Search NASA⌕ Search

SEARCH · Search NASA

Results for “SCINTILLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

X-ray spectroscopy with silicon pin and avalanche photo diodes

Results of an evaluation of silicon P-Intrinsic-N (PIN) photodiodes and Avalanche Photodiodes (APD) for the direct detection of soft x rays from 1 to 20 keV and for the detection of scintillation light output from CsI(TI) for higher x ray energies (30 to 1000 keV) are presented. About one keV resolution was achieved at room temperature for both the PIN and APD detectors for soft x rays (1 to 20 keV). Commercially available, low power (18 mV), low noise, hybrid preamplifiers, were used. These photodiodes were also coupled to CsI(TI) scintillator and obtained about 6 resolution at 662 keV. The photodiode frequency response matches well with the emission spectrum of the CsI(TI) scintillator providing good spectral resolution and a higher signal than NaI(TI) when viewed by conventional photomultipliers. A PIN-CsI(TI) combination provides a low energy threshold of around 60 keV while for the APD-CsI(TI) it is 15 keV.

Desai, U. D.↗

X-ray remote sensing and in-situ spectroscopy for planetary exploration missions and gamma-ray remote sensing and in-situ spectroscopy for planetary exploration missions

Detectors that will be used for planetary missions must have their responses calibrated in a reproducible manner. A calibration facility is being constructed at Schlumberger-Doll Research for gamma and x ray detectors. With this facility the detector response can be determined in an invariant and reproducible fashion. Initial use of the facility is expected for the MARS94 detectors. Work is continuing to better understand the rare earth oxyorthosilicates and to define their characteristics. This will allow a better use of these scintillators for planetary missions. In a survey of scintillating materials two scintillators were identified as promising candidates besides GSO, LSO, and YSO. These are CdWO4 and CsI(Tl). It will be investigated if a detector with a better overall performance can be assembled with various photon converters. Considerable progress was achieved in photomultiplier design. The length of an 1 inch diameter PMT could be reduced from 4.2 to 2.5 inches without performance degradation. This technology is being employed in the gamma ray detector for the NEAR project. A further weight and size reduction of the detector package can be achieved with miniaturized integrated power supplies.

Mahdavi, M.↗

Radio interferometer observations of solar wind turbulence from the orbit of Helios to the solar corona

We report observations of Very Long Baseline Interferometer (VLBI) phase scintillations due to turbulence in the solar wind. The observations were made at 5.00 and 8.42 GHz with the Very Long Baseline Array (VLBA) on three dates in 1991 July and August. We observed the sources 0851 + 202 and 0735 + 178 at solar elongations ranging from 2.66 deg to 13.29 deg; the closest approach of the line of sight to the Sun ranged from 10 to 49.8 solar radii. We have also included previously unpublished 5 GHz VLBI phase scintillation measurements from 1989. These measurements probe solar wind density fluctuations on spatial scales from about 200 km to 2000 km. Our measurements are in quite good agreement with the Coles & Harmon model for the radio phase structure function, which was largely determined from observations on both shorter and larger spatial scales. Departures from the Coles & Harmon functions are attributable to day-to-day variations in the solar wind conditions. Phase scintillations at the greatest solar elongations are in very good agreement with extrapolated estimates from direct measurements made with the Helios spacecraft at slightly larger heliocentric distances. Thus there is a consistency between the in-situ spacecraft and radio sensing measurements of density turbulence. All of the VLBI data are consistent with a Kolmogorov spectrum for the density fluctuations, although at the closest elongations there may be excess power at small spatial scales. An advantage of interferometric techniques over other radio propagation measurements is that they provide a measure of the anisotropy of the irregularities. Our observations at closest approach (10 solar radii) show weak evidence for anisotropic, field-aligned density irregularities with an axial ratio of order 2. This degree of anisotropy would appear to be less than that measured at similar solar elongations but on smaller spatial scales by Armstrong and colleagues. Finally, a combination of the radio propagation data and in situ Helios measurements is used to determine the heliocentric distance dependence of the normalization coefficient of the density power spectrum, C(sup 2)(sub N). Modeling C(sup2)(sub N) varies as (R/solar radii)(sup -Kappa), we find Kappa = 3.72 +/- 0.30. Subject to a number of assumptions, this result is consistent with the conclusion of D. A. Roberts that turbulence within 0.28 astronomical units adheres to a WKB formula for turbulence amplitude as a function of heliocentric distance.

Spangler, Steven R.↗

Fine-Scale Filamentary Structure in Coronal Streamers

Doppler scintillation measurements of a coronal streamer lasting several solar rotations have been conducted by Ulysses in 1991 over a heliocentric distance range of 14-77 R(sub 0). By showing that the solar corona is filamentary, and that Doppler frequency is the radio counterpart of white-light eclipse pictures processed to enhance spatial gradients, it is demonstrated that Doppler scintillation measurements provide the high spatial resolution that has long eluded white-light coronagraph measurements. The region of enhanced scintillation, spanning an angular extent of 1.8 deg in heliographic longitude, coincides with the radially expanding streamer stalk and represents filamentary structure with scale sizes at least as small as 340 km (0.5 sec) when extrapolated to the Sun. Within the stalk of the streamer, the fine-scale structure corresponding to scale sizes in the range of 20-340 km at the Sun and associated with closed magnetic fields amounts to a few percent of the mean density, while outside the stalk, the fine-scale structure associated with open fields is an order of magnitude lower. Clustering of filamentary structure that takes place within the stalk of the streamer is suggestive of multiple current sheets. Comparison with ISEE 3 in situ plasma measurements shows that significant evolution resulting from dynamic interaction with increasing heliocentric distance takes place by the time streamers reach Earth orbit.

Woo, Richard↗

Data Acquisition and Prompt Analysis System for High Altitude Balloon Experiments

An inexpensive and simple data acquisition system has been developed for balloon borne experiments and has been tested with a gamma ray detector in a balloon flight launched from Palestine, Texas. The detector used for the test consisted of an NaI(T1) scintillation crystal encased in a 1/8 in. plastic scintillator-charged particle shield. The combination was viewed by a single photomultiplier and charged particle gating was accomplished by a conventional phoswich discriminator. The pulse height analysis of the NaI events, not associated with prompt charged particle interactions, is accomplished by converting to a time spectrum using an airborne height to time converter. A range of pulse widths from 5 microseconds to 250 microseconds corresponds to energy losses in NaI from 100 to 1000 keV. The time spectrum information, along with charged particle events and barometric pressure, is fed to a mixer which modulates a 252.4 Mc FM transmitter. The original scintillator spectrum is recovered on the ground utilizing conversion circuitry at the receiver video output and a 128 channel commercial pulse height analyzer. The charged particle events of standard time width are stored with the spectrum at a fixed channel position and are therefore represented by a sharp line riding on the lower part of the NaI energy loss spectrum. An energy loss greater than 1000 keV is presented by the maximum pulse width of the converter and stored in the last analyzer channel. Barometric pressure data is transmitted by low frequency modulation of the sme FM carrier. In flight operation, the receiver video output can be recorded on a wide band tape recorder and simultaneously analyzed by the 128 channel analyzer, or the telemetered data can be analyzed later. The flight system features high pulse resolution, essentially instantaneous time response, high data rate, and flexibility; and is of modest cost. A detailed description of the system and operating performance is discussed.

Sarkady, A. A.↗

Ground-to-Ground Optical Communications Demonstration

A bidirectional horizontal-path optical link was demonstrated between Strawberry Peak (SP), Lake Arrowhead, California, and the JPL Table Mountain Facility (TMF), Wrightwood, California, during June and November of 1998. The 0.6-m telescope at TMF was used to broadcast a 4-beam 780-nm beacon to SP. The JPL-patented Optical Communications Demonstrator (OCD) at SP received the beacon, performed ne tracking to compensate for the atmosphere-induced beacon motion and retransmitted a 844-nm communications laser beam modulated at 40 to 500 Mb/s back to TMF. Characteristics of the horizontal-path atmospheric channel as well as performance of the optical communications link were evaluated. The normalized variance of the irradiance fluctuations or scintillation index delta2/I at either end was determined. At TMF where a single 844-nm beam was received by a 0.6-m aperture, the measured delta2/I covered a wide range from 0.07 to 1.08. A single 780-nm beam delta2/I measured at SP using a 0.09-m aperture yielded values ranging from 0.66 to 1.03, while a combination of four beams reduced the scintillation index due to incoherent averaging to 0.22 to 0.40. This reduction reduced the dynamic range of the fluctuations from 17 to 21 dB to 13 to 14 dB as compared with the OCD tracking sensor dynamic range of 10 dB. Predictions of these values also were made based on existing theories and are compared. Generally speaking, the theoretical bounds were reasonable. Discussions on the probability density function (PDF) of the intensity fluctuations are presented and compared with the measurements made. The lognormal PDF was found to agree for the weak scintillation regime as expected. The present measurements support evidence presented by earlier measurements made using the same horizontal path, which suggests that the aperture averaging effect is better than theoretically predicted.

Biswas, A.↗

Microstructured Optical Fiber for X-ray Detection

A novel scintillating optical fiber is presented using a composite micro-structured quartz optical fiber. Scintillating materials are introduced into the multiple inclusions of the fiber. This creates a composite optical fiber having quartz as a cladding with an organic scintillating material core. X-ray detection using these fibers is compared to a collimated cadmium telluride (CdTe) detector over an energy range from 10 to 40 keV. Results show a good correlation between the fiber count rate trend and that of the CdTe detector.

DeHaven, Stanton L.↗

The Super-TIGER Instrument to Probe Galactic Cosmic Ray Origins

Super-TIGER (Super Trans-Iron Galactic Element Recorder) is under construction for the first of two planned Antarctic long-duration balloon flights in December 2012. This new instrument will measure the abundances of ultra-heavy elements (30Zn and heavier), with individual element resolution, to provide sensitive tests of the emerging model of cosmic-ray origins in OB associations and models of the mechanism for selection of nuclei for acceleration. Super-TIGER builds on the techniques of TIGER, which produced the first well-resolved measurements of elemental abundances of the elements 31Ga, 32Ge, and 34Se. Plastic scintillators together with acrylic and silica-aerogel Cherenkov detectors measure particle charge. Scintillating-fiber hodoscopes track particle trajectories. Super-TIGER has an active area of 5.4 sq m, divided into two independent modules. With reduced material thickness to decrease interactions, its effective geometry factor is approx.6.4 times larger than TIGER, allowing it to measure elements up to 42Mo with high statistical precision, and make exploratory measurements up to 56Ba. Super-TIGER will also accurately determine the energy spectra of the more abundant elements from l0Ne to 28Ni between 0.8 and 10 GeV/nucleon to test the hypothesis that microquasars or other sources could superpose spectral features. We will discuss the implications of Super-TIGER measurements for the study of cosmic-ray origins and will present the measurement technique, design, status, and expected performance, including numbers of events and resolution. Details of the hodoscopes, scintillators, and Cherenkov detectors will be given in other presentations at this conference.

Mitchell, John W.↗

Images of Bottomside Irregularities Observed at Topside Altitudes

We analyzed plasma and field measurements acquired by the Communication/ Navigation Outage Forecasting System (C/NOFS) satellite during an eight-hour period on 13-14 January 2010 when strong to moderate 250 MHz scintillation activity was observed at nearby Scintillation Network Decision Aid (SCINDA) ground stations. C/NOFS consistently detected relatively small-scale density and electric field irregularities embedded within large-scale (approx 100 km) structures at topside altitudes. Significant spectral power measured at the Fresnel (approx 1 km) scale size suggests that C/NOFS was magnetically conjugate to bottomside irregularities similar to those directly responsible for the observed scintillations. Simultaneous ion drift and plasma density measurements indicate three distinct types of large-scale irregularities: (1) upward moving depletions, (2) downward moving depletions, and (3) upward moving density enhancements. The first type has the characteristics of equatorial plasma bubbles; the second and third do not. The data suggest that both downward moving depletions and upward moving density enhancements and the embedded small-scale irregularities may be regarded as Alfvenic images of bottomside irregularities. This interpretation is consistent with predictions of previously reported theoretical modeling and with satellite observations of upward-directed Poynting flux in the low-latitude ionosphere.

satellite↗

Advanced Neutron Spectrometer

Energetic neutron measurements remain a challenge for space science investigations and radiation monitoring for human exploration beyond LEO. We are investigating a new composite scintillator design that uses Li6 glass scintillator embedded in a PVT block. A comparison between Li6 and Boron 10 loaded scintillators are being studied to assess the advantages and shortcomings of these two techniques. We present the details of the new Li6 design and results from the comparison of the B10 and Li6 techniques during exposures in a mixed radiation field produced by high energy protons interacting in a target material.

Christl, Mark↗

Random Vibration Testing of Advanced Wet Tantalum Capacitors

Advanced wet tantalum capacitors allow for improved performance of power supply systems along with substantial reduction of size and weight of the systems that is especially beneficial for space electronics. Due to launch-related stresses, acceptance testing of all space systems includes random vibration test (RVT). However, many types of advanced wet tantalum capacitors cannot pass consistently RVT at conditions specified in MIL-PRF-39006, which impedes their use in space projects. This requires a closer look at the existing requirements, modes and mechanisms of failures, specifics of test conditions, and acceptance criteria. In this work, different lots of advanced wet tantalum capacitors from four manufacturers have been tested at step stress random vibration conditions while their currents were monitored before, during, and after the testing. It has been shown that the robustness of the parts and their reliability are mostly due to effective self-healing processes and limited current spiking or minor scintillations caused by RVT do not increase the risk of failures during operation. A simple model for scintillations events has been used to simulate current spiking during RVT and optimize test conditions. The significance of scintillations and possible effects of gas generation have been discussed and test acceptance criteria for limited current spiking have been suggested.

cracking↗

Random Vibration Testing of Advanced Wet Tantalum Capacitors

Advanced wet tantalum capacitors allow for improved performance of power supply systems along with substantial reduction of size and weight of the systems that is especially beneficial for space electronics. Due to launch-related stresses, acceptance testing of all space systems includes random vibration test (RVT). However, many types of advanced wet tantalum capacitors cannot pass consistently RVT at conditions specified in MIL-PRF-39006, which impedes their use in space projects. This requires a closer look at the existing requirements, modes and mechanisms of failures, specifics of test conditions, and acceptance criteria. In this work, different lots of advanced wet tantalum capacitors from four manufacturers have been tested at step stress random vibration conditions while their currents were monitored before, during, and after the testing. It has been shown that the robustness of the parts and their reliability are mostly due to effective self-healing processes and limited current spiking or minor scintillations caused by RVT do not increase the risk of failures during operation. A simple model for scintillations events has been used to simulate current spiking during RVT and optimize test conditions. The significance of scintillations and possible effects of gas generation have been discussed and test acceptance criteria for limited current spiking have been suggested.

cracking↗

Random Vibration Testing of Advanced Wet Tantalum Capacitors

Advanced wet tantalum capacitors allow for improved performance of power supply systems along with substantial reduction of size and weight of the systems that is especially beneficial for space electronics. Due to launch-related stresses, acceptance testing of all space systems includes random vibration test (RVT). However, many types of advanced wet tantalum capacitors cannot pass consistently RVT at conditions specified in MIL-PRF-39006, which impedes their use in space projects. This requires a closer look at the existing requirements, modes and mechanisms of failures, specifics of test conditions, and acceptance criteria. In this work, different lots of advanced wet tantalum capacitors from four manufacturers have been tested at step stress random vibration conditions while their currents were monitored before, during, and after the testing. It has been shown that the robustness of the parts and their reliability are mostly due to effective self-healing processes and limited current spiking or minor scintillations caused by RVT do not increase the risk of failures during operation. A simple model for scintillations events has been used to simulate current spiking during RVT and optimize test conditions. The significance of scintillations and possible effects of gas generation have been discussed and test acceptance criteria for limited current spiking have been suggested.

wet tantalum capacitors↗

Investigation of Deuterium Loaded Materials Subject to X-Ray Exposure

Results are presented from an exploratory study involving x-ray irradiation of select deuterated materials. Titanium deuteride plus deuterated polyethylene, deuterated polyethylene alone, and for control, hydrogen-based polyethylene samples and nondeuterated titanium samples were exposed to x-ray irradiation. These samples were exposed to various energy levels from 65 to 280 kV with prescribed electron flux from 500 to 9000 μA impinging on a tungsten braking target, with total exposure times ranging from 55 to 280 min. Gamma activity was measured using a high-purity germanium (HPGe) detector, and for all samples no gamma activity above background was detected. Alpha and beta activities were measured using a gas proportional counter, and for select samples beta activity was measured with a liquid scintillator spectrometer. The majority of the deuterated materials subjected to the microfocus x-ray irradiation exhibited postexposure beta activity above background and several showed short-lived alpha activity. The HPE and nondeuterated titanium control samples exposed to the x-ray irradiation showed no postexposure alpha or beta activities above background. Several of the samples (SL10A, SL16, SL17A) showed beta activity above background with a greater than 4σ confidence level, months after exposure. Portions of SL10A, SL16, and SL17A samples were also scanned using a beta scintillator and found to have beta activity in the tritium energy band, continuing without noticeable decay for over 12 months. Beta scintillation investigation of as-received materials (before x-ray exposure) showed no beta activity in the tritium energy band, indicating the beta emitters were not in the starting materials.

x-ray irradiation↗

Breakdown and Self-healing in Tantalum Capacitors

Reliability of tantalum capacitors depends on the efficiency of self-healing that restores parts after breakdown. In this work, different types of polymer and MnO2 cathode capacitors have been tested for scintillation breakdown using a constant current stress (CCS) technique modified to allow detection of amplitudes and duration of current spikes. Monitoring of leakage currents with time under bias is used to assess the effect of scintillations. The appearance and composition of damaged sites have been examined after deprocessing and cross-sectioning. Thermal processes during scintillations have been analyzed, a mechanism of breakdown based on growth of conductive filaments in the dielectric suggested, and self-healing processes in polymer and MnO2 cathode capacitors discussed.

tantalum capacitor↗

Breakdown in Tantalum Capacitors

Failures in tantalum capacitors can be considered as a time-dependent-breakdown and reliability of all types of capacitors, including wet, MnO2 and polymer cathode parts, depends on the efficiency of self-healing that can mend parts after breakdown. A mechanism of self-healing in MnO2 capacitors is associated with oxygen reduction in the cathode layer and isolation of the breakdown site with high-resistive Mn2O3/Mn3O4 compositions. Although this mechanism is commonly accepted, details of self-healing have not been analyzed sufficiently yet, and the effects of scintillations on behavior of the parts has not been fully understood. There is a lack of data on the self-healing efficiency in different lots of capacitors. Even less is known about self-healing in polymer tantalum capacitors. In this work, different types of polymer and MnO2 capacitors have been tested for scintillation breakdown using a constant current stress (CCS) technique modified to allow detection of the amplitudes and durations of current spikes during breakdown. Characteristics of the parts and in particular leakage currents were measured to assess the efficiency of self-healing and improve screening processes for tantalum capacitors. Damaged sites were localized using infrared camera and their appearance analyzed after deprocessing and crosssectioning. Thermal effects during scintillations have been modeled, self-healing processes in polymer and MnO2 cathode capacitors discussed, and mechanisms of breakdown based on the growth of conductive filaments in the dielectric suggested.

tantalum polymer capacitors↗

Analysis and Validation of PMT s Waveforms in ICARUS LArTPC Using Monte Carlo Simulations

ICARUS (Imaging Cosmic and Rare Underground Signals) serves as the Far Detector in the Short Baseline Neutrino (SBN) program at Fermilab, playing a central role in investigating the potential existence of sterile neutrinos in the eV squared mass range. The detector consists of two large Liquid Argon Time Projection Chambers (LArTPCs) with a total capacity of 760 tons of liquid Argon. A key component of the system is its array of 360 Photo-Multiplier Tubes (PMTs), which detect the scintillation light produced by charged particles in liquid Argon; the fast scintillation signal enables accurate event timing, triggering, and reconstruction. Together with the TPC and CRT systems, the PMTs ensure precise interaction time measurements, which are crucial for distinguishing neutrino interactions from cosmic-ray backgrounds. ICARUS uses Hamamatsu R5912-MOD PMTs, optimized for cryogenic temperatures, with high quantum efficiency, excellent timing resolution, low dark current (around 10 nA at 1500 V), and broad spectral sensitivity (300–650 nm). These characteristics are crucial for the efficient detection of scintillation light. Analyzing the waveforms of PMT signals allows for a detailed comparison between experimental data and Monte Carlo simulations. This analysis is fundamental for improving the accuracy of neutrino event reconstruction, enhancing detector calibration, and optimizing the detector's performance for current and future operations.

Brio, V. [Catania U.] (ORCID:0009000088807391)↗

Pushing the Limits of Pulse Shape Discrimination in a Large Liquid Xenon Detector

The LUX-ZEPLIN (LZ) experiment is a direct-detection dark matter experiment, optimized to search for weakly interacting massive particles (WIMPs) through WIMP-nucleon interactions. The main challenge in dark matter detection is differentiating between WIMP signals and background events. In LZ, the ratio of ionization to scintillation signals (charge-to-light) is the primary method for rejecting electronic recoil (ER) background. Pulse shape discrimination (PSD) offers a method for additional ER backgrounds rejection in liquid xenon detectors. In this paper, the discrimination power of PSD with the LZ experiment is discussed. To precisely characterize the scintillation pulse shape, an analysis framework is developed to reconstruct the detection time of individual photons. Using LZ calibration data, the photon-timing prompt fraction discriminator is optimized and achieves ER leakage as low as $15\%$. For specific background processes such as $^{124}$Xe double electron capture, the leakage is reduced further to about $5\%$. PSD is combined with charge-to-light to form two-factor discrimination (TFD). The optimized TFD performance is compared with the performance of the charge-to-light method, with the corresponding false positive rate reduced by up to a factor of two for large scintillation pulses. Finally, PSD and TFD are applied to data from LZ's WS2024 run and their performance is summarized.

Akerib, D. S. [SLAC; KIPAC, Menlo Park]↗