Search NASA⌕ Search

SEARCH · Search NASA

Results for “Source Physics Experiment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Experimental Investigation of Active Feedback Control of Turbulent Transport in a Magnetized Plasma

A new and unique basic plasma science laboratory device - the HelCat device (HELicon-CAThode) - has been constructed and is operating at the University of New Mexico. HelCat is a 4 m long, 0.5 m diameter device, with magnetic field up to 2.2 kG, that has two independent plasmas sources - an RF helicon source, and a thermionic cathode. These two sources, which can operate independently or simultaneously, are capable of producing plasmas with a wide range of parameters and turbulence characteristics, well suited to a variety of basic plasma physics experiments. An extensive set of plasma diagnostics is also operating. Experiments investigating the active feedback control of turbulent transport of particles and heat via electrode biasing to affect plasma ExB flows are underway, and ongoing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Uncertainty Quantification Techniques of SCALE/TSUNAMI

The Standardized Computer Analysis for Licensing Evaluation (SCALE) code system developed at Oak Ridge National Laboratory (ORNL) includes Tools for Sensitivity and Uncertainty Analysis Methodology Implementation (TSUNAMI). The TSUNAMI code suite can quantify the predicted change in system responses, such as k eff , reactivity differences, or ratios of fluxes or reaction rates, due to changes in the energy-dependent, nuclide-reaction-specific cross-section data. Where uncertainties in the neutron cross-section data are available, the sensitivity of the system to the cross-section data can be applied to propagate the uncertainties in the cross-section data to an uncertainty in the system response. Uncertainty quantification is useful for identifying potential sources of computational biases and highlighting parameters important to code validation. Traditional validation techniques often examine one or more average physical parameters to characterize a system and identify applicable benchmark experiments. However, with TSUNAMI correlation coefficients are developed by propagating the uncertainties in neutron cross-section data to uncertainties in the computed responses for experiments and safety applications through sensitivity coefficients. The bias in the experiments, as a function of their correlation coefficient with the intended application, is extrapolated to predict the bias and bias uncertainty in the application through trending analysis or generalized linear least squares techniques, often referred to as 'data adjustment.' Even with advanced tools to identify benchmark experiments, analysts occasionally find that the application models include some feature or material for which adequately similar benchmark experiments do not exist to support validation. For example, a criticality safety analyst may want to take credit for the presence of fission products in spent nuclear fuel. In such cases, analysts sometimes rely on 'expert judgment' to select an additional administrative margin to account for gap in the validation data or to conclude that the impact on the calculated bias and bias uncertainty is negligible. As a result of advances in computer programs and the evolution of cross-section covariance data, analysts can use the sensitivity and uncertainty analysis tools in the TSUNAMI codes to estimate the potential impact on the application-specific bias and bias uncertainty resulting from nuclides not represented in available benchmark experiments. This paper presents the application of methods described in a companion paper.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Signals of a New Gauge Boson from IceCube and Muon $g-2$

A $Z'$ boson associated with a broken $U(1)_{L_{\mu} - L_{\tau}}$ gauge symmetry offers an economical solution to the long-standing $g_\mu-2$ anomaly, confirmed and strengthened by recent measurements at Fermilab. Here, we revisit the impact of such a $Z'$ on the spectrum of high-energy astrophysical neutrinos, as measured by the IceCube experiment. This spectrum has been observed to exhibit a dip-like feature at $E_{\nu} \sim 0.2-1 \, {\rm PeV}$, which could plausibly arise from the physics of the sources themselves, but could also be the consequence of high-energy neutrinos resonantly scattering with the cosmic neutrino background, mediated by a $Z'$ with a mass on the order of $m_{Z'} \sim 10 \, {\rm MeV}$. In this study, we calculate the impact of such a $Z'$ on the high-energy neutrino spectrum for a variety of model parameters and source distributions. For couplings that can resolve the $g_{\mu}-2$ anomaly, we find that this model could self-consistently produce a spectral feature that is consistent with IceCube's measurement, in particular if the neutrinos observed by IceCube predominantly originate from high-redshift sources.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An FFAG Accelerator for the intensity frontier

The next generation of high-energy physics experiments requires high intensity protons in the multi-GeV energy range for efficient production of secondary beams. The Fermilab long-term future requires an 8 GeV proton source to feed the Main I njector for a 2 MW neutrino beam source in the immediate future and to provide 4 MW pulsed proton beam for a future neutrino factory or muon collider. We note that a 3GeV cw linac matched to a 3--8 GeV FFAG ring could provide beam for both of these missio n needs, as well as the cw 3 GeV experiments, and would be a natural and affordable scenario. We present details of possible scenarios and outline future design and research directions.

43 PARTICLE ACCELERATORS↗

The COHERENT Experiment at the Spallation Neutron Source

The COHERENT collaboration's primary objective is to measure coherent elastic neutrino- nucleus scattering (CEvNS) using the unique, high-quality source of tens-of-MeV neutrinos provided by the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). In spite of its large cross section, the CEvNS process has never been observed, due to tiny energies of the resulting nuclear recoils which are out of reach for standard neutrino detectors. The measurement of CEvNS has now become feasible, thanks to the development of ultra-sensitive technology for rare decay and weakly-interacting massive particle (dark matter) searches. The CEvNS cross section is cleanly predicted in the standard model; hence its measurement provides a standard model test. It is relevant for supernova physics and supernova-neutrino detection, and enables validation of dark-matter detector background and detector-response models. In the long term, precision measurement of CEvNS will address questions of nuclear structure. COHERENT will deploy multiple detector technologies in a phased approach: a 14-kg CsI[Na] scintillating crystal, 15 kg of p-type point-contact germanium detectors, and 100 kg of liquid xenon in a two-phase time projection chamber. Following an extensive background measurement campaign, a location in the SNS basement has proven to be neutron-quiet and suitable for deployment of the COHERENT detector suite. The simultaneous deployment of the three COHERENT detector subsystems will test the N=2 dependence of the cross section and ensure an unambiguous discovery of CEvNS. This document describes concisely the COHERENT physics motivations, sensitivity and plans for measurements at the SNS to be accomplished on a four-year timescale.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Kinetic solutions for electrons in multi-cusp ion source

Some analytical kinetic solutions are obtained for the primary and plasma electrons in multi-cusp ion source. The characteristics based on these solutions are discussed, such as frictional coefficient, collision frequency, electron current, electron diffusion, electron density, and electrical conductivity. A code based on one of these solutions is developed to discuss the plasma electrons diffusion; the simulation results are qualitatively consistent with our current experiences.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Opportunities for retrieval and tool augmented large language models in scientific facilities

Upgrades to advanced scientific user facilities such as next-generation x-ray light sources, nanoscience centers, and neutron facilities are revolutionizing our understanding of materials across the spectrum of the physical sciences, from life sciences to microelectronics. However, these facility and instrument upgrades come with a significant increase in complexity. Driven by more exacting scientific needs, instruments and experiments become more intricate each year. This increased operational complexity makes it ever more challenging for domain scientists to design experiments that effectively leverage the capabilities of and operate on these advanced instruments. Large language models (LLMs) can perform complex information retrieval, assist in knowledge-intensive tasks across applications, and provide guidance on tool usage. Using x-ray light sources, leadership computing, and nanoscience centers as representative examples, we describe preliminary experiments with a Context-Aware Language Model for Science (CALMS) to assist scientists with instrument operations and complex experimentation. With the ability to retrieve relevant information from facility documentation, CALMS can answer simple questions on scientific capabilities and other operational procedures. With the ability to interface with software tools and experimental hardware, CALMS can conversationally operate scientific instruments. By making information more accessible and acting on user needs, LLMs could expand and diversify scientific facilities’ users and accelerate scientific output.

97 MATHEMATICS AND COMPUTING↗

Program of Fundamental-Interaction Research for the Ultracold-Neutron Source at the the WWR-M Reactor

The use of ultracold neutrons opens unique possibilities for studying fundamental interactions in particles physics. Searches for the neutron electric dipole moment are aimed at testing models of CP violation. A precise measurement of the neutron lifetime is of paramount importance for cosmology and astrophysics. Considerable advances in these realms can be made with the aid of a new ultracold-neutron (UCN) supersource presently under construction at Petersburg Nuclear Physics Institute. With this source, it would be possible to obtain an UCN density approximately 100 times as high as that at currently the best UCN source at the high-flux reactor of the Institute Laue–Langevin (ILL, Grenoble, France). To date, the design and basic elements of the source have been prepared, tests of a full-scale source model have been performed, and the research program has been developed. It is planned to improve accuracy in measuring the neutron electric dipole moment by one order of magnitude to a level of 10{sup −27} to 10{sup −28}e cm. This is of crucial importance for particle physics. The accuracy in measuring the neutron lifetime can also be improved by one order of magnitude. Finally, experiments that would seek neutron–antineutron oscillations by employing ultracold neutrons will become possible upon reaching an UCN density of 10{sup 3} to 10{sup 4} cm{sup −3}. The current status of the source and the proposed research program are discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

A versatile, pulsed anion source utilizing plasma-entrainment: Characterization and applications

A novel pulsed anion source has been developed, using plasma entrainment into a supersonic expansion. A pulsed discharge source perpendicular to the main gas expansion greatly reduces unwanted “heating” of the main expansion, a major setback in many pulsed anion sources in use today. The design principles and construction information are described and several examples demonstrate the range of applicability of this anion source. Large OH{sup −}(Ar){sub n} clusters can be generated, with over 40 Ar solvating OH{sup −}. The solvation energy of OH{sup −}(Ar){sub n}, where n = 1-3, 7, 12, and 18, is derived from photoelectron spectroscopy and shows that by n = 12-18, each Ar is bound by about 10 meV. In addition, cis– and trans– HOCO{sup −} are generated through rational anion synthesis (OH{sup −} + CO + M → HOCO{sup −} + M) and the photoelectron spectra compared with previous results. These results, along with several further proof-of-principle experiments on solvation and transient anion synthesis, demonstrate the ability of this source to efficiently produce cold anions. With modifications to two standard General Valve assemblies and very little maintenance, this anion source provides a versatile and straightforward addition to a wide array of experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Propagating molecular rotational coherences through single-frequency pulses in the strong field regime

In the weak-field limit in which microwave spectroscopy is typically carried out, an application of a single-frequency pulse that is resonant with a molecular transition will create a coherence between the pair of states involved in the rotational transition, producing a free-induction decay (FID) that, after Fourier transform, produces a molecular signal at that same resonance frequency. With the advent of chirped-pulse Fourier transform microwave methods, the high-powered amplifiers needed to produce broadband microwave spectra also open up other experiments that probe the molecular response in the high-field regime. This paper describes a series of experiments involving resonant frequency pulses interrogating jet-cooled molecules under conditions of sufficient power to Rabi oscillate the two-state system through many Rabi cycles. The Fourier-transformed FID shows coherent signal not only at the applied resonant frequency but also at a series of transitions initially connected to the original one by sharing an upper or lower level with it. As the duration of the single-frequency excitation is increased from 250 to 1500 ns, the number of observed off-resonant, but dipole-allowed, molecular coherences grow. The phenomenon is quite general, having been demonstrated in Z-phenylvinylnitrile, E-phenylvinylnitrile (E-PVN), benzonitrile, guaiacol, and 4-pentynenitrile. In E-PVN, the highest power/longest pulse duration, coherent signal is also present at energetically nearby but not directly connected transitions. Even in molecular samples containing more than one independent species, only transitions due to the single species responsible for the original resonant transition are present. Here, we develop a time-dependent model of the molecular/photon system and use it in conjunction with the experiment to test possible sources of the phenomenon.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bayesian Spectral Moment Estimation and Uncertainty Quantification

We present a Bayesian spectral fitting method developed for spectroscopic data analysis, particularly (but not solely) in the context of fusion energy research. The presented techniques are particularly valuable to estimating moments and corresponding uncertainties whenever the spectra result from line-integrated measurements in nonuniform plasmas, for which the approximation of atomic line shapes being ideal Gaussians gives poor estimates. We decompose multiple, potentially overlapping spectral lines into a sum of Gauss-Hermite polynomials, whose properties allow efficient truncation and uncertainty quantification, often with only three free parameters per atomic emission line. Tests with both synthetic and experimental data demonstrate the effectiveness and robustness where more standard nonlinear fitting routines may experience difficulties. A parallelized version of our implementation is publicly released under an open source license.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Generation, transmission, and detection of terahertz photons on an electrically driven single chip

We demonstrate single photon counting of terahertz (THz) waves transmitted from a local THz point source through a coplanar two-wire waveguide on a GaAs/AlGaAs single heterostructure crystal. In the electrically driven all-in-one chip, quantum Hall edge transport is used to achieve a noiseless injection current for a monochromatic point source of THz fields. The local THz fields are coupled to a coplanar two-wire metal waveguide and transmitted over a macroscopic scale greater than the wavelength (38 μm in GaAs). THz waves propagating on the waveguide are counted as individual photons by a quantum-dot single-electron transistor on the same chip. Photon counting on integrated high-frequency circuits will open the possibilities for on-chip quantum optical experiments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Laser plasma x-ray source for ultrafast time-resolved x-ray absorption spectroscopy

We describe a laser-driven x-ray plasma source designed for ultrafast x-ray absorption spectroscopy. The source is comprised of a 1 kHz, 20 W, femtosecond pulsed infrared laser and a water target. We present the x-ray spectra as a function of laser energy and pulse duration. Additionally, we investigate the plasma temperature and photon flux as we vary the laser energy. We obtain a 75 μm FWHM x-ray spot size, containing ~10 6 photons/s, by focusing the produced x-rays with a polycapillary optic. Since the acquisition of x-ray absorption spectra requires the averaging of measurements from >10 7 laser pulses, we also present data on the source stability, including single pulse measurements of the x-ray yield and the x-ray spectral shape. In single pulse measurements, the x-ray flux has a measured standard deviation of 8%, where the laser pointing is the main cause of variability. Further, we show that the variability in x-ray spectral shape from single pulses is low, thus justifying the combining of x-rays obtained from different laser pulses into a single spectrum. Finally, we show a static x-ray absorption spectrum of a ferrioxalate solution as detected by a microcalorimeter array. Altogether, our results demonstrate that this water-jet based plasma source is a suitable candidate for laboratory-based time-resolved x-ray absorption spectroscopy experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MTV-G experiment: Probing non-standard strong gravitational field at nuclear scale using geodetic precession

A new experiment named MTV-G, probing a large electron spin-precession due to a possible strong gravitational field, which predicted by large extra dimension model, is started at TRIUMF from 2011. In an electron-nuclear scattering experiment, a strong gravitational field is tested as a large spin precession effect caused by geodetic precession predicted by general relativity theory as a result of a warped space-time around nuclei. Experimental design using spin polarized electron source and Mott-spin analyzer, commissioning experiment and the preliminary results are described.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simulations of Hyperthermal Oxygen Beam Exposures

Pulsed sources of hyper-thermal O-atoms are now being extensively used to simulate low-earth orbit (LEO) surface exposure environments. The peak flux of these sources is many orders of magnitude larger than the corresponding LEO flux. Although it is desirable to accelerate the test by using higher fluxes than found in LEO, even commonly used fluxes are large enough to produce multi-collision effects by causing a build-up of gas at the sample surface. In this paper we characterize the physical consequences to the experiment using the direct simulation Monte Carlo (DSMC) method, DSMC allows us to extract the distributions of energy and impact angle for the O-atoms that reach the surface, and to record how strongly the gas build-up at the target assembly deflects flux from downstream instrumentation. By considering a range of source fluxes, we determine the onset conditions and severity of these multi-collision effects. We find that even at common experimental fluxes with a normally incident beam string a flat surface sample, the energy distribution of incident O-atoms broadens and develops a significant low-energy tail. The angular distributions also broaden significantly. The number of O-atoms that reach downstream instrumentation is decreased by approximately 50%. These simulations will aid in the calibration of ground-based O-atom measurements,a nd provide a model for the energy and angular distributions of O-atoms that actually impinge on surface samples.

Finchum, A.↗

DSMC Simulations of Hyperthermal Oxygen Beam Exposures

Pulsed sources of hyper-thermal O-atoms are now being extensively used to simulate low-earth orbit (LEO) surface exposure environments. The peak flux of these sources is many orders of magnitude larger than the corresponding LEO flux. Although it is desirable to accelerate the test by using higher fluxes than found in LEO, even commonly used fluxes are large enough to produce multi-collision effects by causing a build-up of gas at the sample surface. In this paper we characterize the physical consequences to the experiment using the direct simulation Monte Carlo (DSMC) method. DSMC allows us to extract the distributions of energy and impact angle for the O-atoms that reach the surface, and to record how strongly the gas build-up at the target assembly deflects flux from downstream instrumentation. By considering a range of source fluxes, we determine the onset conditions and severity of these multi-collision effects. We find that even at common experimental fluxes with a normally incident beam striking a flat surface sample, the energy distribution of incident O-atoms broadens and develops a significant low-energy tail. The angular distributions also broaden significantly. The number of O-atoms that reach downstream instrumentation is decreased by approximately 50%. These simulations will aid in the calibration of ground-based O-atom measurements, and provide a model for the energy and angular distributions of O-atoms that actually impinge on surface samples.

Cline, Jason A.↗

Comparative study of 0° X-cut and Y + 36°-cut lithium niobate high-voltage sensing

A comparison study between Y + 36° and 0° X-cut lithium niobate (LiNbO{sub 3}) was performed to evaluate the influence of crystal cut on the acoustic propagation to realize a piezoelectric high-voltage sensor. The acoustic time-of-flight for each crystal cut was measured when applying direct current (DC), alternating current (AC), and pulsed voltages. Results show that the voltage-induced shift in the acoustic wave propagation time scaled quadratically with voltage for DC and AC voltages applied to X-cut crystals. For the Y + 36° crystal, the voltage-induced shift scales linearly with DC voltages and quadratically with AC voltages. When applying 5 μs voltage pulses to both crystals, the voltage-induced shift scaled linearly with voltage. For the Y + 36° cut, the voltage-induced shift from applying DC voltages ranged from 10 to 54 ps and 35 to 778 ps for AC voltages at 640 V over the frequency range of 100 Hz–100 kHz. Using the same conditions as the Y + 36° cut, the 0° X-cut crystal sensed a shift of 10–273 ps for DC voltages and 189–813 ps for AC voltage application. For 5 μs voltage pulses, the 0° X-cut crystal sensed a voltage induced shift of 0.250–2 ns and the Y + 36°-cut crystal sensed a time shift of 0.115–1.6 ns. This suggests a frequency sensitive response to voltage where the influence of the crystal cut was not a significant contributor under DC, AC, or pulsed voltage conditions. The measured DC data were compared to a 1-D impedance matrix model where the predicted incremental length changed as a function of voltage. When the voltage source error was eliminated through physical modeling from the uncertainty budget, the combined uncertainty of the sensor (within a 95% confidence interval) decreased to 0.0033% using a Y + 36°-cut crystal and 0.0032% using an X-cut crystal for all the voltage conditions used in this experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗