachment, also known as laser wire, installed in the SNS-SCL. The SNS laser wire system is the largest of its kind with a capability of measuring both horizontal and vertical profiles of an operational H- beam at each of the 23 cryomodule stations along the SCL beam line by employing a single light source. Presently 9 laser wire stations have been commissioned which measures H- beam profiles at 9 different locations corresponding to energy levels of 200 MeV to 1 GeV. The laser wire diagnostics has no moving parts inside the beam pipe, causes no contamination on the superconducting surface, and can be run parasitically on an operational neutron production H- beam.

43 PARTICLE ACCELERATORS↗

CROCUS Sodar Measurements of Lower Atmospheric Wind Profiles at Argonne Testbed for Multiscale Observational Science (ATMOS) Site

The Scintec MFAS Sodar (Multiple-Frequency Acoustic Sounder) is an autonomous, ground-based acoustic remote sensing system designed to measure vertical profiles of horizontal wind speed, wind direction, and vertical velocity in the lower atmosphere. The instrument transmits sequences of acoustic pulses and detects the Doppler-shifted sound waves backscattered by small-scale temperature and velocity fluctuations caused by atmospheric turbulence. From these Doppler shifts, the system derives three-dimensional wind vectors by combining radial velocities from multiple beam orientations.The MFAS Sodar operates with a first usable range gate beginning at approximately 30 m above ground level and a configurable vertical resolution of 10 m. Under favorable acoustic conditions, the system provides wind profiles extending up to 600 m above ground level. Measurements are processed into 15-minute averaged profiles containing wind speed, direction, vertical velocity, and diagnostic quantities such as signal-to-noise ratio and echo strength.This dataset was collected at the Argonne Testbed for Multiscale Observational Science (ATMOS) facility in Lemont, Illinois, as part of DOE's CROCUS Urban Integrated Field Laboratory (UIFL) initiative. The purpose of these observations is to characterize the vertical wind structure and boundary-layer evolution across the urban–suburban gradient of the greater Chicago region. In particular, these data are intended to improve understanding of how local meteorology, such as lake-breeze penetration, nocturnal jets, and daytime mixing, varies between the densely built urban core and the suburban periphery. The MFAS observations provide critical context for evaluating high-resolution model simulations and for integrating with complementary lidar, radar, and in-situ meteorological measurements within the broader CROCUS UIFL network.All data are archived in NetCDF (Network Common Data Form) format and include wind and diagnostic parameters. The files can be accessed and analyzed using standard software that supports NetCDF, such as Python (e.g., xarray, netCDF4), MATLAB, R (e.g., ncdf4, raster), or Panoply (NASA’s NetCDF visualization application).

54 ENVIRONMENTAL SCIENCES↗

The Convolutional Multiple Whole Profile (CMWP) Fitting Method, a Global Optimization Procedure for Microstructure Determination

The analysis of line broadening in X-ray and neutron diffraction patterns using profile functions constructed on the basis of well-established physical principles and TEM observations of lattice defects has proven to be a powerful tool for characterizing microstructures in crystalline materials. These principles are applied in the convolutional multiple-whole-profile (CMWP) procedure to determine dislocation densities, crystallite size, stacking fault and twin boundary densities, and intergranular strains. The different lattice defect contributions to line broadening are separated by considering the hkl dependence of strain anisotropy, planar defect broadening and peak shifts, and the defect dependent profile shapes. The Levenberg–Marquardt (LM) peak fitting procedure can be used successfully to determine crystal defect types and densities as long as the diffraction patterns are relatively simple. However, in more complicated cases like hexagonal materials or multiple-phase patterns, using the LM procedure alone may cause uncertainties. Here, we extended the CMWP procedure by including a Monte Carlo statistical method where the LM and a Monte Carlo algorithm were combined in an alternating manner. The updated CMWP procedure eliminated uncertainties and provided global optimized parameters of the microstructure in good correlation with electron microscopy methods.

36 MATERIALS SCIENCE↗

Optimal control of the electron temperature profile in DIII-D using machine learning surrogate models

The viability of the tokamak as a potential fusion reactor depends on the ability to keep the plasma in a stable regime while achieving temperatures, densities, and confinement times that are as high as possible. Tokamak scenario development attempts to find plasma regimes that achieve all of these conditions and are accessible with a given set of hardware constraints. This requires the ability to control plasma properties such as the normalized beta, the internal inductance, safety factor, rotation, etc. One property that has received less attention than some of the others, but is no less critical to achieving high performance, is the electron temperature (T e ) profile. In this work, Linear Quadratic Integral (LQI) control is used to develop a controller for the electron temperature profile in DIII-D. The controller is based on a linearized model derived from the transport equation that describes the evolution of the electron temperature, and includes contributions from the neural network surrogate models NubeamNet and MMMnet. Furthermore, the controller is tested in simulation using COTSIM, and is proven capable of tracking a target T e profile.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling the impact of radiation-enhanced diffusion on implanted ion profiles

We report that ion irradiations are a valuable research tool for exploring radiation effects in materials. However, it is well recognized that the implanted ions can artificially modify the radiation damage evolution, e.g., enhancing amorphization processes at low irradiation temperatures and suppressing void swelling at elevated temperatures. Therefore, the implanted ion region should be avoided for most studies of ion irradiated materials. Due to increased interest in high damage, high temperature ion irradiations studying radiation effects in materials for proposed high dose Generation IV fission and fusion energy applications, it is crucial to quantify the extent of diffusional broadening of the implanted ion profile for a variety of temperatures, irradiation fluxes, and sink strengths. The present study summarizes computational analyses of thermal and depth-dependent radiation enhanced difusion (RED) on diffusion broadening of the implanted ion profiles in Fe and Ni for a variety of irradiation conditions. For a low assumed RED coefficient (10 -20 -10 -19 m 2 /s and 10 -4 and 10 -3 peak dpa/s, respectively) or high flux, broadening of the as-implanted ion profile is very small and a suitable artifact-free midrange region for analysis exists for ion energies above 5-6 MeV at 100 peak dpa. At high RED coefficients (10 -19 -10 -18 m 2 /s and 10 -4 and 10 -3 peak dpa/s, respectively) broadening is much more significant, and no valid region for investigation exists below 6-8 MeV ion energies at any damage level >50 dpa. While increasing flux decreases irradiation time, it also increases the RED coefficient; these effects mostly offset except under recombination-dominant conditions. For typical high dose irradiation studies of void swelling that exceed ~100 displacement per atom (dpa), ion energies > 6-8 MeV must be employed in order to achieve suitable artifact-free midrange irradiation analysis regions, depending on the material system. Lastly, analysis of amorphization/precipitation require even higher energies (>10 MeV).

07 ISOTOPE AND RADIATION SOURCES↗

Synapse: Synthetic application profiler and emulator

Abstract Motivated by the need to emulate workload execution characteristics on high- performance and distributed heterogeneous resources, we introduce Synapse. Synapse is used as a proxy application (or "representative application") for real workloads, with the advantage that it can be tuned in different ways and dimensions, and also at levels of granularity that are not possible with real applications. Synapse has a platform-independent application profiler, and has the ability to emulate profiled workloads on a variety of resources. Experiments show that the automated profiling performed using Synapse captures an application's characteristics with high fidelity. The emulation of an application using Synapse can reproduce the application's execution behavior in the original run- time environment, and can also reproduce those behaviors on different run-time environments.

97 MATHEMATICS AND COMPUTING↗

Beam Profile Disturbances from Implantable Pacemakers or Implantable Cardioverter-Defibrillator Interactions

The medical community is advocating for progressive improvement in the design of implantable cardioverter-defibrillators and implantable pacemakers to accommodate elevations in dose limitation criteria. With advancement already made for magnetic resonance imaging compatibility in some, a greater need is present to inform the radiation oncologist and medical physicist regarding treatment planning beam profile changes when such devices are in the field of a therapeutic radiation beam. Treatment plan modeling was conducted to simulate effects induced by Medtronic, Inc.-manufactured devices on therapeutic radiation beams. As a continuation of grant-supported research, we show that radial and transverse open beam profiles of a medical accelerator were altered when compared with profiles resulting when implantable pacemakers and cardioverter-defibrillators are placed directly in the beam. Results are markedly different between the 2 devices in the axial plane and the sagittal planes. Vast differences are also presented for the therapeutic beams at 6-MV and 18-MV x-ray energies. Maximum changes in percentage depth dose are observed for the implantable cardioverter-defibrillator as 9.3% at 6 MV and 10.1% at 18 MV, with worst distance to agreement of isodose lines at 2.3 cm and 1.3 cm, respectively. For the implantable pacemaker, the maximum changes in percentage depth dose were observed as 10.7% at 6 MV and 6.9% at 18 MV, with worst distance to agreement of isodose lines at 2.5 cm and 1.9 cm, respectively. No differences were discernible for the defibrillation leads and the pacing lead.

61 RADIATION PROTECTION AND DOSIMETRY↗

Absolute density-profile tomography of molecular beams using multiphoton ionization

We describe an approach for the absolute density measurement of rotationally symmetric molecular beams via multiphoton ionization. This simple single-projection tomographic technique requires only knowledge of the spatial intensity profile and ionization characteristics of the focused laser beam that probes the pulsed molecular jet. Multiphoton ionization (MPI) of a xenon beam allowed tomographic reconstruction of a two-dimensional density profile with a peak density of (4.2{+-}0.4)x10{sup 18} m{sup -3}, which was compared with the theoretical predictions of the sudden freeze model. An analytic solution to the Abel transform is derived for Gaussian projected density profiles which greatly simplifies the reconstruction of the absolute radial density. MPI is sufficiently general that this technique can be readily applied to atomic beams with a broad range of chemistries.

74 ATOMIC AND MOLECULAR PHYSICS↗

Study of multilayer-reflected beam profiles and their coherence properties using beamlines ID19 (ESRF) and 32-ID (APS)

The use of multilayer mirrors is an interesting alternative for reflective X-ray monochromatization with respect to reflection from crystal optics. The increased photon flux density due to the multilayers' larger bandwidth is of crucial importance for, e.g, full-field X-ray imaging applications. Drawbacks are the introduced modifications of the reflected beam profile as well as a certain loss of coherence, summarized as wavefront degradation. Our recent work has shown that the modification of the beam profile can vary with, e.g., the material composition of the coating applied. In order to verify our findings, a beamline round-robin has been initiated, comparing the wavefront profiles after reflection by selected multilayers at beamlines 32-ID (Advanced Photon Source) and ID19 (European Synchrotron Radiation Facility) with our initial results acquired at BM05 (ESRF) [1].

43 PARTICLE ACCELERATORS↗

A real-time beam-profile monitor for a PET cyclotron

Beam profiles in medical cyclotrons are traditionally measured using techniques that do not provide any information about short-term fluctuations of the beam shape or beam intensity. To overcome this, we have developed a real-time harp beam profile monitor which can withstand beam power in excess of 300 W. The monitor and electronics were constructed and applied toward a 13 MeV proton beam with current of up to 25 {mu}A. Herein are reported preliminary beam-profile measurement results.

43 PARTICLE ACCELERATORS↗

Control of plasma profile in microwave discharges via inverse-problem approach

In the manufacturing process of semiconductors, plasma processing is an essential technology, and the plasma used in the process is required to be of high density, low temperature, large diameter, and high uniformity. This research focuses on the microwave-excited plasma that meets these needs, and the research target is a spatial profile control. Two novel techniques are introduced to control the uniformity; one is a segmented slot antenna that can change radial distribution of the radiated field during operation, and the other is a hyper simulator that can predict microwave power distribution necessary for a desired radial density profile. The control system including these techniques provides a method of controlling radial profiles of the microwave plasma via inverse-problem approach, and is investigated numerically and experimentally.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rapid measurement of charged particle beam profiles using a current flux grating

The principle and physics issues of charged particle beam diagnostics using a current flux grating are presented. Unidirectional array of conducting channels with interstitial insulating layers of spacing d is placed in the beam path to capture flux of charge and electronically reproduce an exact beam current profile with density variation. The role of secondary electrons due to the impinging particle beam (both electron and ion) on the probe is addressed and a correction factor is introduced. A 2-dimensional profile of the electron beam is obtained by rotating the probe about the beam axis. Finally, a comparison of measured beam profile with a Gaussian is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of the plasma profiles on photon and pair production in ultrahigh intensity laser solid interaction

The model of photon and pair production in strong field quantum electrodynamics is implemented into our 1D3V particle-in-cell code with Monte Carlo algorithm. Using this code, the evolution of the particles in ultrahigh intensity laser (∼10{sup 23} W/cm{sup 2}) interaction with aluminum foil target is observed. Four different initial plasma profiles are considered in the simulations. The effects of initial plasma profiles on photon and pair production, energy spectra, and energy evolution are analyzed. The results imply that one can set an optimal initial plasma profile to obtain the desired photon distributions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Beam profile and coherence properties of synchrotron beams after reflection on modified multilayer mirrors

Multilayer mirrors present an attractive alternative for reflective hard X-ray monochromators due to their increased bandwidth compared with crystal-based systems. An issue remains the strong modulations in the reflected beam profile, i.e. an irregular stripe pattern. This is a major problem for micro-imaging applications, where multilayer-based monochromators are frequently employed to deliver higher photon flux density. A subject of particular interest is how to overcome beam profile modifications, namely the stripe patterns, induced by the reflection on a multilayer. For multilayer coatings in general it is known that the substrate and its surface quality significantly influence the performance of such kind of mirrors as the coating reproduces to a certain degree roughness and shape of the substrate. Our studies have shown that modified coatings can significantly change the impact of the multilayer reflection on the beam profile. We will present recent results as well as a critical review.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Faraday-effect polarimetry for current profile measurement in the tokamak plasma edge

Toroidal current profile measurements in the tokamak plasma edge are critical for fusion plasma physics research and model validation. A three-wave Faraday-effect polarimeter-interferometer with a sub-centimeter spatial resolution is proposed on the DIII-D tokamak to determine the edge current profile via Abel inversion. By using probe beams with 316 µm wavelength, a low-field-side, vertical-view, single-pass optical layout covering the plasma edge region (R = 2.15–2.27 m) is assessed. Measurements with no greater than 0.1° polarimetric systematic uncertainty, no greater than 0.01° polarimetric root-mean-square noise (1 kHz bandwidth), and a 0.8 cm radial chord spacing are considered feasible based on the achieved performance of existing systems using similar wavelengths on fusion devices. Furthermore, synthetic diagnostic calculations taking various factors into account, such as diagnostic uncertainty and quality of magnetic flux surfaces, find that the edge current profile can be determined with up to 0.12 MA/m 2 uncertainty, or about 10% of the peak current density in the pedestal of an investigated high-confinement plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Runaway electron beam dynamics at low plasma density in DIII-D: energy distribution, current profile, and internal instability

Parameters of the post-disruption runaway electron (RE) beam in the collisionless background plasma achieved after deuterium injection are investigated in DIII-D. The spatially resolved RE energy distribution function is measured for the first time during the RE plateau stage by inverting hard X-ray bremsstrahlung spectra. It has maximum energy up to 20 MeV and a non-monotonous feature at 5{6 MeV observed only in the core of the beam supporting the possibility of kinetic instabilities. The RE current profile is reconstructed for the first time using the spatially resolved RE energy distribution. It is found to be more peaked than the pre-disruption plasma current, with higher internal inductance, suggesting preferential formation of REs in the core plasma or potentially a radially inward motion of the REs. The accessed relatively low-current (180 kA) RE beam is found stable, likely due to its elevated q profile. From this base stable equilibrium, instability is accessed by ramping the solenoid current. Under a large applied accelerating loop voltage an internal kink mode is observed. The kink mode leads to sawtooth-like relaxation of the RE current profile, but drives no RE loss. Under conditions of a large decelerating voltage, chirping Alfvénic instabilities driven by REs during the RE plateau stage are observed for the first time. The low-frequency (0.1{7 MHz) Alfvénic instabilities, supposedly compressional Alfvén eigenmodes, are found to be correlated with a RE loss signal. Finally, this provides novel plasma conditions to study these instabilities and investigate opportunities to utilize them for RE control. Bifurcated electron cyclotron emission (ECE) spectrum is measured during the collisionless RE plateau, with a break point at ≈100 GHz suggesting resonant absorption of the ECE at low frequencies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗