Search NASA⌕ Search

SEARCH · Search NASA

Results for “RELIABLE OPERATION PERFORMANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Transient Stability Study of a Real-World Microgrid with 100% Renewables

This paper performs a transient stability study of a real-world microgrid that can operate with 100% renewables to better understand the stability and reliability of the microgrid under various dynamic scenarios. In particular, the operation of multiple grid-forming (GFM) and grid-following (GFL) inverters in such a power system is not well understood under dynamic operation conditions, such as islanding and black start; therefore, in this paper, an electromagnetic transient model of the microgrid is developed to investigate the stability of the system under various dynamic operating conditions and to identify potential reliability risks. The PSCAD/EMTDC simulation with the high-fidelity model provides helpful insights into the optimal operation modes of GFM and GFL inverters as well as the stability and reliability of the microgrid. It can also inform field deployment in terms of inverter control parameters and coordination as well as the expected performance of black start and unplanned islanding.

black start↗

Performance of High Temperature Operational Amplifier, Type LM2904WH, under Extreme Temperatures

Operation of electronic parts and circuits under extreme temperatures is anticipated in NASA space exploration missions as well as terrestrial applications. Exposure of electronics to extreme temperatures and wide-range thermal swings greatly affects their performance via induced changes in the semiconductor material properties, packaging and interconnects, or due to incompatibility issues between interfaces that result from thermal expansion/contraction mismatch. Electronics that are designed to withstand operation and perform efficiently in extreme temperatures would mitigate risks for failure due to thermal stresses and, therefore, improve system reliability. In addition, they contribute to reducing system size and weight, simplifying its design, and reducing development cost through the elimination of otherwise required thermal control elements for proper ambient operation. A large DC voltage gain (100 dB) operational amplifier with a maximum junction temperature of 150 C was recently introduced by STMicroelectronics [1]. This LM2904WH chip comes in a plastic package and is designed specifically for automotive and industrial control systems. It operates from a single power supply over a wide range of voltages, and it consists of two independent, high gain, internally frequency compensated operational amplifiers. Table I shows some of the device manufacturer s specifications.

Patterson, Richard↗

Austin Sustainable and Holistic Integration of Energy Storage and Solar PV [Austin SHINES]. Final Report, Version 2

The Austin SHINES project and solution is a software management platform, for an electric grid with a high penetration of dispersed photovoltaic (PV) solar generation sites, which maintains the traditional power quality and reliability associated with grid service. This project developed and deployed the platform as a Distributed Energy Resource Management System (DERMS), engaging multiple advanced controls, to evaluate operation and optimization of a fleet of diverse DER assets, installed at several locations among Austin Energy’s customers and distribution system. The project also produced a methodology to create a replicable DERMS template, adaptable to other regions and market structures. Last, Austin SHINES aimed to demonstrate the solution’s methodology would enable the DER grid ecosystem to serve load at a technical cost (System Levelized Cost of Electricity, or System LCOE) of less than the U.S. Department of Energy SHINES program metric of $0.14/kWh, in a defined boundary, while enabling a high penetration of distributed PV. Research was categorized in 6 reports (Final Deliverables = FD) listed below, with titles and descriptions indicating which area of understanding was investigated: FD-1: System Levelized Cost of Electricity (System LCOE) Methodology The creation and use of the System LCOE to Serve Load metric that encompasses the holistic, system-level costs and benefits of all resources, and enables them to be evaluated based on their ability to support an efficient and low-cost integrated grid ecosystem. FD-2: Software Platform Product Description The creation of new DER control methodologies deployable within a utility-grade software platform that enable DER's to maximize their benefit within a grid, that is capable of serving load enabling a high penetration of distributed PV generation. FD-3: Optimal Design Methodology Optimal design methodologies for individual DER installations that enable utilities to determine the optimal combinations and sizing for individual DER sites. FD-4: Austin SHINES Ownership and Operation Models for DER System Performance A comparison of multiple DER aggregation and ownership methodologies including direct utility control, third-party aggregator, and autonomous. FD-5: Economic Modeling & Optimization A comparison of multiple DER technology mixes and configurations within the distribution system, providing insight into an optimal blend of technologies that best enable the distribution system to serve load at the lowest cost at high penetrations of solar. FD-6: Fielded Assets Deployed DER assets within the Austin Energy SHINES circuits. Austin SHINES provided an opening for state-of-the-art technology products to be deployed, providing a rich opportunity for improving how each of the products perform as stand-alone products, and in concert with other complementary products. The Austin SHINES project comprised of two key metrics for System LCOE: SystemLCOE_SHINES<$0.14/kWh Modeled ΔSystemLCOE_SHINES/ΔSystemLCOE_Base≥20% at same solar penetration The System LCOE calculation uses the costs of the utility-owned infrastructure as it exists today, the cost of the DERs that exist in the system today, and the cost of the purchase of energy from ERCOT wholesale markets over the course of the calendar year. All costs are on an annualized basis. The capital and operating costs are derived from the rate case, which produces a yearly cost. The net cost of energy and services imported to the system is integrated over the test year, as is the load served and solar penetration. The first metric was easily achieved by every scenario considered. The goal was set when the Department of Energy’s SHINES Funding Opportunity Announcement was written in 2015 and was a more difficult target at the time. Due mostly to rapidly declining costs for DERs and the significant decrease in the Electric Reliability Council of Texas (ERCOT) energy market prices, which results in lower net cost of energy purchases, the System LCOE is well below this target for all scenarios considered. A fleet of DERs can assume different mixtures, each of which serves the load at a different LCOE. The optimal mixture of DERs serves load at the smallest System LCOE. The second metric (hereinafter %delta metric) asks that the holistic DERMS controls reduce the incremental cost above the baseline of going to a high solar penetration future by at least 20% as compared to the case of a DER deployment with no sophisticated controls (autonomous). Many comparison sets were created throughout this project. Physical technology was installed for informing utility engineering and testing several types of operational control schemes, through the DERMS. The types of operational control which were compared for valuation of the System LCOE Metric were: Holistic control = using the full suite of the DERMS platform to decide and optimize how/why the systems operate depending on weather, market, and reliability signal input. Autonomous control = a local mode at the asset site, wherein a schedule operates the asset, with visibility into performance only No control = the baseline for comparing value against the other two types of control The types of ownership control included: Direct Utility control = the utility dispatches a signal to each asset Third-Party Aggregator = a third party aggregates a fleet of assets and the utility dispatches one signal for all Autonomous = a local mode is set for operation at the asset site, wherein a schedule operates the asset, with visibility into performance only The types of control methodologies deployable within a utility-grade software platform included: Utility Peak Load Reduction = Lower transmission cost obligation Day-Ahead Energy Arbitrage = Realize economic value through price differential Real-Time Price Dispatch = Realize economic value from real-time price spikes Voltage support = Reduce losses and increase solar generation Distribution Congestion Management = Increase local grid reliability Demand Charge Reduction = Lower customer bills and realize system benefit The fielded assets deployed for the project were: Utility Scale Kingsbery Energy Storage System: 1.5 MW / 3 MWh Li-Ion battery storage Mueller Energy Storage System: 1.75 MW / 3.2 MWh Li-Ion battery storage, 7 Energy Storage Units (250 kW each) La Loma Community Solar: 2.6 MW Commercial Scale Aggregated storage installations at 3 sites, with existing solar (300+ kW): One 18 kW / 36 kWh Li-Ion battery storage Two 72 kW / 144 kWh Li-Ion battery storage Residential Scale Aggregated storage installations: -Six stationary battery storage systems (10 kWh each) at homes with existing solar -One Electric Vehicle installed as Vehicle-to-Grid (V2G) Utility-Controlled Solar via Smart Inverters at 12 homes Autonomously-Controlled Smart Inverters at 6 homes Over the course of the project, Austin SHINES undertook installing more than 3 MW of distributed battery energy storage, smart PV inverters, a DER control platform, and other enabling technologies utilizing customer and utility locations and aggregation models. All of these resources were to be integrated and optimized at the utility level. DER assets and control methodologies were designed to achieve a credible pathway to a System LCOE for energy delivered to load of $0.14//kWh or less by 2020, while maximizing distributed solar generation and maintaining acceptable standards of power quality. The project also established a template for other regions to follow, to maximize the adoption of distributed solar PV in support of an economic and efficient grid. In total, the Austin SHINES project added value to the DER subject area in each layer of integration. From utility, to commercial to residential scales, the sheer hierarchy of communication and coordination was a significant accomplishment in addition to learnings from what these communications revealed was unique to each. Economically, the most effective method demonstrated was the criticality of planning phases. Contingencies and multiple projection scenarios helped guide the project to deploy optimal design as close as feasible, in real world conditions. The project and reports will serve public benefit by outlining specific areas of DER strategy and installation where many stakeholders and needs can be addressed with improved efficiency. Overall, communities and utilities should use the results to guide the increasing options available for powering the grid with DER, renewables, and carbon considerate energy.

14 SOLAR ENERGY↗

Data Reliability in BIM and Performance Analytics: A Survey of Contemporary AECO Practice

As awareness around building energy consumption increases, practitioners are encouraged to consider performance aspects regarding the built environment more closely and find ways to improve its efficiency. Improvements in building information modeling (BIM) and building performance simulation (BPS) tools present opportunities to facilitate information communication with a wider range of stakeholders. The building sector can benefit from the integration of performance informatics; however, there has been limited success in utilizing available technologies that promote data integration and management in favor of enriching our knowledge and understanding of buildings as artifacts of information. This phenomenon was investigated by conducting a survey, together with a review of relevant literature, to depict the relevant challenges and opportunities for the architecture, engineering, construction, and owner-operated (AECO) industry, as it undergoes digital transformation, as well as the working practices that have formed around them. It is argued that the current tools available to practitioners do not support effective data serialization between design and analytics processes, affecting the collaboration between team members. Lastly, a series of functional goals are proposed to support a higher level of reliability in the ways information is mobilized, by rethinking the technologies and methods for organizing information systems.

42 ENGINEERING↗

Electrical Energy Storage Data Submission Guidelines, Version 2

Energy storage technologies are positioned to play a substantial role in power delivery systems. They have the potential to serve as an effective new resource to maintain reliability and allow for increased penetration of renewable energy. However, because of their relative infancy, there is a lack of knowledge about how these resources truly operate over time. A data analysis can help ascertain the operational and performance characteristics of these emerging technologies. Rigorous testing and a data analysis are important for all stakeholders to ensure a safe, reliable system that performs predictably on a macro level. Standardizing testing and analysis approaches to verify the performance of energy storage devices, equipment, and systems when integrating them into the grid will improve the understanding and benefit of energy storage over time from technical and economic vantage points. Demonstrating the life-cycle value and capabilities of energy storage systems begins with the data that the provider supplies for the analysis. After a review of energy storage data received from several providers, some of these data have clearly shown to be inconsistent and incomplete, raising the question of their efficacy for a robust analysis. This report reviews and proposes general guidelines, such as sampling rates and data points, that providers must supply for a robust data analysis to take place. Consistent guidelines are the basis of a proper protocol and ensuing standards to (1) reduce the time that it takes for data to reach those who are providing the analysis; (2) allow them to better understand the energy storage installations; and (3) enable them to provide a high-quality analysis of the installations. The report is intended to serve as a starting point for what data points should be provided when monitoring. Readers are encouraged to use the guidance in the report to develop specifications for new systems, as well as enhance current efforts to ensure optimal storage performance. As battery technologies continue to advance and the industry expands, the report will be updated to remain current.

25 ENERGY STORAGE↗

Progress in High Power Density SOFC Material Development for Aerospace Applications

Solid oxide fuel cell (SOFC) systems for aircraft applications require order of magnitude increase in specific power density and long life under aircraft operating conditions. Advanced SOFC materials and fabrication processes are being developed at NASA GRC to increase specific power density and durability of SOFC cell and stack. Initial research efforts for increasing specific power density are directed toward increasing the operating temperature for the SOFC system and reducing the weight of the stack. While significant research is underway to develop anode supported SOFC system operating at temperatures in the range of 650 - 850 C for ground power generation applications, such temperatures may not yield the power densities required for aircraft applications. For electrode-supported cells, SOFC stacks with power densities greater than 1.0 W/sq cm are favorable at temperatures in excess of 900 C. The performance of various commercial and developmental anode supported cells is currently being evaluated in the temperature range of 900 to 1000 C to assess the performance gains and materials reliability. The results from these studies will be presented. Since metal interconnects developed for lower temperature operation are not practical at these high temperatures, advanced perovskite based ceramic interconnects with high electronic conductivity and lower sintering temperatures are being developed. Another option for increasing specific power density of SOFC stacks is to decrease the stack weight. Since the interconnect contributes to a significant portion of the stack weight, considerable weight benefits can be derived by decreasing its thickness. Eliminating the gas channels in the interconnect by engineering the pore structure in both anode and cathode can offer significant reduction in thickness of the ceramic interconnect material. New solid oxide fuel cells are being developed with porous engineered electrode supported structures with a 10 - 20 micron thin electrolyte. The performance data for advanced SOFC cells with engineered porosity in both electrodes will be presented.

Cable, Thomas L.↗

Advanced modulation technology development for earth station demodulator applications. Coded modulation system development

A jointly optimized coded modulation system is described which was designed, built, and tested by COMSAT Laboratories for NASA LeRC which provides a bandwidth efficiency of 2 bits/s/Hz at an information rate of 160 Mbit/s. A high speed rate 8/9 encoder with a Viterbi decoder and an Octal PSK modem are used to achieve this. The BER performance is approximately 1 dB from the theoretically calculated value for this system at a BER of 5 E-7 under nominal conditions. The system operates in burst mode for downlink applications and tests have demonstrated very little degradation in performance with frequency and level offset. Unique word miss rate measurements were conducted which demonstrate reliable acquisition at low values of Eb/No. Codec self tests have verified the performance of this subsystem in a stand alone mode. The codec is capable of operation at a 200 Mbit/s information rate as demonstrated using a codec test set which introduces noise digitally. The measured performance is within 0.2 dB of the computer simulated predictions. A gate array implementation of the most time critical element of the high speed Viterbi decoder was completed. This gate array add-compare-select chip significantly reduces the power consumption and improves the manufacturability of the decoder. This chip has general application in the implementation of high speed Viterbi decoders.

Miller, Susan P.↗

Recommended key performance indicators for operational management of wind turbines

Operational managers of wind turbines usually monitor a big fleet of turbines and thus need highly condensed information to identify underperforming turbines and to prioritize their work. Key performance indicators (KPIs) are a solid and frequently used tool for this purpose. However, the KPIs used in the wind industry are not unified to date, which makes comparison in the industry difficult. Further, comprehensive standards on a set of KPIs for the wind industry are missing. This article identifies and recommends KPIs and provides detailed definitions to make KPIs comparable and to enable benchmarking. The starting point of this work is an industry survey with 28 participants intended to identify commonly used KPIs, collect various possible definitions, and prioritize them. Out of a total of 50 KPIs, we discuss in a next step 33 selected KPIs on performance, maintenance, and reliability in detail and recommend definitions, most of which are based on international standards. As a result, operators can easily use these recommendations to base their system of KPIs. By using this unified set of KPIs, operators can be well-prepared to conduct industrywide comparisons and benchmarks. The survey and this article will also serve as a basis for committee work of the FGW e.V. to develop a corresponding technical guideline.

17 WIND ENERGY↗

Photoelectrode Durability in Two- versus Three-Electrode Configurations: Understanding the Impact of Circuit Configuration on Water-Splitting Stability

Device durability remains a significant challenge in photoelectrochemical (PEC) water splitting under ambient conditions. Yet, a lack of understanding of the test configuration and applied bias effects continue to hinder progress. In this study, we differentiate two-electrode (2E) and three-electrode (3E) configurations for evaluating PEC material durability, focusing particularly on their impacts on photoabsorber solid-state operating conditions. Our results underscore the fallacy of inferring 2E device stability from durability measurements performed solely in 3E configurations. Unmeasured and often misunderstood total circuit bias in 3E tests moderates material degradation, leading to the overestimation of photoelectrode stability compared to short-circuit operation. We demonstrate how the photoabsorber's operating voltage critically governs charge separation, surface stability, and degradation mechanisms during PEC operation. With these findings, we propose a standardized framework for conducting more reliable 3E durability experiments that simulate unassisted performance to help accelerate the development of robust, stable materials for solar-driven water splitting.

08 HYDROGEN↗

FPGA-based trigger system for the LUX dark matter experiment

LUX is a two-phase (liquid/gas) xenon time projection chamber designed to detect nuclear recoils resulting from interactions with dark matter particles. Signals from the detector are processed with an FPGA-based digital trigger system that analyzes the incoming data in real-time, with just a few microsecond latency. The system enables first pass selection of events of interest based on their pulse shape characteristics and 3D localization of the interactions. It has been shown to be >99% efficient in triggering on S2 signals induced by only few extracted liquid electrons. It is continuously and reliably operating since its full underground deployment in early 2013. This document is an overview of the systems capabilities, its inner workings, and its performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Human reliability analysis studies from simulator experiments using Bayesian inference

Probabilistic Safety Assessment (PSA) of complex facilities is performed to arrive at the risk posed by them. PSA also accounts for the contribution of the human errors towards the overall risk through Human Reliability Analysis (HRA) in terms of Human Error Probability (HEP). Human operators are part of the system and do not work in isolation. Their performance is influenced by the context in which the actions are performed. As a result, quantification of HEP requires operator performance data under the given context. Some good sources of operator performance data are plant‘s operation data, simulator data and expert judgement. The plant operation data pertaining to HRA is generally sparse. In this situation, a full scope plant simulator provides a good alternative for operator performance data generation. Many of the currently practiced HRA methods have been developed by combining the empirical evidence with expert judgement and contain a lot of uncertainty in their estimates. Bayesian inference is suitable for updating the prior HRA estimates with the simulator evidence to obtain the posterior HEP. Here, posterior HEP has been calculated for postulated accident scenarios in advanced reactor (first of its kind) at design stage, using plant simulator.

97 MATHEMATICS AND COMPUTING↗

COOLR: A New System for Dynamic Thermal-Aware Computing

Extreme-scale systems need to walk a fine line between the amount of cooling they receive and the thermal-induced performance and reliability degradation they can sustain. System managers are extremely motivated to battle cooling-energy cost: the largest line item in their total operating cost. On the other hand, pushing the nodes to peak performance in tightened cooling regimes places the burden on the dynamic thermal management (DTM) to protect the hardware. DTM schemes throttle performance to relieve heat accumulation within nodes when cooling cannot mitigate the problem. These interventions prevent fatal failures but introduce inevitable performance degradations and variations. Such variations can have drastic consequences on the performance of extreme-scale systems. Furthermore, distribution of heat across different system nodes depends not only on the amount of workload. Even if a strictly equal share of computational load is assigned to all nodes, there are physical attributes and topological features of each system that inherently cause uneven accumulation of heat. These can cause one subcomponent to trigger DTM prematurely and penalize the overall system. Our goal in this project is to create a holistic thermal-aware view of the system, capturing both inherent physical attributes and dynamic system state. We developed COOLR, a dynamic system with the ability to evaluate the interplay between management of computation, data, power dissipation, and thermal state. Thereby, COOLR will achieve higher overall performance at the same energy and cooling cost. First, we performed a systematic power and thermal modeling and of high performance computing architectures. Analytical and empirical techniques were blended to generate a light-weight thermal model of target systems. Second, we developed a thermal-aware OS and runtime system. Policies for managing resources and schedules for processes has been designed to co-optimize the thermal state and performance of the system. The main outcome of our proposed thermal-aware dynamic computing system are scheduling and allocation of processes and memory accesses leading to an appropriately “skewed” distribution of activity across the system. The ultimate result of this new arrangement resulted in reduced occurrences of hotspots and reduced episodes of DTM intervention, leading to improvements in performance. The overall thermal characterization and modeling methodology (thermal instrumentation techniques, model building, and systematic model reduction) resulting from this project can be applied to systems beyond our immediate scope and will be applicable to future scaling. The thermal-aware dynamic computing paradigm will impact the efficiency of extreme-scale systems. The gained “thermal slack” can be given back to further tighten the cooling budget, benefiting the management cost of next generation extreme-scale systems.

97 MATHEMATICS AND COMPUTING↗

Impact of Latency and Reliability on Separation Assurance with Remotely Piloted Aircraft in Terminal Operations

Remotely Piloted Aircraft (RPA) for cargo operations in the national airspace system will impact safety due to, among other factors, the latency and reliability of command & control, and of communication. This paper investigates the safety impact with increasing mix of RPA amidst manned traffic in a generic arrival pattern with three merging flows. Latency was modelled as the response time between air traffic control's determination of a resolution and the RPAs' initiation of the maneuver. Reliability was modelled as a message drop probability. The experiment was repeated with two different aircraft types having different performance characteristics as representatives of RPA for conducting automated cargo operations. Overall response time above thirty seconds and message drop probability over twenty percent caused losses of separation. Specific results depended on the RPA aircraft type. The detailed impacts of latency and reliability with increasing mix of RPA traffic are provided. Applications of the approach for further studies at increasing levels of automation are also discussed.

Vishwanath Bulusu↗

Impact of Latency and Reliability on Separation Assurance with Remotely Piloted Aircraft in Terminal Operations

Remotely Piloted Aircraft (RPA) for cargo operations in the national airspace system will impact safety due to, among other factors, the latency and reliability of command & control, and of communication. This paper investigates the safety impact with increasing mix of RPA amidst manned traffic in a generic arrival pattern with three merging flows. Latency was modelled as the response time between air traffic control's determination of a resolution and the RPAs' initiation of the maneuver. Reliability was modelled as a message drop probability. The experiment was repeated with two different aircraft types having different performance characteristics as representatives of RPA for conducting automated cargo operations. Overall response time above thirty seconds and message drop probability over twenty percent caused losses of separation. Specific results depended on the RPA aircraft type. The detailed impacts of latency and reliability with increasing mix of RPA traffic are provided. Applications of the approach for further studies at increasing levels of automation are also discussed.

Vishwanath Bulusu↗

Real-Time Lifetime Prediction of Semiconductor Devices Using Hardware-in-the-Loop

This paper presents a unique approach to enable real-time lifespan prediction of semiconductor power modules using a Hardware-in-the-Loop (HIL) system. By integrating the module's overall loss characteristics-specifically switching and conduction losses-with a thermoelectric model of the thermal management system, this research demonstrates that the model can dynamically estimates the junction temperature profile of the semiconductor devices in response to a changing torque demand profile for the motor drive system. This capability enables continuous monitoring of the module's operational time and cumulative stress induced on the devices to compute accumulated remaining lifetime or time-to-failure (TTF). This study provides an architectural framework for the HIL system with high-fidelity component models of multiple physical domains, allowing simulation of dynamic behaviors of a closely-coupled motor drive system. The advanced real-time computation and measurement functionalities of the HIL system allow for both dynamic lifetime calculations based on simulated data and aggregate lifetime predictions utilizing historical data. Moreover, this paper details an algorithm that not only computes cumulative damage but also synthesizes these data into a comprehensive aggregated lifetime metric. This methodology can enhance the maintenance scheduling strategies and operational reliability of semiconductor devices in critical applications, ultimately extending their service life while optimizing performance.

hardware-in-the-loop (HIL)↗

An Innovative High Throughput Genome Releaser for Rapid and Efficient PCR Screening

High-throughput PCR screening is vital in synthetic biology and metabolic engineering as it allows researchers to rapidly analyze and detect numerous targeted genetic mutation in the genome. Current challenges for high-throughput PCR screening in synthetic biology include efficiently preparing genomic DNA, optimizing protocols for diverse sample types, managing contamination risks, and effectively analyzing the large volumes of data generated while ensuring consistent and accurate results. In this study, we present the development of a High Throughput Genome Releaser (HTGR), an innovative device addressing common challenges in screening PCR. This genome DNA releaser is designed based on a squash method for rapid, cost-effective, and efficient DNA release, optimized for subsequent PCR reactions. After experimenting with various synthetic materials, we selected a plastic that closely replicates the smooth surface and compression properties of microscope slides, ensuring reliable performance. We engineered a device featuring a 96-Well Plate and a shear applicator, operable both manually and automatically, and compatible with standard liquid-handling robot platform. This compatibility enhances ease of use in high-throughput PCR workflows. Additionally, we developed software to support its automatic functions. Our results demonstrated that the specially engineered 96-Well Plate and HTGR can effectively squash fungal spores , which release enough genome DNA for PCR screening. The genome releaser facilitates the preparation of PCR-amplifiable genomic DNA substrate from 96 samples within minutes, eliminates the need for extraction buffers, and is adaptable to a wide range of microorganisms and cells, which could significantly advance biomanufacturing processes.

Yuan, Guoliang [BATTELLE (PACIFIC NW LAB)]↗

Solar Refrigerator/Freezers For Vaccines

Report presents results of field tests of solar-cell-powered refrigerator/freezers for vaccines. Covers following topics: explanation of project; descriptions of refrigerator/freezer systems; account of installation experiences; performance data for 22 systems for which field-test data reported; summary of operational reliability; comments of users of some systems tested; and recommendations for design and future use. Photovoltaic systems store vaccines in remote regions where powerlines unavailable.

Ratajczak, Anthony F.↗