Displaceable spur gear torque controlled driver and method

Methods and apparatus are provided for a torque driver including a laterally displaceable gear support member to carry an output spur gear. A biasing assembly biases the output spur gear into engagement with a pinion to which is applied an input torque greater than a desired output torque limit for a threaded fastener such as a nut or screw. A coiled output linkage connects the output spur gear with a fastener adaptor which may be a socket for a nut. A gear tooth profile provides a separation force that overcomes the bias to limit torque at the desired torque limit. Multiple fasteners may be rotated simultaneously to a desired torque limit if additional output spur gears are provided. A gauged selector mechanism is provided to laterally displace multiple driver members for fasteners arranged in differing configurations. The torque limit is selectably adjustable and may be different for fasteners within the same fastener configuration.

Cook, Joseph S., Jr.↗

Parameter dimension of turbulence-induced phase errors and its effects on estimation in phase diversity

The method of phase diversity has been used in the context of incoherent imaging to estimate jointly an object that is being imaged and phase aberrations induced by atmospheric turbulence. The method requires a parametric model for the phase-aberration function. Typically, the parameters are coefficients to a finite set of basis functions. Care must be taken in selecting a parameterization that properly balances accuracy in the representation of the phase-aberration function with stability in the estimates. It is well known that over parameterization can result in unstable estimates. Thus a certain amount of model mismatch is often desirable. We derive expressions that quantify the bias and variance in object and aberration estimates as a function of parameter dimension.

Thelen, Brian J.↗

Displaceable Spur Gear Torque Controlled Driver and Method

Methods and apparatus are provided for a torque driver including a laterally displaceable gear support member to carry an output spur gear. A biasing assembly biases the output spur gear into engagement with a pinion to which is applied an input torque greater than a desired output torque limit for a threaded fastener such as a nut or screw. A coiled output linkage connects the output spur gear with a fastener adaptor which may be a socket for a nut. A gear tooth profile provides a separation force that overcomes the bias to limit torque at the desired torque limit. Multiple fasteners may be rotated simultaneously to a desired torque limit if additional output spur gears are provided. A gauged selector mechanism is provided to laterally displace multiple driven members for fasteners arranged in differing configurations. The torque limit is selectably adjustable and may be different for fasteners within the same fastener configuration.

Cook, Joseph S., Jr.↗

Does Collection Time Bias the Ecology of Cleanroom Air Samples?

Microbial monitoring of astromaterials collections has taken on increased importance with the return of biologically sensitive samples from the asteroids Ryugu and Bennu and the initiation of the Mars Sample Return Program. Terrestrial bacteria and fungi can alter the mineralogy and organic composition of our collections causing irreversible contamination of pristine samples and increasing the risk of false positives for life detection measurements. NASA has conducted routine microbial monitoring of its existing collections since 20181. Initial monitoring focused on surface samples collected with foam swabs. Although, airborne microbiology is often decoupled from surface microbiology in the built environment2 culture-based air sampling techniques like impactors were not compliant with existing contamination control requirements. Bringing organic rich media, gelatin or liquids into curation cleanrooms presents an unacceptable risk to pristine samples. In 2022 NASA purchased a materials complaint air sampler and began collecting air samples from the cleanrooms in addition to surface samples3. The new instrument uses an electret filter to collect samples that are suitable for cultivating organisms or for direct DNA sequencing. Preliminary DNA sequencing results appeared to indicate that longer sampling times biased the microbial community in favor of hearty, spore-forming bacteria3. We present the results of a study comparing overnight sampling (17 hours) to short (1 hour) sampling of unoccupied curation cleanrooms. The results will help us optimize our monitoring protocols and develop a more detailed inventory of the ecology of astromaterials curation cleanrooms. Methods: We analyzed 72 paired air samples from six different cleanrooms including the meteorite processing lab (ISO 7 equivalent, 16 samples), the lunar lab (ISO 6 equivalent, 10 samples), the stardust lab (ISO 5 equivalent 14 samples), the OSIRIS-REx lab (ISO 5 equivalent, 12 samples), the Hayabusa2 lab (ISO 5 equivalent, 14 samples), and the Genesis lab (ISO 4 equivalent, 6 samples). All the samples were collected with an InnovaPrep Bobcat air sampler operating at a sampling rate of 200 L/min. The sampler operates for 5 minutes out of every 20 minute period. Half of the samples were collected by filtering 3,000L (15 min. of active sampling) of air across an electret filter for one hour. The rest of the samples were collected by filtering approximately 51,000 L air across the filter overnight (~17 hours, 255 min. of active sampling). Cells were eluted from the filter using 6-7 ml of pressurized 0.15% tween 20 in PBS (phosphate buffered saline). This liquid was used to cultivate bacteria according to previously published methods1,4,5 and for DNA extraction and next generation sequencing. DNA was extracted with a Qiagen MagAttract PowerMicrobiome kit6. To identify bacteria and archaea, the 16S rRNA gene was amplified using Earth Microbiome primers for the V4 region 7. The amplified DNA was sequenced on an Illumina MiSeq using a V3 reagent kit. The resulting sequences were processed using DADA2 and QIIME2 as implemented on the EDGE bioinformatics platform8–10. Results: Only two of the 72 samples had no amplifiable DNA. Amplified DNA concentrations ranged from 2.67 – 0.272 ng/µl. The median concentration of amplified DNA for the 1 hour samples was 0.770 ± 0.368 ng/µl. The median concentration of amplified DNA for the overnight samples was 0.877 ± 0.434 ng/µl. On average the overnight samples had slightly more sequences (58,960 vs. 59,456) and ASV’s (amplicon sequence variants) (60 vs 64.5) than the one hour samples, but these differences are not statistically significant. The most abundant ASV in every sample mapped to the genus Cupravidus. ASV’s mapping to the genuses Bacillus, Schlegelella, Thermus, and Staphylococcus were also common. Discussion and Future Work: Alpha diversity statistics like Shannon Entropy and Faith Phylogenetic Diversity are used to describe the diversity of organisms in a single sample. If a longer sampling time was biasing the data, we would expect to see a change in these diversity statistics vs. sample time. However, we did not observe this in our data. The median Shannon entropy was slightly higher for the overnight samples (3.773 vs 3.611) as was the Faith Phylogenetic Diversity (4.042 vs 3.596), but both values were within a standard deviation of each other for the two sampling times (Fig. 1). It is unlikely, that the longer sampling time is introducing bias into our data. We do observe a significant decrease in diversity when comparing the air samples by lab. The Genesis lab (ISO 4 equivalent) has a lower median number of ASV’s (45.5) than the other labs (62). Median values for Shannon Entropy (3.717 vs. 3.430) and Faith Phylogenetic Diversity (3.796 vs. 3.548) are also lower for Genesis, but those values are with one standard deviation of each other for the different sampling times. This is consistent with previous culture-based results suggesting that the environment in cleanrooms tends to select for a core group of organisms capable of surviving under dry, low nutrient, conditions. The presence of the ASV’s mapping to Cupravidus and Thermus in our sequencing blanks and controls suggests that several of the most common organisms in our samples represent contaminants from the reagents used to perform the DNA extractions and sequencing. Further work is needed to identify these contaminants, remove them from our data and recalculate the diversity statistics. This is a systematic error. Therefore, we do not expect removing the sequencing contaminants to change our conclusions. Longer air sample collection times appear to result in slightly higher diversity and do not bias the results towards “hardy” bacteria like spore-formers. Based on these preliminary results we conclude that sampling at least 3,000 liters of air is sufficient to capture the microbial diversity of cleanrooms, and that air samples can also be collected overnight without negatively impacting diversity. These results allow us to be flexible when designing microbial monitoring plans so that they do not interfere with routine lab activity. References: 1. Regberg, A. B. et al. 49th Lunar and Planetary Science Conference (2018). 2. The United States Pharmacopeial Convention. USP General Chapter <1116> (2013). 3. Regberg, A. B., et al. 54th Lunar and Planetary Science Conference (2023). 4. Regberg, A. B. et al. 53rd Lunar and Planetary Science Conference ( 2022). 5. Davis, R. E.,et al. 50th Lunar and Planetary Science Conference (2019). 6. Qiagen. MagAttract® PowerMicrobiome® DNA/RNA EP Kit Handbook. (2018). 7. Walters, W. et al. mSystems 1, (2015). 8. Callahan, B. J. et al. Nat. Methods 13, 581–583 (2016). 9. Hall, M. & Beiko, R. G. Microbiome Analysis: Methods and Protocols113–129 (Springer, 2018). 10. Philipson, C. et al. Bio-Protoc. 7, e2622 (2017).

A. B. Regberg↗

Facets control charge separation during photoelectrochemical water oxidation with strontium titanate (SrTiO 3 ) single crystals

The photocatalytic overall water splitting reaction provides a pathway to hydrogen fuel from sunlight. Photocatalysts must achieve the reaction without the application of an external bias, which requires an effective charge separation mechanism. Photolabeling studies and electrostatic simulations for the well-known CoOOH/Al:SrTiO 3 /Rh/Cr 2 O 3 photocatalyst suggest that charge separation is driven by work function differences at the (100) and (110) facets of SrTiO 3 , which are electron and hole selective, respectively. Here we use hydrogen annealed SrTiO 3–x single crystals to obtain the first quantitative assessment of the charge separation ability of the (100), or (110), or (111) facets during oxygen evolution. Under UV illumination (60 mW cm –2 ), the crystals exhibit variable water oxidation photocurrents (0.34, 0.82, 1.36 mA cm –2 at 1.23 V versus RHE) and photovoltage values of 1.40, 1.52 and 1.52 V for (100), (110), and (111) SrTiO 3–x , respectively. A surface photovoltage increase in that same order (0.31 V < 0.57 V < 0.67 V) is confirmed independently with vibrating Kelvin probe surface photovoltage spectroscopy (VKP-SPV) under 375 nm (1.91 mW cm –2 ) illumination. Mott Schottky measurements in aqueous K 3/4 [Fe(CN) 6 ] reveal facet-dependent flatband positions of –0.58, –0.71, and –0.74 V RHE for the (100), (110), and (111) crystals respectively. This confirms that the photoelectrochemical water oxidation performance of SrTiO 3–x crystals is controlled by the work function of each facet, which determines the electron transfer barrier height of the respective solid–liquid junctions. After correcting for differences in electron donor concentrations, barriers are found to increase in the order (100) < (111) < (110) and differ by as much as 0.16 eV, similar to an earlier prediction. Altogehter, these results explain the charge separation mechanism in SrTiO 3 photocatalysts and highlight the need for faceted semiconductor crystals as light absorbers in particle-based photocatalysts.

08 HYDROGEN↗

Accelerating Biological Insight for Understudied Genes

Synopsis The rapid expansion of genome sequence data is increasing the discovery of protein-coding genes across all domains of life. Annotating these genes with reliable functional information is necessary to understand evolution, to define the full biochemical space accessed by nature, and to identify target genes for biotechnology improvements. The majority of proteins are annotated based on sequence conservation with no specific biological, biochemical, genetic, or cellular function identified. Recent technical advances throughout the biological sciences enable experimental research on these understudied protein-coding genes in a broader collection of species. However, scientists have incentives and biases to continue focusing on well documented genes within their preferred model organism. This perspective suggests a research model that seeks to break historic silos of research bias by enabling interdisciplinary teams to accelerate biological functional annotation. We propose an initiative to develop coordinated projects of collaborating evolutionary biologists, cell biologists, geneticists, and biochemists that will focus on subsets of target genes in multiple model organisms. Concurrent analysis in multiple organisms takes advantage of evolutionary divergence and selection, which causes individual species to be better suited as experimental models for specific genes. Most importantly, multisystem approaches would encourage transdisciplinary critical thinking and hypothesis testing that is inherently slow in current biological research.

Zoology↗

Illustrating galaxy–halo connection in the DESI era with illustrisTNG

ABSTRACT We employ the hydrodynamical simulation illustrisTNG to inform the galaxy–halo connection of the Luminous Red Galaxy (LRG) and Emission Line Galaxy (ELG) samples of the Dark Energy Spectroscopic Instrument (DESI) survey at redshift z ∼ 0.8. Specifically, we model the galaxy colours of illustrisTNG and apply sliding DESI colour–magnitude cuts, matching the DESI target densities. We study the halo occupation distribution (HOD) model of the selected samples by matching them to their corresponding dark matter haloes in the illustrisTNG dark matter run. We find the HOD of both the LRG and ELG samples to be consistent with their respective baseline models, but also we find important deviations from common assumptions about the satellite distribution, velocity bias, and galaxy secondary biases. We identify strong evidence for concentration-based and environment-based occupational variance in both samples, an effect known as ‘galaxy assembly bias’. The central and satellite galaxies have distinct dependencies on secondary halo properties, showing that centrals and satellites have distinct evolutionary trajectories and should be modelled separately. These results serve to inform the necessary complexities in modelling galaxy–halo connection for DESI analyses and also prepare for building high-fidelity mock galaxies. Finally, we present a shuffling-based clustering analysis that reveals a 10–15 ${{\ \rm per\ cent}}$ excess in the LRG clustering of modest statistical significance due to secondary galaxy biases. We also find a similar excess signature for the ELGs, but with much lower statistical significance. When a larger hydrodynamical simulation volume becomes available, we expect our analysis pipeline to pinpoint the exact sources of such excess clustering signatures.

79 ASTRONOMY AND ASTROPHYSICS↗

Dopant Sensitive Electrolytic Etching of Germanium with High Selectivity

Abstract The enhanced charge carrier mobility and photon absorption compared to silicon make germanium attractive for next-generation photo diodes. However, the complex oxidation behavior of germanium challenges dopant-dependent selective etching that is desired for the fabrication of backside imaging architectures. This report demonstrates electrolytic wet etching of p-doped germanium which proceeds up to 17,500x faster than etching of intrinsic germanium. Homoepitaxially grown layers of germanium were electrolytically etched in potassium hydroxide over a range of biases. Intermittent acquisition of cyclic voltammetry spectra during etching has suppressed the formation of electric double layers, maintained appreciable etch rates, and allowed for in operando process control. The observed etch rates scaled with dopant concentration. An effective etch rate of germanium removal of 2.100±0.044 µm/min was accomplished for a boron dopant concentration of 6E18cm-3. For nominally intrinsic germanium, however, an effective etch rate of only 0.00012±0.00011 µm/min was observed. A series of systematic electrolytic etch experiments have revealed the transfer of 4 electrons per germanium atom removed.

Wood, Joseph G.↗

Application of multiple criteria decision methods in space exploration initiative design and planning

Fellowship activities were directed towards the identification of opportunities for application of the Multiple Criteria Decision Making (MCDM) techniques in the Space Exploration Initiative (SEI) domain. I identified several application possibilities and proposed demonstration application in these three areas: evaluation and ranking of SEI architectures, space mission planning and selection, and space system design. Here, only the first problem is discussed. The most meaningful result of the analysis is the wide separation between the two top ranked architectures, indicating a significant preference difference between them. It must also be noted that the final ranking reflects, to some extent, the biases of the evaluators and their understanding of the architecture.

Masud, Abu S. M.↗

Calibrating a 3-Axis Accelerometer Instrument with a Less Accurate Calibration Device Part 1: Mathematical Methodology

A three-axis accelerometer instrument (3xAI) can provide the angular attitude of a 3D object using the gravity vector (g) as the sole reference. Calibrating such an instrument requires placing it at known (to some accuracy plus uncertainty) angular articulations with respect to g. This paper will show a potential process for calibrating a 3xAI by using a 2-axis rotary system (calibration device) to provide these articulations. Any calibration device (CD) with such capacity will contain internal misalignments. These misalignments, even if made relatively small or approximated to zero in the kinematics model (KM), can be detrimental to the calibration of the instrument when high measurement accuracy is required. This is especially true if the selected set of articulations chosen for calibration do not include their symmetrical counterpoints (a point where the misalignment has equal magnitude but is opposite in direction to a point chosen). The consequence of not including the combination, point and counterpoint, for any misalignment involved in the calibration, results in a biased instrument. This paper will demonstrate a calibration of the instrument using symbolic math resulting in a closed-form solution of the instrument coefficients. The main objective is to show the impact of all the CD misalignments to the instrument coefficients. This process is the basis for a more sophisticated method (shown in a future paper) for obtaining the instrument coefficients while simultaneously obtaining an estimate of the calibration device internal misalignments.

Angle↗

Versatile allelic replacement and self-excising integrative vectors for plasmid genome mutation and complementation

ABSTRACT The ability to better understand the function of proteins expressed by bacteria has typically relied upon the development of genetic mutant strains. This approach has been especially challenging for plasmid-encoded genes, as most of the previously described allelic replacement vectors are inefficient for plasmid genome mutation as they either rely on plasmid-derived counterselection toxins or depend on other strategies suchsacB,tetA, andrpsLwhich have been proven to be less efficient for mutant selection. Integrative vectors lack chromophore indicators, thus requiring laborious screening or excision of the vector’s backbone relies on the introduction of a flippase (FLP)-expressing plasmid. The allelic replacement vector, designated here as pDG1, expresses an X-Gal hydrolyzing enzyme (BgaB) that can be used for blue/white screening allowing identification of colonies that integrated and successfully removed the mutagenesis plasmid without a bias for those still carrying it. pDG1 was further improved by including the rhamnose-inducible Tse2 toxin as a potent counterselection system. The efficacy of pDG1 was validated by deleting portions of the plasmid-encoded VirB4/D4 type IV secretion system and aerobactin-synthesizing operons inSalmonella enterica. The integrative vectors, which contain an ΦC31attPsite and genes encoding ΦC31 integrase (int), can seamlessly integrate to target ΦC31attBonSalmonellaplasmids or chromosome. These vectors were improved by insertingbgaBand FLP-encoding genes so that, following integration, most of the vector’s backbone encompassingint,bgaB, and FLP genes can be excised by FLP, without the need for another FLP-expressing vector, creating white colonies carrying a stably integrated target gene. As such, we were able to integrate a 9.3-kb DNA fragment toSalmonellachromosome and flipped out most of the integrated vector in one step, leaving the target fragment in the chromosome. IMPORTANCE In spite of the dissemination of multidrug-resistant plasmids among Gram-negative pathogens, including those carrying virulence genes, vector tools for studying plasmid-born genes are lacking. The allelic replacement vectors can be used to generate plasmid or chromosomal mutations including markless point mutations. This is the first report describing a self-excising integrative vector that can be used as a stable single-copy complementing tool to study medically important pathogens includingin vivostudies without the need for antibiotic selection. Overall, our newly developed vectors can be applied for the assessment of the function of plasmid-encoded genes by specifically creating mutations, moving large operons between plasmids and to/from the chromosome, and complementing phenotypes associated with gene mutation. Furthermore, the vectors express chromophores for the detection of target gene modification or colony isolation, avoiding time-consuming screening procedures.

Microbiology↗

The miniJPAS survey: AGN and host galaxy coevolution of X-ray-selected sources

Studies indicate strong evidence of a scaling relation in the local Universe between the supermassive black hole mass (MBH) and the stellar mass of their host galaxies (M * ). They even show similar histories across cosmic times of their differential terms: the star formation rate (SFR) and black hole accretion rate (BHAR). However, a clear picture of this coevolution is far from being understood. We selected an X-ray sample of active galactic nuclei (AGN) up to z = 2.5 in the miniJPAS footprint. Their X-ray to infrared spectral energy distributions (SEDs) have been modeled with the CIGALE code, constraining the emission to 68 bands, from which 54 are the narrow filters from the miniJPAS survey. For a final sample of 308 galaxies, we derived their physical properties, such as their M * , SFR, star formation history (SFH), and the luminosity produced by the accretion process of the central BH (L AGN ). For a subsample of 113 sources, we also fit their optical spectra to obtain the gas velocity dispersion from the broad emission lines and estimated the M BH . We calculated the BHAR in physical units depending on two radiative efficiency regimes. We find that the Eddington ratios (λ Edd ) and its popular proxy (L X /M * ) have a difference of 0.6 dex, on average, and a KS test indicates that they come from different distributions. Our sources exhibit a considerable scatter on the MBH - M * scaling relation, which can explain the difference between λ Edd and its proxy. We also modeled three evolution scenarios for each source to recover the integral properties at z = 0. Using the SFR and BHAR, we show a notable diminution in the scattering between MBH - M * . For the last scenario, we considered the SFH and a simple energy budget for the AGN accretion, and we retrieved a relation similar to the calibrations known for the local Universe. Our study covers ~1 deg 2 in the sky and is sensitive to biases in luminosity. Nevertheless, we show that, for bright sources, the link between the differential values (SFR and BHAR) and their decoupling based on an energy limit is the key that leads to the local M BH - M * scaling relation. In the future, we plan to extend this methodology to a thousand degrees of the sky using JPAS with an X-ray selection from eROSITA, to obtain an unbiased distribution of BHAR and Eddington ratios.

79 ASTRONOMY AND ASTROPHYSICS↗

From noise to information: The transfer function formalism for uncertainty quantification in reconstructing the nuclear density

The neutron distribution of neutron-rich nuclei provides critical information on the structure of finite nuclei and neutron stars. Parity violating experiments—such as PREX and CREX—provide a clean and largely model-independent determination of neutron densities. Such experiments, however, are challenging and expensive, which is why sound statistical arguments are required to maximize the information gained. We introduce a new framework, the “transfer function formalism,” aimed at uncertainty quantification, model selection, and experimental design in the context of neutron densities. The transfer functions (TFs) are built analytically by expressing the linear response of the objective function (e.g., χ2) to small perturbations of the data. Using the TF formalism, we are able to analyze the expected overall uncertainty—quantified in terms of bias and variance—of the mean square radius and interior density of 48 Ca and 208 Pb. Using relativistic mean field models as a proxy for the weak-charge density—and assuming that a total of five measurements could be performed on the weak form factor of 48 Ca and 208 Pb—we identify the optimal models and experimental locations that minimize the uncertainty in the extraction of the radius and interior density. We also explore the use of the TF formalism to understand the influence of prior distributions for the model parameters, as well as the optimization of model hyperparameters not constrained by the data. Here,we establish how the choice of experimental locations and the model that is used can have a significant impact on the final uncertainties of the extracted quantities of interest. For challenging experiments such as CREX and PREX, a proper quantification of such uncertainties is critical. We have demonstrated how the TF formalism provides several advantages for this type of analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Magnetostrictive Ultrasonic Waveguide Transducer for In-Pile Thermometry

Real-time and reliable temperature measurement on nuclear fuels is crucial for the safe operation of existing pressurized-water reactors and future advanced nuclear reactors. Magnetostrictive materials deform when subjected to a magnetic field or exhibit magnetization variation when stressed. Here, based on these properties, this study prototyped an ultrasonic thermometer (UT) consisting of a magnetostrictive waveguide, a dc coil providing appropriate magnetic biasing, and an ac coil generating an acoustic impulse and detecting the resulting acoustic echoes. By tracking the time of flight between the excitation pulse and the echoes, the UT can potentially detect nuclear fuel cladding temperature from a long distance. In this study, magnetostrictive iron–gallium alloys, or Galfenol, were selected as the waveguide due to their large magnetostriction, superior temperature survivability, excellent radiation resilience, and high mechanical robustness. A multiphysics finite-element model considering electrical, magnetic, and mechanical dynamics in the magnetostrictive UT was then developed. The model exhibited an error of 0.24% in time-of-flight simulation and, therefore, enabled computer-aided design and guided signal processing. Between room temperature and 120 °C, the new Galfenol-based UT exhibits a linear sensitivity of 162.8×10 ₋6 °C ₋1 , which is 51.7% higher than a previous magnetostrictive UT based on iron–cobalt–vanadium alloys.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Comparison of Multi-Angle Implementation of Atmospheric Correction and MOD09 Daily Surface Reflectance Products from MODIS

This study presents the first systematic comparison of MAIAC Collection 6 MCD19A1 daily surface reflectance (SR) product with standard MODIS SR (MOD/MYD09). The study was limited to four tiles located in mid-Atlantic United States (H11V05), Canada (H12V03),central Amazon (H11V09), and North-Eastern China (H27V05) and used over 5000 MODIS granules in 2018. Overall, there is a remarkable agreement between the best quality pixels of the two products, in particular in the Red and NIR bands. Over selected tiles, the evaluation found that MAIAC provides from 4 to 25% more high-quality retrievals thanMOD09 annually, with the largest difference in tropical regions, confirming results of the previous studies. The comparison of spectral characteristics showed a systematic MAIAC-MOD09 difference increasing from NIR to Blue, typical of biases of a Lambertian assumption in MOD09 algorithm. Over the North-Eastern China, MCD19A1 SR is found more stable at wide range of aerosol optical depth (AOD) variations, whereasMOD09 SR shows a consistent positive bias increasing with AOD and at shorter wavelengths. The observed SR differences can be attributed to differences in cloud detection, aerosol retrieval and in atmospheric correction which is performed using an accurate BRDF-coupled radiative transfer model in MAIAC and a Lambertian surface model in MOD09. While this study is not representative of the global performance because of its limited geographical coverage, it should help the land community to better understand the differences between the two products.

MAIAC↗

High-speed laser anemometry based on spectrally resolved Rayleigh scattering

Laser anemometry in unseeded flows based on the measurement of the spectrum of Rayleigh scattered laser light is reviewed. The use of molecular scattering avoids the well known problems (particle lag, biasing effects, seed generation, seed injection) of seeded flows. The fundamental limits on velocity measurement accuracy are determined using maximum likelihood methods. Measurement of the Rayleigh spectrum with scanning Fabry-Perot interferometers is analyzed and accuracy limits are established for both single pass and multipass configurations. Multipass configurations have much higher selectivity and are needed for measurements where there is a large amount of excess noise caused by stray laser light. It is shown that Rayleigh scattering is particularly useful for supersonic and hypersonic flows. The results of the analysis are compared with measurements obtained with a Rayleigh scattering diagnostic developed for study of the exhaust plume of a small hydrogen-oxygen rocket, where the velocities are in the range of 1000 to 5000 m/sec.

Seasholtz, Richard G.↗

The 2006 Cape Canaveral Air Force Station Range Reference Atmosphere Model Validation Study and Sensitivity Analysis to the National Aeronautics and Space Administration's Space Shuttle

NASA's Space Shuttle utilizes atmospheric thermodynamic properties to evaluate structural dynamics and vehicle flight performance impacts by the atmosphere during ascent. Statistical characteristics of atmospheric thermodynamic properties at Kennedy Space Center (KSC) used in Space. Shuttle Vehicle assessments are contained in the Cape Canaveral Air Force Station (CCAFS) Range Reference Atmosphere (RRA) Database. Database contains tabulations for monthly and annual means (mu), standard deviations (sigma) and skewness of wind and thermodynamic variables. Wind, Thermodynamic, Humidity and Hydrostatic parameters 1 km resolution interval from 0-30 km 2 km resolution interval 30-70 km Multiple revisions of the CCAFS RRA database have been developed since initial RRA published in 1963. 1971, 1983, 2006 Space Shuttle program utilized 1983 version for use in deriving "hot" and "cold" atmospheres, atmospheric density dispersions for use in vehicle certification analyses and selection of atmospheric thermodynamic profiles for use in vehicle ascent design and certification analyses. During STS-114 launch preparations in July 2005 atmospheric density observations between 50-80 kft exceeded density limits used for aerodynamic ascent heating constraints in vehicle certification analyses. Mission specific analyses were conducted and concluded that the density bias resulted in small changes to heating rates and integrated heat loading on the vehicle. In 2001, the Air Force Combat Climatology Center began developing an updated RRA for CCAFS.

Decker, Ryan↗

Crustal radiogenic heat production and the selective survival of ancient continental crust

It is pointed out that the oldest terrestrial rocks have so far revealed no evidence of the impact phase of Earth evolution. This observation suggests that processes other than impact were dominant at the time of stabilization of these units. However, a use of the oldest terrestrial rocks as a sample of the early terrestrial crust makes it necessary to consider the possibility that these rocks may represent a biased sample. In the present study, the global continental heat flow data set is used to provide further evidence that potassium, uranium, and thorium abundances are, on the average, low in surviving Archean crust relative to younger continental crust. An investigation is conducted of the implications of relatively low crustal radiogenic heat production to the stabilization of early continental crust, and possible Archean crustal stabilization models are discussed.

Morgan, P.↗