Search NASA⌕ Search

SEARCH · Search NASA

Results for “Relative Motion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Self-consistent gravitational self-force

I review the problem of motion for small bodies in general relativity, with an emphasis on developing a self-consistent treatment of the gravitational self-force. An analysis of the various derivations extant in the literature leads me to formulate an asymptotic expansion in which the metric is expanded while a representative worldline is held fixed. I discuss the utility of this expansion for both exact point particles and asymptotically small bodies, contrasting it with a regular expansion in which both the metric and the worldline are expanded. Based on these preliminary analyses, I present a general method of deriving self-consistent equations of motion for arbitrarily structured (sufficiently compact) small bodies. My method utilizes two expansions: an inner expansion that keeps the size of the body fixed, and an outer expansion that lets the body shrink while holding its worldline fixed. By imposing the Lorenz gauge, I express the global solution to the Einstein equation in the outer expansion in terms of an integral over a worldtube of small radius surrounding the body. Appropriate boundary data on the tube are determined from a local-in-space expansion in a buffer region where both the inner and outer expansions are valid. This buffer-region expansion also results in an expression for the self-force in terms of irreducible pieces of the metric perturbation on the worldline. Based on the global solution, these pieces of the perturbation can be written in terms of a tail integral over the body's past history. This approach can be applied at any order to obtain a self-consistent approximation that is valid on long time scales, both near and far from the small body. I conclude by discussing possible extensions of my method and comparing it to alternative approaches.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In vivo verification of proton beam path by using post-treatment PET/CT imaging

Purpose: The purpose of this study is to establish the in vivo verification of proton beam path by using proton-activated positron emission distributions. Methods: A total of 50 PET/CT imaging studies were performed on ten prostate cancer patients immediately after daily proton therapy treatment through a single lateral portal. The PET/CT and planning CT were registered by matching the pelvic bones, and the beam path of delivered protons was defined in vivo by the positron emission distribution seen only within the pelvic bones, referred to as the PET-defined beam path. Because of the patient position correction at each fraction, the marker-defined beam path, determined by the centroid of implanted markers seen in the post-treatment (post-Tx) CT, is used for the planned beam path. The angular variation and discordance between the PET- and marker-defined paths were derived to investigate the intrafraction prostate motion. For studies with large discordance, the relative location between the centroid and pelvic bones seen in the post-Tx CT was examined. The PET/CT studies are categorized for distinguishing the prostate motion that occurred before or after beam delivery. The post-PET CT was acquired after PET imaging to investigate prostate motion due to physiological changes during the extended PET acquisition. Results: The less than 2 deg. of angular variation indicates that the patient roll was minimal within the immobilization device. Thirty of the 50 studies with small discordance, referred as good cases, show a consistent alignment between the field edges and the positron emission distributions from the entrance to the distal edge. For those good cases, average displacements are 0.6 and 1.3 mm along the anterior-posterior (D{sub AP}) and superior-inferior (D{sub SI}) directions, respectively, with 1.6 mm standard deviations in both directions. For the remaining 20 studies demonstrating a large discordance (more than 6 mm in either D{sub AP} or D{sub SI}), 13 studies, referred as motion-after-Tx cases, also show large misalignment between the field edge and the positron emission distribution in lipomatous tissues around the prostate. These motion-after-Tx cases correspond to patients with large changes in volume of rectal gas between the post-Tx and the post-PET CTs. The standard deviations for D{sub AP} and D{sub SI} are 5.0 and 3.0 mm, respectively, for these motion-after-Tx cases. The final seven studies, referred to as position-error cases, which had a large discordance but no misalignment, were found to have deviations of 4.6 and 3.6 mm in D{sub AP} and D{sub SI}, respectively. The position-error cases correspond to a large discrepancy on the relative location between the centroid and pelvic bones seen in post-Tx CT and recorded x-ray radiographs. Conclusions: Systematic analyses of proton-activated positron emission distributions provide patient-specific information on prostate motion ({sigma}{sub M}) and patient position variability ({Sigma}{sub p}) during daily proton beam delivery. The less than 2 mm of displacement variations in the good cases indicates that population-based values of {Sigma}{sub p} and {sigma}{sub M} used in margin algorithms for treatment planning at the authors' institution are valid for the majority of cases. However, a small fraction of PET/CT studies (approximately 14%) with {approx}4 mm displacement variations may require different margins. Such data are useful in establishing patient-specific planning target volume margins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Observation of Electromagnetic Transients in a Nb3Sn 4-layer Dipole Mirror Magnet

During testing of the Stress Managed Cosine-Theta dipole mirror magnet SMCTM1, magnet quenches were observed following large voltage spikes in the half-coil voltage taps which preceded normal quench initiation. Following some recent work at CERN measuring power current converter transients in relation to flux jumps, an additional differential current probe was added to the magnet instrumentation. Measurements of this probe, as well as the half coil voltage taps show a fast and substantial current change preceding the quench, hinting at coil motion. A simple model based on relative shift of the inner and outer layer coils was developed which suggests the magnitude of coil shift events is on the estimated relative coil shift from the magnet constraint conditions. The behavior is shown to be reversible and characteristic of stick-slip.

Krave, Steven [Fermilab] (ORCID:0000000217521457)↗

A motion-compensated scheme for helical cone-beam reconstruction in cardiac CT angiography

Since coronary heart disease is one of the main causes of death all over the world, cardiac computed tomography (CT) imaging is an application of very high interest in order to verify indications timely. Due to the cardiac motion, electrocardiogram (ECG) gating has to be implemented into the reconstruction of the measured projection data. However, the temporal and spatial resolution is limited due to the mechanical movement of the gantry and due to the fact that a finite angular span of projections has to be acquired for the reconstruction of each voxel. In this article, a motion-compensated reconstruction method for cardiac CT is described, which can be used to increase the signal-to-noise ratio or to suppress motion blurring. Alternatively, it can be translated into an improvement of the temporal and spatial resolution. It can be applied to the entire heart in common and to high contrast objects moving with the heart in particular, such as calcified plaques or devices like stents. The method is based on three subsequent steps: As a first step, the projection data acquired in low pitch helical acquisition mode together with the ECG are reconstructed at multiple phase points. As a second step, the motion-vector field is calculated from the reconstructed images in relation to the image in a reference phase. Finally, a motion-compensated reconstruction is carried out for the reference phase using those projections, which cover the cardiac phases for which the motion-vector field has been determined.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Estimation of full-field dynamic strains from digital video measurements of output-only beam structures by video motion processing and modal superposition

Strain is an necessary quantity to characterize local structural behaviors and directly correlates with structural damage initiation and development that is within local regions. Strain measurement at high spatial resolution (density) locations is thus required to characterize local structural behaviors and detect potential local damage. Traditional contact-type strain gauges are mostly discrete point-wise sensors that can only be placed in a limited number of positions. Distributed optical fiber sensing techniques can measure strains at spatially dense measurement points, but their instrumentation is a time- and labor-intensive process associated with the issue of the fragility of fibers. Noncontact optical measurement techniques, such as a family of interferometry techniques using laser beams (e.g., laser Doppler vibrometers), can provide vibration measurement at high density spatial points without the need to install sensors on the structure. Yet, these measurement devices are active sensing methods that are relatively expensive and vulnerable to ambient motion. Photogrammetry is an alternative noncontact optical measurement method using (passive) white-light imaging of digital video cameras that are relatively low-cost, agile, and provides simultaneous measurements at high spatial density locations where every pixel becomes a measurement point. Among others, digital image correlation can achieve full-field deformation measurements and subsequently estimate the full-field strains. However, it is computationally extensive. This research develops a new efficient approach to estimate the full-field (as many measurement points as the pixel number of the video frame on the structure) dynamic strains at high-spatial (pixel)-resolution/density location points from the digital video measurement of output-only vibrating structures. The developed approach is based on phase-based video motion estimation and modal superposition of structural dynamic response. Moreover, the method is augmented by a high-fidelity finite element model, which is updated with the full-field experimental modal parameters “blindly” identified from the video measurement of the output-only structure. Laboratory experiments are conducted to validate the method on a bench-scale cantilever beam structure. Results demonstrate that the full-field dynamic strain estimated by the developed approach from the video measurement of the output-only vibrating beam match very well those directly measured by the strain gauges (at discrete measurement points). Some factors associated with the effectiveness of the method are experimentally studied and discussed.

47 OTHER INSTRUMENTATION↗

Aseismic Motions Drive a Sparse Seismicity During Fluid Injections Into a Fractured Zone in a Carbonate Reservoir

An increase in fluid pressure in faults can trigger seismicity and large aseismic motions. Understanding how fluid and faults interact is an essential goal for seismic hazard and reservoir monitoring, but this key relation remains unclear. We developed an in situ experiment of fluid injections at a 10 meter scale. Water was injected at high pressure in different geological structures inside a fault damaged zone, in limestone at 280 m depth in the Low Noise Underground Laboratory (France). Induced seismicity, as well as strains, pressure, and flow rate, was continuously monitored during the injections. Although nonreversible deformations related to fracture reactivations were observed for all injections, only a few tests generated seismicity. Events are characterized by a 0.5-to-4 kHz content and a small magnitude (approximately -3.5). They are located within 1.5 m accuracy between 1 and 12 m from the injections. Comparing strain measurements and seismicity shows that more than 96% of the deformation is aseismic. The seismic moment is also small compared to the one expected from the injected volume. Moreover, a dual seismic behavior is observed as (1) the spatiotemporal distribution of some cluster of events is clearly independent from the fluid diffusion (2) while a diffusion-type pattern can be observed for some others clusters. Furthermore, the seismicity might therefore appear as an indirect effect to the fluid pressure, driven by aseismic motion and related stress perturbation transferred through failure.

58 GEOSCIENCES↗

STELLAR PROPER MOTION AND THE TIMING OF PLANETARY TRANSITS

Duration and period of transits in extrasolar planetary systems can exhibit long-term variations for a variety of reasons. Here we investigate how systemic proper motion, which steadily re-orients planetary orbit with respect to our line of sight, affects the timing of transits. We find that in a typical system with a period of several days, proper motion at the level of 100 mas yr{sup -1} makes transit duration vary at a rate {approx}10-100 ms yr{sup -1}. In some isolated systems this variation is at the measurable level (can be as high as 0.6 s yr{sup -1} for GJ436) and may exceed all other transit-timing contributions (due to the general relativity, stellar quadrupole, etc.). In addition, proper motion causes evolution of the observed period between transits P {sub obs} via the Shklovskii effect at a rate {approx}>10 {mu}s yr{sup -1} for the nearby transiting systems (0.26 ms yr{sup -1} in GJ436), which in some cases exceeds all other contributions to P-dot{sub obs}. Earth's motion around the Sun gives rise to additional periodic timing signal (even for systems with zero intrinsic proper motion) allowing a full determination of the spatial orientation of the planetary orbit. Unlike most other timing effects, the proper motion signatures persist even in systems with zero eccentricity and get stronger as the planetary period increases. They should be the dominant cause of transit-timing variations in isolated wide-separation (periods of months) systems that will be sought by Kepler.

99 GENERAL AND MISCELLANEOUS↗

A Novel Approach to Postmastectomy Radiation Therapy Using Scanned Proton Beams

Purpose: Postmastectomy radiation therapy (PMRT), currently offered at Massachusetts General Hospital, uses proton pencil beam scanning (PBS) with intensity modulation, achieving complete target coverage of the chest wall and all nodal regions and reduced dose to the cardiac structures. This work presents the current methodology for such treatment and the ongoing effort for its improvements. Methods and Materials: A single PBS field is optimized to ensure appropriate target coverage and heart/lung sparing, using an in–house-developed proton planning system with the capability of multicriteria optimization. The dose to the chest wall skin is controlled as a separate objective in the optimization. Surface imaging is used for setup because it is a suitable surrogate for superficial target volumes. In order to minimize the effect of beam range uncertainties, the relative proton stopping power ratio of the material in breast implants was determined through separate measurements. Phantom measurements were also made to validate the accuracy of skin dose calculation in the treatment planning system. Additionally, the treatment planning robustness was evaluated relative to setup perturbations and patient breathing motion. Results: PBS PMRT planning resulted in appropriate target coverage and organ sparing, comparable to treatments by passive scattering (PS) beams but much improved in nodal coverage and cardiac sparing compared to conventional treatments by photon/electron beams. The overall treatment time was much shorter than PS and also shorter than conventional photon/electron treatment. The accuracy of the skin dose calculation by the planning system was within ±2%. The treatment was shown to be adequately robust relative to both setup uncertainties and patient breathing motion, resulting in clinically satisfying dose distributions. Conclusions: More than 25 PMRT patients have been successfully treated at Massachusetts General Hospital by using single-PBS fields. The methodology and robustness of both the setup and the treatment have been discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

THE PPMXL CATALOG OF POSITIONS AND PROPER MOTIONS ON THE ICRS. COMBINING USNO-B1.0 AND THE TWO MICRON ALL SKY SURVEY (2MASS)

USNO-B1.0 and the Two Micron All Sky Survey (2MASS) are the most widely used all-sky surveys. However, 2MASS has no proper motions at all, and USNO-B1.0 published only relative, not absolute (i.e., on the International Celestial Reference Frame (ICRS), proper motions. We performed a new determination of mean positions and proper motions on the ICRS system by combining USNO-B1.0 and 2MASS astrometry. This catalog is called PPMXL (VO access to the catalog is possible via http://vo.uni-hd.de/ppmxl), and it aims to be completed from the brightest stars down to about V {approx} 20 all sky. PPMXL contains about 900 million objects, some 410 million with 2MASS photometry, and is the largest collection of ICRS proper motions at present. As representative for the ICRS, we chose PPMX. The recently released UCAC3 could not be used because we found plate-dependent distortions in its proper motion system north of -20{sup 0} declination. UCAC3 served as an intermediate system for {delta} {<=} -20{sup 0}. The resulting typical individual mean errors of the proper motions range from 4 mas yr{sup -1} to more than 10 mas yr{sup -1} depending on observational history. The mean errors of positions at epoch 2000.0 are 80-120 mas, if 2MASS astrometry could be used, 150-300 mas else. We also give correction tables to convert USNO-B1.0 observations of, e.g., minor planets to the ICRS system.

79 ASTRONOMY AND ASTROPHYSICS↗

WE-G-BRD-04: BEST IN PHYSICS (JOINT IMAGING-THERAPY): An Integrated Model-Based Intrafractional Organ Motion Tracking Approach with Dynamic MRI in Head and Neck Radiotherapy

Purpose: In-treatment dynamic cine images, provided by the first commercially available MRI-guided radiotherapy system, allow physicians to observe intrafractional motion of head and neck (H&N) internal structures. Nevertheless, high anatomical complexity and relatively poor cine image contrast/resolution have complicated automatic intrafractional motion evaluation. We proposed an integrated model-based approach to automatically delineate and analyze moving structures from on-board cine images. Methods: The H&N upper airway, a complex and highly deformable region wherein severe internal motion often occurs, was selected as the target-to-be-tracked. To reliably capture its motion, a hierarchical structure model containing three statistical shapes (face, face-jaw, and face-jaw-palate) was first built from a set of manually delineated shapes using principal component analysis. An integrated model-fitting algorithm was then employed to align the statistical shapes to the first to-be-detected cine frame, and multi-feature level-set contour propagation was performed to identify the airway shape change in the remaining frames. Ninety sagittal cine MR image sets, acquired from three H&N cancer patients, were utilized to demonstrate this approach. Results: The tracking accuracy was validated by comparing the results to the average of two manual delineations in 20 randomly selected images from each patient. The resulting dice similarity coefficient (93.28+/−1.46 %) and margin error (0.49+/−0.12 mm) showed good agreement with the manual results. Intrafractional displacements of anterior, posterior, inferior, and superior airway boundaries were observed, with values of 2.62+/−2.92, 1.78+/−1.43, 3.51+/−3.99, and 0.68+/−0.89 mm, respectively. The H&N airway motion was found to vary across directions, fractions, and patients, and highly correlated with patients’ respiratory frequency. Conclusion: We proposed the integrated computational approach, which for the first time allows to automatically identify the H&N upper airway and quantify in-treatment H&N internal motion in real-time. This approach can be applied to track other structures’ motion, and provide guidance on patient-specific prediction of intra-/inter-fractional structure displacements.

60 APPLIED LIFE SCIENCES↗

Modeling and Analysis for Spent Nuclear Fuel Seismic Testing

Note: This is the final public release version of PNNL-31671 Draft, which was previously released to the sponsor for review. The intent is the public release version will be PNNL-31671. There are no significant changes from the earlier draft version. This unlimited distribution report is the deliverable for M3SF-21PN010202014: Modeling and Analysis for Spent Nuclear Fuel Seismic Testing. This report summarizes the modeling, analysis, and test plan support completed by Pacific Northwest National Laboratory for the spent nuclear fuel dry storage system seismic test plan through May of 2021. Test plan preparation is planned to continue until the seismic test is completed in July of 2022. This report covers preliminary structural dynamic model development and computer-aided design of test hardware. Based on preliminary modeling, the strongest earthquakes under consideration in this test program provide mechanical loading on the spent nuclear fuel that is comparable to the 30 cm cask drop scenario, although the loads do not appear to be strong enough to cause significant permanent deformation of the fuel assembly spacer grids. The potential for grid deformation during the test will be assessed when the proposed shake table motion becomes available. The weakest earthquakes considered in this test are expected to be comparable to the mechanical loads witnessed in the multimodal transportation test of 2017. The horizontal canister system is predicted to provide nearly-uniform loading condition on the fuel assemblies it contains, while the vertical cask system is predicted to cause non-uniform dynamic loads on the fuel assemblies. In the horizontal case, gravity keeps the fuel assemblies in contact with one basket wall surface unless the loads are strong enough to cause a separation. In the vertical case, the fuel assemblies are relatively long and slender, and seismic motion in the anticipated test range is predicted to cause the assemblies to lean, tilt, and impact the basket walls throughout the seismic event. These gap closures are a nonlinear force transmission condition, so the vertical system is expected to have more variation and variability than the horizontal system. While the horizontal system is expected to have a relatively more linear response than the vertical system, there is still the potential for nonlinear behavior in the horizontal system because the fuel assemblies are free to slide, bounce, and impact the basket walls if the seismic loads are strong enough. One major conclusion of this study is that the use of mixed fuel assemblies in the canister will be acceptable. There are differences in overall system response when the mass, center of gravity, or gaps are changed, but the changes in response are within the bounds of a system that contains completely homogeneous fuel assemblies. One important observation is that the loading for each individual fuel assembly within the vertical canister is expected to be different from that of the others because of nonlinearities in the system. The horizontal canister system is expected to have a more uniform and more predictable response than the vertical canister, making variations in fuel assembly characteristics easier to account for. One important recommendation that comes from this modeling work is to repeat some of the strongest shake tests at different angles, particularly for the vertical cask system. Modeling predicts that strong seismic motion will cause the fuel assemblies to close initial gaps and impact the fuel basket walls when the canister is in the vertical cask configuration. Each shake test will impose a pre-defined three-dimensional time history on the cask system.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Respiratory Motional Effect on Cone-Beam CT in Lung Radiation Surgery

The cone-beam CT (CBCT), which is acquired using an on-board imager (OBI) attached to a linear accelerator, is used effectively in the verification of setup accuracy for lung radiation surgery. In this study, the respiratory organ motional effect on the CBCT was evaluated with a properly devised phantom system, and the level of possible error in conditions of a real clinical process was assessed. In a comparison study between the CBCT in static status and CBCT images acquired in 20 different motional cases, we confirmed that the image quality and information of CBCT were degraded, with an increase of motional ranges in the region of inhomogeneous structures. The 4D-CT MIP (50{approx}55%) for the planning of lung radiation surgery and the 4D-CT MIP (full phase) were compared with CBCT in the various motional cases for the evaluation of the influence of the motional effect on CBCT in the process of the setup error correction. The average ratio of relative difference between plan CT: 4D-CT MIP (50%{approx}55%) and CBCT was 5.79% and between plan CT: 4D-CT MIP (50%{approx}55%) and 4D-CT MIP (full phase) was 42.95% in the phantom study. In the analysis of clinical cases of lung radiation surgery, the gross tumor volumes were compared in each CT image. The average ratio of relative difference between plan CT: 4D-CT MIP (50{approx}55%) and CBCT was 10.72% and between plan CT: 4D-CT MIP (50{approx}55%) and 4D-CT MIP (full phase) was 28.19%. These results showed that, although a respiratory organ motional effect on CBCT introduced variation in image quality, the error as a result of this variation could be estimated relatively low in the setup error correction for a gated-lung radiation surgery when the planning was performed in 4D-CT MIP (50{approx}55%), which already included a related signal of motional effect.

61 RADIATION PROTECTION AND DOSIMETRY↗

Effects of gravitational slip on the higher-order moments of the matter distribution

Cosmological departures from general relativity offer a possible explanation for the cosmic acceleration. To linear order, these departures (quantified by the model-independent parameter {pi}, referred to as a 'gravitational slip') amplify or suppress the growth of structure in the universe relative to what we would expect to see from a general relativistic universe lately dominated by a cosmological constant. As structures collapse and become more dense, linear perturbation theory is an inadequate descriptor of their behavior, and one must extend calculations to nonlinear order. If the effects of gravitational slip extend to these higher orders, we might expect to see a signature of {pi} in the bispectrum of galaxies distributed on the sky. We solve the equations of motion for nonlinear perturbations in the presence of gravitational slip and find that, while there is an effect on the bispectrum, it is too weak to be detected with present galaxy surveys. We also develop a formalism for incorporating scale dependence into our description of gravitational slip.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Observation of the effect of gravity on the motion of antimatter

Einstein’s general theory of relativity from 1915 remains the most successful description of gravitation. From the 1919 solar eclipse to the observation of gravitational waves, the theory has passed many crucial experimental tests. However, the evolving concepts of dark matter and dark energy illustrate that there is much to be learned about the gravitating content of the universe. Singularities in the general theory of relativity and the lack of a quantum theory of gravity suggest that our picture is incomplete. It is thus prudent to explore gravity in exotic physical systems. Antimatter was unknown to Einstein in 1915. Dirac’s theory appeared in 1928; the positron was observed in 1932. There has since been much speculation about gravity and antimatter. The theoretical consensus is that any laboratory mass must be attracted by the Earth, although some authors have considered the cosmological consequences if antimatter should be repelled by matter. In the general theory of relativity, the weak equivalence principle (WEP) requires that all masses react identically to gravity, independent of their internal structure. Here we show that antihydrogen atoms, released from magnetic confinement in the ALPHA-g apparatus, behave in a way consistent with gravitational attraction to the Earth. Repulsive ‘antigravity’ is ruled out in this case. This experiment paves the way for precision studies of the magnitude of the gravitational acceleration between anti-atoms and the Earth to test the WEP.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

PSR J0357+3205: A FAST-MOVING PULSAR WITH A VERY UNUSUAL X-RAY TRAIL

The middle-aged PSR J0357+3205 is a nearby, radio-quiet, bright {gamma}-ray pulsar discovered by the Fermi mission. Our previous Chandra observation revealed a huge, very peculiar structure of diffuse X-ray emission originating at the pulsar position and extending for >9' on the plane of the sky. To better understand the nature of such a nebula, we have studied the proper motion of the parent pulsar. We performed relative astrometry on Chandra images of the field spanning a time baseline of 2.2 yr, unveiling a significant angular displacement of the pulsar counterpart, corresponding to a proper motion of 0.''165 {+-} 0.''030 yr{sup -1} at a position angle (P.A.) of 314 Degree-Sign {+-} 8 Degree-Sign . At a distance of {approx}500 pc, the space velocity of the pulsar would be of {approx}390 km s{sup -1} assuming no inclination with respect to the plane of the sky. The direction of the pulsar proper motion is aligned very well with the main axis of the X-ray nebula (P.A. = 315. Degree-Sign 5 {+-} 1. Degree-Sign 5), pointing to a physical, yet elusive, link between the nebula and the pulsar space velocity. No optical emission in the H{alpha} line is seen in a deep image collected at the Gemini telescope, which implies that the interstellar medium into which the pulsar is moving is fully ionized.

79 ASTRONOMY AND ASTROPHYSICS↗

THE PROPER MOTION OF THE MAGELLANIC CLOUDS. I. FIRST RESULTS AND DESCRIPTION OF THE PROGRAM

We present the first results of a ground-based program to determine the proper motion of the Magellanic Clouds (MCs) relative to background quasars (QSO), being carried out using the Irenee du Pont 2.5 m telescope at Las Campanas Observatory, Chile. Eleven QSO fields have been targeted in the Small Magellanic Cloud (SMC) over a time base of six years, and with seven epochs of observation. One quasar field was targeted in the Large Magellanic Cloud (LMC), over a time base of five years, and with six epochs of observation. The shorter time base in the case of the LMC is compensated by the much larger amount of high-quality astrometry frames that could be secured for the LMC quasar field (124 frames), compared to the SMC fields (an average of roughly 45 frames). In this paper, we present final results for field Q0557-6713 in the LMC and field Q0036-7227 in the SMC. From field Q0557-6713, we have obtained a measured proper motion of {mu}{sub {alpha}}cos {delta} = +1.95 {+-} 0.13 mas yr{sup -1}, {mu}{sub {delta}} = +0.43 {+-} 0.18 mas yr{sup -1} for the LMC. From field Q0036-7227, we have obtained a measured proper motion of {mu}{sub {alpha}} cos{delta} = +0.95 {+-} 0.29 mas yr{sup -1}, {mu}{sub {delta}} = -1.14 {+-} 0.18 mas yr{sup -1} for the SMC. Although we went through the full procedure for another SMC field (QJ0036-7225), on account of unsolvable astrometric difficulties caused by blending of the QSO image, it was impossible to derive a reliable proper motion. Current model rotation curves for the plane of the LMC indicate that the rotational velocity (V {sub rot}) at the position of LMC field Q0557-6713 can be as low as 50 km s{sup -1}, or as high as 120 km s{sup -1}. A correction for perspective and rotation effects leads to a center of mass proper motion for the LMC of {mu}{sub {alpha}} cos{delta} = +1.82 {+-} 0.13 mas yr{sup -1}, {mu}{sub {delta}} = +0.39 {+-} 0.15 mas yr{sup -1} (V {sub rot} = 50 km s{sup -1}), and to {mu}{sub {alpha}} cos{delta} = +1.61 {+-} 0.13 mas yr{sup -1}, {mu}{sub {delta}} = +0.60 {+-} 0.15 mas yr{sup -1} (V {sub rot} = 120 km s{sup -1}). Assuming that the SMC has a disk-like central structure, but that it does not rotate, we obtain a center of mass proper motion for the SMC of {mu}{sub {alpha}} cos{delta} = +1.03 {+-} 0.29 mas yr{sup -1}, {mu}{sub {delta}} = -1.09 {+-} 0.18 mas yr{sup -1}. Our results are in reasonable agreement with most previous determinations of the proper motion of the MCs, including recent Hubble Space Telescope measurements. Complemented with published values of the radial velocity of the centers of the LMC and SMC, we have used our proper motions to derive the galactocentric (gc) velocity components of the MCs. For the LMC, we obtain V {sub gc,t} = +315 {+-} 20 km s{sup -1}, V {sub gc,r} = +86 {+-} 17 km s{sup -1} (V {sub rot} = 50 km s{sup -1}), and V {sub gc,t} = +280 {+-} 24 km s{sup -1}, V {sub gc,r} = +94 {+-} 17 km s{sup -1} (V {sub rot} = 120 km s{sup -1}). For the SMC, we obtain V {sub gc,t} = +258 {+-} 50 km s{sup -1}, V {sub gc,r} = +20 {+-} 44 km s{sup -1}. These velocities imply a relative velocity between the LMC and SMC of 84 {+-} 50 km s{sup -1}, for V {sub rot,LMC} = 50 km s{sup -1}, and 62 {+-} 63 km s{sup -1} for V {sub rot,LMC} = 120 km s{sup -1}. Albeit our large errors, these values are not inconsistent with the standard assumption that the MCs are gravitationally bound to each other.

79 ASTRONOMY AND ASTROPHYSICS↗

An overview of how parity-violating electron scattering experiments are performed at CEBAF

Parity-violating electron-scattering experiments represent an important focus of the nuclear physics experimental program at the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. These experiments pose significant challenges because the scattering asymmetries can be very small, of the order parts-per-million and smaller. To succeed, the properties of the electron beam such as current, position, size and energy, must be very nearly identical in the two electron-polarization spin states (parallel and anti-parallel relative to the direction of beam motion at the scattering target). This paper describes the origins of unwanted helicity-correlated beam asymmetries present on the electron beam and methods to minimize them to acceptable levels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗