Search NASA⌕ Search

SEARCH · Search NASA

Results for “Repair”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

High Basal Levels of γH2AX in Human Induced Pluripotent Stem Cells Are Linked to Replication-Associated DNA Damage and Repair

Abstract Human induced pluripotent stem cells (iPSCs) have great potential as source cells for therapeutic uses. However, reports indicate that iPSCs carry genetic abnormalities, which may impede their medical use. Little is known about mechanisms contributing to intrinsic DNA damage in iPSCs that could lead to genomic instability. In this report, we investigated the level of DNA damage in human iPSC lines compared with their founder fibroblast line and derived mesenchymal stromal cell (MSC) lines using the phosphorylated histone variant, γH2AX, as a marker of DNA damage. We show that human iPSCs have elevated basal levels of γH2AX, which correlate with markers of DNA replication: 5-ethynyl-2′-deoxyuridine and the single-stranded binding protein, replication protein A. γH2AX foci in iPSCs also colocalize to BRCA1 and RAD51, proteins in the homologous repair pathway, implying γH2AX in iPSCs marks sites of double strand breaks. Our study demonstrates an association between increased basal levels of γH2AX and the rapid replication of iPSCs.

Vallabhaneni, Haritha↗

Can Surgeons Assess CT Suitability for Endovascular Repair (EVAR) in Ruptured Abdominal Aortic Aneurysm? Implications for a Ruptured EVAR Trial

The purpose of this study was to determine whether surgeons without formal radiological training are able to assess suitability of patients with ruptured abdominal aortic aneurysms (AAA) for EVAR. The CT scans of 20 patients with AAA were reviewed under timed conditions by six vascular surgeons. Twenty minutes was allocated per scan. They were asked to determine if each aneurysm would be treatable by EVAR in the emergency setting and, if so, to measure for device selection. The results were then compared with those of a vascular radiologist. Six surgeons agreed on the suitability of endovascular repair in 45% of cases (95% CI, 23.1-68.5%; 9/20 scans; {kappa} = 0.41 [p = 0.01]) and concurred with the radiologist in eight of these. Individually, agreement ranged from 13 to 16 of the 20 scans, 65-80% between surgeons. The kappa value for agreement between all the surgeons and the radiologist was 0.47 (p = 0.01, moderate agreement). For the individual surgeons, this ranged from 0.3 to 0.6 (p = 0.01). In conclusion, while overall agreement was moderate between the surgeons and the radiologist, it is clear that if surgeons are to assess patients for ruptured EVAR in the future, focused training of surgical trainees is required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Repair of a Perforation of the Vena Caval Wall Caused by the Retrieval of a Gunther Tulip Filter After Long-Term Implantation

Symptomatic penetration of the inferior vena cava (IVC) wall reportedly occurs in 0.3% of patients in whom a filter has been implanted, and it causes injury to the adjacent structures (Bogue et al. in Pediatr Radiol 39(10):1110-1113, 1; Brzezinski et al. in Burns 32(5):640-643, 2). We succeeded in the endovascular repair of perforation of the IVC wall occurring during the retrieval of a penetrated Gunther tulip vena cava filter (Cook, Bjaeverskov, Denmark) after long-term implantation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intraoperative Sac Pressure Measurement During Endovascular Abdominal Aortic Aneurysm Repair

PurposeIntraoperative sac pressure was measured during endovascular abdominal aortic aneurysm repair (EVAR) to evaluate the clinical significance of sac pressure measurement.MethodsA microcatheter was placed in an aneurysm sac from the contralateral femoral artery, and sac pressure was measured during EVAR procedures in 47 patients. Aortic blood pressure was measured as a control by a catheter from the left brachial artery.ResultsThe systolic sac pressure index (SPI) was 0.87 {+-} 0.10 after main-body deployment, 0.63 {+-} 0.12 after leg deployment (P < 0.01), and 0.56 {+-} 0.12 after completion of the procedure (P < 0.01). Pulse pressure was 55 {+-} 21 mmHg, 23 {+-} 15 mmHg (P < 0.01), and 16 {+-} 12 mmHg (P < 0.01), respectively. SPI showed no significant differences between the Zenith and Excluder stent grafts (0.56 {+-} 0.13 vs. 0.54 {+-} 0.10, NS). Type I endoleak was found in seven patients (15%), and the SPI decreased from 0.62 {+-} 0.10 to 0.55 {+-} 0.10 (P = 0.10) after fixing procedures. Type II endoleak was found in 12 patients (26%) by completion angiography. The SPI showed no difference between type II endoleak positive and negative (0.58 {+-} 0.12 vs. 0.55 {+-} 0.12, NS). There were no significant differences between the final SPI of abdominal aortic aneurysms in which the diameter decreased in the follow-up and that of abdominal aortic aneurysms in which the diameter did not change (0.53 {+-} 0.12 vs. 0.57 {+-} 0.12, NS).ConclusionsSac pressure measurement was useful for instant hemodynamic evaluation of the EVAR procedure, especially in type I endoleaks. However, on the basis of this small study, the SPI cannot be used to reliably predict sac growth or regression.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Maximum Diameter Measurements of Aortic Aneurysms on Axial CT Images After Endovascular Aneurysm Repair: Sufficient for Follow-up?

Purpose: To assess the accuracy of maximum diameter measurements of aortic aneurysms after endovascular aneurysm repair (EVAR) on axial computed tomographic (CT) images in comparison to maximum diameter measurements perpendicular to the intravascular centerline for follow-up by using three-dimensional (3D) volume measurements as the reference standard. Materials and Methods: Forty-nine consecutive patients (73 {+-} 7.5 years, range 51-88 years), who underwent EVAR of an infrarenal aortic aneurysm were retrospectively included. Two blinded readers twice independently measured the maximum aneurysm diameter on axial CT images performed at discharge, and at 1 and 2 years after intervention. The maximum diameter perpendicular to the centerline was automatically measured. Volumes of the aortic aneurysms were calculated by dedicated semiautomated 3D segmentation software (3surgery, 3mensio, the Netherlands). Changes in diameter of 0.5 cm and in volume of 10% were considered clinically significant. Intra- and interobserver agreements were calculated by intraclass correlations (ICC) in a random effects analysis of variance. The two unidimensional measurement methods were correlated to the reference standard. Results: Intra- and interobserver agreements for maximum aneurysm diameter measurements were excellent (ICC = 0.98 and ICC = 0.96, respectively). There was an excellent correlation between maximum aneurysm diameters measured on axial CT images and 3D volume measurements (r = 0.93, P < 0.001) as well as between maximum diameter measurements perpendicular to the centerline and 3D volume measurements (r = 0.93, P < 0.001). Conclusion: Measurements of maximum aneurysm diameters on axial CT images are an accurate, reliable, and robust method for follow-up after EVAR and can be used in daily routine.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality Improvement Guidelines for Imaging Detection and Treatment of Endoleaks following Endovascular Aneurysm Repair (EVAR)

Major concerns after aortic aneurysm repair are caused by the presence of endoleaks, which are defined as persistent perigraft flow within the aortic aneurysm sac. Diagnosis of endoleaks can be performed with various imaging modalities, and indications for treatment are based on further subclassifications. Early detection and correct classification of endoleaks are crucial for planning patient management. The vast majority of endoleaks can be treated successfully by interventional means. Guidelines for Imaging Detection and Treatment of endoleaks are described in this article.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sac Angiography and Glue Embolization in Emergency Endovascular Aneurysm Repair for Ruptured Abdominal Aortic Aneurysm

PurposeThe purpose of this study was to demonstrate a sac angiography technique and evaluate the feasibility of N-butyl cyanoacrylate (NBCA) embolization of the ruptured abdominal aortic aneurysm (AAA) sac in emergency endovascular aneurysm repair (EVAR) in hemodynamically unstable patients.MethodsA retrospective case series of three patients in whom sac angiography was performed during emergency EVAR for ruptured AAA was reviewed. After stent graft deployment, angiography within the sac of aneurysm (sac angiography) was performed by manually injecting 10 ml of contrast material through a catheter to identify the presence and site of active bleeding. In two patients, sac angiography revealed active extravasation of the contrast material, and NBCA embolization with a coaxial catheter system was performed to achieve prompt sealing.ResultsSac angiography was successful in all three patients. In the two patients who underwent NBCA embolization for aneurysm sac bleeding, follow-up computed tomography (CT) images demonstrated the accumulation of NBCA consistent with the bleeding site in preprocedural CT images.ConclusionsEVAR is associated with a potential risk of ongoing bleeding from type II or IV endoleaks into the disrupted aneurysm sac in patients with severe coagulopathy. Therefore, sac angiography and NBCA embolization during emergency EVAR may represent a possible technical improvement in the treatment of ruptured AAA in hemodynamically unstable patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Aneurysm Repair: Is Imaging Surveillance Robust, and Does It Influence Long-term Mortality?

PurposeEndovascular aneurysm repair (EVAR) is the dominant treatment strategy for abdominal aortic aneurysms. However, as a result of uncertainty regarding long-term durability, an ongoing imaging surveillance program is required. The aim of the study was to assess EVAR surveillance in Scotland and its effect on all-cause and aneurysm-related mortality.MethodsA retrospective analysis of all EVAR procedures carried out in the four main Scottish vascular units. The primary outcome measure was the implementation of post-EVAR imaging surveillance across Scotland. Patients were identified locally and then categorized as having complete, incomplete, or no surveillance. Secondary outcome measures were all-cause mortality and aneurysm-related mortality. Cause of death was obtained from death certificates.ResultsData were available for 569 patients from the years 2001 to 2012. All centers had data for a minimum of 5 contiguous years. Surveillance ranged from 1.66 to 4.55 years (median 3.03 years). Overall, 53 % had complete imaging surveillance, 43 % incomplete, and 4 % none. For the whole cohort, all-cause 5-year mortality was 33.5 % (95 % confidence interval 28.0–38.6) and aneurysm-related mortality was 4.5 % (.8–7.3). All-cause mortality in patients with complete, incomplete, and no imaging was 49.9 % (39.2–58.6), 19.1 % (12.6–25.2), and 47.2 % (17.7–66.2), respectively. Aneurysm-related mortality was 3.7 % (1.8–7.4), 4.4 % (2.2–8.9), and 9.5 % (2.5–33.0), respectively. All-cause mortality was significantly higher in patients with complete compared to incomplete imaging surveillance (p < 0.001). No significant differences were observed in aneurysm-related mortality (p = 0.2).ConclusionOnly half of EVAR patients underwent complete long-term imaging surveillance. However, incomplete imaging could not be linked to any increase in mortality. Further work is required to establish the role and deliverability of EVAR imaging surveillance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Can Early Computed Tomography Angiography after Endovascular Aortic Aneurysm Repair Predict the Need for Reintervention in Patients with Type II Endoleak?

PurposeThis study was designed to identify parameters on CT angiography (CTA) of type II endoleaks following endovascular aortic aneurysm repair (EVAR) for abdominal aortic aneurysm (AAA), which can be used to predict the subsequent need for reinterventions.MethodsWe retrospectively identified 62 patients with type II endoleak who underwent early CTA in mean 3.7 ± 1.9 days after EVAR. On the basis of follow-up examinations (mean follow-up period 911 days; range, 373–1,987 days), patients were stratified into two groups: those who did (n = 18) and those who did not (n = 44) require reintervention. CTA characteristics, such as AAA, endoleak, as well as nidus dimensions, patency of the inferior mesenteric artery, number of aortic branch vessels, and the pattern of endoleak appearance, were recorded and correlated with the clinical outcome.ResultsUnivariate and receiver operating characteristic curve regression analyses revealed significant differences between the two groups for the endoleak volume (surveillance group: 1391.6 ± 1427.9 mm{sup 3}; reintervention group: 3227.7 ± 2693.8 mm{sup 3}; cutoff value of 2,386 mm{sup 3}; p = 0.002), the endoleak diameter (13.6 ± 4.3 mm compared with 25.9 ± 9.6 mm; cutoff value of 19 mm; p < 0.0001), the number of aortic branch vessels (2.9 ± 1.2 compared with 4.2 ± 1.4 vessels; p = 0.001), as well as a “complex type” endoleak pattern (13.6 %, n = 6 compared with 44.4 %, n = 8; p = 0.02).ConclusionsEarly CTA can predict the future need for reintervention in patients with type II endoleak. Therefore, treatment decision should be based not only on aneurysm enlargement alone but also on other imaging characteristics.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Medium-Term Outcomes Following Endovascular Repair of Infrarenal Abdominal Aortic Aneurysms with an Unfavourable Proximal Neck

PurposeThe purpose of this study was to evaluate medium-term outcomes following endovascular repair of abdominal aortic aneurysms (EVAR) with unfavourable neck anatomy using stent grafts with a 36 mm or larger proximal diameter.Materials and MethodsA retrospective review of 27 patients who underwent elective EVAR between 2006 and 2008 using a stent graft with a 36 mm or larger proximal diameter was carried out. All patients had computed tomography angiography (CTA) for procedure planning, and detailed assessment of the aneurysm neck was performed using a three-dimensional CTA workstation. Patients were followed up with CTA at 3 and 12 months and annual duplex thereafter.ResultsThe median aneurysm diameter was 7 cm, and the median aneurysm neck diameter was 31 mm. Cook Zenith stent grafts were used in all patients, with a proximal diameter of 36 mm (n = 25) and 40 mm (n = 2). Primary and assisted primary technical success rates were 74 and 93 %, respectively. The follow-up period ranged from 62 to 84 months, with a median of 72 months. 15 patients died during follow-up. Two patients died from aortic rupture, and the remaining patients died from cardiac disease (n = 4), chest sepsis (n = 6), cancer (n = 2) and renal failure (n = 1). Complications included type I endoleak (n = 5), limb occlusion (n = 2), limb stenosis (n = 2), limb kinking (n = 1), dissection of an artery (n = 1), occlusion of a femorofemoral cross-over graft (n = 1) and poor attachment of a distal limb (n = 1).ConclusionsEVAR using stent grafts in the presence of an unfavourable neck has a high risk of complications. Medium-term survival in this group is low but mainly due to patient co-morbidities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Embolization by Direct Puncture with a Transpedicular Approach Using an Isocenter Puncture (ISOP) Method in a Patient with a Type II Endoleak After Endovascular Aortic Repair (EVAR)

BackgroundEndovascular aortic repair (EVAR) requires further intervention in 20-30 % of cases, often due to type II endoleak (T2EL). Management options for T2EL include transarterial embolization, direct puncture (DP), or transcaval embolization. We report the case of an 80-year-old man with T2EL who successfully underwent DP embolization.MethodsEmbolization by DP was performed with a transpedicular approach using an isocenter puncture (ISOP) method. An isocenter marker (ICM) was placed at a site corresponding to the aneurysm sac on fluoroscopy in two directions (frontal and lateral views). A vertebroplasty needle was inserted tangentially to the ICM under fluoroscopy and advanced to the anterior wall of the vertebral body. A 20 cm-length, 20-G-PTCD needle was inserted through the outer needle of the 13-G needle and advanced to the ICM. Sac embolization using 25 % N-buty-2-cyanoacrylate diluted with Lipiodol was performed. After complete embolization, rotational DA confirmed good filling of the sac with Lipiodol. The outer cannula and 13-G needle were removed and the procedure was completed.ResultsThe patient was discharged the next day. Contrast-enhanced computed tomography 1 and 8 months later showed no Lipiodol washout in the aneurysm sac, no endoleak recurrence, and no expansion of the excluded aneurysm.ConclusionDP with a transpedicular approach using ISOP may be useful when translumbar and transabdominal approaches prove difficult.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Unusual Access for the Treatment of Iliac Artery Aneurysm in Association with Type II Endoleak After Endovascular Repair of an Aortoiliac Aneurysm

Internal iliac artery aneurysms (IIAAs), although rare, are associated with a significant risk of mortality, if they rupture. Endovascular approach with exclusion of the aneurysm sac from antegrade and retrograde perfusion is proved to be a feasible treatment option. However, this option is not always technically possible with a preexisting endovascular aneurysm repair (EVAR) or surgical aortoiliac reconstruction with ligation of internal iliac artery origin. We report another safe treatment option of an enlarging IIAA associated with a type II endoleak after EVAR and a standard endovascular treatment was not possible. The access to the aneurysm sac was achieved retrograde via percutaneous access to the superior gluteal artery under fluoroscopy followed by treatment with embolization of the inflow and outflow vessels.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Type II Endoleak After Endovascular Aortic Aneurysm Repair Using the Endurant Stent Graft System for Abdominal Aortic Aneurysm with Occluded Inferior Mesenteric Artery

Purpose: To evaluate the incidence of type II endoleak (EL-II) and aneurysm enlargement after endovascular aneurysm repair (EVAR) using the Endurant stent graft in patients with abdominal aortic aneurysm (AAA) with occluded inferior mesenteric artery (IMA). Materials and Methods: Between 2012 and 2017, 103 patients who underwent EVAR using the Endurant stent graft for AAA with occluded IMA (50 patients with prophylactic embolized IMA and 53 with spontaneous occluded IMA) were retrospectively reviewed. The incidence of EL-II and aneurysm enlargement was evaluated. Predictive factors for persistent EL-II were evaluated based on patient characteristics, preprocedural anatomical characteristics, intraprocedural details, and postprocedural complications. Results: Incidence rates of early EL-II and persistent EL-II were 6.8% (7/103 patients) and 4.9% (5/103 patients), respectively. Aneurysm enlargement was found in 10 patients (9.7%), including all 5 patients with persistent EL-II, 3 with de novo EL-II, and 2 with no EL-II. The rates of freedom from aneurysm enlargement at 1, 2, and 3 years were 98.7%, 97.0%, and 93.1% for the group without persistent EL-II, and 80.0%, 60.0%, and 20.0% for the group with persistent EL-II (p < 0.001), respectively. The maximum aneurysm diameter (odds ratio (OR), 1.16; 95% confidence interval (CI), 1.01–1.34; p = 0.0362) and the number of patent lumbar arteries (OR, 2.72; 95% CI, 1.07–6.90; p = 0.0357) were predictive of persistent EL-II. Conclusions: The incidence of EL-II after EVAR using the Endurant stent graft for AAA with occluded IMA was low, but most early EL-II persisted and resulted in aneurysm enlargement. Level of Evidence Level 4, Case Series.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel Technique for the Treatment of Type 2 Endoleak After Endovascular Aortic Repair: Sac Embolization with Balloon Occlusion of the Aorta (SEBOA)

Purpose: We presented a new method of sac embolization using n-butyl-cyanoacrylate (NBCA) with balloon occlusion of the aorta (SEBOA) that can facilitate decreasing flow rate of the involved branches with the goal of type 2 endoleak resolution after endovascular aortic repair (EVAR). Technique: This technique is demonstrated in six patients who required type 2 endoleak treatment including previous technical failure. A transarterial approach was performed in four patients and transabdominal direct puncture in two. Technical success was defined as complete embolization of both involved branches and sac on postoperative CT. Sacography under balloon occlusion of the aorta demonstrated decreased flow rate of the all involved branches in all patients. SEBOA was performed using 25 or 33% of NBCA diluted with lipiodol. Technical success was obtained in 3 of 6 patients, and one major complication was observed with adhesion of NBCA to the microcatheter resulting in foreign body retention. Conclusion: SEBOA may help solve the difficulty of type 2 endoleak treatment after EVAR as decreased flow rate of the involved branches under balloon occlusion of the aorta was achieved in all patients. However, protocols regarding concentration of NBCA or using other embolic materials are needed to improve the success rate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deficiency of mismatch repair genes is less frequently observed in signet ring cell compared with non-signet ring cell gastric cancer

Signet ring cell (SRC) gastric cancer at advanced stage has poor prognosis. While a recent study reported nearly one-third of SRC cases contain tumors with deficient mismatch repair (MMR) genes, other studies in SRC have been inconclusive. To re-analyze the results, we performed immunohistochemical staining of MLH1, MSH2, MSH6 and PMS2 proteins in 38 SRC gastric tumors compared with 109 non-SRC (NSRC) tumors from 94 patients. In contrast to the previous study, all SRC gastric tumors normally expressed MMR proteins, whereas 22 of 109 of NSRC (20%) showed deficient MMR proteins. To reinforce our results, we referred to the Cancer Genome Atlas (TCGA) genomic database and found that only 6 (6%) of 99 samples with diffuse gastric tumors showed deficient MMR, whereas 64 (21%) of 304 in intestinal gastric tumors showed deficient MMR. Our results as well as the TCGA database indicated that MMR genes are infrequently inactivated in SRC gastric cancer. These findings indicate that SRC patients may not be the best candidates for immuno-oncology therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Repairing large cracks and reversing fatigue damage in structural metals

Self-healing materials represent a paradigm shift from traditional materials development, enabling intrinsic repair of functionality (such as strength) after a catastrophic failure as opposed to part replacement. Several healing mechanisms have been demonstrated in polymeric and ceramic materials, but few in metallic systems. This study demonstrates a novel liquid-assisted self-healing metal-matrix composite (MMC) designed to be capable of over 90% strength recovery after a healing cycle. The aluminum (Al)-based matrix is reinforced with continuous nickel-titanium (NiTi) shape-memory alloy (SMA) reinforcements. Using a tailored heat treatment for healing, a paired effect of crack closure from the SMA reinforcement and partial liquefaction of the matrix occurs. These effects result in a compressive force across the crack surface, and, coupled with increased diffusion rates from the liquefied matrix, produces consolidation and healing in the composite structure. This work provides experimental and computational evidence for the healing mechanism under both tensile and fatigue conditions.

36 MATERIALS SCIENCE↗

Sulforaphane induces DNA double strand breaks predominantly repaired by homologous recombination pathway in human cancer cells

Cytotoxicity and DNA double strand breaks (DSBs) were studied in HeLa cells treated with sulforaphane (SFN), a well-known chemo-preventive agent. Cell survival was impaired by SFN in a concentration and treatment time-dependent manner. Both constant field gel electrophoresis (CFGE) and {gamma}-H2AX assay unambiguously indicated formation of DSBs by SFN, reflecting the cell survival data. These DSBs were predominantly processed by homologous recombination repair (HRR), judging from the SFN concentration-dependent manner of Rad51 foci formation. On the other hand, the phosphorylation of DNA-PKcs, a key non-homologous end joining (NHEJ) protein, was not observed by SFN treatment, suggesting that NHEJ may not be involved in DSBs induced by this chemical. G2/M arrest by SFN, a typical response for cells exposed to ionizing radiation was also observed. Our new data indicate the clear induction of DSBs by SFN and a useful anti-tumor aspect of SFN through the induction of DNA DSBs.

60 APPLIED LIFE SCIENCES↗