Search NASA⌕ Search

SEARCH · Search NASA

Results for “SIZE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Probabilistic Estimation of Critical Flaw Sizes in the Primary Structure Welds of the Ares I-X Launch Vehicle

The primary structure of the Ares I-X Upper Stage Simulator (USS) launch vehicle is constructed of welded mild steel plates. There is some concern over the possibility of structural failure due to welding flaws. It was considered critical to quantify the impact of uncertainties in residual stress, material porosity, applied loads, and material and crack growth properties on the reliability of the welds during its pre-flight and flight. A criterion--an existing maximum size crack at the weld toe must be smaller than the maximum allowable flaw size--was established to estimate the reliability of the welds. A spectrum of maximum allowable flaw sizes was developed for different possible combinations of all of the above listed variables by performing probabilistic crack growth analyses using the ANSYS finite element analysis code in conjunction with the NASGRO crack growth code. Two alternative methods were used to account for residual stresses: (1) The mean residual stress was assumed to be 41 ksi and a limit was set on the net section flow stress during crack propagation. The critical flaw size was determined by parametrically increasing the initial flaw size and detecting if this limit was exceeded during four complete flight cycles, and (2) The mean residual stress was assumed to be 49.6 ksi (the parent material s yield strength) and the net section flow stress limit was ignored. The critical flaw size was determined by parametrically increasing the initial flaw size and detecting if catastrophic crack growth occurred during four complete flight cycles. Both surface-crack models and through-crack models were utilized to characterize cracks in the weld toe.

Pai, Shantaram S.↗

Effects of Ice Particle Size Vertical Inhomogeneity on the Passive Remote Sensing of Ice Clouds

The solar reflectance bi-spectral (SRBS) and infrared split-window (IRSpW) methods are two of the most popular techniques for passive ice cloud property retrievals from multispectral imagers. Ice clouds are usually assumed to be vertically homogeneous in global operational algorithms based on these methods, although significant vertical variations of ice particle size are typically observed in ice clouds. In this Study we investigate uncertainties in retrieved optical thickness, effective particle size, and ice water path introduced by a homogeneous cloud assumption in both the SRBS and IRSpW methods, and focus on whether the assumption can lead to significant discrepancies between the two methods. The study simulates the upwelling spectral radiance associated with vertically structured clouds and passes the results through representative SRBS and IRSpW retrieval algorithms. Cloud optical thickness is limited to values for which IRSpW retrievals are possible (optical thickness less than about 7). When the ice cloud is optically thin and yet has a significant ice particle size vertical variation, it is found that both methods tend to underestimate the effective radius and ice water path. The reason for the underestimation is the nonlinear dependence of ice particle scattering properties (extinction and single scattering albedo) on the effective radius. Because the nonlinearity effect is stronger in the IRSpW than the SRBS method, the IRSpW-based IWP tends to be smaller than the SRBS counterpart. When the ice cloud is moderately optically thick, the IRSpW method is relatively insensitive to cloud vertical structure and effective radius retrieval is weighted toward smaller ice particle size, while the weighting function makes the SRBS method more sensitive to the ice particle size in the upper portion of the cloud. As a result, when ice particle size increases monotonically toward cloud base, the two methods are in qualitative agreement; in the event that ice particle size decreases toward cloud base, the effective radius and ice water path retrievals based on the SRBS method are substantially larger than those from the IRSpW. The main findings of this Study Suggest that the homogenous cloud assumption can affect the SRBS and IRSpW methods to different extents and, consequently, can lead to significantly different retrievals. Therefore caution should be taken when comparing and combining the ice cloud property retrievals from these two methods.

Zhang, Zhibo↗

Influence of Finite Element Size in Residual Strength Prediction of Composite Structures

The sensitivity of failure load to the element size used in a progressive failure analysis (PFA) of carbon composite center notched laminates is evaluated. The sensitivity study employs a PFA methodology previously developed by the authors consisting of Hashin-Rotem intra-laminar fiber and matrix failure criteria and a complete stress degradation scheme for damage simulation. The approach is implemented with a user defined subroutine in the ABAQUS/Explicit finite element package. The effect of element size near the notch tips on residual strength predictions was assessed for a brittle failure mode with a parametric study that included three laminates of varying material system, thickness and stacking sequence. The study resulted in the selection of an element size of 0.09 in. X 0.09 in., which was later used for predicting crack paths and failure loads in sandwich panels and monolithic laminated panels. Comparison of predicted crack paths and failure loads for these panels agreed well with experimental observations. Additionally, the element size vs. normalized failure load relationship, determined in the parametric study, was used to evaluate strength-scaling factors for three different element sizes. The failure loads predicted with all three element sizes provided converged failure loads with respect to that corresponding with the 0.09 in. X 0.09 in. element size. Though preliminary in nature, the strength-scaling concept has the potential to greatly reduce the computational time required for PFA and can enable the analysis of large scale structural components where failure is dominated by fiber failure in tension.

Satyanarayana, Arunkumar↗

Centrifugal Sieve for Gravity-Level-Independent Size Segregation of Granular Materials

Conventional size segregation or screening in batch mode, using stacked vibrated screens, is often a time-consuming process. Utilization of centrifugal force instead of gravity as the primary body force can significantly shorten the time to segregate feedstock into a set of different-sized fractions. Likewise, under reduced gravity or microgravity, a centrifugal sieve system would function as well as it does terrestrially. When vibratory and mechanical blade sieving screens designed for terrestrial conditions were tested under lunar gravity conditions, they did not function well. The centrifugal sieving design of this technology overcomes the issues that prevented sieves designed for terrestrial conditions from functioning under reduced gravity. These sieves feature a rotating outer (cylindrical or conical) screen wall, rotating fast enough for the centrifugal forces near the wall to hold granular material against the rotating screen. Conventional centrifugal sieves have a stationary screen and rapidly rotating blades that shear the granular solid near the stationary screen, and effect the sieving process assisted by the airflow inside the unit. The centrifugal sieves of this new design may (or may not) have an inner blade or blades, moving relative to the rotating wall screen. Some continuous flow embodiments would have no inner auger or blades, but achieve axial motion through vibration. In all cases, the shearing action is gentler than conventional centrifugal sieves, which have very high velocity differences between the stationary outer screen and the rapidly rotating blades. The new design does not depend on airflow in the sieving unit, so it will function just as well in vacuum as in air. One advantage of the innovation for batch sieving is that a batch-mode centrifugal sieve may accomplish the same sieving operation in much less time than a conventional stacked set of vibrated screens (which utilize gravity as the primary driving force for size separation). In continuous mode, the centrifugal sieves can provide steady streams of fine and coarse material separated from a mixed feedstock flow stream. The centrifugal sieves can be scaled to any desired size and/or mass flow rate. Thus, they could be made in sizes suitable for small robotic exploratory missions, or for semi-permanent processing of regolith for extraction of volatiles of minerals. An advantage of the continuous-mode system is that it can be made with absolutely no gravity flow components for feeding material into, or for extracting the separated size streams from, the centrifugal sieve. Thus, the system is capable of functioning in a true microgravity environment. Another advantage of the continuous-mode system is that some embodiments of the innovation have no internal blades or vanes, and thus, can be designed to handle a very wide range of feedstock sizes, including occasional very large oversized pieces, without jamming or seizing up.

Walton, Otis R.↗

The Relationship Of Size Distributions To Spectral (300 - 700 Nm) Extinction Parameterization Of Ambient In Situ Aerosols Measured During FIREX-AQ And The Influence Of Aerosol Composition

Hyperspectral (300 - 700 nm, 0.7 nm resolution) aerosol extinction spectra were measured at seven fires in six states in the western United States during the Fire Influence on Regional to Global Environments and Air Quality (FIREX-AQ) field campaign in July and August 2019. Obtained using an in situ aerosol sampling method, these spectra are directly comparable to other in situ aerosol measurements such as size distribution and composition. A previous deployment of the in situ Spectral Aerosol Extinction (SpEx) instrument that measured fine mode aerosols (50% size cut of 1.3 µm particle diameter) around the Korean peninsula showed that over this spectral range 2nd order polynomials provided a better fit to the logarithmically transformed spectra than linear fits (representative of Ångström exponents). The two fit parameters (a1, a2) of the polynomials are related to the classic Ångström exponent but provide additional information via their two-dimensional parameter space. The previous work was limited by the lack of commensurate size distribution information. Here, using the FIREX-AQ spectra set it is possible to expand on the previous analysis in three specific ways: 1) size distribution information is available to further elucidate how size distribution maps into (a1, a2) space, 2) the sampled size distributions include larger particles than the Korean study, and 3) the FIREX-AQ data set exhibits smoke-related spectral features in the UV part of the spectrum that are not present in background air nor were they observed previously in the Korean study. The UV spectral features are particularly intriguing as they likely arise from the absorption component of the extinction measurement and therefore may be related to composition. The relationships between the ambient in situ aerosol size distributions, the extinction spectra, and composition will be presented.

Carolyn Jordan↗

Effect of Varying HUT Sizing on Human-Spacesuit Contact Patterns

Fit, comfort, and mobility of the spacesuit rely on the location, magnitude, and type of contact between the suit and wearer. Typically, spacesuits include the Hard Upper Torso (HUT) comprising the upper torso of the spacesuit. Potential injuries from hard contact between the wearer’s shoulders and the HUT are a concern; therefore, to investigate spacesuit-wearer contact patterns, data from a retrospective study was analyzed. This study had eight subjects wearing the Shuttle Extravehicular Mobility Unit (EMU) spacesuit in two configurations, one with a nominally sized HUT and another with an oversized HUT. The subjects were sized per the NASA standard suit fit procedure. The suit’s arms and lower body were also resized to provide nominal arm and lower body fit, accounting for the larger HUT. Subjects held various shoulder postures (neutral posture, and various maximum shoulder rotations) with the suit pressurized to 4.3 PSI. For each posture, subjects reported the intensity of their perceived contact with the suit on a Borg CR10 scale, 0 indicating a non-existent contact intensity, and 10 representing a maximal contact intensity. Ratings were recorded for 11 regions covering the upper body and these ratings were used to determine the impact of body shape and size on suit contact. Our preliminary findings suggest that oversized HUTs had less contact regions than compared to the nominal HUT; and the region of contact, contact patterns, and contact intensities varied from person to person with the oversized HUT. This variance could be linked to subjects’ body shape and size. The next goal is to establish a causal factor between body shape and size, pose, contact region, and the HUT size. The outcome is expected to help understand the overall contact trends and insights into the influence of HUT sizing on suit fit.

Will Green↗

Laboratory Radar Measurements in Support of the NASA Orbital Debris Program Office’s Size Estimation Model

The NASA Orbital Debris Program Office (ODPO) relies on ground-based radar measurements from both the Haystack Ultrawideband Satellite Imaging Radar (HUSIR) and the Goldstone Solar System Radar (Goldstone) to characterize mm to cm debris population in low Earth orbit (LEO). Radar measurements help characterize the size of orbital debris objects, particularly fragmentation debris. However, debris size is not directly measured by radar but inferred from the measured radar cross section (RCS) which depends on several parameters in addition to physical size including electrical conductivity and polarization. To interpret the observed RCS of orbital debris objects detected by radar measurements as physical sizes, NASA uses an empirical size estimation model (SEM) based on laboratory RCS measurements of breakup fragments generated during hypervelocity impact tests as well as some pieces of non-impact-generated “artificial” debris-like objects expected to be representative of the debris population. Since the development of the ODPO SEM, many new materials have been introduced to spacecraft construction. Consequently, ODPO plans to update the radar SEM based on planned laboratory RCS measurements of debris fragments from DebriSat, a ground-based hypervelocity impact experiment conducted in 2014 that consisted of a high-fidelity spacecraft model characteristic of a modern LEO spacecraft. Prior to measuring DebriSat fragments, a set of calibration targets with well-defined geometries and material compositions were measured at The Ohio State University’s ElectroScience Laboratory (OSU-ESL) compact radar range. These calibration measurements help to validate, and understand any limitations of, laboratory measurements of RCS. Calibration targets include idealizations of typical shape categories seen in DebriSat fragments such as nuggets, flat plates, and cylinders. As with DebriSat, calibration target materials were chosen to represent typical modern-day spacecraft components and include stainless steel, aluminum, printed circuit board (PCB) substrate, and carbon fiber-reinforced polymer (CFRP). These materials also represent a wide range of electrical conductivities, which strongly influences measured RCS and inferred target size. The RCS calibration measurements were collected over a frequency sweep from 2 to 18 GHz and stepping through different azimuth angles from 0 to 360 degrees at an elevation of 0 degrees. A second set of calibration measurements is in work consisting of more complex shapes such as bent rods and plates as well as different mounting options including epoxy and a 3D printed holder. These further measurements along with our initial calibration set will inform selection of representative DebriSat fragments for laboratory RCS measurements that will contribute to the planned update to the ODPO radar SEM. An appropriate subset of both the radar calibration and DebriSat samples will also be measured in the ODPO Optical Measurements Center to cross-calibrate size estimates over these different wavelength regimes.

Radar↗

Structural, Dynamical and Electronic Transport Properties of Modified DNA Duplexes Containing Size-Expanded Nucleobases

Among the distinct strategies proposed to expand the genetic alphabet, size-expanded nucleobases are promising for the development of modified DNA duplexes with improved biotechnological properties. In particular, duplexes built up by replacing canonical bases with the corresponding benzo-fused counterparts could be valuable as molecular nanowires. In this context, this study reports the results of classical molecular dynamics simulations carried out to examine the structural and dynamical features of size-expanded DNAs, including both hybrid duplexes containing mixed pairs of natural and benzo-fused bases (xDNA) and pure size-expanded (xxDNA) duplexes. Furthermore, the electronic structure of both natural and size-expanded duplexes is examined by means of density functional computations. The results confirm that the structural and flexibility properties of the canonical DNA are globally little affected by the presence of benzo-fused bases. The most relevant differences are found in the enhanced size of the grooves, and the reduction in the twist. However, the analysis also reveals subtle structural effects related to the nature and sequence of benzo-fused bases in the duplex. On the other hand, electronic structure calculations performed for xxDNAs confirm the reduction in the HOMO-LUMO gap predicted from the analysis of the natural bases and their size-expanded counterparts, which suggests that pure size-expanded DNAs can be good conductors. A more complex situation is found for xDNAs, where fluctuations in the electrostatic interaction between base pairs exerts a decisive influence on the modulation of the energy gap.

59 BASIC BIOLOGICAL SCIENCES↗

A fast integrated mobility spectrometer for rapid measurement of sub-micrometer aerosol size distribution, Part I: Design and model evaluation

This study discusses, a fast integrated mobility spectrometer (FIMS) was previously developed to characterize submicron aerosol size distributions at a frequency of 1 Hz and with high size resolution and counting statistics. However, the dynamic size range of the FIMS was limited to one decade in particle electrical mobility. It was proposed that the FIMS dynamic size range can be greatly increased by using a spatially varying electric field. This electric field creates regions with drastically different field strengths in the separator, such that particles of a wide diameter range can be simultaneously classified and subsequently measured. A FIMS incorporating this spatially varying electric field is developed. This paper describes the theoretical frame work and numerical simulations of the FIMS with extended dynamic size range, including the spatially varying electric field, particle trajectories, activation of separated particles in the condenser, and the transfer function, transmission efficiency, and mobility resolution. The influences of the particle Brownian motion on FIMS transfer function and mobility resolution are examined. The simulation results indicate that the FIMS incorporating the spatially varying electric field is capable of measuring aerosol size distribution from 8 to 600 nm with high time resolution. As a result, the experimental characterization of the FIMS is presented in an accompanying paper.

54 ENVIRONMENTAL SCIENCES↗

THE PHYSICS OF PROTOPLANETESIMAL DUST AGGLOMERATES. VI. EROSION OF LARGE AGGREGATES AS A SOURCE OF MICROMETER-SIZED PARTICLES

Observed protoplanetary disks consist of a large amount of micrometer-sized particles. Dullemond and Dominik pointed out for the first time the difficulty in explaining the strong mid-infrared excess of classical T Tauri stars without any dust-retention mechanisms. Because high relative velocities in between micrometer-sized and macroscopic particles exist in protoplanetary disks, we present experimental results on the erosion of macroscopic agglomerates consisting of micrometer-sized spherical particles via the impact of micrometer-sized particles. We find that after an initial phase, in which an impacting particle erodes up to 10 particles of an agglomerate, the impacting particles compress the agglomerate's surface, which partly passivates the agglomerates against erosion. Due to this effect, the erosion halts for impact velocities up to {approx}30 m s{sup -1} within our error bars. For higher velocities, the erosion is reduced by an order of magnitude. This outcome is explained and confirmed by a numerical model. In a next step, we build an analytical disk model and implement the experimentally found erosive effect. The model shows that erosion is a strong source of micrometer-sized particles in a protoplanetary disk. Finally, we use the stationary solution of this model to explain the amount of micrometer-sized particles in the observational infrared data of Furlan et al.

79 ASTRONOMY AND ASTROPHYSICS↗

Nasa Glenn Icing Research Tunnel: 2018 Change in Drop-Sizing Equations Due to Change in Cloud Droplet Probe Sample Area

Although there has been no physical change to the cloud drop diameters in the NASA Glenn Icing Research Tunnel (IRT), the IRT cloud calibration team now has an improved understanding of the facility’s drop-sizing instrumentation, which has resulted in a recent change to the drop-sizing equations. Only the calculated values given in the previous calibration report have changed. In 2017, IRT staff found reason to believe that since at least 2014, the sample area for its Cloud Droplet Probe (CDP) (Droplet Measurement Technologies, Inc.) has been closer to 0.289 mm2, rather than the user manual’s suggested value of 0.24 mm2. In September 2017, the probe’s sample area was measured both before and after the probe was realigned, and the end sample area was measured to be 0.248 mm2. Following the probe’s realignment, drop size measurements were made in the IRT using the CDP as well as optical array probes OAP–230X and OAP–230Y (Particle Measurement Systems, Inc.). These measurements suggested that 0.289 mm2 was the more accurate value for historical measurements. When the CDP sample area used for calculations was changed from 0.24 to 0.289 mm2, distributions previously reported to have a median volumetric diameter (MVD) between 30 and 100 μm were instead calculated to have MVD values 10 to 18 percent higher. The analyses that led to these conclusions are reported in this paper, as well as the new drop-sizing equations that have been developed for the corrected measurement values. This report contains updates to drop-sizing data for the IRT’s “normal” operating conditions (MVD < 50 μm) and discusses the effects on the IRT’s “large-drop” conditions (Mod1 nozzles, Pair < 10 psig), but it does not include updates to the drop-sizing equations for those large-drop conditions.

Particle sizing↗

Size‐Induced Ferroelectricity in Antiferroelectric Oxide Membranes

Abstract Despite extensive studies on size effects in ferroelectrics, how structures and properties evolve in antiferroelectrics with reduced dimensions still remains elusive. Given the enormous potential of utilizing antiferroelectrics for high‐energy‐density storage applications, understanding their size effects will provide key information for optimizing device performances at small scales. Here, the fundamental intrinsic size dependence of antiferroelectricity in lead‐free NaNbO 3 membranes is investigated. Via a wide range of experimental and theoretical approaches, an intriguing antiferroelectric‐to‐ferroelectric transition upon reducing membrane thickness is probed. This size effect leads to a ferroelectric single‐phase below 40 nm, as well as a mixed‐phase state with ferroelectric and antiferroelectric orders coexisting above this critical thickness. Furthermore, it is shown that the antiferroelectric and ferroelectric orders are electrically switchable. First‐principle calculations further reveal that the observed transition is driven by the structural distortion arising from the membrane surface. This work provides direct experimental evidence for intrinsic size‐driven scaling in antiferroelectrics and demonstrates enormous potential of utilizing size effects to drive emergent properties in environmentally benign lead‐free oxides with the membrane platform.

36 MATERIALS SCIENCE↗

Agent-based simulations of shared automated vehicle operations: reflecting travel-party size, season and day-of-week demand variations

Here, this paper explores the effects of day of week and season of year demand variations for shared rides, along with realistic travel party sizes, on shared autonomous vehicle (SAV) services across the Austin, Texas region. Using the agent-based POLARIS program, synthetic person-trips that reflect travel-party size (from one to four persons) and demand variations over days and months, as evident in the National Household Travel Survey data were simulated in each scenario over a 24 h travel day. Results show that realistic party sizes can bring considerable changes to SAV fleet performance, including up to 8.5% higher service rates (number of requests accepted within 15 min), 5 min shorter journey times (wait time + travel time), 28% higher vehicle occupancies on weekends, and roughly 4% lower empty fleet VMT. Weekend travel is most impacted by season of year, with weekday travel patterns looking more uniform (thanks to work and school trips). Various performance metrics for the Austin network, like total and empty VMT, change by up to 30% when considering realistic variations in party size and time of year. This paper underscores the value of recognizing day-to-day and month-to-month variations in travel demand, and the importance of agent-based model equations to reflect travel-party size. Such realism can help quantify SAV seat occupancies more accurately, highlighting the importance of shared mobility. However, it also creates demand and supply issues for operators that now need more information on party size to manage dynamic ride-sharing, or those that may wish to shift their fleet vehicles to other regions for special events to protect profits while offering reasonable wait times to customers throughout the year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Influence of heat treatment on the size of sodium lignosulfonate particles in water—ethanol media

Dynamic light scattering and size exclusion chromatography were used to investigate the size of sodium lignosulfonate particles in water—ethanol media and the changes occurring at temperatures of 115–440 °C (13 MPa). It was found that the characteristic size (diameter) of particles of the starting sodium lignosulfonate in solutions with a concentration of 1.5 and 13.3 g L{sup −1} was 2.2−5.2 nm. Treatment in a flow reactor at temperature of 235–325 °C led to a disintegration of larger particles with an increase in the fraction of particles with size of 2.2 nm and a simultaneous formation of particles with a size of ~100 nm. Increasing the treatment temperature (>415 °C) led to a complete disappearance of particles with size of 2.2–5.2 nm and the formation of particles 100–130 nm in diameter, as well as the precipitation of large soot-like particles. IR spectroscopy showed that increasing the treatment temperature above 275 °C led to a decrease in the specific content of oxygen-containing and sulfoxyl groups in the sodium lignosulfonate structure, with the exception of carboxyl groups, whose fraction remained almost unchanged, as well as CH{sub 3} groups (methoxy and aliphatic), whose content increased slightly. The temperature range of 235–275 °C was optimal for hydrolysis of sodium lignosulfonate and preparation of aromatic monomers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of Current Parameters and Size Effects on Mechanical Properties During Pulsed Electrically Assisted Uniaxial Tension in T2 Red Copper Sheets

It has been found that the electrically assisted (EA) forming can alleviate size effects due to the electroplastic effect. Size effects exist in the manufacture of tiny workpieces and severely affect material performances because the grain boundary hardening effect and strong anisotropy of the mechanical properties of the grains will lead to a strong variation in the forming properties of the sheet. In order to investigate the influences of current parameters and size effects on mechanical properties in EA forming, EA uniaxial tension tests with varying grain size and thickness were conducted on T2 red copper sheets. The small temperature rise shows the thermal effect is slight; the flow stress decreases with the increase in pulse frequency, pulse duty ratio and current density; the finer grains still result in higher strength and better plasticity; Moreover, the fluctuations of tensile strength, maximum uniform strain and fracture strain decrease with the increase in the ratio of thickness to grain size (N) at constant current density, which means pulsed current can weaken size effects.

36 MATERIALS SCIENCE↗

A statistical and simulation-informed model for estimating permeability from pore size distribution in saturated geomaterials

Accurate permeability estimation is essential across subsurface engineering applications but remains challenging due to the complex pore structures of natural geomaterials. Traditional empirical methods and simplified theoretical models often inadequately capture the role of pore size distribution and connectivity. Here, this study develops a statistical and simulation-informed permeability model that collapses pore-scale complexity into a compact scaling of the form k = αϕμ d 2 , where ϕ is porosity, μ d is mean pore size, and α is a weakly varying coefficient. By combining pore network simulations with statistical analysis of unimodal and bimodal pore size distributions, we identify three key findings: (i) permeability is much more sensitive to mean pore size than to porosity; (ii) across extensive datasets, the ratio σ d /μ d (standard deviation to mean) clusters around a characteristic value ∼0.4, allowing the effects of the full pore size distribution to be represented by μ d and a narrowly varying α ≈ 0.05; and (iii) for bimodal systems, there exists a critical fraction of small pores ∼0.78 above which flow becomes small-pore dominated, enabling the definition of an effective flow-controlling pore population and facilitating simplified permeability estimation for such systems. The resulting model, which requires only porosity and a representative mean pore size as inputs, is validated against comprehensive experimental datasets (>1700 samples) spanning diverse soils and rocks and achieves good predictive accuracy. Overall, this work provides a physically grounded yet practically simple permeability estimator suitable for subsurface engineering, environmental protection, and resource management applications.

Permeability↗

Structural origin of size effect on piezoelectric performance of Pb(Zr,Ti)O 3

Grain size effect plays a vital role in piezoelectric performance from both scientific and technological view. However, the underlying structural mechanism related to grain size is still unclear. In the present study, the structural mechanism of grain size effect on piezoelectric performance has been revealed in the prototype Pb(Zr, Ti)O 3 system by using in-situ synchrotron X-ray diffraction. The miniaturization of grain size tends to favor the appearance of higher symmetric tetragonal phase, while a single monoclinic phase is determined in the coarse-grained ceramics. The direct structural evidence reveals that both tetragonal and monoclinic phases in the fine-grained ceramics are less sensitive to the electric field, corresponding to the inferior piezoelectric performance, while the single monoclinic phase in the coarse-grained ceramics is more active to be driven by the electric field, generating good piezoelectric behavior. Both domain switching ability and lattice strain are suppressed with decreasing grain size, which directly leads to the deterioration in piezoelectric performance. In conclusion, the current results will benefit the structural understanding of the size effect of piezoelectric and other related systems.

36 MATERIALS SCIENCE↗

Impact of particle size on distribution and human exposure of flame retardants in indoor dust

Highlights: • Indoor dust from office/public microenvironments/cars were separated into 6 size fractions. • FR distribution was dependent on Kow/dust surface area/TOC/FR migration pathway. • OPFR bioaccessibility was 1.8–82%, bioaccessible PBDEs/NBFRs/DPs were < detection limit. • Human exposure to FR was dependent on dust particle size and bioaccessibility. The effect of dust particle size on the distribution and bioaccessibility of flame retardants (FRs) in indoor dust remains unclear. In this study, we analyzed 20 FRs (including 6 organophosphate flame retardants (OPFRs), 8 polybrominated diphenyl ethers (PBDEs), 4 novel brominated flame retardants (NBFRs), and 2 dechlorane plus (DPs)) in composite dust samples from offices, public microenvironments (PME), and cars in Nanjing, China. Each composite sample (one per microenvironment) was separated into 6 size fractions (F1–F6: 200–2000 µm, 150–200 µm, 100–150 µm, 63–100 µm, 43–63 µm, and 9). Bioaccessibility of FRs was measured by the physiologically-based extraction test, with OPFR bioaccessibility being 1.8–82% while bioaccessible PBDEs, NBFRs, and DPs were under detection limits due to their high hydrophobicity. The OPFR bioaccessibility in 200–2000 µm fraction was significantly higher than that of <43 µm fraction, but with no difference among the other four fractions. Risk assessment was performed for the most abundant OPFR-tris(2-chloroethyl) phosphate. The average daily dose (ADD) values were the highest for the <43 µm fraction for all three types of dust using total concentrations, but no consistent trend was found among the three types of dust if based on bioaccessible concentrations. Our results indicated that dust size impacted human exposure estimation of FRs due to their variability in distribution and bioaccessibility among different fractions. For future risk assessment, size selection for dust sampling should be standardized and bioaccessibility of FRs should not be overlooked.

54 ENVIRONMENTAL SCIENCES↗