Search NASA⌕ Search

SEARCH · Search NASA

Results for “RISE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Hydronic Heating Retrofits for Low-Rise Multifamily Buildings: Boiler Control Replacement and Monitoring

The ARIES Collaborative, a U.S. Department of Energy Building America research team, partnered with NeighborWorks America affiliate Homeowners' Rehab Inc. of Cambridge, Massachusetts, to implement and study improvements to the central hydronic heating system in one of the nonprofit's housing developments. The heating control systems in the three-building, 42-unit Columbia Cambridge Alliance for Spanish Tenants housing development were upgraded.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Predicted Versus Actual Savings for a Low-Rise Multifamily Retrofit in Boulder, Colorado

To determine the most cost-effective methods of improving buildings, accurate analysis and prediction of the energy use of existing buildings is essential. However, multiple studies confirm that analysis methods tend to over-predict energy use in poorly insulated, leaky homes and thus, the savings associated with improving those homes. In NREL's report titled 'Assessing and Improving the Accuracy of Energy Analysis of Residential Buildings,' researchers propose a method for improving the accuracy of residential energy analysis methods. A key step in this process involves the comparisons of predicted versus metered energy use and savings. In support of this research need, CARB evaluated the retrofit of a multifamily building in Boulder, CO. The updated property is a 37 unit, 2 story apartment complex built in 1950, which underwent renovations in early 2009 to bring it into compliance with Boulder, CO's SmartRegs ordinance. Goals of the study were to: 1) evaluate predicted versus actual savings due to the improvements, 2) identify areas where the modeling assumptions may need to be changed, and 3) determine common changes made by renters that would negatively impact energy savings. In this study, CARB seeks to improve the accuracy of modeling software while assessing retrofit measures to specifically determine which are most effective for large multifamily complexes in the cold climate region. Other issues that were investigated include the effects of improving building efficiency on tenant comfort, the impact on tenant turnover rates, and the potential market barriers for this type of community scale project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydronic Heating Retrofits for Low-Rise Multifamily Buildings: Boiler Control Replacement and Monitoring

The ARIES Collaborative, a U.S. Department of Energy Building America research team, partnered with NeighborWorks America affiliate Homeowners' Rehab Inc. (HRI) of Cambridge, Massachusetts, to study improvements to the central hydronic heating system in one of the nonprofit's housing developments. The heating controls in the three-building, 42-unit Columbia Cambridge Alliance for Spanish Tenants housing development were upgraded. Fuel use in the development was excessive compared to similar properties. A poorly insulated thermal envelope contributed to high energy bills, but adding wall insulation was not cost-effective or practical. The more cost-effective option was improving heating system efficiency. Efficient operation of the heating system faced several obstacles, including inflexible boiler controls and failed thermostatic radiator valves. Boiler controls were replaced with systems that offer temperature setbacks and one that controls heat based on apartment temperature in addition to outdoor temperature. Utility bill analysis shows that post-retrofit weather-normalized heating energy use was reduced by 10%-31% (average of 19%). Indoor temperature cutoff reduced boiler runtime (and therefore heating fuel consumption) by 28% in the one building in which it was implemented. Nearly all savings were obtained during night which had a lower indoor temperature cut off (68 degrees F) than day (73 degrees F). This implies that the outdoor reset curve was appropriately adjusted for this building for daytime operation. Nighttime setback of heating system supply water temperature had no discernable impact on boiler runtime or gas bills.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydronic Heating Retrofits for Low-Rise Multifamily Buildings

The ARIES Collaborative, a Department of Energy Building America research team, partnered with NeighborWorks America affiliate Homeowners' Rehab Inc. (HRI) of Cambridge, MA to implement and study improvements to the heating system in one of the non-profit’s housing developments. The heating control systems in the 42-unit Columbia CAST housing development were upgraded in an effort projected to reduce heating costs by 15% to 25%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Predicted Versus Actual Savings for a Low-Rise Multifamily Retrofit in Boulder, Colorado

To determine the most cost-effective methods of improving buildings, accurate analysis and prediction of the energy use of existing buildings is essential. However, multiple studies confirm that analysis methods tend to over-predict energy use in poorly insulated, leaky homes and thus, the savings associated with improving those homes. In this project, the Building America CARB team evaluated the retrofit of a multifamily building in Boulder, CO. The updated property is a 37 unit, 2 story apartment complex built in 1950, which underwent renovations in early 2009 to bring it into compliance with Boulder, CO's SmartRegs ordinance. Goals of the study were to: 1) evaluate predicted versus actual savings due to the improvements, 2) identify areas where the modeling assumptions may need to be changed, and 3) determine common changes made by renters that would negatively impact energy savings. Other issues that were investigated include the effects of improving building efficiency on tenant comfort, the impact on tenant turnover rates, and the potential market barriers for this type of community scale project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydronic Heating Retrofits for Low-Rise Multifamily Buildings: Boiler Control Replacement and Monitoring

The ARIES Collaborative, a U.S. Department of Energy Building America research team, partnered with NeighborWorks America affiliate Homeowners' Rehab Inc. of Cambridge, Massachusetts, to implement and study improvements to the central hydronic heating system in one of the nonprofit's housing developments. The heating control systems in the three-building, 42-unit Columbia Cambridge Alliance for Spanish Tenants housing development were upgraded.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A close look at beam aborts with rise times less than 40 ms from the years 2014-2016. Case studies.

In an effort to understand the risks of operating RHIC with an additional delay of 40 ms in the abort system, all beam aborts triggered by loss monitors at store from the years 2014, 2015 and 2016 were analyzed; and particularly fast cases, selected. The results were presented at the RHIC retreat on Jul 29, 2016. All beam aborts at injection, during the ramp and at flattop but before the “ev-lumi” event were ignored since the additional delay of 40 ms is proposed for operation at store only. Many (but not all) of the 15 studied cases are of no concern. Cases with high damage potential are rare - but not rare enough. In order to make an added 40 ms during physics store conditions as safe as reasonably possible, additional permit inputs such as 10 Hz BF power supplies, RF storage cavities, power supply error states or BPMs, in addition to significantly reduced loss monitors (LM) thresholds for selected LM should be commissioned.

43 PARTICLE ACCELERATORS↗

The Rise in the Utilization of IoT Devices in Nuclear Facilities

The term Internet of Things (loT) encompasses everything connected to the internet, but it is increasingly being used to define objects that "talk" to each other. A broader term is that loT are the devices that connect to each other and to the internet. It has been mentioned that loT offers the potential for a "Forth industrial revolution" (1). This is primally because of the ease of use and quick link-up of devices within an area. This poses options for great interactivity but also create security concerns as many of these devices may not have been vetted for industrial use. By allowing for the intercommunication of these devices and combining with automated systems, we can now gather information, provide analysis and create automotive actions. This allows for faster response times as well as lowering the overall cost for operations in nuclear power facilities. (2)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Computational Fluid Dynamics Analysis of a 12 MW Circulating Fluidized Bed Rise

A three-dimensional (3D) two fluid model (TFM) model of the 12 MW circulating fluidized bed (CFB) riser at Chalmers University was developed using the open-source Multiphase Flow with Interphase eXchanges (MFiX) Software Suite. The hydrodynamic behavior of the riser was validated by comparing axial pressure profiles from experimental measurements with the results from the simulations. Under some of the operating conditions where there was no external circulation of solids, the pressure profiles from the simulation matched well with the experimental measurements. For the cases where there was external circulation of solids, the pressure profiles with the monodisperse solid phase modeling underpredicted the solids concentration in the freeboard region. With the inclusion of polydispersity in the model, the predicted pressure profiles agreed well with the experimental measurements. A two-dimensional (2D) model of the riser was used to perform simulations of coal combustion. The predicted flue gas outlet compositions of oxygen and carbon dioxide compared reasonably to experiments. The experiments also reported some concentration of carbon monoxide which was overpredicted in the simulations. Additional experimental data such as axial oxygen concentration profile and pressure profiles were also compared with the experiment. It was observed that the oxygen concentration in the bottom bed from the simulations was higher than in the experiments, which suggested that most of the oxidation reactions occurred in the bottom bed. The concentration of volatiles and char in the simulations was lower in the bottom bed than in the experiments, which suggest that there is not sufficient penetration of the solid phase species into the bed.

20 FOSSIL-FUELED POWER PLANTS↗

Peak Demand Limiting and Optimization of HVAC Systems for Common Areas in High-Rise Multi-Family Housing (CRADA 518)

This project aims to create an innovative energy saving solution that is affordable and easy to implement. Initially, the proposed solution will fulfill an existing need for HVAC systems that serve multi-family housing. However, the solution can be easily expanded to other markets such as large hospitals, hotels, and commercial buildings. The proposed solution will be creatively packaged so that it can work where peak demand charge is high or where goal is to conserve energy and reduce carbon footprint. Of course, both Peak Demand Limiting (PDL) and Set-point optimization (SPO) can also operate simultaneously.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Quick Rise and Fall of LK-99 as a Room Temperature Superconductor [Slides]

A swift determination of superconductivity vs non-superconductivity of LK-99 demonstrates the importance of reproducibility in science. This has benefited from 4 decades study of high-temperature cuprate mechanism. Holy grail of room-temperature ambient-pressure superconductor remains to be pursued. Caution is needed about DFT calculations. Crucial old experimental data should be referenced. With the existing amount of experimentally discovered superconductors, could data science make a stride?

36 MATERIALS SCIENCE↗

Novel subnanosecond rise, flattop, 100 kV high voltage pulse generator (ASAP-LDRD-22-0122)

We looked to build a new type of 100 kV pulse generator that we hope will avoid many of the problems seen with other commercially available pulse generators. We looked to exploit recent improvements in both lasers and solid-state pulse charge units along with an alternative triggering layout to build something new. For the pulse charging unit, we collaborated with Texas Tech to leverage their knowledge and expertise in pulse transformers and solid-state switching. The final result of the LDRD looks promising. Texas Tech was able to build a pulse charge unit that meets our specifications regarding output, and we were able to integrate it with a switch and a laser to create a device that meets the goals of the LDRD. There is still much work to do to advance the design further and improve reliability, but the proto-type design satisfies the goals we set for this LDRD.

42 ENGINEERING↗